{"id":45333,"date":"2025-10-08T17:54:42","date_gmt":"2025-10-08T17:54:42","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/a-comparison-of-sample-preparation-techniques-for-drugs-of-abuse-in-oral-fluid-japan\/"},"modified":"2026-01-14T19:22:14","modified_gmt":"2026-01-14T19:22:14","slug":"a-comparison-of-sample-preparation-techniques-for-drugs-of-abuse-in-oral-fluid-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/cfan4466-ja\/a-comparison-of-sample-preparation-techniques-for-drugs-of-abuse-in-oral-fluid-japan","title":{"rendered":"\u53e3\u8154\u6db2\u4e2d\u306e\u85ac\u7269\u5206\u6790\u306b\u304a\u3051\u308b\u9769\u65b0\uff1aSALLE\u3068SLE\u3067\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3092\u52b9\u7387\u5316"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e71\u7528\u85ac\u7269\u306e\u691c\u67fb\u306f\u3001\u6bd2\u7269\u5b66\u3084\u8077\u5834\u3067\u306e\u85ac\u7269\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u5206\u91ce\u3067\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u3066\u3044\u307e\u3059\u3002\u5f93\u6765\u306f\u8840\u6db2\u3084\u5c3f\u304c\u6a19\u6e96\u7684\u306a\u691c\u4f53\u3068\u3057\u3066\u7528\u3044\u3089\u308c\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u3053\u308c\u3089\u306e\u63a1\u53d6\u306f\u8eab\u4f53\u3078\u306e\u8ca0\u62c5\u304c\u5927\u304d\u304f\u3001\u88ab\u9a13\u8005\u306b\u3068\u3063\u3066\u3082\u30b9\u30c8\u30ec\u30b9\u3068\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u3046\u3057\u305f\u80cc\u666f\u304b\u3089\u3001\u8fd1\u5e74\u306f\u53e3\u8154\u6db2\uff08\u553e\u6db2\uff09\u3092\u7528\u3044\u305f\u691c\u67fb\u304c\u6ce8\u76ee\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u53e3\u8154\u6db2\u306f\u3001\u7c21\u5358\u306a\u65b9\u6cd5\u3067\u88ab\u9a13\u8005\u306b\u30b9\u30c8\u30ec\u30b9\u3092\u4e0e\u3048\u305a\u63a1\u53d6\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u304b\u3089\u3001\u3088\u308a\u591a\u304f\u306e\u73fe\u5834\u3067\u5229\u7528\u304c\u5e83\u304c\u3063\u3066\u3044\u307e\u3059\u3002\u4e00\u65b9\u3067\u3001\u53e3\u8154\u6db2\u691c\u67fb\u306b\u306f\u8ab2\u984c\u3082\u3042\u308a\u307e\u3059\u3002\u7279\u306b\u3001\u63a1\u53d6\u306b\u7528\u3044\u308b\u88c5\u7f6e\u306e\u7de9\u885d\u6db2\u306b\u306f\u4fdd\u5b58\u6599\u3084\u754c\u9762\u6d3b\u6027\u5264\u3068\u3044\u3063\u305f\u6dfb\u52a0\u5264\u304c\u542b\u307e\u308c\u3066\u304a\u308a\u3001\u3053\u308c\u3089\u304c\u5206\u6790\u306b\u5e72\u6e09\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u6210\u5206\u3092\u9664\u53bb\u3059\u308b\u524d\u51e6\u7406\u3068\u3057\u3066\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u5de5\u7a0b\u304c\u5fc5\u8981\u3067\u3059\u304c\u3001\u3053\u306e\u5de5\u7a0b\u306b\u306f\u73fe\u72b6\u3001\u591a\u304f\u306e\u6642\u9593\u3068\u624b\u9593\u304c\u304b\u304b\u3063\u3066\u3044\u308b\u306e\u304c\u5b9f\u60c5\u3067\u3059\u3002\u305d\u3053\u3067\u3001\u4eca\u56de\u306e\u7814\u7a76\u3067\u306f\u3001LC-MS\/MS\u3092\u7528\u3044\u305f\u53e3\u8154\u6db2\u4e2d\u306e\u4e71\u7528\u85ac\u7269\u304a\u3088\u3073\u65b0\u898f\u7cbe\u795e\u6d3b\u6027\u7269\u8cea\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u5869\u6790\u652f\u63f4\u6db2\u6db2\u62bd\u51fa\uff08SALLE\uff09\u3001\u4fdd\u6301\u578b\u6db2\u6db2\u62bd\u51fa\uff08SLE\uff09\u3001\u304a\u3088\u3073\u5e0c\u91c8\u6ce8\u5165\u3068\u3044\u30463\u3064\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6280\u8853\u3092\u6bd4\u8f03\u3057\u3001SPE\u5de5\u7a0b\u306e\u6642\u9593\u77ed\u7e2e\u3092\u76ee\u6307\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7c21\u4fbf\u304b\u3064\u88ab\u9a13\u8005\u306b\u30b9\u30c8\u30ec\u30b9\u3092\u4e0e\u3048\u305a\u306b\u63a1\u53d6\u53ef\u80fd\u306a\u305f\u3081\u3001\u3088\u308a\u591a\u304f\u306e\u73fe\u5834\u3067\u5229\u7528\u304c\u5e83\u304c\u308b\u53e3\u8154\u6db2\u691c\u67fb[1]\u3067\u3059\u304c\u3001\u53e3\u8154\u6db2\u306f\u3001\u553e\u6db2\u305d\u306e\u3082\u306e\u3060\u3051\u3067\u306a\u304f\u3001\u53e3\u8154\u5185\u306e\u7d30\u83cc\u3084\u98df\u3079\u304b\u3059\u306a\u3069\u3082\u542b\u3080\u8907\u96d1\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3067\u3059[2]\u3002\u8840\u6db2\u3068\u826f\u597d\u306a\u85ac\u7269\u6fc3\u5ea6\u306e\u76f8\u95a2\u304c\u5f97\u3089\u308c\u308b\u4e00\u65b9\u3067\u3001\u98f2\u98df\u3084\u55ab\u7159\u306a\u3069\u3001\u63a1\u53d6\u524d\u306e\u751f\u6d3b\u7fd2\u6163\u304c\u691c\u67fb\u7d50\u679c\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u70b9\u306b\u306f\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059[1]\u3002\u307e\u305f\u3001\u5c3f\u691c\u67fb\u3067\u61f8\u5ff5\u3055\u308c\u308b\u3088\u3046\u306a\u3001\u691c\u4f53\u3078\u306e\u7570\u7269\u6df7\u5165\uff08\u4e0d\u7d14\u7269\uff09\u3084\u6c34\u306a\u3069\u306b\u3088\u308b\u5e0c\u91c8\u3001\u4ed6\u4eba\u306e\u5c3f\u3068\u3059\u308a\u66ff\u3048\u308b\u3068\u3044\u3063\u305f\u4e0d\u6b63\u306e\u30ea\u30b9\u30af\u304c\u6bd4\u8f03\u7684\u5c11\u306a\u3044\u3053\u3068\u3082\u3001\u53e3\u8154\u6db2\u691c\u67fb\u306e\u5229\u70b9\u306e\u3072\u3068\u3064\u3067\u3059[1,2]\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u53e3\u8154\u6db2\u3092\u7528\u3044\u305f\u85ac\u7269\u5206\u6790\u3067\u306f\u3001\u901a\u5e38\u3001\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u3084\u5e0c\u91c8\u6ce8\u5165\u6cd5\u304c\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3068\u3057\u3066\u7528\u3044\u3089\u308c\u307e\u3059\u3002\u53e3\u8154\u6db2\u81ea\u4f53\u306f\u6bd4\u8f03\u7684\u4f5c\u696d\u3057\u3084\u3059\u3044\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3067\u3059\u304c\u3001\u63a1\u53d6\u30ad\u30c3\u30c8\u306e\u7de9\u885d\u6db2\u306b\u542b\u307e\u308c\u308b\u6dfb\u52a0\u5264\u304c\u554f\u984c\u3067\u3059\u3002\u7de9\u885d\u6db2\u306f\u30b5\u30f3\u30d7\u30eb\u4fdd\u5b58\u3068\u5fae\u751f\u7269\u306e\u5897\u6b96\u6291\u5236\u306b\u5fc5\u8981\u306a\u3082\u306e\u3067\u3059\u304c\u3001\u7de9\u885d\u6db2\u306b\u542b\u307e\u308c\u308b\u6dfb\u52a0\u5264\u306f\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u52b9\u679c\u3092\u5f15\u304d\u8d77\u3053\u3057\u3001\u5206\u6790\u30ab\u30e9\u30e0\u306e\u5bff\u547d\u3092\u7e2e\u3081\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002SPE\u306e\u65b9\u304c\u7de9\u885d\u6db2\u306e\u5f71\u97ff\u3092\u8efd\u6e1b\u3067\u304d\u307e\u3059\u304c\u3001\u624b\u9806\u304c\u8907\u96d1\u3067\u6642\u9593\u304c\u304b\u304b\u308b\u3068\u3044\u3046\u30c7\u30e1\u30ea\u30c3\u30c8\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9f\u969b\u306b\u85ac\u7269\u5206\u6790\u3092\u884c\u3046\u30e9\u30dc\u304c\u6c42\u3081\u308b\u306e\u306f\u6642\u9593\u304c\u304b\u304b\u3089\u306a\u3044\u3001\u52b9\u679c\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3067\u3059\u3002\u305d\u3053\u3067\u3001\u3053\u306e\u5b9f\u9a13\u3067\u306f\u3001\u4fdd\u6301\u578b\u6db2\u6db2\u62bd\u51fa\uff08SLE\uff09\u3068\u5869\u6790\u652f\u63f4\u6db2\u6db2\u62bd\u51fa\uff08SALLE\uff09\u304a\u3088\u3073\u3001\u5358\u7d14\u306a\u5e0c\u91c8\u6ce8\u5165\u6cd5\u3068\u3044\u30463\u7a2e\u985e\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306b\u3064\u3044\u3066\u6bd4\u8f03\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u306a\u304a\u3001\u5e0c\u91c8\u6ce8\u5165\u6cd5\u3067\u306f\u691c\u51fa\u611f\u5ea6\u304c\u8457\u3057\u304f\u4f4e\u304f\u3001\u5b9a\u91cf\u7684\u8a55\u4fa1\u304c\u56f0\u96e3\u3060\u3063\u305f\u305f\u3081\u3001\u4ee5\u964d\u306e\u691c\u8a0e\u5bfe\u8c61\u304b\u3089\u9664\u5916\u3057\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001SLE\u304a\u3088\u3073SALLE\u3092\u63a1\u7528\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u3067\u306f\u826f\u597d\u306a\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u5f97\u3089\u308c\u3001\u7cbe\u5ea6\u3001\u518d\u73fe\u6027\u3001\u76f4\u7dda\u6027\u306e\u7d50\u679c\u306f\u826f\u597d\u3067\u3001\u6709\u7528\u6027\u304c\u3042\u308b\u3068\u8a55\u4fa1\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9f\u9a13<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\u6821\u6b63\u7528\u6a19\u6e96\u8a66\u6599\u3068\u54c1\u8cea\u7ba1\u7406\uff08QC\uff09\u7528\u6a19\u6e96\u8a66\u6599\u306e\u8abf\u88fd<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3010\u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db2\u3011<br>10,000, 5000, 2500, 1000, 500, 100, 50, 20 ng\/mL\u306e\u6fc3\u5ea6\u306b\u306a\u308b\u3088\u3046\u306b\u300110,000 ng\/mL\u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u5e0c\u91c8\u3057\u3001\u8abf\u88fd<br>\u3010\u54c1\u8cea\u7ba1\u7406\uff08QC\uff09\u7528\u6a19\u6e96\u6eb6\u6db2\u3011<br>50, 650, 1500, 6500 ng\/mL\u306e\u6fc3\u5ea6\u306b\u306a\u308b\u3088\u3046\u306b\u300110,000 ng\/mL\u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u5e0c\u91c8\u3057\u3001\u8abf\u88fd<br>\u3010\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u3011<br><strong>Table I<\/strong>\u306b\u793a\u3057\u305f\u5206\u6790\u6210\u5206\u3092\u4f7f\u7528\u3057\u3066\u3001100 ng\/mL\u306e\u6fc3\u5ea6\u306b\u306a\u308b\u3088\u3046\u306b\u8abf\u88fd<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u8a18\u306e\u65b9\u6cd5\u3067\u8abf\u88fd\u3057\u305f\u5404\u6a19\u6e96\u6eb6\u6db2100 \u00b5L\u3092\u5408\u6210\u53e3\u8154\u6db2\uff08UTAK\u793e\u88fd\uff09900 \u00b5L\u306b\u52a0\u3048\u306610\u500d\u306b\u5e0c\u91c8\u3057\u3001\u6821\u6b63\u7528\u304a\u3088\u3073QC\u7528\u306e\u6a19\u6e96\u8a66\u6599\u3092\u4f5c\u88fd\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u5f8c\u3001\u4e0b\u8a18\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> \u5185\u90e8\u6a19\u6e96\u7269\u8cea\u304a\u3088\u3073MRM\u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5185\u90e8\u6a19\u6e96\u7269\u8cea<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Precursor Ion<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Product Ion 1<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Methamphetamine-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">155.6<\/td><td class=\"has-text-align-center\" data-align=\"center\">92.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Norfentanyl-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">238.6<\/td><td class=\"has-text-align-center\" data-align=\"center\">55.2<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Oxazepam-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">292.3<\/td><td class=\"has-text-align-center\" data-align=\"center\">246.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">LSD-D3<\/td><td class=\"has-text-align-center\" data-align=\"center\">327.2<\/td><td class=\"has-text-align-center\" data-align=\"center\">179.9<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">MDMA-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">199.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">107.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Ketamine-D4<\/td><td class=\"has-text-align-center\" data-align=\"center\">242.5<\/td><td class=\"has-text-align-center\" data-align=\"center\">129.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">7-Aminoclonazepam-D4<\/td><td class=\"has-text-align-center\" data-align=\"center\">290.4<\/td><td class=\"has-text-align-center\" data-align=\"center\">121.0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">6-Acetylmorphine-D3<\/td><td class=\"has-text-align-center\" data-align=\"center\">331.3<\/td><td class=\"has-text-align-center\" data-align=\"center\">165.0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">PCP-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">249.4<\/td><td class=\"has-text-align-center\" data-align=\"center\">96.2<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Fentanyl-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">342.2<\/td><td class=\"has-text-align-center\" data-align=\"center\">105.0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">EDDP-D3<\/td><td class=\"has-text-align-center\" data-align=\"center\">280.7<\/td><td class=\"has-text-align-center\" data-align=\"center\">234.2<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hydromorphone-D3<\/td><td class=\"has-text-align-center\" data-align=\"center\">289.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">184.9<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Methadone-D3<\/td><td class=\"has-text-align-center\" data-align=\"center\">313.1<\/td><td class=\"has-text-align-center\" data-align=\"center\">105.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Buprenorphine-D4<\/td><td class=\"has-text-align-center\" data-align=\"center\">471.9<\/td><td class=\"has-text-align-center\" data-align=\"center\">243.2<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Temazepam-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">306.3<\/td><td class=\"has-text-align-center\" data-align=\"center\">260.0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Norbuprenorphine-D4<\/td><td class=\"has-text-align-center\" data-align=\"center\">417.6<\/td><td class=\"has-text-align-center\" data-align=\"center\">186.9<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Morphine-D3<\/td><td class=\"has-text-align-center\" data-align=\"center\">289.6<\/td><td class=\"has-text-align-center\" data-align=\"center\">164.9<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Oxycodone-D6<\/td><td class=\"has-text-align-center\" data-align=\"center\">322.4<\/td><td class=\"has-text-align-center\" data-align=\"center\">247.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Oxymorphone-D3<\/td><td class=\"has-text-align-center\" data-align=\"center\">305.4<\/td><td class=\"has-text-align-center\" data-align=\"center\">230.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Nordiazepam-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">276.3<\/td><td class=\"has-text-align-center\" data-align=\"center\">140.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Alprazolam-D5<\/td><td class=\"has-text-align-center\" data-align=\"center\">314.2<\/td><td class=\"has-text-align-center\" data-align=\"center\">286.0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Isotonitazene-D7<\/td><td class=\"has-text-align-center\" data-align=\"center\">418.2<\/td><td class=\"has-text-align-center\" data-align=\"center\">100.0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Cocaine-D3<\/td><td class=\"has-text-align-center\" data-align=\"center\">307.3<\/td><td class=\"has-text-align-center\" data-align=\"center\">185.3<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Lidocaine-D10<\/td><td class=\"has-text-align-center\" data-align=\"center\">245.2<\/td><td class=\"has-text-align-center\" data-align=\"center\">64.0<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">delta-9-THC-D3<\/td><td class=\"has-text-align-center\" data-align=\"center\">318.2<\/td><td class=\"has-text-align-center\" data-align=\"center\">193.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Gabapentin-D10<\/td><td class=\"has-text-align-center\" data-align=\"center\">182.0<\/td><td class=\"has-text-align-center\" data-align=\"center\">147.2<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5<\/h3>\n\n\n\n<h4 class=\"wp-block-heading\">1. \u5e0c\u91c8\u6ce8\u5165\u6cd5<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u25e6\u3000\u5b9f\u969b\u306e\u6fc3\u5ea6\u306b\u8fd1\u3044\u6fc3\u5ea6\u3067\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3046\u305f\u3081\u306b\u6821\u6b63\u7528\u6a19\u6e96\u8a66\u6599\u304a\u3088\u3073QC\u7528\u6a19\u6e96\u8a66\u6599\u3001\u54041 mL\u306bQuantisal\u7de9\u885d\u6db2\uff08Immunalysis\u793e\u88fd\uff093 mL\u3092\u6dfb\u52a0<br>\u25e6\u3000\u3053\u306e\u7de9\u885d\u6db2\u6dfb\u52a0\u6e08\u307f\u306e\u6a19\u6e96\u8a66\u6599\u305d\u308c\u305e\u308c100 \u00b5L\u30922 mL\u5bb9\u91cf\u306e\u5fae\u91cf\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6\u306b\u5165\u308c\u305f\u5f8c\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea20 \u00b5L\u3092\u6dfb\u52a0\u3057\u300110\u79d2\u9593\u64b9\u62cc\uff08\u4ee5\u964d\u3053\u306e\u72b6\u614b\u3092\u30b5\u30f3\u30d7\u30eb\u3068\u3059\u308b\uff09<br>\u25e6\u3000\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u30010.1%\u30ae\u9178\u6c34\u6eb6\u6db2:0.1%\u30ae\u9178\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u6db2\u309290:10\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db2460 \u00b5L\u3092\u6dfb\u52a0\u3057\u3001\u518d\u5ea6\u64b9\u62cc<br>\u25e6\u3000\u30a4\u30f3\u30b5\u30fc\u30c8\u4ed8\u304d\u306eLC\u30d0\u30a4\u30a2\u30eb\uff082.0 mL\u8910\u8272\u30b7\u30e7\u30fc\u30c8\u30ad\u30e3\u30c3\u30d7\u30d0\u30a4\u30a2\u30eb\uff1acat.# 21142\u300150 \u00b5L\u30a4\u30f3\u30b5\u30fc\u30c8\uff1acat.# 24513\uff09\u306b\u8a66\u6599\u3092\u79fb\u3057\u30019 mm\u30b7\u30e7\u30fc\u30c8\u30b9\u30af\u30ea\u30e5\u30fc\u30ad\u30e3\u30c3\u30d7\uff08cat.# 24497\uff09\u3067\u5bc6\u5c01\u5f8c\u3001LC-MS\/MS\u3067\u5206\u6790\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">2. \u4fdd\u6301\u578b\u6db2\u6db2\u62bd\u51fa\uff08SLE\uff09<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u25e6\u3000\u5b9f\u969b\u306e\u6fc3\u5ea6\u306b\u8fd1\u3044\u6fc3\u5ea6\u3067\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3046\u305f\u3081\u306b\u6821\u6b63\u7528\u6a19\u6e96\u8a66\u6599\u304a\u3088\u3073QC\u7528\u6a19\u6e96\u8a66\u6599\u3001\u54041 mL\u306bQuantisal\u7de9\u885d\u6db2\uff08Immunalysis\u793e\u88fd\uff093 mL\u3092\u6dfb\u52a0<br>\u25e6\u3000\u3053\u306e\u7de9\u885d\u6db2\u6dfb\u52a0\u6e08\u307f\u306e\u6a19\u6e96\u8a66\u6599\u305d\u308c\u305e\u308c100 \u00b5L\u30922 mL\u5bb9\u91cf\u306e\u5fae\u91cf\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6\u306b\u5165\u308c\u305f\u5f8c\u30015%\u6c34\u9178\u5316\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0100 \u00b5L\u3068\u5185\u90e8\u6a19\u6e96\u7269\u8cea20 \u00b5L\u3092\u6dfb\u52a0\u3057\u3001\u64b9\u62cc\uff08\u4ee5\u964d\u3053\u306e\u72b6\u614b\u3092\u30b5\u30f3\u30d7\u30eb\u3068\u3059\u308b\uff09<br>\u25e6\u3000\u5404\u30b5\u30f3\u30d7\u30eb200 \u00b5L\u3092200 mg\u5bb9\u91cf\u306eResprep SLE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8(cat.# 28302)\u306b\u5145\u586b\uff08\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306a\u5206\u6790\u306b\u306f\u3001Resprep SLE96\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\uff08cat.# 28304\uff09\u304c\u4f7f\u7528\u53ef\u80fd\uff09<br>\u25e6\u3000\u5145\u586b\u5264\u306b\u5404\u30b5\u30f3\u30d7\u30eb\u304c\u4fdd\u6301\u3055\u308c\u308b\u3088\u3046\u306b\u3001\u6700\u521d\u306e\u6570\u79d2\u9593\u306f\u8efd\u3044\u771f\u7a7a\u72b6\u614b\u306b\u3057\u3001\u305d\u306e\u5f8c\u306e5\u5206\u9593\u3001\u5404\u30b5\u30f3\u30d7\u30eb\u3092\u5145\u586b\u5264\u306b\u4fdd\u6301\u3055\u305b\u305f\u5f8c\u3001\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3:\u30a4\u30bd\u30d7\u30ed\u30d1\u30ce\u30fc\u30eb\u309295:5\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db2500 \u00b5L\u306b\u305d\u308c\u305e\u308c\u6eb6\u89e3\u3055\u305b\u308b<br>\u25e6\u3000\u5404\u30b5\u30f3\u30d7\u30eb\u3092\u84b8\u767a\u4e7e\u56fa\u3057\u305f\u5f8c\u30010.1%\u30ae\u9178\u6c34\u6eb6\u6db2:0.1%\u30ae\u9178\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u6db2\u309290:10\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db2100 \u00b5L\u306b\u518d\u6eb6\u89e3\u3055\u305b\u3001\u64b9\u62cc<br>\u25e6\u3000\u30a4\u30f3\u30b5\u30fc\u30c8\u4ed8\u304d\u306eLC\u30d0\u30a4\u30a2\u30eb\uff082.0 mL\u8910\u8272\u30b7\u30e7\u30fc\u30c8\u30ad\u30e3\u30c3\u30d7\u30d0\u30a4\u30a2\u30eb\uff1acat.# 21142\u300150 \u00b5L\u30a4\u30f3\u30b5\u30fc\u30c8\uff1acat.# 24513\uff09\u306b\u8a66\u6599\u3092\u79fb\u3057\u30019 mm\u30b7\u30e7\u30fc\u30c8\u30b9\u30af\u30ea\u30e5\u30fc\u30ad\u30e3\u30c3\u30d7\uff08cat.# 24497\uff09\u3067\u5bc6\u5c01\u5f8c\u3001LC-MS\/MS\u3067\u5206\u6790\u3057\u305f\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">3. \u5869\u6790\u652f\u63f4\u6db2\u6db2\u62bd\u51fa\uff08SALLE\uff09<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u25e6\u3000\u5b9f\u969b\u306e\u6fc3\u5ea6\u306b\u8fd1\u3044\u6fc3\u5ea6\u3067\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3046\u305f\u3081\u306b\u6821\u6b63\u7528\u6a19\u6e96\u8a66\u6599\u304a\u3088\u3073QC\u7528\u6a19\u6e96\u8a66\u6599\u3001\u54041 mL\u306bQuantisal\u7de9\u885d\u6db2\uff08Immunalysis\u793e\u88fd\uff093 mL\u3092\u6dfb\u52a0<br>\u25e6\u3000\u3053\u306e\u7de9\u885d\u6db2\u6dfb\u52a0\u6e08\u307f\u306e\u6a19\u6e96\u8a66\u6599\u305d\u308c\u305e\u308c100 \u00b5L\u30922 mL\u5bb9\u91cf\u306e\u5fae\u91cf\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6\u306b\u5165\u308c\u305f\u5f8c\u3001\u5185\u90e8\u6a19\u6e96\u7269\u8cea20 \u00b5L\u3092\u6dfb\u52a0\u3057\u300110\u79d2\u9593\u64b9\u62cc\uff08\u4ee5\u964d\u3053\u306e\u72b6\u614b\u3092\u30b5\u30f3\u30d7\u30eb\u3068\u3059\u308b\uff09<br>\u25e6\u3000\u5404\u30b5\u30f3\u30d7\u30eb\u304c\u5165\u3063\u3066\u3044\u308b\u30c1\u30e5\u30fc\u30d6\u306b\u3001\u98fd\u548cNaCl\u6eb6\u6db2100 \u00b5L\u3092\u5165\u308c\u305f\u5f8c\u3001\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb280 \u00b5L\u3092\u6dfb\u52a0\u3057\u3001\u518d\u5ea610\u79d2\u9593\u64b9\u62cc\u5f8c\u30013700 rpm\u306710\u5206\u9593\u9060\u5fc3\u5206\u96e2\u3092\u5b9f\u65bd<br>\u25e6\u3000\u6709\u6a5f\u5c64200 \u00b5L\u3092\u8a66\u9a13\u7ba1\u306b\u6c34\u6eb6\u6db2\u3068\u3057\u3066\u63a1\u53d6\u3057\u3001\u7a92\u7d20\u4e0b\u3067\u84b8\u767a\u4e7e\u56fa<br>\u25e6\u3000\u5404\u30b5\u30f3\u30d7\u30eb\u306b\u30010.1%\u30ae\u9178\u6c34\u6eb6\u6db2:0.1%\u30ae\u9178\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u6db2\u309290:10\u3067\u8abf\u88fd\u3057\u305f\u6eb6\u6db250 \u00b5L\u3092\u6dfb\u52a0\u3057\u3001\u518d\u5ea6\u64b9\u62cc<br>\u25e6\u3000\u30a4\u30f3\u30b5\u30fc\u30c8\u4ed8\u304d\u306eLC\u30d0\u30a4\u30a2\u30eb\uff082.0 mL\u8910\u8272\u30b7\u30e7\u30fc\u30c8\u30ad\u30e3\u30c3\u30d7\u30d0\u30a4\u30a2\u30eb\uff1acat.# 21142\u300150 \u00b5L\u30a4\u30f3\u30b5\u30fc\u30c8\uff1acat.# 24513\uff09\u306b\u8a66\u6599\u3092\u79fb\u3057\u30019 mm\u30b7\u30e7\u30fc\u30c8\u30b9\u30af\u30ea\u30e5\u30fc\u30ad\u30e3\u30c3\u30d7\uff08cat.# 24497\uff09\u3067\u5bc6\u5c01\u5f8c\u3001LC-MS\/MS\u3067\u5206\u6790\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u30ad\u30c3\u30c8\u304b\u3089\u306e\u56de\u53ce\u91cf\u691c\u8a3c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9f\u969b\u306bQuantisal\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u305f\u969b\u306e\u3001\u30b5\u30f3\u30d7\u30eb\u56de\u53ce\u91cf\u3092\u78ba\u8a8d\u3059\u308b\u30c6\u30b9\u30c8\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u307e\u305a\u3001\u30ad\u30c3\u30c8\u5185\u306e\u30b9\u30dd\u30f3\u30b8\u3092\u3001\u5408\u6210\u53e3\u8154\u6db2\u306e\u30d6\u30e9\u30f3\u30af\u30b5\u30f3\u30d7\u30eb1 mL\uff08150 ng\/mL\u306e\u6fc3\u5ea6\u306b\u306a\u308b\u3088\u3046\u306b\u6dfb\u52a0\u6e08\u307f\uff09\u306b\u6d78\u3057\u307e\u3057\u305f\u3002\u6b21\u306b\u3001\u3053\u306e1 mL\u3092\u3059\u3079\u3066\u5438\u53ce\u3057\u305f\u30b9\u30dd\u30f3\u30b8\u3092\u7de9\u885d\u6db2\u306b\u6d78\u3057\u3001\u51b7\u8535\u5eab\u3067\u4e00\u6669\u4fdd\u7ba1\u3057\u3001\u305d\u306e\u5f8c\u3001SALLE\u3068\u540c\u69d8\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3067\u51e6\u7406\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u3088\u3046\u306b\u3057\u3066\u3001\u30b9\u30dd\u30f3\u30b8\u304b\u3089\u306e\u30b5\u30f3\u30d7\u30eb\u56de\u53ce\u65b9\u6cd5\uff08\u624b\u52d5\u5727\u643e vs. \u9060\u5fc3\u5206\u96e2\uff09\u306b\u3088\u308b\u56de\u53ce\u91cf\u3084\u5206\u6790\u6210\u5206\u306e\u56de\u53ce\u7387\u3078\u306e\u5f71\u97ff\u3082\u691c\u8a3c\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u6790\u6761\u4ef6<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u53e3\u8154\u6db2\u30b5\u30f3\u30d7\u30eb\u3092\u7528\u3044\u305f\u4e71\u7528\u85ac\u7269\u5206\u6790\u3092\u4ee5\u4e0b\u306e\u6761\u4ef6\u3067\u884c\u3044\u307e\u3057\u305f\u3002\u5404\u5316\u5408\u7269\u306e\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3055\u308c\u305f\u30a4\u30aa\u30f3\u306f<strong>Table II<\/strong>\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u88c5\u7f6e : \u3000\u5cf6\u6d25 Nexera X2 LC\u3000\uff08\u691c\u51fa\u5668\uff1aSCIEX 4500 MS\/MS\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u30ab\u30e9\u30e0 : \u00a0 \u00a0Raptor Biphenyl 2.7 \u00b5m, 50 mm x 2.1 mm (cat.# 9309A52)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0: \u00a0 \u00a0Raptor Biphenyl EXP \u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8 5 x 2.1 mm, 2.7 \u00b5m (cat # 9309A0252)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u79fb\u52d5\u76f8A: &nbsp; &nbsp;0.1% \u30ae\u9178\u6c34\u6eb6\u6db2<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u79fb\u52d5\u76f8B: &nbsp; &nbsp;0.1% \u30ae\u9178\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u6db2<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\uff1a15% B (0\u5206) \u2192 20% B (1.00\u5206) &nbsp;\u2192 20% B (2.00\u5206) \u2192 50% B (4.00\u5206)\u2192 60% B (6.00\u5206)\u2192 100% B (8.00\u5206) \u2192 100% B (9.00\u5206) &nbsp;\u2192 &nbsp;15% B (9.01\u5206) &nbsp;\u2192 &nbsp;15% B (10.00\u5206)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6d41\u901f: &nbsp; &nbsp;0.5 mL\/min<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\u5165\u91cf: &nbsp; &nbsp;5 \u00b5L<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u6e29\u5ea6: &nbsp; &nbsp;40 \u00b0C<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a4\u30aa\u30f3\u5316\u30e2\u30fc\u30c9: &nbsp; &nbsp;Positive ESI<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> \u30bf\u30fc\u30b2\u30c3\u30c8\u4e71\u7528\u85ac\u7269\u3068LC-MS\/MS\u5206\u6790\u3067\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3055\u308c\u305f\u5404\u30a4\u30aa\u30f3<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u30bf\u30fc\u30b2\u30c3\u30c8\u6210\u5206<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>tR<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Precursor Ion<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Product Ion 1<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>Product Ion 2<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Morphine<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.82<\/td><td class=\"has-text-align-center\" data-align=\"center\">286.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">152.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">165.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Pregabalin<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.88<\/td><td class=\"has-text-align-center\" data-align=\"center\">160.18<\/td><td class=\"has-text-align-center\" data-align=\"center\">55<\/td><td class=\"has-text-align-center\" data-align=\"center\">97.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Oxymorphone<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.92<\/td><td class=\"has-text-align-center\" data-align=\"center\">302.14<\/td><td class=\"has-text-align-center\" data-align=\"center\">227.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">198.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Cathinone<\/td><td class=\"has-text-align-center\" data-align=\"center\">0.94<\/td><td class=\"has-text-align-center\" data-align=\"center\">149.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">132.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">106.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Amphetamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.18<\/td><td class=\"has-text-align-center\" data-align=\"center\">136.22<\/td><td class=\"has-text-align-center\" data-align=\"center\">91.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">65.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hydromorphone<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.22<\/td><td class=\"has-text-align-center\" data-align=\"center\">286.16<\/td><td class=\"has-text-align-center\" data-align=\"center\">184.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">156.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Gabapentin<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.22<\/td><td class=\"has-text-align-center\" data-align=\"center\">172.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">154.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">137.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Methcathinone<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.33<\/td><td class=\"has-text-align-center\" data-align=\"center\">164.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">146.15<\/td><td class=\"has-text-align-center\" data-align=\"center\">131.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">MDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">180.13<\/td><td class=\"has-text-align-center\" data-align=\"center\">163.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">105.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Methamphetamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.53<\/td><td class=\"has-text-align-center\" data-align=\"center\">150.25<\/td><td class=\"has-text-align-center\" data-align=\"center\">91.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">119.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Phentermine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">150.24<\/td><td class=\"has-text-align-center\" data-align=\"center\">91.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">133.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Methylone<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.80<\/td><td class=\"has-text-align-center\" data-align=\"center\">207.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">159.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">189.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Lidocaine<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.83<\/td><td class=\"has-text-align-center\" data-align=\"center\">235.40<\/td><td class=\"has-text-align-center\" data-align=\"center\">86.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">58.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Naloxone<\/td><td class=\"has-text-align-center\" data-align=\"center\">1.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">328.27<\/td><td class=\"has-text-align-center\" data-align=\"center\">310.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">212.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Dihydrocodeine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.09<\/td><td class=\"has-text-align-center\" data-align=\"center\">302.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">199.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">128.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">MDMA<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.15<\/td><td class=\"has-text-align-center\" data-align=\"center\">194.17<\/td><td class=\"has-text-align-center\" data-align=\"center\">163.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">105.1<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Codeine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.22<\/td><td class=\"has-text-align-center\" data-align=\"center\">300.16<\/td><td class=\"has-text-align-center\" data-align=\"center\">152.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">165.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">6-Acetylmorphine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.38<\/td><td class=\"has-text-align-center\" data-align=\"center\">328.30<\/td><td class=\"has-text-align-center\" data-align=\"center\">164.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">211.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Levamisole<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.59<\/td><td class=\"has-text-align-center\" data-align=\"center\">205.08<\/td><td class=\"has-text-align-center\" data-align=\"center\">178.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">91.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Oxycodone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.69<\/td><td class=\"has-text-align-center\" data-align=\"center\">316.19<\/td><td class=\"has-text-align-center\" data-align=\"center\">298.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">169.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Naltrexone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.85<\/td><td class=\"has-text-align-center\" data-align=\"center\">342.19<\/td><td class=\"has-text-align-center\" data-align=\"center\">324.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">267.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">MDEA<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.92<\/td><td class=\"has-text-align-center\" data-align=\"center\">208.13<\/td><td class=\"has-text-align-center\" data-align=\"center\">163.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">105.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hydrocodone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2.98<\/td><td class=\"has-text-align-center\" data-align=\"center\">300.14<\/td><td class=\"has-text-align-center\" data-align=\"center\">199.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">128.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Norketamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.30<\/td><td class=\"has-text-align-center\" data-align=\"center\">224.08<\/td><td class=\"has-text-align-center\" data-align=\"center\">125.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">89.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Eutylone<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.39<\/td><td class=\"has-text-align-center\" data-align=\"center\">236.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">188.05<\/td><td class=\"has-text-align-center\" data-align=\"center\">218.15<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Norfentanyl<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.55<\/td><td class=\"has-text-align-center\" data-align=\"center\">233.13<\/td><td class=\"has-text-align-center\" data-align=\"center\">84.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">55.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4-Hydroxy nitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.70<\/td><td class=\"has-text-align-center\" data-align=\"center\">369.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">100.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">72.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Pentylone<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.73<\/td><td class=\"has-text-align-center\" data-align=\"center\">236.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">188.05<\/td><td class=\"has-text-align-center\" data-align=\"center\">218.15<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Dextrorphan<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">258.15<\/td><td class=\"has-text-align-center\" data-align=\"center\">157.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">201.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Xylazine<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.85<\/td><td class=\"has-text-align-center\" data-align=\"center\">221.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">90.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">71.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Ketamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">3.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">238.07<\/td><td class=\"has-text-align-center\" data-align=\"center\">125.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">89.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benzoylecgonine<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">290.13<\/td><td class=\"has-text-align-center\" data-align=\"center\">168.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">77.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Meperidine<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.03<\/td><td class=\"has-text-align-center\" data-align=\"center\">248.14<\/td><td class=\"has-text-align-center\" data-align=\"center\">220.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">174.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">7-Aminoclonazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.05<\/td><td class=\"has-text-align-center\" data-align=\"center\">286.08<\/td><td class=\"has-text-align-center\" data-align=\"center\">121.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">250.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Cocaine<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.28<\/td><td class=\"has-text-align-center\" data-align=\"center\">304.18<\/td><td class=\"has-text-align-center\" data-align=\"center\">182.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">77.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">7-Hydroxymitragynine<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">415.60<\/td><td class=\"has-text-align-center\" data-align=\"center\">189.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">175.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Cocaethylene<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.60<\/td><td class=\"has-text-align-center\" data-align=\"center\">318.21<\/td><td class=\"has-text-align-center\" data-align=\"center\">196.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">82.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">LSD<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.60<\/td><td class=\"has-text-align-center\" data-align=\"center\">324.27<\/td><td class=\"has-text-align-center\" data-align=\"center\">223.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">208.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Norbuprenorphine<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.65<\/td><td class=\"has-text-align-center\" data-align=\"center\">414.30<\/td><td class=\"has-text-align-center\" data-align=\"center\">250.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">187.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Chlordiazepoxide<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.74<\/td><td class=\"has-text-align-center\" data-align=\"center\">300.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">282.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">227.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Acetyl fentanyl<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.75<\/td><td class=\"has-text-align-center\" data-align=\"center\">323.28<\/td><td class=\"has-text-align-center\" data-align=\"center\">188.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">105.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Zolpidem<\/td><td class=\"has-text-align-center\" data-align=\"center\">4.80<\/td><td class=\"has-text-align-center\" data-align=\"center\">308.21<\/td><td class=\"has-text-align-center\" data-align=\"center\">235.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">218.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Fentanyl<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.15<\/td><td class=\"has-text-align-center\" data-align=\"center\">337.29<\/td><td class=\"has-text-align-center\" data-align=\"center\">188.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">105.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Dextromethorphan<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.17<\/td><td class=\"has-text-align-center\" data-align=\"center\">272.19<\/td><td class=\"has-text-align-center\" data-align=\"center\">215.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">170.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Isotonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.18<\/td><td class=\"has-text-align-center\" data-align=\"center\">411.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">100.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">72.15<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">PCP<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">244.15<\/td><td class=\"has-text-align-center\" data-align=\"center\">86.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">159.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Buprenorphine<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">468.30<\/td><td class=\"has-text-align-center\" data-align=\"center\">396.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">414.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Midazolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.22<\/td><td class=\"has-text-align-center\" data-align=\"center\">326.19<\/td><td class=\"has-text-align-center\" data-align=\"center\">291.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">248.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Propoxyphene<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.33<\/td><td class=\"has-text-align-center\" data-align=\"center\">340.27<\/td><td class=\"has-text-align-center\" data-align=\"center\">265.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">58.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Tianeptine<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.38<\/td><td class=\"has-text-align-center\" data-align=\"center\">437.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">293.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">229.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Protonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.49<\/td><td class=\"has-text-align-center\" data-align=\"center\">411.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">100.30<\/td><td class=\"has-text-align-center\" data-align=\"center\">72.15<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Sufentanil<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.62<\/td><td class=\"has-text-align-center\" data-align=\"center\">387.23<\/td><td class=\"has-text-align-center\" data-align=\"center\">111.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">234.30<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">EDDP<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.62<\/td><td class=\"has-text-align-center\" data-align=\"center\">278.15<\/td><td class=\"has-text-align-center\" data-align=\"center\">234.30<\/td><td class=\"has-text-align-center\" data-align=\"center\">249.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Mitragynine<\/td><td class=\"has-text-align-center\" data-align=\"center\">5.78<\/td><td class=\"has-text-align-center\" data-align=\"center\">399.25<\/td><td class=\"has-text-align-center\" data-align=\"center\">159.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">153.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">iso-Butonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">425.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">100.30<\/td><td class=\"has-text-align-center\" data-align=\"center\">72.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Methadone<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.25<\/td><td class=\"has-text-align-center\" data-align=\"center\">310.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">264.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">105.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Lorazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.35<\/td><td class=\"has-text-align-center\" data-align=\"center\">321.05<\/td><td class=\"has-text-align-center\" data-align=\"center\">275.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">229.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Oxazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.40<\/td><td class=\"has-text-align-center\" data-align=\"center\">287.07<\/td><td class=\"has-text-align-center\" data-align=\"center\">268.80<\/td><td class=\"has-text-align-center\" data-align=\"center\">241.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Clonazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">316.09<\/td><td class=\"has-text-align-center\" data-align=\"center\">270.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">214.10<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Nordiazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.80<\/td><td class=\"has-text-align-center\" data-align=\"center\">271.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">139.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">164.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Clonazolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">6.83<\/td><td class=\"has-text-align-center\" data-align=\"center\">354.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">308.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">279.80<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Alprazolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.28<\/td><td class=\"has-text-align-center\" data-align=\"center\">309.11<\/td><td class=\"has-text-align-center\" data-align=\"center\">280.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">204.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Temazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.30<\/td><td class=\"has-text-align-center\" data-align=\"center\">301.11<\/td><td class=\"has-text-align-center\" data-align=\"center\">255.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">282.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Bromazolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.40<\/td><td class=\"has-text-align-center\" data-align=\"center\">353.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">325.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">218.00<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Etizolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.52<\/td><td class=\"has-text-align-center\" data-align=\"center\">343.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">314.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">258.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Diazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.59<\/td><td class=\"has-text-align-center\" data-align=\"center\">285.07<\/td><td class=\"has-text-align-center\" data-align=\"center\">153.90<\/td><td class=\"has-text-align-center\" data-align=\"center\">192.90<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Cannabidiol<\/td><td class=\"has-text-align-center\" data-align=\"center\">7.85<\/td><td class=\"has-text-align-center\" data-align=\"center\">315.20<\/td><td class=\"has-text-align-center\" data-align=\"center\">193.00<\/td><td class=\"has-text-align-center\" data-align=\"center\">123.20<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Delta-9-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">8.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">315.50<\/td><td class=\"has-text-align-center\" data-align=\"center\">193.10<\/td><td class=\"has-text-align-center\" data-align=\"center\">259.10<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u679c\u3068\u8003\u5bdf<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">SLE\u306b\u304a\u3051\u308b\u6700\u9069\u306a\u6eb6\u51fa\u6eb6\u5a92\u306e\u9078\u5b9a<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306bSLE\u3092\u63a1\u7528\u3059\u308b\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001\u5206\u6790\u6210\u5206\u306e\u6975\u6027\u306f\u591a\u5c90\u306b\u308f\u305f\u308a\u3001\u305d\u306e\u91cf\u3082\u591a\u304f\u306a\u308a\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u9069\u5207\u306b\u5206\u6790\u6210\u5206\u3092\u6eb6\u51fa\u3055\u305b\u308b\u6eb6\u51fa\u6eb6\u5a92\u306e\u9078\u5b9a\u304c\u91cd\u8981\u306b\u306a\u3063\u3066\u304d\u307e\u3059\u3002\u305d\u3053\u3067\u3001\u6700\u9069\u306a\u6eb6\u51fa\u6eb6\u5a92\u3092\u9078\u5b9a\u3059\u308b\u305f\u3081\u306b\u30017\u7a2e\u985e\u306e\u6eb6\u51fa\u6eb6\u5a92\u3092\u6bd4\u8f03\u3059\u308b\u30c6\u30b9\u30c8\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u30c6\u30b9\u30c8\u3057\u305f\u6eb6\u5a92\u306f\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3001\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3\u3001\u30d8\u30ad\u30b5\u30f3\u300150:50 \u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3:\u9162\u9178\u30a8\u30c1\u30eb\u300195:5 \u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3:\u30a4\u30bd\u30d7\u30ed\u30d1\u30ce\u30fc\u30eb\u300195:5 \u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3:\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u3059\u3002\u4f4e\u6fc3\u5ea6\u3068\u9ad8\u6fc3\u5ea6\u306e\u30b5\u30f3\u30d7\u30eb\u3067\u30c6\u30b9\u30c8\u3055\u308c\u3001\u3059\u3079\u3066\u306e\u5206\u6790\u6210\u5206\u306b\u3064\u3044\u3066\u30d4\u30fc\u30af\u5f62\u72b6\u3001\u30d4\u30fc\u30af\u9762\u7a4d\u3001\u30d4\u30fc\u30af\u9ad8\u3055\u3092\u6bd4\u8f03\u3057\u305f\u7d50\u679c\u300195:5 \u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3:\u30a4\u30bd\u30d7\u30ed\u30d1\u30ce\u30fc\u30eb\u304c\u6700\u3082\u591a\u304f\u306e\u5206\u6790\u6210\u5206\u3067\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u611f\u5ea6\u3092\u793a\u3057\u305f\u305f\u3081\u3001\u6700\u9069\u306a\u6eb6\u5a92\u3068\u3057\u3066\u9078\u5b9a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u306e\u6bd4\u8f03<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306bSLE\u304a\u3088\u3073SALLE\u3092\u63a1\u7528\u3057\u305f\u7d50\u679c\u3001\u5e0c\u91c8\u6ce8\u5165\u6cd5\u3068\u6bd4\u8f03\u3057\u3066\u3001\u307b\u3068\u3093\u3069\u306e\u5206\u6790\u6210\u5206\u3067\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u5927\u5e45\u306b\u5411\u4e0a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SLE\u306f\u3001\u7279\u6027\u304c\u985e\u4f3c\u3059\u308b\u5206\u6790\u6210\u5206\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u7de9\u885d\u6db2\u3092\u9664\u53bb\u3059\u308b\u306e\u306b\u6709\u52b9\u3067\u3057\u305f\u3002\u4e00\u65b9\u3001SALLE\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u7279\u6027\u3092\u6301\u3064\u85ac\u7269\u306b\u542b\u307e\u308c\u308b\u5316\u5408\u7269\u5168\u822c\u306b\u5bfe\u3057\u3066\u826f\u597d\u306a\u7d50\u679c\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u672c\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306b\u304a\u3051\u308bSLE\u306b\u3088\u308b\u524d\u51e6\u7406\u3067\u306f\u3001\u591a\u304f\u306e\u30aa\u30d4\u30a8\u30fc\u30c8\u3067\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u5411\u4e0a\u3057\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u30d7\u30ec\u30ac\u30d0\u30ea\u30f3\u3001\u30ac\u30d0\u30da\u30f3\u30c1\u30f3\u3001THC\u3001CBD\u306b\u3064\u3044\u3066\u306f\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u6975\u3081\u3066\u4f4e\u304f\u3001\u8a31\u5bb9\u3067\u304d\u308b\u6c34\u6e96\u306b\u306f\u9054\u3057\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u3053\u308c\u3089\u306e\u6210\u5206\u306b\u3064\u3044\u3066\u306fSLE\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3067\u306e\u7cbe\u5ea6\u304a\u3088\u3073\u518d\u73fe\u6027\u306e\u8a55\u4fa1\u3092\u884c\u3063\u3066\u3044\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 1<\/strong>\u306b\u306f\u3001SLE\u3001SALLE\u3001\u5e0c\u91c8\u6ce8\u5165\u6cd5\u3068\u3044\u30463\u7a2e\u985e\u306e\u524d\u51e6\u7406\u3092\u884c\u3063\u305f\u5404\u30b5\u30f3\u30d7\u30eb\uff08\u6fc3\u5ea610 ng\/mL\uff09\u306e\u30d4\u30fc\u30af\u9762\u7a4d\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> SLE\u3001SALLE\u3001\u5e0c\u91c8\u6ce8\u5165\u6cd5\u3092\u884c\u3063\u305f\u6fc3\u5ea610 ng\/mL\u30b5\u30f3\u30d7\u30eb\u306e\u30d4\u30fc\u30af\u9762\u7a4d\u30ec\u30b9\u30dd\u30f3\u30b9\u6bd4\u8f03<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"587\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-CFAN4466-01-1024x587.jpg\" alt=\"\" class=\"wp-image-19143\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-01-1024x587.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-01-300x172.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-01-768x440.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-01.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u30a8\u30e9\u30fc\u30d0\u30fc\u306f\u6a19\u6e96\u504f\u5dee\u3092\u8868\u3057\u307e\u3059\u3002<\/em><\/p>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">SALLE\u3084SLE\u304c\u5e0c\u91c8\u6ce8\u5165\u6cd5\u3088\u308a\u3082\u512a\u308c\u305f\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u793a\u3059\u306e\u306f\u3001\u30df\u30c8\u30e9\u30ae\u30cb\u30f3\u3068\u30ce\u30eb\u30d5\u30a7\u30f3\u30bf\u30cb\u30eb\u306e\u30d4\u30fc\u30af\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u6bd4\u8f03\u3057\u305f\u4ee5\u4e0b\u306e\u7d50\u679c\u304b\u3089\u3082\u5206\u304b\u308a\u307e\u3059\u3002\u30df\u30c8\u30e9\u30ae\u30cb\u30f3\u306fSALLE\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306b\u6700\u3082\u9ad8\u3044\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u793a\u3057 (<strong>Figure 2<\/strong>)\u3001\u30ce\u30eb\u30d5\u30a7\u30f3\u30bf\u30cb\u30eb\u306fSLE\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306b\u9ad8\u3044\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u793a\u3057\u307e\u3057\u305f (<strong>Figure 3<\/strong>)\u3002\u3053\u306e\u4f8b\u304c\u660e\u793a\u3057\u3066\u3044\u308b\u306e\u306f\u3001\u5206\u6790\u6210\u5206\u306b\u3088\u3063\u3066\u6700\u3082\u52b9\u679c\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306f\u7570\u306a\u308b\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u3069\u306e\u524d\u51e6\u7406\u6cd5\u3092\u9078\u629e\u3059\u308b\u304b\u6c7a\u5b9a\u3059\u308b\u969b\u306b\u306f\u3001\u5206\u6790\u6210\u5206\u30ea\u30b9\u30c8\u3068LOQ\u306e\u8981\u4ef6\u3092\u614e\u91cd\u306b\u8003\u616e\u3059\u3079\u304d\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> \u30df\u30c8\u30e9\u30ae\u30cb\u30f3\u306b\u95a2\u3059\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u5225\u30ec\u30b9\u30dd\u30f3\u30b9\u6bd4\u8f03\u3000<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0842.png\" alt=\"Comparison of Sample Preparation Techniques on Mitragynine in Oral Fluid\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0842<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Mitragynine\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/4098-40-2\/Mitragynine\" target=\"_blank\" rel=\"noopener\">Mitragynine<\/a><\/td><td class=\"oth\">5.78<\/td><td class=\"oth\">100<\/td><td class=\"oth\">399.25<\/td><td class=\"oth\">159.00<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A0252<\/li><li>9309A52<\/li><li>24513<\/li><li>21142<\/li><li>24497<\/li><li>28302<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Fluids<\/li><li>Mitragynine<\/li><li>Oral<\/li><li>SALLE<\/li><li>SLE<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0842.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> \u30ce\u30eb\u30d5\u30a7\u30f3\u30bf\u30cb\u30eb\u306b\u95a2\u3059\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u5225\u30ec\u30b9\u30dd\u30f3\u30b9\u6bd4\u8f03<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0841.png\" alt=\"Comparison of Sample Preparation Techniques on Norfentanyl in Oral Fluid\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0841<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">t<sub>R<\/sub> (min)<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor Ion<\/th><th style=\"text-align: center;width: 75px\">Product Ion<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for Norfentanyl\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1609-66-1\/Norfentanyl\" target=\"_blank\" rel=\"noopener\">Norfentanyl<\/a><\/td><td class=\"oth\">3.55<\/td><td class=\"oth\">100<\/td><td class=\"oth\">233.13<\/td><td class=\"oth\">84.10<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A0252<\/li><li>9309A52<\/li><li>24513<\/li><li>21142<\/li><li>24497<\/li><li>28302<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Fluids<\/li><li>Norfentanyl<\/li><li>Oral<\/li><li>SALLE<\/li><li>SLE<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0841.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<h3 class=\"wp-block-heading\">\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u30ad\u30c3\u30c8\u304b\u3089\u306e\u56de\u53ce\u91cf\u691c\u8a3c<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u53e3\u8154\u6db2\u63a1\u53d6\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3068\u7de9\u885d\u6db2\u3092\u63a1\u53d6\u88c5\u7f6e\u5185\u306e\u30b9\u30dd\u30f3\u30b8\u304b\u3089\u9664\u53bb\u3059\u308b\u3053\u3068\u304c\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002\u30b9\u30dd\u30f3\u30b8\u304b\u3089\u30b5\u30f3\u30d7\u30eb\u3092\u56de\u53ce\u3059\u308b\u4e3b\u306a\u65b9\u6cd5\u306f\u3001\u624b\u52d5\u5727\u643e\u3068\u9060\u5fc3\u5206\u96e2\u306e2\u3064\u3067\u3059\u3002<strong>Figure 4<\/strong>\u304b\u3089\u5206\u304b\u308b\u3088\u3046\u306b\u3001\u9060\u5fc3\u5206\u96e2\u3067\u306f4 mL\u5168\u91cf\u304c\u307b\u307c\u56de\u53ce\u3055\u308c\u305f\u306e\u306b\u5bfe\u3057\u3001\u624b\u52d5\u5727\u643e\u3067\u306f\u7d043 mL\u304c\u56de\u53ce\u3055\u308c\u305f\u306e\u307f\u3067\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> \u53e3\u8154\u6db2\u30b5\u30f3\u30d7\u30eb\u3092\u63a1\u53d6\u88c5\u7f6e\u304b\u3089\u3088\u308a\u591a\u304f\u56de\u53ce\u3067\u304d\u305f\u306e\u306f\u9060\u5fc3\u5206\u96e2\uff08\u5de6\uff09\u3067\u3057\u305f\u3002\uff08\u53f3\uff09\u306f\u624b\u52d5\u5727\u643e\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"481\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-CFAN4466-04-1024x481.jpg\" alt=\"\" class=\"wp-image-19149\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-04-1024x481.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-04-300x141.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-04-768x361.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-04.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30dd\u30f3\u30b8\u304b\u3089\u3059\u3079\u3066\u306e\u53e3\u8154\u6db2\u3068\u7de9\u885d\u6db2\u3092\u62bd\u51fa\u3059\u308b\u306b\u306f\u3001\u9060\u5fc3\u5206\u96e2\u304c\u3088\u308a\u52b9\u679c\u7684\u3067\u3042\u308b\u3053\u3068\u306f\u660e\u3089\u304b\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u7de9\u885d\u6db2\u306b\u6d78\u3055\u308c\u305f\u30b9\u30dd\u30f3\u30b8\u306f\u3082\u308d\u304f\u306a\u3063\u3066\u304a\u308a\u3001\u9ad8\u901f\u3067\u9060\u5fc3\u5206\u96e2\u3059\u308b\u3068\u30a2\u30d7\u30ea\u30b1\u30fc\u30bf\u30fc\u304b\u3089\u7c21\u5358\u306b\u5916\u308c\u3066\u3057\u307e\u3046\u306e\u3067\u3001\u9060\u5fc3\u5206\u96e2\u6642\u306b\u306f\u30b9\u30dd\u30f3\u30b8\u306e\u53d6\u308a\u6271\u3044\u306b\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u9060\u5fc3\u5206\u96e2\u524d\u306b\u30b9\u30dd\u30f3\u30b8\u3092\u30c1\u30e5\u30fc\u30d6\u306e\u5074\u9762\u306b\u6298\u308a\u305f\u305f\u3080\u3053\u3068\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b5\u30f3\u30d7\u30eb\u56de\u53ce\u91cf\u304c\u3069\u306e\u7a0b\u5ea6\u5206\u6790\u6210\u5206\u306e\u56de\u53ce\u7387\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u304b\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u3001\u4e2d\u7a0b\u5ea6\u306eQC\u6fc3\u5ea6(150 ng\/mL)\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u624b\u52d5\u5727\u643e\u3068\u9060\u5fc3\u5206\u96e2\u3067\u56de\u53ce\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306b\u542b\u307e\u308c\u308b68\u7a2e\u985e\u306e\u5206\u6790\u6210\u5206\u306e\u56de\u53ce\u7387\u306f\u3059\u3079\u3066\u3001\u9060\u5fc3\u5206\u96e2\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306e\u65b9\u304c\u826f\u597d\u3067\u3057\u305f\uff08<strong>Figure 5<\/strong>\u53c2\u7167\uff09\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> \u624b\u52d5\u5727\u643e\u3068\u9060\u5fc3\u5206\u96e2\u306b\u3088\u3063\u3066\u56de\u53ce\u3057\u305f\u6fc3\u5ea610 ng\/mL\u30b5\u30f3\u30d7\u30eb\uff08\u30b9\u30dd\u30f3\u30b8\uff09\u306e\u56de\u53ce\u7387\u6bd4\u8f03<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"587\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/figure-article-CFAN4466-05-1024x587.jpg\" alt=\"\" class=\"wp-image-19155\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-05-1024x587.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-05-300x172.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-05-768x440.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4466-05.jpg 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<h3 class=\"wp-block-heading\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 6<\/strong>\u306b\u793a\u3059\u3088\u3046\u306b\u3001SALLE\u306b\u3088\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3092\u63a1\u7528\u3057\u305f\u672c\u5206\u6790\u6761\u4ef6\u3067\u306f\u3001\u53e3\u8154\u6db2\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u65b0\u898f\u7cbe\u795e\u6d3b\u6027\u7269\u8cea\u3092\u542b\u3080\u516868\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u3092\u300110\u5206\u306e\u30b5\u30a4\u30af\u30eb\u30bf\u30a4\u30e0\u3067\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3057\u305f\u3002\u5206\u6790\u306b\u306f\u3001LC-MS\/MS\u7528Raptor Biphenyl\u30ab\u30e9\u30e0\uff0850 \u00d7 2.1 mm\u30012.7 \u00b5m\uff09\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001\u3059\u3079\u3066\u306e\u540c\u91cd\u4f53\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u304c\u9069\u5207\u306b\u884c\u308f\u308c\u305f\u305f\u3081\u3001\u6b63\u78ba\u306a\u5b9a\u91cf\u304c\u53ef\u80fd\u3067\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong> Raptor Biphenyl LC\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5408\u6210\u7d4c\u53e3\u6db2\u4e2d\u306e68\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u306eLC-MS\/MS\u5206\u6790 (SALLE\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406)\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0830.png\" alt=\"Analysis of Drugs of Abuse in Oral Fluid on Raptor Biphenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0830<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9309A0252<\/li><li>9309A52<\/li><li>24513<\/li><li>21142<\/li><li>24497<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>Abuse<\/li><li>Biphenyl<\/li><li>DoA<\/li><li>Drugs<\/li><li>Fluid<\/li><li>Kratom<\/li><li>Nitazenes<\/li><li>Oral<\/li><li>Raptor<\/li><li>Tianeptine<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0830.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<h3 class=\"wp-block-heading\">\u76f4\u7dda\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u7dda\u5f62\u56de\u5e30\uff081\/x \u91cd\u307f\u4ed8\u3051\uff09\u3092\u7528\u3044\u308b\u3068\u3001\u3059\u3079\u3066\u306e\u5206\u6790\u6210\u5206\u306f\u3001\u3044\u305a\u308c\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u306b\u304a\u3044\u3066\u30820.991\u4ee5\u4e0a\u306e\u8a31\u5bb9\u53ef\u80fd\u306aR\u00b2\u5024\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u30bf\u30fc\u30b2\u30c3\u30c8\u306e\u4e71\u7528\u85ac\u7269\u306e\u5206\u6790\u7bc4\u56f2\u3092<strong>Table III<\/strong>\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong> \u53e3\u8154\u6db2\u306b\u542b\u307e\u308c\u308b\u5206\u6790\u6210\u5206\u306e\u5206\u6790\u7bc4\u56f2<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5206\u6790\u6210\u5206<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u7dda\u5f62\u7bc4\u56f2 (ng\/mL)\u3000<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u5206\u6790\u6210\u5206<\/strong><\/th><th class=\"has-text-align-center\" data-align=\"center\"><strong>\u7dda\u5f62\u7bc4\u56f2 (ng\/mL)\u3000<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">Morphine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Cocaine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Pregabalin<\/td><td class=\"has-text-align-center\" data-align=\"center\">50-10,000<\/td><td class=\"has-text-align-center\" data-align=\"center\">7-hydroxymitragynine<\/td><td class=\"has-text-align-center\" data-align=\"center\">10-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Oxymorphone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">LSD<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Cathinone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Cocaethylene<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Amphetamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Norbuprenorphine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hydromorphone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Chlordiazepoxide<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Gabapentin<\/td><td class=\"has-text-align-center\" data-align=\"center\">50-10,000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Acetyl Fentanyl<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Methcathinone<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Zolpidem<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">MDA<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Fentanyl<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Methamphetamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Dextromethorphan<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Phentermine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Isotonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Methylone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Buprenorphine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Lidocaine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">PCP<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Naloxone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Midazolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Dihydrocodeine<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Propoxyphene<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">MDMA<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Tianeptine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Codeine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Protonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">6-Acetylmorphine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Sufentanil<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Levamisole<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">EDDP<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Oxycodone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Mitragynine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Naltrexone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Iso-Butonitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">MDEA<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Methadone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Hydrocodone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Lorazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Norketamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Oxazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Eutylone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Clonazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Norfentanyl<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Nordiazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">4-Hydroxy nitazene<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Clonazolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Pentylone<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Alprazolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Dextrorphan<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Temazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Xylazine<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Bromazolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Ketamine<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Etizolam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Benzoylecgonine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Diazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">Meperidine<\/td><td class=\"has-text-align-center\" data-align=\"center\">2-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Delta-9-THC<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">7-Aminoclonazepam<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><td class=\"has-text-align-center\" data-align=\"center\">Cannabidiol<\/td><td class=\"has-text-align-center\" data-align=\"center\">5-1000<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\u7cbe\u5ea6\u3068\u518d\u73fe\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u306f\u3001SLE\u304a\u3088\u3073SALLE\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u3092\u4f7f\u7528\u3057\u3066\u8907\u6570\u65e5\u306b\u308f\u305f\u3063\u3066\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u5b9a\u91cf\u9650\u754c\uff08LOQ\uff09\u3001\u5b9a\u91cf\u9650\u754c\uff08\u4f4e\uff09\u3001\u5b9a\u91cf\u9650\u754c\uff08\u4e2d\uff09\u3001\u304a\u3088\u3073\u5b9a\u91cf\u9650\u754c\uff08\u9ad8\uff09\u3067\u306e\u56de\u53ce\u7387\u304c\u671f\u5f85\u5024\u306e\u00b115%\u4ee5\u5185\u306b\u53ce\u307e\u308b\u3053\u3068\u3067\u3001\u4e21\u65b9\u306e\u524d\u51e6\u7406\u6cd5\u306b\u304a\u3044\u3066\u30e1\u30bd\u30c3\u30c9\u306e\u7cbe\u5ea6\u304c\u5b9f\u8a3c\u3055\u308c\u307e\u3057\u305f\u3002\u540c\u65e5\u5185\u304a\u3088\u3073\u5225\u65e5\u9593\u306e\u518d\u73fe\u6027\u3082\u3001%RSD\u304cSLE\u30679.12%\u4ee5\u4e0b\u3001SALLE\u30677.45%\u4ee5\u4e0b\u3068\u3001\u8a31\u5bb9\u7bc4\u56f2\u5185\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u30ab\u30e9\u30e0\u5805\u7262\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u306e\u5805\u7262\u6027\u306f\u3001SLE\u304a\u3088\u3073SALLE\u3092\u4f7f\u7528\u3057\u305f\u524d\u51e6\u7406\u6e08\u307f\u30b5\u30f3\u30d7\u30eb\u3092250\u56de\u4ee5\u4e0a\u9023\u7d9a\u3057\u3066\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6ce8\u5165\u3057\u3066\u30c6\u30b9\u30c8\u3057\u307e\u3057\u305f\u3002Raptor Biphenyl\u30ab\u30e9\u30e0\u306f\u975e\u5e38\u306b\u5b89\u5b9a\u3057\u305f\u7d50\u679c\u3092\u793a\u3057\u300168\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u3059\u3079\u3066\u306b\u304a\u3044\u3066\u3001\u6700\u521d\u3068\u6700\u5f8c\u306e\u6ce8\u5165\u306e\u4fdd\u6301\u6642\u9593\u306e\u5909\u52d5\u306f6.21%\u4ee5\u5185\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u8ad6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306e\u5b9f\u9a13\u3067\u5b9f\u8a3c\u3057\u305fSALLE\u304a\u3088\u3073SLE\u3092\u63a1\u7528\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u306f\u3001\u5f93\u6765\u306eSPE\u306b\u6bd4\u3079\u3066\u5927\u5e45\u306a\u6642\u9593\u77ed\u7e2e\u3068\u4f5c\u696d\u52b9\u7387\u5316\u3092\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002\u307e\u305f\u3001LC-MS\/MS\u306b\u3088\u308b\u9ad8\u611f\u5ea6\u30fb\u9ad8\u7cbe\u5ea6\u306a\u53e3\u8154\u6db2\u4e2d\u306e\u85ac\u7269\u5206\u6790\uff0868\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u304a\u3088\u3073\u65b0\u898f\u7cbe\u795e\u6d3b\u6027\u7269\u8cea\u306e\u5206\u6790\uff09\u3092\u53ef\u80fd\u306b\u3057\u307e\u3057\u305f\u3002SALLE\u306f\u591a\u69d8\u306a\u85ac\u7269\u306b\u3001SLE\u306f\u7279\u5b9a\u306e\u85ac\u7269\u30b0\u30eb\u30fc\u30d7\u306b\u9069\u3057\u3066\u304a\u308a\u3001\u76ee\u7684\u306b\u5fdc\u3058\u3066\u4f7f\u3044\u5206\u3051\u304c\u53ef\u80fd\u3067\u3059\u3002\u3069\u3061\u3089\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u3067\u3082\u3001\u5e0c\u91c8\u6ce8\u5165\u6cd5\u306b\u6bd4\u3079\u3066\u5206\u6790\u6210\u5206\u306e\u56de\u53ce\u7387\u304c\u5411\u4e0a\u3057\u3001\u7de9\u885d\u6db2\u9664\u53bb\u3082\u52b9\u679c\u7684\u306b\u884c\u308f\u308c\u305f\u305f\u3081\u3001\u30ab\u30e9\u30e0\u5bff\u547d\u304c\u9577\u304f\u306a\u308a\u3001\u4e0b\u6d41\u306b\u304a\u3051\u308b\u30e1\u30bd\u30c3\u30c9\u3078\u306e\u5f71\u97ff\u304c\u4f4e\u6e1b\u3067\u304d\u307e\u3057\u305f\u3002SALLE\u3068SLE\u306f\u3001\u3044\u305a\u308c\u3082\u30b7\u30f3\u30d7\u30eb\u306a\u624b\u9806\u3001\u77ed\u6642\u9593\u3067\u5b9f\u884c\u3067\u304d\u308b\u305f\u3081\u3001\u5f93\u6765\u306e\u3001\u6642\u9593\u304c\u304b\u304b\u308a\u8907\u96d1\u306a\u624b\u9806\u306eSPE\u3068\u6bd4\u3079\u3066\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002\u4eca\u5f8c\u3001\u53e3\u8154\u6db2\u4e2d\u306e\u4e71\u7528\u85ac\u7269\u306e\u5206\u6790\u306b\u4f7f\u7528\u3055\u308c\u308b\u3053\u3068\u304c\u5897\u3048\u3066\u3044\u304f\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>E.J. Cone, M.A. Huestis, Marilyn, Interpretation of oral fluid tests for drugs of abuse, \u00a0Ann NY Acad Sci, \u00a0 \u00a01098 (2007) 51-103. <a href=\"https:\/\/doi.org\/10.1196\/annals.1384.037\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1196\/annals.1384.037<\/a><\/li>\n\n\n\n<li>S. Uljon, Chapter One-Advances in fentanyl testing, Advances in Clinical Chemistry, 116 (2023)1-30. <a href=\"https:\/\/doi.org\/10.1016\/bs.acc.2023.05.004\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/bs.acc.2023.05.004<\/a><\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\"><em>\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306f\u7814\u7a76\u7528\u9014\u306e\u307f\u306b\u958b\u767a\u3055\u308c\u3066\u304a\u308a\u3001\u8a3a\u65ad\u306b\u4f7f\u7528\u3059\u308b\u306b\u306f\u3055\u3089\u306a\u308b\u691c\u8a3c\u304c\u5fc5\u8981\u3067\u3059\u3002<\/em><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A52\">                                \u30ab\u30bf\u30ed\u30b0No. 9309A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl, 2.7 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A52\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A0252\">                                \u30ab\u30bf\u30ed\u30b0No. 9309A0252                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Biphenyl EXP Guard Column Cartridge, 2.7 \u00b5m, 5 x 2.1 mm, 3-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9309A0252\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">                                \u30ab\u30bf\u30ed\u30b0No. 25808                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">EXP Direct Connect Holder for EXP Guard Cartridges, Includes Fitting &amp; Ferrules<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25808\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28302\">                                \u30ab\u30bf\u30ed\u30b0No. 28302                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Resprep SLE Cartridges, 200 mg\/3 mL Cartridge, 50-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28302\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28304\">                                \u30ab\u30bf\u30ed\u30b0No. 28304                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Resprep SLE 96-Well Plates, 200 mg\/2 mL Each Well, ea.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28304\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21142\">                                \u30ab\u30bf\u30ed\u30b0No. 21142                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short-Cap Vial with Grad Marking Spot, 9-425 Screw-Thread, 2.0 mL, 9 mm, 12 x 32 (vial only), Amber, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21142\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24513\">                                \u30ab\u30bf\u30ed\u30b0No. 24513                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial Inserts, Glass, Big Mouth w\/ Bottom Spring, 50 \u00b5L, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24513\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24497\">                                \u30ab\u30bf\u30ed\u30b0No. 24497                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short Screw Cap, Polypropylene, Screw-Thread, PTFE\/Silicone\/PTFE Septa, Blue, Preassembled, 2.0 mL, 9 mm, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24497\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u53e3\u8154\u6db2\u4e2d\u306e\u4e71\u7528\u85ac\u7269\u691c\u67fb\u306b\u304a\u3051\u308b\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u306e\u8ab2\u984c\u3092\u89e3\u6c7a\u3057\u307e\u3059\u3002SALLE\u3068SLE\u3092\u5e0c\u91c8\u6ce8\u5165\u6cd5\u3068\u6bd4\u8f03\u3057\u305f\u7d50\u679c\u3001\u5927\u5e45\u306a\u6642\u9593\u77ed\u7e2e\u3092\u5b9f\u73fe\u3057\u3064\u3064\u300168\u7a2e\u985e\u306e\u85ac\u7269\u3092\u9ad8\u7cbe\u5ea6\u3067\u691c\u51fa\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3057\u305f\u3002\u7de9\u885d\u6db2\u306e\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3084\u30b5\u30f3\u30d7\u30eb\u56de\u53ce\u7387\u306b\u95a2\u3059\u308b\u5177\u4f53\u7684\u306a\u5b9f\u9a13\u7d50\u679c\u3068\u5171\u306b\u3001SALLE\u3068SLE\u306b\u3088\u3063\u3066\u85ac\u7269\u5206\u6790\u306e\u52b9\u7387\u5316\u304c\u56f3\u308c\u305f\u3053\u3068\u3092\u8a73\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":24,"featured_media":6427,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[785],"tags":[],"industries-application":[2277,2276,2266],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2365],"ppma_author":[444],"class_list":["post-45333","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja","industries-application-forensics-toxicology-ja","industries-application-forensics-ja","industries-application-clinical-ja","resource-technique-ms-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}],"industries-application":[{"value":2277,"label":"\u6cd5\u4e2d\u6bd2\u5b66"},{"value":2276,"label":"\u6cd5\u533b\u5b66"},{"value":2266,"label":"\u81e8\u5e8a"}],"resource-technique":[{"value":2365,"label":"MS\/MS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFAN4466-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Samantha Herbick","author_link":"https:\/\/discover.restek.com\/ja\/author\/samantha-herbick\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":785,"category_count":88,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":444,"user_id":24,"is_guest":0,"slug":"samantha-herbick","display_name":"Samantha Herbick","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herbick-samantha.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herbick-samantha.jpg"},"author_category":"1","first_name":"Samantha","last_name":"Herbick","user_url":"https:\/\/www.linkedin.com\/in\/samantha-herbick-656378136\/","job_title":"Advanced Scientist, LC Solutions","description":"Samantha Herbick is an applications scientist within the LC Solutions Department at Restek. Her primary focus is on the development of applications in the toxicology and life science markets. She attended Duquesne University where she earned a bachelor\u2019s degree in Biochemistry and a master's degree in forensic science and law. Prior to joining Restek, Samantha worked as a scientist and method developer in a forensic toxicology lab. In this role, she performed analysis on toxicology casework and worked on the development and validation of new and existing assays using LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45333","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/24"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45333"}],"version-history":[{"count":10,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45333\/revisions"}],"predecessor-version":[{"id":81374,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45333\/revisions\/81374"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6427"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45333"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45333"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45333"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45333"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45333"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45333"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45333"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45333"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45333"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}