{"id":45334,"date":"2021-07-19T14:30:00","date_gmt":"2021-07-19T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/the-fundamentals-of-solid-phase-extraction-spe-japan\/"},"modified":"2026-01-13T21:34:44","modified_gmt":"2026-01-13T21:34:44","slug":"the-fundamentals-of-solid-phase-extraction-spe-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar3685-ja\/the-fundamentals-of-solid-phase-extraction-spe-japan","title":{"rendered":"\u56fa\u76f8\u62bd\u51fa (SPE) \u5b8c\u5168\u30ac\u30a4\u30c9\uff1a\u57fa\u790e\u304b\u3089\u5b66\u3076\u52b9\u7387\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3092\u884c\u308f\u305a\u306b\u3001\u3059\u3079\u3066\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u6b63\u78ba\u304b\u3064\u9ad8\u7cbe\u5ea6\u306b\u5206\u6790\u3067\u304d\u308b\u3053\u3068\u306f\u3001\u591a\u304f\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u304c\u671b\u3080\u7406\u60f3\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u307b\u3068\u3093\u3069\u306e\u5834\u5408\u3001\u3053\u306e\u7406\u60f3\u306f\u5b9f\u73fe\u304c\u96e3\u3057\u3044\u306e\u304c\u73fe\u5b9f\u3067\u3059\u3002\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u542b\u307e\u308c\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304c\u3001\u5b9a\u6027\u30fb\u5b9a\u91cf\u5206\u6790\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u3053\u3068\u304c\u3042\u308b\u304b\u3089\u3067\u3059\u3002\u7279\u306b\u8907\u96d1\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3084\u975e\u5e38\u306b\u4f4e\u6fc3\u5ea6\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u3092\u51e6\u7406\u3059\u308b\u5834\u5408\u3001\u5358\u7d14\u306a\u5e0c\u91c8\u3067\u306f\u5341\u5206\u306a\u52b9\u679c\u304c\u5f97\u3089\u308c\u305a\u3001\u6b63\u78ba\u304b\u3064\u7cbe\u5bc6\u306a\u5206\u6790\u304c\u56f0\u96e3\u306b\u306a\u308b\u3067\u3057\u3087\u3046\u3002\u3053\u306e\u3088\u3046\u306a\u5834\u5408\u3001\u3088\u308a\u7a4d\u6975\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u304c\u5fc5\u8981\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306b\u306f\u3055\u307e\u3056\u307e\u306a\u624b\u6cd5\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u305d\u306e\u4e2d\u3067\u3082\u5e83\u304f\u63a1\u7528\u3055\u308c\u3066\u3044\u308b\u306e\u304c\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff1aSolid Phase Extraction\uff09\u3067\u3059\u3002SPE\u306f\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u5206\u96e2\u3057\u3001\u6c5a\u67d3\u7269\u8cea\u306e\u5e72\u6e09\u3092\u53d7\u3051\u305a\u306b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u30e2\u30cb\u30bf\u30fc\u3059\u308b\u306e\u306b\u5f79\u7acb\u3064\u6280\u8853\u3067\u3059\u3002SPE\u306f\u3001\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u88c5\u7f6e\u3084\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306a\u3057\u3067\u884c\u3046\u3082\u306e\u3001\u3068\u8003\u3048\u308b\u3068\u308f\u304b\u308a\u3084\u3059\u3044\u3067\u3057\u3087\u3046\u3002\u306a\u305c\u306a\u3089\u3001SPE\u3067\u306f\u3001\u5206\u6790\u7528\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u306e\u5206\u96e2\u539f\u7406\u304c\u305d\u306e\u307e\u307e\u9069\u7528\u3055\u308c\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3055\u307e\u3056\u307e\u306a\u79fb\u52d5\u76f8\u3084\u56fa\u5b9a\u76f8\u304c\u3042\u308b\u306e\u3068\u540c\u69d8\u306b\u3001SPE\u88fd\u54c1\u3084\u30d7\u30ed\u30bb\u30b9\u306b\u3082\u3055\u307e\u3056\u307e\u306a\u9078\u629e\u80a2\u304c\u3042\u308a\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u5bfe\u5fdc\u3059\u308b\u5b8c\u74a7\u306a\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u306f\u5b58\u5728\u3057\u307e\u305b\u3093\u304c\u3001\u3055\u307e\u3056\u307e\u306a\u30b5\u30f3\u30d7\u30eb\u3084\u72b6\u6cc1\u306b\u5bfe\u5fdc\u3067\u304d\u308b\u3088\u3046\u3001\u591a\u69d8\u306a\u9078\u629e\u80a2\u304c\u5b58\u5728\u3059\u308b\u3053\u3068\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u306b\u3068\u3063\u3066\u5927\u304d\u306a\u52a9\u3051\u3068\u306a\u308b\u3067\u3057\u3087\u3046\u3002\u3057\u304b\u3057\u3001SPE\u306b\u4e0d\u6163\u308c\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u306b\u3068\u3063\u3066\u306f\u3001\u3053\u306e\u3088\u3046\u306a\u9078\u629e\u80a2\u306e\u591a\u3055\u304c\u6238\u60d1\u3044\u306e\u539f\u56e0\u3068\u306a\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6280\u8853\u3068\u3057\u3066\u5e83\u304f\u4f7f\u308f\u308c\u3066\u3044\u308bSPE\u306b\u3064\u3044\u3066\u3001\u57fa\u790e\u304b\u3089\u5fdc\u7528\u307e\u3067\u7c21\u5358\u304b\u3064\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002\u5177\u4f53\u7684\u306b\u306f\u3001SPE\u306e\u57fa\u672c\u7684\u306a\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0\u3084\u6226\u7565\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u7cbe\u88fd\u3084\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3001\u5206\u753b\u3084\u6fc3\u7e2e\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u307e\u305f\u3001SPE\u3067\u4f7f\u7528\u3055\u308c\u308b\u3055\u307e\u3056\u307e\u306a\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3084\u5145\u586b\u5264\u306e\u7279\u6027\u3001\u3055\u3089\u306b\u306f\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u6642\u306b\u8003\u616e\u3059\u3079\u304d\u8981\u7d20\u306b\u3064\u3044\u3066\u3082\u89e6\u308c\u307e\u3059\u3002\u3055\u3089\u306b\u3001SPE\u30e1\u30bd\u30c3\u30c9\u306e\u6700\u9069\u5316\u3092\u9032\u3081\u308b\u4e0a\u3067\u5f79\u7acb\u3064\u5b9f\u9a13\u306e\u9032\u3081\u65b9\u3084\u3001\u88fd\u54c1\u306b\u4ed8\u5c5e\u3059\u308b\u53d6\u6271\u8aac\u660e\u66f8\u306e\u6d3b\u7528\u65b9\u6cd5\u306b\u3064\u3044\u3066\u3082\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u56fa\u76f8\u62bd\u51fa \u2013 \u30b5\u30a4\u30ec\u30f3\u30c8\u30fb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u65b0\u3057\u3044SPE\u30d7\u30ed\u30c8\u30b3\u30eb\u3092\u4f5c\u6210\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u3001\u305d\u306e\u672c\u8cea\u3092\u300c\u691c\u51fa\u5668\u306e\u306a\u3044\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u300d\u3068\u7406\u89e3\u3057\u3066\u304a\u304f\u3068\u5b89\u5fc3\u3067\u3059\u3002SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u5185\u3067\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u304c\u884c\u308f\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u78ba\u8a8d\u3059\u308b\u691c\u51fa\u5668\u304c\u306a\u3044\u305f\u3081\u3001\u3053\u308c\u304c\u300c\u30b5\u30a4\u30ec\u30f3\u30c8\u30fb\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u300d\u3068\u547c\u3070\u308c\u308b\u7406\u7531\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u5168\u4f53\u3092\u30b7\u30b9\u30c6\u30e0\u3068\u6349\u3048\u305f\u5834\u5408\u3001SPE\u306b\u3082\u79fb\u52d5\u76f8\u3068\u56fa\u5b9a\u76f8\u304c\u5b58\u5728\u3057\u307e\u3059\u3002\u79fb\u52d5\u76f8\u306f\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u6c5a\u67d3\u7269\u8cea\u3092\u6d17\u6d44\u3057\u3001\u76ee\u7684\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u6eb6\u51fa\u3059\u308b\u305f\u3081\u306b\u4f7f\u7528\u3055\u308c\u308b\u6eb6\u5a92\u3067\u3059\u3002\u56fa\u5b9a\u76f8\u306fSPE\u306e\u5145\u586b\u5264\u3067\u3042\u308a\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u306e\u5316\u5b66\u7269\u8cea\u3092\u4fdd\u6301\u3059\u308b\u5f79\u5272\u3092\u6301\u3061\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001SPE\u30d7\u30ed\u30c8\u30b3\u30eb\u3082\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u96e2\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u7279\u306b\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3068\u5e72\u6e09\u3059\u308b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3068\u306e\u7406\u60f3\u7684\u306a\u5206\u96e2\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u4fdd\u6301\u3001\u9078\u629e\u6027\u3001\u5206\u96e2\u52b9\u7387\u3092\u8003\u616e\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u306b\u304a\u3044\u3066\u52b9\u7387\u7684\u306b\u5206\u96e2\u3092\u884c\u3046\u305f\u3081\u306b\u306f\u3001\u6d41\u901f\u3082\u91cd\u8981\u306a\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u4e00\u3064\u3067\u3059\u3002\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304cSPE\u306e\u5145\u586b\u5264\u306b\u5341\u5206\u306b\u4fdd\u6301\u3055\u308c\u305a\u3001\u4e0d\u8981\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3068\u4e00\u7dd2\u306b\u6d41\u51fa\u3057\u3066\u3057\u307e\u3046\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u3092\u907f\u3051\u308b\u305f\u3081\u306b\u306f\u3001\u5145\u586b\u5264\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u306e\u6a5f\u4f1a\u3092\u5341\u5206\u306b\u78ba\u4fdd\u3059\u308b\u6d41\u901f\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3064\u307e\u308a\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3068\u540c\u69d8\u306b\u3001SPE\u306b\u304a\u3044\u3066\u3082\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u6210\u5206\u3068\u79fb\u52d5\u76f8\u304a\u3088\u3073\u56fa\u5b9a\u76f8\u3068\u306e\u9593\u306b\u3055\u307e\u3056\u307e\u306a\u5f37\u3055\u306e\u76f8\u4e92\u4f5c\u7528\u3092\u751f\u307f\u51fa\u3059\u6761\u4ef6\u8a2d\u5b9a\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u3069\u306e\u3088\u3046\u306aSPE\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u304a\u3044\u3066\u3082\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6210\u5206\u69cb\u6210\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u9006\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u7269\u7406\u7684\u304a\u3088\u3073\u5316\u5b66\u7684\u7279\u6027\u3092\u628a\u63e1\u3057\u306a\u3051\u308c\u3070\u3001\u305d\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u6700\u9069\u306aSPE\u5145\u586b\u5264\u3084\u6eb6\u5a92\u3092\u9078\u3076\u3053\u3068\u306f\u56f0\u96e3\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SPE\u306e\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u88fd\u54c1\u306e\u4e3b\u8981\u306a\u76f8\u4e92\u4f5c\u7528\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u306b\u5fc5\u8981\u306a\u60c5\u5831\u304c\u660e\u78ba\u306b\u306a\u308a\u307e\u3059\u3002\u591a\u304f\u306eSPE\u88fd\u54c1\u3067\u306f\u3001\u6975\u6027\u3068\u30a4\u30aa\u30f3\u4ea4\u63db\u3068\u3044\u30462\u3064\u306e\u4e3b\u8981\u306a\u76f8\u4e92\u4f5c\u7528\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u6d3b\u7528\u3057\u305f\u3082\u306e\u304c\u591a\u3044\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002SPE\u306f\u901a\u5e38\u3001\u3053\u308c\u3089\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u4e00\u65b9\u307e\u305f\u306f\u4e21\u65b9\u3092\u5229\u7528\u3057\u3066\u304a\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u30cb\u30fc\u30ba\u306b\u5fdc\u3058\u3066\u3001\u3055\u307e\u3056\u307e\u306a\u6975\u6027\u3084\u30a4\u30aa\u30f3\u306e\u96fb\u8377\u72b6\u614b\u306b\u5fdc\u3058\u305f\u5206\u96e2\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u6975\u6027<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6975\u6027\u3092\u5229\u7528\u3057\u3066\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304b\u3089\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u5206\u96e2\u3059\u308b\u969b\u306b\u306f\u3001\u9806\u76f8\u30e2\u30fc\u30c9\u3068\u9006\u76f8\u30e2\u30fc\u30c9\u306e\u3044\u305a\u308c\u304b\u3092\u9078\u629e\u3057\u307e\u3059\u3002\u9806\u76f8\u30e2\u30fc\u30c9\u3067\u306f\u3001\u6975\u6027\u306e\u9ad8\u3044SPE\u5145\u586b\u5264\u3068\u975e\u6975\u6027\u306e\u79fb\u52d5\u76f8\u3092\u7d44\u307f\u5408\u308f\u305b\u3001\u6975\u6027\u6210\u5206\u3092\u4fdd\u6301\u3057\u306a\u304c\u3089\u975e\u6975\u6027\u6210\u5206\u3092\u6eb6\u51fa\u3055\u305b\u307e\u3059\u3002\u4e00\u65b9\u3001\u9006\u76f8\u30e2\u30fc\u30c9\u3067\u306f\u3001\u975e\u6975\u6027\u306eSPE\u5145\u586b\u5264\u3068\u6975\u6027\u306e\u9ad8\u3044\u79fb\u52d5\u76f8\u3092\u7d44\u307f\u5408\u308f\u305b\u3001\u758e\u6c34\u6027\u6210\u5206\u3092\u4fdd\u6301\u3057\u3064\u3064\u89aa\u6c34\u6027\u6210\u5206\u3092\u6eb6\u51fa\u3055\u305b\u307e\u3059\u3002\u5145\u586b\u5264\u306e\u4e2d\u306b\u306f\u3001\u6eb6\u5a92\u306e\u9078\u629e\u3068\u30b5\u30f3\u30d7\u30eb\u306b\u3088\u3063\u3066\u3001\u9806\u76f8\u30e2\u30fc\u30c9\u3068\u9006\u76f8\u30e2\u30fc\u30c9\u306e\u3069\u3061\u3089\u3068\u3057\u3066\u3082\u6a5f\u80fd\u3059\u308b\u3082\u306e\u3082\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001CarboPrep Plus\u3084Diol\u306a\u3069\u306e\u5145\u586b\u5264\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001SPE\u56fa\u5b9a\u76f8\u306b\u306f\u3055\u307e\u3056\u307e\u306a\u6975\u6027\u304c\u3042\u308a\u3001C18\u5145\u586b\u5264\u306fC8\u5145\u586b\u5264\u3088\u308a\u3082\u975e\u6975\u6027\u6210\u5206\u3092\u5f37\u304f\u4fdd\u6301\u3057\u307e\u3059\u3002\u79fb\u52d5\u76f8\u306e\u9078\u629e\u306b\u3088\u3063\u3066\u3082\u6975\u6027\u306e\u5e45\u3092\u5e83\u3052\u308b\u3053\u3068\u304c\u3067\u304d\u3001\u7de9\u885d\u6db2\u3084\u6dfb\u52a0\u5264\u306e\u7d44\u307f\u5408\u308f\u305b\u3067\u5206\u96e2\u306e\u5fae\u8abf\u6574\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6975\u6027\u304c\u5206\u96e2\u306e\u4e3b\u8981\u56e0\u3068\u306a\u308b\u5834\u5408\u3001\u300c\u4f3c\u305f\u8005\u540c\u58eb\u306f\u3088\u304f\u6eb6\u3051\u308b\uff08\u540c\u985e\u6eb6\u89e3\uff09\u300d\u3068\u3044\u3046\u683c\u8a00\u304c\u53c2\u8003\u306b\u306a\u308a\u307e\u3059\u3002\u5316\u5408\u7269\u304c\u79fb\u52d5\u76f8\u3084\u56fa\u5b9a\u76f8\u306e\u6975\u6027\u306b\u4f3c\u3066\u3044\u308b\u307b\u3069\u3001\u3088\u308a\u5f37\u3044\u76f8\u4e92\u4f5c\u7528\u304c\u671f\u5f85\u3067\u304d\u307e\u3059\u3002\u56fa\u5b9a\u76f8\u3068\u306e\u5f37\u3044\u76f8\u4e92\u4f5c\u7528\u306f\u3001SPE\u5145\u586b\u5264\u4e0a\u3067\u306e\u4fdd\u6301\u306e\u5897\u52a0\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u304c\u3001\u79fb\u52d5\u76f8\u3068\u306e\u5f37\u3044\u76f8\u4e92\u4f5c\u7528\u306f\u3001\u4fdd\u6301\u306e\u6e1b\u5c11\u306b\u3064\u306a\u304c\u308a\u3001\u6210\u5206\u306e\u65e9\u671f\u6eb6\u51fa\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u30a4\u30aa\u30f3\u4ea4\u63db<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u6210\u5206\u304c\u5e38\u306b\u96fb\u8377\u3092\u5e2f\u3073\u3066\u3044\u308b\u5834\u5408\u3084\u3001\u6eb6\u89e3\u6db2\u306e\u6761\u4ef6\u306b\u3088\u3063\u3066\u96fb\u8377\u3092\u5e2f\u3073\u308b\u5834\u5408\u3001SPE\u5145\u586b\u5264\u3082\u7279\u5b9a\u306e\u96fb\u8377\u3092\u5e2f\u3073\u308b\u3053\u3068\u3067\u3001\u5206\u6790\u6210\u5206\u3068\u306e\u9593\u306b\u96fb\u6c17\u7684\u306a\u76f8\u4e92\u4f5c\u7528\u304c\u751f\u3058\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u53e4\u5178\u7684\u306a\u9759\u96fb\u5f15\u529b\u3092\u5fdc\u7528\u3057\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3084\u5206\u6790\u6210\u5206\u540c\u58eb\u306e\u52b9\u679c\u7684\u306a\u5206\u96e2\u3092\u884c\u3046\u306e\u304c\u30a4\u30aa\u30f3\u4ea4\u63db\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6975\u6027\u3084\u540c\u985e\u6eb6\u89e3\u3068\u3044\u3063\u305f\u76f8\u4e92\u4f5c\u7528\u3092\u5229\u7528\u3057\u305f\u5206\u96e2\u30e2\u30c7\u30eb\u3068\u306f\u7570\u306a\u308a\u3001\u96fb\u8377\u72b6\u614b\u306b\u3088\u308b\u76f8\u4e92\u4f5c\u7528\u3092\u5229\u7528\u3057\u305f\u30a4\u30aa\u30f3\u4ea4\u63db\u306f\u3001\u300c\u9006\u306e\u6027\u8cea\u3092\u6301\u3064\u3082\u306e\u304c\u4f5c\u7528\u3057\u3042\u3046\u300d\u3068\u3044\u3046\u6cd5\u5247\u306b\u5f93\u3044\u3001\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u3068\u967d\u30a4\u30aa\u30f3\u4ea4\u63db\u306e2\u3064\u306e\u4e3b\u8981\u306a\u30d7\u30ed\u30bb\u30b9\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305a\u3001\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002\u3053\u306e\u30d7\u30ed\u30bb\u30b9\u3067\u306f\u3001\u30d7\u30e9\u30b9\u306e\u96fb\u8377\u3092\u5e2f\u3073\u305fSPE\u5145\u586b\u5264\uff08\u967d\u30a4\u30aa\u30f3\u4ea4\u63db\u6a39\u8102\uff09\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002SPE\u5145\u586b\u5264\u306e\u8868\u9762\u306b\u306f\u30de\u30a4\u30ca\u30b9\u306e\u96fb\u8377\u3092\u6301\u3064\u9670\u30a4\u30aa\u30f3\u304c\u5f15\u304d\u5bc4\u305b\u3089\u308c\u3001\u7d50\u5408\u3057\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u30de\u30a4\u30ca\u30b9\u306e\u96fb\u8377\u3092\u5e2f\u3073\u305f\u5206\u6790\u6210\u5206\u304c\u5b58\u5728\u3059\u308b\u5834\u5408\u3001\u305d\u306e\u6210\u5206\u304c\u52a0\u308f\u308b\u3068\u3001\u5143\u3005\u7d50\u5408\u3057\u3066\u3044\u305f\u9670\u30a4\u30aa\u30f3\u304c\u7f6e\u304d\u63db\u3048\u3089\u308c\u3001\u5206\u6790\u6210\u5206\u304cSPE\u5145\u586b\u5264\u306b\u4fdd\u6301\u3055\u308c\u308b\u3068\u3044\u3046\u30e1\u30ab\u30cb\u30ba\u30e0\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u65b9\u3001\u967d\u30a4\u30aa\u30f3\u4ea4\u63db\u3067\u306f\u3001\u8ca0\u306e\u96fb\u8377\u3092\u5e2f\u3073\u305fSPE\u5145\u586b\u5264\uff08\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u6a39\u8102\uff09\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u8ca0\u306e\u96fb\u8377\u3092\u6301\u3064SPE\u5145\u586b\u5264\u306e\u8868\u9762\u306b\u306f\u30d7\u30e9\u30b9\u306e\u96fb\u8377\u3092\u5e2f\u3073\u305f\u967d\u30a4\u30aa\u30f3\u304c\u5f15\u304d\u5bc4\u305b\u3089\u308c\u3001\u7d50\u5408\u3057\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u30d7\u30e9\u30b9\u306e\u96fb\u8377\u3092\u5e2f\u3073\u305f\u5206\u6790\u6210\u5206\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u3068\u3001\u305d\u306e\u6210\u5206\u304c\u52a0\u308f\u3063\u305f\u969b\u306b\u3001\u5143\u3005\u7d50\u5408\u3057\u3066\u3044\u305f\u967d\u30a4\u30aa\u30f3\u304c\u7f6e\u304d\u63db\u3048\u3089\u308c\u3001\u5206\u6790\u6210\u5206\u304cSPE\u5145\u586b\u5264\u306b\u4fdd\u6301\u3055\u308c\u308b\u3068\u3044\u3046\u4ed5\u7d44\u307f\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3061\u306a\u307f\u306b\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u3067\u306fSPE\u5145\u586b\u5264\u3068\u540c\u3058\u96fb\u8377\u3092\u6301\u3064\u5316\u5408\u7269\u306f\u76f8\u4e92\u4f5c\u7528\u304c\u767a\u751f\u305b\u305a\u4fdd\u6301\u3055\u308c\u307e\u305b\u3093\u3002\u307e\u305f\u5145\u586b\u5264\u306b\u30a4\u30aa\u30f3\u4ea4\u63db\u4ee5\u5916\u306e\u7279\u6027\u304c\u306a\u3044\u9650\u308a\u3001\u4e2d\u6027\u7a2e\u3082\u307b\u3068\u3069\u3093\u3069\u4fdd\u6301\u3055\u308c\u307e\u305b\u3093\u3002\u3053\u306e\u3088\u3046\u306b\u3001\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\u3068\u967d\u30a4\u30aa\u30f3\u4ea4\u63db\u306f\u305d\u308c\u305e\u308c\u7570\u306a\u308b\u96fb\u8377\u3092\u5e2f\u3073\u305f\u5145\u586b\u5264\u3068\u5206\u6790\u6210\u5206\u304c\u76f8\u4e92\u4f5c\u7528\u3059\u308b\u30d7\u30ed\u30bb\u30b9\u3067\u3042\u308a\u3001\u4e21\u8005\u304c\u9023\u643a\u3057\u3066\u3055\u307e\u3056\u307e\u306a\u5206\u6790\u76ee\u7684\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u307e\u3059\u3002\u30a4\u30aa\u30f3\u4ea4\u63db\u30d7\u30ed\u30bb\u30b9\u306f\u3001\u6eb6\u6db2\u306epH\u3084\u30a4\u30aa\u30f3\u5f37\u5ea6\u306a\u3069\u306e\u6761\u4ef6\u306b\u5f37\u304f\u4f9d\u5b58\u3057\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u6eb6\u6db2\u306epH\u304c\u5909\u5316\u3059\u308b\u3068\u3001\u5206\u6790\u6210\u5206\u3084\u5145\u586b\u5264\u306e\u96fb\u8377\u304c\u5909\u308f\u308a\u3001\u4fdd\u6301\u306e\u5f37\u3055\u3084\u6eb6\u51fa\u6761\u4ef6\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u30a4\u30aa\u30f3\u4ea4\u63dbSPE\u3067\u306f\u3001\u5206\u6790\u6210\u5206\u306epKa\u3084\u6eb6\u6db2\u306epH\u3092\u8003\u616e\u3057\u3001\u6700\u9069\u306a\u6761\u4ef6\u3092\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a4\u30aa\u30f3\u4ea4\u63dbSPE\u3067\u306f\u3001\u5206\u6790\u6210\u5206\u3068\u5145\u586b\u5264\u306e\u96fb\u8377\u306e\u300c\u5f37\u3055\u300d\u306b\u3082\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u5206\u6790\u6210\u5206\u304c\u6eb6\u6db2\u306epH\u306b\u95a2\u4fc2\u306a\u304f\u5e38\u306b\u96fb\u8377\u3092\u5e2f\u3073\u3066\u3044\u308b\u5834\u5408\u3001\u305d\u308c\u306f\u300c\u5f37\u3044\u30a4\u30aa\u30f3\u6027\u300d\u3092\u6301\u3064\u3068\u3055\u308c\u307e\u3059\u3002\u4e00\u65b9\u3001\u7279\u5b9a\u306epH\u6761\u4ef6\u4e0b\u3067\u306e\u307f\u96fb\u8377\u3092\u6301\u3064\u5834\u5408\u306f\u300c\u5f31\u3044\u30a4\u30aa\u30f3\u6027\u300d\u3092\u6301\u3064\u3068\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u3092\u57fa\u306b\u3057\u3066\u3001\u5206\u6790\u6210\u5206\u306e\u96fb\u8377\u7279\u6027\u306b\u5fdc\u3058\u305f\u5145\u586b\u5264\u306e\u9078\u629e\u304c\u884c\u308f\u308c\u307e\u3059\u3002\u5177\u4f53\u7684\u306b\u306f\u3001\u300c\u5f37\u3044\u30a4\u30aa\u30f3\u6027\u300d\u3092\u6301\u3064\u5206\u6790\u6210\u5206\u306b\u306f\u300c\u5f31\u3044\u300d\u30a4\u30aa\u30f3\u4ea4\u63dbSPE\u5145\u586b\u5264\u3092\u3001\u300c\u5f31\u3044\u30a4\u30aa\u30f3\u6027\u300d\u3092\u6301\u3064\u5206\u6790\u6210\u5206\u306b\u306f\u300c\u5f37\u3044\u300d\u30a4\u30aa\u30f3\u4ea4\u63db\u5145\u586b\u5264\u3092\u9078\u629e\u3059\u308b\u306e\u304c\u4e00\u822c\u7684\u3067\u3059\u3002\u5f37\u3044\u5206\u6790\u6210\u5206\u3068\u5f37\u3044\u5145\u586b\u5264\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3068\u3001\u7d50\u5408\u529b\u304c\u5f37\u3059\u304e\u3066\u6eb6\u51fa\u304c\u56f0\u96e3\u306b\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u540c\u69d8\u306b\u3001\u5f31\u3044\u5206\u6790\u6210\u5206\u3068\u5f31\u3044\u5145\u586b\u5264\u306e\u7d44\u307f\u5408\u308f\u305b\u3067\u306f\u3001\u5206\u6790\u6210\u5206\u306e\u4fdd\u6301\u304c\u4e0d\u5341\u5206\u3068\u306a\u308a\u3001\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3068\u3048\u3070\u3001SPE\u5145\u586b\u5264\u306b\u4fdd\u6301\u3055\u305b\u305f\u3044\u5f31\u9178\u6027\u5316\u5408\u7269\uff08pKa 2-8\uff09\u304c\u542b\u307e\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u5834\u5408\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u52b9\u679c\u7684\u306b\u5229\u7528\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u5206\u6790\u6210\u5206\u3068\u5145\u586b\u5264\u306e\u4e21\u65b9\u304c\u8377\u96fb\u72b6\u614b\u306b\u3042\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u5f37\u3044\u30a4\u30aa\u30f3\u4ea4\u63db\u30bf\u30a4\u30d7\u306e\u5145\u586b\u5264\u3092\u9078\u629e\u3057\u3001\u6eb6\u6db2\u306epH\u3092\u5206\u6790\u6210\u5206\u306epKa\u304b\u3089\u7d042\u7a0b\u5ea6\u9ad8\u3044\u5024\u306b\u8a2d\u5b9a\u3057\u307e\u3059\u3002\u3053\u3046\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u6790\u6210\u5206\u304c\u30a4\u30aa\u30f3\u4ea4\u63db\u5145\u586b\u5264\u306b\u3057\u3063\u304b\u308a\u3068\u4fdd\u6301\u3055\u308c\u308b\u72b6\u614b\u3092\u78ba\u4fdd\u3067\u304d\u307e\u3059\u3002\u5206\u6790\u6210\u5206\u306e\u4fdd\u6301\u3092\u89e3\u9664\u3057\u3001\u6eb6\u51fa\u3055\u305b\u308b\u306b\u306f\u3001\u6eb6\u6db2\u306epH\u3092\u8abf\u6574\uff08pKa\u304b\u30892\u7a0b\u5ea6\u4f4e\u304f\uff09\u3057\u3066\u3001\u5206\u6790\u6210\u5206\u304c\u4e2d\u6027\u7a2e\u3068\u306a\u308b\u3088\u3046\u306b\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u5145\u586b\u5264\u304b\u3089\u89e3\u96e2\u3057\u3001\u6eb6\u51fa\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u65b9\u3001\u30b5\u30f3\u30d7\u30eb\u306b\u5f31\u5869\u57fa\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u5834\u5408\u3001\u5f31\u5869\u57fa\u306fpH\u304c\u4f4e\u4e0b\u3059\u308b\u3068\u30d7\u30e9\u30b9\u306e\u96fb\u8377\u3092\u6301\u3064\u3088\u3046\u306b\u306a\u308a\u3001\u967d\u30a4\u30aa\u30f3\u4ea4\u63db\u304c\u884c\u308f\u308c\u307e\u3059\u3002\u3053\u306e\u5834\u5408\u3001\u5f37\u967d\u30a4\u30aa\u30f3\u4ea4\u63db\u30bf\u30a4\u30d7\u306e\u5145\u586b\u5264\u3092\u9078\u629e\u3057\u3001\u5206\u6790\u6210\u5206\u304c\u5e2f\u96fb\u3059\u308b\u3088\u3046\u306b\u6eb6\u6db2\u306epH\uff08pKa-2\uff09\u3092\u8abf\u6574\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a4\u30aa\u30f3\u4ea4\u63db\u306f\u8907\u96d1\u306a\u30d7\u30ed\u30bb\u30b9\u3067\u3059\u304c\u3001\u7279\u306b\u6975\u6027\u76f8\u4e92\u4f5c\u7528\u3068\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u975e\u5e38\u306b\u9ad8\u3044\u9078\u629e\u6027\u3092\u6301\u3063\u305f\u8907\u96d1\u306a\u30de\u30c8\u30ea\u30af\u30b9\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u3082\u9069\u7528\u3067\u304d\u308bSPE\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\uff08\u30df\u30c3\u30af\u30b9\u30e2\u30fc\u30c9SPE\uff09\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u96e2\u6319\u52d5\u306e\u5b9a\u91cf\u5316\u304c\u96e3\u3057\u3044\u8868\u9762\u76f8\u4e92\u4f5c\u7528<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5145\u586b\u5264\u306e\u4fdd\u6301\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u306e\u3042\u308b\u3001\u5206\u96e2\u6319\u52d5\u306e\u4e88\u6e2c\u304c\u96e3\u3057\u3044\u8868\u9762\u76f8\u4e92\u4f5c\u7528\u306b\u306f\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001C18\u30b7\u30ea\u30ab\u306b\u304a\u3044\u3066\u30b7\u30ea\u30ab\u8868\u9762\u306b\u591a\u304f\u306e\u30b7\u30e9\u30ce\u30fc\u30eb\uff08Si-OH\uff09\u57fa\u304c\u5b58\u5728\u3059\u308b\u5834\u5408\u3001C18\u30ea\u30ac\u30f3\u30c9\u306b\u3088\u308b\u758e\u6c34\u6027\u76f8\u4e92\u4f5c\u7528\u3060\u3051\u3067\u306a\u304f\u3001\u30b7\u30e9\u30ce\u30fc\u30eb\u57fa\u3068\u306e\u5f37\u3044\u76f8\u4e92\u4f5c\u7528\u304c\u767a\u751f\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u30b7\u30ea\u30ab\u5145\u586b\u5264\u306e\u300c\u30a8\u30f3\u30c9\u30ad\u30e3\u30c3\u30d7\u51e6\u7406\u300d\u306e\u6709\u7121\u304c\u91cd\u8981\u306b\u306a\u308b\u30b1\u30fc\u30b9\u3082\u3042\u308a\u307e\u3059\u3002\u30a8\u30f3\u30c9\u30ad\u30e3\u30c3\u30d7\u51e6\u7406\u306b\u3088\u308a\u3001\u9732\u51fa\u3057\u305f\u30b7\u30e9\u30ce\u30fc\u30eb\u57fa\u3092\u30e1\u30c1\u30eb\u57fa\u306b\u7f6e\u63db\u3057\u3001\u5f37\u3044\u76f8\u4e92\u4f5c\u7528\u3092\u6291\u5236\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d9\u30f3\u30c0\u30fc\u9593\u3001\u3042\u308b\u3044\u306f\u540c\u4e00\u30d9\u30f3\u30c0\u30fc\u306e\u88fd\u54c1\u30ed\u30c3\u30c8\u9593\u3067\u3082\u3001\u88fd\u54c1\u306e\u5206\u96e2\u7279\u6027\u306b\u9055\u3044\u304c\u751f\u3058\u308b\u3053\u3068\u304c\u3042\u308b\u305f\u3081\u3001\u5207\u308a\u66ff\u3048\u3084\u30ed\u30c3\u30c8\u5909\u66f4\u6642\u306b\u306f\u4e8b\u524d\u306e\u6027\u80fd\u78ba\u8a8d\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SPE\u306e\u76ee\u6a19\u3068\u6226\u7565<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u306e\u57fa\u672c\u7684\u306a\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0\u306b\u6163\u308c\u305f\u3089\u3001\u6b21\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001SPE\u306e\u76ee\u7684\u306b\u3064\u3044\u3066\u7406\u89e3\u3092\u6df1\u3081\u307e\u3057\u3087\u3046\u3002\u4e00\u822c\u7684\u306b\u306f\u6b21\u306e\u3044\u305a\u308c\u304b\u306e\u76ee\u7684\u3067SPE\u3092\u884c\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u7cbe\u88fd\uff0f\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u304f\u306e\u5834\u5408\u3001SPE\u306e\u4e3b\u306a\u76ee\u7684\u306f\u30b5\u30f3\u30d7\u30eb\u306e\u7cbe\u88fd\u3084\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3067\u3059\u3002\u7cbe\u88fd\u3084\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u306f\u3001\u4ed6\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304b\u3089\u5206\u6790\u6210\u5206\u3092\u9078\u629e\u7684\u306b\u5206\u96e2\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u6790\u306e\u59a8\u5bb3\u3092\u9632\u3050\u3053\u3068\u304c\u76ee\u7684\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u593e\u96d1\u6210\u5206\u3084\u6c5a\u67d3\u6210\u5206\u304b\u3089\u5206\u6790\u6210\u5206\u3092\u9078\u629e\u7684\u306b\u5206\u96e2\u3059\u308b\u3053\u3068\u306f\u3001\u5f8c\u306e\u5206\u96e2\u5206\u6790\u306b\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u306e\u593e\u96d1\u6210\u5206\u3068\u306e\u5171\u6eb6\u51fa\u306e\u9632\u6b62\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u5171\u6eb6\u51fa\u306f\u5206\u6790\u306b\u304a\u3044\u3066\u671b\u307e\u3057\u304f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u305d\u306e\u5f71\u97ff\u306f\u4f7f\u7528\u3059\u308b\u691c\u51fa\u5668\u3084\u5206\u6790\u6761\u4ef6\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002GC-FID\u3084LC-UV\u3068\u3044\u3063\u305f\u5b9a\u6027\u6027\u80fd\u306b\u9650\u754c\u304c\u3042\u308b\u691c\u51fa\u5668\u3067\u306f\u3001\u5171\u6eb6\u51fa\u306b\u3088\u308a\u593e\u96d1\u6210\u5206\u3068\u5206\u6790\u6210\u5206\u304c\u533a\u5225\u3067\u304d\u306a\u304f\u306a\u308a\u3001\u5b9a\u91cf\u304c\u96e3\u3057\u304f\u306a\u3063\u305f\u308a\u8aa4\u540c\u5b9a\u3092\u5f15\u304d\u8d77\u3053\u3059\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">MS\u3084MS\/MS\u691c\u51fa\u5668\u3067\u3082\u5171\u6eb6\u51fa\u306e\u554f\u984c\u306f\u767a\u751f\u3057\u307e\u3059\u3002MS\u306f\u30b9\u30da\u30af\u30c8\u30eb\u306b\u3088\u308b\u5b9a\u6027\u6027\u80fd\u3092\u6709\u3057\u307e\u3059\u304c\u3001\u5171\u6eb6\u51fa\u3059\u308b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304c\u5206\u6790\u6210\u5206\u306e\u30a4\u30aa\u30f3\u5316\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u3001\u30b7\u30b0\u30ca\u30eb\u304c\u904e\u5c0f\u8a55\u4fa1\u307e\u305f\u306f\u904e\u5927\u8a55\u4fa1\u3055\u308c\u308b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u52b9\u679c\u304c\u751f\u3058\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u5f71\u97ff\u3092\u88dc\u6b63\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30d6\u30e9\u30f3\u30af\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u7528\u3044\u305f\u691c\u91cf\u7dda\u7528\u6a19\u6e96\u8a66\u6599\u306b\u3088\u308b\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u304c\u3001SPE\u3092\u7528\u3044\u305f\u524d\u51e6\u7406\u3082\u6975\u3081\u3066\u6709\u52b9\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304c\u6eb6\u51fa\u3059\u308b\u3068\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c\u3084\u30d4\u30fc\u30af\u89e3\u6790\u306e\u4e0d\u6b63\u78ba\u3055\u3092\u62db\u304f\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304c\u6bd4\u8f03\u7684\u5358\u7d14\u3067\u3001\u5206\u6790\u6210\u5206\u304c\u5c11\u306a\u3044\u5834\u5408\u306b\u306f\u3001\u524d\u51e6\u7406\u3092\u884c\u308f\u305a\u3001\u5206\u6790\u30ab\u30e9\u30e0\u3067\u306e\u5206\u96e2\u3092\u6700\u9069\u5316\u3059\u308b\u3060\u3051\u3067\u5341\u5206\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u304c\u3001\u8907\u96d1\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3084\u591a\u304f\u306e\u5206\u6790\u6210\u5206\u304c\u3042\u308b\u5834\u5408\u3001SPE\u306b\u3088\u308b\u9078\u629e\u7684\u306a\u5206\u96e2\u304c\u89e3\u6c7a\u7b56\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u5e72\u6e09\u306b\u3088\u308b\u4e0d\u8981\u306a\u76f8\u4e92\u4f5c\u7528\u306e\u9632\u6b62\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306f\u5206\u6790\u6210\u5206\u3068\u4e00\u7dd2\u306b\u6eb6\u51fa\u3057\u3066\u691c\u51fa\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u4ee5\u5916\u306b\u3001\u88c5\u7f6e\u5185\u306b\u6b8b\u7559\u3057\u3066\u4e0d\u8981\u306a\u76f8\u4e92\u4f5c\u7528\u3092\u5f15\u304d\u8d77\u3053\u3059\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u524d\u306e\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u6b8b\u7559\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304c\u3001\u6b21\u306e\u5206\u6790\u30b5\u30f3\u30d7\u30eb\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u3088\u3046\u306a\u30b1\u30fc\u30b9\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5206\u6790\u6210\u5206\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u6b6a\u3080\uff08\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\uff09\u3068\u3044\u3063\u305f\u4fdd\u6301\u6642\u9593\u30b7\u30d5\u30c8\u306e\u554f\u984c\u304c\u767a\u751f\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u30b7\u30b9\u30c6\u30e0\u306b\u6b8b\u7559\u3057\u305f\u6210\u5206\u304c\u5206\u6790\u6210\u5206\u3068\u5316\u5b66\u53cd\u5fdc\u3057\u5206\u89e3\u751f\u6210\u7269\u304c\u751f\u6210\u3055\u308c\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u5206\u89e3\u751f\u6210\u7269\u304c\u5206\u6790\u30ab\u30e9\u30e0\u306e\u624b\u524d\u3067\u767a\u751f\u3059\u308b\u3068\u3001\u65b0\u305f\u306a\u30d4\u30fc\u30af\u304c\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u4e0a\u306b\u73fe\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u5206\u89e3\u751f\u6210\u7269\u304c\u5206\u6790\u30ab\u30e9\u30e0\u5185\u3067\u767a\u751f\u3059\u308b\u3068\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u6b6a\u307f\u306b\u3064\u306a\u304c\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3001\u88c5\u7f6e\u5185\u90e8\u306e\u6c5a\u67d3\u304c\u30c7\u30fc\u30bf\u54c1\u8cea\u306b\u60aa\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u3053\u3068\u3082\u3042\u308b\u305f\u3081\u3001\u3042\u3089\u304b\u3058\u3081\u53d6\u308a\u9664\u304f\u3053\u3068\u304c\u7406\u60f3\u7684\u3067\u3059\u3002 \u30b5\u30f3\u30d7\u30eb\u5e0c\u91c8\u306b\u3088\u3063\u3066\u3053\u308c\u3089\u306e\u5f71\u97ff\u3092\u8efd\u6e1b\u3059\u308b\u3053\u3068\u3082\u3067\u304d\u307e\u3059\u304c\u3001\u5206\u6790\u6210\u5206\u3082\u5e0c\u91c8\u3055\u308c\u308b\u305f\u3081\u3001\u5e0c\u91c8\u304c\u89e3\u6c7a\u7b56\u3068\u306a\u3089\u306a\u3044\u3068\u304d\u306f\u3001SPE\u304c\u6b21\u306e\u826f\u3044\u9078\u629e\u80a2\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\">\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u84c4\u7a4d\u306b\u3088\u308b\u88c5\u7f6e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306e\u56de\u907f\uff1a<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u88c5\u7f6e\u5185\u306b\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6c5a\u67d3\u304c\u84c4\u7a4d\u3059\u308b\u3068\u3001\u6642\u9593\u306e\u7d4c\u904e\u3068\u3068\u3082\u306b\u554f\u984c\u304c\u767a\u751f\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u5b9a\u671f\u7684\u306a\u4e88\u9632\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u306e\u9593\u306b\u30c8\u30e9\u30d6\u30eb\u304c\u767a\u751f\u3059\u308b\u3068\u3001\u88c5\u7f6e\u306e\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3084\u518d\u6821\u6b63\u304c\u5fc5\u8981\u306b\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002SPE\u3092\u7528\u3044\u305f\u7cbe\u88fd\u3084\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u306f\u3001\u3053\u308c\u3089\u306e\u554f\u984c\u3092\u672a\u7136\u306b\u9632\u3050\u305f\u3081\u306e\u826f\u3044\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u753b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9a\u91cf\u5206\u6790\u306e\u524d\u306b\u5206\u6790\u6210\u5206\u540c\u58eb\u3092\u5206\u3051\u3066\u3057\u307e\u3046\u3053\u3068\u304c\u6709\u52b9\u306a\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u6642\u306b\u5f79\u7acb\u3064\u306e\u304c\u5206\u753b\u3068\u3044\u3046\u8003\u3048\u65b9\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f8b\u3048\u3070\u3001\u30b5\u30f3\u30d7\u30eb\u306b\u7570\u306a\u308b\u5316\u5408\u7269\u30af\u30e9\u30b9\u304c\u542b\u307e\u308c\u3066\u3044\u3066\u3001\u305d\u308c\u305e\u308c\u306b\u5c02\u7528\u306e\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u304c\u5fc5\u8981\u3068\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\uff08\u4f8b\uff1a\u62bd\u51fa\u53ef\u80fd\u306a\u77f3\u6cb9\u70ad\u5316\u6c34\u7d20\uff08EPH\uff09\u5206\u6790\u306b\u304a\u3051\u308b\u8102\u80aa\u65cf\u5316\u5408\u7269\u3068\u82b3\u9999\u65cf\u5316\u5408\u7269\uff09\u3002\u3053\u306e\u3088\u3046\u306a\u5834\u5408\u3001SPE\u3092\u5229\u7528\u3057\u3066\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u5927\u307e\u304b\u306b\u5206\u753b\u3059\u308b\u3053\u3068\u3067\u3001\u305d\u306e\u5f8c\u306e\u5206\u6790\u4f5c\u696d\u3092\u30b9\u30e0\u30fc\u30ba\u306b\u884c\u3048\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u6fc3\u7e2e<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a1\u30fc\u306f\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u6fc3\u5ea6\u304c\u6a5f\u5668\u306e\u5b9a\u91cf\u9650\u754c\u3092\u4e0b\u56de\u308b\u3088\u3046\u306a\u3001\u975e\u5e38\u306b\u4f4e\u6fc3\u5ea6\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u691c\u51fa\u30fb\u5b9a\u91cf\u3059\u308b\u5fc5\u8981\u306b\u8feb\u3089\u308c\u308b\u3053\u3068\u304c\u3088\u304f\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u5834\u5408\u3001SPE\u30e1\u30bd\u30c3\u30c9\u3092\u5229\u7528\u3057\u3066\u30b5\u30f3\u30d7\u30eb\u3092\u6fc3\u7e2e\u3059\u308b\u3053\u3068\u304c\u6709\u52b9\u3067\u3059\u3002SPE\u3067\u306f\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u52b9\u679c\u7684\u306b\u4fdd\u6301\u3057\u3064\u3064\u3001\u4e0d\u8981\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u53d6\u308a\u9664\u304f\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u6fc3\u7e2e\u3055\u308c\u305f\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306f\u3001\u6700\u7d42\u7684\u306b\u6eb6\u51fa\u6eb6\u5a92\u3067\u56de\u53ce\u3057\u3001\u691c\u51fa\u53ef\u80fd\u306a\u6fc3\u5ea6\u306b\u8abf\u6574\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">SPE\u6226\u7565<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u6226\u7565\u3092\u7acb\u3066\u308b\u969b\u306b\u306f\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u6319\u52d5\u3092\u3069\u306e\u3088\u3046\u306b\u5236\u5fa1\u3057\u305f\u3044\u304b\u8003\u3048\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002SPE\u3067\u306f\u3001\u5145\u586b\u5264\u306b\u4fdd\u6301\u3055\u308c\u308b\u6210\u5206\u3068\u3001\u4fdd\u6301\u3055\u308c\u305a\u306b\u6eb6\u51fa\u3055\u308c\u308b\u6210\u5206\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u9055\u3044\u3092\u5229\u7528\u3057\u3066\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u52b9\u7387\u7684\u306b\u5206\u96e2\u30fb\u6fc3\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e3b\u306a\u76ee\u6a19\u304c\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u304b\u3089\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u5206\u96e2\u3059\u308b\u3053\u3068\u306a\u3089\u3001\u300c\u5206\u6790\u5bfe\u8c61\u6210\u5206\u30d1\u30b9\u30b9\u30eb\u30fc\u300d\u30a2\u30d7\u30ed\u30fc\u30c1\u304c\u6709\u52b9\u3067\u3059\u3002\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u5145\u586b\u5264\u306b\u5f37\u304f\u4fdd\u6301\u3055\u305b\u306a\u304c\u3089\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306f\u307b\u3068\u3093\u3069\u4fdd\u6301\u3055\u305b\u305a\u306b\u6eb6\u51fa\u3055\u305b\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u65b9\u3001\u76ee\u6a19\u304c\u6fc3\u7e2e\u3067\u3042\u3063\u305f\u308a\u3001\u307e\u305f\u3001\u30d1\u30b9\u30b9\u30eb\u30fc\u304c\u3046\u307e\u304f\u3044\u304b\u306a\u3044\u6210\u5206\u3067\u306f\u3001\u300c\u5206\u6790\u5bfe\u8c61\u6210\u5206\u30ad\u30e3\u30d7\u30c1\u30e3\u30fc\u300d\u30a2\u30d7\u30ed\u30fc\u30c1\u304c\u6709\u52b9\u3067\u3059\u3002\u5145\u586b\u5264\u306b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u3057\u3063\u304b\u308a\u3068\u4fdd\u6301\u3055\u305b\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u6210\u5206\u3092\u6d17\u3044\u6d41\u3057\u305f\u5f8c\u3001\u5f37\u529b\u306a\u6eb6\u51fa\u6eb6\u5a92\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u5206\u96e2\u30fb\u6fc3\u7e2e\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SPE\u306e\u30d5\u30a9\u30fc\u30de\u30c3\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3059\u308b\u969b\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u7279\u6027\u3092\u7406\u89e3\u3057\u3001\u76ee\u6a19\u3092\u660e\u78ba\u306b\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u5e72\u6e09\u7269\u8cea\u304b\u3089\u52b9\u679c\u7684\u306b\u5206\u96e2\u3059\u308b\u305f\u3081\u306b\u3001\u9069\u5207\u306a\u5145\u586b\u5264\u3068\u6eb6\u5a92\u3092\u9078\u3076\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001SPE\u306e\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u9078\u629e\u3082\u91cd\u8981\u306a\u6c7a\u5b9a\u8981\u7d20\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u306b\u4ee3\u8868\u7684\u306aSPE\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\uff1a<\/strong> \u6700\u3082\u4e00\u822c\u7684\u306aSPE\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3067\u3042\u308a\u3001\u624b\u52d5\u304a\u3088\u3073\u81ea\u52d5\u30b7\u30b9\u30c6\u30e0\u3067\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3001\u5145\u586b\u5264\u3092\u56fa\u5b9a\u3059\u308b\u30d5\u30ea\u30c3\u30c8\u306e\u9593\u306b1\u3064\u307e\u305f\u306f\u8907\u6570\u306e\u5145\u586b\u5264\u3068\u3001\u5145\u586b\u5264\u4e0a\u90e8\u306b\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u6eb6\u5a92\u307e\u305f\u306f\u6eb6\u51fa\u6eb6\u5a92\u3092\u8ffd\u52a0\u3059\u308b\u30ea\u30b6\u30fc\u30d0\u3067\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30ea\u30b6\u30fc\u30d0\u306e\u30b5\u30a4\u30ba\u304c\u5206\u6790\u3059\u308b\u30b5\u30f3\u30d7\u30eb\u306e\u4f53\u7a4d\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u304b\u3001\u5145\u586b\u5264\u306e\u30d9\u30c3\u30c9\u30b5\u30a4\u30ba\u304c\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u3092\u9632\u3050\u305f\u3081\u306b\u5341\u5206\u306a\u4fdd\u6301\u529b\u3092\u63d0\u4f9b\u3067\u304d\u308b\u304b\u306a\u3069\u3092\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>96\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\uff1a <\/strong>96\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u306f\u3001\u5927\u91cf\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u8fc5\u901f\u306b\u51e6\u7406\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u30e9\u30dc\u3067\u4f7f\u7528\u3055\u308c\u308b\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3067\u3059\u3002\u5404\u30a6\u30a7\u30eb\u306f\u72ec\u7acb\u3057\u305f\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u3088\u3046\u306b\u6a5f\u80fd\u3057\u3001\u540c\u6642\u306b\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u51e6\u7406\u3067\u304d\u307e\u3059\u300296\u30a6\u30a7\u30eb\u30d7\u30ec\u30fc\u30c8\u306e\u5229\u7528\u306f\u3001\u7279\u5b9a\u306e\u88c5\u7f6e\uff08\u4f8b\u3048\u3070\u3001\u81ea\u52d5\u30d4\u30da\u30c3\u30bf\u30fc\u3084\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\uff09\u3068\u7d44\u307f\u5408\u308f\u305b\u3066\u884c\u3046\u3053\u3068\u304c\u591a\u304f\u3001\u3053\u308c\u3089\u306e\u88c5\u7f6e\u3068\u4e92\u63db\u6027\u306e\u3042\u308b\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u3082\u91cd\u8981\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong>\u5206\u6563\u578bSPE\uff08dSPE\uff09\uff1a <\/strong>QuEChERS\u6cd5\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u62bd\u51fa\u7269\u306e\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u306b\u7279\u5316\u3057\u305f\u624b\u6cd5\u3067\u3059\u3002dSPE\u3067\u306f\u3001SPE\u5145\u586b\u5264\u3092\u30b5\u30f3\u30d7\u30eb\u62bd\u51fa\u7269\u306b\u76f4\u63a5\u52a0\u3048\u3001\u632f\u3068\u3046\u5f8c\u5f8c\u306b\u9060\u5fc3\u5206\u96e2\u3092\u884c\u3044\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u8fc5\u901f\u306b\u51e6\u7406\u3057\u307e\u3059\u3002\u3053\u306e\u65b9\u6cd5\u306f\u7279\u306b\u98df\u54c1\u5b89\u5168\u5206\u91ce\u3067\u5e83\u304f\u5229\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u8907\u96d1\u306a\u30b5\u30f3\u30d7\u30eb\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304b\u3089\u306e\u8fc5\u901f\u306a\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u304c\u53ef\u80fd\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong>\u30a4\u30f3\u30e9\u30a4\u30f3\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406 \uff08ILSP\uff09\uff1a <\/strong>LC-MS\u304a\u3088\u3073LC-MS\/MS\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u306b\u9069\u3057\u305f\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3067\u3001\u88c5\u7f6e\u306b\u6ce8\u5165\u3055\u308c\u305f\u30b5\u30f3\u30d7\u30eb\u304c\u6700\u521d\u306bILSP\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u901a\u904e\u3057\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u5206\u96e2\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u30c7\u30a3\u30b9\u30af\uff1a<\/strong> \u4e00\u90e8\u306e\u7279\u6b8a\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u4f7f\u7528\u3055\u308c\u308b\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u3067\u3059\u3002\u901a\u5e38\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3088\u308a\u3082\u9ad8\u3044\u6d41\u91cf\u3067\u5927\u91cf\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u51e6\u7406\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u30d0\u30eb\u30af\uff1a<\/strong> \u72ec\u81ea\u306e\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u88c5\u7f6e\u3092\u5e0c\u671b\u3059\u308b\u9867\u5ba2\u5411\u3051\u306b\u30d0\u30eb\u30af\u3067\u8ca9\u58f2\u3055\u308c\u308b\u5145\u586b\u5264\u3067\u3059\u3002\u4e00\u822c\u7684\u306aSPE\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3067\u306f\u3042\u307e\u308a\u4f7f\u7528\u3055\u308c\u307e\u305b\u3093\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306b\u52a0\u3048\u3001\u30b5\u30f3\u30d7\u30eb\u3068\u306e\u9069\u5408\u6027\u3084SPE\u88fd\u54c1\u81ea\u4f53\u304b\u3089\u306e\u4e0d\u8981\u306a\u5e72\u6e09\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u6750\u8cea\u3082\u91cd\u8981\u3067\u3059\u3002\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3067\u306f\u5341\u5206\u306a\u8010\u6027\u304c\u5f97\u3089\u308c\u306a\u3044\u5834\u5408\u306b\u306f\u3001\u8010\u6027\u306e\u3042\u308b\u4e0d\u6d3b\u6027\u30ac\u30e9\u30b9\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u307e\u305f\u3001PFAS\u3092\u4f4e\u30ec\u30d9\u30eb\u6fc3\u5ea6\u3067\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u5834\u5408\u3001\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3092\u907f\u3051\u308b\u305f\u3081\u306b\u5225\u306e\u6750\u8cea\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6ce8\u76ee\u3059\u3079\u304dSPE\u306e\u7279\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u7279\u6027\u3092\u7406\u89e3\u3057\u3001\u6700\u9069\u306a\u5145\u586b\u5264\u3068\u6eb6\u5a92\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u7279\u306b\u3001\u6975\u6027\u3001\u30a4\u30aa\u30f3\u4ea4\u63db\u3001\u307e\u305f\u306f\u305d\u306e\u4e21\u65b9\u3092\u6d3b\u7528\u3057\u305f\u30df\u30c3\u30af\u30b9\u30e2\u30fc\u30c9\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u8003\u616e\u3057\u305f\u9078\u629e\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u3053\u308c\u306b\u52a0\u3048\u3066\u3001\u88fd\u54c1\u8aac\u660e\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u5145\u586b\u5264\u306e\u7279\u6027\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001SPE\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u3055\u3089\u306b\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u306b\u3001SPE\u306e\u7d50\u679c\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u4e3b\u8981\u306a\u7279\u6027\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5145\u586b\u5264\u306e\u7279\u6027<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u7c92\u5b50\u7279\u6027\uff1a<\/strong> \u540c\u4e00\u88fd\u54c1\u5185\u3067\u7c92\u5b50\u30b5\u30a4\u30ba\u3084\u7d30\u5b54\u30b5\u30a4\u30ba\uff0f\u5bb9\u7a4d\u306f\u6bd4\u8f03\u7684\u4e00\u5b9a\u3067\u3059\u304c\u3001\u30d9\u30f3\u30c0\u30fc\u9593\u3067\u6bd4\u8f03\u3059\u308b\u3068\u9055\u3044\u304c\u898b\u3089\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u30bf\u30fc\u30b2\u30c3\u30c8\u5206\u6790\u6210\u5206\u304c\u7c92\u5b50\u306e\u7d30\u5b54\u306b\u5165\u308b\u306e\u306b\u5341\u5206\u306a\u30b5\u30a4\u30ba\u3067\u3042\u308b\u5834\u5408\u3001\u7c92\u5b50\u30b5\u30a4\u30ba\u3084\u7d30\u5b54\u30b5\u30a4\u30ba\/\u5bb9\u7a4d\u306f\u8868\u9762\u7a4d\u3068\u70ad\u7d20\u542b\u6709\u91cf\u306b\u5927\u304d\u304f\u95a2\u4fc2\u3057\u307e\u3059\u3002\n<ul class=\"wp-block-list\">\n<li>\u6ce8\uff1a\u7c92\u5b50\u5f84\u306f\u3001\u76f4\u63a5\u6e2c\u5b9a\u3059\u308b\u65b9\u6cd5\u3068\u300c\u30e1\u30c3\u30b7\u30e5\u30b5\u30a4\u30ba\u300d\u3068\u3057\u3066\u6e2c\u5b9a\u3059\u308b\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u30e1\u30c3\u30b7\u30e5\u30b5\u30a4\u30ba\u3068\u306f\u30011\u30a4\u30f3\u30c1\u3042\u305f\u308a\u306e\u7db2\u76ee\u306e\u6570\u3092\u8868\u3059\u6307\u6a19\u3067\u3059\u3002\u6570\u5b57\u304c\u5927\u304d\u3044\u307b\u3069\u7db2\u76ee\u304c\u7d30\u304b\u304f\u306a\u308a\u3001\u5c0f\u3055\u306a\u7c92\u5b50\u3092\u3075\u308b\u3044\u306b\u304b\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u3001\u30e1\u30c3\u30b7\u30e5\u30b5\u30a4\u30ba\u304c\u5927\u304d\u3044\u307b\u3069\u7c92\u5b50\u306e\u30b5\u30a4\u30ba\u306f\u5c0f\u3055\u304f\u306a\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><strong>\u8868\u9762\u7a4d\uff08m<sup>2<\/sup>\/g\u3067\u8868\u793a\uff09\uff1a<\/strong> \u7c92\u5b50\u30b5\u30a4\u30ba\u3068\u7c92\u5b50\u306e\u7d30\u5b54\u306e\u30b5\u30a4\u30ba\u304a\u3088\u3073\u4f53\u7a4d\u306b\u3088\u3063\u3066\u5b9a\u7fa9\u3055\u308c\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u5145\u586b\u5264\u3092\u901a\u904e\u3059\u308b\u969b\u306b\u76f8\u4e92\u4f5c\u7528\u53ef\u80fd\u306a\u8868\u9762\u7a4d\u3092\u8868\u3057\u307e\u3059\u3002\u8868\u9762\u7a4d\u304c\u5927\u304d\u3044\u307b\u3069\u3001\u4fdd\u6301\u306f\u5f37\u304f\u306a\u308a\u307e\u3059\u3002\u7c92\u5b50\u5f84\u3084\u7d30\u5b54\u5f84\u304c\u5c0f\u3055\u3044\u5145\u586b\u5264\u306f\u3001\u7c92\u5b50\u5f84\u3084\u7d30\u5b54\u5f84\u304c\u5927\u304d\u3044\u5145\u586b\u5264\u3088\u308a\u3082\u5358\u4f4d\u9762\u7a4d\uff08g\uff09\u3042\u305f\u308a\u306e\u8868\u9762\u7a4d\u304c\u5927\u304d\u304f\u306a\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u70ad\u7d20\u542b\u6709\u91cf\uff08\u5145\u586b\u5264\u7dcf\u8cea\u91cf\u306b\u5bfe\u3059\u308b\u5272\u5408\u3067\u8868\u793a\uff09\uff1a<\/strong> SPE\u5145\u586b\u5264\u306e\u8868\u9762\u306b\u5316\u5b66\u7269\u8cea\u304c\u7d50\u5408\u3057\u3066\u3044\u308b\u5834\u5408\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u30b7\u30ea\u30ab\u7c92\u5b50\u306e\u8868\u9762\u306bC18\u30ea\u30ac\u30f3\u30c9\u304c\u7d50\u5408\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u70ad\u7d20\u542b\u6709\u91cf\u306f\u3001\u7d50\u5408\u30ea\u30ac\u30f3\u30c9\u306e\u8868\u9762\u88ab\u8986\u7387\u3092\u793a\u3057\u3001\u5145\u586b\u5264\u306e\u4fdd\u6301\u529b\u306e\u6307\u6a19\u3068\u306a\u308a\u307e\u3059\u3002\u70ad\u7d20\u542b\u6709\u91cf\u304c\u9ad8\u3044\u5145\u586b\u5264\u306f\u3001\u758e\u6c34\u6027\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u5358\u4f4d\u91cd\u91cf\u3042\u305f\u308a\u306e\u4fdd\u6301\u529b\u304c\u9ad8\u3044\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u30a4\u30aa\u30f3\u4ea4\u63db\u5bb9\u91cf\uff08mEq\/g\u3067\u8868\u793a\uff09\uff1a<\/strong>\u5145\u586b\u5264\u304c\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u30a4\u30aa\u30f3\u3092\u88dc\u8db3\u3059\u308b\u80fd\u529b\u3092\u793a\u3059\u6307\u6a19\u3067\u3001\u5bfe\u30a4\u30aa\u30f3\u3092\u5f62\u6210\u3067\u304d\u308b\u90e8\u4f4d\u306e\u7dcf\u91cf\u3092\u793a\u3057\u307e\u3059\u3002\u30df\u30ea\u5f53\u91cf\/\u30b0\u30e9\u30e0\uff08mEq\/g\uff09\u306f\u3001\u5145\u586b\u5264\u304c\u3069\u308c\u3060\u3051\u306e\u91cf\u306e\u96fb\u8377\u3092\u6301\u3064\u30a4\u30aa\u30f3\u3092\u4ea4\u63db\u3067\u304d\u308b\u304b\u3092\u793a\u3057\u3001\u3053\u306e\u5024\u304c\u5927\u304d\u3044\u307b\u3069\u30a4\u30aa\u30f3\u4fdd\u6301\u80fd\u529b\u304c\u9ad8\u3044\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u7279\u6027<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u30db\u30fc\u30eb\u30c9\u30a2\u30c3\u30d7\u30dc\u30ea\u30e5\u30fc\u30e0\uff1a<\/strong>SPE\u306e\u30db\u30fc\u30eb\u30c9\u30a2\u30c3\u30d7\u30dc\u30ea\u30e5\u30fc\u30e0\u306f\u3001\u4fdd\u6301\u3055\u308c\u306a\u3044\u7269\u8cea\u3092\u6eb6\u51fa\u3055\u305b\u308b\u305f\u3081\u306b\u5fc5\u8981\u306a\u6eb6\u5a92\u91cf\u3092\u6307\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u5206\u6790\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u300c\u30db\u30fc\u30eb\u30c9\u30a2\u30c3\u30d7\u30bf\u30a4\u30e0\u300d\u3084\u300c\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u300d\u3068\u540c\u69d8\u306e\u6982\u5ff5\u3067\u3059\u3002\u30db\u30fc\u30eb\u30c9\u30a2\u30c3\u30d7\u30dc\u30ea\u30e5\u30fc\u30e0\u304c\u9069\u5207\u3067\u306a\u3044\u3068\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u56de\u53ce\u7387\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u305f\u3081\u3001\u78ba\u8a8d\u304c\u5fc5\u8981\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong>\u30ed\u30fc\u30c9\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\uff1a<\/strong> SPE\u5145\u586b\u5264\u304c\u4fdd\u6301\u3067\u304d\u308b\u7269\u8cea\u306e\u91cf\u306e\u63a8\u5b9a\u5024\u3067\u3042\u308a\u3001\u901a\u5e38\u3001\u5145\u586b\u5264\u30d9\u30c3\u30c9\u306e\u91cd\u91cf\u306e\u7d0410\uff05\u3068\u3057\u3066\u793a\u3055\u308c\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u3053\u306e\u63a8\u5b9a\u5024\u306f\u3001\u975e\u5e38\u306b\u5f31\u3044\u6eb6\u5a92\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306e\u4fdd\u6301\u3092\u524d\u63d0\u3068\u3057\u3066\u3044\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u306e\u6027\u8cea\u3001\u6eb6\u5a92\u3001\u6d41\u901f\u306a\u3069\u3001\u591a\u304f\u306e\u8981\u7d20\u304c\u6700\u7d42\u7684\u306a\u30ed\u30fc\u30c9\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u305f\u3081\u3001\u5b9f\u969b\u306e\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u306f\u7570\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u6700\u9069\u306a\u30ed\u30fc\u30c9\u30ad\u30e3\u30d1\u30b7\u30c6\u30a3\u3092\u77e5\u308b\u305f\u3081\u306b\u306f\u3001\u5b9f\u9a13\u7684\u306a\u78ba\u8a8d\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">SPE\u88fd\u54c1\u306b\u4ed8\u5c5e\u306e\u8aac\u660e\u66f8\u3092\u30ac\u30a4\u30c9\u3068\u3057\u3066\u4f7f\u7528<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3055\u307e\u3056\u307e\u306a\u7a2e\u985e\u306e\u30b5\u30f3\u30d7\u30eb\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3001\u304a\u3088\u3073\u5206\u6790\u65b9\u6cd5\u304c\u5b58\u5728\u3059\u308b\u305f\u3081\u3001\u3059\u3079\u3066\u306e\u30b1\u30fc\u30b9\u306b\u9069\u7528\u3067\u304d\u308b\u5171\u901a\u306eSPE\u30e1\u30bd\u30c3\u30c9\u306f\u5b58\u5728\u3057\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u7406\u89e3\u3057\u3001\u305d\u308c\u306b\u9069\u3057\u305fSPE\u88fd\u54c1\u3092\u9078\u629e\u3059\u308c\u3070\u3001\u305d\u306e\u88fd\u54c1\u306e\u8aac\u660e\u66f8\u304c\u6709\u52b9\u306a\u30ac\u30a4\u30c9\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SPE\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u304a\u3051\u308b\u5b9f\u9a13\u306e\u4fa1\u5024<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u30e1\u30bd\u30c3\u30c9\u3092\u958b\u767a\u3059\u308b\u969b\u306b\u306f\u3001\u3044\u304f\u3064\u304b\u306e\u5b9f\u9a13\u3092\u884c\u3046\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001SPE\u30d7\u30ed\u30bb\u30b9\u306e\u5404\u30b9\u30c6\u30c3\u30d7\u3067\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u671b\u307e\u3057\u3044\u6319\u52d5\u3092\u793a\u3057\u3066\u3044\u308b\u304b\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u5b9f\u9a13\u3092\u901a\u3058\u3066\u3001\u6b21\u306e\u70b9\u3092\u78ba\u8a8d\u30fb\u6539\u5584\u3057\u306a\u304c\u3089\u9032\u3081\u308b\u3068\u3001\u3088\u308a\u826f\u3044SPE\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5145\u586b\u5264\u3068\u6eb6\u5a92\u306e\u9078\u629e\u304c\u9069\u5207\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3059\u308b\u3002<\/li>\n\n\n\n<li>\u30e1\u30bd\u30c3\u30c9\u306e\u76ee\u7684\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u5fc5\u8981\u6700\u5c0f\u9650\u306e\u5145\u586b\u5264\u91cf\u3084\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u30b5\u30a4\u30ba\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u304b\u78ba\u8a8d\u3059\u308b\u3002<\/li>\n\n\n\n<li>\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u3084\u6d17\u6d44\u30b9\u30c6\u30c3\u30d7\u3067\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u306b\u3088\u3063\u3066\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u5931\u308f\u308c\u3066\u3044\u306a\u3044\u304b\u78ba\u8a8d\u3059\u308b\u3002<\/li>\n\n\n\n<li>\u9078\u629e\u3057\u305f\u6761\u4ef6\u4e0b\u3067\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u52b9\u679c\u7684\u306b\u6eb6\u51fa\u3055\u308c\u3066\u3044\u308b\u304b\u3001\u5145\u586b\u5264\u306b\u6b8b\u7559\u3057\u3066\u3044\u306a\u3044\u304b\u3092\u78ba\u8a8d\u3059\u308b\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u901a\u5e38\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u4e2d\u306b\u300c\u30de\u30b9\u30d0\u30e9\u30f3\u30b9\u300d\u3068\u300c\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u300d\u306b\u95a2\u3059\u308b\u8a66\u9a13\u306e\u5b9f\u65bd\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u8a66\u9a13\u306f\u3001\u5206\u6790\u5bfe\u8c61\u30b5\u30f3\u30d7\u30eb\u306b\u5bfe\u3057\u3066\u30d7\u30ed\u30bb\u30b9\u304c\u9069\u5207\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u6709\u52b9\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u30de\u30b9\u30d0\u30e9\u30f3\u30b9\uff1a<\/strong>\u3053\u306e\u8a66\u9a13\u3067\u306f\u3001SPE\u30d7\u30ed\u30bb\u30b9\u306e\u5404\u30b9\u30c6\u30c3\u30d7\u3067SPE\u88fd\u54c1\u304b\u3089\u6eb6\u51fa\u3059\u308b\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u3092\u53ce\u96c6\u3057\u3001SPE\u30d7\u30ed\u30bb\u30b9\u5168\u4f53\u306b\u304a\u3051\u308b\u5206\u6790\u6210\u5206\u306e\u6319\u52d5\u3092\u8a55\u4fa1\u3057\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u7d44\u6210\u306b\u8fd1\u3044\u8a66\u6599\u3092\u6e96\u5099\u3057\u3001\u3053\u306e\u5b9f\u9a13\u3092\u884c\u3046\u3053\u3068\u3067\u3001\u4fdd\u6301\u3057\u305f\u3044\u6210\u5206\u304c\u304d\u3061\u3093\u3068\u5145\u586b\u5264\u306b\u4fdd\u6301\u3055\u308c\u3001\u6eb6\u51fa\u3055\u305b\u305f\u3044\u6210\u5206\u304c\u5404\u30b9\u30c6\u30c3\u30d7\u3067\u6b63\u3057\u304f\u6eb6\u51fa\u3055\u308c\u3066\u3044\u308b\u304b\u3092\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\uff1a<\/strong> \u3053\u306e\u8a66\u9a13\u3067\u306f\u3001\u958b\u767a\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u306b\u5408\u308f\u305b\u305f\u30b5\u30f3\u30d7\u30eb\u4f53\u7a4d\u3092\u57fa\u6e96\u306b\u3001\u3055\u307e\u3056\u307e\u306a\u4f53\u7a4d\u306e\u30b5\u30f3\u30d7\u30eb\uff08\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u6fc3\u5ea6\u306f\u7d71\u4e00\uff09\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002\u7570\u306a\u308b\u91cf\u306e\u30b5\u30f3\u30d7\u30eb\u3092SPE\u306b\u30ed\u30fc\u30c9\u3057\u3001\u524d\u51e6\u7406\u30d7\u30ed\u30bb\u30b9\u3092\u5b9f\u884c\u3057\u3066\u6eb6\u51fa\u7269\u3092\u53ce\u96c6\u3057\u3001\u5206\u6790\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u30ed\u30fc\u30c9\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u91cf\u3068\u6fc3\u5ea6\u306b\u57fa\u3065\u3044\u3066\u56de\u53ce\u7387\u3092\u8a08\u7b97\u3057\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u306e\u30ed\u30fc\u30c9\u91cf\u3068\u56de\u53ce\u7387\u3092\u30d7\u30ed\u30c3\u30c8\u3059\u308b\u3053\u3068\u3067\u3001\u3069\u306e\u30b5\u30f3\u30d7\u30eb\u30ed\u30fc\u30c9\u91cf\u3067\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u304c\u8d77\u3053\u308b\u304b\u3092\u628a\u63e1\u3067\u304d\u307e\u3059\u3002\u4fdd\u6301\u52b9\u7387\u304c\u30b5\u30f3\u30d7\u30eb\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u901f\u5ea6\u306b\u3088\u3063\u3066\u5909\u308f\u3089\u306a\u3044\u3088\u3046\u3001\u4e00\u5b9a\u306e\u901f\u5ea6\u3067\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u3092\u884c\u3046\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">SPE\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u306b\u304a\u56f0\u308a\u3067\u3059\u304b\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u30e1\u30bd\u30c3\u30c9\u306e\u78ba\u7acb\u306b\u306f\u591a\u304f\u306e\u9078\u629e\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u304c\u3001\u3053\u306e\u8a18\u4e8b\u3067\u306f\u305d\u306e\u306f\u3058\u3081\u306e\u4e00\u6b69\u3092\u7d39\u4ecb\u3057\u307e\u3057\u305f\u3002\u56fa\u76f8\u62bd\u51fa\u306f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u4e00\u7a2e\u3068\u8003\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002SPE\u30e1\u30bd\u30c3\u30c9\u306e\u958b\u767a\u3092\u9032\u3081\u308b\u306b\u3064\u308c\u3066\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3001\u304a\u3088\u3073\u5206\u6790\u306b\u7279\u6709\u306e\u7591\u554f\u304c\u751f\u3058\u308b\u3053\u3068\u304c\u3042\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u5c02\u9580\u5bb6\u3067\u3042\u308bRestek\u304c\u3001\u3044\u3064\u3067\u3082\u304a\u624b\u4f1d\u3044\u3057\u307e\u3059\u306e\u3067\u3001\u3054\u4e0d\u660e\u70b9\u3084\u304a\u56f0\u308a\u3054\u3068\u304c\u3042\u308c\u3070\u3054\u9023\u7d61\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e9\u30dc\u3067\u306eSPE\u4f7f\u7528\u306b\u95a2\u3059\u308b\u3054\u8cea\u554f\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/contact-us\" target=\"_blank\" rel=\"noopener\">Restek\u62c5\u5f53\u8005<\/a>\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u306f\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3044\u3066\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3092\u884c\u3046\u305f\u3081\u306e\u91cd\u8981\u306a\u6280\u8853\u3067\u3059\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001SPE\u306e\u57fa\u790e\u304b\u3089\u5fdc\u7528\u307e\u3067\u3092\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac\u3057\u3001\u521d\u5fc3\u8005\u304b\u3089\u4e0a\u7d1a\u8005\u307e\u3067\u5e45\u5e83\u304f\u30ab\u30d0\u30fc\u3057\u3066\u3044\u307e\u3059\u3002SPE\u306e\u539f\u7406\u3001\u6226\u7565\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306b\u3064\u3044\u3066\u5b66\u3073\u3001\u5206\u6790\u306e\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u307e\u3057\u3087\u3046\u3002<\/p>\n","protected":false},"author":11,"featured_media":7141,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2402,2582,2555],"resource-technique":[2346],"ppma_author":[2814,414],"class_list":["post-45334","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","product-library-spe-sle","product-library-spe-sle-ja","product-library-sample-preparation-products-ja","resource-technique-solid-phase-extraction-spe-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"product-library":[{"value":2402,"label":"SPE &amp; SLE"},{"value":2582,"label":"SPE\uff5cSLE"},{"value":2555,"label":"\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406"}],"resource-technique":[{"value":2346,"label":"\u56fa\u76f8\u62bd\u51fa (SPE)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAR3685-1024x550.jpg",1024,550,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":511,"filter":"raw","cat_ID":789,"category_count":511,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45334","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45334"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45334\/revisions"}],"predecessor-version":[{"id":81018,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45334\/revisions\/81018"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/7141"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45334"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45334"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45334"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45334"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45334"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45334"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45334"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45334"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45334"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}