{"id":45338,"date":"2025-10-08T17:55:39","date_gmt":"2025-10-08T17:55:39","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/c1-c10-pfas-analysis-in-human-plasma-and-serum-japan\/"},"modified":"2026-04-28T20:11:21","modified_gmt":"2026-04-28T20:11:21","slug":"c1-c10-pfas-analysis-in-human-plasma-and-serum-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/cfan4273-ja\/c1-c10-pfas-analysis-in-human-plasma-and-serum-japan","title":{"rendered":"\u8d85\u77ed\u9396PFAS\u306e\u8840\u6f3f\u304a\u3088\u3073\u8840\u6e05\u4e2d\u306e\u9ad8\u611f\u5ea6\u5206\u6790"},"content":{"rendered":"\n<div style=\"height:10px\" aria-hidden=\"true\" id=\"top-of-page\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-table-of-content-nav.kb-table-of-content-id45338_a508d8-33 .kb-table-of-content-wrap{padding-top:var(--global-kb-spacing-sm, 1.5rem);padding-right:var(--global-kb-spacing-sm, 1.5rem);padding-bottom:var(--global-kb-spacing-sm, 1.5rem);padding-left:var(--global-kb-spacing-sm, 1.5rem);}.kb-table-of-content-nav.kb-table-of-content-id45338_a508d8-33 .kb-table-of-contents-title-wrap{padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.kb-table-of-content-nav.kb-table-of-content-id45338_a508d8-33 .kb-table-of-contents-title{font-weight:regular;font-style:normal;}.kb-table-of-content-nav.kb-table-of-content-id45338_a508d8-33 .kb-table-of-content-wrap .kb-table-of-content-list{font-weight:regular;font-style:normal;margin-top:var(--global-kb-spacing-sm, 1.5rem);margin-right:0px;margin-bottom:0px;margin-left:0px;}<\/style>\n\n\n<h2 class=\"wp-block-heading\" id=\"1-\u30a4\u30f3\u30c8\u30ed\u30c0\u30af\u30b7\u30e7\u30f3\">1. \u30a4\u30f3\u30c8\u30ed\u30c0\u30af\u30b7\u30e7\u30f3<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff08PFAS\uff09\u306f\u3001\u74b0\u5883\u4e2d\u306b\u5e83\u304f\u5b58\u5728\u3057\u3001\u4eba\u4f53\u3078\u306e\u5f71\u97ff\u304c\u61f8\u5ff5\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7279\u306bC1\u301cC3\u306e\u8d85\u77ed\u9396PFAS\u306f\u305d\u306e\u9ad8\u3044\u6975\u6027\u306b\u3088\u308a\u5f93\u6765\u306e\u5206\u6790\u624b\u6cd5\u3067\u306f\u6e2c\u5b9a\u304c\u96e3\u3057\u304f\u3001\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u304c\u5fc5\u8981\u3067\u3059(PFAS\u95a2\u9023\u8a18\u4e8b\u306f<a href=\"https:\/\/www.restek.com\/PFAS-JP\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/PFAS-JP<\/a>\u304b\u3089\u78ba\u8a8d\u3067\u304d\u307e\u3059\uff09\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001\u30d2\u30c8\u8840\u6f3f\u304a\u3088\u3073\u8840\u6e05\u4e2d\u306e\u8d85\u77ed\u9396PFAS\u3092\u5bfe\u8c61\u3068\u3057\u305fLC-MS\/MS\u306b\u3088\u308b\u9ad8\u611f\u5ea6\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"2-\u8d85\u77ed\u9396pfas\u3068\u306f\uff1f\">2. \u8d85\u77ed\u9396PFAS\u3068\u306f\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8d85\u77ed\u9396PFAS\uff08C1\u301cC3\uff09\u306f\u3001\u9577\u9396PFAS\u3068\u6bd4\u8f03\u3057\u3066\u5206\u5b50\u91cf\u304c\u5c0f\u3055\u304f\u3001\u6975\u6027\u304c\u9ad8\u3044\u305f\u3081\u3001\u9006\u76f8\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u306e\u5206\u96e2\u304c\u96e3\u3057\u3044\u5316\u5408\u7269\u3067\u3059\u3002\u74b0\u5883\u4e2d\u3067\u306e\u504f\u5728\u3084\u4eba\u4f53\u3078\u306e\u66b4\u9732\u304c\u5897\u52a0\u3059\u308b\u4e2d\u3001\u9069\u5207\u306a\u6e2c\u5b9a\u65b9\u6cd5\u306e\u958b\u767a\u304c\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> C1\u304b\u3089C3 PFAS\u306e\u69cb\u9020<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"689\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-1024x689.jpg\" alt=\"\" class=\"wp-image-19125\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-1024x689.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-300x202.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-768x517.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01-1536x1033.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-article-CFAN4273-01.jpg 1800w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"3-pfas\u5206\u6790\u306e\u8ab2\u984c\u3068\u89e3\u6c7a\u7b56\">3. PFAS\u5206\u6790\u306e\u8ab2\u984c\u3068\u89e3\u6c7a\u7b56<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f93\u6765\u306e\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u306f\u3001\u8d85\u77ed\u9396PFAS\u306e\u4fdd\u6301\u304c\u96e3\u3057\u3044\u3068\u3044\u3046\u8ab2\u984c\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u305d\u3053\u3067\u3001\u6975\u6027\u57fa\u5185\u5305\u578bUltra IBD\u30ab\u30e9\u30e0\uff08100 mm \u00d7 2.1 mm, 3 \u00b5m, (<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/9175312\" target=\"_blank\" rel=\"noopener\">cat.# 9175312<\/a>))\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001C1\u301cC10\u306ePFAS\u3092\u9ad8\u611f\u5ea6\u3067\u5206\u96e2\u30fb\u5b9a\u91cf\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u3001\u52b9\u7387\u7684\u306a\u4e00\u6589\u5206\u6790\u304c\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"4-lc-ms-ms\u3092\u7528\u3044\u305f\u8d85\u77ed\u9396pfas\u5206\u6790\u306e\u7279\u5fb4\">4. LC-MS\/MS\u3092\u7528\u3044\u305f\u8d85\u77ed\u9396PFAS\u5206\u6790\u306e\u7279\u5fb4<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u9ad8\u611f\u5ea6\u306aLC-MS\/MS\u6e2c\u5b9a: \u6975\u6027\u57fa\u5185\u5305\u578b\u30ab\u30e9\u30e0\u306b\u3088\u308a\u8d85\u77ed\u9396PFAS\u306e\u4fdd\u6301\u3092\u6539\u5584\u3057\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u5e72\u6e09\u3092\u4f4e\u6e1b\u3002<\/li>\n\n\n\n<li>PFAS\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0(<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/27854\" target=\"_blank\" rel=\"noopener\">cat.# 27854<\/a>): \u6e2c\u5b9a\u306e\u6b63\u78ba\u6027\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u3001\u30b7\u30b9\u30c6\u30e0\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3092\u9632\u6b62\u3002<\/li>\n\n\n\n<li>\u5b89\u5b9a\u540c\u4f4d\u4f53\u6a19\u8b58\u3092\u7528\u3044\u305f\u5185\u90e8\u6a19\u6e96: \u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306e\u5f71\u97ff\u3092\u88dc\u6b63\u3059\u308b\u3053\u3068\u3067\u3001\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u53d6\u5f97\u304c\u53ef\u80fd\u3002<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> 10 ppb PFAS\u6a19\u6e96\u8a66\u6599\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0812.png\" alt=\"Simultaneous Analysis of C1 to C10 PFAS and Alternative Compounds on Ultra IBD\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0812<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>30734<\/li><li>9175312<\/li><li>27854<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>PFAS<\/li><li>PFAS Biomonitoring<\/li><li>Ultrashort-Chain<\/li><li>pfas-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0812.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"5-nist\u6a19\u6e96\u53c2\u7167\u7269\u8cea\u306b\u3088\u308b\u4fe1\u983c\u6027\u306e\u78ba\u4fdd\">5. NIST\u6a19\u6e96\u53c2\u7167\u7269\u8cea\u306b\u3088\u308b\u4fe1\u983c\u6027\u306e\u78ba\u4fdd<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">NIST\u6a19\u6e96\u53c2\u7167\u7269\u8cea\u3067\u3042\u308b\u8840\u6f3f\uff08SRM 1950\uff09\u304a\u3088\u3073\u8840\u6e05\uff08SRM 1957\uff09\u306f\u3001\u65e2\u77e5\u306ePFAS\u6fc3\u5ea6\u3092\u542b\u3093\u3067\u304a\u308a\u3001\u6e2c\u5b9a\u7cbe\u5ea6\u306e\u8a55\u4fa1\u57fa\u6e96\u3068\u3057\u3066\u4f7f\u7528\u3055\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u518d\u73fe\u6027\u3068\u4fe1\u983c\u6027\u304c\u78ba\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"6-\u30d0\u30a4\u30aa\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3067\u306e\u8d85\u77ed\u9396pfas\u6e2c\u5b9a\u306e\u91cd\u8981\u6027\">6. \u30d0\u30a4\u30aa\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3067\u306e\u8d85\u77ed\u9396PFAS\u6e2c\u5b9a\u306e\u91cd\u8981\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d2\u30c8\u8840\u6f3f\u304a\u3088\u3073\u8840\u6e05\u4e2d\u306e\u8d85\u77ed\u9396PFAS\u3092\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3059\u308b\u3053\u3068\u306f\u3001\u5065\u5eb7\u30ea\u30b9\u30af\u8a55\u4fa1\u3084\u898f\u5236\u7b56\u5b9a\u306b\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u672c\u5206\u6790\u624b\u6cd5\u306f\u3001\u6b63\u78ba\u306a\u6e2c\u5b9a\u30c7\u30fc\u30bf\u3092\u63d0\u4f9b\u3059\u308b\u305f\u3081\u3001\u8d85\u77ed\u9396PFAS\u306e\u5065\u5eb7\u5f71\u97ff\u306b\u95a2\u3059\u308b\u7406\u89e3\u3092\u6df1\u3081\u308b\u306e\u306b\u5f79\u7acb\u3061\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"7-\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u8cc7\u6599\uff1alc-ms-ms\u5206\u6790\u306b\u95a2\u3059\u308b\u30b5\u30a4\u30a8\u30f3\u30b9\u30ec\u30dd\u30fc\u30c8\">7. \u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u8cc7\u6599\uff1aLC-MS\/MS\u5206\u6790\u306b\u95a2\u3059\u308b\u30b5\u30a4\u30a8\u30f3\u30b9\u30ec\u30dd\u30fc\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8a73\u7d30\u306a\u5b9f\u9a13\u624b\u6cd5\u3084\u30c7\u30fc\u30bf\u306b\u3064\u3044\u3066\u306f\u3001\u30b5\u30a4\u30a8\u30f3\u30b9\u30ec\u30dd\u30fc\u30c8\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3057\u3066\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<br><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/CFAN4273-JP.pdf\">\u30b5\u30a4\u30a8\u30f3\u30b9\u30ec\u30dd\u30fc\u30c8\u306e\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306f\u3053\u3061\u3089<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top-of-page\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9175312\">                                \u30ab\u30bf\u30ed\u30b0No. 9175312                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ultra IBD, 3 \u00b5m, 100 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9175312\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9175312-T\">                                \u30ab\u30bf\u30ed\u30b0No. 9175312-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Ultra IBD Inert, 3 \u00b5m, 100 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9175312-T\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                \u30ab\u30bf\u30ed\u30b0No. 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS\u5206\u6790\uff5c\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0, 5 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24626\">                                \u30ab\u30bf\u30ed\u30b0No. 24626                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Big Mouth Step Screw-Thread Vials with Grad Marking Spot, 2.0 mL, 12 x 32 mm, 10 mm\/425 Thread (Vial Only), Clear, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24626\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30734\">                                \u30ab\u30bf\u30ed\u30b0No. 30734                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS\uff08\u6709\u6a5f\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff09\u5206\u6790\u7528\u6a19\u6e96\u54c1\uff5cPFAS 28\u6210\u5206\u6df7\u5408 Calibration Standard, 1 \u00b5g\/mL<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/30734\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24518\">                                \u30ab\u30bf\u30ed\u30b0No. 24518                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial Inserts, Polypropylene, Big Mouth w\/Bottom Spring, 250 \u00b5L, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24518\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25097\">                                \u30ab\u30bf\u30ed\u30b0No. 25097                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Survival Kit for HPLC, Stainless Steel<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/25097\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u8d85\u77ed\u9396PFAS\u306e\u6b63\u78ba\u306a\u6e2c\u5b9a\u3092\u53ef\u80fd\u306b\u3059\u308b\u9ad8\u611f\u5ea6LC-MS\/MS\u5206\u6790\u6cd5\u3092\u7d39\u4ecb\u3002NIST\u6a19\u6e96\u53c2\u7167\u7269\u8cea\u3092\u4f7f\u7528\u3057\u305f\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30e1\u30bd\u30c3\u30c9\u3067\u3001\u30d2\u30c8\u8840\u6f3f\u304a\u3088\u3073\u8840\u6e05\u4e2d\u306ePFAS\u6fc3\u5ea6\u3092\u6b63\u78ba\u306b\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3002<\/p>\n","protected":false},"author":46,"featured_media":6403,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[785],"tags":[2760],"industries-application":[2288,2271,2266,2269],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2365,2343],"ppma_author":[578,702],"class_list":["post-45338","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-environmental-ja","industries-application-clinical-ja","industries-application-clinical-toxicology-ja","resource-technique-ms-ms-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2266,"label":"\u81e8\u5e8a"},{"value":2269,"label":"\u81e8\u5e8a\u6bd2\u6027\u5b66"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFAN4273-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Shun-Hsin Liang, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/shun-hsin-liang-phd\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":86,"filter":"raw","cat_ID":785,"category_count":86,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":578,"user_id":46,"is_guest":0,"slug":"shun-hsin-liang-phd","display_name":"Shun-Hsin Liang, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-liang-shun-hsin-e1765414149534.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-liang-shun-hsin-e1765414149534.png"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Shun-Hsin","last_name":"Liang","user_url":"https:\/\/www.linkedin.com\/in\/shun-hsin-liang-174423123\/","job_title":"Senior Principal Scientist, LC Solution","description":"Shun-Hsin is a senior principal scientist in LC Solutions at Restek. He received his bachelor\u2019s degree from the National Taiwan University in 1988 and obtained his PhD from Michigan State University in 1996. He performed postdoctoral research at the University of Michigan from 1996 to 2000 for oncology studies. In 2001, he was appointed as research faculty at The Pennsylvania State University and focused on molecular toxicology research. In 2006, he joined MPI Research Inc. as a senior research scientist and was a study director for GLP analytical projects. In 2013, Dr. Liang joined the LC Solutions department at Restek and specialized in developing application methods across the fields of environmental, food safety, and life sciences."},{"term_id":702,"user_id":0,"is_guest":1,"slug":"justin-steimling","display_name":"Justin Steimling","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Justin","last_name":"Steimling","user_url":"https:\/\/www.linkedin.com\/in\/justin-steimling-959729167\/","job_title":"R&D, LC Solutions","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45338","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/46"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=45338"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45338\/revisions"}],"predecessor-version":[{"id":94002,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/45338\/revisions\/94002"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6403"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=45338"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=45338"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=45338"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=45338"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=45338"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=45338"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=45338"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=45338"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=45338"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}