{"id":48532,"date":"2025-06-24T00:00:00","date_gmt":"2025-06-24T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/from-customer-calls-to-sample-preparation-my-sabbatical-journey-into-sample-preparat-japan\/"},"modified":"2025-12-31T14:21:51","modified_gmt":"2025-12-31T14:21:51","slug":"from-customer-calls-to-sample-preparation-my-sabbatical-journey-into-sample-preparat-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4669-ja\/from-customer-calls-to-sample-preparation-my-sabbatical-journey-into-sample-preparat-japan","title":{"rendered":"EPA Method 1633A\u524d\u51e6\u7406\u306e\u5b9f\u52d9\u30ce\u30a6\u30cf\u30a6\u3068\u6ce8\u610f\u70b9\uff5ePFAS\u5206\u6790\u73fe\u5834\u7d4c\u9a13\u304b\u3089\u5f97\u305f\u3082\u306e"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">EPA Method 1633A\u306e\u524d\u51e6\u7406\u3067\u77e5\u3063\u3066\u304a\u304f\u3079\u304d\u5b9f\u52d9\u306e\u30b3\u30c4<\/h2>\n\n\n\n<p>\u79c1\u306f\u6280\u8853\u30b5\u30fc\u30d3\u30b9\u62c5\u5f53\u3068\u3057\u3066\u3001\u65e5\u3005\u304a\u5ba2\u69d8\u304b\u3089\u306e\u554f\u3044\u5408\u308f\u305b\u5bfe\u5fdc\u306b\u52a0\u3048\u3001\u6d88\u8017\u54c1\u3084\u88c5\u7f6e\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u3001\u88fd\u54c1\u9078\u5b9a\u3001\u3055\u3089\u306b\u306f\u5206\u6790\u4e0a\u306e\u8ab2\u984c\u89e3\u6c7a\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u6280\u8853\u652f\u63f4\u696d\u52d9\u306b\u53d6\u308a\u7d44\u3093\u3067\u3044\u307e\u3059\u30022025\u5e742\u6708\u3001\u5e78\u904b\u306b\u3082\u793e\u5185\u306e\u30b5\u30d0\u30c6\u30a3\u30ab\u30eb\uff08\u81ea\u5df1\u7814\u947d\uff09\u30d7\u30ed\u30b0\u30e9\u30e0\u306b\u53c2\u52a0\u3059\u308b\u6a5f\u4f1a\u3092\u5f97\u3066\u3001\u4e00\u5b9a\u671f\u9593\u30e9\u30dc\u306b\u8eab\u3092\u7f6e\u304d\u3001\u5b9f\u9a13\u696d\u52d9\u306b\u5c02\u5ff5\u3059\u308b\u3053\u3068\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u3044\u308f\u3070\u300c\u73fe\u5834\u5fa9\u5e30\u300d\u3068\u3082\u3044\u3048\u308b\u3053\u306e\u671f\u9593\u306b\u3001\u79c1\u306f\u73fe\u5728\u6ce8\u76ee\u3055\u308c\u3066\u3044\u308b\u5206\u6790\u624b\u6cd5\u306e\u3072\u3068\u3064\u3067\u3042\u308bEPA Method 1633A\u306b\u53d6\u308a\u7d44\u3080\u3053\u3068\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u6c34\u3001\u571f\u58cc\u3001\u30d0\u30a4\u30aa\u30bd\u30ea\u30c3\u30c9\u3068\u3044\u3063\u305f\u3055\u307e\u3056\u307e\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u306e\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff08PFAS\uff09\u3092\u9ad8\u611f\u5ea6\u3067\u691c\u51fa\u3059\u308b\u305f\u3081\u306b\u8a2d\u8a08\u3055\u308c\u305f\u3082\u306e\u3067\u3059\u3002<\/p>\n\n\n\n<p>\u672c\u7a3f\u3067\u306f\u3001\u79c1\u304c\u3053\u306e\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u901a\u3058\u3066\u5f97\u305f\u77e5\u898b\u3092\u3082\u3068\u306b\u3001EPA Method 1633A\u306b\u304a\u3051\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306e\u5b9f\u52d9\u7684\u306a\u30dd\u30a4\u30f3\u30c8\u3092\u3001\u73fe\u5834\u76ee\u7dda\u3067\u3054\u7d39\u4ecb\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">EPA Method 1633A\u3068\u306f<\/h2>\n\n\n\n<p>EPA Method 1633A\u306f\u3001\u6392\u6c34\u3001\u8868\u5c64\u6c34\u3001\u5730\u4e0b\u6c34\u3001\u571f\u58cc\u3001\u5806\u7a4d\u7269\u3001\u30d0\u30a4\u30aa\u30bd\u30ea\u30c3\u30c9\u3001\u9b5a\u306e\u7d44\u7e54\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u74b0\u5883\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u306e40\u7a2e\u306ePFAS\u3092\u5bfe\u8c61\u3068\u3059\u308b\u3001\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u30d9\u30fc\u30b9\u306e\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u3067\u3059\u3002PFAS\u306f\u6975\u3081\u3066\u5b89\u5b9a\u3057\u3066\u304a\u308a\u74b0\u5883\u4e2d\u306b\u9577\u671f\u9593\u6b8b\u7559\u3059\u308b\u6027\u8cea\u304b\u3089\u3001\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\u300d\u3068\u3082\u547c\u3070\u308c\u307e\u3059\u3002Method 1633A\u306f\u3001\u305d\u308c\u3089\u30921\u5146\u5206\u306e1\uff08ppt\uff09\u30ec\u30d9\u30eb\u3067\u691c\u51fa\u53ef\u80fd\u306a\u9ad8\u611f\u5ea6\u306e\u624b\u6cd5\u3067\u3042\u308a\u3001\u898f\u5236\u5f53\u5c40\u30fb\u74b0\u5883\u5206\u6790\u30e9\u30dc\u304b\u3089\u975e\u5e38\u306b\u9ad8\u3044\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u3000\u3000<\/p>\n\n\n\n<p>\u3057\u304b\u3057\u3001\u305d\u306e\u7cbe\u7dfb\u306a\u5206\u6790\u306b\u4e0d\u53ef\u6b20\u306a\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306f\u3001\u5316\u5b66\u306e\u77e5\u8b58\u304c\u3042\u3063\u3066\u3082\u7fd2\u5f97\u306b\u6642\u9593\u304c\u304b\u304b\u308b\u3068\u3001\u5b9f\u52d9\u3092\u901a\u3058\u3066\u305d\u306e\u30cf\u30fc\u30c9\u30eb\u306e\u9ad8\u3055\u3092\u75db\u611f\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5c0e\u5165\u6bb5\u968e\u306b\u304a\u3051\u308bPFAS\u5206\u6790\u30e9\u30dc\u3067\u306e\u5b9f\u52d9\u4e0a\u306e\u6ce8\u610f\u70b9\u3068\u5b66\u3073<\/h2>\n\n\n\n<p>\u79c1\u306f\u5408\u6210\u5316\u5b66\u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3092\u6301\u3061\u3001\u3053\u308c\u307e\u3067\u88fd\u85ac\u7cfb\u304a\u3088\u3073\u5927\u9ebb\u691c\u67fb\u30e9\u30dc\u3067\u591a\u304f\u306e\u5206\u6790\u696d\u52d9\u306b\u643a\u308f\u3063\u3066\u304d\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u306b\u3064\u3044\u3066\u306f\u307b\u3068\u3093\u3069\u7d4c\u9a13\u304c\u306a\u304f\u3001\u6700\u521d\u306e\u6570\u65e5\u306f\u6163\u308c\u306a\u3044\u5de5\u7a0b\u306b\u6238\u60d1\u3046\u5834\u9762\u3082\u591a\u304f\u3001\u8b19\u865a\u3055\u3068\u591a\u304f\u306e\u5b66\u3073\u306b\u6e80\u3061\u305f\u6642\u9593\u3067\u3057\u305f\u3002\u7279\u306b\u3001\u4ee5\u4e0b\u306e\u30dd\u30a4\u30f3\u30c8\u306b\u3064\u3044\u3066\u306f\u3001\u5b9f\u52d9\u3092\u901a\u3057\u3066\u6df1\u304f\u7406\u89e3\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u62bc\u3055\u3048\u308b\u3079\u304d\u30dd\u30a4\u30f3\u30c8:<\/h3>\n\n\n\n<p>\u2022 <strong>\u30b5\u30f3\u30d7\u30eb\u53d6\u308a\u6271\u3044\u306e\u57fa\u672c&nbsp;<\/strong>\u2013 \u4f7f\u7528\u3059\u308b\u5bb9\u5668\u3072\u3068\u3064\u306b\u3082\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002PFAS\u306f\u4e00\u90e8\u306e\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3084PTFE\u88fd\u54c1\u304b\u3089\u6eb6\u51fa\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u5bb9\u5668\u3084\u5b9f\u9a13\u5668\u5177\u306e\u6750\u8cea\u9078\u5b9a\u306f\u6975\u3081\u3066\u91cd\u8981\u3067\u3059\u3002<br>\u2022&nbsp;<strong>\u6c5a\u67d3\u7ba1\u7406\uff08\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\uff09<\/strong> \u2013 \u3053\u308c\u306f\u5358\u306b\u4f5c\u696d\u74b0\u5883\u3092\u300c\u6e05\u6f54\u300d\u306b\u4fdd\u3064\u3068\u3044\u3046\u30ec\u30d9\u30eb\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002PFAS\u30b3\u30f3\u30bf\u30df\u306f\u81f3\u308b\u6240\u3067\u767a\u751f\u3057\u307e\u3059\u3002\u74b0\u5883\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u306ePFAS\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u30d6\u30e9\u30f3\u30af\u30b5\u30f3\u30d7\u30eb\u3084\u30b9\u30d1\u30a4\u30af\u30b5\u30f3\u30d7\u30eb\u3092\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u306f\u3001\u30c7\u30fc\u30bf\u306e\u4fe1\u983c\u6027\u3092\u62c5\u4fdd\u3059\u308b\u305f\u3081\u306b\u4e0d\u53ef\u6b20\u3067\u3059\u3002<br>\u2022&nbsp;<strong>\u6eb6\u5a92\u306e\u53d6\u308a\u6271\u3044\u3068pH\u8abf\u6574<\/strong> \u2013 \u62bd\u51fa\u52b9\u7387\u306b\u5f71\u97ff\u3059\u308bpH\u7ba1\u7406\u306f\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002pH\u304c\u9069\u6b63\u7bc4\u56f2\u304b\u3089\u5916\u308c\u308b\u3068\u3001\u524d\u51e6\u7406\u306e\u6bb5\u968e\u3067\u5bfe\u8c61\u5316\u5408\u7269\u306e\u4e00\u90e8\u304c\u5931\u308f\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<br>\u2022&nbsp;<strong>\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09<\/strong> \u2013 SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3001\u6d41\u901f\u5236\u5fa1\u3001\u4e7e\u71e5\u65b9\u6cd5\u306a\u3069\u3001\u4e00\u9023\u306e\u64cd\u4f5c\u306f\u6975\u3081\u3066\u7e4a\u7d30\u3067\u3059\u3002\u4e7e\u71e5\u304c\u4e0d\u5341\u5206\u3060\u3068\u6c34\u5206\u304c\u6b8b\u308a\u3001\u904e\u4e7e\u71e5\u3067\u306f\u56de\u53ce\u7387\u304c\u4f4e\u4e0b\u3057\u307e\u3059\u3002\u6700\u9069\u306a\u8a2d\u5b9a\u306f\u7d4c\u9a13\u3092\u901a\u3057\u3066\u3057\u304b\u77e5\u308a\u5f97\u306a\u3044\u3001\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306e\u6700\u3082\u91cd\u8981\u306a\u5de5\u7a0b\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3068\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u9078\u5b9a<\/h3>\n\n\n\n<p>\u6570\u304b\u6708\u9593\u3001\u7a3c\u50cd\u4e2d\u306e\u30e9\u30dc\u306b\u53c2\u52a0\u3059\u308b\u3053\u3068\u81ea\u4f53\u306f\u96e3\u3057\u304f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u3001\u5e38\u99d0\u3057\u3066\u3044\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u30c1\u30fc\u30e0\u306b\u3068\u3063\u3066\u306f\u3001\u79c1\u3092\u53d7\u3051\u5165\u308c\u308b\u305f\u3081\u306e\u4e8b\u524d\u306e\u8a08\u753b\u3068\u6e96\u5099\u304c\u5fc5\u8981\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<p>\u79c1\u304c\u30b5\u30d0\u30c6\u30a3\u30ab\u30eb\u3092\u958b\u59cb\u3057\u305f\u9803\u3001\u7570\u306a\u308b\u74b0\u5883\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u6700\u9069\u306a\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u9078\u5b9a\u3068\u3001\u524d\u51e6\u7406\u30d5\u30ed\u30fc\u306e\u6539\u5584\u3092\u76ee\u7684\u3068\u3057\u305f\u3001\u3042\u308b\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u304c\u9032\u884c\u4e2d\u3060\u3063\u305f\u304b\u3089\u3067\u3059\u3002<\/p>\n\n\n\n<p>\u524d\u51e6\u7406\u30e9\u30dc\u3067\u306f\u4ee5\u4e0b\u306e3\u7a2e\u985e\u306eSPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3092\u6bd4\u8f03\u691c\u8a0e\u3057\u3066\u3044\u307e\u3057\u305f\u3002<br><strong>\u25e6 WAX\u5358\u72ec\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/strong><br><strong>\u25e6 \u7a4d\u5c64\u578b\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\uff08WAX + CarboPrep Plus\uff09<\/strong><br><strong>\u25e6 \u30d5\u30a3\u30eb\u30bf\u30fc\u30a8\u30a4\u30c9\u3092\u542b\u3080PFAS\u30c7\u30e5\u30a2\u30eb\u30d9\u30c3\u30c9\u578b\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8<\/strong><br>\u305d\u308c\u305e\u308c\u306e\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306f\u3001\u4fdd\u6301\u7279\u6027\u3084\u308d\u904e\u52b9\u7387\u304c\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3054\u3068\u306b\u5927\u304d\u304f\u7570\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u5bfe\u8c61\u306b\u5fdc\u3058\u305f\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u9078\u5b9a\u3068\u30d7\u30ed\u30bb\u30b9\u5236\u5fa1\u304c\u4e0d\u53ef\u6b20\u3067\u3042\u308b\u3053\u3068\u3092\u5b66\u3073\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Method 1633A\u306b\u3088\u308bLC-MS\/MS\u3092\u7528\u3044\u305fPFAS\u5b9a\u91cf<\/h2>\n\n\n\n<p>EPA Method 1633A\u306f\u3001LC-MS\/MS\uff08\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u2013\u30bf\u30f3\u30c7\u30e0\u8cea\u91cf\u5206\u6790\uff09\u3092\u7528\u3044\u3066PFAS\u3092\u5b9a\u91cf\u3057\u307e\u3059\u3002\u5e78\u3044\u3001\u79c1\u304c\u30e9\u30dc\u306b\u5165\u3063\u305f\u6642\u70b9\u3067\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306f\u3059\u3067\u306b\u78ba\u7acb\u3055\u308c\u3066\u304a\u308a\u3001\u3059\u3050\u306b\u904b\u7528\u53ef\u80fd\u306a\u72b6\u614b\u3067\u3057\u305f\u3002\u3068\u306f\u3044\u3048\u3001\u81ea\u5206\u306e\u624b\u3067LC\u30b5\u30f3\u30d7\u30eb\u3092\u6271\u3046\u306e\u306f\u7d045\u5e74\u3076\u308a\u3060\u3063\u305f\u306e\u3067\u3001\u305d\u306e\u30d7\u30ed\u30bb\u30b9\u3092\u518d\u78ba\u8a8d\u3057\u306a\u304c\u3089\u3001\u6700\u65b0\u306e\u88c5\u7f6e\u3068\u64cd\u4f5c\u624b\u9806\u306b\u6539\u3081\u3066\u5411\u304d\u5408\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u3000<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5fcd\u8010\u3068\u6ce8\u610f\u529b\u304c\u8981\u6c42\u3055\u308c\u308b\u696d\u52d9:<\/h3>\n\n\n\n<p>\u6700\u3082\u5370\u8c61\u7684\u3060\u3063\u305f\u306e\u306f\u3001\u3053\u306e\u696d\u52d9\u306e\u7dfb\u5bc6\u3055\u3067\u3059\u3002\u8fd1\u9053\u306f\u5b58\u5728\u305b\u305a\u3001\u4e00\u3064\u3072\u3068\u3064\u306e\u5de5\u7a0b\u3092\u4e01\u5be7\u306b\u7a4d\u307f\u91cd\u306d\u308b\u3057\u304b\u3042\u308a\u307e\u305b\u3093\u3002\u4f7f\u7528\u3059\u308b\u30e1\u30bf\u30ce\u30fc\u30eb\u306e\u30b0\u30ec\u30fc\u30c9\u304b\u3089\u30b5\u30f3\u30d7\u30eb\u306e\u56de\u53ce\u5bb9\u5668\u306e\u7a2e\u985e\u306b\u81f3\u308b\u307e\u3067\u3001\u3059\u3079\u3066\u306e\u8981\u7d20\u304c\u7d50\u679c\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u304b\u3089\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u73fe\u5834\u7d4c\u9a13\u304b\u3089\u898b\u3048\u305fEPA Method 1633A\u306e\u5b9f\u52d9\u8ab2\u984c\u3068\u6280\u8853\u30b5\u30dd\u30fc\u30c8\u3078\u306e\u6d3b\u304b\u3057\u65b9<\/h2>\n\n\n\n<p>\u73fe\u5728\u3001\u79c1\u306f\u6280\u8853\u30b5\u30fc\u30d3\u30b9\u306e\u696d\u52d9\u306b\u5fa9\u5e30\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u4ee5\u524d\u306e\u3088\u3046\u306b\u5358\u306bEPA Method 1633A\u306b\u3064\u3044\u3066\u8aac\u660e\u3059\u308b\u3060\u3051\u3067\u306f\u306a\u304f\u306a\u308a\u307e\u3057\u305f\u3002\u4eca\u306f\u3001\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u5b9f\u969b\u306b\u73fe\u5834\u3067\u6271\u3063\u305f\u7d4c\u9a13\u3092\u3082\u3068\u306b\u3001\u304a\u5ba2\u69d8\u306e\u8ab2\u984c\u3084\u60a9\u307f\u306b\u3088\u308a\u6df1\u304f\u5bc4\u308a\u6dfb\u3048\u308b\u3088\u3046\u306b\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u305f\u3068\u3048\u3070\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u3067SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306b\u76ee\u8a70\u307e\u308a\u304c\u767a\u751f\u3059\u308b\u3053\u3068\u3084\u3001\u771f\u7a7a\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u306e\u6d41\u901f\u5236\u5fa1\u306b\u624b\u3092\u713c\u304f\u3053\u3068\u3002\u3055\u3089\u306b\u306f\u3001\u56de\u53ce\u7387\u306b\u76f4\u7d50\u3059\u308bpH\u8abf\u6574\u3084\u6eb6\u5a92\u7ba1\u7406\u306e\u96e3\u3057\u3055\u306a\u3069\u3002\u73fe\u5834\u306b\u7acb\u3064\u307e\u3067\u60f3\u50cf\u3067\u304d\u306a\u304b\u3063\u305f\u7d30\u304b\u306a\u300c\u3064\u307e\u305a\u304d\u300d\u3092\u5b9f\u969b\u306b\u4f53\u9a13\u3067\u304d\u305f\u304b\u3089\u3053\u305d\u306e\u30b5\u30dd\u30fc\u30c8\u304c\u3067\u304d\u3066\u3044\u308b\u306f\u305a\u3067\u3059\u3002<\/p>\n\n\n\n<p>\u3053\u306e\u30b5\u30d0\u30c6\u30a3\u30ab\u30eb\u306f\u3001\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306e\u80cc\u5f8c\u306b\u3042\u308b\u300c\u4eba\u306e\u4f5c\u696d\u300d\u306e\u30ea\u30a2\u30eb\u3092\u601d\u3044\u51fa\u3055\u305b\u3066\u304f\u308c\u307e\u3057\u305f\u3002\u8ab0\u304b\u304c\u30b5\u30f3\u30d7\u30eb\u3092\u7c89\u7815\u3057\u3001\u30d5\u30ed\u30fc\u3092\u898b\u5b88\u308a\u3001\u6570\u5024\u3092\u4f55\u5ea6\u3082\u78ba\u8a8d\u3057\u3066\u3044\u308b\u3002\u305d\u3046\u3057\u305f\u4e01\u5be7\u306a\u7a4d\u307f\u91cd\u306d\u304c\u3001\u3088\u3046\u3084\u304f\u4fe1\u983c\u3067\u304d\u308b\u30c7\u30fc\u30bf\u306b\u3064\u306a\u304c\u3063\u3066\u3044\u308b\u306e\u3060\u3068\u3001\u6539\u3081\u3066\u611f\u3058\u307e\u3057\u305f\u3002PFAS\u306b\u95a2\u3059\u308b\u898f\u5236\u304c\u5e74\u3005\u5f37\u5316\u3055\u308c\u308b\u4e2d\u3001EPA Method 1633A\u306e\u91cd\u8981\u6027\u306f\u4eca\u5f8c\u307e\u3059\u307e\u3059\u9ad8\u307e\u3063\u3066\u3044\u304f\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p>\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u6271\u3046\u304a\u5ba2\u69d8\u3092\u652f\u63f4\u3059\u308b\u7acb\u5834\u306b\u3042\u308b\u65b9\u306a\u3089\u3001\u305c\u3072\u4e00\u5ea6\u30e9\u30dc\u3067\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306e\u5de5\u7a0b\u3092\u5b9f\u969b\u306b\u4f53\u9a13\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002\u305f\u3068\u3048\u6570\u65e5\u3067\u3082\u3001\u81ea\u5206\u306e\u624b\u3067\u89e6\u308c\u3066\u307f\u308b\u3053\u3068\u3067\u3001\u30b5\u30dd\u30fc\u30c8\u306e\u8cea\u304c\u5927\u304d\u304f\u5909\u308f\u308b\u3053\u3068\u306b\u6c17\u3065\u304f\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>EPA Method 1633A\u306f\u6c34\u3084\u571f\u58cc\u306a\u3069\u74b0\u5883\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u306ePFAS\u3092\u9ad8\u611f\u5ea6\u3067\u5206\u6790\u3067\u304d\u308b\u6ce8\u76ee\u306e\u624b\u6cd5\u3067\u3059\u3002\u73fe\u5834\u7d4c\u9a13\u304b\u3089\u5f97\u3089\u308c\u305f\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306b\u304a\u3051\u308b\u5931\u6557\u3092\u907f\u3051\u308b\u5b9f\u52d9\u30dd\u30a4\u30f3\u30c8\u3084\u3001\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u9078\u5b9a\u30fbSPE\u64cd\u4f5c\u306e\u30b3\u30c4\u3001\u6ce8\u610f\u3059\u3079\u304d\u8ab2\u984c\u307e\u3067\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":52,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[794],"tags":[],"industries-application":[2288,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2365,2346,2343,2345],"ppma_author":[607],"class_list":["post-48532","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","industries-application-pfas-testing-ja","industries-application-environmental-ja","resource-technique-ms-ms-ja","resource-technique-solid-phase-extraction-spe-ja","resource-technique-liquid-chromatography-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2346,"label":"\u56fa\u76f8\u62bd\u51fa (SPE)"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Kevin Albertson","author_link":"https:\/\/discover.restek.com\/ja\/author\/kevin-albertson\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":444,"filter":"raw","cat_ID":794,"category_count":444,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":607,"user_id":52,"is_guest":0,"slug":"kevin-albertson","display_name":"Kevin Albertson","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/albertson-kevin.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/albertson-kevin.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48532","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/52"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48532"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48532\/revisions"}],"predecessor-version":[{"id":79003,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48532\/revisions\/79003"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48532"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48532"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48532"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48532"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48532"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48532"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48532"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48532"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48532"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}