{"id":48534,"date":"2012-07-26T14:30:00","date_gmt":"2012-07-26T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-to-choose-the-correct-gc-column-part-2-japan\/"},"modified":"2026-01-21T18:15:08","modified_gmt":"2026-01-21T18:15:08","slug":"how-to-choose-the-correct-gc-column-part-2-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4704-ja\/how-to-choose-the-correct-gc-column-part-2-japan","title":{"rendered":"GC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3\u3010\u7b2c2\u56de\u3011\u30ab\u30e9\u30e0\u9078\u3073\u306b\u6b20\u304b\u305b\u306a\u3044\u8996\u70b9\u3001\u6975\u6027"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u7b2c1\u56de\u306e\u300c\u6cb8\u70b9\u300d\u306b\u7d9a\u304d\u3001\u7b2c2\u56de\u3067\u306fGC\u30ab\u30e9\u30e0\u9078\u629e\u3067\u91cd\u8981\u306a\u5f79\u5272\u3092\u679c\u305f\u3059\u3001\u5316\u5408\u7269\u306e\u300c\u6975\u6027\u300d\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" rel=\"noreferrer noopener\">\u7b2c1\u56de\u306e\u300c\u6cb8\u70b9\u304b\u3089\u59cb\u3081\u308b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u3073\u300d<\/a>\u306b\u8a18\u8f09\u3057\u305f\u30d7\u30ed\u30bb\u30b9\u3092\u632f\u308a\u8fd4\u3063\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><em><strong>4\u3064\u306eGC\u30ab\u30e9\u30e0\u9078\u629e\u57fa\u6e96:<\/strong><\/em><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">1.\u00a0 \u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u306e<strong>\u6cb8\u70b9<\/strong>\uff08<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" rel=\"noreferrer noopener\">\u7b2c1\u56de<\/a>\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2.&nbsp; \u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u306e<strong>\u6975\u6027<\/strong>\uff08\u304a\u3088\u3073\u8a72\u5f53\u3059\u308b\u5834\u5408\u306f\u30b5\u30f3\u30d7\u30eb\uff0f\u6a19\u6e96\u6eb6\u5a92\u306e\u6975\u6027\uff09\uff08\u7b2c2\u56de\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.\u00a0 \u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u306e<strong>\u6fc3\u5ea6\u3001\u30ab\u30e9\u30e0\u5bb9\u91cf\u3001\u691c\u51fa\u5668\u306e\u7a2e\u985e<\/strong>\uff08<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4705-ja\/how-to-choose-the-correct-gc-column-part-3-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4705-ja\/how-to-choose-the-correct-gc-column-part-3-japan\" rel=\"noreferrer noopener\">\u7b2c3\u56de<\/a>\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4.\u00a0 \u305d\u306e\u4ed6\u3001\u9078\u629e\u80a2\u3092\u3055\u3089\u306b\u7d5e\u308a\u8fbc\u3080\u305f\u3081\u306e<strong>\u8a73\u7d30\u60c5\u5831<\/strong>\uff08<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4706-ja\/how-to-choose-the-correct-gc-column-part-4-japan\" target=\"_blank\" rel=\"noreferrer noopener\">\u7b2c4\u56de<\/a>\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f7f\u7528\u3059\u3079\u304d\u30ab\u30e9\u30e0\u306e\u9078\u629e\u80a2\u3092\u4e0a\u8a18\u306e\u57fa\u6e96\u306b\u3088\u3063\u3066\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a4\u3064\u306e\u30ab\u30e9\u30e0\u30ab\u30c6\u30b4\u30ea\u306b\u5206\u985e\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><em><strong>4\u3064\u306e\u30ab\u30e9\u30e0\u30ab\u30c6\u30b4\u30ea:<\/strong><\/em><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">A. \u30ac\u30b9\u5206\u6790\u7528\u30ab\u30e9\u30e0\uff08\u70ad\u7d20\u304a\u3088\u3073\u30bc\u30aa\u30e9\u30a4\u30c8<a href=\"https:\/\/www.restek.com\/global\/ja\/search?Ntt=molecular+sieve&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\">\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6<\/a>\u3001\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u3001\u30b7\u30ea\u30ab\u30b2\u30eb\u306a\u3069\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">B. \u63ee\u767a\u6027\u5316\u5408\u7269\u7528\u30ab\u30e9\u30e0\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1717\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-VMS<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1674\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-624Silms<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1702\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-502.2<\/a>\u306a\u3069\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">C. \u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u7528\u30ab\u30e9\u30e0\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1679\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-5Sil ms<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1682\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-35Sil ms<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1686\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-17Sil ms<\/a>\u306a\u3069\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">D. \u9ad8\u6e29\u7528\u30ab\u30e9\u30e0\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1744\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-Biodiesel<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1731\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-1HT<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1741\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-2887<\/a>\u306a\u3069\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u3001\u5316\u5b66\u7684\u306a\uff08\u5206\u5b50\u306e\uff09<strong>\u6975\u6027<\/strong>\u306b\u3064\u3044\u3066\u7c21\u5358\u306b\u8aac\u660e\u3057\u307e\u3057\u3087\u3046\u3002\u6700\u3082\u6975\u6027\u306e\u4f4e\u3044\u3082\u306e\u306f\u3001\u76f4\u9396\u70ad\u5316\u6c34\u7d20\uff08\u5bfe\u79f0\u7684\u306aC-H\u7d50\u5408\u3001\u975e\u6975\u6027\u5171\u6709\u7d50\u5408\uff09\u3067\u3042\u308a\u3001\u6975\u6027\u306e\u9ad8\u3044\u3082\u306e\u306f\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u3084\u6c34\uff08\u975e\u5bfe\u79f0\u7684\u306aO-H\u7d50\u5408\u3001\u6975\u6027\u5171\u6709\u7d50\u5408\uff09\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><a href=\"http:\/\/en.wikipedia.org\/wiki\/Chemical_polarity\" target=\"_blank\" rel=\"noreferrer noopener\">Chemical polarity<\/a>\uff08\u82f1\u8a9eWikipedia\u30da\u30fc\u30b8\uff09<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u3010\u975e\u6975\u6027\u3011\u30e1\u30bf\u30f3\u306e\u69cb\u9020 (\u51fa\u5178\uff1aWikipedia)<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"100\" height=\"117\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-2-01.png\" alt=\"\" class=\"wp-image-15135\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">\u3010\u9ad8\u6975\u6027\u3011\u30e1\u30bf\u30ce\u30fc\u30eb\u306e\u69cb\u9020(\u51fa\u5178\uff1aWikipedia)<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"180\" height=\"116\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-2-02.png\" alt=\"\" class=\"wp-image-15141\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u6975\u6027\u3092\u7406\u89e3\u3057\u305f\u3089\u601d\u3044\u51fa\u3057\u3066\u6b32\u3057\u3044\u306e\u306f\u3001\u300c\u4f3c\u305f\u8005\u540c\u58eb\u306f\u3088\u304f\u6eb6\u3051\u308b\u300d\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u5206\u6790\u306e\u969b\u306b\u91cd\u8981\u306a\u306e\u306f\u3001\u6a19\u6e96\u8a66\u6599\u306e\u524d\u51e6\u7406\u306b\u4f7f\u7528\u3059\u308b\u6eb6\u5a92\u306e\u6975\u6027\u3092\u628a\u63e1\u3057\u3001\u76f8\u4e92\u306b\u985e\u4f3c\u3055\u305b\u308b\u3053\u3068\u3067\u3059\u3002\u7d50\u679c\u3068\u3057\u3066\u3001\u5b89\u5b9a\u3057\u305f\u6eb6\u89e3\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u76f4\u9396\u70ad\u5316\u6c34\u7d20\uff08\u975e\u6975\u6027\uff09\u306e\u524d\u51e6\u7406\u306b\u3001\u30d8\u30ad\u30b5\u30f3\u3001\u30c8\u30eb\u30a8\u30f3\u3001\u4e8c\u786b\u5316\u70ad\u7d20\u306e\u3088\u3046\u306a\u975e\u6975\u6027\u6eb6\u5a92\u3092\u4f7f\u7528\u3059\u308b\u306e\u304c\u826f\u3044\u4f8b\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5316\u5408\u7269\u3084\u6eb6\u5a92\u306e\u6975\u6027\u306b\u95a2\u3059\u308b\u60c5\u5831\u304c\u5f97\u3089\u308c\u308b\u30b5\u30a4\u30c8\u3082\u3042\u308a\u307e\u3059\u306e\u3067\u3001\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff08\u5916\u90e8\u30ea\u30f3\u30af\uff09\u3002<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><a href=\"http:\/\/murov.info\/orgsolvents.htm\" target=\"_blank\" rel=\"noreferrer noopener\">Properties of organic solvents<\/a><\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><a href=\"http:\/\/en.wikipedia.org\/wiki\/Solvent\" target=\"_blank\" rel=\"noreferrer noopener\">Physical properties of common solvents<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u306e\u9078\u629e\u80a2\u3092\u7d5e\u308a\u8fbc\u3080\u969b\u306f\u3001\u307e\u305a\u6700\u521d\u306b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u6975\u6027\u306b\u985e\u4f3c\u3057\u305f\u30ab\u30e9\u30e0\u6db2\u76f8\u3092\u9078\u3073\u307e\u3059\u3002\u3053\u306e\u7d50\u679c\u3001\u8a66\u6599\u3068\u6db2\u76f8\u306e\u6eb6\u89e3\u529b\u304c\u9ad8\u304f\u306a\u308a\u3001\u6e2c\u5b9a\u7269\u8cea\u306e\u4fdd\u6301\u304c\u9ad8\u304f\u306a\u308a\u307e\u3059\u3002\u6e2c\u5b9a\u7269\u8cea\u3068\u30ab\u30e9\u30e0\u306e\u6975\u6027\u304c\u9055\u3046\u5834\u5408\u3001\u6db2\u76f8\u306b\u5bfe\u3059\u308b\u6eb6\u89e3\u529b\u304c\u4f4e\u304f\u306a\u308a\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u7570\u5e38\uff08\u4f8b\u3048\u3070\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30d4\u30fc\u30af\uff09\u306a\u3069\u304c\u767a\u751f\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b5\u30f3\u30d7\u30eb\/\u6a19\u6e96\u6eb6\u6db2\u306e\u6eb6\u5a92\u3068\u3057\u3066\u63a8\u5968\u3055\u308c\u308b\u306e\u306f\u30a2\u30bb\u30c8\u30f3\u3001\u5869\u5316\u30e1\u30c1\u30ec\u30f3\u3001\u30d8\u30ad\u30b5\u30f3\u306e\u3088\u3046\u306aGC\u30ab\u30e9\u30e0\u306b\u9069\u3057\u305f\u6eb6\u5a92\u3067\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30d4\u30fc\u30af\u3084\u30c6\u30fc\u30ea\u30f3\u30b0\u30d4\u30fc\u30af\u306e\u3088\u3046\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u4e0a\u306e\u554f\u984c\u304c\u767a\u751f\u3059\u308b\u53ef\u80fd\u6027\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u9006\u306b\u907f\u3051\u305f\u65b9\u304c\u3044\u3044\u306e\u306f\u30af\u30ed\u30ed\u30db\u30eb\u30e0\u3001\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3001\u6c34\u306e\u3088\u3046\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u4e0a\u306e\u554f\u984c\u3092\u767a\u751f\u3055\u305b\u308b\u6eb6\u5a92\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u5f8c\u306b\u30014\u3064\u306e\u30ab\u30e9\u30e0\u30ab\u30c6\u30b4\u30ea\u5225\u306e\u3001\u6975\u6027\u306e\u7570\u306a\u308bGC\u30ab\u30e9\u30e0\u3092\u4ee5\u4e0b\u306e\u3068\u304a\u308a\u3054\u7d39\u4ecb\u3057\u3066\u304a\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>A. \u30ac\u30b9\u5206\u6790\u7528\u30ab\u30e9\u30e0<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u975e\u6975\u6027\/\u4f4e\u6975\u6027\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1753\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Q-Bond<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1754\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-QS-Bond<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1749\" target=\"_blank\" rel=\"noreferrer noopener\">Alumina\/KCl<\/a>, HayeSep Q &amp; D, Chromosorb T&nbsp;<br>\u4e2d\u6975\u6027\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1755\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-S-Bond<\/a>, HayeSep C, R &amp; S, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1751\" target=\"_blank\" rel=\"noreferrer noopener\">Alumina\/Na2SO4<\/a> &amp;<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1750\" target=\"_blank\" rel=\"noreferrer noopener\"> MAPD&nbsp;<\/a><br>\u9ad8\u6975\u6027\uff1a <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1756\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-U-Bond<\/a>, HayeSep B, N &amp; T&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>B. \u63ee\u767a\u6027\u5316\u5408\u7269\u7528\u30ab\u30e9\u30e0<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u975e\u6975\u6027\/\u4f4e\u6975\u6027\uff1a\u539a\u819c<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1688\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-1<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1689\" target=\"_blank\" rel=\"noopener\">Rtx-5<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1718\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-Volatile Amine&nbsp;<\/a><br>\u4e2d\u6975\u6027\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1717\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-VMS<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1702\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-502.2<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1703\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-624<\/a>, \u539a\u819c<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1704\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-1301<\/a>\u304a\u3088\u3073<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1698\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-200<\/a><br>\u9ad8\u6975\u6027\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1820\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax<\/a>\uff08DA \u304a\u3088\u3073 DB \u3092\u542b\u3080\uff09\u304a\u3088\u3073<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1721\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-Wax&nbsp;<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>C. \u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u7528\u30ab\u30e9\u30e0&nbsp;<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u975e\u6975\u6027\/\u4f4e\u6975\u6027\uff1a\u8584\u819c<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1676\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-1ms<\/a>,<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1675\" target=\"_blank\" rel=\"noreferrer noopener\"> Rxi-5ms<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1679\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-5Sil ms<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1678\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-XLB<\/a>&nbsp;<br>\u4e2d\u6975\u6027\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1673\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-17<\/a> (\u304a\u3088\u3073<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1686\" target=\"_blank\" rel=\"noreferrer noopener\">17Sil ms<\/a>), <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1682\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-35Sil ms<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1695\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-50<\/a>, \u8584\u819c<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1698\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-200<\/a>&nbsp;<br>\u9ad8\u6975\u6027\uff1aNA&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>D. \u9ad8\u6e29\u7528\u30ab\u30e9\u30e0<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u975e\u6975\u6027\/\u4f4e\u6975\u6027\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1683\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-1HT<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1685\" target=\"_blank\" rel=\"noreferrer noopener\">Rxi-5HT<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1744\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-\u30d0\u30a4\u30aa\u30c7\u30a3\u30fc\u30bc\u30eb<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1731\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-1HT<\/a>, <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1731\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-1 SimDist&nbsp;<\/a><br>\u4e2d\u6975\u6027\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1735\" target=\"_blank\" rel=\"noreferrer noopener\">MXT-65TG<\/a>&nbsp;<br>\u9ad8\u6975\u6027\uff1a NA<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" rel=\"noreferrer noopener\">\u7b2c1\u56de<\/a>\u3068\u7b2c2\u56de\u3067\u3054\u7d39\u4ecb\u3057\u305f\u9078\u629e\u57fa\u6e96\u306f\u8fc5\u901f\u306a\u30ab\u30e9\u30e0\u9078\u629e\u306e\u4e00\u52a9\u3068\u306a\u3063\u3066\u3044\u308b\u3068\u601d\u3044\u307e\u3059\u3002<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4705-ja\/how-to-choose-the-correct-gc-column-part-3-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4705-ja\/how-to-choose-the-correct-gc-column-part-3-japan\" rel=\"noreferrer noopener\">\u7b2c3\u56de<\/a>\u3067\u306f\u3001\u30ab\u30e9\u30e0\u5bb9\u91cf\u304a\u3088\u3073\u691c\u51fa\u5668\u306e\u9078\u629e\u306b\u3088\u3063\u3066\u30ab\u30e9\u30e0\u306e\u9078\u629e\u80a2\u7d5e\u308a\u8fbc\u307f\u3092\u3055\u3089\u306b\u30d6\u30e9\u30c3\u30b7\u30e5\u30a2\u30c3\u30d7\u3057\u307e\u3059\u3002\u7b2c3\u56de\u3082\u305c\u3072\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u30ab\u30e9\u30e0\u9078\u629e\u306e\u7b2c2\u56de\u306f\u6975\u6027\u306b\u7126\u70b9\u3002\u6975\u6027\u306e\u30df\u30b9\u30de\u30c3\u30c1\u304c\u5206\u96e2\u4e0d\u826f\u3092\u62db\u304f\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u89e3\u8aac\u3057\u3001\u9069\u5207\u306a\u56fa\u5b9a\u76f8\u306e\u9078\u3073\u65b9\u3092\u6307\u5357\u3002\u5206\u6790\u5316\u5b66\u8005\u304c\u77e5\u308b\u3079\u304d\u6975\u6027\u3068\u6eb6\u5a92\u306e\u95a2\u4fc2\u6027\u3001\u5206\u96e2\u6027\u80fd\u3092\u6700\u5927\u5316\u3059\u308b\u5b9f\u8df5\u7684\u306a\u624b\u6cd5\u3092\u7d39\u4ecb\u3002\u30b7\u30ea\u30fc\u30ba\u3092\u901a\u3058\u3066\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u52b9\u7387\u5316\u3092\u30b5\u30dd\u30fc\u30c8\u3002<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[2823],"class_list":["post-48534","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/ja\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48534","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48534"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48534\/revisions"}],"predecessor-version":[{"id":83672,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48534\/revisions\/83672"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48534"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48534"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48534"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48534"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48534"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48534"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48534"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48534"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48534"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}