{"id":48535,"date":"2012-08-06T14:30:00","date_gmt":"2012-08-06T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-to-choose-the-correct-gc-column-part-3-japan\/"},"modified":"2026-01-21T18:19:17","modified_gmt":"2026-01-21T18:19:17","slug":"how-to-choose-the-correct-gc-column-part-3-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4705-ja\/how-to-choose-the-correct-gc-column-part-3-japan","title":{"rendered":"GC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3\u3010\u7b2c3\u56de\u3011\u30ab\u30e9\u30e0\u5bb9\u91cf\u304a\u3088\u3073\u691c\u51fa\u5668\u306e\u611f\u5ea6\u7279\u6027\u3068\u76f4\u7dda\u6027"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u7b2c3\u56de\u3067\u306f\u3001GC\u30ab\u30e9\u30e0\u5bb9\u91cf\uff08\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\uff09\u3001\u691c\u51fa\u5668\u306e\u611f\u5ea6\u7279\u6027\u3001\u304a\u3088\u3073\u691c\u51fa\u5668\u306e\u76f4\u7dda\u6027\u3001\u3068\u3044\u3046\uff13\u3064\u306e\u8996\u70b9\u304b\u3089\u3001\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u629e\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002\u3053\u306e\u30d6\u30ed\u30b0\u3092\u8aad\u3080\u524d\u306b\u3001\u305c\u3072\u7b2c1\u56de\u3001\u7b2c2\u56de\u3082\u3054\u53c2\u7167\u4e0b\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" rel=\"noreferrer noopener\">GC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3\u00a0 \u7b2c1\u56de\uff1a\u6cb8\u70b9\u304b\u3089\u59cb\u3081\u308b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u3073<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4704-ja\/how-to-choose-the-correct-gc-column-part-2-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4704-ja\/how-to-choose-the-correct-gc-column-part-2-japan\" rel=\"noreferrer noopener\">GC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3\u00a0 \u7b2c2\u56de\uff1a\u30ab\u30e9\u30e0\u9078\u3073\u306b\u6b20\u304b\u305b\u306a\u3044\u8996\u70b9\u3001\u6975\u6027<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\uff11\uff0e\u30ab\u30e9\u30e0\u5bb9\u91cf\uff08\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\uff09\u3068\u306f\u4f55\u304b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u5bb9\u91cf\uff08\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\uff09\u306f\u3001\u30ab\u30e9\u30e0\u306e\u5185\u5f84\uff08ID\uff09\u3068\u819c\u539a\uff08\u00b5m df\uff09\u306b\u3088\u3063\u3066\u6c7a\u307e\u308a\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u3001\u540c\u3058\u5185\u5f84\u306e\u30ab\u30e9\u30e0\u3067\u306f\u819c\u539a\u304c\u539a\u3044\u307b\u3069\u30ab\u30e9\u30e0\u5bb9\u91cf\u306f\u5927\u304d\u304f\u306a\u308a\u3001\u4f8b\u3048\u3070\u819c\u539a1.0\u00b5m\u306e\u30ab\u30e9\u30e0\u306f0.5\u00b5m\u306e\u30ab\u30e9\u30e0\u306e\u7d042\u500d\u306e\u5bb9\u91cf\u3092\u6301\u3061\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30ab\u30e9\u30e0\u5bb9\u91cf\u306f\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u304c\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u306b\u6eb6\u89e3\u3059\u308b\u5ea6\u5408\u3044\u306b\u3082\u4f9d\u5b58\u3057\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u6eb6\u89e3\u6027\u304c\u4f4e\u3044\u5834\u5408\u30ab\u30e9\u30e0\u5bb9\u91cf\u306f\u5c0f\u3055\u304f\u306a\u308a\u3001\u5185\u5f84\u306e\u307f\u304c\u30ab\u30e9\u30e0\u5bb9\u91cf\u306e\u6c7a\u5b9a\u56e0\u5b50\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"772\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-01-JPsuzu-1024x772.png\" alt=\"\" class=\"wp-image-15147\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-01-JPsuzu-1024x772.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-01-JPsuzu-300x226.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-01-JPsuzu-768x579.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-01-JPsuzu.png 1081w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u5bb9\u91cf\u304c\u5927\u304d\u3044\u30ab\u30e9\u30e0\u306f\u591a\u91cf\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u5c0e\u5165\u3067\u304d\u308b\u305f\u3081\u3001\u691c\u51fa\u5668\u306e\u76f4\u7dda\u7bc4\u56f2\u5185\u3067\u306e\u5b9a\u91cf\u304c\u5bb9\u6613\u306b\u306a\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5185\u5f84\u3084\u819c\u539a\u304c\u5927\u304d\u3044\u30ab\u30e9\u30e0\u306f\u30d4\u30fc\u30af\u304c\u5e83\u304c\u308a\u3084\u3059\u304f\u3001\u611f\u5ea6\u4f4e\u4e0b\u3084\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u5897\u52a0\u306e\u30ea\u30b9\u30af\u3082\u3042\u308a\u307e\u3059\u3002\u5206\u96e2\u5bfe\u8c61\u306e\u5316\u5408\u7269\u306b\u3088\u3063\u3066\u30ab\u30e9\u30e0\u819c\u539a\u3092\u9078\u629e\u3057\u3001\u904e\u5270\u306a\u30ab\u30e9\u30e0\u5bb9\u91cf\u3092\u907f\u3051\u308b\u3053\u3068\u304c\u671b\u307e\u3057\u3044\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\uff12\uff0e\uff08\u8cea\u91cf\u5206\u6790\u8a08\u4ee5\u5916\u306e\uff09GC\u691c\u51fa\u5668\u306e\u611f\u5ea6\u7279\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u3067\u8aac\u660e\u3059\u308bTCD \u3092\u9664\u304d\u3001\u4e00\u822c\u7684\u306aGC\u691c\u51fa\u5668\u306f\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3068\u4f7f\u7528\u3059\u308b\u969b\u306b\u554f\u984c\u306a\u3044\u611f\u5ea6\u7279\u6027\u3092\u6301\u3063\u3066\u3044\u308b\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002\u305f\u3060\u3057\u3001GC\u691c\u51fa\u5668\u306b\u306f\u591a\u7a2e\u591a\u69d8\u306a\u3082\u306e\u304c\u3042\u308a\u3001\u305d\u308c\u305e\u308c\u7570\u306a\u308b\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u5bfe\u3057\u9ad8\u3044\u611f\u5ea6\u3092\u6301\u3061\u307e\u3059\u3002\u4ee3\u8868\u7684\u306a\u691c\u51fa\u5668\u306e\u611f\u5ea6\u7279\u6027\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 &nbsp; &nbsp;<strong>FID<\/strong>\uff08\u706b\u708e\u30a4\u30aa\u30f3\u5316\u691c\u51fa\u5668\uff09\uff1a\u70ad\u7d20-\u6c34\u7d20\u7d50\u5408\u3092\u6301\u3064\u6709\u6a5f\u5316\u5408\u7269\u306b\u9ad8\u611f\u5ea6\u3000C-H\u7d50\u5408\u304c\u591a\u3044\u307b\u3069\u611f\u5ea6\u306f\u5411\u4e0a<br>\u2022 &nbsp; &nbsp;<strong>ECD<\/strong>\uff08\u96fb\u5b50\u6355\u7372\u691c\u51fa\u5668\uff09\uff1a\u6709\u6a5f\u30cf\u30ed\u30b2\u30f3\u5316\u5408\u7269\u306b\u6975\u3081\u3066\u9ad8\u611f\u5ea6\u3000\u611f\u5ea6\u306e\u9806\u306fI &gt; Br &gt; Cl &gt; F<br>\u2022 &nbsp; &nbsp;<strong>NPD<\/strong>\uff08\u7a92\u7d20\u30ea\u30f3\u691c\u51fa\u5668\uff09\uff1a\u7a92\u7d20\u307e\u305f\u306f\u30ea\u30f3\u542b\u6709\u5316\u5408\u7269\u306b\u7279\u7570\u7684\u306b\u9ad8\u611f\u5ea6<br>\u2022 &nbsp; &nbsp;<strong>FPD<\/strong>\uff08\u708e\u5149\u5149\u5ea6\u691c\u51fa\u5668\uff09\uff1a\u786b\u9ec4\u3084\u30ea\u30f3\u542b\u6709\u5316\u5408\u7269\u306b\u7279\u7570\u7684\u306b\u9ad8\u611f\u5ea6<br>\u2022 &nbsp; &nbsp;<strong>PID<\/strong>\uff08\u5149\u30a4\u30aa\u30f3\u5316\u691c\u51fa\u5668\uff09\uff1aPID\u30e9\u30f3\u30d7\u306e\u51fa\u529b\u3088\u308a\u3082\u30a4\u30aa\u30f3\u5316\u30dd\u30c6\u30f3\u30b7\u30e3\u30eb\u304c\u4f4e\u3044\u5316\u5408\u7269\u306b\u9650\u5b9a\u3057\u3066\u691c\u51fa\u53ef\u80fd<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u2022 &nbsp; &nbsp;<strong>TCD<\/strong>\uff08\u71b1\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668\uff09\uff1a\u7406\u8ad6\u4e0a\u306f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u4ee5\u5916\u306e\u5168\u5316\u5408\u7269\u3092\u691c\u51fa\u53ef\u80fd\u3000\u4e00\u822c\u7684\u306aGC\u691c\u51fa\u5668\u4e2d\u3001\u611f\u5ea6\u306f\u6700\u3082\u4f4e\u3044\u30000.53mmID\u4ee5\u4e0a\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\uff08\u307e\u305f\u306f\u3088\u308aID\u306e\u5927\u304d\u3044\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u3082\u3057\u304f\u306f\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\uff09\u306e\u4f7f\u7528\u3092\u63a8\u5968\uff08\u30ab\u30e9\u30e0\u5bb9\u91cf\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u7279\u6027\u3092\u8e0f\u307e\u3048\u3001\u691c\u51fa\u5668\u306e\u7dda\u5f62\u7bc4\u56f2\u306b\u5408\u3063\u305f\u30ab\u30e9\u30e0\u5bb9\u91cf\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u3001\u5b9a\u91cf\u7cbe\u5ea6\u5411\u4e0a\u306b\u4e0d\u53ef\u6b20\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\uff13\uff0e\u691c\u51fa\u5668\u306e\u76f4\u7dda\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u306b\u5bfe\u3059\u308b\u691c\u51fa\u5668\u306e\u76f4\u7dda\u6027\u7bc4\u56f2\u306b\u3064\u3044\u3066\u691c\u8a0e\u3057\u307e\u3059\u3002\u691c\u51fa\u5668\u306e\u611f\u5ea6\u304c\u4e0d\u5341\u5206\u3001\u307e\u305f\u306f\u904e\u5ea6\u306b\u9ad8\u611f\u5ea6\u3067\u3042\u308b\u5834\u5408\u3001\u76f4\u7dda\u6027\u3092\u78ba\u4fdd\u3057\u3001\u518d\u73fe\u6027\u306e\u9ad8\u3044\u691c\u91cf\u7dda\u3092\u5f97\u308b\u305f\u3081\u306b\u30b5\u30f3\u30d7\u30eb\u30b5\u30a4\u30ba\u3084\u6fc3\u5ea6\u306e\u8abf\u6574\u304c\u5fc5\u8981\u3067\u3059\u3002\u7406\u60f3\u7684\u306a\u691c\u91cf\u7dda\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u76f4\u7dda\u7684\u306b\u6bd4\u4f8b\u3059\u308b\u5f62\u72b6\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u964d\u306b\u793a\u3059\u691c\u91cf\u7dda\u306e\u3059\u3079\u3066\u306b\u95a2\u3057\u3066\u3001<strong>\uff39\u8ef8\u306f\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u8868\u3057\u2191\u306e\u65b9\u5411\u3067\u5927\u304d\u304f\u306a\u308a<\/strong>\u3001<strong>\uff38\u8ef8\u306f\u6fc3\u5ea6\u3092\u8868\u3057\u2192\u306e\u65b9\u5411\u3067\u5927\u304d\u304f\u306a\u308a<\/strong>\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"916\" height=\"560\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-02.bmp\" alt=\"\" class=\"wp-image-15159\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-02.bmp 916w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-02-300x183.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-02-768x470.jpg 768w\" sizes=\"auto, (max-width: 916px) 100vw, 916px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u304c\u4f4e\u6fc3\u5ea6\u306e\u5834\u5408\u3001\u691c\u51fa\u304c\u96e3\u3057\u3044\u3001\u307e\u305f\u306f\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u5e72\u6e09\u304c\u3042\u308b\u3068\u3001\u691c\u91cf\u7dda\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"916\" height=\"560\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-03.bmp\" alt=\"\" class=\"wp-image-15165\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-03.bmp 916w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-03-300x183.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-03-768x470.jpg 768w\" sizes=\"auto, (max-width: 916px) 100vw, 916px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u304c\u9ad8\u6fc3\u5ea6\u306e\u5834\u5408\u3001\u691c\u51fa\u5668\u304c\u904e\u8ca0\u8377\u306e\u72b6\u614b\u306b\u306a\u308b\u3068\u3001\u691c\u91cf\u7dda\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"916\" height=\"560\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-04.bmp\" alt=\"\" class=\"wp-image-15171\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-04.bmp 916w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-04-300x183.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-3-04-768x470.jpg 768w\" sizes=\"auto, (max-width: 916px) 100vw, 916px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">4\uff0e\u03b2\u5024\uff08\u76f8\u6bd4\uff09\u3092\u6d3b\u7528\u3057\u305f\u30ab\u30e9\u30e0\u9078\u629e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7b2c1\u56de\u3067\u3082\u89e6\u308c\u305f\u3001\u30ab\u30e9\u30e0\u306e\u5185\u5f84\u3068\u819c\u539a\u306e\u6bd4\u7387\u3092\u793a\u3059<strong>\u03b2\u5024\uff08\u76f8\u6bd4\uff09<\/strong>\u306f\u3001\u30ab\u30e9\u30e0\u304c\u63ee\u767a\u6027\u307e\u305f\u306f\u534a\u63ee\u767a\u6027\u306e\u3044\u305a\u308c\u306b\u9069\u3057\u3066\u3044\u308b\u30ab\u30e9\u30e0\u304b\u3092\u5224\u65ad\u3059\u308b\u969b\u3084\u3001\u56fa\u5b9a\u76f8\u306f\u540c\u3058\u3067\u5185\u5f84\u304c\u7570\u306a\u308b\u30ab\u30e9\u30e0\u9593\u3067\u4fdd\u6301\u6642\u9593\u3084\u6eb6\u51fa\u9806\u3092\u985e\u4f3c\u3055\u305b\u308b\u305f\u3081\u306b\u4f7f\u308f\u308c\u308b\u6307\u6a19\u3067\u3059\u3002\u4f8b\u3048\u3070\u300130 m\u00d70.53 mm ID\u00d71.0 \u00b5m\u819c\u539a\u306e\u30ab\u30e9\u30e0\uff08\u03b2=128\uff09\u304b\u3089\u300130 m\u00d70.25 mm ID\u00d70.5 \u00b5m\u819c\u539a\uff08\u03b2=125\uff09\u306b\u5207\u308a\u66ff\u3048\u308b\u969b\u3001\u30ab\u30e9\u30e0\u5bb9\u91cf\u304c\u9069\u5207\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3001\u03b2\u5024\u3092\u57fa\u6e96\u306b\u9078\u629e\u3059\u308c\u3070\u3001\u5206\u6790\u6761\u4ef6\u306e\u5927\u5e45\u306a\u5909\u66f4\u3092\u907f\u3051\u3089\u308c\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d41\u91cf\u3084\u691c\u51fa\u5668\u306e\u30ac\u30b9\uff08\u7279\u306b\u30e1\u30a4\u30af\u30a2\u30c3\u30d7\u30ac\u30b9\uff09\u6d41\u91cf\u3001\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u8abf\u6574\u3082\u5fc5\u8981\u3068\u306a\u308b\u305f\u3081\u3001\u7dcf\u5408\u7684\u306a\u6761\u4ef6\u6700\u9069\u5316\u306f\u91cd\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" rel=\"noreferrer noopener\">\u7b2c1\u56de<\/a>\u3001<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4704-ja\/how-to-choose-the-correct-gc-column-part-2-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4704-ja\/how-to-choose-the-correct-gc-column-part-2-japan\" rel=\"noreferrer noopener\">\u7b2c2\u56de<\/a>\u305d\u3057\u3066\u3053\u306e\u7b2c3\u56de\u3067\u4f7f\u3046\u3079\u304d\u30ab\u30e9\u30e0\u9078\u629e\u80a2\u306e\u7d5e\u308a\u8fbc\u307f\u304c\u3067\u304d\u305f\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\uff1f\u3082\u3057\u307e\u3060\u60c5\u5831\u304c\u8db3\u308a\u306a\u3044\u3068\u611f\u3058\u3066\u3044\u308b\u3088\u3046\u3067\u3057\u305f\u3089<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4706-ja\/how-to-choose-the-correct-gc-column-part-4-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4706-ja\/how-to-choose-the-correct-gc-column-part-4-japan\" rel=\"noreferrer noopener\">\u7b2c4\u56de<\/a>\u3067\u3055\u3089\u306a\u308b\u60c5\u5831\u3092\u898b\u3064\u3051\u3066\u4e0b\u3055\u3044\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u304a\u8aad\u307f\u3044\u305f\u3060\u304d\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u7b2c3\u56de\u306f\u3001\u30ab\u30e9\u30e0\u5bb9\u91cf\uff08\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\uff09\u3001\u691c\u51fa\u5668\u306e\u611f\u5ea6\u7279\u6027\u3068\u76f4\u7dda\u6027\u306b\u6ce8\u76ee\u3002\u5185\u5f84\u3084\u819c\u539a\u306b\u3088\u308b\u5bb9\u91cf\u8abf\u6574\u306e\u30dd\u30a4\u30f3\u30c8\u3001FID\u3084TCD\u306a\u3069\u4e3b\u8981\u691c\u51fa\u5668\u306e\u7279\u6027\u3001\u6700\u9069\u306a\u7d44\u307f\u5408\u308f\u305b\u306b\u3088\u308b\u9ad8\u7cbe\u5ea6\u306a\u5b9a\u91cf\u5206\u6790\u306e\u30b3\u30c4\u3092\u5c02\u9580\u5bb6\u304c\u89e3\u8aac\u3002\u5206\u96e2\u6027\u80fd\u3068\u5b9a\u91cf\u6027\u3092\u4e21\u7acb\u3059\u308b\u5b9f\u8df5\u30ac\u30a4\u30c9\u3067\u3059\u3002<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[2802],"product-library":[],"resource-technique":[2340],"ppma_author":[2823],"class_list":["post-48535","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-type-selection-guides","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-type":[{"value":2802,"label":"Selection Guides"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/ja\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48535","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48535"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48535\/revisions"}],"predecessor-version":[{"id":83677,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48535\/revisions\/83677"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48535"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48535"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48535"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48535"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48535"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48535"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48535"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48535"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48535"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}