{"id":48536,"date":"2012-08-13T14:30:00","date_gmt":"2012-08-13T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/how-to-choose-the-correct-gc-column-part-4-japan\/"},"modified":"2026-01-21T18:21:05","modified_gmt":"2026-01-21T18:21:05","slug":"how-to-choose-the-correct-gc-column-part-4-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4706-ja\/how-to-choose-the-correct-gc-column-part-4-japan","title":{"rendered":"GC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3\u3010\u7b2c4\u56de\u30113\u3064\u306e\u7279\u6b8a\u30b5\u30f3\u30d7\u30eb\u3078\u306e\u5bfe\u5fdc"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u7b2c1\u56de\u304b\u3089\u7b2c3\u56de\uff08\u4ee5\u4e0b\u306e\u30ea\u30f3\u30af\u304b\u3089\u3082\u30a2\u30af\u30bb\u30b9\u3067\u304d\u307e\u3059\uff09\u307e\u3067\u3067\u898b\u3066\u304d\u305f\u306e\u306f\u3001\u30ab\u30e9\u30e0\u9078\u629e\u306e\u4e00\u822c\u7684\u306a\u30d7\u30ed\u30bb\u30b9\u3067\u3057\u305f\u3002\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u629e\u306e\u790e\u304c\u3067\u304d\u305f\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4703-ja\/how-to-choose-the-correct-gc-column-part-1-japan\" rel=\"noreferrer noopener\">GC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3 \u00a0\u7b2c1\u56de\uff1a\u6cb8\u70b9\u304b\u3089\u59cb\u3081\u308b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u3073<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4704-ja\/how-to-choose-the-correct-gc-column-part-2-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4704-ja\/how-to-choose-the-correct-gc-column-part-2-japan\" rel=\"noreferrer noopener\">GC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3\u00a0 \u7b2c2\u56de\uff1a\u30ab\u30e9\u30e0\u9078\u3073\u306b\u6b20\u304b\u305b\u306a\u3044\u8996\u70b9\u3001\u6975\u6027<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4705-ja\/how-to-choose-the-correct-gc-column-part-3-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4705-ja\/how-to-choose-the-correct-gc-column-part-3-japan\" rel=\"noreferrer noopener\">GC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3\u00a0 \u7b2c3\u56de\uff1a\u30ab\u30e9\u30e0\u5bb9\u91cf\u304a\u3088\u3073\u691c\u51fa\u5668\u306e\u611f\u5ea6\u7279\u6027\u3068\u76f4\u7dda\u6027<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u7d42\u56de\u306e\u7b2c4\u56de\u3067\u306fGC\u5206\u6790\u306e\u96e3\u6613\u5ea6\u304c\u98db\u8e8d\u7684\u306b\u4e0a\u304c\u308b\u7279\u6b8a\u306a\u30b5\u30f3\u30d7\u30eb\u3078\u306e\u5bfe\u5fdc\u306b\u3064\u3044\u3066\u30013\u3064\u306e\u30b1\u30fc\u30b9\u306b\u5206\u3051\u3066\u8a73\u8aac\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">1\uff0e\u30ac\u30b9\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u3092\u4f7f\u7528\u3057\u305f\u5206\u6790<\/h2>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"200\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-4-01.jpg\" alt=\"\" class=\"wp-image-15177\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-4-01.jpg 200w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-4-01-150x150.jpg 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30b9\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u306e\u5199\u771f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u3001\u30b5\u30f3\u30d7\u30eb\u5c0e\u5165\u306b\u30ac\u30b9\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u3092\u4f7f\u7528\u3059\u308b\u5206\u6790\u3067\u306e\u3001\u9069\u5207\u306a\u30ab\u30e9\u30e0<strong>\u5185\u5f84\uff08ID\uff09<\/strong>\u306e\u9078\u5b9a\u65b9\u6cd5\u3067\u3059\u3002\u3053\u3053\u3067\u8aac\u660e\u3059\u308b\u306e\u306f\u3001\u4e0b\u8a18\u306e\u3088\u3046\u306a\u30de\u30eb\u30c1\u30dd\u30fc\u30c8\u30ac\u30b9\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u30d0\u30eb\u30d6\u3092\u4f7f\u7528\u3059\u308b\u5727\u529b\u30eb\u30fc\u30d7\u30b7\u30b9\u30c6\u30e0\u306e\u5834\u5408\u3067\u3059\u3002\u3053\u306e\u5727\u529b\u30eb\u30fc\u30d7\u30b7\u30b9\u30c6\u30e0\u306f\u3001\u5929\u7136\u30ac\u30b9\u5206\u6790\u3084\u6e29\u5ba4\u52b9\u679c\u30ac\u30b9\u5206\u6790\u3067\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"200\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-4-02.jpg\" alt=\"\" class=\"wp-image-15183\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-4-02.jpg 200w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-4-02-150x150.jpg 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">6\u30dd\u30fc\u30c8\u30ac\u30b9\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u30d0\u30eb\u30d6\u306e\u5199\u771f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u3092\u9069\u5ea6\u306b\u30b7\u30e3\u30fc\u30d7\u306b\u4fdd\u3064\u305f\u3081\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u306e\u4f53\u7a4d\uff08mL\uff09\u306f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u91cf\uff08mL\/min\uff09\u306e1\/10\u3092\u8d85\u3048\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u3001\u3068\u3044\u3046\u306e\u304c\u7d4c\u9a13\u5247\u3067\u3059\u3002\u4f8b\u3048\u3070\u30011 mL\u306e\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u3092\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u304c\u904e\u5ea6\u306b\u30d6\u30ed\u30fc\u30c9\u306b\u306a\u308a\u3059\u304e\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u305f\u3081\u306b\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u91cf\u3092\u5c11\u306a\u304f\u3068\u308210 mL\/min\u306b\u8a2d\u5b9a\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\uffe5\u3002\u3053\u308c\u306f\u30011\/16\u30a4\u30f3\u30c1OD\uff081mm ID\uff09\u306e\u30de\u30a4\u30af\u30ed\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u4e00\u822c\u7684\u306a\u6d41\u91cf\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;\u9006\u306b\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u91cf\u304c1 mL\/min\u3067\u30010.25 mm ID\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u3001\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u4f53\u7a4d\u306f0.1 mL\uff08\u307e\u305f\u306f100 \u00b5L\uff09\u3092\u8d85\u3048\u306a\u3044\u3088\u3046\u306b\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u8a18\u306e\u7d4c\u9a13\u5247\u306b\u95a2\u3057\u3066\u306f\u3001\u4ee5\u4e0b\u306e\u70b9\u3092\u7559\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1.&nbsp; \u30ac\u30b9\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u306b\u306e\u307f\u9069\u7528\u3055\u308c\u307e\u3059\u3002\u30ac\u30b9\u30bf\u30a4\u30c8\u30b7\u30ea\u30f3\u30b8\u306b\u306f\u8a72\u5f53\u3057\u307e\u305b\u3093\u3002\u306a\u305c\u306a\u3089\u30ac\u30b9\u30bf\u30a4\u30c8\u30b7\u30ea\u30f3\u30b8\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u3088\u308a\u3082\u8fc5\u901f\u306b\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3067\u304d\u308b\u305f\u3081\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2.&nbsp; \u5316\u5408\u7269\u304c\u30ab\u30e9\u30e0\u3084\u88c5\u7f6e\u5185\u3067\u51b7\u5374\u3055\u308c\u3066\u518d\u30d5\u30a9\u30fc\u30ab\u30b9\u3055\u308c\u306a\u3044\u5834\u5408\u306b\u306e\u307f\u5f53\u3066\u306f\u307e\u308a\u307e\u3059\u3002\u4e00\u65b9\u3067\u3001\u5316\u5408\u7269\u304c\u30ab\u30e9\u30e0\u5148\u7aef\u3067\u30c8\u30e9\u30c3\u30d7\u3055\u308c\u3001\u72ed\u3044\u30d0\u30f3\u30c9\u3068\u3057\u3066\u518d\u5ea6\u96c6\u3081\u3089\u308c\u308b\u5834\u5408\u306f\u3001\u3088\u308a\u591a\u304f\u306e\u30ac\u30b9\u91cf\u3092\u6ce8\u5165\u3057\u3066\u3082\u30d4\u30fc\u30af\u304c\u5e83\u304c\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">3.&nbsp; \u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u4f53\u7a4d\u3068\u30b5\u30f3\u30d7\u30eb\u6fc3\u5ea6\u3092\u6df7\u540c\u3057\u306a\u3044\u3088\u3046\u306b\u6ce8\u610f\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u4e0a\u8a18\u306e\u7d4c\u9a13\u5247\u306f\u3042\u304f\u307e\u3067\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u4f53\u7a4d\u306b\u3064\u3044\u3066\u8ff0\u3079\u305f\u3082\u306e\u3067\u3042\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u5316\u5408\u7269\u306e\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u306f\u89e6\u308c\u3066\u3044\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">4.&nbsp; \u4e00\u822c\u7684\u306b\u3001\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u4f53\u7a4d\u304c\u5c0f\u3055\u3044\u307b\u3069\u3001\u30d4\u30fc\u30af\u306f\u30b7\u30e3\u30fc\u30d7\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">2\uff0e\u9178\u6027\/\u5869\u57fa\u6027\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001\u9178\u6027\uff08\u304a\u3088\u3073\u4e2d\u6027\uff09\u307e\u305f\u306f\u5869\u57fa\u6027\uff08\u304a\u3088\u3073\u4e2d\u6027\uff09\u306e\u5316\u5408\u7269<strong>\u306e\u307f<\/strong>\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002\u9178\u6027\u307e\u305f\u306f\u5869\u57fa\u6027\u306e\u6db2\u76f8\u3084\u5145\u586b\u7269\u3092\u542b\u3080\u30ab\u30e9\u30e0\u3092\u4f7f\u3048\u3070\u3001\u3088\u308a\u826f\u3044\u30d4\u30fc\u30af\u5f62\u72b6\uff08\u30c6\u30fc\u30ea\u30f3\u30b0\u304c\u6291\u3048\u3089\u308c\u305f\uff09\u304c\u5f97\u3089\u308c\u308b\u305f\u3081\u3001\u5316\u5408\u7269\u306e\u691c\u51fa\u611f\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<strong>\u30ab\u30e9\u30e0\u306e\u640d\u50b7\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u306b\u3001\u6ce8\u610f\u304c\u5fc5\u8981\u306a\u306e\u306f\u3001\u6ce8\u5165\u30b5\u30f3\u30d7\u30eb\u306epH\u3067\u3059\u3002\u4e00\u822c\u7684\u306a\u30ab\u30e9\u30e0\u3067\u306fpH &nbsp;5\uff5e9\u3001\u9178\u6027\u30ab\u30e9\u30e0\u3067\u306fpH &nbsp;5\uff5e7\u3001\u5869\u57fa\u6027\u30ab\u30e9\u30e0\u3067\u306fpH &nbsp;7\uff5e9\u306b\u4fdd\u3061\u307e\u3057\u3087\u3046\u3002<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u7684\u306a<strong>\u9178\u6027<\/strong>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1726\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax-DA<\/a>\uff08\u5145\u586b\u30ab\u30e9\u30e0\u306e\u6db2\u76f8FFAP\u306b\u985e\u4f3c\uff09\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305d\u306e\u4ed6\u306e\u9178\u6027\u5145\u586b\u7269\u306b\u306f\u3001\u5c11\u91cf\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/search?Ntt=H3PO4&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\">H3PO4<\/a>\u304a\u3088\u3073\/\u307e\u305f\u306f<a href=\"https:\/\/www.restek.com\/global\/ja\/search?Ntt=CarboBlack+B-DA&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\">CarboBlack B-DA<\/a>\u3092\u542b\u3080\u56fa\u4f53\u652f\u6301\u4f53\u304c\u542b\u307e\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u822c\u7684\u306a<strong>\u5869\u57fa\u6027<\/strong>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u306f\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1727\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax-DB<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1690\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-5 Amine<\/a>\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1694\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-35 Amine<\/a>\u3001\u304a\u3088\u3073<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1718\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-Volatile Amine<\/a>\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5869\u57fa\u6027\u5145\u586b\u7269\u306b\u306f\u3001\u5c11\u91cf\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/search?Ntt=KOH&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\">KOH<\/a>\u307e\u305f\u306f<a href=\"https:\/\/www.restek.com\/global\/ja\/search?Ntt=HayeSep&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\">HayeSep<\/a> B\u3092\u542b\u3080\u652f\u6301\u4f53\u304c\u542b\u307e\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">3\uff0e\u53cd\u5fdc\u6027\u306e\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u5f8c\u306b\u3001\u975e\u5e38\u306b\u53cd\u5fdc\u6027\u306e\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\uff08\u5f37\u9178\u6027\u307e\u305f\u306f\u5f37\u5869\u57fa\u6027\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u542b\u3080\uff09\u306e\u5206\u6790\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002\u53cd\u5fdc\u6027\u306e\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u3084\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u3092\u640d\u50b7\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u8010\u4e45\u6027\u304c\u9ad8\u3044\u3001\u4ee5\u4e0b\u306e2\u7a2e\u985e\u306e\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u3092\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/80127-800\" target=\"_blank\" rel=\"noreferrer noopener\">5% Krytox on CarboBlack B in Nickel or Hastelloy tubing<\/a>.&nbsp; &nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/80465-800\" target=\"_blank\" rel=\"noreferrer noopener\">Chromosorb T in PTFE or Nickel or Hastelloy tubing<\/a>.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"174\" height=\"100\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-how-to-choose-the-correct-gc-column-part-4-03.jpg\" alt=\"\" class=\"wp-image-15189\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u3082\u3057\u3053\u308c\u3089\u306e\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3067\u304d\u305a\u3001<strong>\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc<\/strong>\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u5834\u5408\u306f\u3001\u819c\u539a\u306e\u539a\u3044<a href=\"https:\/\/www.restek.com\/global\/ja\/search?Ntt=Rtx-1&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-1<\/a>\u3092\u8a66\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u306f<a href=\"https:\/\/www.restek.com\/global\/ja\/search?Ntt=WCOT&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\">WCOT<\/a>\uff08\u58c1\u88ab\u8986\u958b\u7ba1\uff09\u30ab\u30e9\u30e0\u306e\u4e2d\u3067\u6700\u3082\u8010\u4e45\u6027\u304c\u9ad8\u3044\u3082\u306e\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306eGC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3 &nbsp;4\u56de\u30b7\u30ea\u30fc\u30ba\u306f\u3001\u7686\u3055\u3093\u306e\u5206\u6790\u306b\u5927\u304d\u306a\u30d2\u30f3\u30c8\u3068\u306a\u3063\u305f\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002\u3053\u3053\u3067\u63d0\u793a\u3067\u304d\u306a\u304b\u3063\u305f\u30b1\u30fc\u30b9\u306b\u5bfe\u3057\u3066\u3082\u3001\u5fdc\u7528\u3067\u304d\u308b\u30a2\u30a4\u30c7\u30a2\u304c\u6e80\u8f09\u3060\u3063\u305f\u3068\u4fe1\u3058\u3066\u3044\u307e\u3059\uff01<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u6700\u7d42\u56de\u3067\u306f\u3001\u30ac\u30b9\u30b5\u30f3\u30d7\u30eb\u30eb\u30fc\u30d7\u3001\u9178\u6027\u30fb\u5869\u57fa\u6027\u30b5\u30f3\u30d7\u30eb\u3001\u8d85\u53cd\u5fdc\u6027\u30b5\u30f3\u30d7\u30eb\u306a\u3069\u7279\u6b8a\u30b5\u30f3\u30d7\u30eb\u3078\u306e\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u5b9a\u6cd5\u3092\u89e3\u8aac\u3002\u30ab\u30e9\u30e0\u5bff\u547d\u3092\u5ef6\u3070\u3059\u305f\u3081\u306e\u5177\u4f53\u7b56\u3084\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30fb\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306e\u4f7f\u3044\u5206\u3051\u3001\u30c8\u30e9\u30d6\u30eb\u4e88\u9632\u7b56\u3082\u7d39\u4ecb\u3002\u73fe\u5834\u3067\u5f79\u7acb\u3064\u5b9f\u8df5\u30ac\u30a4\u30c9\u3067\u3059\u3002<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[2823],"class_list":["post-48536","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/ja\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48536","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48536"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48536\/revisions"}],"predecessor-version":[{"id":83678,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48536\/revisions\/83678"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48536"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48536"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48536"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48536"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48536"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48536"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48536"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48536"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48536"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}