{"id":48537,"date":"2012-02-29T13:30:00","date_gmt":"2012-02-29T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-can-i-analyze-no-n2o-and-no2-via-gc\/"},"modified":"2025-11-25T17:29:57","modified_gmt":"2025-11-25T17:29:57","slug":"japanese-can-i-analyze-no-n2o-and-no2-via-gc","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4595-ja\/japanese-can-i-analyze-no-n2o-and-no2-via-gc","title":{"rendered":"GC\u3067NO\u3001N2O \u3001NO2 \u306f\u5206\u6790\u3067\u304d\u307e\u3059\u304b?"},"content":{"rendered":"\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-can-i-analyze-no-n2o-and-no2-via-gc-01.jpg\" alt=\"2011-jaap-pasfoto4\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u8cea\u554f\u306f\u6bce\u5e74\u4f55\u56de\u3082\u805e\u304b\u308c\u307e\u3059\u3002\u6614Chrompack\u793e\u3067\u4e00\u7dd2\u306b\u50cd\u3044\u3066\u3044\u305f Dick Zwiep \u306f\u3053\u306e\u8cea\u554f\u306b\u3001&nbsp;<em><strong>No \u3001 No-two!<\/strong><\/em>\u3068\u5197\u8ac7\u307e\u3058\u308a\u306b\u7b54\u3048\u3066\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u554f\u984c\u306fN2O\u3067\u306f\u306a\u304f\u3001NO \u3068 NO2\u3067\u3059\u3002NO \u3068 NO2 \u306f\u53cd\u5fdc\u3057\u3084\u3059\u304b\u3063\u305f\u308a\u5e73\u8861\u72b6\u614b\u306b\u3042\u308b\u305f\u3081\u3001\u5b9a\u91cf\u306f\u56f0\u96e3\u3067\u3059\u3002<em><strong><\/strong><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>N2O(\u4e9c\u9178\u5316\u7a92\u7d20)<\/strong>\u306f\u201d\u7b11\u6c17\u30ac\u30b9\u201d\u3068\u3082\u547c\u3070\u308c\u3001GC\u3067\u5206\u6790\u3059\u308b\u306e\u306f\u3068\u3066\u3082\u7c21\u5358\u3067\u3059\u3002 Rt Q-BOND\u306e\u3088\u3046\u306a\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u30bf\u30a4\u30d7\u306e\u56fa\u5b9a\u76f8\u3092\u7528\u3044\u3066\u5206\u6790\u3067\u304d\u307e\u3059(\u56f31. \u53c2\u7167)\u3002 N2O\u306e\u6eb6\u51fa\u306f\u304b\u306a\u308a\u65e9\u3044\u306e\u3067\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u304c\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306f\u691c\u51fa\u5668\u306bMS\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u5185\u5f84 0.25mm\u306e PLOT \u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002 N2O \u306e\u691c\u51fa\u306b\u306fECD\u3082\u3088\u304f\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-can-i-analyze-no-n2o-and-no2-via-gc-02.gif\" alt=\"decorative\" class=\"wp-image-4584\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u56f31. \u4e9c\u9178\u5316\u7a92\u7d20\u306e\u30d4\u30fc\u30af\u306f Rt-Q-BOND\u306e\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u304b\u3089\u5bfe\u79f0\u306a\u30d4\u30fc\u30af\u3068\u3057\u3066\u6eb6\u51fa\u3057\u3066\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>NO(\u4e00\u9178\u5316\u7a92\u7d20)<\/strong>\u306e\u6e2c\u5b9a\u306f\u304b\u306a\u308a\u56f0\u96e3\u3067\u3059\u3002\u9178\u7d20\u306b\u89e6\u308c\u308b\u3068\u3001&nbsp;NO\u306f\u8d64\u8910\u8272\u306eNO2 (\u4e8c\u9178\u5316\u7a92\u7d20)\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2 NO + O<sub>2<\/sub>&nbsp;\u2192 2 NO<sub>2<\/sub><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u304c\u3053\u306e\u6e2c\u5b9a\u306e\u8ab2\u984c\u306e\u4e00\u3064\u3067\u3059\u3002NO\u306fO2\u3068\u76f4\u3061\u306b\u53cd\u5fdc\u3057\u307e\u3059\u3002 O2\u304c\u5b58\u5728\u3057\u306a\u3044\u5834\u5408\u306f\u3001NO\u306f\u307b\u3068\u3093\u3069\u306e\u30ab\u30e9\u30e0\u304b\u3089\u6eb6\u51fa\u3057\u3066\u304d\u307e\u3059\u304c\u3001\u4fdd\u6301\u306f\u6975\u3081\u3066\u5f31\u3044\u3082\u306e\u3067\u3059\u3002\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u30bf\u30a4\u30d7\u306e\u56fa\u5b9a\u76f8\u3067\u3055\u3048\u3001\u6c38\u4e45\u30ac\u30b9\u3068\u5171\u6eb6\u51fa\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">NO\u306f\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\u30bf\u30a4\u30d7\u306e\u5438\u7740\u5264\u306b\u4fdd\u6301\u3055\u308c\u3001\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306f\u901a\u5e38\u5bfe\u79f0\u3067\u306f\u306a\u304f\u3001\u4f4e\u6fc3\u5ea6\u306e\u6e2c\u5b9a\u306f\u56f0\u96e3\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">NO\/NO2 \u306e\u53cd\u5fdc\u901f\u5ea6\u8ad6\u306e\u30e2\u30c7\u30eb\u306b\u3064\u3044\u3066\u306f\u3001\u4e0b\u8a18\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\uff1a<a href=\"http:\/\/www.chem.tamu.edu\/rgroup\/hughbanks\/courses\/102H\/lecturenotes\/class12-1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">http:\/\/www.chem.tamu.edu\/rgroup\/hughbanks\/courses\/102H\/lecturenotes\/class12-1.pdf<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>NO2 (\u4e8c\u9178\u5316\u7a92\u7d20)<\/strong>&nbsp;\u306fGC\u3067\u5206\u6790\u3059\u308b\u306e\u304c\u6700\u3082\u56f0\u96e3\u3067\u3059\u3002 NO<sub>2<\/sub>&nbsp;\u306fN<sub>2<\/sub>O<sub>4<\/sub>(\u56db\u9178\u5316\u4e8c\u7a92\u7d20)\u3068\u5e73\u8861\u72b6\u614b\u3067\u5b58\u5728\u3057\u307e\u3059:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2 NO<sub>2<\/sub>&nbsp;&lt;=&gt;&nbsp;&nbsp;&nbsp;&nbsp; N<sub>2<\/sub>O<sub>4<\/sub><\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-can-i-analyze-no-n2o-and-no2-via-gc-03.gif\" alt=\"decorative\" class=\"wp-image-4585\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><sub>\u56f32. \u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\u30d9\u30fc\u30b9\u306e\u591a\u5b54\u8cea\u30dd\u30ea\u30de\u30fc\u306eNO2\u3068\u306e\u53cd\u5fdc\u306b\u3088\u308a\u5b9a\u91cf\u306f\u56f0\u96e3\u306b\u306a\u308a\u307e\u3059\u3002<\/sub><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u5206\u6790\u306b\u306f\u3044\u304f\u3064\u304b\u306e\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u304c\u3042\u308a\u307e\u3059\u3002\u6700\u3082\u308f\u304b\u308a\u3084\u3059\u3044\u3082\u306e\u306f\u591a\u5b54\u8cea\u30dd\u30ea\u30de\u30fc\u3092\u4f7f\u7528\u3057\u305f\u3082\u306e\u3067\u3059\u304c\u3001\u4e8c\u9178\u5316\u7a92\u7d20\u306f\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u3068\u53cd\u5fdc\u3057\u3066\u30a8\u30c1\u30ec\u30f3\u30d4\u30fc\u30af\u3092\u5f62\u6210\u3057\u307e\u3059(\u56f32.) \u3002\u3053\u308c\u306f\u5165\u308a\u53e3\u90e8\u5206\u306e\u71b1\u3067 NO2\u3092\u30a8\u30c1\u30ec\u30f3\u306b\u5909\u63db\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u9593\u63a5\u7684\u306b NO2 \u3092\u6e2c\u5b9a\u3059\u308b\u65b9\u6cd5\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u304c\u3001\u5909\u63db\u306f\u5b9a\u91cf\u7684\u3067\u306f\u306a\u3044\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">NO2 \u5206\u6790\u306b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u306f\u30b7\u30ea\u30ab\u30b2\u30eb\u306b\u306a\u308b\u3068\u63a8\u6e2c\u3067\u304d\u307e\u3059\u304c\u3001\u30c7\u30fc\u30bf\u306f\u9650\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f4e\u6fc3\u5ea6\u306e\u691c\u51fa\u306b\u306fMS\u3001ECD\u304a\u3088\u3073PDD\u3092\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002TCD\u3067\u3082\u691c\u51fa\u306f\u53ef\u80fd\u3067\u3059\u304c\u3001ppm\u30ec\u30d9\u30eb\u306e\u6e2c\u5b9a\u306e\u307f\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The original entry of this blog was posted on Thursday, March 1st,2012 at 10:10 am and is filed under Optimizing Applications.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This question pops up a number of times every year. The joking answer my former colleague Dick Zwiep (when we both worked at Chrompack time) used to make was: No and No-two! The challenge is not the N2O, but the&#8230;<\/p>\n","protected":false},"author":19,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[439],"class_list":["post-48537","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jaap de Zeeuw","author_link":"https:\/\/discover.restek.com\/ja\/author\/jaap-de-zeeuw\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":439,"user_id":19,"is_guest":0,"slug":"jaap-de-zeeuw","display_name":"Jaap de Zeeuw","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg"},"author_category":"1","first_name":"Jaap","last_name":"de Zeeuw","user_url":"https:\/\/www.linkedin.com\/in\/jaap-de-zeeuw-ba102a7\/","job_title":"GC Consultant","description":"Jaap is a world-renowned chromatographer with over 40 years of experience, including 15 years with Restek and 27 years with Varian\/Chrompack prior to joining Restek. Throughout his career, Jaap has focused the chromatographic challenges of industrial analysis. For his 1979 graduation from The Institute for Higher Education, where he specialized in chemistry, Jaap authored a paper titled \"The Challenge of Coating Flexible Fused Silica Capillary Columns\" and has since distinguished himself as an authority on the subject. Jaap has been directly involved with the creation of numerous chemically bonded columns, including the first bonded PEG column and the stabilized PLOT columns widely used in the petrochemical arena. He has also helped develop new techniques, such as fast GC-MS using vacuum GC technology (low-pressure GC or LPGC). Over his innovative career, he has filed several patents for his work. Based out of the Netherlands, Jaap is extensively published and regularly travels internationally to share his knowledge. After retiring from Restek, Jaap founded CreaVisions, where he works as a GC Consultant and teaches master classes on key GC topics as well as on creativity in science."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48537","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48537"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48537\/revisions"}],"predecessor-version":[{"id":68849,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48537\/revisions\/68849"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48537"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48537"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48537"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48537"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48537"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48537"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48537"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48537"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48537"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}