{"id":48538,"date":"2016-04-17T14:30:00","date_gmt":"2016-04-17T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-analysis-of-n2o-nitrous-oxide-via-gc-an-update\/"},"modified":"2025-11-13T20:39:25","modified_gmt":"2025-11-13T20:39:25","slug":"japanese-analysis-of-n2o-nitrous-oxide-via-gc-an-update","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4576-ja\/japanese-analysis-of-n2o-nitrous-oxide-via-gc-an-update","title":{"rendered":"GC\u306b\u3088\u308bN2O (\u4e9c\u9178\u5316\u7a92\u7d20) \u306e\u5206\u6790: \u66f4\u65b0"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u4e9c\u9178\u5316\u7a92\u7d20(N2O)\u306f\u4e00\u822c\u306b\u201d\u7b11\u6c17\u30ac\u30b9\u201d\u3068\u3057\u3066\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30ed\u30b1\u30c3\u30c8\u71c3\u6599\u3084\u30a8\u30a2\u30be\u30fc\u30eb\u30ac\u30b9\u3068\u3057\u3066\u3082\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002 N2O\u81ea\u4f53\u306f\u5b89\u5b9a\u306a\u30ac\u30b9\u3067\u3042\u308a\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3092\u7528\u3044\u3066\u6bd4\u8f03\u7684\u7c21\u5358\u306b\u5206\u6790\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002N2O\u306f\u3088\u304fNO(\u4e00\u9178\u5316\u7a92\u7d20)\u3068\u6df7\u540c\u3055\u308c\u307e\u3059\u3002 NO\u306f\u975e\u5e38\u306b\u53cd\u5fdc\u6027\u306e\u9ad8\u3044\u30ac\u30b9\u3067\u3059\u3002\u9178\u7d20\u5b58\u5728\u4e0b\u3067\u306f\u3001NO\u306f\u3059\u3050\u306b\u9178\u5316\u3055\u308c\u3066NO2\u306b\u306a\u308a\u307e\u3059\u3002 NO2\u306f\u8d64\u8910\u8272\u3092\u793a\u3059\u305f\u3081\u3001\u7c21\u5358\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001NO2\u306f\u53cd\u5fdc\u6027\u3092\u793a\u3057\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3088\u308bNO\u304a\u3088\u3073 NO2\u306e\u5206\u6790\u306f\u4e00\u822c\u306b\u306f\u304a\u3053\u306a\u308f\u308c\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"450\" height=\"760\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analysis-of-n2o-nitrous-oxide-via-gc-an-update-02.jpg\" alt=\"\" class=\"wp-image-12664\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analysis-of-n2o-nitrous-oxide-via-gc-an-update-02.jpg 450w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-analysis-of-n2o-nitrous-oxide-via-gc-an-update-02-178x300.jpg 178w\" sizes=\"auto, (max-width: 450px) 100vw, 450px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Nitrous oxide on Alumina BOND \/ Na2SO4 Column: 30m x 0.53mm Rt Alumina BOND \/ Na2SO4; Helium, 4 mL\/min; Oven: 40\u00baC; sample: 60\u00b5l; Detector: PlasmaDetek PED; sample: 5.4 ppm N2O.Chromatogram courtesy: L. Paradis, LDetec.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8fd1\u3001\u30bb\u30d1\u30ec\u30fc\u30b7\u30e7\u30f3\u30fb\u30b5\u30a4\u30a8\u30f3\u30b9\u3067 N2O\u5206\u6790\u306b\u95a2\u3059\u308b\u30b5\u30de\u30ea\u30fc\u306e\u767a\u8868\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u591a\u5b54\u8cea\u30dd\u30ea\u30de\u30fc\u3084 \u30a2\u30eb\u30df\u30ca\u3001Molesieve 5A\u304a\u3088\u3073ShinCarbon\u306a\u3069\u7570\u306a\u308b\u56fa\u5b9a\u76f8\u306b\u304a\u3051\u308b\u5206\u96e2\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">CO2\u304c\u5b58\u5728\u3059\u308b\u3068N2O\u306e\u6e2c\u5b9a\u306e\u59a8\u3052\u306b\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u30a2\u30eb\u30df\u30caPLOT\u306b\u3088\u308b\u5206\u6790\u306f\u3068\u308a\u308f\u3051\u8208\u5473\u6df1\u3044\u3082\u306e\u306b\u306a\u3063\u3066\u3044\u307e\u3059(\u56f31.) \u3002 CO2\u306f\u30a2\u30eb\u30df\u30ca\u306b\u3088\u3063\u3066\u5b8c\u5168\u306b\u5438\u7740\u3055\u308c\u3001\u305d\u306e\u7d50\u679c N2O\u306e\u5358\u4e00\u306a\u30d4\u30fc\u30af\u304c\u5f97\u3089\u308c\u307e\u3059\u3002CO2\u306f\u5b9a\u671f\u7684\u306b200\u2103\u3067\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u9664\u53bb\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The original entry of this blog was posted on Monday,April 18th,2016 at 8:16 am and is filed under Miscellaneous.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u4e9c\u9178\u5316\u7a92\u7d20 (N2O)\u306f\u4e00\u822c\u306b\u300c\u7b11\u6c17\u30ac\u30b9\u300d\u3068\u3057\u3066\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30ed\u30b1\u30c3\u30c8\u71c3\u6599\u306e\u6210\u5206\u3084\u30a8\u30a2\u30ed\u30be\u30fc\u30eb\u5674\u5c04\u5264\u3068\u3057\u3066\u3082\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002N2O\u81ea\u4f53\u306f\u5b89\u5b9a\u306a\u30ac\u30b9\u3067\u3001\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u6bd4\u8f03\u7684\u7c21\u5358\u306b\u5206\u6790\u3067\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"author":19,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[2270,2265,2284],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[439],"class_list":["post-48538","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","industries-application-energy-ja","industries-application-chemical-production-ja","industries-application-fuel-production-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"industries-application":[{"value":2270,"label":"\u30a8\u30cd\u30eb\u30ae\u30fc"},{"value":2265,"label":"\u5316\u5b66\u88fd\u54c1\u88fd\u9020"},{"value":2284,"label":"\u71c3\u6599\u751f\u7523"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jaap de Zeeuw","author_link":"https:\/\/discover.restek.com\/ja\/author\/jaap-de-zeeuw\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":439,"user_id":19,"is_guest":0,"slug":"jaap-de-zeeuw","display_name":"Jaap de Zeeuw","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-de-zeeuw-jaap.jpg"},"author_category":"1","first_name":"Jaap","last_name":"de Zeeuw","user_url":"https:\/\/www.linkedin.com\/in\/jaap-de-zeeuw-ba102a7\/","job_title":"GC Consultant","description":"Jaap is a world-renowned chromatographer with over 40 years of experience, including 15 years with Restek and 27 years with Varian\/Chrompack prior to joining Restek. Throughout his career, Jaap has focused the chromatographic challenges of industrial analysis. For his 1979 graduation from The Institute for Higher Education, where he specialized in chemistry, Jaap authored a paper titled \"The Challenge of Coating Flexible Fused Silica Capillary Columns\" and has since distinguished himself as an authority on the subject. Jaap has been directly involved with the creation of numerous chemically bonded columns, including the first bonded PEG column and the stabilized PLOT columns widely used in the petrochemical arena. He has also helped develop new techniques, such as fast GC-MS using vacuum GC technology (low-pressure GC or LPGC). Over his innovative career, he has filed several patents for his work. Based out of the Netherlands, Jaap is extensively published and regularly travels internationally to share his knowledge. After retiring from Restek, Jaap founded CreaVisions, where he works as a GC Consultant and teaches master classes on key GC topics as well as on creativity in science."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/19"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48538"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48538\/revisions"}],"predecessor-version":[{"id":64010,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48538\/revisions\/64010"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48538"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48538"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48538"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48538"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48538"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48538"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}