{"id":48539,"date":"2012-11-15T13:30:00","date_gmt":"2012-11-15T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/when-not-to-use-gc-mass-spec-japan\/"},"modified":"2026-01-21T18:24:42","modified_gmt":"2026-01-21T18:24:42","slug":"when-not-to-use-gc-mass-spec-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4864-ja\/when-not-to-use-gc-mass-spec-japan","title":{"rendered":"GC\u5206\u6790\u306e\u6700\u9069\u89e3\uff1a\u30ab\u30e9\u30e0\u3068\u691c\u51fa\u5668\u306e\u9078\u3073\u65b9"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">GC\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u7279\u5b9a\u306e\u5206\u6790\u5bfe\u8c61\u306b\u5bfe\u3057\u3066\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3068\u691c\u51fa\u5668\u306e\u7d44\u307f\u5408\u308f\u305b\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u306f\u3001\u6b63\u78ba\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u3092\u5f97\u308b\u305f\u3081\u306b\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u7279\u306b\u3001\u6c38\u4e45\uff08\u56fa\u5b9a\uff09\u30ac\u30b9\u3001\u8efd\u8cea\u70ad\u5316\u6c34\u7d20\u3001\u9ad8\u6cb8\u70b9\u5316\u5408\u7269\u306a\u3069\u3001\u7279\u6027\u306e\u7570\u306a\u308b\u5316\u5408\u7269\u7fa4\u3092\u5206\u6790\u3059\u308b\u969b\u306b\u306f\u3001\u691c\u51fa\u5668\u306e\u539f\u7406\u3068\u30ab\u30e9\u30e0\u306e\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3068\u306a\u308a\u307e\u3059\u3002\u8a73\u3057\u304f\u89e3\u8aac\u3057\u305f\u4ee5\u524d\u306e\u6295\u7a3f\u3082\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4706-ja\/how-to-choose-the-correct-gc-column-part-4-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4706-ja\/how-to-choose-the-correct-gc-column-part-4-japan\" rel=\"noreferrer noopener\">GC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u6700\u9069\u89e3\u3010\u7b2c3\u56de\u3011\u30ab\u30e9\u30e0\u5bb9\u91cf\u304a\u3088\u3073\u691c\u51fa\u5668\u306e\u611f\u5ea6\u7279\u6027\u3068\u76f4\u7dda\u6027<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">GC\/MS\u306f\u3001\u8907\u96d1\u306a\u6df7\u5408\u7269\u4e2d\u306e\u5fae\u91cf\u6210\u5206\u306e\u540c\u5b9a\u306b\u975e\u5e38\u306b\u6709\u52b9\u306a\u30c4\u30fc\u30eb\u3067\u3059\u304c\u3001\u6c38\u4e45\u30ac\u30b9\uff08\u30d8\u30ea\u30a6\u30e0\u3001\u6c34\u7d20\u3001\u9178\u7d20\u3001\u7a92\u7d20\u3001\u4e00\u9178\u5316\u70ad\u7d20\u306a\u3069\uff09\u306e\u5206\u6790\u306b\u306f\u3044\u304f\u3064\u304b\u306e\u8ab2\u984c\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u308c\u306f\u3001\u6c38\u4e45\u30ac\u30b9\u306e\u5206\u5b50\u91cf\u306e\u5c0f\u3055\u3055\u306b\u8d77\u56e0\u3057\u3066\u5341\u5206\u306a\u611f\u5ea6\u3084\u5206\u96e2\u304c\u5f97\u3089\u308c\u306a\u3044\u3053\u3068\u3084\u3001\u9069\u5207\u306a\u30ab\u30e9\u30e0\u306e\u9078\u629e\u306e\u96e3\u3057\u3055\u306a\u3069\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u8ab2\u984c\u3092\u514b\u670d\u3059\u308b\u305f\u3081\u306b\u3001TCD\u3001HID\u3001DID\u306a\u3069\u306e\u6c4e\u7528\u691c\u51fa\u5668\u304c\u3057\u3070\u3057\u3070\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/blogs\/gnbl5475\/can-i-use-a-gcms-to-analyze-permanent-fixed-gases\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl5475\/can-i-use-a-gcms-to-analyze-permanent-fixed-gases\/\" rel=\"noreferrer noopener\">GC\/MS\u6c38\u4e45\u30ac\u30b9\u5206\u6790\u306b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u629e\u30ac\u30a4\u30c9<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ed6\u306b\u3082GC\/MS\u306e\u4f7f\u7528\u304c\u6700\u9069\u3067\u306f\u306a\u3044\u5206\u6790\u304c\u3042\u308a\u307e\u3059\u3002\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u5206\u6790\u5bfe\u8c61\u6210\u5206\uff08\u5316\u5408\u7269\uff09\u3068\u691c\u51fa\u5668\u306e\u7d44\u5408\u305b\u3092\u63a8\u5968\u3057\u307e\u3059\u3002\u3059\u3079\u3066\u3092\u7db2\u7f85\u3057\u3066\u3044\u308b\u308f\u3051\u3067\u306f\u306a\u3044\u3053\u3068\u306b\u3054\u7559\u610f\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u8efd\u8cea\u70ad\u5316\u6c34\u7d20\uff08\u30e1\u30bf\u30f3\u3001\u30a8\u30bf\u30f3\u3001\u30d7\u30ed\u30d1\u30f3\u3001\u30d6\u30bf\u30f3\u306a\u3069\u3001\u304a\u3088\u3073\u305d\u306e\u95a2\u9023\u5316\u5408\u7269\/\u7570\u6027\u4f53\uff09\u2013 FID\u304c\u6700\u9069<\/li>\n\n\n\n<li>\u30db\u30eb\u30e0\u30a2\u30eb\u30c7\u30d2\u30c9\uff08\u304a\u3088\u3073\u6c34\u84b8\u6c17\uff09\u2013 TCD\u3001HID\u3001DID\u304c\u6700\u9069<\/li>\n\n\n\n<li>\u30a2\u30f3\u30e2\u30cb\u30a2 \u2013 TCD\u3001HID\u3001DID\u3001IRD\u304c\u6700\u9069<\/li>\n\n\n\n<li>\u786b\u5316\u6c34\u7d20\uff08\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u8efd\u8cea\u786b\u9ec4\u30ac\u30b9\uff09\u2013 SCD\u3001FPD\u304c\u6700\u9069<\/li>\n\n\n\n<li>\u30e1\u30bf\u30ce\u30fc\u30eb\u304a\u3088\u3073\/\u307e\u305f\u306f\u30a2\u30bb\u30c8\u30a2\u30eb\u30c7\u30d2\u30c9\uff08\u304a\u3088\u3073\u305d\u306e\u4ed6\u306e\u8efd\u8cea\u30a2\u30eb\u30b3\u30fc\u30eb\/\u6eb6\u5a92\uff09\u2013 FID\u304c\u6700\u9069<\/li>\n\n\n\n<li>\u30a8\u30c1\u30ec\u30f3\uff08\u304a\u3088\u3073\u30d7\u30ed\u30d4\u30ec\u30f3\uff09\u30b0\u30ea\u30b3\u30fc\u30eb \u2013 FID\u304c\u6700\u9069<\/li>\n\n\n\n<li>\u9ad8\u6cb8\u70b9\u5316\u5408\u7269\uff08\u7d04450\u2103\u3092\u8d85\u3048\u308b\u6cb8\u70b9\uff09\u2013 FID\u304c\u6700\u9069<\/li>\n<\/ol>\n\n\n\n<ul class=\"wp-block-list\">\n<li>TCD = \u71b1\u4f1d\u5c0e\u5ea6\u691c\u51fa\u5668<\/li>\n\n\n\n<li>HID = \u30d8\u30ea\u30a6\u30e0\u30a4\u30aa\u30f3\u5316\u691c\u51fa\u5668<\/li>\n\n\n\n<li>DID = \u653e\u96fb\u30a4\u30aa\u30f3\u5316\u691c\u51fa\u5668<\/li>\n\n\n\n<li>IRD = \u8d64\u5916\u7dda\u691c\u51fa\u5668<\/li>\n\n\n\n<li>SCD = \u786b\u9ec4\u5316\u5b66\u767a\u5149\u691c\u51fa\u5668<\/li>\n\n\n\n<li>FPD = \u708e\u5149\u5149\u5ea6\u691c\u51fa\u5668<\/li>\n\n\n\n<li>FID = \u708e\u30a4\u30aa\u30f3\u5316\u691c\u51fa\u5668<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u8a18\u306e\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3001\u5225\u306e\u691c\u51fa\u5668\uff08TCD\u3001FID\u3001\u307e\u305f\u306f\u786b\u9ec4\u7279\u7570\u7684\u691c\u51fa\u5668\u306a\u3069\uff09\u3092\u63a8\u5968\u3059\u308b\u7406\u7531\u3092\u4ee5\u4e0b\u306e\u901a\u308a\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u30017. \u9ad8\u6cb8\u70b9\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u3001\u691c\u51fa\u5668\u3068\u3057\u3066\u306e\u30d5\u30a1\u30fc\u30b9\u30c8\u30c1\u30e7\u30a4\u30b9\u306fFID\u3068\u8003\u3048\u307e\u3059\u3002\u3068\u3044\u3046\u306e\u3082\u3001\u6cb8\u70b9\u304c450\u2103\u3092\u8d85\u3048\u308b\u5316\u5408\u7269\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\/\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u53e3\u3092\u901a\u904e\u3067\u304d\u305f\u3068\u3057\u3066\u3082\u3001\u8cea\u91cf\u5206\u6790\u8a08\u306e\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30e9\u30a4\u30f3\u5185\u3067\u51dd\u7e2e\u3057\u3066\u3057\u307e\u3046\u30ea\u30b9\u30af\u304c\u9ad8\u3044\u305f\u3081\u3067\u3059\u3002\u300c\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30e9\u30a4\u30f3\u306e\u6e29\u5ea6\u3092\u6700\u5927\u306b\u3059\u308c\u3070\u3044\u3044\u300d\u3068\u8003\u3048\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u304c\u3001\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30c1\u30e5\u30fc\u30d6\u3092\u7d04300\u2103\u3092\u8d85\u3048\u308b\u6e29\u5ea6\u306b\u5e38\u6642\u3055\u3089\u3059\u3068\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u30c1\u30e5\u30fc\u30d6\u306e\u30dd\u30ea\u30a4\u30df\u30c9\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u304c\u6642\u9593\u306e\u7d4c\u904e\u3068\u3068\u3082\u306b\u5265\u304c\u308c\u843d\u3061\u3001\u30ab\u30e9\u30e0\u304c\u8106\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u3053\u306e\u3088\u3046\u306a\u9ad8\u6e29\u306b\u8010\u3048\u308b\u3053\u3068\u304c\u51fa\u6765\u308bMXT\u30ab\u30e9\u30e0\u3082\u88fd\u9020\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u901a\u5e38\u306f\u8cea\u91cf\u5206\u6790\u8a08\u3067\u306e\u4f7f\u7528\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u30bd\u30fc\u30b9\u5185\u90e8\u3067\u30a2\u30fc\u30af\u653e\u96fb\u304c\u767a\u751f\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u304b\u3089\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001\u305d\u308c\u4ee5\u5916\u306e1.\u301c6.\u306e\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u3001\u8cea\u91cf\u5206\u6790\u8a08\u306e\u4f7f\u7528\u3092\u63a8\u5968\u3057\u306a\u3044\u7406\u7531\u306f\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306e\u30de\u30b9\u30b9\u30da\u30af\u30c8\u30eb\u3092\u898b\u308c\u3070\u5206\u304b\u308a\u307e\u3059\u3002\u5404\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u3001\u4e3b\u8981\u306am\/z\u306f45\u672a\u6e80\u3092\u793a\u3057\u307e\u3059\u304c\u3001\u3053\u308c\u306f\u8cea\u91cf\u5206\u6790\u30a2\u30ca\u30ea\u30b9\u30c8\u306a\u3089\u8ab0\u3067\u3082\u77e5\u3063\u3066\u3044\u308b\u3088\u3046\u306b\u3001\u6c7a\u3057\u3066\u7406\u60f3\u7684\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3053\u306e\u4f4e\u3044\u7bc4\u56f2\u3092\u30b9\u30ad\u30e3\u30f3\u3057\u305f\u3068\u304d\u306b\u3001\u5e72\u6e09\u304c\u591a\u3059\u304e\u308b\u305f\u3081\u3067\u3059\uff08\u975e\u5e38\u306b\u9ad8\u3044\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3068\u611f\u5ea6\u4f4e\u4e0b\u304c\u4e00\u822c\u7684\u306b\u5831\u544a\u3055\u308c\u3066\u3044\u307e\u3059\uff09\u3002\u8cea\u91cf\u5206\u6790\u8a08\u304c\u4f7f\u7528\u53ef\u80fd\u304b\u3001\u307e\u305f\u306f\u4f7f\u7528\u3059\u3079\u304d\u304b\u3092\u5224\u65ad\u3059\u308b\u524d\u306b\u3001\u5e38\u306b<a href=\"http:\/\/webbook.nist.gov\/chemistry\/\" target=\"_blank\" rel=\"noreferrer noopener\">NIST Chemistry WebBook<\/a>\u3067\u30de\u30b9\u30b9\u30da\u30af\u30c8\u30eb\u3092\u691c\u7d22\u3059\u308b\u306e\u304c\u826f\u3044\u3067\u3057\u3087\u3046\u3002\u76ee\u7684\u306e\u5316\u5408\u7269\u5185\u306e\u3059\u3079\u3066\u306e\u30a4\u30aa\u30f3\u304cm\/z &nbsp;45\u672a\u6e80\u306e\u5834\u5408\u3001\u8cea\u91cf\u5206\u6790\u8a08\u3067\u306f\u306a\u3044\u691c\u51fa\u5668\u3092\u9069\u7528\u3059\u308b\u3088\u3046\u306b\u3057\u307e\u3057\u3087\u3046\u3002NIST Web\u30b5\u30a4\u30c8\u304b\u3089\u306e\u30de\u30b9\u30b9\u30da\u30af\u30c8\u30eb\u306e\u4f8b\u3092\u4ee5\u4e0b\u306e\u901a\u308a\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306e\u30d7\u30ed\u30b8\u30a7\u30af\u30c8\u306bGC\/MS\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u6c7a\u5b9a\u3059\u308b\u524d\u306b\u3001\u8cea\u91cf\u5206\u6790\u8a08\u304c\u672c\u5f53\u306b\u6700\u9069\u306a\u691c\u51fa\u5668\u3068\u3057\u3066\u306e\u9078\u629e\u3067\u3042\u308b\u304b\u3069\u3046\u304b\u3092\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u304a\u8aad\u307f\u3044\u305f\u3060\u304d\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-when-not-to-use-gc-mass-spec-01.gif\" alt=\"decorative\" class=\"wp-image-6673\" title=\"-\"><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-when-not-to-use-gc-mass-spec-02.gif\" alt=\"decorative\" class=\"wp-image-6674\" title=\"-\"><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-when-not-to-use-gc-mass-spec-03.gif\" alt=\"decorative\" class=\"wp-image-6675\" title=\"-\"><\/figure>\n<\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>GC\u5206\u6790\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u30c7\u30fc\u30bf\u3092\u5f97\u308b\u306b\u306f\u3001\u5316\u5408\u7269\u7279\u6027\u306b\u5fdc\u3058\u305f\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3068\u691c\u51fa\u5668\u306e\u9078\u5b9a\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u6c38\u4e45\u30ac\u30b9\u304b\u3089\u9ad8\u6cb8\u70b9\u5316\u5408\u7269\u307e\u3067\u3001\u5206\u6790\u5bfe\u8c61\u306b\u5408\u308f\u305b\u305f\u6700\u9069\u306a\u9078\u3073\u65b9\u3092\u89e3\u8aac\u3002GC\/MS\u3001TCD\u3001FID\u306a\u3069\u3001\u691c\u51fa\u5668\u306e\u7279\u6027\u3068\u30ab\u30e9\u30e0\u9078\u5b9a\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u5c02\u9580\u5bb6\u304c\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[582],"class_list":["post-48539","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/ja\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48539","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48539"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48539\/revisions"}],"predecessor-version":[{"id":83681,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48539\/revisions\/83681"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48539"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48539"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48539"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48539"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48539"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48539"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48539"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48539"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48539"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}