{"id":48541,"date":"2019-08-07T14:30:00","date_gmt":"2019-08-07T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/gc-inlet-liner-selection-part-i-splitless-liner-selection-japan\/"},"modified":"2026-01-21T18:40:17","modified_gmt":"2026-01-21T18:40:17","slug":"gc-inlet-liner-selection-part-i-splitless-liner-selection-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4679-ja\/gc-inlet-liner-selection-part-i-splitless-liner-selection-japan","title":{"rendered":"GC\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u3073\u65b9 \u7b2cI\u90e8\uff1a\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u5fb9\u5e95\u89e3\u8aac"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\" id=\"top\">\u76ee\u6b21<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><a href=\"#sec01\">\u306f\u3058\u3081\u306b<\/a>\n<ul class=\"wp-block-list\">\n<li>\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3051\u308b\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u91cd\u8981\u6027<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#sec02\">\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306e\u91cd\u8981\u6027\u3068\u8ab2\u984c<\/a>\n<ul class=\"wp-block-list\">\n<li>\u6d41\u901f\u306e\u5f71\u97ff\u3068\u6d3b\u6027\u90e8\u4f4d\u3068\u306e\u76f8\u4e92\u4f5c\u7528<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#sec03\">\u5b9f\u9a13\u306e\u6982\u8981\u3068\u88c5\u7f6e\u6761\u4ef6<\/a>\n<ul class=\"wp-block-list\">\n<li>\u5b9f\u9a13\u306e\u76ee\u7684\u3068\u8a2d\u5b9a\u6761\u4ef6<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#sec04\">\u30e9\u30a4\u30ca\u30fc\u306e\u7a2e\u985e\u3068\u7279\u5fb4<\/a>\n<ul class=\"wp-block-list\">\n<li>\u30a6\u30fc\u30eb\u5165\u308a\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc<\/li>\n\n\n\n<li>\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc<\/li>\n\n\n\n<li>\u30a6\u30fc\u30eb\u306a\u3057\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc<\/li>\n\n\n\n<li>\u4f4e\u5727\u640d\u30e9\u30a4\u30ca\u30fc\uff08LPD\uff09<\/li>\n\n\n\n<li>\u30b5\u30a4\u30af\u30ed\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#sec05\">\u30d4\u30fc\u30af\u9762\u7a4d\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u6bd4\u8f03<\/a>\n<ul class=\"wp-block-list\">\n<li>Figure 1: \u5404\u30e9\u30a4\u30ca\u30fc\u306e\u6bd4\u8f03\u7d50\u679c<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#sec06\">\u518d\u73fe\u6027\u306e\u6bd4\u8f03\u3068\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e<\/a>\n<ul class=\"wp-block-list\">\n<li>Figure 2: \u518d\u73fe\u6027\u8a55\u4fa1\u7d50\u679c<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u306e\u6c5a\u67d3\u9632\u6b62\u306b\u5f79\u7acb\u3064\u30dd\u30a4\u30f3\u30c8<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li><a href=\"#sec07\">\u7d50\u8ad6\u3068\u63a8\u5968\u4e8b\u9805<\/a>\n<ul class=\"wp-block-list\">\n<li>\u63a8\u5968\u3059\u308b\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u80a2<\/li>\n\n\n\n<li>\u30e9\u30a4\u30ca\u30fc\u306e\u6700\u9069\u5316\u306e\u91cd\u8981\u6027<\/li>\n<\/ul>\n<\/li>\n<\/ol>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec01\">1. \u306f\u3058\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306f\u30b5\u30f3\u30d7\u30eb\u5c0e\u5165\u306e\u52b9\u7387\u306b\u76f4\u63a5\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u91cd\u8981\u306a\u90e8\u54c1\u3067\u3059\u3002\u7279\u306b\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u4f7f\u7528\u3057\u3066\u5fae\u91cf\u6210\u5206\u306e\u5206\u6790\u3092\u884c\u3046\u5834\u5408\u3001\u9069\u5207\u306a\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u304c\u5206\u6790\u7d50\u679c\u306b\u5927\u304d\u306a\u9055\u3044\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002\u30e9\u30a4\u30ca\u30fc\u306e\u5f62\u72b6\u3084\u6750\u8cea\u304c\u5206\u6790\u6210\u5206\u306e\u6c17\u5316\u3084\u30ab\u30e9\u30e0\u3078\u306e\u5c0e\u5165\u52b9\u7387\u3092\u5de6\u53f3\u3059\u308b\u305f\u3081\u3001\u9078\u629e\u3092\u8aa4\u308b\u3068\u30d4\u30fc\u30af\u306e\u5e83\u304c\u308a\u3084\u30b5\u30f3\u30d7\u30eb\u306e\u30e9\u30a4\u30ca\u30fc\u5185\u3067\u306e\u6ede\u7559\u306b\u3088\u308b\u6d3b\u6027\u90e8\u4f4d\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u306e\u5897\u52a0\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u8a18\u4e8b\u3067\u306f\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u304a\u3051\u308b\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u5b9a\u3059\u308b\u305f\u3081\u3001\u3055\u307e\u3056\u307e\u306a\u5f62\u72b6\u306e\u30e9\u30a4\u30ca\u30fc\u3092\u6bd4\u8f03\u3057\u305f\u5b9f\u9a13\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u307e\u3059\u3002\u4eca\u56de\u306e\u5b9f\u9a13\u3067\u306f\u3001C10\u304b\u3089C40\u307e\u3067\u306e\u5e83\u7bc4\u306a\u5206\u5b50\u91cf\u3092\u6301\u3064\u70ad\u5316\u6c34\u7d20\u7cfb\u5316\u5408\u7269\u3092\u4f7f\u7528\u3057\u3001\u30d4\u30fc\u30af\u9762\u7a4d\u30ec\u30b9\u30dd\u30f3\u30b9\u3068\u518d\u73fe\u6027\u3092\u8a55\u4fa1\u3059\u308b\u3053\u3068\u3067\u3001\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u306e\u7279\u5fb4\u3092\u660e\u3089\u304b\u306b\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec02\">2. \u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306e\u91cd\u8981\u6027\u3068\u8ab2\u984c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u307b\u307c\u3059\u3079\u3066\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u5834\u5408\u306b\u7528\u3044\u3089\u308c\u307e\u3059\u3002\u6ce8\u5165\u76f4\u5f8c\u306b\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u3092\u9589\u3058\u3001\u3059\u3079\u3066\u306e\u30d5\u30ed\u30fc\u3092\u30ab\u30e9\u30e0\u306b\u9001\u308a\u8fbc\u3080\u3053\u3068\u3067\u9ad8\u3044\u56de\u53ce\u7387\u304c\u5f97\u3089\u308c\u307e\u3059\u304c\u3001\u6d41\u901f\u304c\u9045\u304f\u306a\u308b\u305f\u3081\u3001\u30e9\u30a4\u30ca\u30fc\u5185\u3067\u306e\u30b5\u30f3\u30d7\u30eb\u6ede\u7559\u6642\u9593\u304c\u9577\u304f\u306a\u308a\u3001\u6d3b\u6027\u90e8\u4f4d\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u5897\u52a0\u3059\u308b\u3053\u3068\u3067\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u3084\u611f\u5ea6\u306e\u4f4e\u4e0b\u306b\u3064\u306a\u304c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec03\">3. \u5b9f\u9a13\u306e\u6982\u8981\u3068\u88c5\u7f6e\u6761\u4ef6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u5b9f\u9a13\u3067\u306f\u3001<strong>Table 1<\/strong>\u306b\u8a18\u8f09\u306e\u30e9\u30a4\u30ca\u30fc\u3068\u5206\u6790\u6761\u4ef6\u3092\u7528\u3044\u3066\u3001\u5f62\u72b6\u306e\u7570\u306a\u308b\u30e9\u30a4\u30ca\u30fc\u3092\u6bd4\u8f03\u3057\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u304a\u3044\u3066\u3069\u306e\u30e9\u30a4\u30ca\u30fc\u304c\u9ad8\u3044\u518d\u73fe\u6027\u3068\u5747\u4e00\u306a\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u793a\u3059\u306e\u304b\u5b9f\u9a13\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-gc-inlet-liner-selection-part-i-splitless-liner-selection-01.png\" alt=\"decorative\" class=\"wp-image-61428\" title=\"-\"><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"468\" height=\"346\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-gc-inlet-liner-selection-part-i-splitless-liner-selection-02.png\" alt=\"\" class=\"wp-image-14721\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-gc-inlet-liner-selection-part-i-splitless-liner-selection-02.png 468w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-gc-inlet-liner-selection-part-i-splitless-liner-selection-02-300x222.png 300w\" sizes=\"auto, (max-width: 468px) 100vw, 468px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table 1<\/strong>: \u672c\u5b9f\u9a13\u306b\u7528\u3044\u305f\u30e9\u30a4\u30ca\u30fc\u5404\u7a2e\u3068\u88c5\u7f6e\u6761\u4ef6<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec04\">4. \u30e9\u30a4\u30ca\u30fc\u306e\u7a2e\u985e\u3068\u7279\u5fb4<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong><em>Figure 1<\/em><\/strong>\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u7570\u306a\u308b\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u3092\u4f7f\u7528\u3057\u3066\u3001\u30d4\u30fc\u30af\u9762\u7a4d\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u305d\u308c\u305e\u308c\u306e\u30e9\u30a4\u30ca\u30fc\u304c\u6301\u3064\u7279\u6027\u3092\u4ee5\u4e0b\u306b\u89e3\u8aac\u3057\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23303\" target=\"_blank\" rel=\"noreferrer noopener\">Topaz 4mm \u30a6\u30fc\u30eb\u5165\u308a\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08Single Taper Liner w\/ Wool\uff09<\/a><br><\/strong>\u30a6\u30fc\u30eb\u304c\u5165\u3063\u3066\u304a\u308a\u3001\u6c17\u5316\u306e\u4fc3\u9032\u3068\u30b5\u30f3\u30d7\u30eb\u30ad\u30e3\u30c3\u30c1\u52b9\u679c\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u30c6\u30fc\u30d1\u30fc\u5f62\u72b6\u306b\u3088\u308a\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u30ab\u30e9\u30e0\u3078\u30b9\u30e0\u30fc\u30ba\u306b\u5c0e\u5165\u3055\u308c\u3001\u30d4\u30fc\u30af\u306e\u30b7\u30e3\u30fc\u30d7\u30cd\u30b9\u304c\u5411\u4e0a\u3057\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3067\u306f\u7279\u306b\u9ad8\u3044\u56de\u53ce\u7387\u304c\u671f\u5f85\u3067\u304d\u3001\u518d\u73fe\u6027\u306e\u826f\u3055\u304c\u7279\u5fb4\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23302\" target=\"_blank\" rel=\"noreferrer noopener\">Topaz 4mm \u30a6\u30fc\u30eb\u306a\u3057\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08Single Taper Liner\uff09<\/a><br><\/strong>\u30c6\u30fc\u30d1\u30fc\u5f62\u72b6\u306b\u3088\u308a\u30b5\u30f3\u30d7\u30eb\u306e\u5c0e\u5165\u304c\u30b9\u30e0\u30fc\u30ba\u3067\u3001\u30d4\u30fc\u30af\u306e\u5e45\u304c\u6291\u3048\u3089\u308c\u307e\u3059\u3002\u30a6\u30fc\u30eb\u304c\u306a\u3044\u305f\u3081\u3001\u6c17\u5316\u52b9\u7387\u306b\u3084\u3084\u5236\u9650\u304c\u3042\u308b\u3082\u306e\u306e\u3001\u63ee\u767a\u6027\u304c\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u306b\u306f\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23301\" target=\"_blank\" rel=\"noreferrer noopener\">Topaz 4mm \u30a6\u30fc\u30eb\u306a\u3057\u30b9\u30c8\u30ec\u30fc\u30c8\u30e9\u30a4\u30ca\u30fc\uff08Straight Liner\uff09<\/a><br><\/strong>\u30a6\u30fc\u30eb\u3084\u4ed6\u306e\u969c\u5bb3\u7269\u304c\u306a\u3044\u30b7\u30f3\u30d7\u30eb\u306a\u8a2d\u8a08\u3067\u3001\u6c17\u5316\u52b9\u7387\u304c\u4f4e\u304f\u3001\u7279\u306b\u63ee\u767a\u6027\u306e\u9ad8\u3044\u30b5\u30f3\u30d7\u30eb\u306b\u5bfe\u3059\u308b\u30ec\u30b9\u30dd\u30f3\u30b9\u304c\u4e0d\u5b89\u5b9a\u306b\u306a\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3067\u306e\u4f7f\u7528\u306f\u9650\u5b9a\u7684\u3067\u3059\u304c\u3001\u7279\u5b9a\u306e\u7528\u9014\u306b\u304a\u3044\u3066\u9069\u5207\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23467\" target=\"_blank\" rel=\"noreferrer noopener\">Topaz 4mm \u4f4e\u5727\u640d\u30e9\u30a4\u30ca\u30fc\uff08Low Pressure Drop Liner\uff09<\/a><br><\/strong>\u5727\u529b\u30c9\u30ed\u30c3\u30d7\u3092\u6291\u3048\u308b\u8a2d\u8a08\u306b\u3088\u308a\u3001\u30ac\u30b9\u30d5\u30ed\u30fc\u304c\u5b89\u5b9a\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u3063\u3066\u3001\u5206\u6790\u4e2d\u306e\u30b5\u30f3\u30d7\u30eb\u306e\u6c17\u5316\u3068\u79fb\u9001\u304c\u3088\u308a\u4e00\u5b9a\u3068\u306a\u308a\u3001\u9ad8\u5206\u5b50\u91cf\u5316\u5408\u7269\u3084\u63ee\u767a\u6027\u306e\u4f4e\u3044\u6210\u5206\u306e\u5b89\u5b9a\u7684\u306a\u79fb\u9001\u3092\u30b5\u30dd\u30fc\u30c8\u3057\u307e\u3059\u3002\u7279\u306b\u3001\u5727\u529b\u5909\u52d5\u306b\u3088\u308b\u5f71\u97ff\u304c\u5c11\u306a\u304f\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u826f\u597d\u306b\u4fdd\u3061\u3084\u3059\u3044\u3053\u3068\u304c\u7279\u5fb4\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23310\" target=\"_blank\" rel=\"noreferrer noopener\">Topaz 4mm \u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30b5\u30a4\u30af\u30ed\u30e9\u30a4\u30ca\u30fc\uff08Double Taper Cyclo Liner\uff09<\/a><br><\/strong>\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u69cb\u9020\u3068\u30b5\u30a4\u30af\u30ed\u5f62\u72b6\u306b\u3088\u3063\u3066\u5e83\u3044\u8868\u9762\u7a4d\u3092\u6301\u3061\u3001\u6c17\u5316\u52b9\u7387\u3092\u9ad8\u3081\u307e\u3059\u3002\u30a6\u30fc\u30eb\u306a\u3057\u306e\u8a2d\u8a08\u3067\u3059\u304c\u3001\u52b9\u7387\u7684\u306a\u6c17\u5316\u3092\u5b9f\u73fe\u3057\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u304a\u3051\u308b\u518d\u73fe\u6027\u3082\u826f\u597d\u3067\u3059\u3002\u63ee\u767a\u6027\u306e\u4f4e\u3044\u5316\u5408\u7269\u3084\u5e45\u5e83\u3044\u5206\u5b50\u91cf\u7bc4\u56f2\u3067\u9ad8\u3044\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u767a\u63ee\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec05\">5. \u30d4\u30fc\u30af\u9762\u7a4d\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u6bd4\u8f03<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 1<\/strong>\u306f\u5f62\u72b6\u306e\u7570\u306a\u308b\u4e00\u822c\u7684\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u7528\u3044\u3066\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3092\u884c\u3044\u3001\u5e83\u7bc4\u56f2\u306a\u5206\u5b50\u91cf\u6210\u5206\u306b\u308f\u305f\u3063\u3066\u30d4\u30fc\u30af\u9762\u7a4d\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u6bd4\u8f03\u3057\u305f\u7d50\u679c\u3067\u3059\u3002\u5b9f\u9a13\u306b\u306fC10 \u304b\u3089C40\u306e\u70ad\u5316\u6c34\u7d20\u3092\u7528\u3044\u3066\u304a\u308a\u3001\u6a2a\u8ef8\u306f\u70ad\u7d20\u539f\u5b50\u306e\u6570\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-gc-inlet-liner-selection-part-i-splitless-liner-selection-03.png\" alt=\"decorative\" width=\"905\" height=\"565\" title=\"-\"><br><strong>Figure 1<\/strong>: \u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u30e2\u30fc\u30c9\u3067\u4f7f\u7528\u3055\u308c\u308b\u3055\u307e\u3056\u307e\u306a\u30e9\u30a4\u30ca\u30fc\u5f62\u72b6\u306b\u304a\u3051\u308b\u5e83\u7bc4\u56f2\u306a\u5206\u5b50\u91cf\u6210\u5206\u3067\u306e\u30d4\u30fc\u30af\u9762\u7a4d\u30ec\u30b9\u30dd\u30f3\u30b9\u306e\u6bd4\u8f03<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30c7\u30a3\u30b9\u30af\u30ea\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u306b\u5747\u7b49\u306a\u30ec\u30b9\u30dd\u30f3\u30b9\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u9069\u5207\u306aGC\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u304c\u91cd\u8981\u3067\u3059\u3002\u5b9f\u9a13\u7d50\u679c\u304b\u3089\u306f\u3001<strong>\u30a6\u30fc\u30eb\u5165\u308a\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08Single Taper w\/Wool\uff09<\/strong> \u3068 <strong>\u30b5\u30a4\u30af\u30ed\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08Double Taper Cyclo\uff09<\/strong> \u304c\u3053\u306e\u7406\u60f3\u3092\u5b9f\u73fe\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3057\u305f\uff08<strong>Figure 1<\/strong>\u53c2\u7167\uff09\u3002\u3053\u308c\u3089\u306e\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30a6\u30fc\u30eb\u3084\u30b5\u30a4\u30af\u30ed\u69cb\u9020\u306b\u3088\u308a\u5185\u90e8\u306e\u8868\u9762\u7a4d\u304c\u5e83\u304c\u308a\u3001\u71b1\u5bb9\u91cf\u304c\u5897\u52a0\u3059\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6c17\u5316\u3092\u4fc3\u9032\u3057\u3001\u9ad8\u611f\u5ea6\u306aGC\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e00\u65b9\u3001<strong>\u4f4e\u5727\u640d\u30e9\u30a4\u30ca\u30fc\uff08LPD\uff09<\/strong> \u3082C20\u4ee5\u4e0a\u306e\u9ad8\u5206\u5b50\u91cf\u70ad\u5316\u6c34\u7d20\u306b\u5bfe\u3057\u3066\u306f\u512a\u308c\u305f\u6027\u80fd\u3092\u793a\u3057\u307e\u3057\u305f\u304c\u3001\u63ee\u767a\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u306f\u4e00\u90e8\u306e\u30b5\u30f3\u30d7\u30eb\u640d\u5931\u304c\u898b\u3089\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001LPD\u30e9\u30a4\u30ca\u30fc\u3067\u306f\u30a6\u30fc\u30eb\u304c\u9ad8\u3044\u4f4d\u7f6e\u306b\u914d\u7f6e\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\u30d9\u30f3\u30c8\u306e\u5f71\u97ff\u3092\u53d7\u3051\u3084\u3059\u304f\u306a\u308b\u3053\u3068\u304c\u539f\u56e0\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u30c6\u30fc\u30d1\u30fc\u5f62\u72b6\u3082\u5927\u304d\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u307e\u3059\u3002\u30c6\u30fc\u30d1\u30fc\u304c\u3042\u308b\u3053\u3068\u3067\u3001\u30ab\u30e9\u30e0\u3078\u306e\u30b5\u30f3\u30d7\u30eb\u5c0e\u5165\u304c\u30b9\u30e0\u30fc\u30ba\u306b\u306a\u308a\u3001\u30b4\u30fc\u30eb\u30c9\u30b7\u30fc\u30eb\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u307e\u3059\u3002\u30c6\u30fc\u30d1\u30fc\u304c\u306a\u3044\u5834\u5408\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u6642\u306b\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u6d41\u901f\u304c\u9045\u304f\u306a\u308a\u3001\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u306b\u60aa\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec06\">6. \u518d\u73fe\u6027\u306e\u6bd4\u8f03\u3068\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u518d\u73fe\u6027\u306e\u8a55\u4fa1\u3067\u306f\u3001\u30a6\u30fc\u30eb\u5165\u308a\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u3068\u30b5\u30a4\u30af\u30ed\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u304c\u6700\u3082\u5b89\u5b9a\u6027\u3092\u793a\u3057\u307e\u3057\u305f\uff08<strong>Figure 2<\/strong>\u53c2\u7167\uff09\u3002\u3053\u308c\u3089\u306e\u30e9\u30a4\u30ca\u30fc\u306f\u3001\u30a6\u30fc\u30eb\u3084\u30b5\u30a4\u30af\u30ed\u69cb\u9020\u306b\u3088\u308b\u652a\u62cc\u52b9\u679c\u304c\u9ad8\u304f\u3001\u6ce8\u5165\u6642\u306b\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u30b5\u30f3\u30d7\u30eb\u306e\u5747\u4e00\u306a\u6df7\u5408\u3092\u4fc3\u9032\u3059\u308b\u305f\u3081\u3001\u5e45\u5e83\u3044\u5206\u5b50\u91cf\u306e\u6210\u5206\u306b\u304a\u3044\u3066\u5b89\u5b9a\u3057\u305f\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u3082\u3088\u308a\u307e\u3059\u304c\u3001\u30a6\u30fc\u30eb\u3084\u30b5\u30a4\u30af\u30ed\u69cb\u9020\u306b\u306f\u3001\u4e0d\u63ee\u767a\u6027\u7269\u8cea\u3084\u30bb\u30d7\u30bf\u30e0\u7c92\u5b50\u3092\u300c\u30ad\u30e3\u30c3\u30c1\u300d\u3059\u308b\u6a5f\u80fd\u3082\u671f\u5f85\u3067\u304d\u308b\u305f\u3081\u3001\u30ab\u30e9\u30e0\u306e\u4e88\u671f\u305b\u306c\u6c5a\u67d3\u3092\u9632\u6b62\u3057\u3001\u5206\u6790\u611f\u5ea6\u4f4e\u4e0b\u3092\u6291\u3048\u3066\u5b89\u5b9a\u3057\u305f\u4fe1\u983c\u6027\u306e\u9ad8\u3044GC\u5206\u6790\u5b9f\u73fe\u306b\u5f79\u7acb\u3064\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 2: \u5e83\u7bc4\u56f2\u306a\u5206\u5b50\u91cf\u6210\u5206\u306b\u304a\u3051\u308b\u30e9\u30a4\u30ca\u30fc\u306e\u518d\u73fe\u6027\u6bd4\u8f03<\/strong><br>\u3053\u306e\u7d50\u679c\u304b\u3089\u3001\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u629e\u304c\u5206\u6790\u7cbe\u5ea6\u3068\u518d\u73fe\u6027\u306b\u5927\u304d\u304f\u5bc4\u4e0e\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-gc-inlet-liner-selection-part-i-splitless-liner-selection-04.png\" alt=\"decorative\" width=\"923\" height=\"589\" title=\"-\"><br><strong>Figure 2<\/strong>: \u5e83\u7bc4\u56f2\u306a\u5206\u5b50\u91cf\u6210\u5206\u306b\u304a\u3051\u308b\u30e9\u30a4\u30ca\u30fc\u306e\u518d\u73fe\u6027\u6bd4\u8f03<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"sec07\">7. \u7d50\u8ad6\u3068\u63a8\u5968\u4e8b\u9805<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9f\u9a13\u7d50\u679c\u304b\u3089\u3001Restek\u306f\u4ee5\u4e0b\u306e\u30e9\u30a4\u30ca\u30fc\u3092\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u63a8\u5968\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>\u30a6\u30fc\u30eb\u5165\u308a\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08Single Taper w\/Wool\uff09(<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23303\" target=\"_blank\" rel=\"noreferrer noopener\">cat#23303<\/a>)<\/strong><br>\u8cbb\u7528\u5bfe\u52b9\u679c\u306b\u512a\u308c\u305f\u9078\u629e\u80a2\u3067\u3001\u5e45\u5e83\u3044\u7528\u9014\u306b\u5bfe\u5fdc\u3059\u308b\u305f\u3081\u306b\u6700\u9069\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong>\u30b5\u30a4\u30af\u30ed\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\uff08Double Taper Cyclo\uff09(<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23310\" target=\"_blank\" rel=\"noreferrer noopener\">cat#23310<\/a>)<\/strong><br>\u30a6\u30fc\u30eb\u3092\u4f7f\u7528\u305b\u305a\u306b\u9ad8\u3044\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306e\u9078\u629e\u80a2\u3067\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"wp-block-paragraph\">\u7279\u5b9a\u306e\u6761\u4ef6\u3084\u30b5\u30f3\u30d7\u30eb\u7279\u6027\u306b\u5fdc\u3058\u305f\u30e9\u30a4\u30ca\u30fc\u306e\u6700\u9069\u5316\u306f\u3001\u5206\u6790\u7d50\u679c\u3092\u5927\u304d\u304f\u6539\u5584\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u4e0d\u63ee\u767a\u6027\u7269\u8cea\u3084\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u6c5a\u67d3\u9632\u6b62\u3082\u542b\u3081\u3066\u3001\u9069\u5207\u306a\u30e9\u30a4\u30ca\u30fc\u3092\u9078\u3076\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"#top\">\u2192 \u76ee\u6b21\u306b\u623b\u308b<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">                                \u30ab\u30bf\u30ed\u30b0No. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23310\">                                \u30ab\u30bf\u30ed\u30b0No. 23310                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Cyclo Double Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23310\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23302\">                                \u30ab\u30bf\u30ed\u30b0No. 23302                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23302\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23301\">                                \u30ab\u30bf\u30ed\u30b0No. 23301                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Straight Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23301\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23467\">                                \u30ab\u30bf\u30ed\u30b0No. 23467                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Low Pressure Drop Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, w\/ Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23467\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>GC\u306e\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u306b\u304a\u3051\u308b\u6700\u9069\u306a\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306e\u9078\u3073\u65b9\u3092\u5fb9\u5e95\u89e3\u8aac\u3002\u30a6\u30fc\u30eb\u5165\u308a\u30b7\u30f3\u30b0\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u3084\u30b5\u30a4\u30af\u30ed\u30c0\u30d6\u30eb\u30c6\u30fc\u30d1\u30fc\u30e9\u30a4\u30ca\u30fc\u306e\u7279\u5fb4\u3001\u30d4\u30fc\u30af\u9762\u7a4d\u30ec\u30b9\u30dd\u30f3\u30b9\u3068\u518d\u73fe\u6027\u3092\u6bd4\u8f03\u3057\u3001\u52b9\u7387\u7684\u306aGC\u5206\u6790\u3092\u5b9f\u73fe\u3059\u308b\u305f\u3081\u306e\u6700\u9069\u306a\u30e9\u30a4\u30ca\u30fc\u9078\u5b9a\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u7d39\u4ecb\u3002\u52b9\u7387\u7684\u306a\u5206\u6790\u3068\u30ab\u30e9\u30e0\u306e\u6c5a\u67d3\u9632\u6b62\u306b\u5f79\u7acb\u3064\u60c5\u5831\u3082\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2800],"industries-application":[],"post-badge":[],"resource-type":[2802],"product-library":[],"resource-technique":[2340,2342],"ppma_author":[598],"class_list":["post-48541","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-topaz-liners","resource-type-selection-guides","resource-technique-gas-chromatography-gc-ja","resource-technique-injection-techniques-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2800,"label":"Topaz Liners"}],"resource-type":[{"value":2802,"label":"Selection Guides"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2342,"label":"\u6ce8\u5165\u65b9\u6cd5"}]},"featured_image_src_large":false,"author_info":{"display_name":"Linx Waclaski","author_link":"https:\/\/discover.restek.com\/ja\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2800,"name":"Topaz Liners","slug":"topaz-liners","term_group":0,"term_taxonomy_id":2800,"taxonomy":"post_tag","description":"","parent":0,"count":28,"filter":"raw"}],"authors":[{"term_id":598,"user_id":0,"is_guest":1,"slug":"linx-waclaski","display_name":"Linx Waclaski","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Linx","last_name":"Waclaski","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48541","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48541"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48541\/revisions"}],"predecessor-version":[{"id":83686,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48541\/revisions\/83686"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48541"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48541"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48541"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48541"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48541"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48541"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48541"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48541"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48541"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}