{"id":48544,"date":"2019-06-20T14:30:00","date_gmt":"2019-06-20T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/are-you-interested-in-ultrashort-chain-pfas-analysis-be-sure-to-screen-your-solvents-solutions-for-contamination-japan\/"},"modified":"2026-07-31T21:04:32","modified_gmt":"2026-07-31T21:04:32","slug":"are-you-interested-in-ultrashort-chain-pfas-analysis-be-sure-to-screen-your-solvents-solutions-for-contamination-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4584-ja\/are-you-interested-in-ultrashort-chain-pfas-analysis-be-sure-to-screen-your-solvents-solutions-for-contamination-japan","title":{"rendered":"LC-MS\/MS\u5206\u6790\u306b\u304a\u3051\u308bTFA\u30b3\u30f3\u30bf\u30df\u5bfe\u7b56\uff5c\u8d85\u77ed\u9396PFAS\u6e2c\u5b9a\u306e\u6700\u9069\u306a\u8a66\u85ac\u30fb\u6eb6\u5a92\u30fb\u6d88\u8017\u54c1\u9078\u5b9a"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u30c8\u30ea\u30d5\u30eb\u30aa\u30ed\u9162\u9178\uff08TFA\uff09\u306f\u3001\u30da\u30eb\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff08PFAS\uff09\u306e\u4e2d\u3067\u3001\u6700\u3082\u77ed\u3044\u9396\u9577C2\u3092\u6301\u3064\u9162\u9178\u306e\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u985e\u4f3c\u4f53\u3067\u3001\u30da\u30eb\u30d5\u30eb\u30aa\u30edC3\u5316\u5408\u7269\u3068\u3068\u3082\u306b\u8d85\u77ed\u9396PFAS\u3068\u5b9a\u7fa9\u3055\u308c\u307e\u3059\u3002C2\u304a\u3088\u3073C3 PFAS\u306f\u3001\u96e8\u3001\u96ea\u3001\u6cb3\u5ddd\u3001\u3055\u3089\u306b\u306f\u6d77\u6d0b\u306a\u3069\u306e\u5730\u7403\u4e0a\u306e\u6c34\u751f\u74b0\u5883\u306e\u81f3\u308b\u6240\u306b\u5b58\u5728\u3057\u3001\u9ad8\u3044\u79fb\u52d5\u6027\u3092\u6301\u3061\u307e\u3059\u3002\u7279\u306bTFA\u306f\u3001\u98f2\u6599\u6c34\u3068\u975e\u98f2\u6599\u6c34\u306e\u4e21\u65b9\u306e\u6c34\u6e90\u306b\u975e\u5e38\u306b\u9ad8\u3044\u6fc3\u5ea6\u3067\u5b58\u5728\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u79c1\u305f\u3061\u306f\u8d85\u77ed\u9396PFAS\u5206\u6790\u7528\u306e\u5e0c\u91c8\u30fb\u76f4\u63a5\u6ce8\u5165LC-MS\/MS\u6cd5\u3092\u958b\u767a\u3057\u3066\u3044\u308b\u969b\u306b\u3001HPLC\u30b0\u30ec\u30fc\u30c9\u306e\u6c34\u3068\u30e1\u30bf\u30ce\u30fc\u30eb\u306bTFA\u304c\u6df7\u5165\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u306b\u6c17\u3065\u304d\u307e\u3057\u305f\u3002 \u8d85\u77ed\u9396PFAS\u5206\u6790\u7528\u306eHILIC\/\u30a4\u30aa\u30f3\u4ea4\u63db\u30ab\u30e9\u30e0\u3092\u9069\u7528\u3057\u305f\u3068\u3053\u308d\u3001\u30d6\u30e9\u30f3\u30af\u5e0c\u91c8\u6db2\uff08LC\/MS\u30b0\u30ec\u30fc\u30c9\u306e\u6c34\uff1aHPLC\u30e1\u30bf\u30ce\u30fc\u30eb 50\uff1a50\uff09\u6ce8\u5165\u6642\u306b\u691c\u51fa\u53ef\u80fd\u306aTFA\u30d4\u30fc\u30af\u304c\u89b3\u5bdf\u3055\u308c\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u5206\u6790\u3092\u9032\u3081\u305f\u7d50\u679c\u3001LC\/MS\u30b0\u30ec\u30fc\u30c9\u306e\u6c34\u306b\u306f\u3001LC-MS\/MS\u5206\u6790\u306b\u901a\u5e38\u4f7f\u7528\u3057\u3066\u3044\u308bHPLC\u30b0\u30ec\u30fc\u30c9\u306e\u30e1\u30bf\u30ce\u30fc\u30eb\u3068\u6bd4\u8f03\u3057\u3066\u3001\u6bd4\u8f03\u7684\u9ad8\u3044\u5fae\u91cf\u30ec\u30d9\u30eb\u306eTFA\uff08\uff5e5ppt\uff09\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u308f\u304b\u308a\u307e\u3057\u305f\u3002TFA\u3092\u542b\u307e\u306a\u3044\u8a66\u85ac\u6eb6\u5a92\u3092\u63a2\u3059\u305f\u3081\u3001\u3055\u307e\u3056\u307e\u306a\u696d\u8005\u306e\u3055\u307e\u3056\u307e\u306a\u6c34\u3068\u30e1\u30bf\u30ce\u30fc\u30eb\u3092\u691c\u67fb\u3057\u307e\u3057\u305f\u300210ppt\u306e\u6a19\u6e96\u6eb6\u6db2\uff08\u8131\u30a4\u30aa\u30f3\uff08DI\uff09\u6c34\uff1aEMSURE\u30e1\u30bf\u30ce\u30fc\u30eb 50\uff1a50\uff09\u3092\u57fa\u6e96\u3068\u3059\u308b\u3068\u3001EMSURE\u30e1\u30bf\u30ce\u30fc\u30eb\uff08\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u5bb9\u5668\u4ed8\u304d\uff09\u304a\u3088\u3073JT Baker\u30e1\u30bf\u30ce\u30fc\u30eb\u306f\u3001TFA\u304c\u691c\u51fa\u53ef\u80fd\u307e\u305f\u306f\u6709\u610f\u306b\u9ad8\u3044\u30ec\u30d9\u30eb\u306e\u4ed6\u306e\u30d6\u30e9\u30f3\u30c9\u3068\u6bd4\u8f03\u3057\u3066\u3001\u306f\u308b\u304b\u306b\u30af\u30ea\u30fc\u30f3\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\uff08<strong>Figure 1<\/strong>\uff09\u3002\u6c34\u8a66\u85ac\u306b\u95a2\u3057\u3066\u306f\u3001Restek\u306e\u65bd\u8a2d\u3067\u751f\u6210\u3055\u308c\u305f\u9006\u6d78\u900f\uff08RO\uff09\u6c34\u3068DI\u6c34\u306f\u3001LC\/MS\u30b0\u30ec\u30fc\u30c9\u306e\u6c34\u3088\u308a\u3082\u306f\u308b\u304b\u306b\u30af\u30ea\u30fc\u30f3\u3067\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1<\/strong>. <strong>\u3000\u6c34\u3068\u30e1\u30bf\u30ce\u30fc\u30eb\u8a66\u85ac\u4e2d\u306eTFA<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-are-you-interested-in-ultrashort-chain-pfas-analysis-be-sure-to-screen-your-solventssolutions-for-contamination-01.png\" alt=\"timeline\" class=\"wp-image-60458\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">TFA\u3092\u542b\u3080PFAS\u5206\u6790\u3092\u884c\u304a\u3046\u3068\u3059\u308b\u5834\u5408\u306f\u3001\u4f7f\u7528\u3057\u3066\u3044\u308b\u8a66\u85ac\u6eb6\u5a92\u306e\u7a2e\u985e\u306b\u6ce8\u610f\u3059\u3079\u304d\u306a\u306e\u304c\u304a\u5206\u304b\u308a\u3067\u3057\u3087\u3046\u3002\u5fae\u91cf\u30ec\u30d9\u30eb\u306eTFA\u691c\u51fa\u306e\u305f\u3081\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3068LC\u5206\u6790\u306e\u4e21\u65b9\u3067\u3001\u3088\u308a\u30af\u30ea\u30fc\u30f3\u306a\u6eb6\u5a92\u3092\u4f7f\u7528\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u30ac\u30e9\u30b9\u88fd\u306eHPLC\u30d0\u30a4\u30a2\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001TFA\u306e\u30b3\u30f3\u30bf\u30df\u304c\u767a\u751f\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u8d85\u77ed\u9396PFAS\u307e\u305f\u306fTFA\u306eLC-MS\/MS\u5206\u6790\u306b\u306f\u3001\u5fae\u91cf\u30ec\u30d9\u30eb\u306e\u30b3\u30f3\u30bf\u30df\u3092\u907f\u3051\u308b\u305f\u3081\u306b\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u88fd\u30d0\u30a4\u30a2\u30eb\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8cb4\u793e\u306e\u30e9\u30dc\u3067\u306fTFA\u3092\u5206\u6790\u3057\u3066\u3044\u307e\u3059\u304b\uff1f\u3069\u306e\u3088\u3046\u306a\u8a66\u85ac\u6eb6\u5a92\u3084\u5b9f\u9a13\u5668\u5177\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u304b\u3001\u305c\u3072\u7d4c\u9a13\u3092\u30b7\u30a7\u30a2\u3057\u3066\u304f\u3060\u3055\u3044\uff01<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u8d85\u77ed\u9396PFAS\u5206\u6790\u306b\u304a\u3051\u308bTFA\u30b3\u30f3\u30bf\u30df\u3092\u907f\u3051\u308b\u305f\u3081\u306e\u6eb6\u5a92\u30fb\u6eb6\u6db2\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u65b9\u6cd5\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002TFA\u304c\u542b\u307e\u308c\u3066\u3044\u306a\u3044\u6700\u9069\u306a\u8a66\u85ac\u6eb6\u5a92\u3084\u5b9f\u9a13\u5668\u5177\u3001TFA\u3092\u542b\u307e\u306a\u3044\u6c34\u8a66\u85ac\u306e\u9078\u3073\u65b9\u3001LC-MS\/MS\u5206\u6790\u3067\u306e\u6700\u826f\u306e\u5b9f\u65bd\u65b9\u6cd5\u306b\u3064\u3044\u3066\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":46,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2760],"industries-application":[2288,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2343],"ppma_author":[578],"class_list":["post-48544","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-environmental-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Shun-Hsin Liang, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/shun-hsin-liang-phd\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":578,"user_id":46,"is_guest":0,"slug":"shun-hsin-liang-phd","display_name":"Shun-Hsin Liang, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-liang-shun-hsin-e1765414149534.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-liang-shun-hsin-e1765414149534.png"},"author_category":"1","first_name":"Shun-Hsin","last_name":"Liang","user_url":"https:\/\/www.linkedin.com\/in\/shun-hsin-liang-174423123\/","job_title":"Senior Principal Scientist, LC Solution","description":"Shun-Hsin is a senior principal scientist in LC Solutions at Restek. He received his bachelor\u2019s degree from the National Taiwan University in 1988 and obtained his PhD from Michigan State University in 1996. He performed postdoctoral research at the University of Michigan from 1996 to 2000 for oncology studies. In 2001, he was appointed as research faculty at The Pennsylvania State University and focused on molecular toxicology research. In 2006, he joined MPI Research Inc. as a senior research scientist and was a study director for GLP analytical projects. In 2013, Dr. Liang joined the LC Solutions department at Restek and specialized in developing application methods across the fields of environmental, food safety, and life sciences."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48544","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/46"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48544"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48544\/revisions"}],"predecessor-version":[{"id":93012,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48544\/revisions\/93012"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48544"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48544"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48544"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48544"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48544"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48544"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48544"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48544"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48544"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}