{"id":48546,"date":"2019-01-21T13:30:00","date_gmt":"2019-01-21T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/sorry-for-the-delay-japan\/"},"modified":"2026-04-15T16:22:02","modified_gmt":"2026-04-15T16:22:02","slug":"sorry-for-the-delay-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4800-ja\/sorry-for-the-delay-japan","title":{"rendered":"PFAS\u5206\u6790\u306b\u5fc5\u9808\u306e\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306e\u91cd\u8981\u6027\u3068\u52b9\u679c"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6642\u3005\u4f3a\u3046\u3001\u9867\u5ba2\u304b\u3089\u306e\u8a00\u8449\u3067\u3059\u3002\u300c\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306e\u5fc5\u8981\u6027\u3092\u611f\u3058\u305f\u3053\u3068\u304c\u306a\u3044\u3002\u306a\u304f\u3066\u3082\u4f55\u306e\u554f\u984c\u3082\u306a\u304b\u3063\u305f\u304b\u3089\u306d\u3002\u300d<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305d\u3093\u306a\u30b1\u30fc\u30b9\u3082\u3042\u308b\u3067\u3057\u3087\u3046\u3002\u4f8b\u3048\u3070\u3001\u9ad8\u6fc3\u5ea6\u3067PFAS\u306b\u6c5a\u67d3\u3055\u308c\u305f\u571f\u58cc\u30b5\u30f3\u30d7\u30eb\u306e\u5834\u5408\u306a\u3069\u306f\u3001\u6700\u7d42\u7684\u306b\u5f97\u3089\u308c\u308b\u7d50\u679c\u306b\u3001PFAS\u306e\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u306b\u3088\u308b\u5e72\u6e09\u306f\u307b\u3068\u3093\u3069\u5f71\u97ff\u3092\u4e0e\u3048\u306a\u3044\u305f\u3081\u3001\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u304c\u306a\u304f\u3066\u3082\u554f\u984c\u306a\u3044\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3057\u304b\u3057\u3001\u3053\u308c\u304b\u3089\u304a\u898b\u305b\u3059\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304b\u3089\u3001\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306e\u6709\u7121\u3067PFAS\u306e\u5206\u6790\u7d50\u679c\u304c\u7570\u306a\u308b\u3068\u77e5\u3063\u305f\u3089\u3001\u3053\u306e\u3088\u3046\u306a\u8a00\u8449\u306f\u51fa\u3066\u3053\u306a\u304f\u306a\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u6bb5\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u3001\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306a\u3057\u3067\u30d6\u30e9\u30f3\u30af\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3057\u305f\u5206\u6790\u7d50\u679c\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u306b\u542b\u307e\u308c\u308b\u5404PFAS\u306f\u60f3\u5b9a\u901a\u308a\u306e\u4fdd\u6301\u6642\u9593\u306b\u92ed\u3044\u5f62\u72b6\u306e\u30d4\u30fc\u30af\u3092\u5f62\u6210\u3057\u3066\u3044\u307e\u3059\u3002\u5404PFAS\u304c\u4f4e\u6fc3\u5ea6\u3067\u30b5\u30f3\u30d7\u30eb\u306b\u542b\u307e\u308c\u3066\u3044\u308b\u5834\u5408\u3001\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306a\u3057\u3067\u306f\u3069\u306e\u3088\u3046\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3068\u306a\u308b\u304b\u60f3\u50cf\u3067\u304d\u307e\u3059\u304b\uff1f<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"526\" height=\"955\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-sorry-for-the-delay.-here-is-your-chromatogram-with-and-without-the-pfas-delay-column-01-JP-suzu.png\" alt=\"\" class=\"wp-image-16833\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-sorry-for-the-delay.-here-is-your-chromatogram-with-and-without-the-pfas-delay-column-01-JP-suzu.png 526w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-sorry-for-the-delay.-here-is-your-chromatogram-with-and-without-the-pfas-delay-column-01-JP-suzu-165x300.png 165w\" sizes=\"auto, (max-width: 526px) 100vw, 526px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"532\" height=\"978\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-sorry-for-the-delay.-here-is-your-chromatogram-with-and-without-the-pfas-delay-column-02-JP-suzu.png\" alt=\"\" class=\"wp-image-16845\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-sorry-for-the-delay.-here-is-your-chromatogram-with-and-without-the-pfas-delay-column-02-JP-suzu.png 532w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-sorry-for-the-delay.-here-is-your-chromatogram-with-and-without-the-pfas-delay-column-02-JP-suzu-163x300.png 163w\" sizes=\"auto, (max-width: 532px) 100vw, 532px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0b\u6bb5\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u3001\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u3042\u308a\u3067\u30d6\u30e9\u30f3\u30af\u30b5\u30f3\u30d7\u30eb\u3092\u6ce8\u5165\u3057\u305f\u5206\u6790\u7d50\u679c\u3067\u3059\u3002\u92ed\u3044\u5f62\u72b6\u306e\u30d4\u30fc\u30af\u304c\u306a\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u304c\u3001\u300c\u9045\u5ef6\u3057\u305f\u30d4\u30fc\u30af\u300d\u306f\u3069\u3053\u306b\u3042\u308b\u304b\u5206\u304b\u308a\u307e\u3059\u304b\uff1f\u76ee\u7684\u5316\u5408\u7269\u306f\u60f3\u5b9a\u3055\u308c\u308b\u4fdd\u6301\u6642\u9593\u306b\u30d4\u30fc\u30af\u3092\u5f62\u6210\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u305d\u306e\u5f8c\u306b\u3042\u308b\u9ad8\u3044\u30b7\u30b0\u30ca\u30eb\u306f\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u3088\u3063\u3066\u4fdd\u6301\u3055\u308c\u305f\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u306e\u3082\u306e\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5fd8\u308c\u306a\u3044\u3067\u9802\u304d\u305f\u3044\u306e\u306f\u3001PFAS\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306fLC-MS\/MS\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306b\u304a\u3044\u3066\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306e\u524d\u306b\u53d6\u308a\u4ed8\u3051\u3089\u308c\u3066\u3044\u308b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u306f\u79fb\u52d5\u76f8\u306e\u30dc\u30c8\u30eb\u304b\u3089\u307e\u305a\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u3092\u901a\u904e\u3057\u3001\u305d\u306e\u5f8c\u5206\u6790\u30ab\u30e9\u30e0\u3001\u691c\u51fa\u5668\u3078\u3068\u6d41\u5165\u3057\u3066\u3044\u304d\u307e\u3059\u3002\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u958b\u59cb\u3059\u308b\u524d\u306b\u5206\u6790\u6210\u5206\u3092\u5206\u6790\u30ab\u30e9\u30e0\u306e\u30d8\u30c3\u30c9\u90e8\u5206\u306b\u51dd\u96c6\u3055\u305b\u308b\u30b5\u30f3\u30d7\u30eb\u306e\u6ce8\u5165\u65b9\u6cd5\u3068\u7570\u306a\u308a\u3001\u5e72\u6e09\u6210\u5206\u306f\u7d99\u7d9a\u7684\u306b\u767a\u751f\u3057\u3001\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u3092\u901a\u904e\u3059\u308b\u969b\u306b\u4fdd\u6301\u3055\u308c\u3001\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u3092\u901a\u904e\u3059\u308b\u9593\u306b\u5e0c\u91c8\u3055\u308c\u3001\u5206\u6790\u30ab\u30e9\u30e0\u3067\u3055\u3089\u306b\u4fdd\u6301\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3069\u306e\u6bb5\u968e\u306b\u304a\u3044\u3066\u3082\u5fc5\u305a\u3057\u3082\u51dd\u96c6\u3055\u308c\u308b\u3053\u3068\u304c\u306a\u3044\u305f\u3081\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306f\u30d6\u30ed\u30fc\u30c9\u306b\u306a\u308a\u3001\u9ad8\u3044\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u30b7\u30b0\u30ca\u30eb\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3054\u89a7\u306e\u901a\u308a\u3001\u9045\u5ef6\u3057\u305f\u5e72\u6e09\u6210\u5206\u306e\u30d4\u30fc\u30af\u306f\u5e83\u304c\u3063\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u308c\u306f\u5e72\u6e09\u6210\u5206\u304c\u30b7\u30b9\u30c6\u30e0\u306b\u7d99\u7d9a\u7684\u306b\u6d41\u5165\u3057\u3066\u3044\u308b\u305f\u3081\u3067\u3059\u3002\u30b7\u30b0\u30ca\u30eb\u306f\u92ed\u3044\u30d4\u30fc\u30af\u3092\u5f62\u6210\u305b\u305a\u3001\u6301\u7d9a\u7684\u306b\u9ad8\u3044\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u3068\u3057\u3066\u73fe\u308c\u307e\u3059\u3002\u306a\u305c\u306a\u3089\u3001\u5e72\u6e09\u6210\u5206\u306f\u5206\u6790\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u5192\u982d\uff08\u79fb\u52d5\u76f8\uff09\u304b\u3089\u5e38\u306b\u5b58\u5728\u3057\u3066\u304a\u308a\u3001\u5206\u6790\u6210\u5206\u306e\u3088\u3046\u306b\u5206\u6790\u30ab\u30e9\u30e0\u306e\u30d8\u30c3\u30c9\u90e8\u5206\u306b\u51dd\u96c6\u3057\u306a\u3044\u304b\u3089\u3067\u3059\u3002\u9045\u5ef6\u3057\u3066\u73fe\u308c\u308b\u30b7\u30b0\u30ca\u30eb\u306e\u5f37\u5ea6\u306f\u3001LC\u30ab\u30e9\u30e0\u306e\u5e73\u8861\u5316\u6642\u9593\u306b\u3088\u3063\u3066\u5927\u304d\u304f\u5909\u308f\u308a\u307e\u3059\u3002\u30ab\u30e9\u30e0\u3092\u5341\u5206\u306b\u5e73\u8861\u5316\u3059\u308b\u3053\u3068\u3067\u3001\u30b7\u30b9\u30c6\u30e0\u5185\u90e8\u306e\u5404\u7a2e\u90e8\u54c1\u304b\u3089\u6eb6\u51fa\u3059\u308b\u5e72\u6e09\u7269\u8cea\u304c\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306b\u4fdd\u6301\u3055\u308c\u308b\u91cf\u304c\u5909\u308f\u308b\u305f\u3081\u3067\u3059\u3002\u307e\u305f\u3001\u4f7f\u7528\u3059\u308bLC-MS\/MS\u30b7\u30b9\u30c6\u30e0\u306e\u69cb\u6210\u90e8\u54c1\u306e\u6750\u8cea\u306b\u3088\u3063\u3066\u3082\u3001\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306e\u5e72\u6e09\u306e\u5ea6\u5408\u3044\u306b\u9055\u3044\u304c\u751f\u3058\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306e\u5e72\u6e09\u3092\u8efd\u6e1b\u3059\u308b\u624b\u6bb5\u3068\u3057\u3066\u306f\u3001PFAS\u304c\u6eb6\u51fa\u3057\u3084\u3059\u3044\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u90e8\u54c1\u3092\u3001PFAS\u306e\u6eb6\u51fa\u304c\u6975\u3081\u3066\u5c11\u306a\u3044PEEK\u88fd\u306a\u3069PFAS\u30d5\u30ea\u30fc\u306e\u90e8\u54c1\u306b\u4ea4\u63db\u3059\u308b\u65b9\u6cd5\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u3057\u304b\u3057\u3001LC-MS\/MS\u30b7\u30b9\u30c6\u30e0\u3054\u3068\u306b\u4ea4\u63db\u304c\u5fc5\u8981\u306a\u90e8\u54c1\u304c\u7570\u306a\u308b\u305f\u3081\u3001\u3053\u306e\u5bfe\u5fdc\u3060\u3051\u3067\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u5e72\u6e09\u3092\u5b8c\u5168\u306b\u6392\u9664\u3059\u308b\u3053\u3068\u306f\u56f0\u96e3\u3067\u3059\u3002\u307e\u305f\u3001\u5168\u30d1\u30fc\u30c4\u306e\u4ea4\u63db\u306b\u306f\u591a\u304f\u306e\u6642\u9593\u3068\u52b4\u529b\u3092\u8981\u3057\u3001\u672a\u77e5\u306e\u5e72\u6e09\u6e90\u306e\u767a\u898b\u3067\u3055\u3089\u306b\u5206\u6790\u304c\u96e3\u822a\u3059\u308b\u53ef\u80fd\u6027\u3082\u5426\u5b9a\u3067\u304d\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9f\u969b\u306ePFAS\u5206\u6790\u3067\u306f\u3001\u8ecd\u7528\u57fa\u5730\u306e\u6c5a\u67d3\u571f\u58cc\u3084\u6d88\u9632\u8a13\u7df4\u5834\u306a\u3069\u3067\u63a1\u53d6\u3055\u308c\u305f\u9ad8\u6fc3\u5ea6\u30b5\u30f3\u30d7\u30eb\u3092\u6271\u3046\u30b1\u30fc\u30b9\u3068\u3001\u98f2\u6599\u6c34\u306a\u3069\u6975\u3081\u3066\u4f4e\u6fc3\u5ea6\uff08ppt\u30ec\u30d9\u30eb\u307e\u305f\u306f\u305d\u308c\u4ee5\u4e0b\uff09\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u691c\u51fa\u304c\u5fc5\u8981\u306a\u30b1\u30fc\u30b9\u304c\u6df7\u5728\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f7f\u7528\u3059\u308bLC-MS\/MS\u30b7\u30b9\u30c6\u30e0\u3084\u6271\u3046\u30b5\u30f3\u30d7\u30eb\u6fc3\u5ea6\u30ec\u30d9\u30eb\u306b\u95a2\u308f\u3089\u305a\u3001\u5206\u6790\u306e\u4fe1\u983c\u6027\u5411\u4e0a\u3068\u4f5c\u696d\u52b9\u7387\u306e\u89b3\u70b9\u304b\u3089\u3001\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u306e\u524d\u3001\u3064\u307e\u308a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u5192\u982d\u306bPFAS\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u3092\u53d6\u308a\u4ed8\u3051\u308b\u3053\u3068\u304c\u6709\u76ca\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u304a\u3088\u3073\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u306e\u6bb5\u968e\u3001\u3055\u3089\u306b\u65e5\u3005\u306e\u5206\u6790\u696d\u52d9\u306b\u304a\u3044\u3066\u3001\u4e0d\u5fc5\u8981\u306a\u5e72\u6e09\u30c8\u30e9\u30d6\u30eb\u306e\u8efd\u6e1b\u3068\u5b89\u5b9a\u3057\u305f\u7d50\u679c\u53d6\u5f97\u304c\u671f\u5f85\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Sometimes I hear this from customers: I don&#8217;t need a delay column. I haven&#8217;t had any trouble without it so far.&#8221; It might be true. You may not have any issues without the delay column, especially when your samples are,&#8230;<\/p>\n<p>&#8220;<\/p>\n","protected":false},"author":65,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2760],"industries-application":[2288,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2365,2343,2345],"ppma_author":[601],"class_list":["post-48546","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-environmental-ja","resource-technique-ms-ms-ja","resource-technique-liquid-chromatography-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"SaVanna Cano","author_link":"https:\/\/discover.restek.com\/ja\/author\/savanna-cano\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":601,"user_id":0,"is_guest":1,"slug":"mike-chang","display_name":"Mike Chang","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-square-chang-mike.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-square-chang-mike.jpg"},"author_category":"1","first_name":"Mike","last_name":"Chang","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48546","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/65"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48546"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48546\/revisions"}],"predecessor-version":[{"id":93014,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48546\/revisions\/93014"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48546"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48546"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48546"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48546"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48546"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48546"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48546"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48546"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48546"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}