{"id":48547,"date":"2020-04-16T14:30:00","date_gmt":"2020-04-16T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/are-pfas-sticking-in-your-system-japan\/"},"modified":"2026-04-15T16:24:22","modified_gmt":"2026-04-15T16:24:22","slug":"are-pfas-sticking-in-your-system-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4582-ja\/are-pfas-sticking-in-your-system-japan","title":{"rendered":"PFAS\u5206\u6790\u306e\u30af\u30ed\u30b9\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u9632\u6b62\u30ac\u30a4\u30c9\uff1a\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u304b\u3089\u6eb6\u5a92\u306e\u53d6\u308a\u6271\u3044\u307e\u3067"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.epa.gov\/pfas\" target=\"_blank\" rel=\"noreferrer noopener\">\u30da\u30eb\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269<\/a>\uff08PFAS\uff09\u306f\u3001\u74b0\u5883\u3084\u4eba\u4f53\u3001\u52d5\u7269\u306b\u81f3\u308b\u307e\u3067\u3001\u5e83\u7bc4\u56f2\u306b\u5b58\u5728\u3057\u307e\u3059\u3002\u52a0\u3048\u3066PFAS\u306f\u6b8b\u7559\u6027\u3092\u6301\u3061\u3001\u84c4\u7a4d\u3055\u308c\u308b\u53ef\u80fd\u6027\u3082\u9ad8\u3044\u305f\u3081\u3001\u591a\u304f\u306e\u898f\u5b9a\u306b\u6cbf\u3063\u305f\u53b3\u683c\u306a\u76e3\u8996\u3068\u8a55\u4fa1\u304c\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002PFAS\u306f\u30b5\u30f3\u30d7\u30eb\u3084\u30b7\u30b9\u30c6\u30e0\u306b\u3082\u6df7\u5165\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u5206\u6790\u7d50\u679c\u306b\u304a\u3044\u3066\u610f\u56f3\u3057\u306a\u3044\u6c5a\u67d3\uff08\u30b3\u30f3\u30bf\u30df\uff09\u3092\u5f15\u304d\u8d77\u3053\u3057\u3001\u6642\u306b\u507d\u967d\u6027\u3092\u751f\u3058\u3055\u305b\u308b\u539f\u56e0\u3068\u306a\u308b\u3053\u3068\u3082\u5c11\u306a\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u3067\u306f\u3001PFAS\u306f\u3069\u3053\u306b\u5b58\u5728\u3057\u3066\u3044\u308b\u306e\u3067\u3057\u3087\u3046\uff1f\u6700\u3082\u898b\u843d\u3068\u3057\u304c\u3061\u306a\u30b3\u30f3\u30bf\u30df\u306e\u767a\u751f\u6e90\u3068\u306f\uff1f\u3069\u3046\u3059\u308c\u3070\u507d\u967d\u6027\u306f\u9632\u3052\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">PFAS\u30b3\u30f3\u30bf\u30df\u306e\u767a\u751f\u6e90\u3092\u7279\u5b9a\u3059\u308b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u306b\u3088\u308b\u4ea4\u5dee\u6c5a\u67d3\uff08\u30af\u30ed\u30b9\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\uff09\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u304b\u3089\u5206\u6790\u7d50\u679c\u306b\u81f3\u308b\u307e\u3067\u306e\u5404\u30d7\u30ed\u30bb\u30b9\u306b\u304a\u3044\u3066\u767a\u751f\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u53d6\u308a\u6271\u3044\u65b9\u3084\u5206\u6790\u88c5\u7f6e\u306b\u4f7f\u308f\u308c\u308b\u90e8\u54c1\u7d20\u6750\u306b\u3082\u6ce8\u610f\u3092\u6255\u3046\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u304cPFAS\u3092\u542b\u3080\u3001\u307e\u305f\u306f\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3055\u308c\u305f\u7d20\u6750\u306b\u4e00\u5207\u89e6\u308c\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u3053\u3068\u304c\u3001\u6c5a\u67d3\u3092\u9632\u3050\u7b2c\u4e00\u6b69\u3067\u3059\u3002\u5404\u30b9\u30c6\u30c3\u30d7\u306e\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u3092\u7d30\u304b\u304f\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u6642\u306e\u6ce8\u610f\u70b9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u25a0\u907f\u3051\u308b\u3079\u304d\u88fd\u54c1\uff1a<br>\u30fb \u4f4e\u5bc6\u5ea6\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\uff08LDPE\uff09\u30dc\u30c8\u30eb\u3001\u30dd\u30ea\u30c6\u30c8\u30e9\u30d5\u30eb\u30aa\u30ed\u30a8\u30c1\u30ec\u30f3\uff08PTFE\uff09\u3092\u542b\u3080\u8863\u985e\uff08\u64a5\u6c34\u52a0\u5de5\u3055\u308c\u305f\u670d\u3084\u9632\u6c34\u30b3\u30fc\u30c8\u306a\u3069\uff09<br>\u30fb \u9632\u6c34\u30ce\u30fc\u30c8\u3001\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u88fd\u30af\u30ea\u30c3\u30d7\u30dc\u30fc\u30c9\u3001\u8cbc\u308a\u4ed8\u3051\u5f0f\u30e1\u30e2\u30d1\u30c3\u30c9\u3001\u6cb9\u6027\u30de\u30fc\u30ab\u30fc\u3001\u518d\u5229\u7528\u53ef\u80fd\u306a\u30a2\u30a4\u30b9\u30d1\u30c3\u30af\uff08\u30d6\u30eb\u30fc\u30a2\u30a4\u30b9\uff09\u306a\u3069<br>\u25a0\u63a8\u5968\u4e8b\u9805\uff1a<br>\u30fb \u9ad8\u5bc6\u5ea6\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\uff08HDPE\uff09\u88fd\u3084\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u88fd\u30dc\u30c8\u30eb\u3092\u4f7f\u7528\u3057\u305f\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0<br>\u30fb \u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u5f8c\u306b\u3001\u30e9\u30d9\u30eb\u306e\u8cbc\u4ed8\uff08\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u524d\u306b\u30e9\u30d9\u30eb\u3092\u6dfb\u4ed8\u3057\u306a\u3044\uff09<br>\u30fb \u53ef\u80fd\u3067\u3042\u308c\u3070\u3001\u4e8b\u524d\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3055\u308c\u305f\u30dc\u30c8\u30eb\u306e\u4f7f\u7528<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3067\u306e\u6ce8\u610f\u70b9<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u306f\u3001\u30ac\u30e9\u30b9\u5bb9\u5668\u306b\u9577\u6642\u9593\u63a5\u89e6\u3059\u308b\u3053\u3068\u3067\u5438\u7740\u3059\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306b\u4f7f\u7528\u3059\u308b\u5bb9\u5668\u3084\u5668\u5177\u306b\u306f\u7d30\u5fc3\u306e\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25a0\u907f\u3051\u308b\u3079\u304d\u88fd\u54c1\uff1a<br>\u30fb \u30ac\u30e9\u30b9\u88fd\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30d4\u30da\u30c3\u30c8\u3001PTFE\u30b7\u30fc\u30eb\u4ed8\u304d\u30d0\u30a4\u30a2\u30eb\u30ad\u30e3\u30c3\u30d7\u3001\u4e00\u90e8\u306e\u30ac\u30e9\u30b9\u88fdHPLC\u30d0\u30a4\u30a2\u30eb\u306a\u3069<br>\u30fb \u30a2\u30eb\u30df\u30db\u30a4\u30eb\uff08\u30ce\u30f3\u30b9\u30c6\u30a3\u30c3\u30af\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3055\u308c\u3066\u3044\u308b\u305f\u3081\uff09<br>\u30fb \u65e5\u713c\u3051\u6b62\u3081\uff0f\u9632\u866b\u5264\u3001\u67d4\u8edf\u5264\u3001\u4fdd\u6e7f\u5264\u3001\u9632\u6c5a\u52a0\u5de5\u3055\u308c\u305f\u767d\u8863<br>\u30fb PFAS\u30d5\u30ea\u30fc\u304c\u78ba\u8a8d\u3067\u304d\u3066\u3044\u306a\u3044\u6d17\u6d44\u5264\u3092\u7528\u3044\u305f\u30ac\u30e9\u30b9\u5668\u5177\u6d17\u6d44<br>\u25a0\u63a8\u5968\u4e8b\u9805\uff1a<br>\u30fb\u30b4\u30e0\u3001\u30dd\u30ea\u5869\u5316\u30d3\u30cb\u30eb\uff08PVC\uff09\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u3001\u30dd\u30ea\u30a6\u30ec\u30bf\u30f3\u306a\u3069\u306e\u7d20\u6750\u3067\u4f5c\u3089\u308c\u305f\u5668\u5177\u306e\u4f7f\u7528<br>\u30fb\u7dbf\u88fd\u306e\u767d\u8863\u3001\u30cb\u30c8\u30ea\u30eb\u88fd\u624b\u888b\u306e\u7740\u7528<br>\u30fb\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u88fdHPLC\u30d0\u30a4\u30a2\u30eb\u3001\u30ad\u30e3\u30c3\u30d7(Cat.#: 23244)\u3001\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u88fd\u4f7f\u3044\u6368\u3066\u30d4\u30da\u30c3\u30c8\u30c1\u30c3\u30d7\u306e\u4f7f\u7528<br>\u30fb\u624b\u6d17\u3044\u306b\u3088\u308b\u30ac\u30e9\u30b9\u5668\u5177\u6d17\u6d44<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">SPE\u30de\u30cb\u30db\u30fc\u30eb\u30c9\u3092\u4f7f\u7528\u3059\u308b\u3059\u3079\u3066\u306e\u524d\u51e6\u7406\u306b\u5171\u901a\u3059\u308b\u3053\u3068\u3067\u3059\u304c\u3001\u30af\u30ed\u30b9\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u3092\u9632\u3050\u305f\u3081\u306b\u3001\u524d\u51e6\u7406\u304c\u7d42\u4e86\u3057\u305f\u3089\u3001\u518d\u5229\u7528\u3059\u308b\u90e8\u54c1\u306f\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3067\u6d17\u6d44\u3057\u3001\u7d0410\u5206\u9593\u8d85\u97f3\u6ce2\u51e6\u7406\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u5206\u6790\u88c5\u7f6e\u306b\u304a\u3051\u308bPFAS\u306e\u5f71\u97ff<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u4f7f\u7528\u3059\u308b\u88c5\u7f6e\u306b\u3082PFAS\u306e\u5f71\u97ff\u304c\u53ca\u3076\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u7279\u306b\u3001\u30dd\u30ea\u30c6\u30c8\u30e9\u30d5\u30eb\u30aa\u30ed\u30a8\u30c1\u30ec\u30f3\uff08PTFE\uff09\u88fd\u306e\u90e8\u54c1\u304c\u88c5\u7f6e\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u3001\u305d\u306e\u6b8b\u7559\u7269\u304c\u7d50\u679c\u306b\u60aa\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u25a0\u6ce8\u610f\u70b9\uff1a<br>\u30fb\u3059\u3079\u3066\u306ePTFE\u30c1\u30e5\u30fc\u30d6\u3001PTFE\u30d5\u30ea\u30c3\u30c8\u3001\u7279\u5b9a\u306e\u30ed\u30fc\u30bf\u30fc\u30b7\u30fc\u30eb\u3084\u30b9\u30c6\u30fc\u30bf\u30fc\u9762\u306e\u3042\u308b\u30b5\u30f3\u30d7\u30eb\u30d0\u30eb\u30d6\u306e\u4f7f\u7528\u3092\u907f\u3051\u308b<br>\u30fbLC-MS\/MS\u30b7\u30b9\u30c6\u30e0\u304c\u9577\u6642\u9593\u653e\u7f6e\u3055\u308c\u3066\u3044\u305f\u5834\u5408\u3001\u6b8b\u7559PFAS\u306e\u84c4\u7a4d\u304c\u539f\u56e0\u3067\u3001\u6700\u521d\u306e\u6ce8\u5165\u3067\u9ad8\u6fc3\u5ea6\u306ePFAS\u304c\u691c\u51fa\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u5e72\u6e09\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u305f\u3081\u306b\u3001\u30b7\u30b9\u30c6\u30e0\u306e\u30c1\u30e5\u30fc\u30d6\u3092\u30dd\u30ea\u30a8\u30fc\u30c6\u30eb\u30a8\u30fc\u30c6\u30eb\u30b1\u30c8\u30f3\uff08PEEK\uff09\u30c1\u30e5\u30fc\u30d6\u3084\u30b9\u30c6\u30f3\u30ec\u30b9\u30b9\u30c1\u30fc\u30eb\u306b\uff08\u30b3\u30b9\u30c8\u304c\u9ad8\u304f\u73fe\u5b9f\u7684\u3067\u306f\u306a\u3044\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u304c\u3001\u5404\u793e\u304c\u51fa\u3057\u3066\u3044\u308bPFAS\u5206\u6790\u306b\u7279\u5316\u3057\u305f\u30ad\u30c3\u30c8\u3092\u4f7f\u7528\u3057\u3066\uff09\u4ea4\u63db\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30df\u30ad\u30b7\u30f3\u30b0\u30c1\u30e3\u30f3\u30d0\u30fc\u306e\u5f8c\u306bPFAS\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0(Cat.#: 27854)\u3092\u8ffd\u52a0\u3057\u3066\u3001\u30b7\u30b9\u30c6\u30e0\u306b\u95a2\u9023\u3059\u308bPFAS\u3092\u30c8\u30e9\u30c3\u30d7\u3059\u308b\u306e\u3082\u826f\u3044\u65b9\u6cd5\u3067\u3059\u3002\u5206\u6790\u3092\u958b\u59cb\u3059\u308b\u524d\u306b\u3001\u5206\u6790\u30ab\u30e9\u30e0\uff08US EPA 533, US EPA 537.1, ISO 21675:2019, ASTM D7968-17A, ASTM D7979-19, DIN 38407-42\u7b49\u306e\u30e1\u30bd\u30c3\u30c9\u7528\u306eRaptor C18, (Cat.#: 9304A52)\uff09\u309220-30\u30ab\u30e9\u30e0\u5bb9\u91cf\u3067\u5e73\u8861\u5316\u3057\u3001\u5b9f\u969b\u306e\u5206\u6790\u6761\u4ef6\u3092\u7528\u3044\u3066\u6709\u6a5f\u6eb6\u5a92\uff08\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\uff09\u30923\uff5e4\u56de\u6ce8\u5165\u3057\u3001\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u30fc\u306b\u6b8b\u7559\u3057\u3066\u3044\u308bPFAS\u3092\u6d17\u3044\u6d41\u3057\u3066\u304f\u3060\u3055\u3044\u3002<br>\u25a0\u53c2\u7167\u60c5\u5831\uff1a<br>\u30fb\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066\u306f\u3001\u30d3\u30c7\u30aa\u300c<a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/evav3628-ja\/pfas-analysis-why-a-delay-column-is-important-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/evav3628-ja\/pfas-analysis-why-a-delay-column-is-important-japan\" rel=\"noreferrer noopener\">PFAS\u5206\u6790\u306b\u304a\u3051\u308b\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u306e\u91cd\u8981\u6027\u3068\u305d\u306e\u52b9\u679c\u30fcPFAS\u6c5a\u67d3\u7ba1\u7406<\/a>\u300d\u3068\u30d6\u30ed\u30b0\u300c<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar3001-ja\/japanese-eliminate-the-impact-of-instrument-related-pfas-interferences-by-using-a-delay-column\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar3001-ja\/japanese-eliminate-the-impact-of-instrument-related-pfas-interferences-by-using-a-delay-column\" rel=\"noreferrer noopener\">\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u30b7\u30b9\u30c6\u30e0\u7531\u6765\u306ePFAS\u306b\u3088\u308b\u59a8\u5bb3\u9664\u53bb<\/a>\u300d\u3082\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<br>\u30fb\u30ab\u30e9\u30e0\u9078\u629e\u306b\u3064\u3044\u3066\u306f\u3001\u300c<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar3069-ja\/japanese-pfas-lc-column-anatomy-which-phase-dimensions-and-particle-type-are-best\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar3069-ja\/japanese-pfas-lc-column-anatomy-which-phase-dimensions-and-particle-type-are-best\" rel=\"noreferrer noopener\">PFAS\u5206\u6790\u7528\u306eLC \u30ab\u30e9\u30e0\u306b\u306f\u3001\u3069\u306e\u56fa\u5b9a\u76f8\u3001\u30b5\u30a4\u30ba\u3001\u7c92\u5b50\u5f84\u304c\u6700\u9069\u304b\uff1f<\/a>\u300d\u306e\u8a18\u4e8b\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e0a\u8a18\u4ee5\u5916\u306ePFAS\u5206\u6790\u306b\u95a2\u3059\u308b\u60c5\u5831\u306f\u3001<a href=\"https:\/\/www.restek.com\/PFAS-JP\" target=\"_blank\" rel=\"noreferrer noopener\">www.restek.com\/PFAS-JP<\/a>\u304b\u3089\u78ba\u8a8d\u3067\u304d\u307e\u3059\uff01<\/h3>\n\n\n\n<h2 class=\"wp-block-heading\">\u6eb6\u5a92\u306e\u53d6\u308a\u6271\u3044\u3068PFAS\u30b3\u30f3\u30bf\u30df\u9632\u6b62<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u898b\u843d\u3068\u3055\u308c\u304c\u3061\u306aPFAS\u30b3\u30f3\u30bf\u30df\u3068\u3057\u3066\u3001\u4f7f\u7528\u3059\u308b\u6eb6\u5a92\u3084\u79fb\u52d5\u76f8\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u79fb\u52d5\u76f8\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u6c34\u3084\u6709\u6a5f\u6eb6\u5a92\u304cPFAS\u3067\u6c5a\u67d3\u3055\u308c\u3066\u3044\u306a\u3044\u304b\u3001\u4e8b\u524d\u306b\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3092\u884c\u3046\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002<br>\u25a0\u6ce8\u610f\u70b9\uff1a<br>\u30fbHPLC\u3084LC-MS\/MS\u30b0\u30ec\u30fc\u30c9\u306e\u79fb\u52d5\u76f8\uff08\u6c34\u3001\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\uff09\u306f\u3001\u88fd\u9020\u6642\u306bPTFE\u30d5\u30a3\u30eb\u30bf\u30fc\u304c\u4f7f\u7528\u3055\u308c\u308b\u3053\u3068\u304c\u591a\u3044<br>\u30fb\u30dc\u30c8\u30eb\u30ad\u30e3\u30c3\u30d7\u306bPTFE\u30e9\u30a4\u30cb\u30f3\u30b0\u304c\u65bd\u3055\u308c\u3066\u3044\u308b\u5834\u5408\u3082\u3042\u308b<br>\u30fb\u5fae\u91cf\u306ePFAS\u30b3\u30f3\u30bf\u30df\u3092\u542b\u3080\u79fb\u52d5\u76f8\u306b\u304a\u3044\u3066\u3082\u3001Type 1\u6c34\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u5b89\u5b9a\u3057\u305f\u5206\u6790\u304c\u53ef\u80fd<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3055\u3089\u306b\u3001\u5206\u6790\u30b7\u30b9\u30c6\u30e0\u306b\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0\uff08Cat.#:&nbsp;27854\uff09\u3092\u8a2d\u7f6e\u3059\u308b\u3053\u3068\u3067\u3001\u79fb\u52d5\u76f8\u3078\u306e\u5f71\u97ff\u3092\u6291\u3048\u308b\u52b9\u679c\u304c\u671f\u5f85\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u8a66\u6599\u8abf\u88fd\u306b\u4f7f\u7528\u3059\u308b\u6eb6\u5a92\u306b\u3064\u3044\u3066\u3082\u3001\u30b5\u30f3\u30d7\u30eb\u30d6\u30e9\u30f3\u30af\u3084\u30d5\u30a3\u30fc\u30eb\u30c9\u30d6\u30e9\u30f3\u30af\u3092\u542b\u3081\u3001\u4e8b\u524d\u306b\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\u6709\u7121\u306e\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u304c\u91cd\u8981\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u52b9\u679c\u7684\u306aPFAS\u5206\u6790\u306e\u305f\u3081\u306e\u6700\u9069\u306a\u5b9f\u8df5<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u5206\u6790\u306b\u304a\u3044\u3066\u6700\u3082\u91cd\u8981\u306a\u306e\u306f\u3001\u3059\u3079\u3066\u306e\u6d88\u8017\u54c1\u3001\u30b7\u30b9\u30c6\u30e0\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u89e6\u308c\u308b\u7d20\u6750\u304cPFAS\u3092\u542b\u307e\u306a\u3044\u304b\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u65b0\u3057\u3044\u90e8\u54c1\u3084\u6eb6\u5a92\u3092\u5c0e\u5165\u3059\u308b\u969b\u306b\u306f\u3001\u305d\u306e\u90fd\u5ea6PFAS\u304c\u542b\u307e\u308c\u3066\u3044\u306a\u3044\u304b\u3069\u3046\u304b\u3092\u30c6\u30b9\u30c8\u3057\u3001\u5e38\u306b\u9069\u5207\u306a\u30e9\u30dc\u30d7\u30e9\u30af\u30c6\u30a3\u30b9\u3092\u5b88\u308b\u3053\u3068\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                \u30ab\u30bf\u30ed\u30b0No. 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS\u5206\u6790\uff5c\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0, 5 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23244\">                                \u30ab\u30bf\u30ed\u30b0No. 23244                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">2.0 mL, 9 mm Solid-Top Polyethylene Caps, Screw-Thread, 10 mil thick membrane, Clear, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23244\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A52\">                                \u30ab\u30bf\u30ed\u30b0No. 9304A52                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 2.7 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304A52\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p><span data-teams=true\">PFAS\u5206\u6790\u306b\u304a\u3051\u308b\u30b3\u30f3\u30bf\u30df\u30e1\u30fc\u30b7\u30e7\u30f3\u3092\u9632\u3050\u3053\u3068\u306f\u3001\u6b63\u78ba\u3067\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5206\u6790\u7d50\u679c\u3092\u5f97\u308b\u305f\u3081\u306b\u975e\u5e38\u306b\u91cd\u8981\u3067\u3059\u3002\u672c\u30ac\u30a4\u30c9\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u304b\u3089\u524d\u51e6\u7406\u3001\u4f7f\u7528\u5206\u6790\u88c5\u7f6e\u3001\u6eb6\u5a92\u306e\u53d6\u308a\u6271\u3044\u306b\u81f3\u308b\u307e\u3067\u3001PFAS\u30b3\u30f3\u30bf\u30df\u306e\u767a\u751f\u6e90\u306b\u95a2\u3059\u308b\u6ce8\u610f\u70b9\u3068\u3001\u305d\u308c\u3092\u9632\u3050\u305f\u3081\u306e\u5b9f\u8df5\u7684\u306a\u65b9\u6cd5\u3092\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002<\/span><\/p>\n<p>&#8220;<\/p>\n","protected":false},"author":33,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2760],"industries-application":[2288,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2343,2345],"ppma_author":[453],"class_list":["post-48547","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-environmental-ja","resource-technique-liquid-chromatography-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Gary Oden","author_link":"https:\/\/discover.restek.com\/ja\/author\/gary-oden\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":453,"user_id":33,"is_guest":0,"slug":"gary-oden","display_name":"Gary Oden","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-oden-gary.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-oden-gary.jpg"},"author_category":"1","first_name":"Gary","last_name":"Oden","user_url":"https:\/\/www.linkedin.com\/in\/gary-oden-jr-a35ba74b\/","job_title":"Technical Service, Specialist I","description":"Gary has 20 years of hands-on experience with chromatography, including SPE, HPLC, and LC\/MS instrumentation. He began his chromatography career in the laboratory as a bonding chemist and has served as a study director for PFAS analysis, specializing in both bioanalytical and environmental fields. His work in developing HPLC and LC\/MS-MS applications has further broadened his expertise in chromatography. Since 2018, Gary has been a key member of Restek\u2019s European-based technical support team, where he offers expert assistance to customers in overcoming complex analytical challenges."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48547","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/33"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48547"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48547\/revisions"}],"predecessor-version":[{"id":93015,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48547\/revisions\/93015"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48547"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48547"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48547"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48547"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48547"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48547"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48547"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48547"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48547"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}