{"id":48548,"date":"2022-10-25T14:30:00","date_gmt":"2022-10-25T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/pfas-contamination-the-neverending-story-japan\/"},"modified":"2026-04-28T19:39:21","modified_gmt":"2026-04-28T19:39:21","slug":"pfas-contamination-the-neverending-story-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4766-ja\/pfas-contamination-the-neverending-story-japan","title":{"rendered":"PFAS\u5206\u6790\u306e\u8ab2\u984c\uff5e\u898b\u3048\u306a\u3044\u6c5a\u67d3\u6e90\u5bfe\u7b56\u306e\u6700\u524d\u7dda"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">PFAS\u5206\u6790\u306b\u304a\u3051\u308b\u6700\u5927\u306e\u8ab2\u984c\uff1a\u898b\u3048\u306a\u3044\u6c5a\u67d3\u6e90\u3068\u306e\u7d42\u308f\u308a\u306a\u304d\u6226\u3044<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u5206\u6790\u3092\u96e3\u3057\u304f\u3057\u3066\u3044\u308b\u306e\u306f\u3001PFAS\u5316\u5408\u7269\u306e\u5e83\u7bc4\u306a\u5b58\u5728\u306b\u8d77\u56e0\u3059\u308b\u3001\u6f5c\u5728\u7684\u306aPFAS\u6c5a\u67d3\u6e90\u306e\u591a\u7a2e\u591a\u69d8\u3055\u3067\u3059\u3002\u305f\u3068\u3048\u3070\u2026<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u591a\u304f\u306e\u6eb6\u5264\u306e\u6ffe\u904e\u306b\u306f\u88fd\u9020\u5de5\u7a0b\u3067PFAS\u304c\u526f\u751f\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308bPTFE\u30d5\u30a3\u30eb\u30bf\u30fc\u3092\u4f7f\u7528<\/li>\n\n\n\n<li>\u30b5\u30f3\u30d7\u30eb\u4fdd\u7ba1\u5bb9\u5668\u306e\u30ad\u30e3\u30c3\u30d7\u3082PTFE\u3067\u88cf\u6253\u3061\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u591a\u3044<\/li>\n\n\n\n<li>\u8d85\u7d14\u6c34\u30b7\u30b9\u30c6\u30e0\u306e\u6a39\u8102\u30d9\u30c3\u30c9\u306f\u5b89\u5b9a\u6027\u306e\u3042\u308b\u9ad8\u5206\u5b50PFAS\u3067\u3042\u308b\u30d5\u30eb\u30aa\u30ed\u30dd\u30ea\u30de\u30fc\u542b\u6709\u306e\u53ef\u80fd\u6027\u3042\u308a<\/li>\n\n\n\n<li>\u30d7\u30e9\u30b9\u30c1\u30c3\u30af\u5bb9\u5668\u306e\u6210\u5f62\u6642\u306b\u4f7f\u7528\u3059\u308b\u96e2\u578b\u5264\u306f\u30d5\u30eb\u30aa\u30ed\u30dd\u30ea\u30de\u30fc\u7cfb\u5316\u5408\u7269\u3092\u542b\u6709<\/li>\n\n\n\n<li>\u30e9\u30dc\u3067\u7740\u7528\u3059\u308b\u767d\u8863\u306b\u65bd\u3059\u9632\u6c5a\u9632\u6c34\u304a\u3088\u3073\u8010\u85ac\u54c1\u6027\u51e6\u7406\u306e\u305f\u3081\u306bPFAS\u5316\u5408\u7269\u3092\u4f7f\u7528<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3046\u3057\u305f\u6c5a\u67d3\u6e90\u306e\u7a2e\u985e\u306f\u81a8\u5927\u3067\u3001\u4e00\u3064\u4e00\u3064\u6319\u3052\u3066\u3044\u3066\u306f\u304d\u308a\u304c\u3042\u308a\u307e\u305b\u3093\u3002\u3053\u306e\u3088\u3046\u306a\u74b0\u5883\u4e0b\u3067\u3001\u7279\u306b\u98f2\u6599\u6c34\u4e2d\u306e\u5fae\u91cf\uff08\u4f4e\u6fc3\u5ea6\uff09PFAS\u5206\u6790\u3067\u306f\u3001\u3069\u308c\u3060\u3051\u74b0\u5883\u7531\u6765\u306e\u6c5a\u67d3\u3092\u6291\u3048\u8fbc\u3081\u308b\u304b\u304c\u30e9\u30dc\u306b\u3068\u3063\u3066\u6975\u3081\u3066\u5927\u304d\u306a\u8ab2\u984c\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">EPA Method\u6e96\u62e0\uff1a\u73fe\u5b9f\u7684\u306a\u5831\u544a\u9650\u754c\uff08MRL\uff09\u3068\u30d6\u30e9\u30f3\u30af\u30ec\u30d9\u30eb\u306e\u7ba1\u7406<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3055\u3089\u306b\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u304c\u8ab2\u3057\u3066\u3044\u308b\u57fa\u6e96\u3082\u30e9\u30dc\u306b\u3068\u3063\u3066\u8ab2\u984c\u3068\u306a\u308a\u307e\u3059\u3002\u7c73\u56fd\u74b0\u5883\u4fdd\u8b77\u5e81\uff08EPA\uff09\u5236\u5b9a\u306eMethod 537.1\u304a\u3088\u3073533\u3067\u306f\u3001\u30d6\u30e9\u30f3\u30af\u4e2d\u306ePFAS\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u6fc3\u5ea6\u306f\u3001\u5404\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306e\u6700\u5c0f\u5831\u544a\u9650\u754c\uff08MRL\uff09\u306e3\u5206\u306e1\u672a\u6e80\u3067\u306a\u3051\u308c\u3070\u306a\u3089\u306a\u3044\u3068\u3044\u3046\u53b3\u3057\u3044\u8981\u4ef6\u304c\u793a\u3055\u308c\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002Restek\u306eGary Oden\u3068Mike Chang\u306f\u3001\u9ad8\u6fc3\u5ea6\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u3078\u306e\u5e72\u6e09\u306e\u53ef\u80fd\u6027\u306b\u3064\u3044\u3066\u53d6\u308a\u4e0a\u3052\u3001Method 537.1\u306b\u6e96\u62e0\u3057\u305f\u300cPFAS\u975e\u542b\u6709\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u300d\u306b\u95a2\u3059\u308b\u30a2\u30c9\u30d0\u30a4\u30b9\u3092\u6587\u732e\u306b\u307e\u3068\u3081\u307e\u3057\u305f\u3002\u305f\u3060\u3057\u3001PFAS\u306e\u5e83\u7bc4\u56f2\u306a\u6c5a\u67d3\u306f\u30e9\u30dc\u306b\u3068\u3063\u3066\u3001\u4f9d\u7136\u3068\u3057\u3066\u8ab2\u984c\u3067\u3042\u308b\u3053\u3068\u306b\u5909\u308f\u308a\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u6c5a\u67d3\u306e\u60f3\u5b9a\u3057\u3066\u3044\u306a\u304b\u3063\u305f\u5909\u8abf<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u307e\u3067\u79c1\u306f\u3001\u6bd4\u8f03\u7684\u904b\u304c\u826f\u304b\u3063\u305f\u306e\u304b\u3001\u5e38\u306b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306b\u73fe\u308c\u308b PFAS \u5316\u5408\u7269\u306f\u4e00\u7a2e\u985e\u3001\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u30d6\u30bf\u30f3\u9178\uff08PFBA\uff09\u3060\u3051\u3067\u3057\u305f\u3002EPA Method 533\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308bPFBA\u306e\u6700\u4f4e\u6fc3\u5ea6\u306e\u6700\u5c0f\u5831\u544a\u9650\u754c\uff08LCMRL\uff09\u306e\u4e00\u4f8b\u306f13 ng\/mL\u3067\u3059\u3002MRL\u3092\u3053\u306e\u5024\u3068\u540c\u7b49\u306b\u8a2d\u5b9a\u3057\u3066\u3044\u308b\u30e9\u30dc\u306a\u3089\u3001\u8a31\u5bb9\u53ef\u80fd\u306aPFBA\u306e\u30d6\u30e9\u30f3\u30af\u6fc3\u5ea6\u306f\u6700\u5927\u30674.3 ng\/m\u3068\u306a\u308a\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\u5bb9\u91cf\u3092250 mL\u3001\u62bd\u51fa\u5f8c\u306e\u6700\u7d42\u91cf\u30921 mL\u3068\u4eee\u5b9a\u3057\u305f\u5834\u5408\u3001\u88c5\u7f6e\u3067\u691c\u51fa\u3055\u308c\u308b\u30d6\u30e9\u30f3\u30af\u6fc3\u5ea6\u306f\u6700\u5927\u30671.08 \u00b5g\/mL\u3067\u3059\u3002<br>\u5b9f\u969b\u306e\u6e2c\u5b9a\u5024\u306f\u3001\u4f7f\u7528\u3057\u305f\u524d\u51e6\u7406\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u306e\u30ed\u30c3\u30c81\u3067\u306f0.36 \u00b5g\/mL\u3001\u30ed\u30c3\u30c82\u3067\u306f0.54 \u00b5g\/mL\u3068\u3001\u3053\u306e\u8a31\u5bb9\u53ef\u80fd\u306a\u30d6\u30e9\u30f3\u30af\u6fc3\u5ea6\u3092\u4e0b\u56de\u3063\u3066\u3044\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u5f8c\u65e5\u3001\u30ed\u30c3\u30c81\u3092\u518d\u691c\u67fb\u3057\u305f\u3068\u3053\u308d\u3001PFBA\u304c4.8 \u00b5g\/mL\u3068\u3044\u3046\u60f3\u5b9a\u5916\u306e\u9ad8\u6fc3\u5ea6\u3067\u691c\u51fa\u3055\u308c\u3001\u4f55\u304b\u554f\u984c\u304c\u3042\u308b\u3068\u6c17\u3065\u304d\u307e\u3057\u305f\u3002\u88c5\u7f6e\u5074\u306e\u30d6\u30e9\u30f3\u30af\u306b\u306fPFBA\u304c\u691c\u51fa\u3055\u308c\u306a\u304b\u3063\u305f\u305f\u3081\u3001\u30ed\u30c3\u30c8\u6bce\u306b\u5dee\u304c\u3042\u308b\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u7531\u6765\u306a\u306e\u304b\u3001\u305d\u308c\u3068\u3082\u4ed6\u306e\u6d88\u8017\u54c1\u306b\u3088\u308b\u3082\u306e\u306a\u306e\u304b\u3001\u88c5\u7f6e\u4ee5\u5916\u306e\u6c5a\u67d3\u6e90\u306b\u3064\u3044\u3066\u7cbe\u67fb\u3059\u308b\u3053\u3068\u306b\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6c5a\u67d3\u6e90\u8abf\u67fb<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\">\uff11\uff09\u8a66\u85ac\uff1a\u5909\u52d5\u3059\u308bPFAS\u6fc3\u5ea6\u3068\u30ed\u30c3\u30c8\u9593\u5dee<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u3001\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3001\u30ed\u30fc\u30c7\u30a3\u30f3\u30b0\u3001\u6eb6\u51fa\u306e\u5404\u30b9\u30c6\u30c3\u30d7\u306b\u304a\u3044\u3066\u3001\u4e0b\u8a184\u7a2e\u306e\u6eb6\u6db2\u3092\u540410 mL\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002<br>\u25cf \u30ea\u30f3\u9178\u7de9\u885d\u6db2<br>\u25cf \u9162\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u6eb6\u6db2<br>\u25cf \u30e1\u30bf\u30ce\u30fc\u30eb<br>\u25cf 2%\u6c34\u9178\u5316\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0 \u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u6db2<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u8a66\u85ac\u3092\u305d\u308c\u305e\u308c10 mL\u63a1\u53d6\u3057\u30011 mL\u306b\u6fc3\u7e2e\u3057\u3066\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u4ee5\u4e0b\u304cPFAS\u6fc3\u5ea6\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u8a66\u85ac\u540d<\/strong><\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u6e2c\u5b9a\u7d50\u679c\uff08\u00b5g\/mL\uff09<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30ea\u30f3\u9178\u7de9\u885d\u6db2 &nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2 \uff5e 0.5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u9162\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u6eb6\u6db2 &nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.2 \uff5e 0.5<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30e1\u30bf\u30ce\u30fc\u30eb\uff08\u4f7f\u7528\u4e2d\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.08<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30e1\u30bf\u30ce\u30fc\u30eb\uff08\u4ed6\u30d6\u30e9\u30f3\u30c9\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.12 \uff5e 0.92<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">2%\u6c34\u9178\u5316\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0 \u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u6db2<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.61<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f7f\u7528\u4e2d\u306e\u30e1\u30bf\u30ce\u30fc\u30eb\u306f\u6700\u3082\u4f4e\u3044\u6fc3\u5ea6\u3092\u793a\u3057\u3066\u5b89\u5fc3\u3057\u307e\u3057\u305f\u304c\u3001\u540c\u30d6\u30e9\u30f3\u30c9\u3092\u5225\u65e5\u3067\u518d\u30c6\u30b9\u30c8\u3057\u305f\u3068\u3053\u308d\u3001\u6e2c\u5b9a\u3055\u308c\u305f\u6fc3\u5ea6\u306f0.64 \u00b5g\/mL\u3067\u3057\u305f\u3002SPE\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\u3068\u540c\u69d8\u3001\u540c\u4e00\u30ed\u30c3\u30c8\u3067\u3082\u65e5\u306b\u3088\u3063\u3066\u6e2c\u5b9a\u7d50\u679c\u306b\u4e00\u6841\u306e\u5dee\u304c\u51fa\u308b\u5834\u5408\u304c\u3042\u308a\u3001\u8a66\u85ac\u306e\u5b89\u5b9a\u6027\u3084\u7ba1\u7406\u4f53\u5236\u306e\u898b\u76f4\u3057\u304c\u5fc5\u8981\u3067\u3042\u308b\u3053\u3068\u3092\u611f\u3058\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\uff12\uff09\u5bb9\u5668\uff1aPFAS\u5206\u6790\u306b\u304a\u3051\u308b\u300c\u96a0\u308c\u305f\u6c5a\u67d3\u6e90\u300d<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306b\u3001\u62bd\u51fa\u6db2\u306e\u56de\u53ce\u3084\u6e1b\u5bb9\uff08\u30d6\u30ed\u30fc\u30c0\u30a6\u30f3\uff09\u5de5\u7a0b\u3067\u4f7f\u7528\u3059\u308b\u5bb9\u5668\u306e\u6c5a\u67d3\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002\u305d\u308c\u305e\u308c\u306e\u30c1\u30e5\u30fc\u30d6\u306b10 mL\u306e\u30e1\u30bf\u30ce\u30fc\u30eb\uff08\u518d\u30c6\u30b9\u30c8\u3057\u305f\u3082\u306e\uff09\u3092\u5165\u308c\u3066\u30b7\u30a7\u30fc\u30ab\u30fc\u53f0\u30671\u6642\u9593\u64b9\u62cc\u5f8c\u3001PFBA\u6fc3\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u3068\u3044\u3046\u624b\u6cd5\u3092\u63a1\u7528\u3057\u307e\u3057\u305f\u3002\u3044\u305a\u308c\u3082\u3001\u518d\u30c6\u30b9\u30c8\u3057\u305f\u30e1\u30bf\u30ce\u30fc\u30eb\u5358\u4f53\uff080.64 \u00b5g\/mL\uff09\u3068\u8fd1\u3057\u3044\u5024\u3067\u3042\u308a\u3001\u3053\u308c\u3089\u306e\u5bb9\u5668\u81ea\u4f53\u304cPFBA\u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306b\u5927\u304d\u304f\u5bc4\u4e0e\u3057\u3066\u3044\u308b\u3068\u306f\u8003\u3048\u306b\u304f\u3044\u3068\u5224\u65ad\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5bb9\u5668\u540d<\/strong>\u00a0\u00a0<\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u6e2c\u5b9a\u7d50\u679c\uff08\u00b5g\/mL\uff09<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">15 mL \u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u88fd\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.83<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">50 mL \u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u88fd\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.56<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">\uff13\uff09\u305d\u306e\u4ed6\u306e\u5668\u5177<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u8a66\u6599\u3084\u6eb6\u5264\u3068\u63a5\u89e6\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u4ed6\u306e\u5668\u5177\u306b\u3082\u540c\u69d8\u306e\u8a55\u4fa1\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u308c\u305e\u308c\uff08\u624b\u888b\u306f\u6307\u306e\u90e8\u5206\u3092\u5207\u308a\u53d6\u308a\uff09\u3092\u3001\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6\u306b\u5165\u308c\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3068\u5171\u306b\u64b9\u62cc\u3057\u3001PFBA\u6fc3\u5ea6\u3092\u6e2c\u5b9a\u3059\u308b\u3068\u3044\u3046\u624b\u6cd5\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u5668\u5177\u540d<\/strong>\u00a0\u00a0<\/th><th class=\"has-text-align-left\" data-align=\"left\"><strong>\u6e2c\u5b9a\u7d50\u679c\uff08\u00b5g\/mL\uff09<\/strong><\/th><\/tr><\/thead><tbody><tr><td class=\"has-text-align-left\" data-align=\"left\">1 mL \u30d4\u30da\u30c3\u30c8\u30c1\u30c3\u30d7 &nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.29<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">10 mL \u30d4\u30da\u30c3\u30c8\u30c1\u30c3\u30d7 &nbsp;<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.72<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u4f7f\u3044\u6368\u3066SPE\u30e9\u30a4\u30ca\u30fc\uff08PTFE\u88fd\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.23<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5927\u578b\u624b\u888b\uff08\u5b9f\u9a13\u8005\u4f7f\u7528\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">3.04<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u5c0f\u578b\u624b\u888b\uff08\u5b9f\u9a13\u52a9\u624b\u4f7f\u7528\uff09<\/td><td class=\"has-text-align-left\" data-align=\"left\">0.75<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f7f\u3044\u6368\u3066SPE\u30e9\u30a4\u30ca\u30fc\u306fPFTE\u88fd\u306e\u305f\u3081PFAS\u6c5a\u67d3\u306e\u539f\u56e0\u3068\u3057\u3066\u53ef\u80fd\u6027\u306e\u9ad8\u3044\u6750\u8cea\u3067\u3059\u304c\u3001\u4e88\u60f3\u3088\u308a\u4f4e\u6fc3\u5ea6\u306e\u691c\u51fa\u3067\u3057\u305f\u3002\u4e00\u65b9\u3001\u5927\u578b\u624b\u888b\u306f\u975e\u5e38\u306b\u9ad8\u3044PFBA\u6fc3\u5ea6\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u6b8b\u5ff5\u306a\u304c\u3089\u3053\u306e\u624b\u888b\u306f\u4f7f\u3044\u5207\u3063\u3066\u3044\u305f\u305f\u3081\u3001\u3053\u306e\u9ad8\u6fc3\u5ea6\u3092\u518d\u691c\u8a3c\u3059\u308b\u308b\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">PFAS\u6c5a\u67d3\u306f\u300c\u52a0\u7b97\u7684\u6027\u8cea\u300d\u3092\u6301\u3064<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u4e00\u9023\u306e\u8abf\u67fb\u3092\u901a\u3058\u3066\u5f37\u304f\u611f\u3058\u305f\u306e\u306f\u3001\u6975\u3081\u3066\u4f4e\u6fc3\u5ea6\u3067\u306ePFAS\u6c5a\u67d3\u3092\u7ba1\u7406\u3059\u308b\u3053\u3068\u306e\u56f0\u96e3\u3055\u3068\u3001\u591a\u5c64\u7684\u306a\u6c5a\u67d3\u6e90\u306e\u5b58\u5728\u3067\u3059\u3002\u79c1\u81ea\u8eab\u306e\u30d6\u30e9\u30f3\u30af\u306ePFAS\u6fc3\u5ea6\u306f\u73fe\u57281 \u00b5g\/mL\u672a\u6e80\u3067\u5b89\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u305d\u308c\u3092\u7d99\u7d9a\u3059\u308b\u305f\u3081\u306b\u306f\u3001PFAS\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u30d6\u30e9\u30f3\u30af\u306e\u5b9a\u671f\u7684\u306a\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3068\u4f7f\u7528\u3059\u308b\u30e9\u30dc\u7528\u54c1\u306e\u5165\u5ff5\u306a\u78ba\u8a8d\u304c\u4e0d\u53ef\u6b20\u3060\u3068\u3044\u3046\u3053\u3068\u304c\u4eca\u56de\u306e\u691c\u8a3c\u3067\u660e\u3089\u304b\u306b\u306a\u308a\u307e\u3057\u305f\u3002<br>\u307e\u305f\u3001PFAS\u6c5a\u67d3\u306f\u300c\u52a0\u7b97\u7684\u6027\u8cea\u300d\u3092\u6301\u3064\u3068\u3044\u3046\u3053\u3068\u3082\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u3067\u3059\u3002\u3053\u3053\u3067\u691c\u8a3c\u3057\u305f\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u4e2d\u3067\u6ce8\u610f\u3059\u3079\u304d\u9805\u76ee\u3060\u3051\u3067\u3082\u3001SPE\u30c1\u30e5\u30fc\u30d6\u3001SPE\u30b5\u30f3\u30d7\u30eb\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30e9\u30a4\u30f3\u3001\u30b5\u30f3\u30d7\u30eb\u30dc\u30c8\u30eb\u3001SPE\u30e9\u30a4\u30ca\u30fc\u3001\u30d4\u30da\u30c3\u30c8\u30c1\u30c3\u30d7\u3001\u56de\u53ce\u30c1\u30e5\u30fc\u30d6\u3001\u767d\u8863\u3001\u624b\u888b\u3001\u7d14\u6c34\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30ea\u30f3\u9178\u7de9\u885d\u6db2\u3001\u9162\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u3001\u6c34\u9178\u5316\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u3001\u30aa\u30fc\u30c8\u30b5\u30f3\u30d7\u30e9\u30fc\u30d0\u30a4\u30a2\u30eb\u306a\u3069\u3001\u6570\u591a\u304f\u5b58\u5728\u3057\u307e\u3059\u3002\u3053\u308c\u4ee5\u5916\u306b\u3082\u898b\u843d\u3068\u3057\u304c\u3042\u308b\u53ef\u80fd\u6027\u3082\u5426\u5b9a\u3067\u304d\u307e\u305b\u3093\u3002\u7279\u306bWAX\uff08\u5f31\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\uff09SPE\u6cd5\u3067\u306f\u3001\u9ad8\u611f\u5ea6\u306a\u5206\u6790\u64cd\u4f5c\u306b\u591a\u6570\u306e\u30e9\u30dc\u7528\u54c1\u3084\u8a66\u85ac\u304c\u95a2\u4e0e\u3059\u308b\u305f\u3081\u3001\u305f\u3068\u3048\u5404\u30e9\u30dc\u7528\u54c1\u306b\u542b\u307e\u308c\u308b\u6c5a\u67d3\u30ec\u30d9\u30eb\u304cMRL\u3092\u4e0b\u56de\u3063\u3066\u3044\u305f\u3068\u3057\u3066\u3082\u3001\u305d\u308c\u304c\u8907\u6570\u7a4d\u307f\u91cd\u306a\u308c\u3070\u91cd\u5927\u306a\u5f71\u97ff\u3092\u3082\u305f\u3089\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">MRL\u306e\u8a2d\u5b9a\u306f\u300c\u7406\u60f3\u300d\u3067\u306f\u306a\u304f\u300c\u73fe\u5b9f\u300d\u306b\u5373\u3057\u3066<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u5f8c\u306b\u5f37\u8abf\u3057\u3066\u304a\u304d\u305f\u3044\u306e\u306f\u3001\u30e9\u30dc\u3054\u3068\u306b\u8a2d\u5b9a\u3057\u3066\u3044\u308bMRL\u304c\u904b\u7528\u53ef\u80fd\u306a\u73fe\u5b9f\u7684\u6c34\u6e96\u304b\u3069\u3046\u304b\u306e\u518d\u8a55\u4fa1\u306e\u5fc5\u8981\u6027\u3067\u3059\u3002Method 533, Section 9.1.4\u306b\u306f\u3001\u300cMRL\u3092\u4f4e\u304f\u8a2d\u5b9a\u3057\u3059\u304e\u308b\u3068\u3001\u7d99\u7d9a\u7684\u306aQC\u8981\u4ef6\u304c\u7e70\u308a\u8fd4\u3057\u4e0d\u5408\u683c\u306b\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3053\u3068\u3092\u8003\u616e\u3059\u3079\u304d\u3067\u3042\u308b\u300d\u3068\u660e\u8a18\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u6c5a\u67d3\u6fc3\u5ea6\u3092\u5e38\u306bMRL\u306e1\/3\u672a\u6e80\u306b\u4fdd\u3066\u306a\u3044\u306e\u3067\u3042\u308c\u3070\u3001\u305d\u306eMRL\u304c\u73fe\u5834\u3067\u5b9f\u73fe\u4e0d\u53ef\u80fd\u306a\u3001\u4e0d\u9069\u5207\u306a\u76ee\u6a19\u3067\u3042\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u5206\u6790\u306b\u304a\u3044\u3066\u306f\u3001\u898b\u3048\u306a\u3044\u6c5a\u67d3\u6e90\u306e\u5f71\u97ff\u3092\u6700\u5c0f\u5316\u3057\u3001\u73fe\u5b9f\u7684\u304b\u3064\u518d\u73fe\u6027\u306e\u3042\u308b\u5831\u544a\u9650\u754c\uff08MRL\uff09\u3092\u8a2d\u5b9a\u30fb\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u3001\u30e9\u30dc\u5168\u4f53\u3067\u306e\u7d99\u7d9a\u7684\u306a\u7ba1\u7406\u3068\u591a\u89d2\u7684\u306a\u691c\u8a3c\u304c\u4e0d\u53ef\u6b20\u3067\u3042\u308b\u3053\u3068\u3092\u5fc3\u306b\u7559\u3081\u3066\u304a\u3044\u3066\u304f\u3060\u3055\u3044\uff01<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>PFAS\u5206\u6790\u3067\u306f\u591a\u7a2e\u591a\u69d8\u306a\u898b\u3048\u306a\u3044\u6c5a\u67d3\u6e90\u304c\u6700\u5927\u306e\u8ab2\u984c\u3067\u3059\u3002\u73fe\u5834\u3067\u6c42\u3081\u3089\u308c\u308b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u7ba1\u7406\u3084\u5831\u544a\u9650\u754c\u8a2d\u5b9a\u306e\u6700\u65b0\u30dd\u30a4\u30f3\u30c8\u3001\u5b9f\u969b\u306e\u8a66\u85ac\u30fb\u5668\u5177\u304b\u3089\u306e\u6c5a\u67d3\u30ea\u30b9\u30af\u3068\u5bfe\u7b56\u4f8b\u3092\u8a73\u3057\u304f\u89e3\u8aac\u3002\u30e9\u30dc\u73fe\u5834\u3067\u5f79\u7acb\u3064\u73fe\u5b9f\u7684\u306a\u7ba1\u7406\u6cd5\u3068\u904b\u7528\u30dd\u30a4\u30f3\u30c8\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":27,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2760],"industries-application":[2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[447],"class_list":["post-48548","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-pfas","industries-application-environmental-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jason Hoisington","author_link":"https:\/\/discover.restek.com\/ja\/author\/jason-hoisington\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":447,"user_id":27,"is_guest":0,"slug":"jason-hoisington","display_name":"Jason Hoisington","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg"},"author_category":"1","first_name":"Jason","last_name":"Hoisington","user_url":"https:\/\/www.linkedin.com\/in\/jason-hoisington-73067653\/","job_title":"Principal Scientist, Sample Preparation","description":"Jason Hoisington received his bachelor\u2019s degree in general science with a focus on chemistry from the University of Alaska, Fairbanks. He worked for SGS Environmental for seven years in environmental soil and water testing, developing methods for the analysis of volatiles and semivolatile organics to include pesticides and polychlorinated biphenyls (PCBs). In 2012, Jason moved on to lab and application support for Dow Chemical Company, providing advanced analytical troubleshooting and method development. In 2019, Jason joined Restek and has focused on air applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48548","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48548"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48548\/revisions"}],"predecessor-version":[{"id":93982,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48548\/revisions\/93982"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48548"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48548"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48548"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48548"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48548"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48548"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48548"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48548"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48548"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}