{"id":48549,"date":"2019-02-02T13:30:00","date_gmt":"2019-02-02T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-japan\/"},"modified":"2026-04-15T16:16:09","modified_gmt":"2026-04-15T16:16:09","slug":"what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/uncategorized-ja\/gnbl4879-ja\/what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-japan","title":{"rendered":"PFAS\u5206\u6790\u6700\u524d\u7dda\uff1a\u6ce8\u76ee\u3055\u308c\u308b\u4ee3\u66ffPFAS GenX\u3068PFBS"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">PFAS\uff08\u30da\u30eb\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff09\u5206\u6790\u306f\u3001\u74b0\u5883\u5206\u6790\u30e9\u30dc\u306b\u3068\u3063\u3066\u8fd1\u5e74\u3001\u6700\u5927\u306e\u95a2\u5fc3\u4e8b\u3067\u3059\u3002\u7c73\u56fd\u74b0\u5883\u4fdd\u8b77\u5e81\uff08EPA\uff09\u306f\u3001PFAS\u306e\u4ee3\u8868\u7684\u306a\u4e8c\u3064\u306e\u5316\u5408\u7269\u3001PFOA\u304a\u3088\u3073PFOS\u306b\u95a2\u3057\u3001\u98f2\u6599\u6c34\u4e2d\u306e\u5065\u5eb7\u52e7\u544a\u6fc3\u5ea6\u309270ppt\u3068\u8a2d\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002\u3055\u3089\u306b\u30012018\u5e74\u306e\u30ca\u30b7\u30e7\u30ca\u30eb\u30fb\u30ea\u30fc\u30c0\u30fc\u30b7\u30c3\u30d7\u30fb\u30b5\u30df\u30c3\u30c8\u3067\u306f\u3001\u7c73\u56fdEPA\u304c\u4ed6\u306e\u9023\u90a6\u6a5f\u95a2\u3068\u9023\u643a\u3057\u3001\u65b0\u305f\u306b\u4e8c\u3064\u306e\u30d5\u30c3\u7d20\u5316\u5408\u7269\u3001\u30d8\u30ad\u30b5\u30d5\u30eb\u30aa\u30ed\u30d7\u30ed\u30d4\u30ec\u30f3\u30aa\u30ad\u30b7\u30c9\u4e8c\u91cf\u4f53\u9178\uff08HFPO-DA\u3001\u5225\u540dGenX\uff09\u3068\u30d1\u30fc\u30d5\u30eb\u30aa\u30ed\u30d6\u30bf\u30f3\u30b9\u30eb\u30db\u30f3\u9178\uff08PFBS\uff09\u306b\u5bfe\u3059\u308b\u30d2\u30c8\u5065\u5eb7\u6bd2\u6027\u5024\u3092\u7b56\u5b9a\u3059\u308b\u65b9\u91dd\u3092\u767a\u8868\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306f\u3001PFOA\u304a\u3088\u3073PFOS\u306e\u4ee3\u66ff\u54c1\u3068\u3057\u3066\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u306e\u3067\u3001\u305d\u306e\u5b89\u5168\u6027\u306b\u3064\u3044\u3066\u3082\u7d99\u7d9a\u7684\u306a\u8a55\u4fa1\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"887\" height=\"631\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-01-JP-suzu.png\" alt=\"\" class=\"wp-image-17427\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-01-JP-suzu.png 887w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-01-JP-suzu-300x213.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-01-JP-suzu-768x546.png 768w\" sizes=\"auto, (max-width: 887px) 100vw, 887px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">GenX\u3068\u305d\u306e\u524d\u99c6\u4f53\u306f\u52a0\u6c34\u5206\u89e3\u3055\u308c\u3066HFPO-DA\u306b\u5909\u63db\u3055\u308c\u307e\u3059\uff08\u51fa\u5178\uff1aMark Strynar\u304a\u3088\u3073Laurence Libelo \/ \u7c73\u56fdEPA\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u3092PFAS\u5206\u6790\u6210\u5206\u30ea\u30b9\u30c8\u306b\u8ffd\u52a0\u3057\u5206\u6790\u3092\u884c\u3046\u3068\u3001Restek Raptor C18\u30ab\u30e9\u30e0\uff08Cat. #\u00a09304552\uff09\u306b\u3088\u308b\u5206\u6790\u7d50\u679c\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"545\" height=\"513\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-02.jpg\" alt=\"\" class=\"wp-image-17439\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-02.jpg 545w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-what-are-genx-and-pfbs-why-are-they-important-in-pfas-analysis-02-300x282.jpg 300w\" sizes=\"auto, (max-width: 545px) 100vw, 545px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u65e2\u306bGenX\u3068PFBS\u3092\u5206\u6790\u6210\u5206\u3068\u3057\u3066\u3044\u308b\u5834\u5408\u3001Restek Raptor C18\u30ab\u30e9\u30e0\uff08Cat. #\u00a09304552\uff09\u3067\u3088\u308a\u9ad8\u901f\u306a\u5206\u6790\uff08\u30e9\u30f3\u30bf\u30a4\u30e0\u7d044\u5206\uff09\u304c\u5b9f\u73fe\u3057\u307e\u3059\u3002\u4e00\u822c\u7684\u306b\u6eb6\u51fa\u306e\u65e9\u3044PFBS\u306e\u4fdd\u6301\u6642\u9593\u306f1.6\u5206\u3067\u3001\u691c\u51fa\u9650\u754c\u4ee5\u4e0b\u306e\u8aa4\u691c\u51fa\u3082\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3055\u3089\u306b\u591a\u69d8\u306aPFAS\u6210\u5206\u306e\u5206\u6790\u3084\u3001\u3088\u308a\u826f\u597d\u306a\u5206\u96e2\u304c\u5fc5\u8981\u3067\u3059\u304b\uff1f\u7c92\u5b50\u5f842\u00b5m\u4ee5\u4e0b\u306e\u9ad8\u6027\u80fd\u30ab\u30e9\u30e0\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u6c42\u3081\u3066\u3044\u307e\u3059\u304b\uff1fRestek\u306a\u3089\u3001\u30cb\u30fc\u30ba\u306b\u5fdc\u3058\u3066\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3092\u306e\u3054\u63d0\u6848\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306fPFAS\u306b\u95a2\u3059\u308b\u7814\u7a76\u3092\u52a0\u901f\u3055\u305b\u3066\u3044\u304d\u307e\u3059\u3002\u3069\u3046\u305e\u3054\u671f\u5f85\u304f\u3060\u3055\u3044\uff01<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304552\">                                \u30ab\u30bf\u30ed\u30b0No. 9304552                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor C18, 5 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9304552\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">&#8220;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>PFAS\u306e\u6700\u65b0\u5206\u6790\u52d5\u5411\u3068Restek Raptor C18\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u9ad8\u901f\u30fb\u9ad8\u7cbe\u5ea6\u5206\u6790\u3092\u89e3\u8aac\u3002GenX\u3084PFBS\u306a\u3069\u306e\u4ee3\u66ff\u30d5\u30c3\u7d20\u5316\u5408\u7269\u306e\u6e2c\u5b9a\u306b\u5bfe\u5fdc\u3057\u3001\u591a\u69d8\u306a\u6210\u5206\u5206\u6790\u3084\u826f\u597d\u306a\u5206\u96e2\u3092\u6c42\u3081\u308b\u74b0\u5883\u30e9\u30dc\u306b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3092\u63d0\u6848\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":65,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[],"tags":[2760],"industries-application":[2288,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2365,2347],"ppma_author":[601],"class_list":["post-48549","post","type-post","status-publish","format-standard","hentry","tag-pfas","industries-application-pfas-testing-ja","industries-application-environmental-ja","resource-technique-ms-ms-ja","resource-technique-solid-phase-microextraction-spme-ja"],"acf":[],"taxonomy_info":{"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2347,"label":"\u56fa\u76f8\u30de\u30a4\u30af\u30ed\u62bd\u51fa (SPME)"}]},"featured_image_src_large":false,"author_info":{"display_name":"SaVanna Cano","author_link":"https:\/\/discover.restek.com\/ja\/author\/savanna-cano\/"},"comment_info":0,"category_info":[],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":49,"filter":"raw"}],"authors":[{"term_id":601,"user_id":0,"is_guest":1,"slug":"mike-chang","display_name":"Mike Chang","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-square-chang-mike.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-square-chang-mike.jpg"},"author_category":"1","first_name":"Mike","last_name":"Chang","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48549","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/65"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48549"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48549\/revisions"}],"predecessor-version":[{"id":79011,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48549\/revisions\/79011"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48549"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48549"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48549"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48549"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48549"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48549"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48549"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48549"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48549"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}