{"id":48553,"date":"2012-05-10T14:30:00","date_gmt":"2012-05-10T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-capillary-gc-column-killers-part-1\/"},"modified":"2026-01-28T22:14:55","modified_gmt":"2026-01-28T22:14:55","slug":"japanese-capillary-gc-column-killers-part-1","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4606-ja\/japanese-capillary-gc-column-killers-part-1","title":{"rendered":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u30ad\u30e9\u30fc\uff08\u30ab\u30e9\u30e0\u3092\u52a3\u5316\u3055\u305b\u308b\u539f\u56e0\uff09 \u2013 Part 1\uff08\u65e5\u672c\u8a9e\uff09"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u307b\u3068\u3093\u3069\u5206\u6790\u8005\u306f\u3001\u9ad8\u6e29\u306e\u72b6\u614b\u3067\u3001\u9178\u7d20\u304c\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u306b\u5165\u308b\u3068\u3001\u56fa\u5b9a\u76f8\u3092\u640d\u3046\u306e\u3067\u3001\u4f7f\u7528\u6e29\u5ea6\u7bc4\u56f2\u3088\u308a\u9ad8\u3044\u6e29\u5ea6\u3067\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u306f\u3044\u3051\u306a\u3044\u4e8b\u3092\u77e5\u3063\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u306epH\u3084\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u3001\u81ea\u7136\u754c\u306e\u786b\u9ec4\u6210\u5206\u3001\u6c34\u5206\u306e\u6ce8\u5165\u306a\u3069\u3001\u3042\u307e\u308a\u77e5\u3089\u308c\u3066\u3044\u306a\u3044\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u52a3\u5316\u539f\u56e0\u3082\u3042\u308a\u307e\u3059\u3002\u305d\u3053\u3067\u3001\u3053\u308c\u304b\u30894\u56de\u306b\u5206\u3051\u3066\u3001\u30ab\u30e9\u30e0\u3092\u52a3\u5316\u3055\u305b\u308b\u539f\u56e0\u306b\u3064\u3044\u3066\u30b7\u30ea\u30fc\u30ba\u3067\u8ff0\u3079\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9a\u91cf\u7684\u306a\u30c7\u30fc\u30bf\u3068\u3057\u3066\u304a\u793a\u3057\u306f\u3067\u304d\u307e\u305b\u3093\u304c\u3001\u3053\u308c\u3089\u306e\u60c5\u5831\u306f\u3001\u7d4c\u9a13\u8c4a\u304b\u306a\u5206\u6790\u8005\u304b\u3089\u63d0\u4f9b\u3055\u308c\u305f\u7269\u3067\u3042\u3063\u305f\u308a\u3001\u500b\u4eba\u7684\u306b\u5f97\u305f\u7d4c\u9a13\u3068\u30d5\u30a3\u30fc\u30c9\u30d0\u30c3\u30af\u306b\u57fa\u3065\u3044\u305f\u3082\u306e\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u30c8\u30d4\u30c3\u30af\u30b9\u306f\u6c7a\u3057\u3066\u3001\u5305\u62ec\u7684\u306a\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u30ab\u30e9\u30e0\u3078\u6ce8\u5165\u3059\u308b\u969b\u306b\u3001\u305d\u306e\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u306a\u306b\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u306e\u304b\u3092\u4eca\u4e00\u5ea6\u8003\u3048\u3066\u307f\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001\u3053\u308c\u3089\u306e\u5185\u5bb9\u306f\u30af\u30ed\u30b9\u30ea\u30f3\u30af\uff08\u5316\u5b66\u7d50\u5408\uff09\u3055\u308c\u305f\u56fa\u5b9a\u76f8\u306b\u7279\u6709\u3067\u3042\u308b\u3053\u3068\u306b\u3054\u6ce8\u610f\u304f\u3060\u3055\u3044\u3002\u30af\u30ed\u30b9\u30ea\u30f3\u30af\u3055\u308c\u3066\u3044\u306a\u3044\u30ab\u30e9\u30e0\u3084\u90e8\u5206\u7684\u306b\u3057\u304b\u30af\u30ed\u30b9\u30ea\u30f3\u30af\u3055\u308c\u3066\u3044\u306a\u3044\u30ab\u30e9\u30e0\u306e\u5834\u5408\u3001\u4e00\u822c\u7684\u306b\u306f\u30c0\u30e1\u30fc\u30b8\u3092\u53d7\u3051\u3084\u3059\u304f\u3001\u30ab\u30e9\u30e0\u5bff\u547d\u304c\u77ed\u304f\u306a\u3063\u305f\u308a\u3001\u30d6\u30ea\u30fc\u30c9\u304c\u3088\u308a\u9ad8\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>\u6975\u7aef\u306a\u30b5\u30f3\u30d7\u30eb\u306epH\u5024<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3055\u308c\u308b\u30b5\u30f3\u30d7\u30eb\uff0f\u62bd\u51fa\u7269\u306epH\u304c\u30015~9\u306e\u7bc4\u56f2\u5916\u306e\u5834\u5408\u3001\u56fa\u5b9a\u76f8\u3084\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u306e\u4e0d\u6d3b\u6027\u51e6\u7406\u5c64\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30ebpH\u304c\u3053\u306e\u7bc4\u56f2\u5916\u306e\u5834\u5408\u3001\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u304c\u5927\u304d\u304f\u306a\u3063\u305f\u308a\u3001\u5206\u96e2\u304c\u60aa\u304f\u306a\u3063\u305f\u308a\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u30b5\u30f3\u30d7\u30eb\uff0f\u62bd\u51fa\u7269\u306epH\u304c\u3053\u306e\u7bc4\u56f2\u304b\u3089\u5927\u304d\u304f\u5916\u308c\u3066\u3044\u308b\u307b\u3069\u3001\u30ab\u30e9\u30e0\u306f\u30c0\u30e1\u30fc\u30b8\u3092\u53d7\u3051\u3084\u3059\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3082\u3057\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\uff0f\u62bd\u51fa\u7269\u304c\u3001\u5b89\u5168\u306apH\u7bc4\u56f2\u3092\u8d8a\u3048\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308c\u3070\u3001pH\u8a66\u9a13\u7d19\u3067\u4e8b\u524d\u306bpH\u3092\u78ba\u8a8d\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"200\" height=\"200\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-1-01.jpg\" alt=\"\" class=\"wp-image-13150\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-1-01.jpg 200w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-1-01-150x150.jpg 150w\" sizes=\"auto, (max-width: 200px) 100vw, 200px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Photo courtesy of\u00a0VWR Lab Shop\u00a0.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3042\u306a\u305f\u306e\u30b5\u30f3\u30d7\u30eb\uff0f\u62bd\u51fa\u7269\u306epH\u304c5-9\u306e\u7bc4\u56f2\u5916\u306b\u3042\u308b\u3088\u3046\u306a\u3089\u3001\u6ce8\u5165\u3059\u308b\u524d\u306b\u307e\u305apH\u304c5-9\u306e\u7bc4\u56f2\u306b\u5165\u308b\u3088\u3046\u306b\u3001\u8abf\u6574\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u306f\u3044\u304f\u3064\u304b\u306e\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u6700\u826f\u306e\u65b9\u6cd5\u306f\u3001pH\u304c5\u304b\u30899\u3068\u306a\u308b\u3088\u3046\u306b\u3001\u30b5\u30f3\u30d7\u30eb\uff0f\u62bd\u51fa\u7269\u3092\u5e0c\u91c8\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u7de9\u885d\u5869\u3092\u4f7f\u7528\u3059\u308b\u3068\u3001\u5869\u304c\u30ab\u30e9\u30e0\u5185\u306b\u6790\u51fa\u3057\u3066\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b \u300c\u7de9\u885d\u300d\u306f\u3001\u30b5\u30f3\u30d7\u30eb\uff0f\u62bd\u51fa\u7269\u4e2d\u306e\u76ee\u7684\u6210\u5206\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5869\u57fa\u6027\u5316\u5408\u7269\u306e\u5206\u6790\uff1a<br>Rtx-Volatile Amine\u3001Rtx-5 Amine\u3001Rtx-35 Amine\u53ca\u3073Stabilwax-DB\u3092\u3054\u4f7f\u7528\u306e\u5834\u5408\u306b\u306f\u3001\u63a8\u5968\u30b5\u30f3\u30d7\u30ebpH\u7bc4\u56f2\u306f7~9\u3067\u3059\u3002<\/li>\n\n\n\n<li>\u9178\u6027\u5316\u5408\u7269\u306e\u5206\u6790<br>Stabilewax-DA\u3092\u3054\u4f7f\u7528\u306e\u5834\u5408\u306b\u306f\u3001\u63a8\u5968\u30b5\u30f3\u30d7\u30ebpH\u7bc4\u56f2\u306f5~7\u3067\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u3054\u53c2\u8003\u306b\u306a\u308c\u3070\u5e78\u3044\u3067\u3059\u3002\u3069\u3046\u305e\u3001\u3053\u306e\u30b7\u30ea\u30fc\u30ba\u306e\u30d1\u30fc\u30c82-4\u3082\u53c2\u8003\u306b\u306a\u3055\u3063\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Most analysts already know that at elevated temperatures, oxygen damages the stationary phase inside a capillary gas chromatography column, and so does operating a column above the recommended maximum temperature. However, there are also several lesser known capillary column killers&#8230;<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[582],"class_list":["post-48553","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/ja\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48553","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48553"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48553\/revisions"}],"predecessor-version":[{"id":85775,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48553\/revisions\/85775"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48553"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48553"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48553"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48553"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48553"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48553"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48553"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48553"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48553"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}