{"id":48554,"date":"2012-05-21T14:30:00","date_gmt":"2012-05-21T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-capillary-gc-column-killers-part-2\/"},"modified":"2026-01-28T22:15:18","modified_gmt":"2026-01-28T22:15:18","slug":"japanese-capillary-gc-column-killers-part-2","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4607-ja\/japanese-capillary-gc-column-killers-part-2","title":{"rendered":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u30ad\u30e9\u30fc\uff08\u30ab\u30e9\u30e0\u3092\u52a3\u5316\u3055\u305b\u308b\u539f\u56e0\uff09 \u2013 Part 2\uff08\u65e5\u672c\u8a9e\uff09"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u9023\u8f092\u56de\u76ee\u306e\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u30ad\u30e9\u30fc\u306f\u3001\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u306b\u3064\u3044\u3066\u3067\u3059\u3002 \u9023\u8f09 1\u56de\u76ee\u3092\u307e\u3060\u8aad\u3093\u3067\u306a\u3044\u65b9\u306f\u3001\u9069\u5207\u306a\u30b5\u30f3\u30d7\u30eb\u306epH\u7bc4\u56f2\u306b\u3064\u3044\u3066\u3067\u3059\u306e\u3067\u3001\u305c\u3072\u304a\u8aad\u307f\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3044\u3066\u3001\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u306f\u3001\u7279\u5b9a\u306e\u5b98\u80fd\u57fa\u3092\u5225\u306e\u5b98\u80fd\u57fa\u306b\u7f6e\u304d\u63db\u3048\u308b\u3053\u3068\u3067\u4e0d\u63ee\u767a\u6027\u306e\u5316\u5408\u7269\u3092\u63ee\u767a\u6027\u306e\u5316\u5408\u7269\u306b\u5909\u63db\u3059\u308b\u305f\u3081\u306b\u3088\u304f\u7528\u3044\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u4ed6\u3001\u5316\u5408\u7269\u306e\u71b1\u5b89\u5b9a\u6027\u3092\u9ad8\u3081\u305f\u308a\u3001\u691c\u51fa\u611f\u5ea6\u3092\u4e0a\u3052\u308b\u305f\u3081\u306b\u3082\u7528\u3044\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"80\" height=\"80\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-2-01.jpg\" alt=\"\" class=\"wp-image-13156\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3060\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u904e\u5270\u306a\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u306f\u30ab\u30e9\u30e0\u56fa\u5b9a\u76f8\u306b\u4fee\u5fa9\u4e0d\u53ef\u80fd\u306a\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u6050\u308c\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u591a\u304f\u306e\u5834\u5408\u306f\u4f59\u5206\u306a\u8a66\u85ac\u3092\u9664\u53bb\u3059\u308b\u305f\u3081\u306b\u8a98\u5c0e\u4f53\u5316\u30b5\u30f3\u30d7\u30eb\u3092\u4e7e\u56fa\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u30b5\u30f3\u30d7\u30eb\u6b8b\u7559\u7269\u306b\u304d\u308c\u3044\u306a\u6eb6\u5a92\u3092\u52a0\u3048\u3066\u5e0c\u91c8\u3057\u3001\u5206\u6790\u3092\u304a\u3053\u306a\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6700\u3082\u5927\u304d\u3044\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u306e\u3044\u304f\u3064\u304b\u306b\u3001\u30c8\u30ea\u30d5\u30eb\u30aa\u30ed\u7121\u6c34\u9162\u9178\uff08TFAA\uff09\u3084\u30da\u30f3\u30bf\u30d5\u30eb\u30aa\u30ed\u7121\u6c34\u30d7\u30ed\u30d4\u30aa\u30f3\u9178\uff08PFPA\uff09\u3001\u304a\u3088\u3073\u30d8\u30d7\u30bf\u30d5\u30eb\u30aa\u30ed\u7121\u6c34\u916a\u9178\uff08HFBA\uff09\u304c\u3042\u308a\u307e\u3059\u3002 \u3053\u308c\u3089\u306e\u8a66\u85ac\u306f\u9178\u6027\u306e\u526f\u7523\u7269\u3092\u751f\u6210\u3057\u3001\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b7\u30ea\u30eb\u5316\u8a66\u85ac\u3067\u3042\u308b\u30c8\u30ea\u30d5\u30eb\u30aa\u30ed\u9162\u9178\uff08TFA\uff09\u3068\u30b8\u30e1\u30c1\u30eb\u30b8\u30af\u30ed\u30ed\u30b7\u30e9\u30f3\uff08DMDCS\uff09\u306f\u3001\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08Carbowax\uff09\u56fa\u5b9a\u76f8\u306b\u7279\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u307e\u3059\u304c\u3001\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\u56fa\u5b9a\u76f8\u306b\u5bfe\u3057\u3066\u306f\u3042\u307e\u308a\u5927\u304d\u306a\u30c0\u30e1\u30fc\u30b8\u306f\u4e0e\u3048\u307e\u305b\u3093\u3002 \u591a\u304f\u306e\u30b7\u30ea\u30eb\u5316\u8a66\u85ac\u3068\u540c\u69d8\u306b\u3001TMS\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u306f\u3001\u6d3b\u6027\u6c34\u7d20\u539f\u5b50\u3068\u53cd\u5fdc\u3057\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u3053\u308c\u3089\u306e\u8a66\u85ac\u3092\u4f7f\u7528\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790\u3067\u306f\u3001\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb(Carbowax)\u56fa\u5b9a\u76f8\u306e\u30ab\u30e9\u30e0\u306f\u4f7f\u7528\u3057\u306a\u3044\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307b\u3068\u3093\u3069\u306e\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u306f\u30ab\u30e9\u30e0\u3092\u52a3\u5316\u3055\u305b\u308b\u3068\u8003\u3048\u308b\u3079\u304d\u3067\u3059\u304c\u3001\u30a2\u30b7\u30eb\u5316\u8a66\u85ac\u3067\u3042\u308bN-\u30e1\u30c1\u30eb\u30d3\u30b9\u30c8\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30bb\u30bf\u30df\u30c9\uff08MBTFA\uff09\u3068\u30d1\u30fc\u30d5\u30eb\u30aa\u30ed\u30a2\u30b7\u30ea\u30df\u30c0\u30be\u30fc\u30eb\uff08trifluoroacetylimidazole\uff0dTFAI\u3001pentafluoropropanylimidazole\uff0dPFPI\u3001heptafluorobutyrylimidazole\uff0dHFBI\uff09\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u56fa\u5b9a\u76f8\u306b\u3042\u307e\u308a\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u306a\u3044\u3068\u3044\u3046\u4f8b\u5916\u304c\u3042\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u30ab\u30e9\u30e0\u306b\u30c0\u30e1\u2015\u30b8\u3092\u4e0e\u3048\u306a\u304f\u3066\u3082\u3001\u6ce8\u5165\u53e3\u306e\u6c5a\u67d3\u3084\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u306e\u539f\u56e0\u3068\u306a\u308b\u53ef\u80fd\u6027\u306f\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u306e\u4f7f\u7528\u306b\u304a\u3044\u3066\u3001\u3069\u306e\u8a66\u85ac\u304c\u5b89\u5168\u3067\u3069\u306e\u8a66\u85ac\u304c\u30ab\u30e9\u30e0\u306b\u52a3\u5316\u3092\u3082\u305f\u3089\u3059\u306e\u304b\u306b\u95a2\u3059\u308b\u5b8c\u5168\u306a\u30ea\u30b9\u30c8\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u3067\u51e6\u7406\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u3059\u308b\u5834\u5408\u306b\u306f\u3001\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u30ab\u30e9\u30e0\u306b\u5f71\u97ff\u3092\u4e0e\u3048\u3066\u3044\u308b\u5834\u5408\u306b\u306f\u3001\u5225\u306e\u8a98\u5c0e\u4f53\u5316\u8a66\u85ac\u3092\u8a66\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>For my second installment of Capillary GC Column Killers, I am going to discuss derivatization reagents. If you haven&rsquo;t already read my first installment which covered the topic of a &ldquo;safe&rdquo; pH range, I encourage you to do so. Capillary&#8230;<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[2823],"class_list":["post-48554","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/ja\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48554","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48554"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48554\/revisions"}],"predecessor-version":[{"id":85776,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48554\/revisions\/85776"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48554"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48554"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48554"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48554"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48554"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48554"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48554"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48554"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48554"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}