{"id":48555,"date":"2012-05-24T14:30:00","date_gmt":"2012-05-24T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-capillary-gc-column-killers-part-3\/"},"modified":"2026-01-23T19:29:29","modified_gmt":"2026-01-23T19:29:29","slug":"japanese-capillary-gc-column-killers-part-3","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4608-ja\/japanese-capillary-gc-column-killers-part-3","title":{"rendered":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u30ad\u30e9\u30fc\uff08\u30ab\u30e9\u30e0\u3092\u52a3\u5316\u3055\u305b\u308b\u539f\u56e0\uff09\u3000Part 3\uff08\u65e5\u672c\u8a9e\uff09"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">\u5358\u4f53\u786b\u9ec4<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u304f\u306e\u8a66\u6599\u62bd\u51fa\u7269\u3001\u7279\u306b\u77f3\u6cb9\u88fd\u54c1\u7531\u6765\u306e\u62bd\u51fa\u7269\u306b\u306f\u5358\u4f53\u786b\u9ec4\u304c\u542b\u307e\u308c\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u77f3\u6cb9\u7cbe\u88fd\u6642\u306e\u8131\u786b\u306b\u3088\u308b\u526f\u7523\u7269\u306f\u3001\u786b\u9ec4\u306e\u4f9b\u7d66\u6e90\u306e\u3072\u3068\u3064\u3067\u3082\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u4ed6\u306b\u9ad8\u6fc3\u5ea6\u306e\u5358\u4f53\u786b\u9ec4\u3092\u542b\u3080\u8a66\u6599\u3068\u3057\u3066\u306f\u3001\u6d77\u6d0b\u5806\u7a4d\u7269\u3084\u7523\u696d\u5ec3\u68c4\u7269\u306a\u3069\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"250\" height=\"188\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-01.jpg\" alt=\"\" class=\"wp-image-13162\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Photo from Wikipedia<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5358\u4f53\u786b\u9ec4\u306f\u53b3\u5bc6\u306a\u610f\u5473\u3067\u306f\u30ab\u30e9\u30e0\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u56fa\u5b9a\u76f8\u306e\u6c5a\u67d3\u539f\u56e0\u3067\u3042\u308a\u3001\u305d\u306e\u9664\u53bb\u306f\u975e\u5e38\u306b\u56f0\u96e3\u3067\u3059\u3002\u786b\u9ec4\u306f\u975e\u5e38\u306b\u53cd\u5fdc\u6027\u304c\u9ad8\u3044\u305f\u3081\u3001\u4e00\u5ea6\u786b\u9ec4\u306b\u3088\u3063\u3066\u6c5a\u67d3\u3055\u308c\u305f\u56fa\u5b9a\u76f8\u306f\u6d3b\u6027\u306e\u3042\u308b\u5316\u5408\u7269\u306e\u5438\u7740\u3082\u3057\u304f\u306f\u5206\u89e3\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3068\u308a\u308f\u3051\u8fb2\u85ac\u5206\u6790\u306b\u5f53\u3066\u306f\u307e\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u524d\u304b\u3089\u3001EPA\u306f\u5358\u4f53\u786b\u9ec4\u3092\u542b\u6709\u3059\u308b\u8a66\u6599\u304c\u8a66\u6599\u5206\u6790\u6642\u306b\u554f\u984c\u3092\u5f15\u304d\u8d77\u3053\u3059\u3053\u3068\u3092\u6307\u6458\u3057\u3066\u3044\u307e\u3057\u305f\u3002EPA\u30e1\u30bd\u30c3\u30c98081A\u30018082A\u304a\u3088\u30738141A\u3067\u306f\u3001\u5358\u4f53\u786b\u9ec4\u542b\u6709\u306e\u53ef\u80fd\u6027\u304c\u3042\u308b\u8a66\u6599\u306b\u3064\u3044\u3066\u306f\u3001\u6d3b\u6027\u5316\u3055\u308c\u305f\u9285\u307e\u305f\u306f\u4e9c\u786b\u9178\u30c6\u30c8\u30e9\u30d6\u30c1\u30eb\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u306b\u3088\u308b\u786b\u9ec4\u306e\u9664\u53bb\u304c\u63a8\u5968\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u786b\u9ec4\u9664\u53bb\u306e\u8a73\u7d30\u306b\u3064\u3044\u3066\u306f\u3001<a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2015-12\/documents\/3660b.pdf\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.epa.gov\/sites\/default\/files\/2015-12\/documents\/3660b.pdf\" rel=\"noreferrer noopener\">US EPA Method 3660B<\/a>\u00a0\u3092\u3054\u89a7\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3060\u3057\u3001\u786b\u9ec4\u306e\u30af\u30ea\u30fc\u30f3\u30ca\u30c3\u30d7\u3092\u304a\u3053\u306a\u3063\u305f\u5834\u5408\u3001\u3044\u304f\u3064\u304b\u306e\u76ee\u7684\u5316\u5408\u7269\u3082\u9664\u53bb\u3055\u308c\u3066\u3057\u307e\u3046\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u5fc5\u305a\u4e88\u5099\u8a66\u9a13\u3092\u304a\u3053\u306a\u3063\u3066\u304f\u3060\u3055\u3044\u3002\u00a0<a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2015-12\/documents\/3640a.pdf\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.epa.gov\/sites\/default\/files\/2015-12\/documents\/3640a.pdf\" rel=\"noreferrer noopener\">EPA Method 3640A<\/a>\u00a0(GPC Cleanup) \u3082\u30b5\u30f3\u30d7\u30eb\u304b\u3089\u306e\u786b\u9ec4\u9664\u53bb\u306b\u4f7f\u7528\u3067\u304d\u3001\u591a\u304f\u306e\u5834\u5408\u3001\u671b\u307e\u3057\u304f\u306a\u3044\u5316\u5b66\u53cd\u5fdc\u3092\u8d77\u3053\u3055\u306a\u3044\u3068\u306e\u610f\u898b\u3082\u805e\u304d\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u76ee\u7684\u306e\u5316\u5408\u7269\u304c\u786b\u9ec4\u3068\u540c\u6642\u306bGPC\u30ab\u30e9\u30e0\u304b\u3089\u6eb6\u51fa\u3059\u308b\u5834\u5408\u3001\u4ed6\u306e\u30af\u30ea\u30fc\u30f3\u30ca\u30c3\u30d7\u6cd5\u3092\u8003\u3048\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0b\u56f3\u306f\u3001\u786b\u9ec4\u306e\u30d4\u30fc\u30af\u3092\u793a\u3057\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u4f8b(Jack Cochran\u6c0f\u3088\u308a\u3054\u63d0\u4f9b)\u3067\u3059\u3002\u8d64\u3044\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u30af\u30ea\u30fc\u30f3\u30ca\u30c3\u30d7\u524d\u3001\u9752\u8272\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u30af\u30ea\u30fc\u30f3\u30ca\u30c3\u30d7\u5f8c\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u6e2c\u5b9a\u5bfe\u8c61\u306f\u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac\u3067\u3001\u691c\u51fa\u5668\u306fECD\u3067\u3059\u3002\u3053\u306e\u5927\u304d\u306a\u786b\u9ec4\u30d4\u30fc\u30af\u306f\u3001\u76ee\u7684\u306e\u5316\u5408\u7269\u306e\u5b9a\u91cf\u306e\u59a8\u3052\u3068\u306a\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u524d\u8ff0\u306e\u3088\u3046\u306b\u3001\u30ab\u30e9\u30e0\u3092\u975e\u5e38\u306b\u53cd\u5fdc\u6027\u306e\u9ad8\u3044\u3082\u306e\u3078\u5909\u3048\u3066\u3057\u307e\u3046\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"916\" height=\"560\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-02.bmp\" alt=\"\" class=\"wp-image-13168\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-02.bmp 916w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-02-300x183.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-capillary-gc-column-killers-part-3-02-768x470.jpg 768w\" sizes=\"auto, (max-width: 916px) 100vw, 916px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">\u5358\u4f53\u786b\u9ec4\u306e\u691c\u51fa\u3084\u5b9a\u91cf\u304c\u76ee\u7684\u306e\u5834\u5408\u3082\u3082\u3061\u308d\u3093\u3042\u308a\u307e\u3059\u3002ASTM\u30e1\u30bd\u30c3\u30c9\u306b\u306f\u3001\u77f3\u6cb9\u88fd\u54c1\u4e2d\u306e\u786b\u9ec4\u5143\u7d20\u306e\u5b9a\u91cf\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u6700\u8fd1\u3067\u306f\u3001\u77f3\u818f\u30dc\u30fc\u30c9\u4e2d\u306e\u786b\u9ec4\u5143\u7d20\u3084\u786b\u9ec4\u5316\u5408\u7269\u306e\u5206\u6790\u7528\u30e1\u30bd\u30c3\u30c9\u3082\u958b\u767a\u3055\u308c\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u4e0b\u8a18\u30ea\u30f3\u30af\u306f\u3001EPA\u306e\u77f3\u818f\u30dc\u30fc\u30c9\u4e2d\u306e\u786b\u9ec4\u5206\u6790\u306b\u95a2\u3059\u308b\u30dd\u30b9\u30bf\u30fc\u306e\u30ea\u30f3\u30af\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u77f3\u6cb9\u88fd\u54c1\u3084\u6d77\u6d0b\u5806\u7a4d\u7269\u3001\u7523\u696d\u5ec3\u68c4\u7269\u306a\u3069\u306e\u30b5\u30f3\u30d7\u30eb\u3092\u5206\u6790\u5f8c\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306b\u554f\u984c(\u30c6\u30fc\u30ea\u30f3\u30b0\u3084\u6d3b\u6027\u306e\u3042\u308b\u5316\u5408\u7269\u306e\u611f\u5ea6\u4f4e\u4e0b\u3001\u8aac\u660e\u306e\u3064\u304b\u306a\u3044\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u76db\u4e0a\u308a\u306a\u3069)\u304c\u751f\u3058\u305f\u5834\u5408\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u4e2d\u306b\u5b58\u5728\u3059\u308b\u5358\u4f53\u786b\u9ec4\u306b\u3088\u308b\u5f71\u97ff\u306e\u53ef\u80fd\u6027\u3082\u3042\u308a\u307e\u3059\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u6b63\u5e38\u306b\u4fdd\u3064\u305f\u3081\u306b\u3001\u3053\u306e\u3088\u3046\u306a\u5316\u5408\u7269\u306e\u9664\u53bb\u3092\u4e88\u3081\u3057\u3066\u304a\u304f\u3068\u3001\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u306b\u304b\u304b\u308b\u6642\u9593\u3092\u6e1b\u3089\u3059\u3053\u3068\u304c\u3067\u304d\u308b\u53ef\u80fd\u6027\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Elemental Sulfur Part 3 of my installment of Capillary GC Column Killers includes a compound known to just about everyone, sulfur. Either analysts have been aware for years that this compound has been in their samples\/extracts, or they are surprised&#8230;<\/p>\n","protected":false},"author":5,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[2270,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[2823],"class_list":["post-48555","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","industries-application-energy-ja","industries-application-environmental-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"industries-application":[{"value":2270,"label":"\u30a8\u30cd\u30eb\u30ae\u30fc"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Brenda Seprish","author_link":"https:\/\/discover.restek.com\/ja\/author\/brenda-coganrestek-com\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48555","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/5"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48555"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48555\/revisions"}],"predecessor-version":[{"id":84336,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48555\/revisions\/84336"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48555"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48555"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48555"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48555"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48555"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48555"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48555"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48555"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48555"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}