{"id":48556,"date":"2012-05-31T14:30:00","date_gmt":"2012-05-31T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-capillary-gc-column-killers-part-4\/"},"modified":"2025-11-13T21:02:23","modified_gmt":"2025-11-13T21:02:23","slug":"japanese-capillary-gc-column-killers-part-4","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4609-ja\/japanese-capillary-gc-column-killers-part-4","title":{"rendered":"\u30ad\u30e3\u30d4\u30e9\u30ea\u30fcGC\u30ab\u30e9\u30e0\u30ad\u30e9\u30fc\uff08\u30ab\u30e9\u30e0\u3092\u52a3\u5316\u3055\u305b\u308b\u539f\u56e0\uff09\u3000Part 4\uff08\u65e5\u672c\u8a9e\uff09"},"content":{"rendered":"\n<h4 class=\"wp-block-heading\">\u6c34\u5206\u306e\u6ce8\u5165<\/h4>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ad\u30e3\u30d4\u30e9\u30eaGC\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u3092\u52a3\u5316\u3055\u305b\u308b\u539f\u56e0\u306e\u6700\u5f8c\u306e\u7ae0\u3067\u306f\u3001\u6c34\u5206\u306e\u6ce8\u5165\u306b\u95a2\u3057\u3066\u66f8\u3044\u3066\u307f\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002GC\u306b\u6c34\u5206\u3092\u6ce8\u5165\u3059\u308b\u3053\u3068\u306b\u95a2\u3057\u3066\u306f\u591a\u304f\u306e\u8aa4\u89e3\u3082\u3042\u308b\u3068\u601d\u3044\u307e\u3059\u3057\u3001\u78ba\u304b\u306b\u305d\u306e\u7406\u7531\u3082\u9593\u9055\u3063\u3066\u306f\u3044\u307e\u305b\u3093\u3002\u96fb\u5b50\u6a5f\u5668\u306b\u6c34\u5206\u306f\u7981\u7269\u3067\u3042\u308b\u3068\u3044\u3046\u4e00\u822c\u7684\u306a\u77e5\u8b58\u306e\u4ed6\u306b\u3001\u5206\u6790\u8005\u306e\u591a\u304f\u306f\u6c34\u5206\u3092GC\u306b\u6ce8\u5165\u3057\u305f\u5834\u5408\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u4f55\u304b\u3057\u3089\u306e\u554f\u984c\u3092\u7d4c\u9a13\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30dd\u30ea\u30de\u30fc\u304c\u67b6\u6a4b\u7d50\u5408\u3057\u3066\u3044\u308b\u307b\u3068\u3093\u3069\u306e\u7d50\u5408\u578b\u30ab\u30e9\u30e0\u56fa\u5b9a\u76f8\u3067\u306f\u3001\u6c34\u5206\u306e\u6ce8\u5165\u3088\u308b\u30c0\u30e1\u30fc\u30b8\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u975e\u7d50\u5408\u578b\u30ab\u30e9\u30e0\u3001\u90e8\u5206\u7684\u306a\u7d50\u5408\u578b\u30ab\u30e9\u30e0\u3001\u307e\u305f\u306f\u6975\u6027\u30ab\u30e9\u30e0\u306a\u3069\u306e\u56fa\u5b9a\u76f8\u3067\u306f\u3001\u6c34\u5206\u306e\u6ce8\u5165\u306f\u907f\u3051\u308b\u3079\u304d\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3054\u4f7f\u7528\u306e\u30ab\u30e9\u30e0\u304c\u5b8c\u5168\u306b\u67b6\u6a4b\u7d50\u5408\u3055\u308c\u305f\u3082\u306e\u3067\u3042\u308b\u304b\u3069\u3046\u304b\u306f\u3001\u30e1\u30fc\u30ab\u30fc\u306e\u8aac\u660e\u66f8\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002Restek\u793e\u306e\u5834\u5408\u3001\u30ab\u30e9\u30e0\u306e\u540d\u524d\u304cRtx-___\u3001 Stx-___ \u307e\u305f\u306f Rxi-___ \u3067\u59cb\u307e\u308b\u3082\u306e\u306f\u3001\u5b8c\u5168\u306b\u67b6\u6a4b\u7d50\u5408\u3055\u308c\u305f\u3082\u306e\u3067\u3059\u3002\u307e\u305f\u3001\u307b\u3068\u3093\u3069\u306eMXT\u30ab\u30e9\u30e0\u3082\u5b8c\u5168\u306b\u67b6\u6a4b\u7d50\u5408\u3055\u308c\u305f\u30bf\u30a4\u30d7\u306e\u30ab\u30e9\u30e0\u3067\u3059\u3002\u3057\u304b\u3057Restek\u793e\u306e\u30ab\u30e9\u30e0\u3067\u3001Rt-___ \u3067\u59cb\u307e\u308b\u3082\u306e\u306f\u5b8c\u5168\u306b\u306f\u67b6\u6a4b\u7d50\u5408\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u4e00\u822c\u7684\u306b\u306f\u3001\u5b8c\u5168\u306b\u67b6\u6a4b\u7d50\u5408\u3055\u308c\u3066\u3044\u306a\u3044\u30bf\u30a4\u30d7\u306e\u30ab\u30e9\u30e0\u306b\u6c34\u5206\u3092\u6ce8\u5165\u3059\u3079\u304d\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u3044\u304f\u3064\u304b\u306e\u4f8b\u5916\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">1.&nbsp; \u591a\u5b54\u8cea\u306e\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fcPLOT\u30ab\u30e9\u30e0\uff1aRt-Q-Bond\u3001 Rt-QS-Bond\u3001 Rt-S-Bond\u3001\u305d\u3057\u3066Rt-U-Bond\u3068\u547c\u3070\u308c\u3066\u3044\u308b\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fcPLOT\u30ab\u30e9\u30e0(MXT\u30bf\u30a4\u30d7\u3082\u542b\u3081)\u306f\u3001\u6c34\u5206\u306b\u3088\u308b\u30c0\u30e1\u30fc\u30b8\u3092\u53d7\u3051\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u3001Alumina \u307e\u305f\u306f Molecular Sieve PLOT\u30ab\u30e9\u30e0\u306b\u306f\u6c34\u5206\u3092\u6ce8\u5165\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\u3002\u6c34\u306f\u5438\u53ce\u3055\u308c\u3001\u5206\u96e2\u3084\u4fdd\u6301\u6642\u9593\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3057\u307e\u3059\u3002(\u6ce8\uff1a\u6c34\u5206\u306e\u5438\u53ce\u306f\u53ef\u9006\u7684\u3067\u3059\u3002\u4f7f\u7528\u53ef\u80fd\u306a\u6700\u9ad8\u6e29\u5ea6\u3067\u6570\u6642\u9593\u30a8\u30fc\u30b8\u30f3\u30b0\u3059\u308b\u3053\u3068\u3067\u518d\u751f\u3067\u304d\u307e\u3059\u3002)<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">2. \u975e\u7d50\u5408\u578b\u3001\u90e8\u5206\u7684\u306a\u7d50\u5408\u578b\u3001\u307e\u305f\u306f\u6975\u6027\u30ab\u30e9\u30e0\u3067\u6c34\u5206\u3092\u6ce8\u5165\u3059\u308b\u5834\u5408\u3001\u30ab\u30e9\u30e0\u5185\u3067\u6c34\u5206\u304c\u51dd\u7e2e\u3057\u306a\u3044\u3088\u3046\u306b\u30ab\u30e9\u30e0\u6e29\u5ea6\u3092\u5341\u5206\u9ad8\u304f\u4fdd\u3064(80\u2103\u4ee5\u4e0a)\u304b\u3001\u6975\u6027\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u5206\u96e2\u30ab\u30e9\u30e0\u306e\u524d\u306b\u53d6\u4ed8\u3051\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u6c34\u5206\u306f\u6c34\u84b8\u6c17\u306e\u72b6\u614b\u3067\u5206\u96e2\u30ab\u30e9\u30e0\u3078\u5230\u9054\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u8ff0\u306e\u3088\u3046\u306b\u3001\u6c34\u81ea\u4f53\u306f\u307b\u3068\u3093\u3069\u306e\u67b6\u6a4b\u7d50\u5408\u578b\u30ab\u30e9\u30e0\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u4e0e\u3048\u308b\u3053\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u6c34\u6eb6\u6db2\u4e2d\u306b\u542b\u307e\u308c\u308b\u7c92\u5b50\u72b6\u7269\u8cea\u3001\u5869\u3001\u7cd6\u3001\u6eb6\u89e3\u3057\u3066\u3044\u308b\u91d1\u5c5e\u5869\u3084\u6d6e\u904a\u3057\u3066\u3044\u308b\u91d1\u5c5e\u306a\u3069\u306e\u4e0d\u63ee\u767a\u6027\u6210\u5206\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u306e\u52a3\u5316\u304c\u5f15\u304d\u8d77\u3053\u3055\u308c\u3001\u307e\u305f\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u304c\u60aa\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u6c34\u5206\u306e\u5206\u6790\u3067\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u52a3\u5316\u304c\u8d77\u3053\u3063\u305f\u5834\u5408\u3001(\u6ce8\u5165\u53e3\u306e\u30e9\u30a4\u30ca\u30fc\u306b\u6b8b\u7559\u7269\u304c\u6b8b\u3063\u3066\u3044\u306a\u3044\u304b\u3069\u3046\u304b\u78ba\u304b\u3081\u308b\u306a\u3069\u3057\u3066)\u4e0d\u63ee\u767a\u6027\u306e\u4e0d\u7d14\u7269\u304c\u554f\u984c\u3092\u5f15\u304d\u8d77\u3053\u3057\u3066\u3044\u306a\u3044\u304b\u3069\u3046\u304b\u3092\u691c\u8a3c\u3057\u3001\u6ce8\u5165\u524d\u306b\u8a66\u6599\uff0f\u62bd\u51fa\u7269\u304b\u3089\u4e0d\u7d14\u7269\u3092\u53d6\u308a\u9664\u304f\u64cd\u4f5c\u3092\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002\u3053\u308c\u3089\u306e\u64cd\u4f5c\u306f\u3001\u8a66\u6599\u306e\u30af\u30ea\u30fc\u30f3\u30ca\u30c3\u30d7\uff0f\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u3068\u3044\u3046\u524d\u51e6\u7406\u3067\u3067\u304d\u307e\u3059\u3002\u3082\u3057\u3053\u308c\u3089\u306e\u30af\u30ea\u30fc\u30f3\u30ca\u30c3\u30d7\uff0f\u30d5\u30a3\u30eb\u30bf\u30ea\u30f3\u30b0\u3068\u3044\u3046\u524d\u51e6\u7406\u304c\u3067\u304d\u306a\u3044\u5834\u5408\u3001\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb\u307e\u305f\u306fRestek\u793e\u306eCarbofrit \u3092\u5145\u586b\u3057\u305f\u30e9\u30a4\u30ca\u30fc\u306e\u4f7f\u7528\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3053\u307e\u3067\u306b\u8a18\u3057\u305f\u5185\u5bb9\u306f\u3001\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u30e9\u30a4\u30ca\u30fc\u3092\u7528\u3044\u3001\u52a0\u71b1\u3055\u308c\u305f\u30b9\u30d7\u30ea\u30c3\u30c8\uff0f\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u3092\u4f7f\u7528\u3057\u3066\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u5206\u6790\u3092\u304a\u3053\u306a\u3063\u3066\u3044\u308b\u5834\u5408\u3092\u60f3\u5b9a\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u4ee5\u5916\u306e\u6ce8\u5165\u65b9\u6cd5\u3067\u306f\u3001\u6c34\u6eb6\u6027\u8a66\u6599\u306e\u5206\u6790\u306f\u975e\u5e38\u306b\u56f0\u96e3\u3067\u3059\u3002\u4e2d\u3067\u3082\u3001\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u6cd5\u306f\u3001\u3082\u3063\u3068\u3082\u96e3\u3057\u3044\u3082\u306e\u3067\u3059\u3002Restek\u793e\u306e\u30c6\u30af\u30cb\u30ab\u30eb\u30b5\u30dd\u30fc\u30c8\u90e8\u9580\u3067\u306f\u3001\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u6cd5\u3067\u306e\u6c34\u5206\u306e\u6ce8\u5165\u306f\u304a\u52e7\u3081\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u6cd5\u3067\u6c34\u5206\u3092\u6ce8\u5165\u3057\u3066\u3001\u554f\u984c\u306a\u304f\u826f\u3044\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3068\u518d\u73fe\u6027\u306e\u3042\u308b\u7d50\u679c\u3092\u5f97\u3066\u3044\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u304c\u3001\u305f\u3044\u3066\u3044\u306e\u5834\u5408\u3001\u89e3\u6c7a\u3059\u308b\u3053\u3068\u306e\u3067\u304d\u306a\u3044\u591a\u304f\u306e\u554f\u984c\u70b9\u3092\u62b1\u3048\u3066\u3044\u307e\u3059\u3002GC\u306e\u30aa\u30fc\u30d6\u30f3\u3067\u3057\u304b\u52a0\u71b1\u3067\u304d\u306a\u3044\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u6cd5\u3067\u306f\u4ee5\u4e0a\u306e\u3053\u3068\u306f\u9855\u8457\u3067\u3001GC\u306e\u30aa\u30fc\u30d6\u30f3\u3068\u306f\u72ec\u7acb\u3057\u3066\u52a0\u71b1\u3067\u304d\u308b\u30bf\u30a4\u30d7\u306e\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u53e3\u3067\u306f\u3053\u306e\u9650\u308a\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30aa\u30f3\u30ab\u30e9\u30e0\u6ce8\u5165\u3067\u306e\u6c34\u5206\u306e\u5206\u6790\u306e\u5834\u5408\u3001\u5b8c\u5168\u67b6\u6a4b\u578b\u306e\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u3066\u3044\u3066\u3082\u3001\u6975\u6027\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6e08\u307f\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u3053\u306e\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0(\u30ea\u30c6\u30f3\u30b7\u30e7\u30f3\u30fb\u30ae\u30e3\u30c3\u30d7)\u306f\u3001\u7121\u6975\u6027\u306e\u30ab\u30e9\u30e0\u6db2\u76f8\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u306e\u30ab\u30e9\u30e0\u5185\u8868\u9762\u306e\u6fe1\u308c\u3092\u6539\u5584\u3057\u3001\u3055\u3089\u306b\u3001\u30ab\u30e9\u30e0\u306b\u4e0d\u63ee\u767a\u6027\u6210\u5206\u304c\u5165\u308b\u306e\u3092\u9632\u6b62\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b7\u30ea\u30f3\u30b8\u3067\u6c34\u6eb6\u6027\u8a66\u6599\u3092\u5206\u6790\u3059\u308b\u5834\u5408\u306e\u3044\u304f\u3064\u304b\u306e\u6ce8\u610f\u70b9\u3092\u4ee5\u4e0b\u306b\u307e\u3068\u3081\u3066\u307f\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><em>\u307e\u305a\u6700\u521d\u306b\u3001\u30d0\u30c3\u30af\u30d5\u30e9\u30c3\u30b7\u30e5\u3092\u5e38\u306b\u8003\u3048\u3066\u304f\u3060\u3055\u3044\u3002\u6c34\u306f\u6c17\u5316\u3059\u308b\u3068\u4f53\u7a4d\u304c1400\u500d\u306b\u81a8\u5f35\u3057\u307e\u3059\u3002\u6ce8\u5165\u91cf\u306f\u51fa\u6765\u308b\u9650\u308a\u5c11\u306a\u304f\uff080.5\u00b5L\u4ee5\u4e0b\uff09\u3057\u3001\u30e9\u30a4\u30ca\u30fc\u306f\u3001GC\u3067\u4f7f\u7528\u3067\u304d\u308b\u6700\u5927\u306e\u5f84\u306e\u3082\u306e\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/em><\/li>\n\n\n\n<li><em>\u6b21\u3044\u3067\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3042\u308b\u3044\u306f\u76f4\u63a5\u6ce8\u5165\u3088\u308a\u3082\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u6bd4\u306e\u5927\u304d\u3044\u30b9\u30d7\u30ea\u30c3\u30c8\u6ce8\u5165\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/em><\/li>\n\n\n\n<li><em>3<\/em><em>\u3064\u76ee\u306f\u3001\u3088\u308a\u826f\u3044\u518d\u73fe\u6027\u3092\u5f97\u308b\u305f\u3081\u306b\u3001\u30d7\u30e9\u30f3\u30b8\u30e3\u306e\u5148\u7aef\u306bPTFE\u306e\u30c1\u30c3\u30d7\u304c\u7740\u3044\u305f\u30ac\u30b9\u30bf\u30a4\u30c8\u30b7\u30ea\u30f3\u30b8\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3059\u3002<\/em><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u201c\u30ad\u30e3\u30d4\u30e9\u30eaGC\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u3092\u52a3\u5316\u3055\u305b\u308b\u3082\u306e\u201d\u306f\u3059\u3079\u3066\u306e\u554f\u984c\u3092\u7db2\u7f85\u3057\u3066\u3044\u308b\u8a33\u3067\u306f\u306a\u304f\u3001\u30ab\u30e9\u30e0\u306b\u30c0\u30e1\u30fc\u30b8\u3092\u3044\u304f\u3064\u304b\u306e\u72b6\u6cc1\u3092\u8a73\u3057\u304f\u89e3\u8aac\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u3089\u306e\u60c5\u5831\u306b\u3088\u308a\u3001\u5206\u6790\u8005\u304c\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3059\u308b\u3053\u3068\u306e\u3067\u304d\u308b\u3044\u304f\u3064\u304b\u306e\u8981\u56e0\u304b\u3089\u3001\u30ab\u30e9\u30e0\u3092\u4fdd\u8b77\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u3088\u3046\u3088\u3046\u306b\u306a\u308c\u3070\u5e78\u3044\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Aqueous Injections In my final installment of Capillary GC Column Killers, I would like to discuss aqueous (water) injections. There are a lot of misconceptions about injecting water into a GC, and for good reason. Besides the general knowledge that&#8230;<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340,2342],"ppma_author":[2823],"class_list":["post-48556","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-injection-techniques-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2342,"label":"\u6ce8\u5165\u65b9\u6cd5"}]},"featured_image_src_large":false,"author_info":{"display_name":"DRCadmin","author_link":"https:\/\/discover.restek.com\/ja\/author\/drcadmin\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48556","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48556"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48556\/revisions"}],"predecessor-version":[{"id":64049,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48556\/revisions\/64049"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48556"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48556"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48556"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48556"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48556"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48556"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48556"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48556"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48556"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}