{"id":48558,"date":"2013-06-26T14:30:00","date_gmt":"2013-06-26T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-why-leak-check-your-gc-system\/"},"modified":"2025-11-24T16:57:52","modified_gmt":"2025-11-24T16:57:52","slug":"japanese-why-leak-check-your-gc-system","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4877-ja\/japanese-why-leak-check-your-gc-system","title":{"rendered":"\u306a\u305cGC\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u304c\u5fc5\u8981\u306a\u306e\u3067\u3057\u3087\u3046\u304b\uff1f"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">The original English blog\u00a0was posted on June 26th, 2013 by\u00a0Tom Bloom<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3042\u307e\u308a\u306b\u3082\u983b\u7e41\u306b\u3001\u5206\u6790\u62c5\u5f53\u8005\u304b\u3089\u300c\u79c1\u306eGC\u30b7\u30b9\u30c6\u30e0\u306b\u306f\u30ea\u30fc\u30af\u306f\u3042\u308a\u307e\u305b\u3093\u300d\u3068\u805e\u304d\u307e\u3059\u3002\u3057\u304b\u3057\u3069\u3093\u306a\u30c4\u30fc\u30eb\u304c\u3042\u308c\u3070\u5206\u6790\u30b7\u30b9\u30c6\u30e0\u304c\u672c\u5f53\u306b\u30ea\u30fc\u30af\u3057\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308b\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u5206\u6790\u6027\u80fd\u3092\u5411\u4e0a\u3055\u305b\u3001\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u3092\u6700\u5c0f\u306b\u6291\u3048\u3001\u30ab\u30e9\u30e0\u3084\u9ad8\u611f\u5ea6\u691c\u51fa\u5668\u306e\u30c0\u30e1\u30fc\u30b8\u3092\u9632\u3050\u305f\u3081\u3001\u65e5\u5e38\u70b9\u691c\u306b\u96fb\u5b50\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u7d44\u307f\u8fbc\u3080\u3053\u3068\u3092\u5f37\u304f\u304a\u52e7\u3081\u3044\u305f\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ea\u30fc\u30af\u306e\u30c1\u30a7\u30c3\u30af\u3092\u91cd\u8981\u306a\u30c8\u30e9\u30d6\u30eb\u9632\u6b62\u306e\u4fdd\u5b88\u7ba1\u7406\u3084\u30e9\u30dc\u306e\u7ba1\u7406\u57fa\u6e96\u3068\u3057\u3066\u8003\u3048\u308b\u3068\uff0c\u5b9f\u65bd\u3057\u306a\u3044\u308f\u3051\u306b\u306f\u3044\u304d\u307e\u305b\u3093\u3002\u30ea\u30fc\u30af\u304c\u9ad8\u4fa1\u306a\u9ad8\u7d14\u5ea6\u30ac\u30b9\u3092\u7121\u99c4\u306b\u3057\u305f\u308a\u3001\u30c8\u30e9\u30c3\u30d7\u3084\u7cbe\u88fd\u7ba1\u306e\u5bff\u547d\u3092\u7e2e\u3081\u305f\u308a\u3001\u30ab\u30e9\u30e0\u3092\u7834\u640d\u3057\u305f\u308a\u3001\u30b7\u30b9\u30c6\u30e0\u3084\u691c\u51fa\u5668\u306e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u983b\u5ea6\u304c\u5897\u3048\u308b\u3068\u3044\u3063\u305f\u3053\u3068\u306e\u539f\u56e0\u3068\u306a\u308b\u3053\u3068\u3092\u3054\u7559\u610f\u304f\u3060\u3055\u3044\u3002\u3055\u3089\u306b\u3001ECD\u306a\u3069\u3044\u304f\u3064\u304b\u306e\u691c\u51fa\u5668\u306f\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u304b\u3089\u9178\u7d20\u306b\u66dd\u3055\u308c\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u91cd\u5927\u306a\u30c0\u30e1\u30fc\u30b8\u3092\u53d7\u3051\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"141\" height=\"202\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-why-leak-check-your-gc-system-01.jpg\" alt=\"\" class=\"wp-image-17781\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><em><strong>\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u306b\u3088\u308a<\/strong><\/em>\u591a\u304f\u306e\u4e00\u822c\u7684\u306a\u5206\u6790\u306b\u304a\u3051\u308b\u554f\u984c\u3092\u907f\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u30ea\u30fc\u30af\u304c\u983b\u7e41\u3067\uff08\u591a\u5c11\u306f\uff09\u308f\u304b\u308a\u3084\u3059\u3044HPLC\u30b7\u30b9\u30c6\u30e0\u3068\u306f\u9055\u3044\u3001GC\u30b7\u30b9\u30c6\u30e0\u3067\u306e\u30ea\u30fc\u30af\u306f\u6349\u3048\u306b\u304f\u304f\u9069\u5207\u306a\u6a5f\u5668\u306a\u3057\u3067\u306f\u7279\u5b9a\u3059\u308b\u3053\u3068\u304c\u96e3\u3057\u3044\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u6e90\u3084\u30ec\u30ae\u30e5\u30ec\u30fc\u30bf\u30fc\u304b\u3089\u59cb\u3081\u3066\u3001GC\u3078\u306e\u6d41\u8def\u306b\u6cbf\u3063\u3066\u5404\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3084\u63a5\u7d9a\u90e8\u3092\u614e\u91cd\u306b\u30c1\u30a7\u30c3\u30af\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30aa\u30fc\u30d6\u30f3\u30d5\u30a1\u30f3\u3092\u6b62\u3081\u3066\u3001\u30aa\u30fc\u30d6\u30f3\u5185\u3082\u542b\u3081\u3066\u3059\u3079\u3066\u306e\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3084\u30a2\u30c0\u30d7\u30bf\u3001\u63a5\u7d9a\u90e8\u3082\u30c1\u30a7\u30c3\u30af\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u3055\u3089\u306b\uff0c\u30d7\u30ec\u30b9\u30bf\u30a4\u30c8\u30b3\u30cd\u30af\u30bf\u3084\u30e6\u30cb\u30aa\u30f3\u3068\u3044\u3063\u305f\u3001\u3059\u3079\u3066\u306e\u30ab\u30e9\u30e0\u3068\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u306e\u63a5\u7d9a\u90e8\u3082\u5fd8\u308c\u305a\u30c1\u30a7\u30c3\u30af\u3057\u3066\u304f\u3060\u3055\u3044\u3002\u30ea\u30fc\u30af\u3092\u8fbf\u3063\u3066\u3044\u304f\u3068\u3001\u63a5\u7d9a\u6642\u306b\u62bc\u3057\u3064\u3076\u3057\u3066\u3057\u307e\u3063\u305f\u308a\u3001\u6b63\u3057\u304f\u63a5\u7d9a\u3055\u308c\u3066\u3044\u306a\u3044\u30ab\u30e9\u30e0\u306e\u7aef\u3078\u3068\u305f\u3069\u308a\u7740\u304f\u3053\u3068\u304c\u591a\u3005\u3042\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u3092\u30c1\u30a7\u30c3\u30af\u3059\u308b<em><strong>\u6700\u5584\u306e<\/strong><\/em>\u65b9\u6cd5\u306f\u3001\u6700\u65b0\u578b\u306eRestek Electronic Leak Detector (cat.# 28500)\u306e\u3088\u3046\u306a\u71b1\u4f1d\u5c0e\u7387\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u30dd\u30fc\u30bf\u30d6\u30eb\u3067\u4fe1\u983c\u6027\u304c\u3042\u308a\u3001\u3042\u307e\u308a\u9ad8\u4fa1\u3067\u306a\u3044\u624b\u6301\u3061\u5f0f\u306e\u6a5f\u5668\u306f\u30b7\u30b9\u30c6\u30e0\u3092\u6c5a\u67d3\u3059\u308b\u3053\u3068\u306a\u304f\u5fae\u91cf\u306e\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u3092\u691c\u51fa\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\u8a18\uff1aGC\/MS\u88c5\u7f6e\u3067\u306e\u30ea\u30fc\u30af\u306f\u8cea\u91cf\u657028(\u7a92\u7d20)\u3082\u3057\u304f\u306f\u8cea\u91cf\u657032(\u9178\u7d20)\u3092\u30e2\u30cb\u30bf\u30fc\u3059\u308b\u304b\u3001\u3082\u3057\u304f\u306f\u30a2\u30eb\u30b4\u30f3\u30ac\u30b9\u3092\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3084\u63a5\u7d9a\u90e8\u306e\u5468\u56f2\u306b\u5439\u304d\u4ed8\u3051\u3066\u8cea\u91cf\u657040\u3092\u30e2\u30cb\u30bf\u30fc\u3059\u308b\u3053\u3068\u3067\u691c\u77e5\u3057\u307e\u3059\u3002\u3082\u3057\u304f\u306f\uff0c\u8cea\u91cf\u5206\u6790\u62c5\u5f53\u8005\u306e\u591a\u304f\u306f\u30a2\u30eb\u30b4\u30f3\u306e\u4ee3\u308f\u308a\u306b\u30a8\u30a2\u30c0\u30b9\u30bf\u30fc\u7f36\u3092\u4f7f\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u88fd\u54c1\u306f\u5b89\u4fa1\u3067\u3059\u3050\u306b\u5165\u624b\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"225\" height=\"226\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-why-leak-check-your-gc-system-02.jpg\" alt=\"\" class=\"wp-image-17787\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-why-leak-check-your-gc-system-02.jpg 225w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-why-leak-check-your-gc-system-02-150x150.jpg 150w\" sizes=\"auto, (max-width: 225px) 100vw, 225px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\u8a18\uff1a\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u304a\u3044\u3066\u306f\uff0c\u77f3\u3051\u3093\u3084\u754c\u9762\u6d3b\u6027\u5264\u3092\u542b\u3093\u3060<em><strong>\u6f0f\u308c\u691c\u51fa\u6db2\u3092\u7d76\u5bfe\u4f7f\u7528\u3057\u306a\u3044<\/strong><\/em>\u3088\u3046\u306b\u5f37\u304f\u304a\u9858\u3044\u3057\u3066\u3044\u307e\u3059\u3002\u30ea\u30fc\u30af\u306f\u691c\u51fa\u6db2\u306b\u542b\u307e\u308c\u308b\u7269\u8cea\u3092\u30b7\u30b9\u30c6\u30e0\u306b\u5f15\u304d\u8fbc\u307f\u30ab\u30e9\u30e0\u6c5a\u67d3\u3092\u5f15\u304d\u8d77\u3053\u3057\u305f\u308a\u3001\u9ad8\u611f\u5ea6\u5206\u6790\u3092\u96e3\u3057\u304f\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u77f3\u3051\u3093\u30d9\u30fc\u30b9\u306e\u6f0f\u308c\u691c\u51fa\u6db2\u306f\u6db2\u76f8\u306b\u4e0d\u53ef\u9006\u7684\u306a\u30c0\u30e1\u30fc\u30b8\u3092\u8d77\u3053\u3059\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u71b1\u4f1d\u5c0e\u7387\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u304c\u5229\u7528\u3067\u304d\u306a\u3044\u5834\u5408\u3001<strong>\u5727\u529b\u5c01\u5165\u30ea\u30fc\u30af\u30c6\u30b9\u30c8<\/strong>\u3067\u3082\u4e3b\u8981\u306a\u30ac\u30b9\u306e\u30ea\u30fc\u30af\u3092\u898b\u3064\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u306e\u65b9\u6cd5\u306f\u7814\u7a76\u65bd\u8a2d\u3067\u306e\u9577\u3044\u30ac\u30b9\u4f9b\u7d66\u914d\u7ba1\u3092\u30c1\u30a7\u30c3\u30af\u3059\u308b\u3068\u304d\u306b\u975e\u5e38\u306b\u6709\u7528\u3067\u3059\u3002\u6b8b\u5ff5\u306a\u304c\u3089\u3053\u306e\u8a66\u9a13\u306f\u3069\u3053\u304b\u306b\u30ea\u30fc\u30af\u304c\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u306f\u6709\u52b9\u3067\u3059\u304c\u3001\u30ea\u30fc\u30af\u306e\u767a\u751f\u7b87\u6240\u3092\u7279\u5b9a\u3059\u308b\u3053\u3068\u306f\u56f0\u96e3\u3067\u3059\u3002\u305d\u3046\u3001\u30ea\u30fc\u30af\u306f\u5b58\u5728\u3059\u308b\u306e\u3067\u3059\u3002\u3067\u3082\uff0c\u3069\u3053\u306a\u306e\u3067\u3057\u3087\u3046\u304b\uff1f<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u3068\u3081\u308b\u3068\u3001GC\u3092\u6709\u3059\u308b\u3059\u3079\u3066\u306e\u30e9\u30dc\u3067\u306f\u96fb\u5b50\u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf\u3092\u5099\u3048\u308b\u3079\u304d\u3067\u3042\u308a\u3001\u3059\u3079\u3066\u306e\u5206\u6790\u62c5\u5f53\u8005\u306f\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3084\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u53d6\u308a\u4ed8\u3051\u305f\u308a\u3001\u30dc\u30f3\u30d9\u3092\u4ea4\u63db\u3057\u305f\u308a\u3001\u6a5f\u5668\u306e\u30c8\u30e9\u30d6\u30eb\u30b7\u30e5\u30fc\u30c6\u30a3\u30f3\u30b0\u3092\u6307\u793a\u3055\u308c\u305f\u969b\u306b\u306f\u3044\u3064\u3067\u3082\u3053\u306e\u9053\u5177\u3092\u4f7f\u7528\u3067\u304d\u308b\u3088\u3046\u30c8\u30ec\u30fc\u30cb\u30f3\u30b0\u3092\u53d7\u3051\u308b\u3079\u304d\u3067\u3059\u3002\u30ab\u30e9\u30e0\u3084\u691c\u51fa\u5668\u3078\u30c0\u30e1\u30fc\u30b8\u4e0e\u3048\u308b\u53ef\u80fd\u6027\u3092\u6700\u5c0f\u9650\u3068\u3059\u308b\u305f\u3081\u306b\u3001<strong>\u306f\u3058\u3081\u306b\u30b7\u30b9\u30c6\u30e0\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u3057\u306a\u3044\u307e\u307e\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u3092\u3057\u306a\u3044\u3067\u304f\u3060\u3055\u3044\uff01<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u983b\u7e41\u306b\u3001\u5fb9\u5e95\u7684\u306b\u3001\u614e\u91cd\u306b\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3046\u3053\u3068\u3067GC\u30b7\u30b9\u30c6\u30e0\u306e\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u6d41\u8def\u5168\u4f53\u306b\u6b20\u9665\u304c\u306a\u3044\u3053\u3068\u3092\u7acb\u8a3c\u3067\u304d\u3001\u9ad8\u4fa1\u306a\u30ab\u30e9\u30e0\u3078\u306e\u30c0\u30e1\u30fc\u30b8\u3092\u9632\u304e\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u3042\u307e\u308a\u306b\u3082\u983b\u7e41\u306b\u3001\u5206\u6790\u62c5\u5f53\u8005\u304b\u3089\u300c\u79c1\u306eGC\u30b7\u30b9\u30c6\u30e0\u306b\u306f\u30ea\u30fc\u30af\u306f\u3042\u308a\u307e\u305b\u3093\u300d\u3068\u805e\u304d\u307e\u3059\u3002\u3057\u304b\u3057\u3069\u3093\u306a\u30c4\u30fc\u30eb\u304c\u3042\u308c\u3070\u5206\u6790\u30b7\u30b9\u30c6\u30e0\u304c\u672c\u5f53\u306b\u30ea\u30fc\u30af\u3057\u3066\u3044\u306a\u3044\u3053\u3068\u304c\u308f\u304b\u308b\u306e\u3067\u3057\u3087\u3046\u304b&hellip;<\/p>\n","protected":false},"author":57,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[612],"class_list":["post-48558","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Tom Bloom","author_link":"https:\/\/discover.restek.com\/ja\/author\/tom-bloom\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":456,"filter":"raw","cat_ID":794,"category_count":456,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":612,"user_id":57,"is_guest":0,"slug":"tom-bloom","display_name":"Tom Bloom","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Tom","last_name":"Bloom","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48558","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/57"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48558"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48558\/revisions"}],"predecessor-version":[{"id":68178,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48558\/revisions\/68178"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48558"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48558"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48558"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48558"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48558"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48558"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48558"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48558"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48558"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}