{"id":48559,"date":"2014-02-04T13:30:00","date_gmt":"2014-02-04T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-japan\/"},"modified":"2025-11-24T17:01:28","modified_gmt":"2025-11-24T17:01:28","slug":"simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4796-ja\/simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-japan","title":{"rendered":"\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u6c34\u7d20\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3078\u306eGC\u30e1\u30bd\u30c3\u30c9\u5909\u63db\u306b\u3064\u3044\u3066"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u904e\u53bb\u306ePittCon\u3067Restek\u306f\u3001\u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac\u306e\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u5206\u6790\u306b\u304a\u3051\u308b\u6c34\u7d20\u304a\u3088\u3073\u7a92\u7d20\u3092\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3064\u3044\u3066\u3001\u30d7\u30ec\u30bc\u30f3\u30c6\u30fc\u30b7\u30e7\u30f3\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u306e\u30d7\u30ec\u30bc\u30f3\u30c6\u30fc\u30b7\u30e7\u30f3\u3067Restek\u306f\u3001\u6c34\u7d20\u3092\u4f7f\u7528\u3059\u308b\u3068\u304d\u3068\u540c\u3058\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u3067\u3001\u6c34\u7d20\u3068\u540c\u69d8\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u5f97\u306a\u304c\u3089\u3001\u6c34\u7d20\u3068\u540c\u3058\u7dda\u901f\u5ea6\u3067\u7a92\u7d20\u306b\u7f6e\u63db\u3059\u308b\u65b9\u6cd5\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u6b8b\u5ff5\u306a\u3053\u3068\u306b\u7a92\u7d20\u306e\u5834\u5408\u3001\u30d4\u30fc\u30af\u306f\u5e83\u304c\u308a\u3001\u30d4\u30fc\u30af\u306e\u5206\u96e2\u306f\u60aa\u304f\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u7f6e\u63db\u304c\u6210\u529f\u3059\u308b\u8981\u56e0\u306e\u4e00\u3064\u3068\u3057\u3066\u3001Rtx-CLPesticides GC\u30ab\u30e9\u30e0\u304c\u6709\u6a5f\u5869\u7d20\u7cfb\u8fb2\u85ac\u306b\u5bfe\u3057\u3066\u512a\u308c\u305f\u9078\u629e\u6027\u3092\u6301\u3063\u3066\u3044\u308b\u3053\u3068\u304c\u6319\u3052\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Jaap de Zeeuw\u6c0f\u304b\u3089\u3001\u30d8\u30ea\u30a6\u30e0\u3092\u6c34\u7d20\u306b\u7f6e\u63db\u3057\u305f\u5834\u5408\u306b\u95a2\u3057\u3066\u3082\u3001\u7a92\u7d20\u3092\u6c34\u7d20\u306b\u7f6e\u63db\u3057\u3066\u884c\u3063\u305f\u306e\u3068\u540c\u69d8\u306e\u5b9f\u9a13\u3092\u884c\u3063\u3066\u307b\u3057\u3044\u3068\u3044\u3046\u4f9d\u983c\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u304a\u305d\u3089\u304f\u6c34\u7d20\u306e\u7dda\u901f\u5ea6\u306f\u6700\u9069\u5e73\u5747\u7dda\u901f\u5ea6\u3092\u4e0b\u56de\u308b\u306e\u3067\u3001\u5206\u96e2\u306e\u640d\u5931\u304c\u767a\u751f\u3059\u308b\u306e\u3067\u306f\u306a\u3044\u304b\u3001\u305d\u308c\u3092\u78ba\u8a8d\u3057\u305f\u3044\u3068\u306e\u3053\u3068\u3067\u3057\u305f\u3002\u5b9f\u9a13\u7d50\u679c\u3068\u3057\u3066\u3001\u5206\u96e2\u306e\u5b9f\u8cea\u7684\u306a\u640d\u5931\u306f\u306a\u304b\u3063\u305f\u3068\u3044\u3053\u3068\u3092\u3053\u3053\u3067\u7d39\u4ecb\u3067\u304d\u308b\u306e\u306f\u559c\u3070\u3057\u3044\u3053\u3068\u3067\u3059\u3002Restek Method Translator\u3092\u4f7f\u7528\u3057\u3066\u3001\u6c34\u7d20\u306e\u7dda\u901f\u5ea6\u3092\u30d8\u30ea\u30a6\u30e0\u306eSpeed Optimized Flow\u304b\u3089\u53d6\u5f97\u3057\u305f\u5143\u306e\u7dda\u901f\u5ea6\u3068\u4e00\u81f4\u3055\u305b\u3001GC\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u540c\u69d8\u306e\u6570\u5024\u306b\u4fdd\u3061\u307e\u3057\u305f\u3002Restek\u306e\u30d8\u30ea\u30a6\u30e0\u3092\u4f7f\u3063\u305f\u30e1\u30bd\u30c3\u30c9\u3068\u6c34\u7d20\u3092\u4f7f\u3063\u305f\u30e1\u30bd\u30c3\u30c9\u306b\u304a\u3044\u3066\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u307b\u307c\u540c\u4e00\u3067\u3059\u304c\u3001Agilent \u00b5-ECD\u3067\u6c34\u7d20\u3092\u4f7f\u7528\u3057\u305f\u5834\u5408\u3001\u30ec\u30b9\u30dd\u30f3\u30b9\u306f\u7d04\u534a\u5206\u306b\u6e1b\u5c11\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30a2\u30d7\u30ed\u30fc\u30c1\u306f\u4eba\u3005\u304cGC\u5206\u6790\u306b\u304a\u3044\u3066\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u6c34\u7d20\u306b\u5207\u308a\u66ff\u3048\u308b\u969b\u306e\u30cf\u30fc\u30c9\u30eb\u3092\u4e0b\u3052\u308b\u306e\u3067\u306f\u306a\u3044\u304b\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u5f8c\u3082\u6700\u65b0\u60c5\u5831\u3092\u304a\u5c4a\u3051\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\uff01<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"770\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-01-1024x770.jpg\" alt=\"\" class=\"wp-image-16797\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-01-1024x770.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-01-300x226.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-01-768x578.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-01.jpg 1482w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"alignleft size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"769\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-02-1024x769.jpg\" alt=\"\" class=\"wp-image-16803\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-02-1024x769.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-02-300x225.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-02-768x577.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-simple-translation-of-gc-methods-from-helium-to-hydrogen-carrier-gas-02.jpg 1480w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>GC\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u30d8\u30ea\u30a6\u30e0\u304b\u3089\u6c34\u7d20\u306b\u5909\u66f4\u3057\u3066\u3082\u5b9f\u8cea\u7684\u306b\u5206\u96e2\u306e\u640d\u5931\u306f\u306a\u304b\u3063\u305f\u3053\u3068\u3092\u5b9f\u969b\u306e\u5b9f\u9a13\u7d50\u679c\u3068\u3068\u3082\u306b\u8aac\u660e\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[2289,2272,2271,2273,2275,2274,2287],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[590],"class_list":["post-48559","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","industries-application-soil-sediment-biota-testing-ja","industries-application-air-monitoring-ja","industries-application-environmental-ja","industries-application-industrial-hygiene-ja","industries-application-food-safety-ja","industries-application-food-beverage-ja","industries-application-drinking-water-wastewater-testing-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"industries-application":[{"value":2289,"label":"\u571f\u58cc\uff5c\u5e95\u8cea\uff5c\u751f\u7269\u8a66\u6599 \u5206\u6790"},{"value":2272,"label":"\u5927\u6c17 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2273,"label":"\u7523\u696d\u885b\u751f"},{"value":2275,"label":"\u98df\u306e\u5b89\u5168"},{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"DRCadmin","author_link":"https:\/\/discover.restek.com\/ja\/author\/drcadmin\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":590,"user_id":0,"is_guest":1,"slug":"jack-cochran","display_name":"Jack Cochran","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48559","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48559"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48559\/revisions"}],"predecessor-version":[{"id":68181,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48559\/revisions\/68181"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48559"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48559"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48559"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48559"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48559"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48559"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48559"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48559"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48559"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}