{"id":48560,"date":"2025-04-15T00:00:00","date_gmt":"2025-04-15T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/inert-lc-columns-the-answer-to-poor-thc-sensitivity-japan\/"},"modified":"2026-01-21T18:48:26","modified_gmt":"2026-01-21T18:48:26","slug":"inert-lc-columns-the-answer-to-poor-thc-sensitivity-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4715-ja\/inert-lc-columns-the-answer-to-poor-thc-sensitivity-japan","title":{"rendered":"\u5168\u8840\u4e2d\u306eTHC\u9ad8\u611f\u5ea6\u5206\u6790\u3068\u30a4\u30ca\u30fc\u30c8LC\u30ab\u30e9\u30e0\u306e\u6709\u52b9\u6027"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">LC-MS\/MS\u306b\u3088\u308b\u5168\u8840\u4e2d\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u5206\u6790\u306f\u3001\u3055\u307e\u3056\u307e\u306a\u8981\u56e0\u306b\u3088\u308a\u975e\u5e38\u306b\u96e3\u6613\u5ea6\u304c\u9ad8\u304f\u3001\u306a\u304b\u3067\u3082\u5831\u544a\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u3067\u6c42\u3081\u3089\u308c\u308b\u6975\u3081\u3066\u4f4e\u3044\u691c\u51fa\u9650\u754c\u3092\u9054\u6210\u3059\u308b\u3053\u3068\u304c\u6700\u5927\u306e\u8ab2\u984c\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u591a\u304f\u306e\u6cd5\u533b\u5b66\u7814\u7a76\u6240\u3067\u306f\u3001\u03949-\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb\uff08\u03949-THC\uff09\u3084\u300111-\u30d2\u30c9\u30ed\u30ad\u30b7-\u03949-THC\uff0811-OH-\u03949-THC\uff09\u300111-\u30ce\u30eb-9-\u30ab\u30eb\u30dc\u30ad\u30b7-\u03949-THC\uff08\u03949-THC-COOH\uff09\u3068\u3044\u3063\u305f\u91cd\u8981\u306a\u4ee3\u8b1d\u7269\u306b\u3064\u3044\u3066\u30010.5ng\/mL\u4ee5\u4e0b\u306e\u5b9a\u91cf\u4e0b\u9650\uff08LOQ\uff09\u9054\u6210\u3092\u76ee\u6a19\u3068\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u3053\u3046\u3057\u305f\u4f4e\u3044\u691c\u51fa\u9650\u754c\u306e\u9054\u6210\u306f\u3001\u7279\u306b\u611f\u5ea6\u306e\u4f4e\u3044\u65e7\u578b\u88c5\u7f6e\u3067\u306f\u975e\u5e38\u306b\u56f0\u96e3\u3067\u3059\u3002\u5f93\u6765\u306e\u611f\u5ea6\u5411\u4e0a\u7b56\u3092\u3059\u3079\u3066\u8a66\u3057\u3066\u3082\u306a\u304a\u3001\u5341\u5206\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u306a\u3044\u5834\u5408\u306b\u306f\u3001\u30a4\u30ca\u30fc\u30c8LC\u30ab\u30e9\u30e0\u306e\u5c0e\u5165\u3092\u305c\u3072\u3054\u691c\u8a0e\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a4\u30ca\u30fc\u30c8LC\u30ab\u30e9\u30e0\u306e\u69cb\u9020\u306f\u5f93\u6765\u306e\u30b9\u30c6\u30f3\u30ec\u30b9\u88fdLC\u30ab\u30e9\u30e0\u3068\u540c\u69d8\u3067\u3059\u304c\u3001\u8868\u9762\u306b\u4e0d\u6d3b\u6027\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u304c\u65bd\u3055\u308c\u3066\u3044\u308b\u70b9\u3067\u7570\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u306f\u3001\u91d1\u5c5e\u8868\u9762\u306b\u5bfe\u3059\u308b\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u30ad\u30ec\u30fc\u30c8\u5316\u3084\u5438\u7740\u306a\u3069\u306e\u975e\u7279\u7570\u7684\u7d50\u5408\u3092\u9632\u3050\u5f79\u5272\u3092\u6301\u3061\u307e\u3059\u3002\u30ad\u30ec\u30fc\u30c8\u5316\u304c\u8d77\u3053\u308b\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u60aa\u5316\u3057\u305f\u308a\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u640d\u5931\u306b\u3088\u308a\u691c\u51fa\u611f\u5ea6\u304c\u4f4e\u4e0b\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u304c\u975e\u7279\u7570\u7684\u7d50\u5408\uff08\u30ad\u30ec\u30fc\u30c8\u5316\uff09\u3092\u8d77\u3053\u3059\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u7279\u306b\u9178\u6027\u5316\u5408\u7269\u306f\u30ad\u30ec\u30fc\u30c8\u5316\u3057\u3084\u3059\u3044\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u3059\u3079\u3066\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3067\u9055\u3044\u304c\u51fa\u308b\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u691c\u51fa\u611f\u5ea6\u306e\u5411\u4e0a\u306f\u671f\u5f85\u3067\u304d\u307e\u3059\u3002\u4ee5\u4e0b\u306e\u5b9f\u9a13\u3067\u306f\u3001\u5168\u8840\u4e2d\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u5206\u6790\u306b\u30a4\u30ca\u30fc\u30c8LC\u30ab\u30e9\u30e0\u3068\u5f93\u6765\u306e\u30b9\u30c6\u30f3\u30ec\u30b9\u88fd\u30ab\u30e9\u30e0\u3092\u7528\u3044\u3066\u3001\u305d\u308c\u305e\u308c\u306e\u6027\u80fd\u3092\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u958b\u767a\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001Raptor FluoroPhenyl\u56fa\u5b9a\u76f8\u3092\u5229\u7528\u3057\u3001\u03948-THC\u3001\u03949-THC\u304a\u3088\u3073\u305d\u308c\u3089\u306e\u30d2\u30c9\u30ed\u30ad\u30b7\u30fb\u30ab\u30eb\u30dc\u30ad\u30b7\u4ee3\u8b1d\u7269\u3092\u5206\u96e2\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u306e\u6709\u52b9\u6027\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306b\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u3092Raptor Inert FluoroPhenyl\u30ab\u30e9\u30e0\u3068Raptor FluoroPhenyl\u30ab\u30e9\u30e0\uff08\u6a19\u6e96\u30ab\u30e9\u30e0\uff09\u306e\u4e21\u65b9\u3067\u76ee\u7684\u6210\u5206\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790\u3092\u5b9f\u884c\u3057\u3001\u305d\u306e\u7d50\u679c\u3092\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> Raptor FluoroPhenyl\u30ab\u30e9\u30e0\u3068Raptor Inert FluoroPhenyl\u30ab\u30e9\u30e0\u3067\u306e\u03949-THC\u3001\u03948-THC\u3001\u304a\u3088\u3073\u4ee3\u8b1d\u7269\u306e\u5206\u6790\u7d50\u679c\u6bd4\u8f03\uff08\u5206\u6790\u6761\u4ef6\u306f\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0829.png\" alt=\"Comparison of \u03949-THC; \u03948-THC; and Metabolites on Raptor FluoroPhenyl vs. Raptor Inert FluroPhenyl\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_CF0829<\/p><div class=\"chromatogram-peaks\"><h4>Peaks<\/h4><table class=\"peaks col-lg-6 col-12\">\n<thead><tr><th><\/th><th style=\"text-align: left;width: 75px\">Peaks<\/th><th style=\"text-align: center;width: 75px\">Conc.<br \/>(ng\/mL)<\/th><th style=\"text-align: center;width: 75px\">Precursor<\/th><th style=\"text-align: center;width: 75px\">Product 1<\/th><th style=\"text-align: center;width: 75px\">Product 2<\/th><\/tr><\/thead>\n<tbody><tr><td class=\"num\">1.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/28646-40-4\/11-OH-\u03948-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03948-THC<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">2.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for 11-OH-\u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/34675-49-5\/11-OH-\u03949-THC\" target=\"_blank\" rel=\"noopener\">11-OH-\u03949-THC<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">331.0<\/td><td class=\"oth\">313.0<\/td><td class=\"oth\">201.1<\/td><\/tr>\n<tr><td class=\"num\">3.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/39690-06-7\/\u03948-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03948-THC-COOH<\/a><\/td><td class=\"oth\">500<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">4.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC-COOH\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/56354-06-4\/\u03949-THC-COOH\" target=\"_blank\" rel=\"noopener\">\u03949-THC-COOH<\/a><\/td><td class=\"oth\">500<\/td><td class=\"oth\">345.1<\/td><td class=\"oth\">327.0<\/td><td class=\"oth\">299.2<\/td><\/tr>\n<tr><td class=\"num\">5.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03948-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/5957-75-5\/\u03948-THC\" target=\"_blank\" rel=\"noopener\">\u03948-THC<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<tr><td class=\"num\">6.<\/td><td class=\"cmpd\"><a class=\"cmpd_link\" title=\"View compound information for \u03949-THC\" href=\"https:\/\/ez.restek.com\/compound\/view\/en\/1972-08-3\/\u03949-THC\" target=\"_blank\" rel=\"noopener\">\u03949-THC<\/a><\/td><td class=\"oth\">100<\/td><td class=\"oth\">315.0<\/td><td class=\"oth\">193.0<\/td><td class=\"oth\">123.2<\/td><\/tr>\n<\/tbody><\/table><\/div><div class=\"chromatogram-conditions\"><h4>Conditions<\/h4><div class=\"conditions-container container-fluid\"><div class=\"row\"><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Column<\/th><td>See notes.<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Dimensions:<\/th><td>100 mm x 3 mm ID<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Particle Size:<\/th><td>2.7 \u00b5m<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Pore Size:<\/th><td>90 \u00c5<\/td><\/tr><tr><td><\/td><tr><th class=\"sub conditions_header\" scope=\"row\">Temp.:<\/th><td>40 \u00b0C<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Standard\/Sample<\/th><td><\/td><\/tr><tr><td><\/td><td>\u03948-Tetrahydrocannabinol (\u03948-THC) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34090\" rel=\"noopener\">cat.# 34090<\/a>)<\/td><\/tr><tr><td><\/td><td>\u03949-Tetrahydrocannabinol (\u03949-THC) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34067\" rel=\"noopener\">cat.# 34067<\/a>)<\/td><\/tr><tr><td><\/td><td>(\u00b1)11-nor-9-carboxy-\u0394-9-THC (\u03949-THC-COOH) (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/34068\" rel=\"noopener\">cat.# 34068<\/a>)<\/td><\/tr><tr><td><\/td><td>Other compounds obtained separately. <\/td><\/tr>\n<tr><th class=\"sub conditions_header\" scope=\"row\">Diluent:<\/th><td>40:60 Water:methanol, both with 0.1% formic acid (v\/v)<\/td><\/tr><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Inj. Vol.:<\/th><td>5 \u00b5L <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Mobile Phase<\/th><td><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">A:<\/th><td>Water, 0.1% formic acid <\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">B:<\/th><td>Methanol, 0.1% formic acid <\/td><\/tr><tr><td><\/td><td><table class=\"cgram_ramp\"><thead><tr><th>Time (min)<\/th><th>Flow (mL\/min)<\/th><th>%A<\/th><th>%B<\/th><\/tr><\/thead><tbody><tr><td>0.00<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.50<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.60<\/td><td>0.8<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.00<\/td><td>0.8<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.10<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.00<\/td><td>0.8<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.10<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>16.00<\/td><td>0.8<\/td><td>36<\/td><td>64<\/td><\/tr><\/tbody><\/table><\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Max Pressure:<\/th><td>390 bar<\/td><\/tr><\/table><table class=\"conditions col-lg-6 col-12\"><tr><th class=\"conditions_header\" scope=\"row\">Detector<\/th><td>Shimadzu 8045 MS\/MS<\/td><\/tr><tr><th class=\"sub conditions_header\" scope=\"row\">Ion Mode:<\/th><td>ESI+ <\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Instrument<\/th><td>Shimadzu Nexera X2<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Sample Preparation<\/th><td>Five hundred microliters of whole blood was transferred to a 12 mL glass test tube. Fifty microliters of internal standard and 50 \u00b5L of control material were transferred to the test tube and vortexed. Five hundred microliters of HPLC grade water was added to each sample and vortexed. One hundred microliters of 10% acetic acid was added to each sample and vortexed. Two and a half milliliters of 80:20 hexanes:ethyl acetate was added to each sample and vortexed until visibly combined. Samples were centrifuged at 2800 rpm for 15 minutes. The top layer was transferred to a new glass test tube and dried down under nitrogen. Samples were reconstituted with 100 \u00b5L of 40:60 methanol:water, both containing 0.1% formic acid, and vortexed. Samples were transferred to 2 mL screw-thread vials (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21143\" rel=\"noopener\">cat.# 21143<\/a>) with glass inserts (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/21776\" rel=\"noopener\">cat.# 21776<\/a>) and capped with short-cap, screw-vial closures (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/24498\" rel=\"noopener\">cat.# 24498<\/a>).<\/td><\/tr><tr class=\"cgram_header_row\"><th class=\"conditions_header\" scope=\"row\">Notes<\/th><td>The column was stored in 100% acetonitrile when not in use. <br \/><br \/>Columns are:<br \/><br \/>Raptor Inert FluoroPhenyl (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9319A1E-T\" rel=\"noopener\">cat.# 9319A1E-T<\/a>)<br \/>Raptor FluoroPhenyl (<a class=\"ga-cgram-prod-link\" target=\"_blank\" href=\"https:\/\/www.restek.com\/p\/9319A1E\" rel=\"noopener\">cat.# 9319A1E<\/a>)<\/td><\/tr><\/table><\/div><\/div><\/div><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>34090<\/li><li>34067<\/li><li>34068<\/li><li>9319A1E<\/li><li>21143<\/li><li>21776<\/li><li>24498<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>cannabinoids<\/li><li>fluorophenyl<\/li><li>inert<\/li><li>isomers<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_cf0829.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u5b9f\u9a13\u7d50\u679c\u304b\u3089\u3001\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u30016\u7a2e\u985e\u3059\u3079\u3066\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306b\u304a\u3044\u3066\u30d4\u30fc\u30af\u9ad8\u3055\u304a\u3088\u3073\u9762\u7a4d\u306e\u5897\u52a0\u304c\u3042\u3063\u305f\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u89aa\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u306f\u30d4\u30fc\u30af\u9ad8\u3055\u30fb\u9762\u7a4d\u306e\u5897\u52a0\u306f2\uff5e7%\u3068\u308f\u305a\u304b\u3067\u3057\u305f\u304c\u3001\u30d2\u30c9\u30ed\u30ad\u30b7\u4ee3\u8b1d\u7269\u3067\u306f17\uff5e27%\u3001\u30ab\u30eb\u30dc\u30ad\u30b7\u4ee3\u8b1d\u7269\u3067\u306f\u3055\u3089\u306b\u5927\u304d\u304f31\uff5e39%\u3068\u3001\u7279\u306b\u4ee3\u8b1d\u7269\u3067\u9855\u8457\u306a\u5411\u4e0a\u304c\u898b\u3089\u308c\u307e\u3057\u305f\u3002\u3068\u308a\u308f\u3051\u30ab\u30eb\u30dc\u30ad\u30b7\u5316\u5408\u7269\u3067\u691c\u51fa\u611f\u5ea6\u304c\u5927\u304d\u304f\u5411\u4e0a\u3057\u305f\u306e\u306f\u3001\u30ab\u30eb\u30dc\u30f3\u9178\u5b98\u80fd\u57fa\u304c\u91d1\u5c5e\u8868\u9762\u3068\u975e\u7279\u7570\u7684\u306b\u7d50\u5408\u3057\u3084\u3059\u3044\u3053\u3068\u304c\u4e3b\u306a\u8981\u56e0\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u4e00\u65b9\u3001\u30d2\u30c9\u30ed\u30ad\u30b7\u5316\u5408\u7269\u3084\u89aa\u5316\u5408\u7269\u306f\u3088\u308a\u4e2d\u6027\u3067\u3042\u308b\u305f\u3081\u3001\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u3053\u3068\u306b\u3088\u308b\u5f71\u97ff\u306f\u6bd4\u8f03\u7684\u9650\u5b9a\u7684\u3067\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u7d50\u679c\u304b\u3089\u3001\u30a4\u30ca\u30fc\u30c8\u30ab\u30e9\u30e0\u306e\u5c0e\u5165\u306f\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u306e\u691c\u51fa\u611f\u5ea6\u5411\u4e0a\u306b\u6709\u52b9\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u5506\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5168\u8840\u4e2d\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u5206\u6790\u306b\u304a\u3044\u3066\u4f4e\u3044\u691c\u51fa\u9650\u754c\u306e\u9054\u6210\u306b\u8ab2\u984c\u304c\u3042\u308b\u5834\u5408\u3001\u30a4\u30ca\u30fc\u30c8LC\u30ab\u30e9\u30e0\u306e\u5c0e\u5165\u306f\u6709\u52b9\u306a\u9078\u629e\u80a2\u3068\u306a\u308a\u5f97\u307e\u3059\u3002\u751f\u4f53\u6db2\u4e2d\u306eTHC\u7570\u6027\u4f53\u306e\u5206\u6790\u306b\u95a2\u5fc3\u304c\u3042\u308b\u65b9\u306f\u3001\u3055\u3089\u306a\u308b\u60c5\u5831\u3092\u300c<a href=\"https:\/\/discover.restek.com\/ja\/application-notes-ja\/cfan4420-ja\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/CFAN4420-JA\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine-japan\" rel=\"noreferrer noopener\">\u5168\u8840\u30fb\u5c3f\u4e2dTHC\u7570\u6027\u4f53\u304a\u3088\u3073\u4ee3\u8b1d\u7269\u306e\u9ad8\u611f\u5ea6LC-MS\/MS\u30e1\u30bd\u30c3\u30c9<\/a>\u300d\u304b\u3089\u3001\u305c\u3072\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E-T\">                                \u30ab\u30bf\u30ed\u30b0No. 9319A1E-T                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor Inert FluoroPhenyl, 2.7 \u00b5m, 100 x 3.0 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E-T\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">                                \u30ab\u30bf\u30ed\u30b0No. 34090                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">delta 8-Tetrahydrocannabinol (Delta 8-THC) Standard, 1000 \u00b5g\/mL in P&amp;T Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34090\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">                                \u30ab\u30bf\u30ed\u30b0No. 34067                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">\u30c7\u30eb\u30bf9-\u30c6\u30c8\u30e9\u30d2\u30c9\u30ed\u30ab\u30f3\u30ca\u30d3\u30ce\u30fc\u30eb (Delta 9-THC) \u6a19\u6e96\u6db2 1000 \u00b5g\/m, 1 mL\/ampul \uff5c\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u5206\u6790<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34067\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">                                \u30ab\u30bf\u30ed\u30b0No. 34068                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">(\u00b1)11-nor-9-carboxy-Delta-9-THC Standard, 100 \u00b5g\/mL, methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/34068\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">                                \u30ab\u30bf\u30ed\u30b0No. 21143                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short-Cap Vial with Grad Marking Spot, 9-425 Screw-Thread, 2.0 mL, 9 mm, 12 x 32 (vial only), Amber, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21143\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">                                \u30ab\u30bf\u30ed\u30b0No. 21776                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Vial Inserts, Glass, Big Mouth w\/Bottom Spring, 250 \u00b5L, 100-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21776\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">                                \u30ab\u30bf\u30ed\u30b0No. 24498                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Short Screw Cap, Polypropylene, Screw-Thread, PTFE\/Silicone\/PTFE Septa, Blue, Preassembled, 2.0 mL, 9 mm, 1000-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/24498\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u5168\u8840\u4e2d\u306e\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9LC-MS\/MS\u5206\u6790\u306b\u304a\u3051\u308b\u691c\u51fa\u9650\u754c\u306e\u8ab2\u984c\u3092\u89e3\u6c7a\u3059\u308b\u305f\u3081\u3001\u30a4\u30ca\u30fc\u30c8LC\u30ab\u30e9\u30e0\u306e\u5c0e\u5165\u52b9\u679c\u3092\u8a73\u3057\u304f\u89e3\u8aac\u3002\u30d4\u30fc\u30af\u5f62\u72b6\u3084\u691c\u51fa\u611f\u5ea6\u306e\u5411\u4e0a\u3001\u7279\u306b\u4ee3\u8b1d\u7269\u5206\u6790\u3067\u306e\u30e1\u30ea\u30c3\u30c8\u3092\u5b9f\u9a13\u30c7\u30fc\u30bf\u3068\u3068\u3082\u306b\u7d39\u4ecb\u3057\u307e\u3059\u3002\u751f\u4f53\u8a66\u6599\u4e2d\u306eTHC\u7570\u6027\u4f53\u5206\u6790\u306b\u3082\u5f79\u7acb\u3064\u6700\u65b0\u60c5\u5831\u3067\u3059\u3002<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[2263,2282],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2365,2343],"ppma_author":[432],"class_list":["post-48560","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","industries-application-cannabis-ja","industries-application-medical-recreational-cannabis-ja","resource-technique-ms-ms-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"industries-application":[{"value":2263,"label":"\u30ab\u30f3\u30ca\u30d3\u30b9"},{"value":2282,"label":"\u533b\u7642\u7528\uff5c\u55dc\u597d\u7528 \u30ab\u30f3\u30ca\u30d3\u30b9"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/ja\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48560","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48560"}],"version-history":[{"count":6,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48560\/revisions"}],"predecessor-version":[{"id":83690,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48560\/revisions\/83690"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48560"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48560"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48560"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48560"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48560"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48560"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48560"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48560"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48560"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}