{"id":48561,"date":"2025-06-17T00:00:00","date_gmt":"2025-06-17T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/semi-synthetic-cannabinoids-more-isomers-japan\/"},"modified":"2026-01-21T18:52:23","modified_gmt":"2026-01-21T18:52:23","slug":"semi-synthetic-cannabinoids-more-isomers-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4789-ja\/semi-synthetic-cannabinoids-more-isomers-japan","title":{"rendered":"\u534a\u5408\u6210\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u5206\u6790\u306e\u6700\u524d\u7dda\uff1aTHC\u7570\u6027\u4f53\u30fb\u4ee3\u8b1d\u7269\u306e\u9ad8\u7cbe\u5ea6\u5206\u96e2\u6cd5"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">LC-MS\/MS\u3092\u7528\u3044\u305f\u7570\u6027\u4f53\u5206\u96e2<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8fd1\u5e74\u3001\u03948-THC\u306f\u03949-THC\u306e\u300c\u5408\u6cd5\u7684\u300d\u306a\u4ee3\u66ff\u54c1\u3068\u3057\u3066\u6ce8\u76ee\u3092\u96c6\u3081\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u6d41\u901a\u62e1\u5927\u306b\u4f34\u3044\u3001\u6bd2\u7269\u691c\u67fb\u30e9\u30dc\u306b\u304a\u3044\u3066\u03948-THC\u3068\u03949-THC\u306e\u7570\u6027\u4f53\u3092\u6b63\u78ba\u306b\u8b58\u5225\u3059\u308b\u5fc5\u8981\u6027\u3082\u9ad8\u307e\u3063\u3066\u304d\u3066\u3044\u307e\u3059\u3002\u7279\u306bLC-MS\/MS\u3092\u7528\u3044\u308b\u30e9\u30dc\u3067\u306f\u3001\u3053\u308c\u3089\u306e\u7570\u6027\u4f53\u304a\u3088\u3073\u305d\u306e\u4ee3\u8b1d\u7269\u3092\u5b8c\u5168\u306b\u5206\u96e2\u3057\u3001\u6b63\u78ba\u306b\u5b9a\u91cf\u3059\u308b\u3053\u3068\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u5f93\u6765\u3001\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u5206\u6790\u306b\u306fBiphenyl\u3084C18\u306a\u3069\u306eHPLC\u56fa\u5b9a\u76f8\u304c\u591a\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u304c\u3001\u3053\u308c\u3089\u306e\u30ab\u30e9\u30e0\u3067\u306f\u03948-THC\u3068\u03949-THC\u306e\u7570\u6027\u4f53\u5206\u96e2\u306b\u5341\u5206\u306a\u9078\u629e\u6027\u304c\u5f97\u3089\u308c\u305a\u3001\u30d4\u30fc\u30af\u306e\u91cd\u306a\u308a\u3084\u5b9a\u91cf\u8aa4\u5dee\u306e\u30ea\u30b9\u30af\u304c\u6b8b\u3063\u3066\u3044\u307e\u3057\u305f\u3002\u3053\u3046\u3057\u305f\u8ab2\u984c\u306b\u5bfe\u3057\u3001Raptor FluoroPhenyl\u30ab\u30e9\u30e0\u304c\u65b0\u305f\u306a\u9078\u629e\u80a2\u3068\u3057\u3066\u767b\u5834\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30ab\u30e9\u30e0\u306f\u72ec\u81ea\u306e\u9078\u629e\u6027\u3092\u6301\u3061\u3001\u03948-THC\u3001\u03949-THC\u3001\u304a\u3088\u3073\u305d\u306e\u4ee3\u8b1d\u7269\uff08\u30ab\u30eb\u30dc\u30ad\u30b7\u4f53\u3084\u30d2\u30c9\u30ed\u30ad\u30b7\u4f53\uff09\u3092\u3001\u5c3f\u3084\u5168\u8840\u3068\u3044\u3063\u305f\u8907\u96d1\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u3067\u3082\u5b8c\u5168\u306b\u5206\u96e2\u3067\u304d\u307e\u3059\u3002\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8\u300c<a href=\"https:\/\/discover.restek.com\/ja\/application-notes-ja\/cfan4420-ja\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/CFAN4420-JA\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine-japan\" rel=\"noreferrer noopener\">\u5168\u8840\u30fb\u5c3f\u4e2dTHC\u7570\u6027\u4f53\u304a\u3088\u3073\u4ee3\u8b1d\u7269\u306e\u9ad8\u611f\u5ea6LC-MS\/MS\u30e1\u30bd\u30c3\u30c9<\/a>\u300d\u3067\u306f\u3001\u3053\u306eRaptor FluoroPhenyl\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5168\u8840\u304a\u3088\u3073\u5c3f\u4e2d\u306eTHC\u7570\u6027\u4f53\u30fb\u4ee3\u8b1d\u7269\u306e\u5b8c\u5168\u5206\u96e2\u3068\u5b9a\u91cf\u3092\u53ef\u80fd\u306b\u3059\u308bLC-MS\/MS\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u8a73\u7d30\u306b\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u306e\u3067\u305c\u3072\u3053\u3061\u3089\u3082\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002\u3000<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u534a\u5408\u6210\u30ab\u30f3\u30d3\u30ca\u30ce\u30a4\u30c9\u306e\u51fa\u73fe<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3055\u3066\u3001\u6700\u8fd1\u554f\u984c\u306a\u306e\u306f\u3001\u5e02\u5834\u306b\u767b\u5834\u3057\u3066\u304d\u305f\u591a\u304f\u306e\u65b0\u898f\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u3001\u3064\u307e\u308a\u300c\u534a\u5408\u6210\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u300d\u3067\u3059\u3002\u306a\u305c\u300c\u534a\u5408\u6210\u300d\u306a\u306e\u3067\u3057\u3087\u3046\u304b\u3002\u305d\u308c\u306f\u3001\u5927\u9ebb\u3084\u30d8\u30f3\u30d7\u306b\u672c\u6765\u3054\u304f\u5fae\u91cf\u3057\u304b\u542b\u307e\u308c\u306a\u3044\u6210\u5206\u3092\u5408\u6210\u3057\u300c\u5929\u7136\u7531\u6765\u300d\u3068\u3057\u305f\u308a\u3001\u65e2\u5b58\u306e\u5316\u5b66\u69cb\u9020\u3092\u308f\u305a\u304b\u306b\u6539\u5909\u3057\u3066\u5168\u304f\u65b0\u3057\u3044\u7269\u8cea\u3092\u4f5c\u308a\u51fa\u3057\u305f\u308a\u3057\u3066\u3044\u308b\u304b\u3089\u3067\u3059\u3002\u305d\u3053\u3067\u30012025\u5e74\u306e\u521d\u3081\u3001\u6cd5\u79d1\u5b66\u7814\u7a76\u6559\u80b2\u30bb\u30f3\u30bf\u30fc\uff08CFSRE\uff09\u306f\u3001<a href=\"https:\/\/www.cfsre.org\/nps-discovery\/scope-recommendations\" target=\"_blank\" rel=\"noreferrer noopener\">\u56db\u534a\u671f\u3054\u3068\u306b\u767a\u8868\u3059\u308b\u30b9\u30b3\u30fc\u30d7\u52e7\u544a\uff08\u82f1\u8a9e\u306e\u307f\uff09<\/a>\u306b\u300c\u534a\u5408\u6210\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u300d\u306e\u30ab\u30c6\u30b4\u30ea\u30fc\u3092\u65b0\u305f\u306b\u8ffd\u52a0\u3057\u307e\u3057\u305f\u3002\u3053\u3046\u3057\u305f\u5316\u5408\u7269\u306e\u5b58\u5728\u611f\u304c\u9ad8\u307e\u3063\u3066\u304d\u3066\u3044\u308b\u305f\u3081\u3001\u6bd2\u7269\u691c\u67fb\u30e9\u30dc\u306f\u3053\u308c\u3089\u306e\u65b0\u3057\u3044\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u3092\u65e2\u5b58\u306e\u03948\/\u03949-THC\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u3067\u691c\u51fa\u3001\u5b9a\u91cf\u3059\u308b\u5fc5\u8981\u6027\u3092\u611f\u3058\u3066\u3044\u308b\u3053\u3068\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3057\u304b\u3057\u3001\u65e2\u5b58\u30e1\u30bd\u30c3\u30c9\u306b\u65b0\u3057\u3044\u5316\u5408\u7269\u3092\u8ffd\u52a0\u3059\u308b\u3053\u3068\u306f\u3001\u7279\u306b\u7570\u6027\u4f53\u304c\u542b\u307e\u308c\u308b\u5834\u5408\u3001\u6c7a\u3057\u3066\u7c21\u5358\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u65b0\u305f\u306a\u5316\u5408\u7269\u3092\u6b63\u78ba\u306b\u691c\u51fa\u30fb\u5b9a\u91cf\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30e1\u30bd\u30c3\u30c9\u5168\u4f53\u306e\u6761\u4ef6\u3092\u898b\u76f4\u3059\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u4e0a\u3001\u4ed6\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u5f93\u6765\u901a\u308a\u9069\u5207\u306b\u5206\u96e2\u30fb\u691c\u51fa\u3067\u304d\u308b\u3053\u3068\u3082\u78ba\u8a8d\u3057\u306a\u3051\u308c\u3070\u306a\u308a\u307e\u305b\u3093\u3002\u5834\u5408\u306b\u3088\u3063\u3066\u306f\u3001\u65b0\u3057\u3044\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u8ffd\u52a0\u3055\u308c\u305f\u3053\u3068\u306b\u3088\u308a\u3001\u30e9\u30f3\u30bf\u30a4\u30e0\u304c\u9577\u304f\u306a\u308b\u3053\u3068\u306e\u8a31\u5bb9\u3084\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306e\u5909\u66f4\u304c\u5fc5\u8981\u306b\u306a\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u306b\u8a18\u8f09\u3057\u305f\u3088\u3046\u306b\u3001\u03948-THC\u3001\u03949-THC\u3001\u304a\u3088\u3073\u305d\u308c\u3089\u306e\u30d2\u30c9\u30ed\u30ad\u30b7\u4ee3\u8b1d\u7269\u3068\u30ab\u30eb\u30dc\u30ad\u30b7\u4ee3\u8b1d\u7269\u306e\u5206\u6790\u7528\u306b\u958b\u767a\u3055\u308c\u305f\u65e2\u5b58\u30e1\u30bd\u30c3\u30c9\u306b\u3001\u65b0\u305f\u306a\u5316\u5408\u7269\u3068\u3057\u30666\u7a2e\u985e\u306e\u534a\u5408\u6210\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u3092\u8ffd\u52a0\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u30ce\u30fc\u30c8\u300c<a href=\"https:\/\/discover.restek.com\/ja\/application-notes-ja\/cfan4420-ja\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/CFAN4420-JA\/lc-ms-ms-analysis-of-thc-isomers-and-metabolites-in-whole-blood-and-urine-japan\" rel=\"noreferrer noopener\">\u5168\u8840\u30fb\u5c3f\u4e2dTHC\u7570\u6027\u4f53\u304a\u3088\u3073\u4ee3\u8b1d\u7269\u306e\u9ad8\u611f\u5ea6LC-MS\/MS\u30e1\u30bd\u30c3\u30c9<\/a>\u300d\u306b\u3001\u5168\u8840\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u3068\u3057\u3066\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eca\u56de\u8ffd\u52a0\u3057\u305f6\u7a2e\u985e\u306e\u534a\u5408\u6210\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\uff089(R)-HHC\u30019(S)-HHC\u3001\u039410-THC\u3001THC-O-Acetate\u3001THCP\u3001CBDP\uff09\u306f\u3001CFSRE\u306b\u3088\u3063\u3066\u73fe\u5728\u306e\u63a8\u5968\u7bc4\u56f2\u3068\u3057\u3066\u7279\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u30029(R)-HHC\u30689(S)-HHC\u306f\u30a8\u30d4\u30de\u30fc\u306e\u95a2\u4fc2\u306b\u3042\u308a\u3001THCP\u3068CBDP\u306f\u305d\u308c\u305e\u308c\u7570\u6027\u4f53\u3067\u3059\u3002\u307e\u305f\u3001\u039410-THC\u306f\u03948-THC\u3068\u03949-THC\u306e\u5225\u306e\u7570\u6027\u4f53\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3068\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306e\u6bd4\u8f03<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u5bfe\u8c61\u6210\u5206100 ng\/mL\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790\u3092\u3001\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3067\u5b9f\u884c\u3057\u307e\u3057\u305f\u3002\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3068\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Figure 1. \u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3068\u65b0\u3057\u3044\u534a\u5408\u6210\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u3092\u542b\u3080\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td colspan=\"3\">Raptor FluoroPhenyl 100 x 3 mm, 2.7 \u00b5m (cat.# 9319A1E)<\/td><\/tr><tr><td><strong>\u79fb\u52d5\u76f8A<\/strong><\/td><td colspan=\"3\">\u6c34,\u30010.1% \u30ae\u9178<\/td><\/tr><tr><td><strong>\u79fb\u52d5\u76f8B<\/strong><\/td><td colspan=\"3\">\u30e1\u30bf\u30ce\u30fc\u30eb\u30010.1% \u30ae\u9178<\/td><\/tr><tr><td><strong>\u30ab\u30e9\u30e0\u6e29\u5ea6<\/strong><\/td><td colspan=\"3\">40\u00b0C<\/td><\/tr><tr><td><strong>\u6d41\u901f<\/strong><\/td><td colspan=\"3\">0.8 mL\/min<\/td><\/tr><tr><td rowspan=\"9\"><strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8<\/strong><\/td><td>\u6642\u9593 (min)<\/td><td>%A<\/td><td>%B<\/td><\/tr><tr><td>0.00<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.50<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>6.60<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.00<\/td><td>32<\/td><td>68<\/td><\/tr><tr><td>13.10<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.00<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.10<\/td><td>36<\/td><td>64<\/td><\/tr><tr><td>16.00<\/td><td>36<\/td><td>64<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-semi-synthetic-cannabinoids-1.jpg\" alt=\"\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3067\u5206\u6790\u3092\u884c\u3063\u305f\u3068\u3053\u308d\u3001\u3059\u3079\u3066\u306e\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u306f\u826f\u597d\u306b\u5206\u96e2\u3055\u308c\u307e\u3057\u305f\u3002\u3057\u304b\u3057\u3001THCP\u3068THC-O-Acetate\u306f\u758e\u6c34\u6027\u304c\u975e\u5e38\u306b\u9ad8\u3044\u305f\u3081\u4fdd\u6301\u6642\u9593\u304c\u9577\u304f\u3001\u79fb\u52d5\u76f8B\u3092100%\u307e\u3067\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3057\u305f\u5f8c\u3001\u7d0414\u5206\u306b\u306a\u3063\u3066\u3088\u3046\u3084\u304f\u6eb6\u51fa\u3057\u307e\u3057\u305f\u3002\u4e00\u822c\u7684\u306b\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u758e\u6c34\u6027\u6210\u5206\u3084\u975e\u5e38\u306b\u89aa\u6cb9\u6027\u306e\u9ad8\u3044\u5316\u5408\u7269\u3092\u30ab\u30e9\u30e0\u304b\u3089\u5b8c\u5168\u306b\u6eb6\u51fa\u3055\u305b\u308b\u3001\u307e\u305f\u306f\u6d17\u3044\u51fa\u3059\u305f\u3081\u306b\u3001\u6709\u6a5f\u6eb6\u5a92\u6fc3\u5ea6\u3092100%\u306b\u3057\u305f\u72b6\u614b\u3067\u4e00\u5b9a\u6642\u9593\u4fdd\u6301\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u30b9\u30c6\u30c3\u30d7\u306f\u3001\u6b21\u306e\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u6642\u306e\u30ad\u30e3\u30ea\u30fc\u30aa\u30fc\u30d0\u30fc\u3092\u4f4e\u6e1b\u3059\u308b\u52b9\u679c\u3082\u3042\u308a\u307e\u3059\u3002\u4e00\u65b9\u3067\u3001\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u7531\u6765\u306e\u758e\u6c34\u6027\u6210\u5206\u306f\u3053\u306e\u9818\u57df\u3067\u5171\u6eb6\u51fa\u3057\u3084\u3059\u304f\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u30d4\u30fc\u30af\u306b\u5e72\u6e09\u3092\u53ca\u307c\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u5206\u6790\u5bfe\u8c61\u6210\u5206\u304c\u3053\u306e\u9818\u57df\u3067\u6eb6\u51fa\u3059\u308b\u306e\u306f\u671b\u307e\u3057\u3044\u3053\u3068\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u305d\u3053\u3067\u3001\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u306e\u5206\u96e2\u3092\u7dad\u6301\u3057\u3064\u3064\u3001\u3053\u308c\u3089\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306e\u691c\u51fa\u6027\u80fd\u3092\u5411\u4e0a\u3055\u305b\u308b\u3088\u3046\u3001\u30e1\u30bd\u30c3\u30c9\u30d1\u30e9\u30e1\u30fc\u30bf\u3092\u6700\u9069\u5316\u3057\u307e\u3057\u305f\u3002\u8abf\u6574\u5f8c\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3068\u305d\u306e\u6761\u4ef6\u4e0b\u3067\u5f97\u3089\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\">Figure 2. \u8abf\u6574\u5f8c\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u304a\u3088\u3073\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\" style=\"border-width:1px\"><tbody><tr><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td colspan=\"3\">Raptor FluoroPhenyl 100 x 3 mm, 2.7 \u00b5m (cat.# 9319A1E)<\/td><\/tr><tr><td><strong>\u79fb\u52d5\u76f8A<\/strong><\/td><td colspan=\"3\">\u6c34,\u30010.1% \u30ae\u9178<\/td><\/tr><tr><td><strong>\u79fb\u52d5\u76f8B<\/strong><\/td><td colspan=\"3\">\u30e1\u30bf\u30ce\u30fc\u30eb\u30010.1% \u30ae\u9178<\/td><\/tr><tr><td><strong>\u30ab\u30e9\u30e0\u6e29\u5ea6<\/strong><\/td><td colspan=\"3\">30\u00b0C<\/td><\/tr><tr><td><strong>\u6d41\u901f<\/strong><\/td><td colspan=\"3\">0.8 mL\/min<\/td><\/tr><tr><td rowspan=\"10\"><strong>\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8<\/strong><\/td><td>\u6642\u9593 (min)<\/td><td>%A<\/td><td>%B<\/td><\/tr><tr><td>0.00<\/td><td>34<\/td><td>66<\/td><\/tr><tr><td>5.50<\/td><td>34<\/td><td>66<\/td><\/tr><tr><td>5.60<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>10.50<\/td><td>30<\/td><td>70<\/td><\/tr><tr><td>11.00<\/td><td>15<\/td><td>85<\/td><\/tr><tr><td>13.00<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.00<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>14.10<\/td><td>34<\/td><td>66<\/td><\/tr><tr><td>16.00<\/td><td>34<\/td><td>66<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-semi-synthetic-cannabinoids-2.jpg\" alt=\"\" title=\"-\"><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u7d50\u8ad6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u8abf\u6574\u5f8c\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3067\u5206\u6790\u3092\u884c\u3063\u305f\u7d50\u679c\u3001\u79fb\u52d5\u76f8B\u3092100%\u306b\u4fdd\u6301\u3059\u308b\u6642\u9593\uff0813\uff5e14\u5206\uff09\u524d\u306b\u3001\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3067\u306e\u5206\u6790\u3088\u308a\u3082\u65e9\u3044\u4fdd\u6301\u6642\u9593\u3067THCP\u304a\u3088\u3073THC-O-Acetate\u306f\u6eb6\u51fa\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001\u30ab\u30e9\u30e0\u6e29\u5ea6\u309240\u2103\u304b\u308930\u2103\u306b\u4e0b\u3052\u3066\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u9593\u306e\u5206\u96e2\u3092\u5411\u4e0a\u3055\u305b\u3001\u3055\u3089\u306b\u6eb6\u51fa\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3092\u6700\u9069\u5316\u3057\u305f\u3053\u3068\u306b\u3088\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u30016\u7a2e\u985e\u306e\u534a\u5408\u6210\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u3092\u3001\u30e9\u30f3\u30bf\u30a4\u30e0\u306f\u305d\u306e\u307e\u307e\u306b\u3001\u03948\/9-THC\u304a\u3088\u3073\u305d\u306e\u4ee3\u8b1d\u7269\u306e\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306b\u7121\u7406\u306a\u304f\u7d44\u307f\u8fbc\u3080\u3053\u3068\u304c\u51fa\u6765\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">                                \u30ab\u30bf\u30ed\u30b0No. 9319A1E                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Raptor FluoroPhenyl, 2.7 \u00b5m, 100 x 3.0 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9319A1E\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>&Delta;8-THC\u3084&Delta;9-THC\u306a\u3069\u306e\u7570\u6027\u4f53\u30fb\u4ee3\u8b1d\u7269\u306b\u52a0\u3048\u30016\u7a2e\u985e\u306e\u534a\u5408\u6210\u30ab\u30f3\u30ca\u30d3\u30ce\u30a4\u30c9\u3092\u9ad8\u611f\u5ea6\u304b\u3064\u9ad8\u7cbe\u5ea6\u306b\u5206\u96e2\u30fb\u5b9a\u91cf\u3067\u304d\u308b\u6700\u65b0LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u3092\u89e3\u8aac\u3002Raptor FluoroPhenyl\u30ab\u30e9\u30e0\u306b\u3088\u308b\u5c3f\u30fb\u5168\u8840\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u4e2d\u306e\u5206\u6790\u4e8b\u4f8b\u3084\u3001\u30e1\u30bd\u30c3\u30c9\u6700\u9069\u5316\u306e\u30dd\u30a4\u30f3\u30c8\u3082\u8a73\u3057\u304f\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[2263,2282],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2343,2345],"ppma_author":[432],"class_list":["post-48561","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","industries-application-cannabis-ja","industries-application-medical-recreational-cannabis-ja","resource-technique-liquid-chromatography-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"industries-application":[{"value":2263,"label":"\u30ab\u30f3\u30ca\u30d3\u30b9"},{"value":2282,"label":"\u533b\u7642\u7528\uff5c\u55dc\u597d\u7528 \u30ab\u30f3\u30ca\u30d3\u30b9"}],"resource-technique":[{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/ja\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48561","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48561"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48561\/revisions"}],"predecessor-version":[{"id":83693,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48561\/revisions\/83693"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48561"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48561"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48561"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48561"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48561"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48561"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48561"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48561"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48561"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}