{"id":48563,"date":"2016-10-31T14:30:00","date_gmt":"2016-10-31T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/japanese-a-brief-introduction-to-diatosorb-w-2\/"},"modified":"2025-11-25T17:58:28","modified_gmt":"2025-11-25T17:58:28","slug":"japanese-a-brief-introduction-to-diatosorb-w-2","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4566-ja\/japanese-a-brief-introduction-to-diatosorb-w-2","title":{"rendered":"\u73ea\u85fb\u571f\u62c5\u4f53DiatoSorb-W\u306e\u3054\u7d39\u4ecb"},"content":{"rendered":"\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-a-brief-introduction-to-diatosorb-w-01.jpg\" alt=\"diatosorb\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">DiatoSorb-W\u306f\u73ea\u85fb\u571f\u62c5\u4f53\u3067\u3059\u3002Restek\u306fChromosorb-W\u88fd\u54c1\u3084Chromosorb-W\u5145\u586b\u5264\u306e\u4ee3\u66ff\u54c1\u3068\u3057\u3066\u3001DiatoSorb-W\u3092\u4f7f\u7528\u3057\u305f\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3068\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3055\u308c\u305f\u5145\u586b\u5264(\u6db2\u76f8\u306e\uff05\u306f\u9078\u629e\u53ef\u80fd)\u306e\u8ca9\u58f2\u3092\u958b\u59cb\u3057\u307e\u3059\u3002\u201dW\u201d\u306f\u201dWhite(\u767d)\u201d\u306e\u7565\u3067\u3001\u672a\u51e6\u7406\u3067\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u3055\u308c\u3066\u3044\u306a\u3044\u72b6\u614b\u306e\u8272\u3092\u8868\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">USP S1A\u306b\u6e96\u62e0\u3057\u305f\u30ab\u30e9\u30e0\u3001\u3082\u3057\u304f\u306fChromosorb-W\/AW(\u9178\u6d17\u6d44)\u3092\u4f7f\u7528\u3057\u3066\u304a\u308a\u3001DMDCS\u3082\u3057\u304f\u306fDMCS\u306b\u3088\u308b\u51e6\u7406\u30fb\u4e0d\u6d3b\u6027\u5316\u3092\u3057\u3066\u3044\u306a\u3044\u5834\u5408\u306fDitoSorb-W-WA\u3092\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001USP S1NS\u306b\u6e96\u62e0\u3057\u305f\u30ab\u30e9\u30e0\u3082\u3057\u304f\u306fChromosorb-W\/NAW(\u9178\u6d17\u6d44\u306a\u3057)\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u306f\u3001DiatoSorb-W\/NAW\u3092\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u3068\u3081:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>USP S1A<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DiatoSorb-W\/AW = Chromosorb-W\/AW<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DiatoSorb-WHP = Chromosorb-W\/AW-DMDCS<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>USP S1NS<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DiatoSorb-W\/NAW = Chromosorb-W\/NAW<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7565\u8a9e:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">W = white<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">AW = acid washed<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">NAW = non-acid washed<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">HP = high performance<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">DMDCS = dimethyldichlorosilane (\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u8a66\u85ac). &nbsp;DMCS (dimethylchlorosilane)\u3068\u8868\u8a18\u3055\u308c\u308b\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Silcoport-W\u3092\u7528\u3044\u305f\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u306f\u3001\u540d\u524d\u306e\u5909\u66f4\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001\u5145\u586b\u5264\u306fChromosorb-W\u306e\u4ee3\u308f\u308a\u306bDiatoSorb-W\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002Silcoport-W\u5145\u586b\u5264\u306e\u4e0d\u6d3b\u6027\u5316\u7279\u6027\u306b\u5909\u66f4\u306f\u3042\u308a\u307e\u305b\u3093\u3002Silcoport-W\u306fUPS\u306eS1A\u306b\u6e96\u62e0\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6ce8\uff09DiatoDorb-W\u73ea\u85fb\u571f\u6750\u8cea\u306fChromosorb P\uff08\u30d4\u30f3\u30af\u306e\u8010\u71b1\u7149\u74e6\uff09\u3084Chromosorb &nbsp;porous polymer\u3068\u306f\u7570\u306a\u308a\u307e\u3059\u3002.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*Chromosorb P, P\/AW, P\/NAW, P\/AW-DMDCS<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">**Chromosorb 101, 102, 103, 105, 106, 107, 108, N, P, Q, R, S, T<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>DiatoSorb-W\u306f\u73ea\u85fb\u571f\u62c5\u4f53\u3067\u3059\u3002Restek\u3067\u306f\u30d1\u30c3\u30af\u30c9\u30ab\u30e9\u30e0\u3082\u3057\u304f\u306f\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u6e08\u307f\u306e\u5145\u586b\u5264(\u6db2\u76f8\u3068\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\uff05\u306f\u9078\u629e\u53ef\u80fd)\u3068\u3057\u3066\u8ca9\u58f2\u3057\u3066\u3044\u307e\u3059\u3002 Chromosorb-W \u88fd\u54c1\/\u5145\u586b\u5264\u306e\u4ee3\u66ff\u54c1\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[582],"class_list":["post-48563","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"DRCadmin","author_link":"https:\/\/discover.restek.com\/ja\/author\/drcadmin\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":582,"user_id":0,"is_guest":1,"slug":"alan-sensue","display_name":"Alan Sensue","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"1","first_name":"Alan","last_name":"Sensue","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48563","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=48563"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48563\/revisions"}],"predecessor-version":[{"id":68872,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/48563\/revisions\/68872"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=48563"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=48563"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=48563"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=48563"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=48563"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=48563"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=48563"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=48563"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=48563"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}