{"id":51740,"date":"2025-05-13T00:00:00","date_gmt":"2025-05-13T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/measure-testosterone-and-epitestosterone-levels-with-force-biphenyl\/"},"modified":"2025-11-26T19:03:24","modified_gmt":"2025-11-26T19:03:24","slug":"measure-testosterone-and-epitestosterone-levels-with-force-biphenyl","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs\/gnbl4733\/measure-testosterone-and-epitestosterone-levels-with-force-biphenyl","title":{"rendered":"Measure Testosterone and Epitestosterone Levels with Force Biphenyl"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">Testosterone is a sex hormone involved in male reproductive development and other biological processes. While testosterone is a naturally occurring hormone, it may be used illicitly as a performance enhancing substance due to its anabolic effects. This has led to athletic governing bodies like the World Anti-Doping Agency (WADA) banning the use of exogenous testosterone by athletes. Because testosterone is endogenous, simply quantifying the amount of the analyte present in a sample is not sufficient to determine whether an individual has abused testosterone for doping purposes. Instead, it is suggested to measure the ratio of testosterone to epitestosterone. Epitestosterone is an inactive epimer of testosterone, which differs only in the configuration of the hydroxyl group on carbon 17. Because epitestosterone is naturally produced in equal amounts with testosterone in the body, the ratio of testosterone to epitestosterone (T\/E) can be used to determine exogenous testosterone usage.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"295\" height=\"208\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-measure-testerone-and-epitestosterone-levels-01.png\" alt=\"testosterone structure\" class=\"wp-image-37983\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Testosterone<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"304\" height=\"198\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-measure-testerone-and-epitestosterone-levels-02.png\" alt=\"epitestosterone structure\" class=\"wp-image-37989\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-measure-testerone-and-epitestosterone-levels-02.png 304w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-measure-testerone-and-epitestosterone-levels-02-300x195.png 300w\" sizes=\"auto, (max-width: 304px) 100vw, 304px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-text-align-center wp-block-paragraph\"><strong>Epitestosterone\u00a0<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">Because testosterone and epitestosterone are epimers with the same molecular weight, chromatographic resolution of the compounds is needed for accurate quantitation. While enantiomers (another type of stereoisomer) require chiral stationary phases for separation, epimers can be more easily resolved by traditional LC columns. Biphenyl phase columns, which offer superior selectivity, are an excellent choice for resolving these compounds.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The following method was developed to separate testosterone and epitestosterone in urine. A sample was prepared by spiking both analytes at a concentration of 100 ng\/mL in urine, and then diluting it 20X with 20:80 water:methanol (v\/v), both with 0.1% formic acid. The method conditions and an example chromatogram are shown below.<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Column<\/strong><\/td><td colspan=\"3\">Force Biphenyl 100 x 2.1 mm, 3 \u00b5m (cat.#9629312)<\/td><\/tr><tr><td><strong>Mobile Phase A<\/strong><\/td><td colspan=\"3\">Water,0.1% formic acid<\/td><\/tr><tr><td><strong>Mobile Phase B<\/strong><\/td><td colspan=\"3\">Methanol, 0.1% formic acid<\/td><\/tr><tr><td><strong>Column Temperature<\/strong><\/td><td colspan=\"3\">30\u00b0C<\/td><\/tr><tr><td><strong>Sample Diluent<\/strong><\/td><td colspan=\"3\">20:80 MPA:MPB (v\/v)<\/td><\/tr><tr><td><strong>Injection Volume<\/strong><\/td><td colspan=\"3\">3 \u00b5L<\/td><\/tr><tr><td><strong>Flow Rate<\/strong><\/td><td colspan=\"3\">0.5 mL\/min<\/td><\/tr><tr><td rowspan=\"7\"><strong>Gradient<\/strong><\/td><td>Time (min)<\/td><td>%A<\/td><td>%B<\/td><\/tr><tr><td>0.00<\/td><td>20<\/td><td>80<\/td><\/tr><tr><td>4.00<\/td><td>20<\/td><td>80<\/td><\/tr><tr><td>4.10<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>5.00<\/td><td>0<\/td><td>100<\/td><\/tr><tr><td>5.10<\/td><td>20<\/td><td>80<\/td><\/tr><tr><td>6.00<\/td><td>20<\/td><td>80<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"716\" height=\"411\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-measure-testerone-and-epitestosterone-levels-03.png\" alt=\"chromatogram showing epitestosterone and testosterone peaks\" class=\"wp-image-37995\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-measure-testerone-and-epitestosterone-levels-03.png 716w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-measure-testerone-and-epitestosterone-levels-03-300x172.png 300w\" sizes=\"auto, (max-width: 716px) 100vw, 716px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><br>Using these method conditions, epitestosterone and testosterone are well separated in a six-minute runtime. With the epimers fully resolved, these method conditions are a good place to start if you are working on determining T\/E levels in urine specimens by LC-MS\/MS.<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9629312\">                                \u30ab\u30bf\u30ed\u30b0No. 9629312                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force Biphenyl, 3 \u00b5m, 100 x 2.1 mm LC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9629312\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Testosterone and epitestosterone LC-MS\/MS analysis, well separated in a six-minute runtime.<\/p>\n","protected":false},"author":13,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[9],"tags":[],"industries-application":[2153],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2299,2302],"ppma_author":[432],"class_list":["post-51740","post","type-post","status-publish","format-standard","hentry","category-blogs","industries-application-clinical","resource-technique-liquid-chromatography","resource-technique-ms-ms"],"acf":[],"taxonomy_info":{"category":[{"value":9,"label":"Blogs"}],"industries-application":[{"value":2153,"label":"Clinical"}],"resource-technique":[{"value":2299,"label":"Liquid Chromatography"},{"value":2302,"label":"MS\/MS"}]},"featured_image_src_large":false,"author_info":{"display_name":"Haley Berkland, MS","author_link":"https:\/\/discover.restek.com\/ja\/author\/haley-berkland-ms\/"},"comment_info":0,"category_info":[{"term_id":9,"name":"Blogs","slug":"blogs","term_group":0,"term_taxonomy_id":9,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":9,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs","category_parent":0}],"tag_info":false,"authors":[{"term_id":432,"user_id":13,"is_guest":0,"slug":"haley-berkland-ms","display_name":"Haley Berkland, MS","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-berkland-haley.jpg"},"author_category":"1","first_name":"Haley","last_name":"Berkland","user_url":"https:\/\/www.linkedin.com\/in\/haley-berkland-60b66517b\/","job_title":"LC Applications Scientist","description":"Haley is an LC applications scientist at Restek. She attended Duquesne University, receiving her bachelor's degree in biochemistry and a master's degree in forensic science and law. As a graduate student, she performed research on the detection of drugs of abuse in vitreous humor by LC-MS\/MS. Before joining Restek in 2023, Haley spent four years working as a forensic toxicologist. While in this role, she performed analysis of postmortem toxicology casework, identification of seized drug evidence, and development\/validation of new assays by LC-MS\/MS, GC-MS, and GC-FID."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/51740","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/13"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=51740"}],"version-history":[{"count":3,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/51740\/revisions"}],"predecessor-version":[{"id":58282,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/51740\/revisions\/58282"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=51740"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=51740"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=51740"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=51740"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=51740"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=51740"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=51740"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=51740"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=51740"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}