{"id":51743,"date":"2013-08-28T14:30:00","date_gmt":"2013-08-28T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/methyl-alcohol-in-your-air-preconcentrator-could-drive-you-to-the-ethyl-alcohol\/"},"modified":"2025-10-30T18:00:02","modified_gmt":"2025-10-30T18:00:02","slug":"methyl-alcohol-in-your-air-preconcentrator-could-drive-you-to-the-ethyl-alcohol","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blog-fr\/gnbl4735\/methyl-alcohol-in-your-air-preconcentrator-could-drive-you-to-the-ethyl-alcohol","title":{"rendered":"Methyl alcohol in your air preconcentrator could drive you to the ethyl alcohol&#8230;"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">During some recent Photochemical Assessment Monitoring Station (PAMS) analyses I had to start scanning down to 26 (you have to if you want to analyze ethylene, acetylene, ethane, and propane). So when I did this methyl alcohol popped up in ALL my analyses (i.e., blanks, standards, etc\u2026 you name it). See the figure below. My initial gut reaction was that I had a leak on my Nutech 8900DS (something that has only happened one other time in the past 2 years and thousands of runs) and I was sucking in some methanol from the lab. Now mind you, I had no other prior indication of a leak (i.e., excessive CO<sub>2<\/sub>, other laboratory solvents, etc\u2026). DESPITE THIS, I went up and down and back and forth over the Nutech. NO LEAK!!! I was racking my brain (remember\u2026 this scenario could drive you to the ethyl alcohol) and losing my hair to no avail. I could not figure out where the methanol was coming from!?!?!?<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"939\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-methyl-alcohol-in-your-air-preconcentrator-could-drive-you-to-the-ethyl-alcohol-01-939x1024.jpg\" alt=\"\" class=\"wp-image-15742\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-methyl-alcohol-in-your-air-preconcentrator-could-drive-you-to-the-ethyl-alcohol-01-939x1024.jpg 939w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-methyl-alcohol-in-your-air-preconcentrator-could-drive-you-to-the-ethyl-alcohol-01-275x300.jpg 275w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-methyl-alcohol-in-your-air-preconcentrator-could-drive-you-to-the-ethyl-alcohol-01-768x837.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-methyl-alcohol-in-your-air-preconcentrator-could-drive-you-to-the-ethyl-alcohol-01-1409x1536.jpg 1409w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-methyl-alcohol-in-your-air-preconcentrator-could-drive-you-to-the-ethyl-alcohol-01.jpg 1815w\" sizes=\"auto, (max-width: 939px) 100vw, 939px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"wp-block-paragraph\">So I bounce my problem off a colleague and right away he suggested I consider my standards. He suggested that the standard manufacturer more than likely loads the standards into the gas cylinder with methanol and then fills up with the balance gas (nitrogen). See\u2026 he saw this kind of stuff with 8260 (Purge and Trap), so it was no surprise to him. I already disconnected all internal and external standards from my system, but methanol still persisted. Well\u2026 remember 2 years and thousands of runs mean I saturated the heck out of my Nutech with methanol.&nbsp; Long story short\u2026 and you already know the answer now\u2026 I made some runs with and without standards and sure enough the theory (methanol is present in my gas standards) was confirmed.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">So\u2026 lessons to be learned:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Do not go hunting for a leak if your air preconcentrator appears to have a lot of methanol, but no prior indication of a leak.<\/li>\n\n\n\n<li>Always humble yourself to ask for the help\/opinion of fellow colleagues. Sooner than later&#8230; as this may save you some valuable time.<\/li>\n\n\n\n<li>Scan above 32 when you know methanol is on its way&#8230; unless of course you want to analyze for methanol, which will be problematic because of its ubiquitous presence in your gas standards, but that is for a whole other conversation\/blog. Note: scanning down to 35 is sufficient for EPA Method TO-15.<\/li>\n\n\n\n<li>If things continue to be bad\u2026 stick to the ethyl (not methyl) alcohol.<\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>During some recent Photochemical Assessment Monitoring Station (PAMS) analyses I had to start scanning down to 26 (you have to if you want to analyze ethylene, acetylene, ethane, and propane). So when I did this methyl alcohol popped up in&#8230;<\/p>\n","protected":false},"author":25,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[791],"tags":[],"industries-application":[2209,2208],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2315],"ppma_author":[445],"class_list":["post-51743","post","type-post","status-publish","format-standard","hentry","category-blog-fr","industries-application-analyses-de-lair","industries-application-environnement","resource-technique-echantillonnage-dair"],"acf":[],"taxonomy_info":{"category":[{"value":791,"label":"Blog"}],"industries-application":[{"value":2209,"label":"Analyses de l'air"},{"value":2208,"label":"Environnement"}],"resource-technique":[{"value":2315,"label":"\u00c9chantillonnage d'air"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jason S. Herrington, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/jason-s-herrington-phd\/"},"comment_info":0,"category_info":[{"term_id":791,"name":"Blog","slug":"blog-fr","term_group":0,"term_taxonomy_id":791,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":791,"category_count":457,"category_description":"","cat_name":"Blog","category_nicename":"blog-fr","category_parent":0}],"tag_info":false,"authors":[{"term_id":445,"user_id":25,"is_guest":0,"slug":"jason-s-herrington-phd","display_name":"Jason S. Herrington, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herrington-jason.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-herrington-jason.png"},"author_category":"1","first_name":"Jason","last_name":"Herrington","user_url":"https:\/\/www.linkedin.com\/in\/jason-herrington-97b0b620\/%20","job_title":"VP, Reference Standards Business","description":"Jason joined Restek in 2011 after spending over 10 years in environmental analysis, most notably as a postdoctoral research fellow with the U.S. EPA focusing on the development of techniques for organic speciation of ambient gas-phase and particulate air toxics. He has a BS in environmental sciences from Rutgers University and a PhD in exposure science from The University of Medicine and Dentistry of New Jersey. His wide-ranging work has been published in over a dozen peer-reviewed manuscripts and presented around the world. As a senior scientist with Restek, Jason is heavily involved with developing new air products and applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/51743","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/25"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=51743"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/51743\/revisions"}],"predecessor-version":[{"id":59383,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/51743\/revisions\/59383"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=51743"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=51743"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=51743"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=51743"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=51743"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=51743"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=51743"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=51743"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=51743"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}