{"id":51813,"date":"2018-06-04T14:30:00","date_gmt":"2018-06-04T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/uncategorized\/the-main-source-of-artificial-trans-fatty-acids-is-banned-on-june-18-2018-are-we-ready\/"},"modified":"2025-12-11T16:18:16","modified_gmt":"2025-12-11T16:18:16","slug":"the-main-source-of-artificial-trans-fatty-acids-is-banned-on-june-18-2018-are-we-ready","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4819\/the-main-source-of-artificial-trans-fatty-acids-is-banned-on-june-18-2018-are-we-ready","title":{"rendered":"The main source of artificial trans fatty acids is banned on June 18, 2018. Are we ready?"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">This blog a part of a series:&nbsp;part 2,&nbsp;part 3, and&nbsp;part 4<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">One of the leading causes of deaths in the world is heart disease, accounting for approximately 24% of deaths in the&nbsp;USA in 2015.<sup>1<\/sup>&nbsp;One of the factors linked to cardiovascular diseases is consumption of artificial&nbsp;<em>trans<\/em>&nbsp;fatty acids (TFAs). Artificial TFAs are a by-product of partially hydrogenated vegetable oils, which were introduced as a replacement for saturated fatty acids found in butter, after concerns about adverse health effects. The TFAs have a benefit of a&nbsp;higher boiling point than their&nbsp;<em>cis&nbsp;<\/em>counterparts allowing for denser packing leading to a more solid form of hydrogenated oils.<sup>2<\/sup>&nbsp;However, this is not the only way that&nbsp;<em>cis<\/em>&nbsp;and<em>&nbsp;trans<\/em>&nbsp;fatty acids differ. While&nbsp;<em>cis<\/em>&nbsp;fatty acids help maintain a healthy balance between low-density and high-density lipoprotein cholesterols (LDL and HDL, respectively), the artificial TFAs increase LDL levels and decrease the HDL levels. In addition, TFAs increase total levels of cholesterol, effectively increase the risk of cardiovascular disease.<sup>2<\/sup><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">There is a push to eliminate the partially hydrogenated oils (the main source of artificial TFAs) globally. In Europe Denmark was the first to execute legislative implementation in 2004, followed by Austria, Sweden, Hungary and Latvia, while other European countries implemented guidelines for voluntary self-regulation.<sup>3<\/sup>&nbsp;In the United States, the FDA declared partially hydrogenated oils as not \u201cgenerally recognized as safe\u201d in June of 2015 and food manufacturers have been given three years to phase them out (unless otherwise approved).<sup>4<\/sup>&nbsp;On May 14, 2018, World Health Organization (WHO) together with the non-profit Resolve to Save Lives released a step-by-step guide for the elimination of industrially produced TFAs with the goal of completely phasing out partially hydrogenated oil and artificial TFAs by 2023.<sup>5<\/sup><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Less than a month away from the US ban of artificial TFAs, we have decided to test products that traditionally contain TFAs\u2013 margarine stick, shortening and butter flavored popcorn. The margarine and shortening were purchased at a local grocery store, while the popcorn was bought at a dollar store. The fatty acids were trans-esterified using sodium methoxide, following a method by Ichihara&nbsp;<em>et al<\/em><sup>6<\/sup>&nbsp;and analyzed on multiple Restek columns, namely&nbsp;Rtx-2330,&nbsp;Rt-2560, and&nbsp;FAMEWAX. All these columns can be used for fatty acid methyl esters (FAMEs) analysis, where Rtx-2330 is a general use polar columns with cyano-polymer stationary phase, while FAMEWAX is formulated to deliver comparable elution order to other Carbowax columns with better FAMEs resolution. RT-2560 is specifically formulated to ensure accurate quantification of critical&nbsp;<em>cis\/trans<\/em>&nbsp;FAMEs.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Let\u2019s start with the individual products. Margarines previously contained 10-20 % of saturated, 30-40 % monounsaturated, 20-30% polyunsaturated fatty acids and approximately 15% TFAs.<sup>7<\/sup>&nbsp;We tested the new margarine and the composition was approximately 40% saturated (peaks 1-6, Fig. 1), 23% monounsaturated (peaks 7a- 8, Fig. 1), 37% polyunsaturated fatty acids (peaks 9-10, Fig. 1) and no TFAs (peak 7b, Fig.1). This shift is caused mostly by addition of palm and palm kernel oils, which contain more saturated fatty acids (approximately 50% and 80%, respectively).<sup>8-9<\/sup>&nbsp;In Figure 1 we can see chromatograms of the trans-esterified margarine stick without any alterations (red), and a sample spiked with methyl elaidate (methyl&nbsp;<em>trans<\/em>-9-octadecenoate), the most common artificial TFA added.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br role=\"presentation&quot;\" data-uw-rm-sr=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"img-fluid wp-image-47846 size-medium\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-the-main-source-of-artificial-trans-fatty-acids-is-banned-on-june-18-2018.-are-we-ready-01.png\" alt=\"Figure 1: GC Analysis of trans-esterified margarine stick. Red \u2013 original sample, blue \u2013 sample spiked with methyl elaidate (peak 7b).\" width=\"2122\" height=\"2032\" data-uw-rm-ima-original=\"figure 1: gc analysis of trans-esterified margarine stick. red \u2013 original sample, blue \u2013 sample spiked with methyl elaidate (peak 7b).\" title=\"-\"><br role=\"presentation\" data-uw-rm-sr=\"\">Figure 1: GC Analysis of trans-esterified margarine stick. Red \u2013 original sample, blue \u2013 sample spiked with methyl elaidate (peak 7b).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The differences between the individual columns are apparent. Both cyano polymer-based columns (Rtx-2330 and Rt-2560, Fig. 1A and B, respectively) elute<em>&nbsp;trans<\/em>&nbsp;isomers before the&nbsp;<em>cis<\/em>. This is particularly advantageous because even when using GC-MS we cannot distinguish the isomers based on their EI spectra. This helps to unambiguously determine the identity of peak 8 as methyl&nbsp;<em>cis<\/em>-11-octadecenoate. When it comes to Carbowax polymer-based columns,&nbsp;<em>trans<\/em>&nbsp;isomers elute right after its&nbsp;<em>cis<\/em>&nbsp;counterparts. Nevertheless, FAMEWAX column is capable of separating the&nbsp;<em>cis\/trans<\/em>&nbsp;isomers (we can see two distinct peaks, Fig. 1C peak 7a and 7b).<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The next product we analyzed was shortening. Traditionally shortening can contain as much as 40% of industrial TFAs.<sup>10<\/sup>&nbsp;As with the margarine, the shortening we bought had no significant TFAs present (Fig. 2). In contrast to the margarine, the polyunsaturated fatty acids in shortening accounted for almost 50% of FAMEs, which was also in direct contradiction with the product\u2019s label of 20.8% polyunsaturated fatty acids.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br role=\"presentation\" data-uw-rm-sr=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"img-fluid wp-image-47848 size-medium\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-the-main-source-of-artificial-trans-fatty-acids-is-banned-on-june-18-2018.-are-we-ready-02.png\" alt=\"Figure 2: GC Analysis of trans-esterified shortening\" width=\"2435\" height=\"1979\" data-uw-rm-ima-original=\"figure 2: gc analysis of trans-esterified shortening\" title=\"-\"><br role=\"presentation\" data-uw-rm-sr=\"\">Figure 2: GC Analysis of trans-esterified shortening<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">It is worth noting that the relative content saturated of fatty acids\u2019 in shortening is lower than in margarine. This is most likely due to the absence of palm kernel oil, however, the palm oil was still present. Our third sample, butter-flavored popcorn (Fig. 3), contained no palm or palm kernel oil, resulting in the least amount of saturated fatty acids, approximately 16%. In addition, the popcorn contained the most monounsaturated fatty acids (mainly oleic acid) \u2013 approximately 67% of total FAMEs. This can be attributed to the oil source \u2013 while fats in both margarine and shortening are comprised of soybean oil, palm oil and palm kernel oil (margarine only), popcorn\u2019s source of fat is canola oil and fully hydrogenated cottonseed oil.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><br role=\"presentation\" data-uw-rm-sr=\"\"><img loading=\"lazy\" decoding=\"async\" class=\"img-fluid wp-image-47847 size-medium\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-the-main-source-of-artificial-trans-fatty-acids-is-banned-on-june-18-2018.-are-we-ready-03.png\" alt=\"Figure 3: GC Analysis of trans-esterified popcorn\u2019s butter flavoring\" width=\"2394\" height=\"2394\" data-uw-rm-ima-original=\"figure 3: gc analysis of trans-esterified popcorn\u2019s butter flavoring\" title=\"-\"><br role=\"presentation\" data-uw-rm-sr=\"\">Figure 3: GC Analysis of trans-esterified popcorn\u2019s butter flavoring<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Overall, our evaluation confirmed that US food producers ditched the artificial TFAs. On the other hand, the introduction of palm and palm kernel oil means increases in the saturated fatty acids\u2019 content. When it comes to column selection, FAMEWAX provides great separation of the majority of FAMEs with shorter analysis times (especially for longer chains), however, if you need to quantitatively determine the TFAs, Rt-2560 is the best choice.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">References:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><a data-uw-rm-brl=\"false\" href=\"https:\/\/www.cdc.gov\/nchs\/fastats\/leading-causes-of-death.htm\" target=\"_blank\" rel=\"noopener\">https:\/\/www.cdc.gov\/nchs\/fastats\/leading-causes-of-death.htm<\/a><\/li>\n\n\n\n<li><a data-uw-rm-brl=\"false\" href=\"https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3955571\/\" target=\"_blank\" rel=\"noopener\">https:\/\/www.ncbi.nlm.nih.gov\/pmc\/articles\/PMC3955571\/<\/a><\/li>\n\n\n\n<li>https:\/\/ec.europa.eu\/food\/sites\/food\/files\/safety\/docs\/fs_labelling-nutrition_trans-fats-report_en.pdf<\/li>\n\n\n\n<li><a data-uw-rm-brl=\"false\" href=\"https:\/\/www.federalregister.gov\/documents\/2015\/06\/17\/2015-14883\/final-determination-regarding-partially-hydrogenated-oils\" target=\"_blank\" rel=\"noopener\">https:\/\/www.federalregister.gov\/documents\/2015\/06\/17\/2015-14883\/final-determination-regarding-partially-hydrogenated-oils<\/a><\/li>\n\n\n\n<li><a data-uw-rm-brl=\"false\" href=\"http:\/\/www.who.int\/news-room\/detail\/14-05-2018-who-plan-to-eliminate-industrially-produced-trans-fatty-acids-from-global-food-supply\" target=\"_blank\" rel=\"noopener\">http:\/\/www.who.int\/news-room\/detail\/14-05-2018-who-plan-to-eliminate-industrially-produced-trans-fatty-acids-from-global-food-supply<\/a><\/li>\n\n\n\n<li><a data-uw-rm-brl=\"false\" href=\"https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0003269715005357\" target=\"_blank\" rel=\"noopener\">https:\/\/www.sciencedirect.com\/science\/article\/pii\/S0003269715005357<\/a><\/li>\n\n\n\n<li>https:\/\/ndb.nal.usda.gov\/ndb\/foods\/show\/04629<\/li>\n\n\n\n<li>https:\/\/ndb.nal.usda.gov\/ndb\/foods\/show\/299928<\/li>\n\n\n\n<li>https:\/\/ndb.nal.usda.gov\/ndb\/foods\/show\/299949<\/li>\n\n\n\n<li>https:\/\/ndb.nal.usda.gov\/ndb\/foods\/show\/04667<\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>This blog a part of a series: part 2, part 3, and part 4 One of the leading causes of deaths in the world is heart disease, accounting for approximately 24% of deaths in the USA in 2015.1 One of&#8230;<\/p>\n","protected":false},"author":50,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[],"industries-application":[2214,2215,2216],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2316],"ppma_author":[591],"class_list":["post-51813","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","industries-application-industrie-agroalimentaire","industries-application-qualite-alimentaire","industries-application-securite-alimentaire","resource-technique-chromatographie-en-phase-gazeuse-gc"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"industries-application":[{"value":2214,"label":"Industrie Agroalimentaire"},{"value":2215,"label":"Qualit\u00e9 Alimentaire"},{"value":2216,"label":"S\u00e9curit\u00e9 alimentaire"}],"resource-technique":[{"value":2316,"label":"Chromatographie en phase gazeuse (GC)"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jana Hepner, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/jana-hepner-phd\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":591,"user_id":50,"is_guest":0,"slug":"jana-hepner-phd","display_name":"Jana Hepner, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hepner-jana.jpg"},"author_category":"1","first_name":"Jana","last_name":"Hepner","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/51813","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/50"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=51813"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/51813\/revisions"}],"predecessor-version":[{"id":73501,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/51813\/revisions\/73501"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=51813"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=51813"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=51813"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=51813"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=51813"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=51813"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=51813"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=51813"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=51813"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}