{"id":60395,"date":"2026-06-25T14:00:00","date_gmt":"2026-06-25T14:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=60395"},"modified":"2026-09-25T06:58:10","modified_gmt":"2026-09-25T06:58:10","slug":"lab-supplies-for-pfas-analysis-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evar3498-ja\/lab-supplies-for-pfas-analysis-japan","title":{"rendered":"PFAS\u5206\u6790\u306b\u304a\u3051\u308b\u898f\u5236\u3068\u524d\u51e6\u7406\u6cd5\uff1a\u6700\u9069\u306a\u30e9\u30dc\u7528\u54c1\u306e\u9078\u5b9a\u30ac\u30a4\u30c9"},"content":{"rendered":"\n<h2 class=\"wp-block-heading\">PFAS\u5206\u6790\u306e\u305f\u3081\u306e\u30e9\u30dc\u7528\u54c1\u3092\u30e1\u30bd\u30c3\u30c9\u5225\u306b\u3054\u7d39\u4ecb\u3057\u307e\u3059<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\uff08\u30d1\u30fc\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff09\u306f\u3001\u305d\u306e\u5f37\u529b\u306a\u70ad\u7d20-\u30d5\u30c3\u7d20\u7d50\u5408\u306b\u3088\u308a\u300c\u6c38\u9060\u306e\u5316\u5b66\u7269\u8cea\u300d\u3068\u547c\u3070\u308c\u3001\u6975\u3081\u3066\u5206\u89e3\u3055\u308c\u306b\u304f\u304f\u3001\u74b0\u5883\u4e2d\u306b\u5e83\u304f\u5b58\u5728\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u305f\u3081\u3001\u30e9\u30dc\u7528\u54c1\u3084\u5b9f\u9a13\u5668\u5177\u306b\u3082PFAS\u304c\u4ed8\u7740\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u3042\u308a\u3001\u610f\u56f3\u3057\u306a\u3044\u6c5a\u67d3\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u5206\u6790\u7cbe\u5ea6\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30e9\u30dc\u7528\u54c1\u3084\u74b0\u5883\u4e2d\u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9 PFAS\u3092\u4f4e\u6e1b\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6c5a\u67d3\u3092\u9632\u3050\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u306f\u758e\u6c34\u6027\u3068\u89aa\u6c34\u6027\u306e\u4e21\u65b9\u3092\u6301\u3064\u754c\u9762\u6d3b\u6027\u7279\u6027\u3092\u5099\u3048\u3066\u304a\u308a\u3001\u5206\u5b50\u4e2d\u306e\u30d5\u30c3\u7d20\u539f\u5b50\u306e\u5f71\u97ff\u306a\u3069\u304b\u3089\u3001\u30ac\u30e9\u30b9\u5bb9\u5668\u3084\u30d4\u30da\u30c3\u30c8\u306a\u3069\u3001\u3055\u307e\u3056\u307e\u306a\u6750\u6599\u306e\u8868\u9762\u306b\u5438\u7740\u3057\u3084\u3059\u3044\u6027\u8cea\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u304c\u901a\u904e\u3059\u308b\u3042\u3089\u3086\u308b\u6d41\u8def\u3067PFAS\u306e\u4ed8\u7740\u3084\u6c5a\u67d3\u304c\u306a\u3044\u304b\u3001\u307e\u305f\u306f\u30b5\u30f3\u30d7\u30eb\u5185\u306ePFAS\u304c\u5438\u7740\u3055\u308c\u3066\u3044\u306a\u3044\u304b\u3092\u78ba\u8a8d\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u5206\u6790\u306b\u9069\u3057\u305f\u30e9\u30dc\u7528\u54c1\u3092\u9078\u3076\u306e\u306f\u3001\u3053\u3046\u3057\u305f\u6027\u8cea\u304c\u5f71\u97ff\u3059\u308b\u305f\u3081\u975e\u5e38\u306b\u96e3\u3057\u3044\u8ab2\u984c\u3067\u3059\u3002\u3055\u3089\u306b\u3001PFAS\u5206\u6790\u306b\u306f\u591a\u304f\u306e\u30e1\u30bd\u30c3\u30c9\u304c\u5b58\u5728\u3057\u3001\u305d\u308c\u305e\u308c\u306b\u7570\u306a\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u3084\u5206\u6790\u6a5f\u5668\u304c\u6c42\u3081\u3089\u308c\u308b\u305f\u3081\u3001\u88fd\u54c1\u9078\u629e\u306f\u4e00\u5c64\u8907\u96d1\u5316\u3057\u307e\u3059\u3002\u7279\u306b\u3001\u653f\u5e9c\u306e\u30ac\u30a4\u30c9\u30e9\u30a4\u30f3\u306b\u307e\u3060\u8a18\u8f09\u3055\u308c\u3066\u3044\u306a\u3044\u8d85\u77ed\u9396PFAS\u3084\u77ed\u9396PFAS\u3068\u3044\u3063\u305f\u5fae\u91cf\u30ec\u30d9\u30eb\u306e\u5316\u5408\u7269\u3092\u6b63\u78ba\u306b\u691c\u51fa\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u6700\u9069\u306a\u30e9\u30dc\u7528\u54c1\u306e\u9078\u5b9a\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u6b21\u306e\u30da\u30fc\u30b8\u306b\u63b2\u8f09\u3055\u308c\u3066\u3044\u308b\u88fd\u54c1\u30ac\u30a4\u30c9\u30c6\u30fc\u30d6\u30eb\u3092\u53c2\u8003\u306b\u3059\u308b\u3053\u3068\u3067\u3001PFAS\u5206\u6790\u306b\u9069\u3057\u305f\u88fd\u54c1\u3092\u898b\u3064\u3051\u308b\u624b\u52a9\u3051\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u30ac\u30a4\u30c9\u306b\u306f\u3001\u7c73\u56fd\u306eCDC\u3001EPA\u3001FDA\u3001USDA\u3001\u30e8\u30fc\u30ed\u30c3\u30d1\u306eDIN\u3001\u56fd\u969b\u898f\u683c\u3067\u3042\u308bASTM\u3084ISO\u306b\u6e96\u62e0\u3057\u305f\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306b\u5bfe\u5fdc\u3059\u308b\u88fd\u54c1\u304c\u7d39\u4ecb\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u9078\u5b9a\u3057\u305f\u88fd\u54c1\u304c\u5206\u6790\u5bfe\u8c61\u3068\u3059\u308bPFAS\u3092\u542b\u307e\u305a\u3001\u307e\u305f\u6c42\u3081\u3089\u308c\u308b\u5206\u6790\u30ec\u30d9\u30eb\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u5fc5\u305a\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u6b21\u306e\u30da\u30fc\u30b8\u306b\u63b2\u8f09\u3055\u308c\u3066\u3044\u308b\u88fd\u54c1\u30ac\u30a4\u30c9\u30c6\u30fc\u30d6\u30eb\u3092\u53c2\u8003\u306b\u3059\u308b\u3053\u3068\u3067\u3001PFAS\u5206\u6790\u306b\u9069\u3057\u305f\u88fd\u54c1\u3092\u898b\u3064\u3051\u308b\u624b\u52a9\u3051\u304c\u5f97\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u30ac\u30a4\u30c9\u306b\u306f\u3001\u7c73\u56fd\u306eCDC\u3001EPA\u3001FDA\u3001USDA\u3001\u30e8\u30fc\u30ed\u30c3\u30d1\u306eDIN\u3001\u56fd\u969b\u898f\u683c\u3067\u3042\u308bASTM\u3084ISO\u306b\u6e96\u62e0\u3057\u305f\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306b\u5bfe\u5fdc\u3059\u308b\u88fd\u54c1\u304c\u7d39\u4ecb\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u9078\u5b9a\u3057\u305f\u88fd\u54c1\u304c\u5206\u6790\u5bfe\u8c61\u3068\u3059\u308bPFAS\u3092\u542b\u307e\u305a\u3001\u307e\u305f\u6c42\u3081\u3089\u308c\u308b\u5206\u6790\u30ec\u30d9\u30eb\u306b\u5bfe\u5fdc\u3057\u3066\u3044\u308b\u3053\u3068\u3092\u5fc5\u305a\u78ba\u8a8d\u3057\u3066\u304f\u3060\u3055\u3044\u3002 \u3054\u8cea\u554f\u304c\u3042\u308b\u5834\u5408\u3001\u307e\u305f\u306fPFAS\u5206\u6790\u306b\u3064\u3044\u3066\u3055\u3089\u306b\u8a73\u3057\u304f\u304a\u77e5\u308a\u306b\u306a\u308a\u305f\u3044\u5834\u5408\u306f\u3001<a href=\"https:\/\/discover.restek.com\/ja\/pfas-analysis\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/pfas-analysis\/\" rel=\"noreferrer noopener\">\u300cPFAS\u5206\u6790\u306e\u30d1\u30fc\u30c8\u30ca\u30fc\u300d<\/a>\u3067\u305d\u306e\u4ed6\u306e\u30ea\u30bd\u30fc\u30b9\u3092\u3054\u89a7\u306b\u306a\u308b\u304b\u3001\u304a\u8fd1\u304f\u306eRestek\u62c5\u5f53\u8005\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30e1\u30bd\u30c3\u30c9\u5225\u306ePFAS\u5206\u6790\u306e\u305f\u3081\u306e\u30e9\u30dc\u7528\u54c1<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Table\u306e\u898b\u51fa\u3057\u306b\u3042\u308b\u30e1\u30bd\u30c3\u30c9\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u4e0b\u3055\u3044\u3002\u305d\u306e\u30e1\u30bd\u30c3\u30c9\u306e\u6982\u8981\u3068\u63a8\u5968\u88fd\u54c1\u306e\u30ea\u30b9\u30c8\u306b\u30a2\u30af\u30bb\u30b9\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30e9\u30dc\u3067\u5206\u6790\u3092\u59cb\u3081\u308b\u524d\u306b\u3001\u7121\u6599\u306e\u30aa\u30f3\u30e9\u30a4\u30f3\u30c4\u30fc\u30eb<a href=\"https:\/\/ez.restek.com\/proezlc\/en\/ja\" target=\"_blank\" rel=\"noreferrer noopener\">Pro <em>EZ<\/em>LC chromatogram modeler<\/a>\u3092\u4f7f\u3044\u3001\u30c7\u30b9\u30af\u4e0a\u3067\u4e8b\u524d\u306b\u30e1\u30bd\u30c3\u30c9\u3092\u30b7\u30df\u30e5\u30ec\u30fc\u30b7\u30e7\u30f3\u3059\u308b\u3053\u3068\u3082\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u5206\u6790<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4284-ja\/pfas-analysis-by-u-s-epa-method-537-1-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4284-ja\/pfas-analysis-by-u-s-epa-method-537-1-for-drinking-water-japan\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles\/evar4285-ja\/pfas-analysis-by-u-s-epa-method-533-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4285-ja\/pfas-analysis-by-u-s-epa-method-533-for-drinking-water-japan\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4286-ja\/pfas-analysis-by-u-s-epa-method-16-for-aqueous-solid-biosolids-and-tissue-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4286-ja\/pfas-analysis-by-u-s-epa-method-16-for-aqueous-solid-biosolids-and-tissue-japan\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles\/evar4287-ja\/pfas-analysis-by-u-s-epa-method-otm-45-for-emissions\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4287-ja\/pfas-analysis-by-u-s-epa-method-otm-45-for-emissions\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4289-ja\/pfas-analysis-by-u-s-epa-method-8327-for-surface-water-groundwater-and-wastewater\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4289-ja\/pfas-analysis-by-u-s-epa-method-8327-for-surface-water-groundwater-and-wastewater\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4290-ja\/pfas-analysis-by-u-s-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4290-ja\/pfas-analysis-by-u-s-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma-japan\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/cfar4291-ja\/pfas-analysis-by-cdc-6304-09-for-serum-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/cfar4291-ja\/pfas-analysis-by-cdc-6304-09-for-serum-japan\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4292-ja\/pfas-analysis-by-u-s-fda-c-010-03-for-food-and-feed-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4292-ja\/pfas-analysis-by-u-s-fda-c-010-03-for-food-and-feed-japan\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4298-ja\/pfas-analysis-by-din-en-17892-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4298-ja\/pfas-analysis-by-din-en-17892-for-drinking-water-japan\"><strong>DIN EN 17892*<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4299-ja\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4299-ja\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge-japan\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4300-ja\/pfas-analysis-by-iso-21675-2019-for-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4300-ja\/pfas-analysis-by-iso-21675-2019-for-water-japan\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4301-ja\/pfas-analysis-by-iso-23702-1-2023-for-leather-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4301-ja\/pfas-analysis-by-iso-23702-1-2023-for-leather-japan\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4303-ja\/pfas-analysis-by-astm-d7968-23-for-soil-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4303-ja\/pfas-analysis-by-astm-d7968-23-for-soil-japan\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4304-ja\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4304-ja\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater-japan\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4305-ja\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4305-ja\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples-japan\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td colspan=\"16\"><strong><strong>C18\u56fa\u5b9a\u76f8<\/strong><\/strong><\/td><\/tr><tr><td>PFAS delay column:<br>5 \u00b5m, 50 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/27854\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 27854<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>PFAS delay column: 5 \u00b5m, 50 x 3.0 mm<br>(cat.# 580959 [custom product])<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Force C18 FPP column:<br>1.8 \u03bcm, 50 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9634252\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 9634252<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Raptor C18 SPP column:<br>2.7 \u03bcm, 50 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9304A52\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 9304A52<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td colspan=\"16\"><em><em>\u4ed6\u306e\u30b5\u30a4\u30ba\u306eC18 column\u306b\u3064\u3044\u3066\u306f&nbsp;<a href=\"https:\/\/www.restek.com\/c\/lc-pfas?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089\u3092\u3054\u53c2\u7167\u4e0b\u3055\u3044\u3002<\/a><\/em><\/em><\/td><\/tr><tr><td colspan=\"16\"><strong><strong>\u77ed\u9396\u30fb\u8d85\u77ed\u9396PFAS\u5411\u3051\u56fa\u5b9a\u76f8<\/strong><\/strong><\/td><\/tr><tr><td>Raptor Polar X:<br>2.7 \u00b5m, 50 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9311A52\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 9311A52<\/a>)<\/td><td colspan=\"15\">\u30a4\u30bd\u30af\u30e9\u30c6\u30a3\u30c3\u30af\u30e1\u30bd\u30c3\u30c9\u3067\u306e\u8d85\u77ed\u9396(C1-C3)PFAS\u5206\u6790\u306b\u6700\u9069\u3002&nbsp;<a href=\"https:\/\/doi.org\/10.1016\/j.jcoa.2023.100098\" target=\"_blank\" rel=\"noreferrer noopener\">\u53c2\u8003\u8cc7\u6599\uff08\u82f1\u8a9e\u8a18\u4e8b\u306e\u307f\uff09<\/a><\/td><\/tr><tr><td>Ultra IBD Inert:<br>3 \u00b5m, 100 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9175312-t\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/p\/9175312-t\" rel=\"noreferrer noopener\">cat.# 9175312-T<\/a>)<\/td><td colspan=\"15\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u30e1\u30bd\u30c3\u30c9\u3067\u306e\u8d85\u77ed\u9396\u3001\u77ed\u9396\u3001\u4e2d\u9396\u3001\u9577\u9396(C1 &#8211; C14)PFAS\u5206\u6790\u306b\u6700\u9069\u3002&nbsp;<a href=\"https:\/\/discover.restek.com\/ja\/application-notes-ja\/cfan4273-ja\/c1-c10-pfas-analysis-in-human-plasma-and-serum-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/CFAN4273-JA\/c1-c10-pfas-analysis-in-human-plasma-and-serum-japan\" rel=\"noreferrer noopener\">\u53c2\u8003\u8a18\u4e8b\u300c\u8d85\u77ed\u9396PFAS\u306e\u8840\u6f3f\u304a\u3088\u3073\u8840\u6e05\u4e2d\u306e\u9ad8\u611f\u5ea6\u5206\u6790&nbsp; NIST\u6a19\u6e96\u53c2\u7167\u7269\u8cea\u3092\u7528\u3044\u305fLC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u300d<\/a><\/td><\/tr><tr><td colspan=\"16\"><strong><strong>\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0<\/strong><\/strong><\/td><\/tr><tr><td>UltraShield UHPLC precolumn filter:<br>0.2 \u00b5m frit (<a href=\"https:\/\/www.restek.com\/p\/25809\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 25809<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>EXP direct connect holder for EXP guard cartridges:<br>(<a href=\"https:\/\/www.restek.com\/p\/25808\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 25808<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>Raptor C18 EXP guard column cartridge:<br>2.7 \u03bcm, 5 x 2.1 mm (<a href=\"https:\/\/www.restek.com\/p\/9304A0252\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 9304A0252<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6ce8:<\/strong> \u4e0a\u8a18\u306e\u88fd\u54c1\u306e\u3046\u3061\u306e\u3044\u304f\u3064\u304b\u306f\u3001\u5404\u30e1\u30bd\u30c3\u30c9\u306e\u88fd\u54c1\u8aac\u660e\u3068\u6b63\u78ba\u306b\u306f\u4e00\u81f4\u3057\u3066\u3044\u306a\u3044\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">*DIN EN 17892\u306e\u9644\u5c5e\u66f8\u306b\u306f\u3001\u4ee5\u4e0b\u306e\u30b5\u30a4\u30ba\u306e\u30ab\u30e9\u30e0\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002 Force C18 FPP column: 1.8 \u03bcm, 100 x 3.0 mm (cat.# 963421E) and Raptor C18 SPP column: 2.7 \u03bcm, 100 x 2.1 mm (cat.# 9304A12)<\/p>\n\n\n\n<div style=\"height:55px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u8a73\u7d30\u306a\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306b\u3064\u3044\u3066\u306f\u3001\u4e0b\u8a18\u306e\u88fd\u54c1\u30ab\u30bf\u30ed\u30b0\u756a\u53f7\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u4e0b\u3055\u3044\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4284-ja\/pfas-analysis-by-u-s-epa-method-537-1-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4284-ja\/pfas-analysis-by-u-s-epa-method-537-1-for-drinking-water-japan\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles\/evar4285-ja\/pfas-analysis-by-u-s-epa-method-533-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4285-ja\/pfas-analysis-by-u-s-epa-method-533-for-drinking-water-japan\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4286-ja\/pfas-analysis-by-u-s-epa-method-16-for-aqueous-solid-biosolids-and-tissue-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4286-ja\/pfas-analysis-by-u-s-epa-method-16-for-aqueous-solid-biosolids-and-tissue-japan\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles\/evar4287-ja\/pfas-analysis-by-u-s-epa-method-otm-45-for-emissions\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4287-ja\/pfas-analysis-by-u-s-epa-method-otm-45-for-emissions\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4289-ja\/pfas-analysis-by-u-s-epa-method-8327-for-surface-water-groundwater-and-wastewater\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4289-ja\/pfas-analysis-by-u-s-epa-method-8327-for-surface-water-groundwater-and-wastewater\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4290-ja\/pfas-analysis-by-u-s-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4290-ja\/pfas-analysis-by-u-s-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma-japan\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/cfar4291-ja\/pfas-analysis-by-cdc-6304-09-for-serum-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/cfar4291-ja\/pfas-analysis-by-cdc-6304-09-for-serum-japan\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4292-ja\/pfas-analysis-by-u-s-fda-c-010-03-for-food-and-feed-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4292-ja\/pfas-analysis-by-u-s-fda-c-010-03-for-food-and-feed-japan\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4298-ja\/pfas-analysis-by-din-en-17892-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4298-ja\/pfas-analysis-by-din-en-17892-for-drinking-water-japan\"><strong>DIN EN 17892<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4299-ja\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4299-ja\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge-japan\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4300-ja\/pfas-analysis-by-iso-21675-2019-for-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4300-ja\/pfas-analysis-by-iso-21675-2019-for-water-japan\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4301-ja\/pfas-analysis-by-iso-23702-1-2023-for-leather-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4301-ja\/pfas-analysis-by-iso-23702-1-2023-for-leather-japan\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4303-ja\/pfas-analysis-by-astm-d7968-23-for-soil-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4303-ja\/pfas-analysis-by-astm-d7968-23-for-soil-japan\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4304-ja\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4304-ja\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater-japan\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4305-ja\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4305-ja\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples-japan\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td>PFAS 24 calibration standard: 1 \u00b5g\/mL, methanol (1 mM KOH) (<a href=\"https:\/\/www.restek.com\/p\/30733\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 30733)<\/a><\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>PFAS 28 calibration standard: 1 \u00b5g\/mL, methanol (1 mM KOH) (<a href=\"https:\/\/www.restek.com\/p\/30734\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 30734<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>PFAS EPA Method 533 Analyte Primary Dilution Standard (PDS) 2 \u00b5g\/mL, Methanol (1 mM NaOH)\/2-Propanol (98:2), 1 mL\/ampul (<a href=\"https:\/\/www.restek.com\/p\/30840\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/p\/30840\" target=\"_blank\" rel=\"noopener\">cat.# 30840<\/a>)<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>PFAS EPA Method 537.1 Analyte Primary Dilution Standard (PDS) 2 \u00b5g\/mL, Methanol (1 mM NaOH)\/2-Propanol (98:2), 1 mL\/ampul (<a href=\"https:\/\/www.restek.com\/p\/30841\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/p\/30841\" target=\"_blank\" rel=\"noopener\">cat.# 30841<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6ce8:<\/strong> \u4e0a\u8a18\u306e\u88fd\u54c1\u306e\u3046\u3061\u306e\u3044\u304f\u3064\u304b\u306f\u3001\u5404\u30e1\u30bd\u30c3\u30c9\u306e\u88fd\u54c1\u8aac\u660e\u3068\u6b63\u78ba\u306b\u306f\u4e00\u81f4\u3057\u3066\u3044\u306a\u3044\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:55px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u30b5\u30f3\u30d7\u30eb\u51e6\u7406<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><strong>\u88fd\u54c1<\/strong><br><strong>\u30ab\u30c6\u30b4\u30ea\u30fc<\/strong><\/td><td><strong><strong>\u88fd\u54c1\u8aac\u660e<\/strong><\/strong><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4284-ja\/pfas-analysis-by-u-s-epa-method-537-1-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4284-ja\/pfas-analysis-by-u-s-epa-method-537-1-for-drinking-water-japan\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles\/evar4285-ja\/pfas-analysis-by-u-s-epa-method-533-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4285-ja\/pfas-analysis-by-u-s-epa-method-533-for-drinking-water-japan\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4286-ja\/pfas-analysis-by-u-s-epa-method-16-for-aqueous-solid-biosolids-and-tissue-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4286-ja\/pfas-analysis-by-u-s-epa-method-16-for-aqueous-solid-biosolids-and-tissue-japan\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles\/evar4287-ja\/pfas-analysis-by-u-s-epa-method-otm-45-for-emissions\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4287-ja\/pfas-analysis-by-u-s-epa-method-otm-45-for-emissions\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4289-ja\/pfas-analysis-by-u-s-epa-method-8327-for-surface-water-groundwater-and-wastewater\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4289-ja\/pfas-analysis-by-u-s-epa-method-8327-for-surface-water-groundwater-and-wastewater\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4290-ja\/pfas-analysis-by-u-s-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4290-ja\/pfas-analysis-by-u-s-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma-japan\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/cfar4291-ja\/pfas-analysis-by-cdc-6304-09-for-serum-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/cfar4291-ja\/pfas-analysis-by-cdc-6304-09-for-serum-japan\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4292-ja\/pfas-analysis-by-u-s-fda-c-010-03-for-food-and-feed-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4292-ja\/pfas-analysis-by-u-s-fda-c-010-03-for-food-and-feed-japan\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4298-ja\/pfas-analysis-by-din-en-17892-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4298-ja\/pfas-analysis-by-din-en-17892-for-drinking-water-japan\"><strong>DIN EN 17892<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4299-ja\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4299-ja\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge-japan\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4300-ja\/pfas-analysis-by-iso-21675-2019-for-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4300-ja\/pfas-analysis-by-iso-21675-2019-for-water-japan\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4301-ja\/pfas-analysis-by-iso-23702-1-2023-for-leather-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4301-ja\/pfas-analysis-by-iso-23702-1-2023-for-leather-japan\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4303-ja\/pfas-analysis-by-astm-d7968-23-for-soil-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4303-ja\/pfas-analysis-by-astm-d7968-23-for-soil-japan\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4304-ja\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4304-ja\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater-japan\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4305-ja\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4305-ja\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples-japan\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td colspan=\"17\"><strong><strong>\u5206\u6790\u524d\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u307e\u305f\u306f\u5fae\u7c92\u5b50\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u306e\u30d5\u30a3\u30eb\u30bf\u51e6\u7406<\/strong><\/strong><\/td><\/tr><tr><td rowspan=\"3\">\u30b7\u30ea\u30f3\u30b8<br>\u30d5\u30a3\u30eb\u30bf<\/td><td>30 mm syringe filter: 0.45 \u00b5m, nylon (<a href=\"https:\/\/www.restek.com\/p\/23981\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 23981<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>30 mm syringe filter: 0.22 \u00b5m, nylon (<a href=\"https:\/\/www.restek.com\/p\/23980\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 23980<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>25 mm syringe filter: 0.22 \u00b5m, polypropylene (<a href=\"https:\/\/www.restek.com\/p\/28935\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28935<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u30ac\u30e9\u30b9\u30a6\u30fc\u30eb<\/td><td>Deactivated borosilicate glass wool (<a href=\"https:\/\/www.restek.com\/p\/20789\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 20789<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td colspan=\"16\"><em>\u30d5\u30a3\u30eb\u30bf\u30fc\u30d0\u30a4\u30a2\u30eb\u306e\u6750\u8cea\u3084\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\u306b\u3064\u3044\u3066\u306f <a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1337?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002<\/a><\/em><\/td><\/tr><tr><td colspan=\"17\"><strong><strong>\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\uff08\u62bd\u51fa\u542b\u3080\uff09<\/strong><\/strong><\/td><\/tr><tr><td rowspan=\"5\">SPE (WAX)<\/td><td>Resprep PFAS SPE cartridge: 6 mL, WAX 150 mg\/GCB 50 mg (<a href=\"https:\/\/www.restek.com\/p\/28930\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28930<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep PFAS SPE cartridge with filter aid: 6 mL, filter aid 2000 mg\/WAX 150 mg\/GCB 50 mg (<a href=\"https:\/\/www.restek.com\/p\/28931\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28931<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep polymeric SPE cartridge: WAX, 6 mL\/500 mg, 30 \u00b5m (<a href=\"https:\/\/www.restek.com\/p\/28268\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28268<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep polymeric SPE cartridge: WAX, 6 mL\/200 mg, 30 \u00b5m (<a href=\"https:\/\/www.restek.com\/p\/28292\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28292<\/a>)<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td colspan=\"16\"><em><em>WAX SPE\u306e\u4ed6\u306e\u69cb\u6210\u306b\u3064\u3044\u3066\u306f<a href=\"https:\/\/www.restek.com\/global\/ja\/c\/sp-pfas?Ns=restekProduct.x_productBadge%7C0\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089\u3092\u3054\u53c2\u7167\u4e0b\u3055\u3044\u3002<\/a><\/em><\/em><\/td><\/tr><tr><td>SPE (S-DVB)<\/td><td>Resprep S-DVB SPE cartridge: 6 mL\/500 mg (<a href=\"https:\/\/www.restek.com\/p\/28937\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28937<\/a>)<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td><strong>*<\/strong><\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u88fd\u3000sample reservoir<\/td><td>Polypropylene sample reservoir: 75 mL (<a href=\"https:\/\/www.restek.com\/p\/26015\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 26015<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u88fd connectors<\/td><td>Polypropylene connectors (<a href=\"https:\/\/www.restek.com\/p\/26007\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 26007<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td rowspan=\"2\">QuEChERS \u62bd\u51fa\u5869<\/td><td>Q-sep QuEChERS extraction salt packets only, unbuffered FDA method: 6 g MgSO4, 1.5 g NaCl (<a href=\"https:\/\/www.restek.com\/p\/28898\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28898<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td colspan=\"16\"><em><em>\u4ed6\u306eQuEChERS\u88fd\u54c1\u306b\u3064\u3044\u3066\u306f<a href=\"https:\/\/www.restek.com\/global\/ja\/search\/_\/N-7864648?Ntt=quechers&amp;Ns=bestMatch\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089\u3092\u3054\u53c2\u7167\u4e0b\u3055\u3044\u3002<\/a><\/em><\/em><\/td><\/tr><tr><td>\u30ec\u30b8\u30f3<\/td><td>Clean SDVB resin (<a href=\"https:\/\/www.restek.com\/p\/24230\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 24230<\/a>)<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td rowspan=\"2\">\u30d0\u30ad\u30e5\u30fc\u30e0<br>\u30de\u30cb\u30db\u30fc\u30eb\u30c9<\/td><td>Resprep QR-24 vacuum manifold (<a href=\"https:\/\/www.restek.com\/p\/28299-VM\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28299-VM<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Resprep QR-12 vacuum manifold (<a href=\"https:\/\/www.restek.com\/p\/28298-VM\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28298-VM<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td rowspan=\"2\">\u771f\u7a7a\u30dd\u30f3\u30d7<\/td><td>Chemker 300 PTFE vacuum pump: 20 L\/min, AC110 V, 60 Hz (<a href=\"https:\/\/www.restek.com\/p\/27426\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 27426<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>*<\/strong><\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><tr><td>Chemker 300 PTFE vacuum pump: 18 L\/min, AC220 V, 50 Hz (<a href=\"https:\/\/www.restek.com\/p\/27427\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 27427<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>*<\/strong><\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>&#8211;<\/td><td>&#8211;<\/td><td>&#8211;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6ce8:<\/strong> \u4e0a\u8a18\u306e\u88fd\u54c1\u306e\u3046\u3061\u306e\u3044\u304f\u3064\u304b\u306f\u3001\u5404\u30e1\u30bd\u30c3\u30c9\u306e\u88fd\u54c1\u8aac\u660e\u3068\u6b63\u78ba\u306b\u306f\u4e00\u81f4\u3057\u3066\u3044\u306a\u3044\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<br><strong>*<\/strong> \u3053\u306eCDC\u30e1\u30bd\u30c3\u30c9\u306f\u3001C8\u307e\u305f\u306fC18 SPE\u6750\u6599\u3092\u4f7f\u7528\u3057\u305f\u3001\u81ea\u52d5\u5316\u3055\u308c\u305f\u30aa\u30f3\u30e9\u30a4\u30f3SPE\u306b\u57fa\u3065\u3044\u3066\u3044\u307e\u3059\u3002\u4e0a\u8a18\u306e\u88fd\u54c1\u306f\u3001\u30aa\u30d5\u30e9\u30a4\u30f3SPE\u306b\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<br><sup>\u2020<\/sup> \u3053\u306e\u7c73\u56fdFDA\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001\u30ad\u30e3\u30c3\u30d7\u306a\u3057\u306e\u30ca\u30ce\u30d5\u30a3\u30eb\u30bf\u30fc\u30d0\u30a4\u30a2\u30eb\u3092\u4f7f\u7528\u3057\u307e\u3059\u3002 \u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30ad\u30e3\u30c3\u30d7 (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23244\" target=\"_blank\" rel=\"noreferrer noopener\">23244 <\/a>\u304a\u3088\u3073cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23247\" target=\"_blank\" rel=\"noreferrer noopener\">23247<\/a>)\u306f\u5225\u9014\u6ce8\u6587\u3067\u304d\u307e\u3059\u3002<br><strong>X<\/strong> \u3053\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001\u518d\u751f\u30bb\u30eb\u30ed\u30fc\u30b9\u30d5\u30a3\u30eb\u30bf\u30fc\u306e\u63a1\u7528\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30ca\u30a4\u30ed\u30f3\u3068\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306fPFAS\u5206\u6790\u7528\u3067\u591a\u304f\u63a1\u7528\u3055\u308c\u3066\u3044\u308b\u30d5\u30a3\u30eb\u30bf\u30fc\u30e1\u30f3\u30d6\u30ec\u30f3\u6750\u6599\u3067\u3059\u3002<br><strong>X<\/strong> \u3053\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u3001\u30ac\u30e9\u30b9\u7e4a\u7dad\u30d5\u30a3\u30eb\u30bf\u30fc\u306e\u63a1\u7528\u304c\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u30ca\u30a4\u30ed\u30f3\u3068\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\u306fPFAS\u5206\u6790\u7528\u3067\u591a\u304f\u63a1\u7528\u3055\u308c\u3066\u3044\u308b\u30d5\u30a3\u30eb\u30bf\u30fc\u30e1\u30f3\u30d6\u30ec\u30f3\u6750\u6599\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"height:55px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u4e00\u822c\u7684\u306a\u30e9\u30dc\u7528\u54c1<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4284-ja\/pfas-analysis-by-u-s-epa-method-537-1-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4284-ja\/pfas-analysis-by-u-s-epa-method-537-1-for-drinking-water-japan\"><strong>EPA 537.1<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles\/evar4285-ja\/pfas-analysis-by-u-s-epa-method-533-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4285-ja\/pfas-analysis-by-u-s-epa-method-533-for-drinking-water-japan\"><strong>EPA 533<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4286-ja\/pfas-analysis-by-u-s-epa-method-16-for-aqueous-solid-biosolids-and-tissue-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4286-ja\/pfas-analysis-by-u-s-epa-method-16-for-aqueous-solid-biosolids-and-tissue-japan\"><strong>EPA 1633A<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles\/evar4287-ja\/pfas-analysis-by-u-s-epa-method-otm-45-for-emissions\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4287-ja\/pfas-analysis-by-u-s-epa-method-otm-45-for-emissions\"><strong>EPA OTM 45<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4289-ja\/pfas-analysis-by-u-s-epa-method-8327-for-surface-water-groundwater-and-wastewater\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4289-ja\/pfas-analysis-by-u-s-epa-method-8327-for-surface-water-groundwater-and-wastewater\"><strong>EPA 8327<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4290-ja\/pfas-analysis-by-u-s-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4290-ja\/pfas-analysis-by-u-s-usda-clg-pfas-2-04-for-bovine-porcine-poultry-siluriformes-muscle-and-bovine-plasma-japan\"><strong>USDA CLG-PFAS 2.04&nbsp;&nbsp;<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/cfar4291-ja\/pfas-analysis-by-cdc-6304-09-for-serum-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/cfar4291-ja\/pfas-analysis-by-cdc-6304-09-for-serum-japan\"><strong>CDC 6304.09<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4292-ja\/pfas-analysis-by-u-s-fda-c-010-03-for-food-and-feed-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/fsar4292-ja\/pfas-analysis-by-u-s-fda-c-010-03-for-food-and-feed-japan\"><strong>US FDA C-010.03<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4298-ja\/pfas-analysis-by-din-en-17892-for-drinking-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4298-ja\/pfas-analysis-by-din-en-17892-for-drinking-water-japan\"><strong>DIN EN 17892<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4299-ja\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4299-ja\/pfas-analysis-by-din-38407-42-for-water-wastewater-and-sludge-japan\"><strong>DIN 38407-42<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4300-ja\/pfas-analysis-by-iso-21675-2019-for-water-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4300-ja\/pfas-analysis-by-iso-21675-2019-for-water-japan\"><strong>ISO 21675:2019<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4301-ja\/pfas-analysis-by-iso-23702-1-2023-for-leather-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnar4301-ja\/pfas-analysis-by-iso-23702-1-2023-for-leather-japan\"><strong>ISO 23702-1:2023<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4303-ja\/pfas-analysis-by-astm-d7968-23-for-soil-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4303-ja\/pfas-analysis-by-astm-d7968-23-for-soil-japan\"><strong>ASTM D7968-23<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4304-ja\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4304-ja\/pfas-analysis-by-astm-d7979-20-for-water-sludge-influent-effluent-and-wastewater-japan\"><strong>ASTM D7979-20<\/strong><\/a><\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4305-ja\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4305-ja\/pfas-analysis-by-astm-d8421-22-for-aqueous-samples-japan\"><strong>ASTM D8421-22<\/strong><\/a><\/td><\/tr><tr><td>\u30d0\u30a4\u30a2\u30eb&nbsp;Polypropylene vials: 100-pk.(<a href=\"https:\/\/www.restek.com\/p\/23243\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 23243<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u30d0\u30a4\u30a2\u30eb&nbsp;Polypropylene vials: 1000-pk.(<a href=\"https:\/\/www.restek.com\/p\/23246\" target=\"_blank\" rel=\"noopener\">cat.# 23246<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u30d0\u30a4\u30a2\u30eb\u30ad\u30e3\u30c3\u30d7&nbsp;Polyethylene vial caps: 100-pk.(<a href=\"https:\/\/www.restek.com\/p\/23244\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 23244<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u30d0\u30a4\u30a2\u30eb\u30ad\u30e3\u30c3\u30d7&nbsp;Polyethylene vial caps: 1000-pk. (<a href=\"https:\/\/www.restek.com\/p\/23247\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 23247<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6&nbsp;Centrifuge tubes: 50 mL, 50-pk. (<a href=\"https:\/\/www.restek.com\/p\/25846\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 25846<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u9060\u5fc3\u30c1\u30e5\u30fc\u30d6&nbsp;Centrifuge tubes: 50 mL, 500-pk. (<a href=\"https:\/\/www.restek.com\/p\/28290\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 28290<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><\/tr><tr><td>\u30b7\u30ea\u30f3\u30b8&nbsp;Norm-Ject plastic syringe: 10 mL Luer Lock tip (<a href=\"https:\/\/www.restek.com\/p\/22775\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 22775<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><\/tr><tr><td>\u30b7\u30ea\u30f3\u30b8&nbsp;Norm-Ject plastic syringe: 5 mL Luer Lock tip (<a href=\"https:\/\/www.restek.com\/p\/22774\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 22774<\/a>)<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td>X<\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><td><strong>X<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6ce8:<\/strong> \u4e0a\u8a18\u306e\u88fd\u54c1\u306e\u3046\u3061\u306e\u3044\u304f\u3064\u304b\u306f\u3001\u5404\u30e1\u30bd\u30c3\u30c9\u306e\u88fd\u54c1\u8aac\u660e\u3068\u6b63\u78ba\u306b\u306f\u4e00\u81f4\u3057\u3066\u3044\u306a\u3044\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002<br><strong>X<\/strong> ASTM\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u30ac\u30e9\u30b9\u30b7\u30ea\u30f3\u30b8\u3092\u4f7f\u7528\u3059\u308b\u3068\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002Norm-Ject plastic syringe\u306f\u30dd\u30ea\u30d7\u30ed\u30d4\u30ec\u30f3\uff0f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u88fd\u3067\u3042\u308a\u3001\u4ee3\u66ff\u54c1\u3068\u3057\u3066\u4f7f\u7528\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:55px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u7c73\u56fdEPA OTM-50 (GC-MS)\u306b\u3088\u308b\u63ee\u767a\u6027\u30d5\u30c3\u7d20\u5316\u5408\u7269\uff08VFC\uff09\u5206\u6790\u7528\u3078\u306e\u63a8\u5968\u88fd\u54c1<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4331-ja\/vfc-analysis-by-u-s-epa-method-otm-50-for-emissions-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar4331-ja\/vfc-analysis-by-u-s-epa-method-otm-50-for-emissions-japan\"><strong>EPA OTM-50<\/strong><\/a><\/td><\/tr><tr><td colspan=\"2\"><strong><strong>\u30b5\u30f3\u30d7\u30eb\u53ce\u96c6\uff0f\u8f38\u9001\uff08\u30a8\u30a2\u30ad\u30e3\u30cb\u30b9\u30bf\uff09<\/strong><\/strong><\/td><\/tr><tr><td>SilcoCan Air Sampling Canister, 6 L, with 3-Port Siltek-Treated RAVE+ Valve with Gauge (<a href=\"https:\/\/www.restek.com\/p\/27309\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 27309<\/a>)<\/td><td>X<\/td><\/tr><tr><td>SilcoCan Air Sampling Canister, 6 L, with 2-Port Siltek-Treated RAVE+ Valve (<a href=\"https:\/\/www.restek.com\/p\/27307\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 27307<\/a>)<\/td><td>X<\/td><\/tr><tr><td>SilcoCan Air Sampling Canister, 6 L, No Valve (<a href=\"https:\/\/www.restek.com\/p\/22092\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 22092<\/a>)<\/td><td>X<\/td><\/tr><tr><td>TO-Can Air Sampling Canister, 6 L, with 3-Port RAVE+ Valve with Gauge (<a href=\"https:\/\/www.restek.com\/p\/27319\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 27319<\/a>)<\/td><td>X<\/td><\/tr><tr><td>TO-Can Air Sampling Canister, 6 L, with 2-Port RAVE+ Valve (<a href=\"https:\/\/www.restek.com\/p\/27318\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 27318<\/a>)<\/td><td>X<\/td><\/tr><tr><td>TO-Can Air Sampling Canister, 6 L, No Valve (<a href=\"https:\/\/www.restek.com\/p\/22096\" target=\"_blank\" rel=\"noreferrer noopener\">cat.# 22096<\/a>)<\/td><td>X<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Restek Corporation, Guide to PFAS testing methods, a global survey of PFAS testing methods and guidelines, Technical article, &nbsp;EVAR3552C-UNV, 2024. <a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/evar3552-ja\/guide-to-pfas-testing-methods-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/EVAR3552-JA\/guide-to-pfas-testing-methods-japan\">https:\/\/www.restek.com\/articles\/guide-to-pfas-testing-methods<\/a><\/li>\n\n\n\n<li>S.H., Liang, J. A. Steimling, ,M. Chang Analysis of ultrashort-chain and short-chain (C1 to C4) per- and polyfluorinated substances in potable and non-potable waters. J. Chromatogr. Open 4 (100098) (2023) <a href=\"https:\/\/doi.org\/10.1016\/j.jcoa.2023.100098\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.jcoa.2023.100098<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 537.1, Determination of selected per- and polyfluorinated alkyl substances in drinking water by solid phase extraction and liquid chromatography\/tandem mass spectrometry (LC\/MS\/MS), November 2018. <a href=\"https:\/\/cfpub.epa.gov\/si\/si_public_file_download.cfm?p_download_id=537290&amp;Lab=NERL\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/cfpub.epa.gov\/si\/si_public_file_download.cfm?p_download_id=537290&amp;Lab=NERL<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 533, Determination of per- and polyfluoroalkyl substances in drinking water by isotope dilution anion exchange solid phase extraction and liquid chromatography\/tandem mass spectrometry, November 2019. <a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2019-12\/documents\/method-533-815b19020.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2019-12\/documents\/method-533-815b19020.pdf<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 1633, Revision A, Analysis of per- and polyfluoroalkyl substances (pfas) in aqueous, solid, biosolids, and tissue samples by LC-MS\/MS, December 2024.&nbsp;<a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2024-12\/method-1633a-december-5-2024-508-compliant.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">www.epa.gov\/system\/files\/documents\/2024-12\/method-1633a-december-5-2024-508-compliant.pdf<\/a>&nbsp;<\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, Other Test Method-45 (OTM-45), Measurement of selected per- and polyfluorinated alkyl substances from stationary sources, January 13, 2021. <a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, EPA Method 8327, Per- and polyfluoroalkyl substances (PFAS) by liquid chromatography\/tandem mass spectrometry (LC\/MS\/MS), July 2021. <a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2021-07\/8327.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/system\/files\/documents\/2021-07\/8327.pdf<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Department of Agriculture, Food Safety and Inspection Service, Chemistry Laboratory Guidebook, CLG-PFAS 2.04, Screening, determination, and confirmation of PFAS by UHPLC-MS-MS, February 28, 2023. <a href=\"https:\/\/www.fsis.usda.gov\/sites\/default\/files\/media_file\/documents\/CLG-PFAS2.04.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.fsis.usda.gov\/sites\/default\/files\/media_file\/documents\/CLG-PFAS2.04.pdf<\/a> &nbsp;<\/li>\n\n\n\n<li>U.S. Centers for Disease Control and Prevention,&nbsp;CDC 6304.09, Perfluoroalkyl and polyfluoroalkyl substances, February 2019. <a href=\"https:\/\/wwwn.cdc.gov\/nchs\/data\/nhanes\/public\/2019\/labmethods\/PFAS-K-Met-508.pdf%20\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/wwwn.cdc.gov\/nchs\/data\/nhanes\/public\/2019\/labmethods\/PFAS-K-Met-508.pdf&nbsp;<\/a><\/li>\n\n\n\n<li>U.S. Food and Drug Administration, FDA C-010.02, Determination of 30 per and polyfluoroalkyl substances (PFAS) in food and feed using liquid chromatography-tandem mass spectrometry (LC-MS\/MS), April 12, 2024. <a href=\"https:\/\/www.fda.gov\/media\/131510\/download\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.fda.gov\/media\/131510\/download<\/a> &nbsp;&nbsp;<\/li>\n\n\n\n<li>DIN EN 17892, Water quality-Determination of the sum of perfluorinated substances (Sum of PFAS) in drinking water &#8211; Method using liquid chromatography\/mass spectrometry (LC\/MS), September 2021.<\/li>\n\n\n\n<li>DIN 38407-42, German standard methods for the examination of water, waste water and sludge-Jointly determinable substances (group F)-Part 42: determination of selected polyfluorinated compounds (PFC) in water-Method using high performance liquid chromatography and mass spectrometric detection (HPLC\/MS-MS)after solid-liquid extraction (F 42), March 2011.<\/li>\n\n\n\n<li>ISO 21675:2019, Water quality\u2014Determination of perfluoroalkyl and polyfluoroalkyl substances (PFAS) in water\u2014Method using solid phase extraction and liquid chromatography-tandem mass spectrometry (LC-MS\/MS), 2019. <a href=\"https:\/\/www.iso.org\/standard\/71338.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.iso.org\/standard\/71338.html<\/a><\/li>\n\n\n\n<li>ASTM D7968-23, Standard test method for determination of polyfluorinated compounds in soil by liquid chromatography tandem mass spectrometry (LC\/MS\/MS), November 6, 2023.<br>&nbsp;<a href=\"https:\/\/www.astm.org\/d7968-23.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.astm.org\/d7968-23.html<\/a> &nbsp;<\/li>\n\n\n\n<li>ASTM D7979-20, Standard test method for determination of per- and polyfluoroalkyl substances in water, sludge, influent, effluent, and wastewater by liquid chromatography tandem mass spectrometry (LC\/MS\/MS), September 3, 2020. <a href=\"https:\/\/www.astm.org\/d7979-20.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.astm.org\/d7979-20.html<\/a> &nbsp;<\/li>\n\n\n\n<li>ASTM D8421-22, Standard test method for determination of per- and polyfluoroalkyl substances (PFAS) in aqueous matrices by co-solvation followed by liquid chromatography tandem mass spectrometry (LC\/MS\/MS) <a href=\"https:\/\/www.astm.org\/d8421-22.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.astm.org\/d8421-22.html<\/a><\/li>\n\n\n\n<li>U.S. Environmental Protection Agency, Other Test Method-50, OTM-50, Sampling and analysis of volatile fluorinated compounds from stationary sources using passivated stainless-steel canisters, January 2025. <a href=\"https:\/\/www.epa.gov\/system\/files\/documents\/2025-01\/otm-50-release-1-r1.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/system\/files\/documents\/2025-01\/otm-50-release-1-r1.pdf<\/a><\/li>\n<\/ol>\n\n\n\n<div style=\"height:25px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group hub-fullwidth-container has-theme-palette-9-background-color has-background\" style=\"margin-top:0px;margin-bottom:0px;padding-top:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\"><style>.kadence-column60395_a09de0-04 > .kt-inside-inner-col{padding-top:45px;padding-right:0px;padding-bottom:45px;padding-left:0px;}.kadence-column60395_a09de0-04 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column60395_a09de0-04 > .kt-inside-inner-col{flex-direction:column;}.kadence-column60395_a09de0-04 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column60395_a09de0-04 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column60395_a09de0-04{position:relative;}@media all and (max-width: 1024px){.kadence-column60395_a09de0-04 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column60395_a09de0-04 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column60395_a09de0-04 hub-guttered-centered-container\"><div class=\"kt-inside-inner-col\"><style>.kb-row-layout-id60395_61094f-cc > .kt-row-column-wrap{align-content:start;}:where(.kb-row-layout-id60395_61094f-cc > .kt-row-column-wrap) > .wp-block-kadence-column{justify-content:start;}.kb-row-layout-id60395_61094f-cc > .kt-row-column-wrap{column-gap:var(--global-kb-gap-md, 2rem);row-gap:var(--global-kb-gap-md, 2rem);padding-top:20px;padding-right:20px;padding-bottom:20px;padding-left:20px;grid-template-columns:minmax(0, 1fr);}.kb-row-layout-id60395_61094f-cc{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;overflow:clip;isolation:isolate;}.kb-row-layout-id60395_61094f-cc > .kt-row-layout-overlay{border-top-left-radius:16px;border-top-right-radius:16px;border-bottom-right-radius:16px;border-bottom-left-radius:16px;}.kb-row-layout-id60395_61094f-cc > .kt-row-layout-overlay{opacity:0.30;}@media all and (max-width: 1024px){.kb-row-layout-id60395_61094f-cc > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}@media all and (max-width: 767px){.kb-row-layout-id60395_61094f-cc > .kt-row-column-wrap{grid-template-columns:minmax(0, 1fr);}}<\/style><div class=\"kb-row-layout-wrap kb-row-layout-id60395_61094f-cc alignnone wp-block-kadence-rowlayout\"><div class=\"kt-row-column-wrap kt-has-1-columns kt-row-layout-equal kt-tab-layout-inherit kt-mobile-layout-row kt-row-valign-top\">\n<style>.kadence-column60395_09f2ad-a4 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column60395_09f2ad-a4 > .kt-inside-inner-col{flex-direction:column;}.kadence-column60395_09f2ad-a4 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column60395_09f2ad-a4 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column60395_09f2ad-a4{position:relative;}@media all and (max-width: 1024px){.kadence-column60395_09f2ad-a4 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column60395_09f2ad-a4 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column60395_09f2ad-a4\"><div class=\"kt-inside-inner-col\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png\" alt=\"Icon depicting customer service person.\" class=\"wp-image-95744\" style=\"width:100px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-1024x1024.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-300x300.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic-768x768.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-gnlp4243-pfas-hub-contact-an-expert-leaf-graphic.png 1200w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<style>.wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23, .wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23[data-kb-block=\"kb-adv-heading60395_489e09-23\"]{margin-top:20px;text-align:center;font-size:48px;line-height:55px;font-weight:400;font-style:normal;font-family:'Open Sans';}.wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23, .wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23[data-kb-block=\"kb-adv-heading60395_489e09-23\"] .kb-adv-text-inner{background-image:linear-gradient(270deg,rgb(4,137,214) 0%,rgb(1,94,155) 100%);background-clip:text;-webkit-box-decoration-break:clone;box-decoration-break:clone;-webkit-background-clip:text;-webkit-text-fill-color:transparent;}.wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23 mark.kt-highlight, .wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23[data-kb-block=\"kb-adv-heading60395_489e09-23\"] mark.kt-highlight{font-style:normal;-webkit-text-fill-color:initial !important;-webkit-background-clip:initial !important;background-clip:initial !important;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}.wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23 img.kb-inline-image, .wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23[data-kb-block=\"kb-adv-heading60395_489e09-23\"] img.kb-inline-image{width:150px;vertical-align:baseline;}@media all and (max-width: 1024px){.wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23, .wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23[data-kb-block=\"kb-adv-heading60395_489e09-23\"]{font-size:40px;}}@media all and (max-width: 767px){.wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23, .wp-block-kadence-advancedheading.kt-adv-heading60395_489e09-23[data-kb-block=\"kb-adv-heading60395_489e09-23\"]{font-size:36px;}}<\/style><h2 class=\"kt-adv-heading60395_489e09-23 wp-block-kadence-advancedheading\" data-kb-block=\"kb-adv-heading60395_489e09-23\"><span class=\"kb-adv-text-inner\">PFAS\u5206\u6790\u3067\u304a\u56f0\u308a\u3054\u3068\u306f\u3042\u308a\u307e\u305b\u3093\u304b\uff1f<\/span><\/h2>\n\n\n<p class=\"has-text-align-center has-17-font-size has-theme-palette-3-color has-text-color has-link-color wp-elements-1 wp-block-paragraph\" style=\"padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:23px\">\u30e1\u30bd\u30c3\u30c9\u9078\u5b9a\u304b\u3089\u88fd\u54c1\u9078\u3073\u307e\u3067\u3001PFAS\u5c02\u9580\u30c1\u30fc\u30e0\u304c\u3054\u76f8\u8ac7\u3092\u627f\u308a\u307e\u3059\u3002\u8907\u96d1\u306a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u4e00\u7dd2\u306b\u6574\u7406\u3057\u3001\u7cbe\u5ea6\u3068\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u5206\u6790\u7d50\u679c\u306b\u3064\u306a\u3052\u307e\u3059\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns60395_c6c21a-25{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns60395_c6c21a-25 .kt-button{font-weight:normal;font-style:normal;}.kt-btns60395_c6c21a-25 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns60395_c6c21a-25 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns60395_c6c21a-25 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns60395_c6c21a-25 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns60395_c6c21a-25 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns60395_c6c21a-25 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns60395_c6c21a-25 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns60395_c6c21a-25\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;font-size:var(--global-kb-font-size-md, 1.25rem);border-top-left-radius:10px;border-top-right-radius:10px;border-bottom-right-radius:10px;border-bottom-left-radius:10px;border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.kb-btn60395_024141-9a.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn60395_024141-9a.kb-button:hover .kb-svg-icon-wrap, .kb-btn60395_024141-9a.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button:focus{color:#61b522;background:var(--global-palette9, #ffffff);border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}.wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn60395_024141-9a.kb-button:focus{border-top:2px solid #61b522;border-right:2px solid #61b522;border-bottom:2px solid #61b522;border-left:2px solid #61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn60395_024141-9a kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/explore.restek.com\/PFAS_ja\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\"><strong>PFAS\u5c02\u9580\u30c1\u30fc\u30e0\u306b\u30a2\u30af\u30bb\u30b9<\/strong><\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n<\/div><\/div><\/div><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column60395_93027a-0b > .kt-inside-inner-col{display:flex;}.kadence-column60395_93027a-0b{max-width:650px;margin-left:auto;margin-right:auto;}.wp-block-kadence-column.kb-section-dir-horizontal:not(.kb-section-md-dir-vertical)>.kt-inside-inner-col>.kadence-column60395_93027a-0b{-webkit-flex:0 1 650px;flex:0 1 650px;max-width:unset;margin-left:unset;margin-right:unset;}.kadence-column60395_93027a-0b > .kt-inside-inner-col{padding-top:var(--global-kb-spacing-md, 2rem);padding-right:var(--global-kb-spacing-md, 2rem);padding-bottom:var(--global-kb-spacing-md, 2rem);padding-left:var(--global-kb-spacing-md, 2rem);}.kadence-column60395_93027a-0b > .kt-inside-inner-col,.kadence-column60395_93027a-0b > .kt-inside-inner-col:before{border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-right-radius:8px;border-bottom-left-radius:8px;}.kadence-column60395_93027a-0b > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column60395_93027a-0b > .kt-inside-inner-col{flex-direction:row;flex-wrap:wrap;align-items:center;}.kadence-column60395_93027a-0b > .kt-inside-inner-col > *, .kadence-column60395_93027a-0b > .kt-inside-inner-col > figure.wp-block-image, .kadence-column60395_93027a-0b > .kt-inside-inner-col > figure.wp-block-kadence-image{margin-top:0px;margin-bottom:0px;}.kadence-column60395_93027a-0b > .kt-inside-inner-col > .kb-image-is-ratio-size{flex-grow:1;}.kadence-column60395_93027a-0b > .kt-inside-inner-col{background-image:url('https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-background-texture.jpg');background-size:cover;background-position:center center;background-attachment:scroll;background-repeat:no-repeat;}.kadence-column60395_93027a-0b > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column60395_93027a-0b{position:relative;}@media all and (min-width: 1025px){.wp-block-kadence-column.kb-section-dir-horizontal>.kt-inside-inner-col>.kadence-column60395_93027a-0b{-webkit-flex:0 1 650px;flex:0 1 650px;max-width:unset;margin-left:unset;margin-right:unset;}}@media all and (max-width: 1024px){.kadence-column60395_93027a-0b > .kt-inside-inner-col{flex-direction:row;flex-wrap:wrap;align-items:center;}}@media all and (min-width: 768px) and (max-width: 1024px){.kadence-column60395_93027a-0b > .kt-inside-inner-col > *, .kadence-column60395_93027a-0b > .kt-inside-inner-col > figure.wp-block-image, .kadence-column60395_93027a-0b > .kt-inside-inner-col > figure.wp-block-kadence-image{margin-top:0px;margin-bottom:0px;}.kadence-column60395_93027a-0b > .kt-inside-inner-col > .kb-image-is-ratio-size{flex-grow:1;}}@media all and (max-width: 767px){.wp-block-kadence-column.kb-section-sm-dir-vertical:not(.kb-section-sm-dir-horizontal):not(.kb-section-sm-dir-specificity)>.kt-inside-inner-col>.kadence-column60395_93027a-0b{max-width:650px;-webkit-flex:1;flex:1;margin-left:auto;margin-right:auto;}.kadence-column60395_93027a-0b > .kt-inside-inner-col{flex-direction:row;flex-wrap:wrap;justify-content:flex-start;}.kadence-column60395_93027a-0b > .kt-inside-inner-col > *, .kadence-column60395_93027a-0b > .kt-inside-inner-col > figure.wp-block-image, .kadence-column60395_93027a-0b > .kt-inside-inner-col > figure.wp-block-kadence-image{margin-top:0px;margin-bottom:0px;}.kadence-column60395_93027a-0b > .kt-inside-inner-col > .kb-image-is-ratio-size{flex-grow:1;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column60395_93027a-0b kb-section-dir-horizontal\"><div class=\"kt-inside-inner-col\"><style>.kadence-column60395_35045f-76 > .kt-inside-inner-col{display:flex;}.kadence-column60395_35045f-76 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column60395_35045f-76 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60395_35045f-76 > .kt-inside-inner-col > .aligncenter{width:100%;}.kt-row-column-wrap > .kadence-column60395_35045f-76{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_35045f-76{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_35045f-76 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60395_35045f-76 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column60395_35045f-76{position:relative;}@media all and (max-width: 1024px){.kt-row-column-wrap > .kadence-column60395_35045f-76{align-self:center;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_35045f-76{align-self:auto;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_35045f-76 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 1024px){.kadence-column60395_35045f-76 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kt-row-column-wrap > .kadence-column60395_35045f-76{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_35045f-76{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_35045f-76 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60395_35045f-76 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column60395_35045f-76\"><div class=\"kt-inside-inner-col\">\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-2 wp-block-paragraph\" style=\"margin-top:0px;margin-bottom:0px;padding-top:0;padding-right:0;padding-bottom:0;padding-left:0;font-size:22px\"><strong>PFAS\u5206\u6790\u3092\u30b7\u30f3\u30d7\u30eb\u306b<\/strong><\/p>\n\n\n\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-3 wp-block-paragraph\">\u88fd\u54c1\u9078\u5b9a\u304b\u3089\u30a8\u30ad\u30b9\u30d1\u30fc\u30c8\u306b\u3088\u308b\u30ac\u30a4\u30c9\u307e\u3067\u3002\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u306b\u5fc5\u8981\u306a\u60c5\u5831\u3092\u3001\u3072\u3068\u3064\u306b\u307e\u3068\u3081\u307e\u3057\u305f\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kb-btns60395_8c1cbe-7c{gap:var(--global-kb-gap-xs, 0.5rem );justify-content:center;align-items:center;}.kt-btns60395_8c1cbe-7c .kt-button{font-weight:normal;font-style:normal;}.kt-btns60395_8c1cbe-7c .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns60395_8c1cbe-7c .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns60395_8c1cbe-7c .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns60395_8c1cbe-7c .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns60395_8c1cbe-7c .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns60395_8c1cbe-7c .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns60395_8c1cbe-7c .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns60395_8c1cbe-7c\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn60395_df0e86-20.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn60395_df0e86-20.kb-button{color:var(--global-palette9, #ffffff);background:#61b522;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-right-radius:8px;border-bottom-left-radius:8px;border-top-color:#61b522;border-right-color:#61b522;border-bottom-color:#61b522;border-left-color:#61b522;margin-right:var(--global-kb-spacing-xs, 1rem);}.wp-block-kadence-advancedbtn .kb-btn60395_df0e86-20.kb-button:not(.specificity):not(.extra-specificity){text-decoration:none;}.kb-btn60395_df0e86-20.kb-button .kb-svg-icon-wrap{color:var(--global-palette9, #ffffff);}.kb-btn60395_df0e86-20.kb-button:hover .kb-svg-icon-wrap, .kb-btn60395_df0e86-20.kb-button:focus .kb-svg-icon-wrap{color:#61b522;}.wp-block-kadence-advancedbtn .kb-btn60395_df0e86-20.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn60395_df0e86-20.kb-button:focus{color:#61b522;background:#0d507d;}@media all and (max-width: 1024px){.wp-block-kadence-advancedbtn .kb-btn60395_df0e86-20.kb-button{border-top-color:#61b522;border-right-color:#61b522;border-bottom-color:#61b522;border-left-color:#61b522;}}@media all and (max-width: 767px){.wp-block-kadence-advancedbtn .kb-btn60395_df0e86-20.kb-button{border-top-color:#61b522;border-right-color:#61b522;border-bottom-color:#61b522;border-left-color:#61b522;}}<\/style><a class=\"kb-button kt-button button kb-btn60395_df0e86-20 kt-btn-size-standard kt-btn-width-type-auto kb-btn-global-outline kt-btn-has-text-true kt-btn-has-svg-true wp-block-kadence-singlebtn kb-preset--outline\" href=\"https:\/\/discover.restek.com\/pfas-analysis\/\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\"><strong>PFAS<\/strong>\u5206\u6790\u306e\u30d1\u30fc\u30c8\u30ca\u30fc\u3078<\/span><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_arrowRight kt-btn-icon-side-right\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><line x1=\"5\" y1=\"12\" x2=\"19\" y2=\"12\"\/><polyline points=\"12 5 19 12 12 19\"\/><\/svg><\/span><\/a><\/div>\n<\/div><\/div>\n\n\n<style>.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col{display:flex;}.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col > .aligncenter{width:100%;}.kt-row-column-wrap > .kadence-column60395_a2d2e7-cd{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_a2d2e7-cd{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column60395_a2d2e7-cd{position:relative;}@media all and (max-width: 1024px){.kt-row-column-wrap > .kadence-column60395_a2d2e7-cd{align-self:center;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_a2d2e7-cd{align-self:auto;}}@media all and (max-width: 1024px){.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 1024px){.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kt-row-column-wrap > .kadence-column60395_a2d2e7-cd{align-self:center;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_a2d2e7-cd{align-self:auto;}.kt-inner-column-height-full:not(.kt-has-1-columns) > .wp-block-kadence-column.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}.kadence-column60395_a2d2e7-cd > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column60395_a2d2e7-cd\"><div class=\"kt-inside-inner-col\">\n<figure class=\"wp-block-image size-large has-custom-border\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"683\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-1024x683.jpg\" alt=\"\" class=\"wp-image-95824\" style=\"border-style:none;border-width:0px;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-1024x683.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-300x200.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-768x512.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-1536x1025.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/header-gnlp4243-pfas-hub-ROUGH-TEST-3-2048x1366.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div><\/div>\n<\/div><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>PFAS\uff08\u30d1\u30fc\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff09\u306e\u5206\u6790\u306b\u304a\u3051\u308b\u898f\u5236\u3084\u524d\u51e6\u7406\u6cd5\u306b\u3064\u3044\u3066\u3001\u6700\u65b0\u306e\u60c5\u5831\u3068\u63a8\u5968\u3055\u308c\u308b\u30e9\u30dc\u7528\u54c1\u3092\u7d39\u4ecb\u3057\u307e\u3059\u3002\u6b63\u78ba\u306a\u5206\u6790\u3092\u5b9f\u73fe\u3059\u308b\u305f\u3081\u306e\u30d2\u30f3\u30c8\u3092\u5f97\u3066\u3001\u6c5a\u67d3\u3092\u9632\u304e\u307e\u3057\u3087\u3046\u3002<\/p>\n","protected":false},"author":1,"featured_media":6612,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":"{\"authors\":[2814],\"author_categories\":{\"2814\":\"1\"},\"fallback_author_user\":\"1\",\"ppma_author_box_select\":\"\",\"selected_authors\":[{\"id\":2814,\"display_name\":\"Restek Corporation\",\"is_guest\":1,\"category_id\":\"1\"}]}"},"categories":[789],"tags":[2760],"industries-application":[2288,2289,2272,2271,2266,2269,2275,2274,2287],"post-badge":[],"resource-type":[],"product-library":[2579,2554],"resource-technique":[],"ppma_author":[2814],"class_list":["post-60395","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-soil-sediment-biota-testing-ja","industries-application-air-monitoring-ja","industries-application-environmental-ja","industries-application-clinical-ja","industries-application-clinical-toxicology-ja","industries-application-food-safety-ja","industries-application-food-beverage-ja","industries-application-drinking-water-wastewater-testing-ja","product-library-liquid-reference-standards-ja","product-library-reference-standard-products-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2289,"label":"\u571f\u58cc\uff5c\u5e95\u8cea\uff5c\u751f\u7269\u8a66\u6599 \u5206\u6790"},{"value":2272,"label":"\u5927\u6c17 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2266,"label":"\u81e8\u5e8a"},{"value":2269,"label":"\u81e8\u5e8a\u6bd2\u6027\u5b66"},{"value":2275,"label":"\u98df\u306e\u5b89\u5168"},{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"product-library":[{"value":2579,"label":"\u6a19\u6e96\u6eb6\u6db2"},{"value":2554,"label":"\u6a19\u6e96\u7269\u8cea"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAR3498-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/drcadmin\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":506,"filter":"raw","cat_ID":789,"category_count":506,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","avatar_alt":"","avatar_decorative":"","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/60395","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=60395"}],"version-history":[{"count":20,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/60395\/revisions"}],"predecessor-version":[{"id":104541,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/60395\/revisions\/104541"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6612"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=60395"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=60395"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=60395"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=60395"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=60395"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=60395"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=60395"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=60395"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=60395"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}