{"id":68658,"date":"2026-01-19T14:27:50","date_gmt":"2026-01-19T14:27:50","guid":{"rendered":"https:\/\/discover.restek.com\/?p=68658"},"modified":"2026-02-05T01:19:16","modified_gmt":"2026-02-05T01:19:16","slug":"optimizing-method-standard-hj-834-2017-for-gc-ms-semivolatiles-analysis-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan5233-ja\/optimizing-method-standard-hj-834-2017-for-gc-ms-semivolatiles-analysis-ja","title":{"rendered":"GC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\uff5c\u4e2d\u56fd\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306e\u6700\u9069\u5316"},"content":{"rendered":"\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Key Higlights<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6b21\u4e16\u4ee3\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u6280\u8853\u3092\u7528\u3044\u305fTriMax GC\u30ab\u30e9\u30e0\u306b\u3088\u308b\u3001\u5805\u7262\u3067\u6975\u3081\u3066\u30cb\u30e5\u30fc\u30c8\u30e9\u30eb\u306a\u30b5\u30f3\u30d7\u30eb\u30d5\u30ed\u30fc\u30d1\u30b9\u306e\u5b9f\u73fe<\/li>\n\n\n\n<li>\u6700\u5927\u9650\u306e\u5bfe\u79f0\u6027\u306b\u3088\u308b\u3001\u9178\u3001\u5869\u57fa\u3001\u4e2d\u6027\u3092\u542b\u3080\u5e45\u5e83\u3044\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u4f4e\u6e1b\u304a\u3088\u3073\u3001\u540c\u5b9a\u3068\u5b9a\u91cf\u306e\u5411\u4e0a<\/li>\n\n\n\n<li>\u6700\u9069\u5316\u3055\u308c\u305fGC-MS\u6761\u4ef6\u306b\u3088\u308b\u3001\u30e1\u30bd\u30c3\u30c9\u57fa\u6e96\u3092\u6e80\u305f\u3059\u3053\u3068\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u5411\u4e0a<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-technical-service-JP\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"222\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1.png\" alt=\"\u304a\u554f\u3044\u5408\u308f\u305b\uff5cRestek\" class=\"wp-image-82127\" style=\"width:800px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-300x50.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-1024x170.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-768x127.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u6700\u9069\u5316\u306b\u304a\u3044\u3066RMX-5Sil MS\u30ab\u30e9\u30e0\u304c\u679c\u305f\u3059\u5f79\u5272<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u5e83\u7bc4\u56f2\u306e\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u30af\u30e9\u30b9\u3067\u5e45\u5e83\u3044\u52b9\u679c\u3092\u767a\u63ee\u3059\u308b\u3001\u975e\u5e38\u306b\u4e0d\u6d3b\u6027\u306a\u8868\u9762\u3092\u5f62\u6210\u3059\u308b\u753b\u671f\u7684\u306a\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u672c\u7814\u7a76\u3067\u306f\u3001\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306e\u30c7\u30fc\u30bf\u54c1\u8cea\u57fa\u6e96\u306b\u7167\u3089\u3057\u3066\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u30b7\u30b9\u30c6\u30e0\u9069\u5408\u6027\u3001\u76f4\u7dda\u6027\u3001\u304a\u3088\u3073\u56de\u53ce\u7387\u306b\u95a2\u3059\u308b\u30e1\u30bd\u30c3\u30c9\u57fa\u6e96\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u6642\u9593\u309220\u5206\u77ed\u7e2e\u3059\u308b\u6700\u9069\u5316\u3055\u308c\u305f\u6761\u4ef6\u4e0b\u3067\u3082\u5bb9\u6613\u306b\u6e80\u305f\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">RMX-5Sil MS\u30ab\u30e9\u30e0\u306b\u3088\u308b\u5b9f\u8a3c\u5b9f\u9a13<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306f\u3001\u4eba\u306e\u5065\u5eb7\u3068\u74b0\u5883\u3092\u5b88\u308b\u305f\u3081\u306b\u4e16\u754c\u4e2d\u3067\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5206\u6790\u306b\u306f\u3055\u307e\u3056\u307e\u306a\u691c\u51fa\u5668\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u304c\u3001\u4e2d\u3067\u3082GC-MS\u6cd5\u306f\u6700\u3082\u4e00\u822c\u7684\u3067\u3059\u3002\u4e2d\u83ef\u4eba\u6c11\u5171\u548c\u56fd\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306f\u3001\u571f\u58cc\u304a\u3088\u3073\u5806\u7a4d\u7269\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306eGC-MS\u5206\u6790\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u8a66\u9a13\u5ba4\u304c\u6b63\u78ba\u306a\u7d50\u679c\u3092\u78ba\u5b9f\u306b\u5f97\u3089\u308c\u308b\u3088\u3046\u306b\u3001\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306b\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u306e\u9069\u5408\u6027\u3001\u76f4\u7dda\u6027\u3001\u56de\u53ce\u7387\u306a\u3069\u306e\u4e3b\u8981\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u57fa\u6e96\u304c\u898f\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306f\u3001\u53cd\u5fdc\u6027\u5316\u5408\u7269\u3092\u542b\u3080\u5e45\u5e83\u3044\u5316\u5408\u7269\u306e\u5316\u5b66\u7684\u6027\u8cea\u3067\u69cb\u6210\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u6d41\u8def\u304c\u975e\u5e38\u306b\u4e0d\u6d3b\u6027\u3067\u3042\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u30d5\u30ed\u30fc\u30d1\u30b9\u5185\u306e\u6d3b\u6027\u306f\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u4e0d\u826f\u3084\u4fdd\u6301\u6642\u9593\u306e\u30c9\u30ea\u30d5\u30c8\u306e\u539f\u56e0\u3068\u306a\u308a\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u306e\u8981\u4ef6\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u7814\u7a76\u3067\u306f\u3001\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306b\u6e96\u62e0\u3057\u305f\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u76ee\u6a19\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u3001\u975e\u5e38\u306b\u4e0d\u6d3b\u6027\u306aRMX-5Sil MS\u30ab\u30e9\u30e0\u304c\u3069\u306e\u3088\u3046\u306b\u5f79\u7acb\u3064\u304b\u3092\u5b9f\u8a3c\u3057\u307e\u3059\u3002RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u72ec\u81ea\u306eTriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u6d3b\u6027\u90e8\u4f4d\uff08\u30b7\u30e9\u30ce\u30fc\u30eb\u306a\u3069\uff09\u3092\u9664\u53bb\u3057\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u308f\u305f\u3063\u3066\u52b9\u679c\u3092\u767a\u63ee\u3057\u307e\u3059\u3002RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u5f93\u6765\u306e5sil\u30dd\u30ea\u30de\u30fc\u3092\u542b\u6709\u3057\u3066\u3044\u308b\u305f\u3081\u30015sil\u3092\u76f4\u63a5\u7f6e\u63db\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u9ad8\u4e2d\u6027\u8868\u9762\u306b\u3088\u308a\u3055\u307e\u3056\u307e\u306a\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u6539\u5584\u3055\u308c\u308b\u305f\u3081\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u8981\u4ef6\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u5bb9\u6613\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u7814\u7a76\u3067\u306f\u3001GC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3051\u308b\u30ab\u30e9\u30e0\u306e\u6709\u52b9\u6027\u3092\u5b9f\u8a3c\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u30e9\u30f3\u30bf\u30a4\u30e0\u3092\u77ed\u7e2e\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5411\u4e0a\u3055\u305b\u308b\u6700\u9069\u5316\u3055\u308c\u305f\u88c5\u7f6e\u6761\u4ef6\u3082\u958b\u767a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u5b9f\u8a3c<\/strong>\u5b9f\u9a13\u306e\u8a73\u7d30<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:20px\"><em>\u6a19\u6e96\u8a66\u6599\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u591a\u6210\u5206\u306e\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u6a19\u6e96\u8a66\u6599\u3092\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3\u4e2d\u306b1\u30015\u300110\u300120\u300150ppm\u3067\u8abf\u88fd\u3002\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u3068\u30b5\u30ed\u30b2\u30fc\u30c8\u6a19\u6e96\u7269\u8cea\u306f\u3001\u5404\u6821\u6b63\u6a19\u6e96\u7269\u8cea\u4e2d\u306b40ppm\u3067\u8abf\u88fd\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:20px\"><em>\u5206\u6790\u6761\u4ef6<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">GC-MS\u306b\u3088\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5206\u6790\u306f\u3001\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306e\u6761\u4ef6\u306b\u5f93\u3063\u3066\u5b9f\u65bd\u3002\u307e\u305f\u3001\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3059\u308b\u305f\u3081\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u6761\u4ef6\u3067\u3082\u5b9f\u65bd\u3002<strong>Table I<\/strong> \u306b\u306f\u3001\u4e21\u30a2\u30d7\u30ed\u30fc\u30c1\u306e\u5206\u6790\u6761\u4ef6\u3092\u307e\u3068\u3081\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table I:<\/strong> GC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5206\u6790\u6761\u4ef6<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><th class=\"has-text-align-left\" data-align=\"left\">\u30d1\u30e9\u30e1\u30fc\u30bf <\/th><th>\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u6e96\u62e0\u306e\u6761\u4ef6<\/th><th>\u6700\u9069\u5316\u3055\u308c\u305f\u6761\u4ef6<\/th><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30ab\u30e9\u30e0 <\/td><td>RMX-5Sil MS, 30 m x 0.25 mm ID x 0.25 \u00b5m (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/17323\" target=\"_blank\" rel=\"noopener\">17323<\/a>) <\/td><td>RMX-5Sil MS, 30 m x 0.25 mm ID x 0.25 \u00b5m (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/17323\" target=\"_blank\" rel=\"noopener\">17323<\/a>) <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6ce8\u5165 <\/td><td>1 \u00b5L, \u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9, 280 \u00b0C <\/td><td>1 \u00b5L, \u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9, 280 \u00b0C <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9<\/td><td>\u30d8\u30ea\u30a6\u30e0 at 1 mL\/min (constant flow) <\/td><td>\u30d8\u30ea\u30a6\u30e0 at 1 mL\/min (constant flow) <\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u6607\u6e29<\/td><td>\n\t\t\t\t35 \u00b0C (hold 2 min) to 150 \u00b0C at 15 \u00b0C\/min (hold 5 min) to 290 \u00b0C at 3 \u00b0C\/min (hold 2 min)\n\t\t\t<\/td><td><strong>\u5206\u6790\u3092\u9ad8\u901f\u5316\u3059\u308b\u305f\u3081\u306b\u6607\u6e29\u6761\u4ef6\u3092\u5909\u66f4: <\/strong><br>35 \u00b0C (hold 1 min) to 290 \u00b0C at 8 \u00b0C\/min to 350 \u00b0C at 12 \u00b0C\/min (hold 5 min)<\/td><\/tr><tr><td class=\"has-text-align-left\" data-align=\"left\">\u691c\u51fa\u5668 <\/td><td>\n\t\t\t\tEI; 70 eV; 230 \u00b0C source; 150 \u00b0C quad; scan 35-450 m\/z; solvent delay 5 min; 280 \u00b0Ctransfer line\n\t\t\t<\/td><td>\n\t\t\t\tEI; 70 eV; 230 \u00b0C source; 150 \u00b0C quad; scan 35-450 m\/z; solvent delay 2 min; 280 \u00b0Ctransfer line\n\t\t\t<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u5b9f\u8a3c\u5b9f\u9a13\u306e\u7d50\u679c\u304a\u3088\u3073\u8003\u5bdf<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:20px\"><em>\u30b7\u30b9\u30c6\u30e0\u9069\u5408\u6027<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306b\u5f93\u3063\u3066DFTPP\u3067\u88c5\u7f6e\u3092\u8abf\u6574\u3057\u3001DDT\u304b\u3089DDE\u3068DDD\u3078\u306e\u5206\u89e3\u3092\u8a55\u4fa1\u3059\u308b\u3053\u3068\u3067\u30b7\u30b9\u30c6\u30e0\u9069\u5408\u6027\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002DDE\u3068DDD\u306e\u4e21\u65b9\u3078\u306eDDT\u5206\u89e3\u306f1%\u672a\u6e80\u3067\u300115%\u3092\u8d85\u3048\u306a\u3044\u3068\u3044\u3046\u8981\u4ef6\u306f\u5bb9\u6613\u306b\u6e80\u305f\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:20px\"><em>\u7d50\u679c\u306e\u6bd4\u8f03\u304c\u793a\u3059\u5206\u6790\u6027\u80fd\u306e\u9055\u3044<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 1 <\/strong>\u306b\u793a\u3059\u3088\u3046\u306b\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u6e96\u62e0\u306e\u6761\u4ef6\u3068\u6700\u9069\u5316\u3055\u308c\u305fGC-MS\u6761\u4ef6\u306e\u4e21\u65b9\u3067\u300164\u7a2e\u985e\u306e\u76e3\u8996\u5bfe\u8c61\u3067\u3042\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u30016 \u7a2e\u985e\u306e\u30b5\u30ed\u30b2\u30fc\u30c8\u3001\u304a\u3088\u3073 6 \u7a2e\u985e\u306e\u5185\u90e8\u6a19\u6e96\u7269\u8cea (\u5408\u8a08 76 \u7a2e\u985e\u306e\u5316\u5408\u7269) \u306b\u3064\u3044\u3066\u30015 ppm \u3067\u30b7\u30e3\u30fc\u30d7\u306a\u5bfe\u79f0\u30d4\u30fc\u30af\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u3044\u304f\u3064\u304b\u306e\u5171\u6eb6\u51fa\u304c\u767a\u751f\u3057\u307e\u3057\u305f\u304c\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u306f\u30a4\u30aa\u30f3\u306em\/z\u6bd4\u306b\u3088\u3063\u3066\u5bb9\u6613\u306b\u533a\u5225\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002\u6a19\u6e96\u8a66\u9a13\u6cd5\u306e\u5206\u6790\u6761\u4ef6\u4e0b\u3067\u306f\u3001\u826f\u597d\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3059\u304c\u3001\u5b9f\u884c\u6642\u9593\u304c60\u5206\u3092\u8d85\u3048\u308b\u305f\u3081\u3001\u5206\u6790\u3067\u304d\u308b\u30b5\u30f3\u30d7\u30eb\u6570\u304c\u5236\u9650\u3055\u308c\u307e\u3059\u3002\u6700\u9069\u5316\u3055\u308c\u305f\u5206\u6790\u6761\u4ef6\u3067\u306f\u300140\u5206\u3068\u3044\u3046\u77ed\u6642\u9593\u3067\u5206\u6790\u304c\u53ef\u80fd\u306b\u306a\u308a\u3001\u53b3\u3057\u3044\u7d0d\u671f\u3067\u591a\u304f\u306e\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u304c\u5fc5\u8981\u306a\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u30e9\u30dc\u306b\u3068\u3063\u3066\u6709\u76ca\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 1: <\/strong>\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306e\u5206\u6790\u6761\u4ef6\u4e0b\u3067\u306eTIC\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0 (60\u5206\u4ee5\u4e0a)&nbsp;\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\u80fd\u3067\u3059\uff09<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1533.png\" alt=\"HJ 834-2017 Volatiles and Semivolatiles on RMX-5Sil MS (Method Conditions)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1533<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>17323<\/li><li>23303<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>HJ 834<\/li><li>RMX-library<\/li><li>semivolatiles<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1533.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 2: <\/strong>\u6700\u9069\u5316\u3055\u308c\u305f\u5206\u6790\u6761\u4ef6\u4e0b\u3067\u306eTIC\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0 (40\u5206)&nbsp;\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\u80fd\u3067\u3059\uff09<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1532.png\" alt=\"HJ 834-2017 Volatiles and Semivolatiles on RMX-5Sil MS (Optimized Conditions)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1532<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>17323<\/li><li>23303<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>8270<\/li><li>HJ-834<\/li><li>RMX-library<\/li><li>chinese<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1532.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3445-ja\/ezgc-online-tools-japan\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"312\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4.png\" alt=\"GC\u5206\u6790\u6761\u4ef6, \u30e1\u30bd\u30c3\u30c9\u958b\u767a, \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\uff5cRestek\" class=\"wp-image-81949\" style=\"width:800px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-300x70.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-1024x238.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-768x179.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><em>\u5b9a\u91cf\u5206\u6790\u7d50\u679c\u304b\u3089\u3082\u308f\u304b\u308b\u9ad8\u6027\u80fd<\/em><\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u306b\u3088\u308aS\/N\u6bd4\u304c\u5411\u4e0a\u3059\u308b\u305f\u3081\u3001\u4f4e\u6fc3\u5ea6\u3067\u306e\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u7a4d\u5206\u304c\u53ef\u80fd\u306b\u306a\u308a\u3001\u6642\u9593\u306e\u304b\u304b\u308b\u30e6\u30fc\u30b6\u30fc\u4ecb\u5165\u306e\u5fc5\u8981\u6027\u304c\u6700\u5c0f\u9650\u306b\u6291\u3048\u3089\u308c\u307e\u3059\u3002\u691c\u91cf\u7dda\u7bc4\u56f2\u5168\u4f53\u306b\u308f\u305f\u308b\u6b63\u78ba\u306a\u7a4d\u5206\u306f\u3001\u5206\u6790\u304c\u56f0\u96e3\u306a\u53cd\u5fdc\u6027\u5316\u5408\u7269\u3067\u3042\u3063\u3066\u3082\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u6027\u80fd\u57fa\u6e96\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u30e1\u30bd\u30c3\u30c9\u306e\u6027\u80fd\u306f\u3001\u76f4\u7dda\u6027\uff08\u91cd\u307f\u4ed8\u3051\u306a\u3057\u3001R&gt;0.990\uff09\u3001\u76f8\u5bfe\u5fdc\u7b54\u4fc2\u6570\uff08RSD &lt;30%\uff09\u304a\u3088\u3073\u4e2d\u70b9\u6a19\u6e96\u7269\u8cea\u306e\u56de\u53ce\u7387\uff0810 ppm\u306770\uff5e130%\u306e\u56de\u53ce\u7387\uff09\u306b\u3088\u3063\u3066\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u691c\u51fa\u9650\u754c\uff08LOD\uff09\u3068\u5b9a\u91cf\u9650\u754c\uff08LOQ\uff09\u306f\u305d\u308c\u305e\u308c\u3001LOD = 3.3 x \u6700\u4f4e\u691c\u91cf\u7dda\u70b9\/\u691c\u91cf\u7dda\u52fe\u914d\u306e\u6a19\u6e96\u504f\u5dee\u3001LOQ = 10 x \u6700\u4f4e\u691c\u91cf\u7dda\u70b9\/\u691c\u91cf\u7dda\u52fe\u914d\u306e\u6a19\u6e96\u504f\u5dee\u3068\u3044\u3046\u4e00\u822c\u7684\u306b\u8a8d\u3081\u3089\u308c\u305f\u65b9\u6cd5\u3067\u8a08\u7b97\u3057\u3001\u8a08\u7b97\u3055\u308c\u305f\u5024\u306f\u30e1\u30bd\u30c3\u30c9\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308bLOD\u304a\u3088\u3073LOQ\u5024\u3068\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u30e1\u30bd\u30c3\u30c9\u306e\u8981\u4ef6\u3067\u306f\u3001LOD\u3068LOQ\u306f\u30b5\u30f3\u30d7\u30eb\u6fc3\u5ea6\u3068\u3057\u3066\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u8a66\u9a13\u3067\u306f\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u4f7f\u7528\u3057\u306a\u304b\u3063\u305f\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u6fc3\u5ea6\u306f\u7406\u8ad6\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u8cea\u91cf20 g\u3001\u6700\u7d42\u62bd\u51fa\u6db2\u91cf1 mL\u306b\u57fa\u3065\u3044\u3066\u62bd\u51fa\u6db2\u6fc3\u5ea6\u306b\u63db\u7b97\u3057\u307e\u3057\u305f\uff08<strong>Table II<\/strong>\u53c2\u7167\uff09\u3002\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u4f7f\u7528\u3057\u306a\u3044\u5834\u5408\u3001\u30ab\u30e9\u30e0\u6027\u80fd\u306e\u5dee\u306f\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd\u306e\u6709\u52b9\u6027\u304b\u3089\u5207\u308a\u96e2\u3059\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5b9a\u91cf\u5206\u6790\u3067\u306f\u3001\u6700\u9069\u5316\u3055\u308c\u305f\u5206\u6790\u6761\u4ef6\u3092\u4f7f\u7528\u3057\u3066\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u3092\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u7d50\u679c\u306e\u8981\u7d04\u3092<strong>Table II<\/strong>\u306b\u3001\u500b\u3005\u306e\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5024\u3092<strong>Table III<\/strong>\u306b\u793a\u3057\u307e\u3059\u3002\u3059\u3079\u3066\u306e\u5316\u5408\u7269 (\u5185\u90e8\u6a19\u6e96\u3068\u30b5\u30ed\u30b2\u30fc\u30c8\u3092\u9664\u304f) \u306f\u3001RRF RSD &lt;30% \u304a\u3088\u3073 R&gt;0.990 \u306e\u76f4\u7dda\u6027\u57fa\u6e96\u306b\u5408\u683c\u3057\u307e\u3057\u305f\u3002RSD\u5024\u306f2.1\uff5e22.5%\u3001R\u306f0.999\uff5e1.00\u306e\u7bc4\u56f2\u3067\u3057\u305f\u3002HJ 834\u3067\u306f\u5fc5\u9808\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u304c\u3001R<sup>2<\/sup>\u3082\u307e\u305f\u8a55\u4fa1\u3055\u308c\u307e\u3057\u305f \u3002\u3053\u306e\u7814\u7a76\u3067\u306f\u3001R<sup>2<\/sup>\u306f\u5404\u5316\u5408\u7269\u30670.995\u3092\u8d85\u3048\u30010.997-1.0\u306e\u7bc4\u56f2\u3067\u3057\u305f \u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table II:<\/strong> \u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017 GC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790 (\u6700\u9069\u5316\u3055\u308c\u305f\u6761\u4ef6)\u306e\u7d50\u679c\u307e\u3068\u3081<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><\/td><th class=\"has-text-align-center\" data-align=\"center\">RRF %RSD (&lt;30%) <\/th><th class=\"has-text-align-center\" data-align=\"center\">R<sup>2<\/sup>* (&gt;0.990) <\/th><th class=\"has-text-align-center\" data-align=\"center\">R (&gt;0.990) <\/th><th class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\tLOD (Method HJ 834-2017)\n\t\t\t<\/th><th class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\tLOQ (Method HJ 834-2017)\n\t\t\t<\/th><th class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t%Recovery\n\t\t\t<\/th><\/tr><tr><td>\u8a31\u5bb9\u7bc4\u56f2\u5185<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t64\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t64\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t64\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t64\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t64\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t64\n\t\t\t<\/td><\/tr><tr><td>\u8a31\u5bb9\u7bc4\u56f2\u5916<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0\n\t\t\t<\/td><\/tr><tr><td>\u6700\u9ad8\u5024<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t23%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.89\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.98\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t109%\n\t\t\t<\/td><\/tr><tr><td>\u6700\u4f4e\u5024 <\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.997\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.02\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.05\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t75%\n\t\t\t<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">*R<sup>2<\/sup> \u306f\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u3067\u306f\u898f\u5b9a\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u3002GC-MS\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u306e\u4ed6\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b\u76f4\u7dda\u6027\u306e\u6307\u6a19\u3067\u3042\u308b\u305f\u3081\u3001\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002<\/figcaption><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Table III:<\/strong> \u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017 GC-MS\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790 (\u6700\u9069\u5316\u3055\u308c\u305f\u6761\u4ef6)\u306e\u5316\u5408\u7269\u5225\u7d50\u679c<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><th>\u5316\u5408\u7269 <\/th><th class=\"has-text-align-center\" data-align=\"center\">RRF %RSD (&lt;30%) <\/th><th class=\"has-text-align-center\" data-align=\"center\">R<sup>2<\/sup>* <\/th><th class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\tR\n\t\t\t<\/th><th class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\tMethod HJ 834-2017 LOD (ppm)\n\t\t\t<\/th><th class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\tMethod HJ 834-2017 LOQ (ppm)\n\t\t\t<\/th><th class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\tLOD (ppm)\n\t\t\t<\/th><th class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\tLOQ (ppm)\n\t\t\t<\/th><th class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t%Recovery of 10 ppm\n\t\t\t<\/th><\/tr><tr><td>\n\t\t\t\tBis(N-methoxy-N-methylamino)methane\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.36\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.22\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t105%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.33\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.11\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t95%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBis(2-chloroethyl) ether\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t3%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.17\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.58\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t99%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2-chloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.16\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.55\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t96%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, 1,3-dichloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.68\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t100%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, 1,4-dichloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.19\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.62\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t97%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, 1,2-dichloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.13\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.45\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t96%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2-methyl-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.25\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.82\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t101%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBis(2-chloro-1-methylethyl) ether\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.34\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.13\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t104%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\t1-Propanamine, N-nitroso-N-propyl-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t3%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.43\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.43\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t109%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tp-Cresol\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.11\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.38\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t100%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tEthane, hexachloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t10%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.53\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.77\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t97%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, nitro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.23\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.76\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t102%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tIsophorone\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.09\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.30\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t99%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2-nitro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t10%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.15\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.50\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t96%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2,3-dimethyl-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.25\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.84\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t99%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tMethane, bis(2-chloroethoxy)-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.09\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.31\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t100%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2,4-dichloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t13%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t16.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.09\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.30\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t98%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, 1,2,4-trichloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t11%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.16\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.54\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t98%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tNaphthalene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t9%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.16\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.54\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t99%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tp-Chloroaniline\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.17\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.57\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t94%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\t1,3-Butadiene, 1,1,2,3,4,4-hexachloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.29\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.98\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t97%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2-chloro-5-methyl-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.23\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.77\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t93%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tNaphthalene, 1-methyl-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t10%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.07\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.22\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t98%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tHexachlorocyclopentadiene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t22%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.27\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.92\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t89%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2,4,6-trichloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t21%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.13\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.44\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t92%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2,4,5-trichloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t21%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.27\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.91\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t92%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tNaphthalene, 1-chloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t15%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.10\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.32\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t95%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tDimethyl (2-nitroanilino)maleate\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t21%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.62\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.05\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t89%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tDimethyl phthalate\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t15%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.12\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.39\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t93%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, 2-methyl-1,3-dinitro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t20%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.56\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.87\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t90%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBiphenylene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t18%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.10\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.32\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t99%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tm-Nitroaniline\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t22%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.89\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.98\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t90%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tAcenaphthene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t10%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.02\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.08\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t99%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2,4-dinitro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t16%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.997\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.69\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.32\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t75%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 4-nitro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t13%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.23\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.75\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t85%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tDibenzofuran\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t14%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.09\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.29\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t99%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, 1-methyl-2,4-dinitro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t23%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.13\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.42\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t91%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tDiethyl Phthalate\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t13%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.05\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.18\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t96%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tFluorene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t15%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.04\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.14\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t98%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, 1-chloro-4-phenoxy-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.80\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.12\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.39\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t103%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, 1-chloro-3-phenoxy-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t13%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t16.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.33\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.11\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t95%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, 2-methyl, 4,6-dinitro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t22%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.60\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6.40\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.39\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.30\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t103%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tAzobenzene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t6.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t24.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.15\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.50\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t104%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, 1-bromo-4-phenoxy-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t13%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.67\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t95%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzene, hexachloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.02\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.07\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t99%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhenol, pentachloro-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t11%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.39\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.30\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t89%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\t9H-Fluorene, 9-methylene-\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.03\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.11\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t101%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tAnthracene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t13%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t16.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.03\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.09\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t104%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tCarbazole\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t11%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.07\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.24\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t96%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tDibutyl phthalate\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t12%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.03\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.10\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t99%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tFluoranthene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t10%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t16.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.07\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.22\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t100%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPyrene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t9%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.03\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.11\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t101%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzyl butyl phthalate\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t12%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.998\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.20\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.68\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t94%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenz[a]anthracene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.08\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.26\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t95%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tTriphenylene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.13\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.42\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t106%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBis(2-ethylhexyl) phthalate\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t15%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t16.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.09\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.29\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t102%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tPhthalic acid, hept-4-yl octyl ester\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t18%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.02\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.05\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t103%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzo[b]fluoranthene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t17%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.09\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.31\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t96%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzo[k]fluoranthene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t16%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t16.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.09\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.32\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t102%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzo[a]pyrene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t15%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.08\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.26\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t104%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tIndeno[1,2,3-cd]pyrene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t11%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.05\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.18\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t96%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tDiben[a,h]anthracene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t5%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.999\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t2.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t8.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.10\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.35\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t107%\n\t\t\t<\/td><\/tr><tr><td>\n\t\t\t\tBenzo[ghi]perylene\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t7%\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t1.000\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t4.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t16.00\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.04\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t0.15\n\t\t\t<\/td><td class=\"has-text-align-center\" data-align=\"center\">\n\t\t\t\t106%\n\t\t\t<\/td><\/tr><\/tbody><\/table><figcaption class=\"wp-element-caption\">*R<sup>2<\/sup> \u306f\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u3067\u306f\u898f\u5b9a\u3055\u308c\u3066\u3044\u307e\u305b\u3093\u3002GC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306e\u4ed6\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b\u76f4\u7dda\u6027\u306e\u6307\u6a19\u3067\u3042\u308b\u305f\u3081\u3001\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002<\/figcaption><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\u691c\u8a3c\u6e08\u307fRMX-5Sil\u30ab\u30e9\u30e0\u306e\u5b9f\u529b<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u7814\u7a76\u3067\u306f\u3001\u9ad8\u4e0d\u6d3b\u6027\u306aRMX-5Sil MS\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u5e45\u5e83\u3044\u7a2e\u985e\u306e\u3001\u5206\u6790\u304c\u56f0\u96e3\u306a\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u30e1\u30bd\u30c3\u30c9\u306b\u6e96\u62e0\u3057\u305f\u7d50\u679c\u304c\u5f97\u3089\u308c\u308b\u3053\u3068\u3092\u5b9f\u8a3c\u3057\u307e\u3057\u305f\u3002\u30ab\u30e9\u30e0\u8868\u9762\u304c\u4e0d\u6d3b\u6027\u3067\u3042\u308b\u305f\u3081\u3001\u30b7\u30e3\u30fc\u30d7\u3067\u5bfe\u79f0\u7684\u306a\u30d4\u30fc\u30af\u304c\u5f97\u3089\u308c\u3001\u7a4d\u5206\u304c\u7c21\u7d20\u5316\u3055\u308c\u3001\u30b7\u30b9\u30c6\u30e0\u9069\u5408\u6027\u3001\u76f4\u7dda\u6027\uff08RRF %RSD \u304a\u3088\u3073R<sup>2<\/sup> \uff09\u3001LOD\u3001LOQ\u3001\u304a\u3088\u3073\u56de\u53ce\u7387\u306b\u304a\u3044\u3066\u512a\u308c\u305f\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306e\u8981\u4ef6\u3092\u6e80\u305f\u3057\u3001\u76f4\u7dda\u6027\u306e\u9ad8\u3044\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3059\u308b\u3053\u3068\u306b\u52a0\u3048\u3001\u4eca\u56de\u958b\u767a\u3055\u308c\u305f\u6700\u9069\u5316\u3055\u308c\u305fGC-MS\u6761\u4ef6\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u6642\u9593\u309260\u5206\u304b\u308940\u5206\u306b\u77ed\u7e2e\u3057\u3001\u30cf\u30a4\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306a\u30e9\u30dc\u3067\u306e\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u5411\u4e0a\u3092\u53ef\u80fd\u306b\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><a href=\"https:\/\/discover.restek.com\/ja\/rmx\/\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"2534\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-scaled.png\" alt=\"\u5316\u5408\u7269\u306e\u5438\u7740\u3092\u6291\u3048\u305fGC\u30ab\u30e9\u30e0\" class=\"wp-image-81098\" style=\"width:800px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-scaled.png 2560w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-300x297.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-1024x1014.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-768x760.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-1536x1521.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-2048x2027.png 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/a><figcaption class=\"wp-element-caption\">\u6b8b\u5b58\u6d3b\u6027\u70b9\u7531\u6765\u306e\u4e0d\u8981\u306a\u30ab\u30e9\u30e0\u8868\u9762\u76f8\u4e92\u4f5c\u7528\u3092\u6291\u3048\u3066\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u30ab\u30e9\u30e0\u5bff\u547d\u3092\u6539\u5584<\/figcaption><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">                                \u30ab\u30bf\u30ed\u30b0No. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">                                \u30ab\u30bf\u30ed\u30b0No. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31271\">                                \u30ab\u30bf\u30ed\u30b0No. 31271                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Benzo[a]pyrene Standard, 1000 \u00b5g\/mL, Acetone, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31271\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31276\">                                \u30ab\u30bf\u30ed\u30b0No. 31276                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Dibenz[a,h]anthracene Standard, 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31276\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31279\">                                \u30ab\u30bf\u30ed\u30b0No. 31279                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Indeno[1,2,3-cd]Pyrene Standard, 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31279\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31273\">                                \u30ab\u30bf\u30ed\u30b0No. 31273                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Benzo[g,h,i]perylene Standard, 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31273\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<style>\n\/* JS\u304c\u4ed8\u3051\u308b\u30af\u30e9\u30b9\u3067\u975e\u8868\u793a\u306b\u3059\u308b *\/\n.rmx-hide-related {\n  display: none !important;\n}\n<\/style>\n\n<script>\n(function () {\n  function hideRelatedSections(root) {\n    if (!root) return;\n\n    \/\/ \u898b\u51fa\u3057\u5019\u88dc\uff08h2\/h3\u7b49\uff09\u3092\u5e83\u3081\u306b\u63a2\u7d22\n    const headings = root.querySelectorAll('h1,h2,h3,h4,h5,h6');\n\n    headings.forEach(h => {\n      const title = (h.textContent || '').trim().toLowerCase();\n\n      \/\/ \"Related SKUs\" \/ \"Related Searches\" \u3092\u5224\u5b9a\n      const isRelatedSkus = title === 'related skus' || title === 'related sku';\n      const isRelatedSearches = title === 'related searches' || title === 'related search';\n\n      if (isRelatedSkus || isRelatedSearches) {\n        \/\/ \u898b\u51fa\u3057\u81ea\u8eab\u3092\u96a0\u3059\n        h.classList.add('rmx-hide-related');\n\n        \/\/ \u76f4\u5f8c\u306e\u30ea\u30b9\u30c8\uff08ul\/ol\u7b49\uff09\u3084\u3001\u95a2\u9023\u30b3\u30f3\u30c6\u30ca\u3092\u96a0\u3059\n        \/\/ \u307e\u305a nextElementSibling \u3092\u96a0\u3059\uff08\u591a\u304f\u306e\u30c6\u30f3\u30d7\u30ec\u304c\u3053\u308c\u3067OK\uff09\n        let next = h.nextElementSibling;\n        if (next) next.classList.add('rmx-hide-related');\n\n        \/\/ \u5ff5\u306e\u305f\u3081\u3001\u6b21\u304c\u30b3\u30f3\u30c6\u30ca\u3067\u305d\u306e\u4e2d\u306b\u30ea\u30b9\u30c8\u304c\u3042\u308b\u5834\u5408\u3082\u96a0\u3059\n        \/\/ \uff08next \u304c div \u306e\u3053\u3068\u3082\u3042\u308b\u305f\u3081\uff09\n        if (next && next.querySelectorAll) {\n          const lists = next.querySelectorAll('ul,ol');\n          lists.forEach(li => li.classList.add('rmx-hide-related'));\n        }\n      }\n    });\n  }\n\n  function run() {\n    \/\/ Chromatogram Block\u306e\u5916\u307e\u3067\u5dfb\u304d\u8fbc\u307e\u306a\u3044\u3088\u3046\u3001\u53ef\u80fd\u306a\u3089\u30d6\u30ed\u30c3\u30af\u7bc4\u56f2\u3092\u7d5e\u308b\n    \/\/ 1) \u307e\u305a \"Chromatogram Block\" \u306e\u8fd1\u508d\u3092\u63a2\u3059\uff08\u30af\u30e9\u30b9\u304c\u3042\u308c\u3070\u305d\u3053\u306b\u7f6e\u63db\u63a8\u5968\uff09\n    const candidate =\n      document.querySelector('.chromatogram-block') ||\n      document.querySelector('[data-block-name*=\"chromatogram\" i]') ||\n      document;\n\n    hideRelatedSections(candidate);\n  }\n\n  \/\/ \u521d\u56de\n  if (document.readyState === 'loading') {\n    document.addEventListener('DOMContentLoaded', run);\n  } else {\n    run();\n  }\n\n  \/\/ \u30d7\u30ec\u30d3\u30e5\u30fc\u304c\u5f8c\u304b\u3089\u63cf\u753b\u3055\u308c\u308b\u30b1\u30fc\u30b9\u306b\u5099\u3048\u3066\u3001\u5c11\u3057\u3060\u3051\u518d\u5b9f\u884c\n  setTimeout(run, 500);\n  setTimeout(run, 1500);\n})();\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>Key Higlights \u6700\u9069\u5316\u306b\u304a\u3044\u3066RMX-5Sil MS\u30ab\u30e9\u30e0\u304c\u679c\u305f\u3059\u5f79\u5272 RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u5e83\u7bc4\u56f2\u306e\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u30af\u30e9\u30b9\u3067\u5e45\u5e83\u3044\u52b9\u679c\u3092\u767a\u63ee\u3059\u308b\u3001\u975e\u5e38\u306b\u4e0d\u6d3b\u6027\u306a\u8868\u9762\u3092\u5f62\u6210\u3059\u308b\u753b\u671f\u7684\u306a\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u672c\u7814\u7a76\u3067\u306f\u3001\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306e\u30c7\u30fc\u30bf\u54c1\u8cea\u57fa\u6e96\u306b\u7167\u3089\u3057\u3066\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002\u30b7\u30b9\u30c6\u30e0\u9069\u5408\u6027\u3001\u76f4\u7dda\u6027\u3001\u304a\u3088\u3073\u56de\u53ce\u7387\u306b\u95a2\u3059\u308b\u30e1\u30bd\u30c3\u30c9\u57fa\u6e96\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u6642\u9593\u309220\u5206\u77ed\u7e2e\u3059\u308b\u6700\u9069\u5316\u3055\u308c\u305f\u6761\u4ef6\u4e0b\u3067\u3082\u5bb9\u6613\u306b\u6e80\u305f\u3055\u308c\u307e\u3057\u305f\u3002 RMX-5Sil MS\u30ab\u30e9\u30e0\u306b\u3088\u308b\u5b9f\u8a3c\u5b9f\u9a13 \u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306f\u3001\u4eba\u306e\u5065\u5eb7\u3068\u74b0\u5883\u3092\u5b88\u308b\u305f\u3081\u306b\u4e16\u754c\u4e2d\u3067\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u5206\u6790\u306b\u306f\u3055\u307e\u3056\u307e\u306a\u691c\u51fa\u5668\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u304c\u3001\u4e2d\u3067\u3082GC-MS\u6cd5\u306f\u6700\u3082\u4e00\u822c\u7684\u3067\u3059\u3002\u4e2d\u83ef\u4eba\u6c11\u5171\u548c\u56fd\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306f\u3001\u571f\u58cc\u304a\u3088\u3073\u5806\u7a4d\u7269\u30b5\u30f3\u30d7\u30eb\u4e2d\u306e\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306eGC-MS\u5206\u6790\u306b\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u8a66\u9a13\u5ba4\u304c\u6b63\u78ba\u306a\u7d50\u679c\u3092\u78ba\u5b9f\u306b\u5f97\u3089\u308c\u308b\u3088\u3046\u306b\u3001\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306b\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u306e\u9069\u5408\u6027\u3001\u76f4\u7dda\u6027\u3001\u56de\u53ce\u7387\u306a\u3069\u306e\u4e3b\u8981\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u57fa\u6e96\u304c\u898f\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306f\u3001\u53cd\u5fdc\u6027\u5316\u5408\u7269\u3092\u542b\u3080\u5e45\u5e83\u3044\u5316\u5408\u7269\u306e\u5316\u5b66\u7684\u6027\u8cea\u3067\u69cb\u6210\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30b5\u30f3\u30d7\u30eb\u6d41\u8def\u304c\u975e\u5e38\u306b\u4e0d\u6d3b\u6027\u3067\u3042\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u30d5\u30ed\u30fc\u30d1\u30b9\u5185\u306e\u6d3b\u6027\u306f\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u4e0d\u826f\u3084\u4fdd\u6301\u6642\u9593\u306e\u30c9\u30ea\u30d5\u30c8\u306e\u539f\u56e0\u3068\u306a\u308a\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u306e\u8981\u4ef6\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002 \u3053\u306e\u7814\u7a76\u3067\u306f\u3001\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306b\u6e96\u62e0\u3057\u305f\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u76ee\u6a19\u3092\u9054\u6210\u3059\u308b\u305f\u3081\u306b\u3001\u975e\u5e38\u306b\u4e0d\u6d3b\u6027\u306aRMX-5Sil MS\u30ab\u30e9\u30e0\u304c\u3069\u306e\u3088\u3046\u306b\u5f79\u7acb\u3064\u304b\u3092\u5b9f\u8a3c\u3057\u307e\u3059\u3002RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u72ec\u81ea\u306eTriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u6d3b\u6027\u90e8\u4f4d\uff08\u30b7\u30e9\u30ce\u30fc\u30eb\u306a\u3069\uff09\u3092\u9664\u53bb\u3057\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u308f\u305f\u3063\u3066\u52b9\u679c\u3092\u767a\u63ee\u3057\u307e\u3059\u3002RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u5f93\u6765\u306e5sil\u30dd\u30ea\u30de\u30fc\u3092\u542b\u6709\u3057\u3066\u3044\u308b\u305f\u3081\u30015sil\u3092\u76f4\u63a5\u7f6e\u63db\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u304c\u3001\u9ad8\u4e2d\u6027\u8868\u9762\u306b\u3088\u308a\u3055\u307e\u3056\u307e\u306a\u5316\u5408\u7269\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u6539\u5584\u3055\u308c\u308b\u305f\u3081\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u8981\u4ef6\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u5bb9\u6613\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u7814\u7a76\u3067\u306f\u3001GC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3051\u308b\u30ab\u30e9\u30e0\u306e\u6709\u52b9\u6027\u3092\u5b9f\u8a3c\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u30e9\u30f3\u30bf\u30a4\u30e0\u3092\u77ed\u7e2e\u3057\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3092\u5411\u4e0a\u3055\u305b\u308b\u6700\u9069\u5316\u3055\u308c\u305f\u88c5\u7f6e\u6761\u4ef6\u3082\u958b\u767a\u3057\u307e\u3057\u305f\u3002 \u5b9f\u8a3c\u5b9f\u9a13\u306e\u8a73\u7d30 \u6a19\u6e96\u8a66\u6599\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd \u591a\u6210\u5206\u306e\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u6a19\u6e96\u8a66\u6599\u3092\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3\u4e2d\u306b1\u30015\u300110\u300120\u300150ppm\u3067\u8abf\u88fd\u3002\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u3068\u30b5\u30ed\u30b2\u30fc\u30c8\u6a19\u6e96\u7269\u8cea\u306f\u3001\u5404\u6821\u6b63\u6a19\u6e96\u7269\u8cea\u4e2d\u306b40ppm\u3067\u8abf\u88fd\u3002 \u5206\u6790\u6761\u4ef6 GC-MS\u306b\u3088\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5206\u6790\u306f\u3001\u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u306e\u6761\u4ef6\u306b\u5f93\u3063\u3066\u5b9f\u65bd\u3002\u307e\u305f\u3001\u5206\u6790\u6642\u9593\u3092\u77ed\u7e2e\u3059\u308b\u305f\u3081\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u6761\u4ef6\u3067\u3082\u5b9f\u65bd\u3002Table I \u306b\u306f\u3001\u4e21\u30a2\u30d7\u30ed\u30fc\u30c1\u306e\u5206\u6790\u6761\u4ef6\u3092\u307e\u3068\u3081\u3066\u3044\u307e\u3059\u3002 Table I: GC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5206\u6790\u6761\u4ef6 \u30d1\u30e9\u30e1\u30fc\u30bf \u6a19\u6e96\u8a66\u9a13\u6cd5HJ 834-2017\u6e96\u62e0\u306e\u6761\u4ef6 \u6700\u9069\u5316\u3055\u308c\u305f\u6761\u4ef6 \u30ab\u30e9\u30e0 RMX-5Sil MS, 30 m x 0.25 mm ID x 0.25 \u00b5m (cat.# 17323) RMX-5Sil MS, 30 m x 0.25 mm ID x&#8230;<\/p>\n","protected":false},"author":34,"featured_media":61032,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[785],"tags":[2745],"industries-application":[2289,2271],"post-badge":[2752],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340,2345],"ppma_author":[454,448,441,2657,452],"class_list":["post-68658","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja","tag-rmx-resources","industries-application-soil-sediment-biota-testing-ja","industries-application-environmental-ja","post-badge-new","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}],"post_tag":[{"value":2745,"label":"RMX \u8d44\u6e90\u5e93"}],"industries-application":[{"value":2289,"label":"\u571f\u58cc\uff5c\u5e95\u8cea\uff5c\u751f\u7269\u8a66\u6599 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"post-badge":[{"value":2752,"label":"New"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAN5233-1024x568.jpg",1024,568,true],"author_info":{"display_name":"Erica Pack, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/erica-pack-phd\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":785,"category_count":88,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":[{"term_id":2745,"name":"RMX \u8d44\u6e90\u5e93","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2745,"taxonomy":"post_tag","description":"\u7acb\u5373\u63a2\u7d22 RMX \u8d44\u6e90\u5e93","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":448,"user_id":28,"is_guest":0,"slug":"grace-idowu","display_name":"Grace Idowu, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-idowu-grace.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-idowu-grace.jpg"},"author_category":"1","first_name":"Grace","last_name":"Idowu, PhD","user_url":"","job_title":"","description":"Dr. Grace Idowu was formerly with Restek as a principal scientist in the GC applications laboratory. She received her PhD in chemistry from the University of Manitoba, Canada; her master\u2019s degree in environmental and petroleum geochemistry from Newcastle University, UK; and her bachelor of technology degree in pure and applied chemistry from Ladoke Akintola University, Nigeria. Grace's doctoral and post-doctoral research focused on the development and validation of GC methods for polycyclic aromatic compounds in environmental matrices. She has extensive experience developing analytical methods for GC-MS, GC-MS\/MS, and GCxGC-MS, and her current research focuses primarily on persistent organic pollutants in environmental matrices."},{"term_id":441,"user_id":21,"is_guest":0,"slug":"chris-english","display_name":"Chris English","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png"},"author_category":"1","first_name":"Chris","last_name":"English","user_url":"https:\/\/www.linkedin.com\/in\/chris-english-28214912\/","job_title":"Sr. R&D Manager","description":"Since 2004, Chris has managed a team of chemists in Restek's innovations laboratory who perform new product testing, method development, and applications work. Before taking the reins of our lab, he spent seven years as an environmental chemist and was critical to the development of Restek\u2019s current line of volatile GC columns. Prior to joining Restek, he operated a variety of gas chromatographic detectors conducting method development and sample analysis. Chris holds a BS in environmental science from Saint Michael's College."},{"term_id":2657,"user_id":70,"is_guest":0,"slug":"ramkumar-dhandapani-phd","display_name":"Ramkumar Dhandapani, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg"},"author_category":"1","first_name":"Ramkumar","last_name":"Dhandapani","user_url":"https:\/\/www.linkedin.com\/in\/dr-ramkumar-dhandapani-b9012424\/?skipRedirect=true&enhance=null","job_title":"Director of Product Management","description":"Dr. Ramkumar Dhandapani\u00a0is a seasoned analytical chemist with over\u00a023 years of experience\u00a0in the chromatography industry and a Ph.D. in analytical chemistry. During his career, he has specialized in method development, validation, and the troubleshooting of chromatography methods. He has developed numerous regulatory-compliant methods across diverse sectors, including\u00a0environmental analysis, food quality and safety, pharmaceutical, fuels, and chemical industries. Currently, Dr. Dhandapani is the Director of Product Management at Restek, he is keen on innovation in chromatography and scaling breakthrough innovations\u00a0to market as commercial products."},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/68658","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=68658"}],"version-history":[{"count":62,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/68658\/revisions"}],"predecessor-version":[{"id":86831,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/68658\/revisions\/86831"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/61032"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=68658"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=68658"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=68658"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=68658"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=68658"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=68658"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=68658"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=68658"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=68658"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}