{"id":69288,"date":"2026-01-19T19:42:04","date_gmt":"2026-01-19T19:42:04","guid":{"rendered":"https:\/\/discover.restek.com\/?p=69288"},"modified":"2026-02-20T07:02:26","modified_gmt":"2026-02-20T07:02:26","slug":"increase-lab-efficiency-with-a-consolidated-trace-level-semivolatiles-method-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evfa5253-ja\/increase-lab-efficiency-with-a-consolidated-trace-level-semivolatiles-method-ja","title":{"rendered":"\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u62e1\u5f35\u3068\u52b9\u7387\u5316"},"content":{"rendered":"\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Key Highlights<\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:1.2rem\">\u753b\u671f\u7684\u306aTriMax\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u306b\u3088\u308a\u3001\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u5316\u5408\u7269\u3092\u542b\u3080150\u6210\u5206\u306b\u5bfe\u3057\u3066\u3001\u4f4e\u5438\u7740\u306a\u30d7\u30ec\u30df\u30a2\u30e0GC\u30ab\u30e9\u30e0\u304c\u5b9f\u73fe<\/li>\n\n\n\n<li style=\"font-size:1.2rem\">\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u306b\u3088\u3063\u3066\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5927\u5e45\u306b\u6539\u5584\u3055\u308c\u3001\u5e83\u7bc4\u56f2\u306a\u534a\u63ee\u767a\u6027\u5316\u5408\u7269\u30921\u672c\u306e\u30ab\u30e9\u30e0\u3067\u5206\u6790\u53ef\u80fd\u306b\u3001\u307e\u305f\u30d4\u30b3\u30b0\u30e9\u30e0\u30ec\u30d9\u30eb\u306e\u9ad8\u611f\u5ea6\u5206\u6790\u3092\u5b9f\u73fe<\/li>\n\n\n\n<li style=\"font-size:1.2rem\">150\u6210\u5206SVOC\u5411\u3051\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u30e1\u30bd\u30c3\u30c9\u3092\u305d\u306e\u307e\u307e\u4f7f\u7528\u3059\u308b\u3053\u3068\u3082\u3001\u7121\u511f\u306e<em>EZ<\/em>GC Chromatogram Modeler\u3092\u7528\u3044\u3066\u3001\u81ea\u8eab\u306e\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306b\u5408\u308f\u305b\u305f\u6761\u4ef6\u3092\u77ed\u6642\u9593\u3067\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u3082\u53ef\u80fd<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u74b0\u5883\u5206\u6790\u306b\u304a\u3051\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u306e\u6e2c\u5b9a\u3067\u306f\u3001\u5316\u5b66\u7279\u6027\u3084\u53cd\u5fdc\u6027\u306e\u591a\u69d8\u6027\u304c\u5927\u304d\u306a\u8ab2\u984c\u3068\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u306a\u3069\u7269\u6027\u306e\u7570\u306a\u308b\u5316\u5408\u7269\u304c\u6df7\u5728\u3059\u308b\u5834\u5408\u3001\u7279\u306b\u5fae\u91cf\u5206\u6790\u306b\u304a\u3044\u3066\u306f\u5b89\u5b9a\u3057\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u5f97\u308b\u305f\u3081\u306b\u3001\u5316\u5408\u7269\u7279\u6027\u306b\u5fdc\u3058\u3066GC\u30ab\u30e9\u30e0\u3092\u4f7f\u3044\u5206\u3051\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u80cc\u666f\u304b\u3089\u3001\u4e00\u672c\u306e\u30ab\u30e9\u30e0\u3067\u3088\u308a\u591a\u304f\u306e\u5316\u5408\u7269\u3092\u6e2c\u5b9a\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308c\u3070\u3001\u30e9\u30dc\u306e\u751f\u7523\u6027\u3092\u9ad8\u3081\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<br>\u305f\u3060\u3057\u3001\u3088\u308a\u5e45\u5e83\u3044\u5316\u5408\u7269\u3092\u5bfe\u8c61\u3068\u3059\u308b\u591a\u6210\u5206\u4e00\u6589\u5206\u6790\u3092\u5b9f\u73fe\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30ab\u30e9\u30e0\u8868\u9762\u306e\u4e0d\u6d3b\u6027\u5316\u304c\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u5f93\u6765\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306f\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u3088\u3063\u3066\u6027\u80fd\u5dee\u304c\u751f\u3058\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001Restek\u306e\u6b21\u4e16\u4ee3\u578bTriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306f\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u9ad8\u3044\u52b9\u679c\u304c\u5f97\u3089\u308c\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u304a\u308a\u3001\u4ed6\u793e\u306e\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u3088\u308a\u3082\u512a\u308c\u305f\u6027\u80fd\u3092\u793a\u3059\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059[1]\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5225\u306e\u7814\u7a76\u306b\u304a\u3044\u3066\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u304c\u3088\u308a\u591a\u304f\u306eSVOC\u30af\u30e9\u30b9\u3067\u5bfe\u79f0\u6027\u306e\u9ad8\u3044\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u793a\u3057\u3001\u305d\u306e\u7d50\u679c\u3068\u3057\u3066\u3088\u308a\u591a\u304f\u306e\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u76f4\u7dda\u6027\u3084\u56de\u53ce\u7387\u306e\u30c7\u30fc\u30bf\u57fa\u6e96\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059[2]\u3002 \u672c\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306f\u3001\u3053\u306e\u7814\u7a76\u3092\u3055\u3089\u306b\u767a\u5c55\u3055\u305b\u3001\u5206\u6790\u6761\u4ef6\u3092\u6700\u9069\u5316\u3057\u3001\u5185\u90e8\u6a19\u6e96\u53ca\u3073\u30b5\u30ed\u30b2\u30fc\u30c8\u3092\u542b\u3080150\u6210\u5206\u306eSVOC\u306b\u3064\u3044\u3066\u691c\u8a0e\u3092\u884c\u3044\u307e\u3057\u305f\u3002<strong>Figure 1<\/strong>\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u306b\u5bfe\u5fdc\u3057\u305fSRM\u6761\u4ef6\u3092\u8a2d\u5b9a\u3057\u3001<strong>Figure 2<\/strong>\u3067\u306f0.1\uff5e10 pg\u306e\u5fae\u91cf\u5206\u6790\u306b\u304a\u3044\u3066\u3082\u512a\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<br>\u7279\u306b\u3001\u30da\u30f3\u30bf\u30af\u30ed\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u30842,4-\u30b8\u30cb\u30c8\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u306a\u3069\u306e\u9178\u6027\u5316\u5408\u7269\u3001\u30d4\u30ea\u30b8\u30f3\u3084\u30d9\u30f3\u30b8\u30b8\u30f3\u306a\u3069\u306e\u5869\u57fa\u6027\u5316\u5408\u7269\u306f\u3001\u5f93\u6765\u30ab\u30e9\u30e0\u3067\u306f\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u4e71\u308c\u3084\u3059\u3044\u6210\u5206\u3067\u3042\u308b\u306b\u3082\u95a2\u308f\u3089\u305a\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u3067\u306f\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5206\u6790\u304c\u96e3\u3057\u3044\u5316\u5408\u7269\u306b\u304a\u3051\u308b\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u6539\u5584\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u9069\u5408\u6027\u8a66\u9a13\u306e\u89b3\u70b9\u3067\u3082\u6975\u3081\u3066\u6709\u7528\u3067\u3042\u308a\u3001\u4fdd\u6301\u5206\u96e2\u304c\u96e3\u3057\u3044\u4e2d\u6027PAH\uff08\u4f8b\uff1a\u30d9\u30f3\u30be[b]\uff0f[k]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\uff09\u3082\u9069\u5207\u306b\u5206\u96e2\u3055\u308c\u305f\u3053\u3068\u304b\u3089\u3001TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u304cSVOC\u306e\u3088\u3046\u306a\u5e45\u5e83\u3044\u5316\u5408\u7269\u3092\u5bfe\u8c61\u3068\u3059\u308b\u5206\u6790\u306b\u6975\u3081\u3066\u6709\u52b9\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u30e1\u30bd\u30c3\u30c9\u306f 150 \u6210\u5206 (\u5bfe\u8c61\u6210\u5206\u306fcat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/31907\" target=\"_blank\" rel=\"noopener\">31907<\/a>) \u306b\u5bfe\u5fdc\u3057\u305f\u7d71\u5408\u30e1\u30bd\u30c3\u30c9\u3068\u3057\u3066\u6a5f\u80fd\u3057\u307e\u3059\u304c\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3084\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306b\u5408\u308f\u305b\u3066\u6700\u9069\u5316\u3057\u305f\u3044\u5834\u5408\u306b\u306f\u3001Restek \u304c\u63d0\u4f9b\u3059\u308b\u7121\u511f\u306e<em>EZ<\/em>GC Chromatogram Modeler\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u8fc5\u901f\u306b\u30e1\u30bd\u30c3\u30c9\u3092\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1: \u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u9ad8\u611f\u5ea6\u5206\u6790\u306b\u5bfe\u5fdc\u3057\u305f\u62e1\u5f35\u30e1\u30bd\u30c3\u30c9\u2015\u30b5\u30ed\u30b2\u30fc\u30c8\u53ca\u3073\u5185\u90e8\u6a19\u6e96\u3092\u542b\u3080150\u6210\u5206\u3092\u3001100 ppb\uff08\u30aa\u30f3\u30ab\u30e9\u30e010 pg\uff09\u3067\u4e00\u6589\u5206\u6790\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1527.png\" alt=\"Semivolatiles on RMX-5Sil MS by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1527<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31907<\/li><li>31886<\/li><li>31024<\/li><li>31025<\/li><li>17323<\/li><li>23267<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>8270<\/li><li>8270e<\/li><li>RMX-library<\/li><li>environmental<\/li><li>semivolatile<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1527.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:\u00a0\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u8a87\u308bRMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u4f4e\u6fc3\u5ea6\u304b\u3064\u5206\u6790\u304c\u56f0\u96e3\u3068\u3055\u308c\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u3082\u3001\u5e45\u5e83\u3044\u30c7\u30fc\u30bf\u8981\u4ef6\u3092\u6e80\u305f\u3059\u5805\u7262\u306a\u5206\u6790\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1526.png\" alt=\"Select Semivolatiles at Low Levels on RMX-5Sil MS by GC-MS\/MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_EV1526<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>31907<\/li><li>31886<\/li><li>31024<\/li><li>31025<\/li><li>17323<\/li><li>23267<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>RMX-library<\/li><li>semivolatiles<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ev1526.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n<\/div><\/div><\/div>\n\n<style>.kb-image69288_9ffba7-e4.kb-image-is-ratio-size, .kb-image69288_9ffba7-e4 .kb-image-is-ratio-size{max-width:700px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image69288_9ffba7-e4.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image69288_9ffba7-e4 .kb-image-is-ratio-size{align-self:unset;}.kb-image69288_9ffba7-e4 figure{max-width:700px;}.kb-image69288_9ffba7-e4 .image-is-svg, .kb-image69288_9ffba7-e4 .image-is-svg img{width:100%;}.kb-image69288_9ffba7-e4 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image69288_9ffba7-e4\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3445-ja\/ezgc-online-tools-japan\" class=\"kb-advanced-image-link\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"238\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-1024x238.png\" alt=\"GC\u5206\u6790\u6761\u4ef6, \u30e1\u30bd\u30c3\u30c9\u958b\u767a, \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\uff5cRestek\" class=\"kb-img wp-image-81949\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-1024x238.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-300x70.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-768x179.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>\u53c2\u7167\u6587\u732e<\/strong><\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnbr4923-ja\/rmx-gc-columns-unleash-your-performance-ja\">RMX GC\u30ab\u30e9\u30e0\u30ab\u30bf\u30ed\u30b0<\/a>, GNBR4923-JA, Restek Corporation, 2026.&nbsp;<\/li>\n\n\n\n<li>E. Pack, J. Hoisington, C. English, R. Dhandapani, and C. Myers, <a href=\"https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan4920-ja\/comprehensive-trace-level-gc-ms-ms-semivolatiles-method-ja\">\u5fae\u91cf\u30ec\u30d9\u30eb\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306eGC-MS\/MS\u4e00\u6589\u5206\u6790\u6cd5\uff1a\u30c7\u30fc\u30bf\u54c1\u8cea\u306e\u7dad\u6301\u3068\u691c\u51fa\u4e0b\u9650\u306e\u6539\u5584<\/a>, Application note, EVAN4920-JP, Restek Corporation, 2025<\/li>\n<\/ol>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image69288_76807b-d0.kb-image-is-ratio-size, .kb-image69288_76807b-d0 .kb-image-is-ratio-size{max-width:845px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image69288_76807b-d0.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image69288_76807b-d0 .kb-image-is-ratio-size{align-self:unset;}.kb-image69288_76807b-d0 figure{max-width:845px;}.kb-image69288_76807b-d0 .image-is-svg, .kb-image69288_76807b-d0 .image-is-svg img{width:100%;}.kb-image69288_76807b-d0:not(.kb-image-is-ratio-size) .kb-img, .kb-image69288_76807b-d0.kb-image-is-ratio-size{padding-right:50px;padding-left:50px;}.kb-image69288_76807b-d0 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image69288_76807b-d0\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/discover.restek.com\/ja\/rmx\/\" class=\"kb-advanced-image-link\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1014\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-1024x1014.png\" alt=\"\u4e0d\u6d3b\u6027\u5ea6\u306e\u9ad8\u3044GC\u30ab\u30e9\u30e0\" class=\"kb-img wp-image-81470\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-1024x1014.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-300x297.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-768x760.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-1536x1521.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-2048x2027.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>\u30ab\u30e9\u30e0\u5185\u306e\u6d3b\u6027\u70b9\u3092\u6291\u3048\u305f\u3001\u9ad8\u611f\u5ea6\u30fb\u9577\u5bff\u547d\u306a\u30ab\u30e9\u30e0<\/figcaption><\/figure><\/div>\n\n\n\n<div class=\"wp-block-columns are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:7rem;padding-bottom:var(--wp--preset--spacing--20);padding-left:7rem\"><\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u95a2\u9023\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">                                \u30ab\u30bf\u30ed\u30b0No. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">                                \u30ab\u30bf\u30ed\u30b0No. 23305                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">                                \u30ab\u30bf\u30ed\u30b0No. 31907                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">SVOC MegaMix 150 Kit, 1 mL\/ampul; 6 ampuls\/kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">                                \u30ab\u30bf\u30ed\u30b0No. 31025                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Acid Surrogate Mix (4\/89 SOW), 2000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">                                \u30ab\u30bf\u30ed\u30b0No. 31024                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Base Neutral Surrogate Mix (4\/89 SOW), 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">                                \u30ab\u30bf\u30ed\u30b0No. 31886                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Revised SV Internal Standard Mix, 4000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\" style=\"margin-right:15rem;margin-left:15rem\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-technical-service-JP\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"222\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1.png\" alt=\"\u304a\u554f\u3044\u5408\u308f\u305b\uff5cRestek\" class=\"wp-image-82127\" style=\"width:700px\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-300x50.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-1024x170.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-768x127.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure>\n<\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<style>\n\/* JS\u304c\u4ed8\u3051\u308b\u30af\u30e9\u30b9\u3067\u975e\u8868\u793a\u306b\u3059\u308b *\/\n.rmx-hide-related {\n  display: none !important;\n}\n<\/style>\n\n<script>\n(function () {\n  function hideRelatedSections(root) {\n    if (!root) return;\n\n    \/\/ \u898b\u51fa\u3057\u5019\u88dc\uff08h2\/h3\u7b49\uff09\u3092\u5e83\u3081\u306b\u63a2\u7d22\n    const headings = root.querySelectorAll('h1,h2,h3,h4,h5,h6');\n\n    headings.forEach(h => {\n      const title = (h.textContent || '').trim().toLowerCase();\n\n      \/\/ \"Related SKUs\" \/ \"Related Searches\" \u3092\u5224\u5b9a\n      const isRelatedSkus = title === 'related skus' || title === 'related sku';\n      const isRelatedSearches = title === 'related searches' || title === 'related search';\n\n      if (isRelatedSkus || isRelatedSearches) {\n        \/\/ \u898b\u51fa\u3057\u81ea\u8eab\u3092\u96a0\u3059\n        h.classList.add('rmx-hide-related');\n\n        \/\/ \u76f4\u5f8c\u306e\u30ea\u30b9\u30c8\uff08ul\/ol\u7b49\uff09\u3084\u3001\u95a2\u9023\u30b3\u30f3\u30c6\u30ca\u3092\u96a0\u3059\n        \/\/ \u307e\u305a nextElementSibling \u3092\u96a0\u3059\uff08\u591a\u304f\u306e\u30c6\u30f3\u30d7\u30ec\u304c\u3053\u308c\u3067OK\uff09\n        let next = h.nextElementSibling;\n        if (next) next.classList.add('rmx-hide-related');\n\n        \/\/ \u5ff5\u306e\u305f\u3081\u3001\u6b21\u304c\u30b3\u30f3\u30c6\u30ca\u3067\u305d\u306e\u4e2d\u306b\u30ea\u30b9\u30c8\u304c\u3042\u308b\u5834\u5408\u3082\u96a0\u3059\n        \/\/ \uff08next \u304c div \u306e\u3053\u3068\u3082\u3042\u308b\u305f\u3081\uff09\n        if (next && next.querySelectorAll) {\n          const lists = next.querySelectorAll('ul,ol');\n          lists.forEach(li => li.classList.add('rmx-hide-related'));\n        }\n      }\n    });\n  }\n\n  function run() {\n    \/\/ Chromatogram Block\u306e\u5916\u307e\u3067\u5dfb\u304d\u8fbc\u307e\u306a\u3044\u3088\u3046\u3001\u53ef\u80fd\u306a\u3089\u30d6\u30ed\u30c3\u30af\u7bc4\u56f2\u3092\u7d5e\u308b\n    \/\/ 1) \u307e\u305a \"Chromatogram Block\" \u306e\u8fd1\u508d\u3092\u63a2\u3059\uff08\u30af\u30e9\u30b9\u304c\u3042\u308c\u3070\u305d\u3053\u306b\u7f6e\u63db\u63a8\u5968\uff09\n    const candidate =\n      document.querySelector('.chromatogram-block') ||\n      document.querySelector('[data-block-name*=\"chromatogram\" i]') ||\n      document;\n\n    hideRelatedSections(candidate);\n  }\n\n  \/\/ \u521d\u56de\n  if (document.readyState === 'loading') {\n    document.addEventListener('DOMContentLoaded', run);\n  } else {\n    run();\n  }\n\n  \/\/ \u30d7\u30ec\u30d3\u30e5\u30fc\u304c\u5f8c\u304b\u3089\u63cf\u753b\u3055\u308c\u308b\u30b1\u30fc\u30b9\u306b\u5099\u3048\u3066\u3001\u5c11\u3057\u3060\u3051\u518d\u5b9f\u884c\n  setTimeout(run, 500);\n  setTimeout(run, 1500);\n})();\n<\/script>\n\n","protected":false},"excerpt":{"rendered":"<p>Key Highlights \u74b0\u5883\u5206\u6790\u306b\u304a\u3051\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u306e\u6e2c\u5b9a\u3067\u306f\u3001\u5316\u5b66\u7279\u6027\u3084\u53cd\u5fdc\u6027\u306e\u591a\u69d8\u6027\u304c\u5927\u304d\u306a\u8ab2\u984c\u3068\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u306a\u3069\u7269\u6027\u306e\u7570\u306a\u308b\u5316\u5408\u7269\u304c\u6df7\u5728\u3059\u308b\u5834\u5408\u3001\u7279\u306b\u5fae\u91cf\u5206\u6790\u306b\u304a\u3044\u3066\u306f\u5b89\u5b9a\u3057\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u5f97\u308b\u305f\u3081\u306b\u3001\u5316\u5408\u7269\u7279\u6027\u306b\u5fdc\u3058\u3066GC\u30ab\u30e9\u30e0\u3092\u4f7f\u3044\u5206\u3051\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u3088\u3046\u306a\u80cc\u666f\u304b\u3089\u3001\u4e00\u672c\u306e\u30ab\u30e9\u30e0\u3067\u3088\u308a\u591a\u304f\u306e\u5316\u5408\u7269\u3092\u6e2c\u5b9a\u3067\u304d\u308b\u3088\u3046\u306b\u306a\u308c\u3070\u3001\u30e9\u30dc\u306e\u751f\u7523\u6027\u3092\u9ad8\u3081\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u3088\u308a\u5e45\u5e83\u3044\u5316\u5408\u7269\u3092\u5bfe\u8c61\u3068\u3059\u308b\u591a\u6210\u5206\u4e00\u6589\u5206\u6790\u3092\u5b9f\u73fe\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30ab\u30e9\u30e0\u8868\u9762\u306e\u4e0d\u6d3b\u6027\u5316\u304c\u91cd\u8981\u306b\u306a\u308a\u307e\u3059\u304c\u3001\u5f93\u6765\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306f\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u3088\u3063\u3066\u6027\u80fd\u5dee\u304c\u751f\u3058\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3057\u305f\u3002\u4e00\u65b9\u3001Restek\u306e\u6b21\u4e16\u4ee3\u578bTriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306f\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u9ad8\u3044\u52b9\u679c\u304c\u5f97\u3089\u308c\u308b\u3088\u3046\u306b\u8a2d\u8a08\u3055\u308c\u3066\u304a\u308a\u3001\u4ed6\u793e\u306e\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u3088\u308a\u3082\u512a\u308c\u305f\u6027\u80fd\u3092\u793a\u3059\u3053\u3068\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059[1]\u3002 \u5225\u306e\u7814\u7a76\u306b\u304a\u3044\u3066\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u304c\u3088\u308a\u591a\u304f\u306eSVOC\u30af\u30e9\u30b9\u3067\u5bfe\u79f0\u6027\u306e\u9ad8\u3044\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u793a\u3057\u3001\u305d\u306e\u7d50\u679c\u3068\u3057\u3066\u3088\u308a\u591a\u304f\u306e\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u76f4\u7dda\u6027\u3084\u56de\u53ce\u7387\u306e\u30c7\u30fc\u30bf\u57fa\u6e96\u3092\u6e80\u305f\u3059\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059[2]\u3002 \u672c\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3\u3067\u306f\u3001\u3053\u306e\u7814\u7a76\u3092\u3055\u3089\u306b\u767a\u5c55\u3055\u305b\u3001\u5206\u6790\u6761\u4ef6\u3092\u6700\u9069\u5316\u3057\u3001\u5185\u90e8\u6a19\u6e96\u53ca\u3073\u30b5\u30ed\u30b2\u30fc\u30c8\u3092\u542b\u3080150\u6210\u5206\u306eSVOC\u306b\u3064\u3044\u3066\u691c\u8a0e\u3092\u884c\u3044\u307e\u3057\u305f\u3002Figure 1\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u306b\u5bfe\u5fdc\u3057\u305fSRM\u6761\u4ef6\u3092\u8a2d\u5b9a\u3057\u3001Figure 2\u3067\u306f0.1\uff5e10 pg\u306e\u5fae\u91cf\u5206\u6790\u306b\u304a\u3044\u3066\u3082\u512a\u308c\u305f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u7279\u306b\u3001\u30da\u30f3\u30bf\u30af\u30ed\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u30842,4-\u30b8\u30cb\u30c8\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u306a\u3069\u306e\u9178\u6027\u5316\u5408\u7269\u3001\u30d4\u30ea\u30b8\u30f3\u3084\u30d9\u30f3\u30b8\u30b8\u30f3\u306a\u3069\u306e\u5869\u57fa\u6027\u5316\u5408\u7269\u306f\u3001\u5f93\u6765\u30ab\u30e9\u30e0\u3067\u306f\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u4e71\u308c\u3084\u3059\u3044\u6210\u5206\u3067\u3042\u308b\u306b\u3082\u95a2\u308f\u3089\u305a\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u3067\u306f\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u306e\u5206\u6790\u304c\u96e3\u3057\u3044\u5316\u5408\u7269\u306b\u304a\u3051\u308b\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u6539\u5584\u306f\u3001\u30b7\u30b9\u30c6\u30e0\u9069\u5408\u6027\u8a66\u9a13\u306e\u89b3\u70b9\u3067\u3082\u6975\u3081\u3066\u6709\u7528\u3067\u3042\u308a\u3001\u4fdd\u6301\u5206\u96e2\u304c\u96e3\u3057\u3044\u4e2d\u6027PAH\uff08\u4f8b\uff1a\u30d9\u30f3\u30be[b]\uff0f[k]\u30d5\u30eb\u30aa\u30e9\u30f3\u30c6\u30f3\uff09\u3082\u9069\u5207\u306b\u5206\u96e2\u3055\u308c\u305f\u3053\u3068\u304b\u3089\u3001TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u304cSVOC\u306e\u3088\u3046\u306a\u5e45\u5e83\u3044\u5316\u5408\u7269\u3092\u5bfe\u8c61\u3068\u3059\u308b\u5206\u6790\u306b\u6975\u3081\u3066\u6709\u52b9\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002 \u672c\u30e1\u30bd\u30c3\u30c9\u306f 150 \u6210\u5206 (\u5bfe\u8c61\u6210\u5206\u306fcat.# 31907) \u306b\u5bfe\u5fdc\u3057\u305f\u7d71\u5408\u30e1\u30bd\u30c3\u30c9\u3068\u3057\u3066\u6a5f\u80fd\u3057\u307e\u3059\u304c\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3084\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306b\u5408\u308f\u305b\u3066\u6700\u9069\u5316\u3057\u305f\u3044\u5834\u5408\u306b\u306f\u3001Restek \u304c\u63d0\u4f9b\u3059\u308b\u7121\u511f\u306eEZGC Chromatogram Modeler\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u8fc5\u901f\u306b\u30e1\u30bd\u30c3\u30c9\u3092\u30ab\u30b9\u30bf\u30de\u30a4\u30ba\u3067\u304d\u307e\u3059\u3002 \u53c2\u7167\u6587\u732e<\/p>\n","protected":false},"author":34,"featured_media":81870,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"show","_kad_post_layout":"left","_kad_post_sidebar_id":"","_kad_post_content_style":"boxed","_kad_post_vertical_padding":"show","_kad_post_feature":"show","_kad_post_feature_position":"behind","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[2745],"industries-application":[2751,2289,2271,2287],"post-badge":[2752],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2365,2340,2345],"ppma_author":[454,441,2657,452],"class_list":["post-69288","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-rmx-resources","industries-application-semivolatiles","industries-application-soil-sediment-biota-testing-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja","post-badge-new","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-ms-ms-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2745,"label":"RMX \u8d44\u6e90\u5e93"}],"industries-application":[{"value":2751,"label":"Semivolatiles"},{"value":2289,"label":"\u571f\u58cc\uff5c\u5e95\u8cea\uff5c\u751f\u7269\u8a66\u6599 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"post-badge":[{"value":2752,"label":"New"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA5253-1-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Erica Pack, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/erica-pack-phd\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2745,"name":"RMX \u8d44\u6e90\u5e93","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2745,"taxonomy":"post_tag","description":"\u7acb\u5373\u63a2\u7d22 RMX \u8d44\u6e90\u5e93","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":441,"user_id":21,"is_guest":0,"slug":"chris-english","display_name":"Chris English","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png"},"author_category":"1","first_name":"Chris","last_name":"English","user_url":"https:\/\/www.linkedin.com\/in\/chris-english-28214912\/","job_title":"Sr. R&D Manager","description":"Since 2004, Chris has managed a team of chemists in Restek's innovations laboratory who perform new product testing, method development, and applications work. Before taking the reins of our lab, he spent seven years as an environmental chemist and was critical to the development of Restek\u2019s current line of volatile GC columns. Prior to joining Restek, he operated a variety of gas chromatographic detectors conducting method development and sample analysis. Chris holds a BS in environmental science from Saint Michael's College."},{"term_id":2657,"user_id":70,"is_guest":0,"slug":"ramkumar-dhandapani-phd","display_name":"Ramkumar Dhandapani, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg"},"author_category":"1","first_name":"Ramkumar","last_name":"Dhandapani","user_url":"https:\/\/www.linkedin.com\/in\/dr-ramkumar-dhandapani-b9012424\/?skipRedirect=true&enhance=null","job_title":"Director of Product Management","description":"Dr. Ramkumar Dhandapani\u00a0is a seasoned analytical chemist with over\u00a023 years of experience\u00a0in the chromatography industry and a Ph.D. in analytical chemistry. During his career, he has specialized in method development, validation, and the troubleshooting of chromatography methods. He has developed numerous regulatory-compliant methods across diverse sectors, including\u00a0environmental analysis, food quality and safety, pharmaceutical, fuels, and chemical industries. Currently, Dr. Dhandapani is the Director of Product Management at Restek, he is keen on innovation in chromatography and scaling breakthrough innovations\u00a0to market as commercial products."},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/69288","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=69288"}],"version-history":[{"count":125,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/69288\/revisions"}],"predecessor-version":[{"id":88049,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/69288\/revisions\/88049"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/81870"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=69288"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=69288"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=69288"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=69288"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=69288"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=69288"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=69288"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=69288"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=69288"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}