{"id":69290,"date":"2026-01-19T15:45:00","date_gmt":"2026-01-19T15:45:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=69290"},"modified":"2026-02-05T01:15:19","modified_gmt":"2026-02-05T01:15:19","slug":"pushing-the-boundaries-of-low-level-gc-ms-semivolatiles-analysis-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evfa4921-ja\/pushing-the-boundaries-of-low-level-gc-ms-semivolatiles-analysis-ja","title":{"rendered":"GC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\uff1a\u5fae\u91cf\u5206\u6790\u306e\u9650\u754c\u306b\u6311\u3080"},"content":{"rendered":"\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:1.5rem\">\u4f4e\u6fc3\u5ea6SVOC\u5206\u6790\u306b\u304a\u3051\u308bGC-MS\u306e\u611f\u5ea6\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u8ab2\u984c<\/h2>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:1.8rem\">Key Highlights<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:1.2rem\">\u6b21\u4e16\u4ee3 TriMax \u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u3001\u3088\u308a\u4f4e\u3044\u691c\u51fa\u9650\u754c\u3067\u3082\u54c1\u8cea\u57fa\u6e96\u3092\u6e80\u305f\u3059\u30c7\u30fc\u30bf\u304c\u53d6\u5f97\u53ef\u80fd\u306b<\/li>\n\n\n\n<li style=\"font-size:1.2rem\">\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u306b\u3088\u308a\u3001\u5206\u6790\u304c\u96e3\u3057\u3044\u6210\u5206\u3092\u542b\u3080\u591a\u69d8\u306aSVOC\u306b\u304a\u3044\u3066\u30b7\u30e3\u30fc\u30d7\u3067\u5bfe\u79f0\u6027\u306e\u9ad8\u3044\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u5b9f\u73fe<\/li>\n\n\n\n<li style=\"font-size:1.2rem\">\u9ad8\u611f\u5ea6\u5206\u6790\uff08SIM\uff09\u3068\u6c4e\u7528\u7684\u306a\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\uff08scan\uff09\u306e\u4e21\u65b9\u306b\u9069\u3057\u305fGC-MS\u5206\u6790\u6761\u4ef6\u3092\u78ba\u7acb<\/li>\n<\/ul>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">SVOC\u306eGC-MS\u5206\u6790\u3067\u691c\u51fa\u9650\u754c\u306e\u6539\u5584\u304c\u6c42\u3081\u3089\u308c\u308b\u80cc\u666f<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5206\u6790\u3092\u5b9f\u65bd\u3059\u308b\u30e9\u30dc\u3067\u306f\u3001\u9867\u5ba2\u8981\u6c42\u3084\u6eb6\u5a92\u524a\u6e1b\uff08\u898f\u5236\u5bfe\u5fdc\u30fb\u30b3\u30b9\u30c8\u524a\u6e1b\uff09\u306e\u305f\u3081\u3001\u691c\u51fa\u9650\u754c\u306e\u5f15\u304d\u4e0b\u3052\u304c\u5e38\u306b\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002 MS \u30d9\u30fc\u30b9\u306e\u30e1\u30bd\u30c3\u30c9\uff08\u4f8b\uff1aEPA 8270\uff09\u306f\u4e00\u822c\u7684\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u3042\u308a\u3001MS \u3092\u6d3b\u7528\u3059\u308b\u3053\u3068\u3067\u3088\u308a\u4f4e\u3044\u691c\u51fa\u9650\u754c\u3092\u5b9f\u73fe\u3067\u304d\u307e\u3059\u3002<br><br>EPA Method 8270\u306b\u4ee3\u8868\u3055\u308c\u308bMS\u3092\u7528\u3044\u305fSVOC\u306e\u5206\u6790\u624b\u6cd5\u306f\u5e83\u304f\u6d3b\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u30e9\u30dc\u306f\u76ee\u7684\u306b\u5fdc\u3058\u3066\u30d9\u30b9\u30c8\u306a\u691c\u51fa\u9650\u754c\u3092\u9054\u6210\u3067\u304d\u308b\u88c5\u7f6e\u3092\u67d4\u8edf\u306b\u9078\u629e\u3067\u304d\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001GC-MS\/MS\u306e\u3088\u3046\u306a\u9ad8\u611f\u5ea6\u306a\u88c5\u7f6e\u3092\u63a1\u7528\u3059\u308b\u5834\u5408\u3082\u3042\u308b\u4e00\u65b9\u3067\u3001GC-MS\u3092\u7528\u3044\u3066SIM\u306b\u3088\u308b\u611f\u5ea6\u5411\u4e0a\u3092\u56f3\u308b\u904b\u7528\u3084\u3001\u3088\u308a\u6c4e\u7528\u7684\u306ascan\u30e2\u30fc\u30c9\u306b\u3088\u308b\u5206\u6790\u3092\u9078\u629e\u3059\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002<br><\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">SVOC\u5206\u6790\u306b\u304a\u3051\u308bGC-MS\u306eScan\u6cd5\u3068SIM\u6cd5\u306e\u4f7f\u3044\u5206\u3051<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">SIM\u3068scan\u306f\u3069\u3061\u3089\u3082GC-MS\u3067\u5b9f\u65bd\u53ef\u80fd\u3067\u3059\u304c\u3001scan\u304c\u5e45\u5e83\u3044\u8cea\u91cf\u7bc4\u56f2\u306e\u4fe1\u53f7\u3092\u307e\u3068\u3081\u3066\u53d6\u5f97\u3059\u308b\u30b7\u30f3\u30d7\u30eb\u3067\u6c4e\u7528\u7684\u306a\u624b\u6cd5\u3067\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001SIM\u306f\u7279\u5b9a\u30a4\u30aa\u30f3\u3092\u7279\u5b9a\u306e\u4fdd\u6301\u6642\u9593\u306b\u7d5e\u3063\u3066\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u3088\u308a\u9ad8\u3044\u611f\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002SIM\u306f\u30e1\u30bd\u30c3\u30c9\u306e\u8a2d\u5b9a\u3084\u7dad\u6301\u304c\u7169\u96d1\u306b\u306a\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u691c\u51fa\u9650\u754c\u306e\u5f15\u304d\u4e0b\u3052\u3092\u691c\u8a0e\u3059\u308b\u5834\u5408\u3001\u65b0\u305f\u306a\u88c5\u7f6e\u6295\u8cc7\u3092\u884c\u308f\u305a\u306b\u611f\u5ea6\u3092\u9ad8\u3081\u308b\u9078\u629e\u80a2\u3068\u3057\u3066\u3001GC-MS\u306eSIM\u904b\u7528\u304c\u6709\u529b\u5019\u88dc\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">\u4f4e\u6fc3\u5ea6SVOC\u5206\u6790\u3092\u60f3\u5b9a\u3057\u305fGC-MS\u6e2c\u5b9a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc<\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u306f\u3001\u30b7\u30f3\u30d7\u30eb\u3067\u5805\u7262\u306ascan\u3068\u3001GC-MS\/MS\u306b\u4ee3\u308f\u308a\u5f97\u308b\u9ad8\u611f\u5ea6\u306aSIM\u3068\u3044\u3046\u4e8c\u3064\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u76ee\u7684\u306b\u5fdc\u3058\u3066\u9078\u629e\u3067\u304d\u308b\u3088\u3046\u3001scan\u3068SIM\u306e\u4e21\u30e2\u30fc\u30c9\u306b\u304a\u3051\u308bGC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306e\u6761\u4ef6\u3092\u78ba\u7acb\u3057\u307e\u3057\u305f\uff08Figure 1 \uff06 Figure 2\uff09\u3002<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">RMX-5Sil MS \u30ab\u30e9\u30e0\u306b\u3088\u308bSVOC\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u8a55\u4fa1<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">\u3044\u305a\u308c\u306e\u30e1\u30bd\u30c3\u30c9\u3082RMX-5Sil MS\u30ab\u30e9\u30e0\u3092\u63a1\u7528\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30ab\u30e9\u30e0\u306f\u6a19\u6e96\u7684\u306a5sil\u306e\u9078\u629e\u6027\u3092\u5099\u3048\u306a\u304c\u3089\u3082\u3001\u6b21\u4e16\u4ee3\u306eTriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u3001\u6975\u3081\u3066\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u5b9f\u73fe\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059[1,2]\u3002Figure 2\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u30d9\u30f3\u30b8\u30b8\u30f3\u3001\u30da\u30f3\u30bf\u30af\u30ed\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u30012,4-\u30b8\u30cb\u30c8\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u3068\u3044\u3063\u305f\u4e3b\u8981\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u3001\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u306f\u4e00\u8cab\u3057\u3066\u54c1\u8cea\u76ee\u6a19\uff08\u22642\uff09\u3092\u6e80\u305f\u3057\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u5206\u96e2\u304c\u96e3\u3057\u3044PAH \u985e\u306b\u3064\u3044\u3066\u306f\u3001EPA 8270\u306e\u30b7\u30b9\u30c6\u30e0\u9069\u5408\u6027\u3067\u6c42\u3081\u3089\u308c\u308bvalley% \u57fa\u6e96\uff08&gt;50%\uff09\u306b\u5bfe\u3057\u3001benzo[b]fluoranthene\u3068 benzo[k]fluoranthene\u306e\u30d4\u30fc\u30af\u9593 valley% \u306f94%\u3001indeno[1,2,3-cd]pyrene \u3068 dibenz[a,h]anthracene\u306evalley%\u306f 95%\u3068\u3001\u6975\u3081\u3066\u826f\u597d\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-medium-font-size\">pg\u30ec\u30d9\u30eb\u306b\u304a\u3051\u308bSVOC\u306e\u611f\u5ea6\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u8a55\u4fa1\u7d50\u679c<\/h3>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">\u307e\u305f\u3001\u672c\u7a3f\u3067\u793a\u3057\u305f\u6761\u4ef6\u4e0b\u3067 RMX-5Sil MS \u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u3068\u3053\u308d\u3001scan \u30e2\u30fc\u30c9\u3067\u306f 1 ng on-column\u3001SIM \u30e2\u30fc\u30c9\u3067\u306f 200 pg on-column\u3068\u3044\u3046\u6975\u3081\u3066\u4f4e\u3044\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf\u306b\u304a\u3044\u3066\u3082\u3001\u5e45\u5e83\u3044\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u5341\u5206\u306a\u5206\u96e2\u6027\u80fd\u304c\u7dad\u6301\u3055\u308c\u3001MS\u306e\u691c\u51fa\u9650\u754c\u8fd1\u508d\u306b\u304a\u3044\u3066\u3082\u611f\u5ea6\u304a\u3088\u3073\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u306e\u4e21\u7acb\u304c\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image69290_4d91f0-fd.kb-image-is-ratio-size, .kb-image69290_4d91f0-fd .kb-image-is-ratio-size{max-width:800px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image69290_4d91f0-fd.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image69290_4d91f0-fd .kb-image-is-ratio-size{align-self:unset;}.kb-image69290_4d91f0-fd figure{max-width:800px;}.kb-image69290_4d91f0-fd .image-is-svg, .kb-image69290_4d91f0-fd .image-is-svg img{width:100%;}.kb-image69290_4d91f0-fd:not(.kb-image-is-ratio-size) .kb-img, .kb-image69290_4d91f0-fd.kb-image-is-ratio-size{padding-right:100px;padding-left:100px;}.kb-image69290_4d91f0-fd .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image69290_4d91f0-fd\"><figure class=\"aligncenter\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-technical-service-JP\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"222\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1.png\" alt=\"\u304a\u554f\u3044\u5408\u308f\u305b\uff5cRestek\" class=\"kb-img wp-image-82127\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-300x50.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-1024x170.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-768x127.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">GC-MS\u306b\u3088\u308b\u4f4e\u6fc3\u5ea6SVOC165\u6210\u5206\u5206\u6790\u306e\u5b9f\u6e2c\u30c7\u30fc\u30bf<\/h2>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\">GC-MS\u306b\u3088\u308b\u4f4e\u6fc3\u5ea6SVOC 165\u6210\u5206\u5206\u6790\u306b\u304a\u3051\u308bRMX-5Sil MS\u30ab\u30e9\u30e0\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u8a55\u4fa1\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-0bd16b36 wp-block-columns-is-layout-flex\" style=\"padding-right:100px;padding-left:100px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-theme-palette-7-background-color has-background has-medium-font-size wp-block-paragraph\" style=\"border-radius:10px;margin-top:0px;margin-bottom:0px;padding-right:2px;padding-left:2px\"><strong>Figure 1. scan Mode (1 ng on-column)<\/strong><br>PDF\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3044\u305f\u3060\u304f\u3068\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb\u306a\u3089\u3073\u306b\u5206\u6790\u6761\u4ef6\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1250.png\" alt=\"Semivolatiles on RMX-5Sil MS by Method 8270D (GC-MS in Scan Mode)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1250<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32460<\/li><li>32459<\/li><li>31909<\/li><li>31879<\/li><li>31850<\/li><li>31806<\/li><li>31025<\/li><li>31024<\/li><li>31886<\/li><li>17323<\/li><li>23303<\/li><li>31907<\/li><li>32460<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>8270<\/li><li>8270D<\/li><li>8270E<\/li><li>RMX-library<\/li><li>SVOC<\/li><li>environmental<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1250.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div><\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"margin-top:0px;margin-bottom:0px\">Scan\u30e2\u30fc\u30c9\uff1a165\u6210\u5206\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb<\/p>\n\n\n\n<style>\n\/* ===============================\n   Keep existing \"analysis table\" centering (as-is)\n   =============================== *\/\n.ac-table-wrap{\n  margin-left: auto !important;\n  margin-right: auto !important;\n}\ntable.ac-table{\n  margin-left: auto !important;\n  margin-right: auto !important;\n}\n\n\/* ===============================\n   GC responsive grid (robust version)\n   - Default: 3 columns\n   - Medium: 2 columns\n   - Small: 1 column\n   - PLUS: container-query fallback when block is inside a narrow column\n   =============================== *\/\n*{ box-sizing: border-box; }\n\n.gc3-wrap{\n  margin: 0 auto;\n  max-width: 1400px;\n  width: 100%;\n  \/* enable container query for \"this block becomes narrow\" cases *\/\n  container-type: inline-size;\n  container-name: gcwrap;\n}\n\n\/* Grid *\/\n.gc3-grid{\n  display: grid;\n  grid-template-columns: repeat(3, minmax(0, 1fr));\n  gap: 18px;\n  font-family: Arial, Helvetica, sans-serif;\n}\n\n\/* ---- Screen-width responsive (most sites) ---- *\/\n\/* 3 -> 2 columns when screen is not wide enough *\/\n@media (max-width: 1100px){\n  .gc3-grid{ grid-template-columns: repeat(2, minmax(0, 1fr)); }\n}\n\/* 2 -> 1 column on phones *\/\n@media (max-width: 720px){\n  .gc3-grid{ grid-template-columns: 1fr; }\n}\n\n\/* ---- Container query (when page has sidebars \/ narrow content area) ---- *\/\n\/* If the container itself is narrow, collapse regardless of screen width *\/\n@container gcwrap (max-width: 1100px){\n  .gc3-grid{ grid-template-columns: repeat(2, minmax(0, 1fr)); }\n}\n@container gcwrap (max-width: 720px){\n  .gc3-grid{ grid-template-columns: 1fr; }\n}\n\n\/* ===============================\n   Table appearance\n   =============================== *\/\ntable.gc3-table{\n  width: 100%;\n  border-collapse: collapse;\n  font-size: 13px;\n  border: 1px solid #b7b7b7;\n  table-layout: fixed;\n  background: #ffffff;\n}\n\n.gc3-table th,\n.gc3-table td{\n  border: 1px solid #b7b7b7;\n  padding: 6px 8px;\n  line-height: 1.25;\n  vertical-align: middle;\n}\n\n.gc3-table thead th{\n  background: #0b2a56;\n  color: #ffffff;\n  font-weight: 700;\n  text-align: left;\n  white-space: nowrap;\n}\n\n.gc3-table tbody tr:nth-child(even){ background: #f2f4f7; }\n\n.gc3-num{\n  text-align: right;\n  font-variant-numeric: tabular-nums;\n  white-space: nowrap;\n}\n\n.gc3-comp{\n  white-space: normal;\n  overflow-wrap: anywhere;\n  word-break: normal;\n}\n\n\/* column widths *\/\n.gc3-table th:nth-child(1), .gc3-table td:nth-child(1){ width: 62px; }\n.gc3-table th:nth-child(3), .gc3-table td:nth-child(3){ width: 86px; }\n.gc3-table th:nth-child(4), .gc3-table td:nth-child(4){ width: 110px; }\n<\/style>\n\n<div class=\"gc3-wrap\">\n  <div class=\"gc3-grid\">\n\n    <!-- ===== Table 1: Peaks 1\u201355 ===== -->\n    <table class=\"gc3-table\">\n      <thead>\n        <tr>\n          <th>Peak<\/th>\n          <th>Compound<\/th>\n          <th>tR (min)<\/th>\n          <th>Conc.<br>(&micro;g\/mL)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td class=\"gc3-num\">1<\/td><td class=\"gc3-comp\">1,4-Dioxane-d8<\/td><td class=\"gc3-num\">2.400<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">2<\/td><td class=\"gc3-comp\">1,4-Dioxane<\/td><td class=\"gc3-num\">2.428<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">3<\/td><td class=\"gc3-comp\">N-Nitrosodimethylamine<\/td><td class=\"gc3-num\">2.702<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">4<\/td><td class=\"gc3-comp\">Pyridine<\/td><td class=\"gc3-num\">2.774<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">5<\/td><td class=\"gc3-comp\">Ethyl methacrylate<\/td><td class=\"gc3-num\">3.175<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">6<\/td><td class=\"gc3-comp\">2-Picoline<\/td><td class=\"gc3-num\">3.554<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">7<\/td><td class=\"gc3-comp\">N-Nitrosomethylethylamine<\/td><td class=\"gc3-num\">3.648<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">8<\/td><td class=\"gc3-comp\">Methyl methanesulfonate<\/td><td class=\"gc3-num\">4.021<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">9<\/td><td class=\"gc3-comp\">2-Fluorophenol<\/td><td class=\"gc3-num\">4.258<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">10<\/td><td class=\"gc3-comp\">Acrylamide<\/td><td class=\"gc3-num\">4.543<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">11<\/td><td class=\"gc3-comp\">N-Nitrosodiethylamine<\/td><td class=\"gc3-num\">4.875<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">12<\/td><td class=\"gc3-comp\">Ethyl methanesulfonate<\/td><td class=\"gc3-num\">4.977<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">13<\/td><td class=\"gc3-comp\">Benzaldehyde<\/td><td class=\"gc3-num\">5.454<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">14<\/td><td class=\"gc3-comp\">Phenol-d6<\/td><td class=\"gc3-num\">5.612<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">15<\/td><td class=\"gc3-comp\">Phenol<\/td><td class=\"gc3-num\">5.629<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">16<\/td><td class=\"gc3-comp\">Aniline<\/td><td class=\"gc3-num\">5.638<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">17<\/td><td class=\"gc3-comp\">Pentachloroethane<\/td><td class=\"gc3-num\">5.705<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">18<\/td><td class=\"gc3-comp\">Bis(2-chloroethyl)ether<\/td><td class=\"gc3-num\">5.743<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">19<\/td><td class=\"gc3-comp\">2-Chlorophenol<\/td><td class=\"gc3-num\">5.814<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">20<\/td><td class=\"gc3-comp\">n-Decane (C10)<\/td><td class=\"gc3-num\">5.962<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">21<\/td><td class=\"gc3-comp\">1,3-Dichlorobenzene<\/td><td class=\"gc3-num\">6.066<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">22<\/td><td class=\"gc3-comp\">1,4-Dichlorobenzene-d4<\/td><td class=\"gc3-num\">6.153<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">23<\/td><td class=\"gc3-comp\">1,4-Dichlorobenzene<\/td><td class=\"gc3-num\">6.180<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">24<\/td><td class=\"gc3-comp\">Benzyl alcohol<\/td><td class=\"gc3-num\">6.393<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">25<\/td><td class=\"gc3-comp\">1,2-Dichlorobenzene<\/td><td class=\"gc3-num\">6.426<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">26<\/td><td class=\"gc3-comp\">2-Methylphenol (o-cresol)<\/td><td class=\"gc3-num\">6.612<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">27<\/td><td class=\"gc3-comp\">2,2&#8242;-Oxybis(1-chloropropane)<\/td><td class=\"gc3-num\">6.634<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">28<\/td><td class=\"gc3-comp\">N-Nitrosopyrrolidine<\/td><td class=\"gc3-num\">6.765<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">29<\/td><td class=\"gc3-comp\">Acetophenone<\/td><td class=\"gc3-num\">6.825<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">30<\/td><td class=\"gc3-comp\">N-Nitrosomorpholine<\/td><td class=\"gc3-num\">6.836<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">31<\/td><td class=\"gc3-comp\">N-Nitroso-di-n-propylamine<\/td><td class=\"gc3-num\">6.847<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">32<\/td><td class=\"gc3-comp\">3-Methylphenol (m-cresol)<\/td><td class=\"gc3-num\">6.885<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">33<\/td><td class=\"gc3-comp\">4-Methylphenol (p-cresol)<\/td><td class=\"gc3-num\">6.885<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">34<\/td><td class=\"gc3-comp\">Indene<\/td><td class=\"gc3-num\">6.885<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">35<\/td><td class=\"gc3-comp\">o-Toluidine<\/td><td class=\"gc3-num\">6.890<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">36<\/td><td class=\"gc3-comp\">Hexachloroethane<\/td><td class=\"gc3-num\">6.989<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">37<\/td><td class=\"gc3-comp\">Nitrobenzene-d5<\/td><td class=\"gc3-num\">7.067<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">38<\/td><td class=\"gc3-comp\">Nitrobenzene<\/td><td class=\"gc3-num\">7.101<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">39<\/td><td class=\"gc3-comp\">N-Nitrosopiperidine<\/td><td class=\"gc3-num\">7.347<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">40<\/td><td class=\"gc3-comp\">Isophorone<\/td><td class=\"gc3-num\">7.536<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">41<\/td><td class=\"gc3-comp\">2-Nitrophenol<\/td><td class=\"gc3-num\">7.673<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">42<\/td><td class=\"gc3-comp\">2,4-Dimethylphenol<\/td><td class=\"gc3-num\">7.816<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">43<\/td><td class=\"gc3-comp\">Benzoic acid<\/td><td class=\"gc3-num\">7.943<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">44<\/td><td class=\"gc3-comp\">O,O,O-Triethyl phosphorothioate<\/td><td class=\"gc3-num\">7.943<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">45<\/td><td class=\"gc3-comp\">Bis(2-chloroethoxy)methane<\/td><td class=\"gc3-num\">7.970<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">46<\/td><td class=\"gc3-comp\">2,4-Dichlorophenol<\/td><td class=\"gc3-num\">8.113<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">47<\/td><td class=\"gc3-comp\">&alpha;,&alpha;-Dimethylphenethylamine (phentermine)<\/td><td class=\"gc3-num\">8.268<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">48<\/td><td class=\"gc3-comp\">1,2,4-Trichlorobenzene<\/td><td class=\"gc3-num\">8.268<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">49<\/td><td class=\"gc3-comp\">Naphthalene-d8<\/td><td class=\"gc3-num\">8.342<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">50<\/td><td class=\"gc3-comp\">Naphthalene<\/td><td class=\"gc3-num\">8.376<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">51<\/td><td class=\"gc3-comp\">&alpha;-Terpineol<\/td><td class=\"gc3-num\">8.451<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">52<\/td><td class=\"gc3-comp\">4-Chloroaniline<\/td><td class=\"gc3-num\">8.519<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">53<\/td><td class=\"gc3-comp\">2,6-Dichlorophenol<\/td><td class=\"gc3-num\">8.519<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">54<\/td><td class=\"gc3-comp\">Hexachloropropene<\/td><td class=\"gc3-num\">8.571<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">55<\/td><td class=\"gc3-comp\">Hexachlorobutadiene<\/td><td class=\"gc3-num\">8.674<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <!-- ===== Table 2: Peaks 56\u2013110 ===== -->\n    <table class=\"gc3-table\">\n      <thead>\n        <tr>\n          <th>Peak<\/th>\n          <th>Compound<\/th>\n          <th>tR (min)<\/th>\n          <th>Conc.<br>(&micro;g\/mL)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td class=\"gc3-num\">56<\/td><td class=\"gc3-comp\">Quinoline<\/td><td class=\"gc3-num\">8.988<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">57<\/td><td class=\"gc3-comp\">&epsilon;-Caprolactam<\/td><td class=\"gc3-num\">9.085<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">58<\/td><td class=\"gc3-comp\">1,4-Phenylenediamine<\/td><td class=\"gc3-num\">9.160<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">59<\/td><td class=\"gc3-comp\">N-Nitrosodibutylamine<\/td><td class=\"gc3-num\">9.195<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">60<\/td><td class=\"gc3-comp\">4-Chloro-3-methylphenol<\/td><td class=\"gc3-num\">9.480<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">61<\/td><td class=\"gc3-comp\">Isosafrole isomer 2<\/td><td class=\"gc3-num\">9.560<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">62<\/td><td class=\"gc3-comp\">2-Methylnaphthalene<\/td><td class=\"gc3-num\">9.680<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">63<\/td><td class=\"gc3-comp\">1-Methylnaphthalene<\/td><td class=\"gc3-num\">9.857<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">64<\/td><td class=\"gc3-comp\">1,2,4,5-Tetrachlorobenzene<\/td><td class=\"gc3-num\">10.023<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">65<\/td><td class=\"gc3-comp\">Hexachlorocyclopentadiene<\/td><td class=\"gc3-num\">10.023<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">66<\/td><td class=\"gc3-comp\">2,3-Dichloroaniline<\/td><td class=\"gc3-num\">10.217<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">67<\/td><td class=\"gc3-comp\">Isosafrole isomer 1<\/td><td class=\"gc3-num\">10.217<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">68<\/td><td class=\"gc3-comp\">2,4,6-Trichlorophenol<\/td><td class=\"gc3-num\">10.248<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">69<\/td><td class=\"gc3-comp\">2,4,5-Trichlorophenol<\/td><td class=\"gc3-num\">10.303<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">70<\/td><td class=\"gc3-comp\">2-Fluorobiphenyl<\/td><td class=\"gc3-num\">10.412<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">71<\/td><td class=\"gc3-comp\">Safrole<\/td><td class=\"gc3-num\">10.547<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">72<\/td><td class=\"gc3-comp\">Biphenyl<\/td><td class=\"gc3-num\">10.585<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">73<\/td><td class=\"gc3-comp\">2-Chloronaphthalene<\/td><td class=\"gc3-num\">10.585<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">74<\/td><td class=\"gc3-comp\">1-Chloronaphthalene<\/td><td class=\"gc3-num\">10.623<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">75<\/td><td class=\"gc3-comp\">2-Nitroaniline<\/td><td class=\"gc3-num\">10.801<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">76<\/td><td class=\"gc3-comp\">Diphenyl ether<\/td><td class=\"gc3-num\">10.801<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">77<\/td><td class=\"gc3-comp\">1,4-Naphthoquinone<\/td><td class=\"gc3-num\">10.926<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">78<\/td><td class=\"gc3-comp\">1,4-Dinitrobenzene<\/td><td class=\"gc3-num\">11.075<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">79<\/td><td class=\"gc3-comp\">Dimethylphthalate<\/td><td class=\"gc3-num\">11.224<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">80<\/td><td class=\"gc3-comp\">1,3-Dinitrobenzene<\/td><td class=\"gc3-num\">11.304<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">81<\/td><td class=\"gc3-comp\">2,6-Dinitrotoluene<\/td><td class=\"gc3-num\">11.304<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">82<\/td><td class=\"gc3-comp\">1,2-Dinitrobenzene<\/td><td class=\"gc3-num\">11.361<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">83<\/td><td class=\"gc3-comp\">Acenaphthylene<\/td><td class=\"gc3-num\">11.361<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">84<\/td><td class=\"gc3-comp\">3-Nitroaniline<\/td><td class=\"gc3-num\">11.595<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">85<\/td><td class=\"gc3-comp\">Acenaphthene-d10<\/td><td class=\"gc3-num\">11.647<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">86<\/td><td class=\"gc3-comp\">Acenaphthene<\/td><td class=\"gc3-num\">11.704<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">87<\/td><td class=\"gc3-comp\">2,4-Dinitrophenol<\/td><td class=\"gc3-num\">11.809<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">88<\/td><td class=\"gc3-comp\">4-Nitrophenol<\/td><td class=\"gc3-num\">11.996<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">89<\/td><td class=\"gc3-comp\">Pentachlorobenzene<\/td><td class=\"gc3-num\">11.996<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">90<\/td><td class=\"gc3-comp\">Dibenzofuran<\/td><td class=\"gc3-num\">12.040<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">91<\/td><td class=\"gc3-comp\">2,4-Dinitrotoluene<\/td><td class=\"gc3-num\">12.070<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">92<\/td><td class=\"gc3-comp\">1-Naphthylamine (1-aminonaphthalene)<\/td><td class=\"gc3-num\">12.184<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">93<\/td><td class=\"gc3-comp\">2,3,5,6-Tetrachlorophenol<\/td><td class=\"gc3-num\">12.236<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">94<\/td><td class=\"gc3-comp\">2,3,4,6-Tetrachlorophenol<\/td><td class=\"gc3-num\">12.319<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">95<\/td><td class=\"gc3-comp\">2-Naphthylamine (2-aminonaphthalene)<\/td><td class=\"gc3-num\">12.341<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">96<\/td><td class=\"gc3-comp\">Diethylphthalate<\/td><td class=\"gc3-num\">12.602<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">97<\/td><td class=\"gc3-comp\">n-Hexadecane (C16)<\/td><td class=\"gc3-num\">12.699<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">98<\/td><td class=\"gc3-comp\">Fluorene<\/td><td class=\"gc3-num\">12.699<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">99<\/td><td class=\"gc3-comp\">Zalophus (thionazine)<\/td><td class=\"gc3-num\">12.745<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">100<\/td><td class=\"gc3-comp\">4-Chlorophenyl phenyl ether<\/td><td class=\"gc3-num\">12.745<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">101<\/td><td class=\"gc3-comp\">4-Nitroaniline<\/td><td class=\"gc3-num\">12.745<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">102<\/td><td class=\"gc3-comp\">5-Nitro-o-toluidine<\/td><td class=\"gc3-num\">12.745<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">103<\/td><td class=\"gc3-comp\">4,6-Dinitro-2-methylphenol (Dinitro-o-cresol)<\/td><td class=\"gc3-num\">12.853<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">104<\/td><td class=\"gc3-comp\">Diphenylamine&#8224;<\/td><td class=\"gc3-num\">12.979<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">105<\/td><td class=\"gc3-comp\">Azobenzene*<\/td><td class=\"gc3-num\">13.042<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">106<\/td><td class=\"gc3-comp\">2,4,6-Tribromophenol<\/td><td class=\"gc3-num\">13.162<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">107<\/td><td class=\"gc3-comp\">Sulfotepp<\/td><td class=\"gc3-num\">13.379<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">108<\/td><td class=\"gc3-comp\">1,3,5-Trinitrobenzene<\/td><td class=\"gc3-num\">13.579<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">109<\/td><td class=\"gc3-comp\">Phorate<\/td><td class=\"gc3-num\">13.579<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">110<\/td><td class=\"gc3-comp\">Phenacetin<\/td><td class=\"gc3-num\">13.625<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n    <!-- ===== Table 3: Peaks 111\u2013165 ===== -->\n    <table class=\"gc3-table\">\n      <thead>\n        <tr>\n          <th>Peak<\/th>\n          <th>Compound<\/th>\n          <th>tR (min)<\/th>\n          <th>Conc.<br>(&micro;g\/mL)<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr><td class=\"gc3-num\">111<\/td><td class=\"gc3-comp\">4-Bromophenyl phenyl ether<\/td><td class=\"gc3-num\">13.677<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">112<\/td><td class=\"gc3-comp\">Diallate<\/td><td class=\"gc3-num\">13.734<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">113<\/td><td class=\"gc3-comp\">Hexachlorobenzene<\/td><td class=\"gc3-num\">13.785<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">114<\/td><td class=\"gc3-comp\">Dimethoate<\/td><td class=\"gc3-num\">13.865<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">115<\/td><td class=\"gc3-comp\">Atrazine<\/td><td class=\"gc3-num\">14.071<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">116<\/td><td class=\"gc3-comp\">4-Aminobiphenyl<\/td><td class=\"gc3-num\">14.168<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">117<\/td><td class=\"gc3-comp\">Pentachlorophenol<\/td><td class=\"gc3-num\">14.170<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">118<\/td><td class=\"gc3-comp\">Pentachloronitrobenzene (Quintozene)<\/td><td class=\"gc3-num\">14.214<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">119<\/td><td class=\"gc3-comp\">Propyzamide<\/td><td class=\"gc3-num\">14.380<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">120<\/td><td class=\"gc3-comp\">Phenanthrene-d10<\/td><td class=\"gc3-num\">14.477<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">121<\/td><td class=\"gc3-comp\">n-Octadecane (C18)<\/td><td class=\"gc3-num\">14.517<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">122<\/td><td class=\"gc3-comp\">Phenanthrene<\/td><td class=\"gc3-num\">14.517<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">123<\/td><td class=\"gc3-comp\">Dinoseb<\/td><td class=\"gc3-num\">14.599<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">124<\/td><td class=\"gc3-comp\">Disulfoton<\/td><td class=\"gc3-num\">14.599<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">125<\/td><td class=\"gc3-comp\">Anthracene<\/td><td class=\"gc3-num\">14.614<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">126<\/td><td class=\"gc3-comp\">Carbazole<\/td><td class=\"gc3-num\">14.963<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">127<\/td><td class=\"gc3-comp\">Methyl parathion<\/td><td class=\"gc3-num\">15.295<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">128<\/td><td class=\"gc3-comp\">Di-n-butyl phthalate<\/td><td class=\"gc3-num\">15.775<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">129<\/td><td class=\"gc3-comp\">4-Nitroquinoline-N-oxide<\/td><td class=\"gc3-num\">16.027<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">130<\/td><td class=\"gc3-comp\">Parathion (ethyl parathion)<\/td><td class=\"gc3-num\">16.078<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">131<\/td><td class=\"gc3-comp\">Methapyrilene hydrochloride<\/td><td class=\"gc3-num\">16.273<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">132<\/td><td class=\"gc3-comp\">Isodrin<\/td><td class=\"gc3-num\">16.518<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">133<\/td><td class=\"gc3-comp\">Fluoranthene<\/td><td class=\"gc3-num\">16.804<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">134<\/td><td class=\"gc3-comp\">Benzidine<\/td><td class=\"gc3-num\">17.127<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">135<\/td><td class=\"gc3-comp\">Pyrene<\/td><td class=\"gc3-num\">17.222<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">136<\/td><td class=\"gc3-comp\">p-Terphenyl-d14<\/td><td class=\"gc3-num\">17.622<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">137<\/td><td class=\"gc3-comp\">Aramite isomer 2<\/td><td class=\"gc3-num\">17.668<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">138<\/td><td class=\"gc3-comp\">Aramite isomer 1<\/td><td class=\"gc3-num\">17.822<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">139<\/td><td class=\"gc3-comp\">p-Dimethylaminoazobenzene<\/td><td class=\"gc3-num\">17.908<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">140<\/td><td class=\"gc3-comp\">Chlorobenzilate<\/td><td class=\"gc3-num\">18.034<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">141<\/td><td class=\"gc3-comp\">Famphur<\/td><td class=\"gc3-num\">18.485<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">142<\/td><td class=\"gc3-comp\">3,3&#8242;-Dimethylbenzidine (o-tolidine)<\/td><td class=\"gc3-num\">18.548<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">143<\/td><td class=\"gc3-comp\">Kepone<\/td><td class=\"gc3-num\">18.548<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">144<\/td><td class=\"gc3-comp\">Benzyl butyl phthalate<\/td><td class=\"gc3-num\">18.640<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">145<\/td><td class=\"gc3-comp\">Bis(2-ethylhexyl)adipate<\/td><td class=\"gc3-num\">18.891<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">146<\/td><td class=\"gc3-comp\">2-Acetylaminofluorene<\/td><td class=\"gc3-num\">19.017<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">147<\/td><td class=\"gc3-comp\">4,4&#8242;-Methylene-bis(2-chloroaniline)<\/td><td class=\"gc3-num\">19.108<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">148<\/td><td class=\"gc3-comp\">3,3&#8242;-Dichlorobenzidine<\/td><td class=\"gc3-num\">19.560<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">149<\/td><td class=\"gc3-comp\">Benz[a]anthracene<\/td><td class=\"gc3-num\">19.560<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">150<\/td><td class=\"gc3-comp\">Chrysene-d12<\/td><td class=\"gc3-num\">19.560<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">151<\/td><td class=\"gc3-comp\">Chrysene<\/td><td class=\"gc3-num\">19.612<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">152<\/td><td class=\"gc3-comp\">Bis(2-ethylhexyl)phthalate<\/td><td class=\"gc3-num\">19.823<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">153<\/td><td class=\"gc3-comp\">6-Methylchrysene<\/td><td class=\"gc3-num\">20.475<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">154<\/td><td class=\"gc3-comp\">Di-n-octyl phthalate<\/td><td class=\"gc3-num\">21.030<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">155<\/td><td class=\"gc3-comp\">Benzo[b]fluoranthene<\/td><td class=\"gc3-num\">21.590<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">156<\/td><td class=\"gc3-comp\">7,12-Dimethylbenz[a]anthracene<\/td><td class=\"gc3-num\">21.590<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">157<\/td><td class=\"gc3-comp\">Benzo[k]fluoranthene<\/td><td class=\"gc3-num\">21.641<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">158<\/td><td class=\"gc3-comp\">Benzo[a]pyrene<\/td><td class=\"gc3-num\">22.248<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">159<\/td><td class=\"gc3-comp\">Perylene-d12<\/td><td class=\"gc3-num\">22.379<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">160<\/td><td class=\"gc3-comp\">3-Methylcholanthrene<\/td><td class=\"gc3-num\">23.082<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n\n        <tr><td class=\"gc3-num\">161<\/td><td class=\"gc3-comp\">Dibenz(a,h)acridine<\/td><td class=\"gc3-num\">24.357<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">162<\/td><td class=\"gc3-comp\">Dibenz[a,j]acridine<\/td><td class=\"gc3-num\">24.483<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">163<\/td><td class=\"gc3-comp\">Indeno[1,2,3-cd]pyrene<\/td><td class=\"gc3-num\">24.883<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">164<\/td><td class=\"gc3-comp\">Dibenz[a,h]anthracene<\/td><td class=\"gc3-num\">24.969<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n        <tr><td class=\"gc3-num\">165<\/td><td class=\"gc3-comp\">Benzo[g,h,i]perylene<\/td><td class=\"gc3-num\">25.541<\/td><td class=\"gc3-num\">1<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n\n  <\/div>\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image69290_b02a92-50.kb-image-is-ratio-size, .kb-image69290_b02a92-50 .kb-image-is-ratio-size{max-width:800px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image69290_b02a92-50.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image69290_b02a92-50 .kb-image-is-ratio-size{align-self:unset;}.kb-image69290_b02a92-50 figure{max-width:800px;}.kb-image69290_b02a92-50 .image-is-svg, .kb-image69290_b02a92-50 .image-is-svg img{width:100%;}.kb-image69290_b02a92-50:not(.kb-image-is-ratio-size) .kb-img, .kb-image69290_b02a92-50.kb-image-is-ratio-size{padding-right:50px;padding-left:50px;}.kb-image69290_b02a92-50 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image69290_b02a92-50\"><figure class=\"aligncenter size-full\"><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3445-ja\/ezgc-online-tools-japan\" class=\"kb-advanced-image-link\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"312\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-1.png\" alt=\"\" class=\"kb-img wp-image-79633\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-1.png 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-1-300x70.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-1-1024x238.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-1-768x179.png 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-0bd16b36 wp-block-columns-is-layout-flex\" style=\"padding-right:100px;padding-left:100px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-theme-palette-7-background-color has-background has-medium-font-size wp-block-paragraph\" style=\"border-radius:10px;margin-top:-2px;margin-bottom:-2px;padding-right:2px;padding-left:2px\"><strong>Figure 2. SIM Mode (200 pg on-column)<\/strong><br>PDF\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3044\u305f\u3060\u304f\u3068\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb\u306a\u3089\u3073\u306b\u5206\u6790\u6761\u4ef6\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1251.png\" alt=\"Semivolatiles on RMX-5Sil MS by 8270D (GC-MS in SIM Mode)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_GN1251<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>32460<\/li><li>32459<\/li><li>31909<\/li><li>31879<\/li><li>31850<\/li><li>31806<\/li><li>31025<\/li><li>31024<\/li><li>31886<\/li><li>17323<\/li><li>23303<\/li><li>31907<\/li><li>32460<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>8270<\/li><li>8270D<\/li><li>RMX-library<\/li><li>SVOC<\/li><li>enviromental&#039;<\/li><li>semivolatiles<\/li><li>semivolatiles-gc-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_gn1251.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div><\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"margin-top:0px;margin-bottom:0px\">SIM\u30e2\u30fc\u30c9\uff1a165\u6210\u5206\u306e\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb<\/p>\n\n\n\n<style>\n  .gc-table-grid{\n    max-width: 1200px;\n    margin: 0 auto;\n    display: grid;\n    grid-template-columns: 1fr 1fr;\n    gap: 24px;\n    font-family: Arial, Helvetica, sans-serif;\n  }\n  @media (max-width: 900px){\n    .gc-table-grid{ grid-template-columns: 1fr; }\n  }\n  table.gc-table{\n    width: 100%;\n    border-collapse: collapse;\n    font-size: 13px;\n    border: 1px solid #b7b7b7;\n  }\n  .gc-table th,\n  .gc-table td{\n    border: 1px solid #b7b7b7;\n    padding: 6px 8px;\n    line-height: 1.25;\n    vertical-align: middle;\n  }\n  .gc-table thead th{\n    background: #0b2a56;\n    color: #ffffff;\n    font-weight: 700;\n    text-align: left;\n    white-space: nowrap;\n  }\n  .gc-table tbody tr:nth-child(even){ background: #f2f4f7; }\n  .num{\n    text-align: right;\n    font-variant-numeric: tabular-nums;\n    white-space: nowrap;\n  }\n  .center{ text-align: center; white-space: nowrap; }\n<\/style>\n\n<div class=\"gc-table-grid\">\n\n  <!-- ===== Left table: Peaks 1\u201382 ===== -->\n  <table class=\"gc-table\">\n    <thead>\n      <tr>\n        <th>Peak<\/th>\n        <th>Compound<\/th>\n        <th>tR (min)<\/th>\n        <th>Conc.<br>(ng\/mL)<\/th>\n        <th>SIM Ion<\/th>\n        <th>Dwell<br>(ms)<\/th>\n        <th>Ion<br>Group<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr><td class=\"num\">1<\/td><td>1,4-Dioxane-d8<\/td><td class=\"num\">2.401<\/td><td class=\"num\">200<\/td><td class=\"num\">96<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">2<\/td><td>1,4-Dioxane<\/td><td class=\"num\">2.427<\/td><td class=\"num\">200<\/td><td class=\"num\">88<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">3<\/td><td>N-Nitrosodimethylamine<\/td><td class=\"num\">2.702<\/td><td class=\"num\">200<\/td><td class=\"num\">74<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">4<\/td><td>Pyridine<\/td><td class=\"num\">2.774<\/td><td class=\"num\">200<\/td><td class=\"num\">79<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">5<\/td><td>Ethyl methacrylate<\/td><td class=\"num\">3.175<\/td><td class=\"num\">200<\/td><td class=\"num\">69<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">6<\/td><td>2-Picoline<\/td><td class=\"num\">3.554<\/td><td class=\"num\">200<\/td><td class=\"num\">93<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">7<\/td><td>N-Nitrosomethylethylamine<\/td><td class=\"num\">3.648<\/td><td class=\"num\">200<\/td><td class=\"num\">42<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">8<\/td><td>Methyl methanesulfonate<\/td><td class=\"num\">4.021<\/td><td class=\"num\">200<\/td><td class=\"num\">80<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">9<\/td><td>2-Fluorophenol<\/td><td class=\"num\">4.258<\/td><td class=\"num\">200<\/td><td class=\"num\">112<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">10<\/td><td>Acrylamide<\/td><td class=\"num\">4.543<\/td><td class=\"num\">200<\/td><td class=\"num\">71<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n\n      <tr><td class=\"num\">11<\/td><td>N-Nitrosodiethylamine<\/td><td class=\"num\">4.977<\/td><td class=\"num\">200<\/td><td class=\"num\">102<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">12<\/td><td>Ethyl methanesulfonate<\/td><td class=\"num\">4.977<\/td><td class=\"num\">200<\/td><td class=\"num\">109<\/td><td class=\"num\">25<\/td><td class=\"center\">1<\/td><\/tr>\n      <tr><td class=\"num\">13<\/td><td>Benzaldehyde<\/td><td class=\"num\">5.454<\/td><td class=\"num\">200<\/td><td class=\"num\">77<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">14<\/td><td>Phenol-d6<\/td><td class=\"num\">5.612<\/td><td class=\"num\">200<\/td><td class=\"num\">99<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">15<\/td><td>Phenol<\/td><td class=\"num\">5.633<\/td><td class=\"num\">200<\/td><td class=\"num\">94<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">16<\/td><td>Aniline<\/td><td class=\"num\">5.633<\/td><td class=\"num\">200<\/td><td class=\"num\">93<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">17<\/td><td>Pentachloroethane<\/td><td class=\"num\">5.7<\/td><td class=\"num\">200<\/td><td class=\"num\">167<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">18<\/td><td>Bis(2-chloroethyl)ether<\/td><td class=\"num\">5.743<\/td><td class=\"num\">200<\/td><td class=\"num\">63<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">19<\/td><td>2-Chlorophenol<\/td><td class=\"num\">5.814<\/td><td class=\"num\">200<\/td><td class=\"num\">128<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">20<\/td><td>n-Decane (C10)<\/td><td class=\"num\">5.962<\/td><td class=\"num\">200<\/td><td class=\"num\">57<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n\n      <tr><td class=\"num\">21<\/td><td>1,3-Dichlorobenzene<\/td><td class=\"num\">6.066<\/td><td class=\"num\">200<\/td><td class=\"num\">146<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">22<\/td><td>1,4-Dichlorobenzene-d4<\/td><td class=\"num\">6.154<\/td><td class=\"num\">200<\/td><td class=\"num\">150<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">23<\/td><td>1,4-Dichlorobenzene<\/td><td class=\"num\">6.18<\/td><td class=\"num\">200<\/td><td class=\"num\">148<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">24<\/td><td>Benzyl alcohol<\/td><td class=\"num\">6.393<\/td><td class=\"num\">200<\/td><td class=\"num\">79<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">25<\/td><td>1,2-Dichlorobenzene<\/td><td class=\"num\">6.426<\/td><td class=\"num\">200<\/td><td class=\"num\">111<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">26<\/td><td>2-Methylphenol (o-cresol)<\/td><td class=\"num\">6.611<\/td><td class=\"num\">200<\/td><td class=\"num\">108<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">27<\/td><td>2,2\u2032-Oxybis(1-chloropropane)<\/td><td class=\"num\">6.634<\/td><td class=\"num\">200<\/td><td class=\"num\">45<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">28<\/td><td>N-Nitrosopyrrolidine<\/td><td class=\"num\">6.765<\/td><td class=\"num\">200<\/td><td class=\"num\">100<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">29<\/td><td>Acetophenone<\/td><td class=\"num\">6.825<\/td><td class=\"num\">200<\/td><td class=\"num\">105<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">30<\/td><td>N-Nitrosomorpholine<\/td><td class=\"num\">6.825<\/td><td class=\"num\">200<\/td><td class=\"num\">56<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n\n      <tr><td class=\"num\">31<\/td><td>N-Nitroso-di-n-propylamine<\/td><td class=\"num\">6.825<\/td><td class=\"num\">200<\/td><td class=\"num\">43<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">32<\/td><td>3-Methylphenol (m-cresol)<\/td><td class=\"num\">6.885<\/td><td class=\"num\">200<\/td><td class=\"num\">80<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">33<\/td><td>4-Methylphenol (p-cresol)<\/td><td class=\"num\">6.885<\/td><td class=\"num\">200<\/td><td class=\"num\">107<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">34<\/td><td>Indene<\/td><td class=\"num\">6.885<\/td><td class=\"num\">200<\/td><td class=\"num\">117<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">35<\/td><td>o-Toluidine<\/td><td class=\"num\">6.885<\/td><td class=\"num\">200<\/td><td class=\"num\">106<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">36<\/td><td>Hexachloroethane<\/td><td class=\"num\">6.989<\/td><td class=\"num\">200<\/td><td class=\"num\">119<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">37<\/td><td>Nitrobenzene-d5<\/td><td class=\"num\">7.068<\/td><td class=\"num\">200<\/td><td class=\"num\">82<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">38<\/td><td>Nitrobenzene<\/td><td class=\"num\">7.1<\/td><td class=\"num\">200<\/td><td class=\"num\">123<\/td><td class=\"num\">11<\/td><td class=\"center\">2<\/td><\/tr>\n      <tr><td class=\"num\">39<\/td><td>N-Nitrosopiperidine<\/td><td class=\"num\">7.347<\/td><td class=\"num\">200<\/td><td class=\"num\">114<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">40<\/td><td>Isophorone<\/td><td class=\"num\">7.531<\/td><td class=\"num\">200<\/td><td class=\"num\">82<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n\n      <tr><td class=\"num\">41<\/td><td>2-Nitrophenol<\/td><td class=\"num\">7.671<\/td><td class=\"num\">200<\/td><td class=\"num\">139<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">42<\/td><td>2,4-Dimethylphenol<\/td><td class=\"num\">7.811<\/td><td class=\"num\">200<\/td><td class=\"num\">122<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">43<\/td><td>Benzoic acid<\/td><td class=\"num\">7.898<\/td><td class=\"num\">200<\/td><td class=\"num\">105<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">44<\/td><td>O,O,O-Triethyl phosphorothioate<\/td><td class=\"num\">7.942<\/td><td class=\"num\">200<\/td><td class=\"num\">121<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">45<\/td><td>Bis(2-chloroethoxy)methane<\/td><td class=\"num\">7.969<\/td><td class=\"num\">200<\/td><td class=\"num\">93<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">46<\/td><td>2,4-Dichlorophenol<\/td><td class=\"num\">8.113<\/td><td class=\"num\">200<\/td><td class=\"num\">162<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">47<\/td><td>\u03b1,\u03b1-Dimethylphenethylamine (phentermine)<\/td><td class=\"num\">8.178<\/td><td class=\"num\">200<\/td><td class=\"num\">58<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">48<\/td><td>1,2,4-Trichlorobenzene<\/td><td class=\"num\">8.264<\/td><td class=\"num\">200<\/td><td class=\"num\">180<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">49<\/td><td>Naphthalene-d8<\/td><td class=\"num\">8.34<\/td><td class=\"num\">200<\/td><td class=\"num\">136<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">50<\/td><td>Naphthalene<\/td><td class=\"num\">8.378<\/td><td class=\"num\">200<\/td><td class=\"num\">128<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n\n      <tr><td class=\"num\">51<\/td><td>\u03b1-Terpineol<\/td><td class=\"num\">8.453<\/td><td class=\"num\">200<\/td><td class=\"num\">59<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">52<\/td><td>4-Chloroaniline<\/td><td class=\"num\">8.518<\/td><td class=\"num\">200<\/td><td class=\"num\">127<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">53<\/td><td>2,6-Dichlorophenol<\/td><td class=\"num\">8.518<\/td><td class=\"num\">200<\/td><td class=\"num\">164<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">54<\/td><td>Hexachloropropene<\/td><td class=\"num\">8.572<\/td><td class=\"num\">200<\/td><td class=\"num\">213<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">55<\/td><td>Hexachlorobutadiene<\/td><td class=\"num\">8.674<\/td><td class=\"num\">200<\/td><td class=\"num\">225<\/td><td class=\"num\">17<\/td><td class=\"center\">3<\/td><\/tr>\n      <tr><td class=\"num\">56<\/td><td>Quinoline<\/td><td class=\"num\">8.993<\/td><td class=\"num\">200<\/td><td class=\"num\">129<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">57<\/td><td>\u03b5-Caprolactam<\/td><td class=\"num\">9.085<\/td><td class=\"num\">200<\/td><td class=\"num\">55<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">58<\/td><td>1,4-Phenylenediamine<\/td><td class=\"num\">9.160<\/td><td class=\"num\">200<\/td><td class=\"num\">108<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">59<\/td><td>N-Nitrosodibutylamine<\/td><td class=\"num\">9.195<\/td><td class=\"num\">200<\/td><td class=\"num\">84<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">60<\/td><td>4-Chloro-3-methylphenol<\/td><td class=\"num\">9.477<\/td><td class=\"num\">200<\/td><td class=\"num\">107<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n\n      <tr><td class=\"num\">61<\/td><td>Isosafrole isomer 2<\/td><td class=\"num\">9.563<\/td><td class=\"num\">200<\/td><td class=\"num\">181<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">62<\/td><td>2-Methylnaphthalene<\/td><td class=\"num\">9.681<\/td><td class=\"num\">200<\/td><td class=\"num\">142<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">63<\/td><td>1-Methylnaphthalene<\/td><td class=\"num\">9.858<\/td><td class=\"num\">200<\/td><td class=\"num\">141<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">64<\/td><td>1,2,4,5-Tetrachlorobenzene<\/td><td class=\"num\">10.024<\/td><td class=\"num\">200<\/td><td class=\"num\">216<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">65<\/td><td>Hexachlorocyclopentadiene<\/td><td class=\"num\">10.024<\/td><td class=\"num\">200<\/td><td class=\"num\">237<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">66<\/td><td>2,3-Dichloroaniline<\/td><td class=\"num\">10.221<\/td><td class=\"num\">200<\/td><td class=\"num\">161<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">67<\/td><td>Isosafrole isomer 1<\/td><td class=\"num\">10.221<\/td><td class=\"num\">200<\/td><td class=\"num\">104<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">68<\/td><td>2,4,6-Trichlorophenol<\/td><td class=\"num\">10.25<\/td><td class=\"num\">200<\/td><td class=\"num\">196<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">69<\/td><td>2,4,5-Trichlorophenol<\/td><td class=\"num\">10.303<\/td><td class=\"num\">200<\/td><td class=\"num\">198<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">70<\/td><td>2-Fluorobiphenyl<\/td><td class=\"num\">10.41<\/td><td class=\"num\">200<\/td><td class=\"num\">172<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n\n      <tr><td class=\"num\">71<\/td><td>Safrole<\/td><td class=\"num\">10.549<\/td><td class=\"num\">200<\/td><td class=\"num\">131<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">72<\/td><td>Biphenyl<\/td><td class=\"num\">10.586<\/td><td class=\"num\">200<\/td><td class=\"num\">154<\/td><td class=\"num\">15<\/td><td class=\"center\">4<\/td><\/tr>\n      <tr><td class=\"num\">73<\/td><td>2-Chloronaphthalene<\/td><td class=\"num\">10.586<\/td><td class=\"num\">200<\/td><td class=\"num\">162<\/td><td class=\"num\">15<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">74<\/td><td>1-Chloronaphthalene<\/td><td class=\"num\">10.624<\/td><td class=\"num\">200<\/td><td class=\"num\">127<\/td><td class=\"num\">15<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">75<\/td><td>2-Nitroaniline<\/td><td class=\"num\">10.803<\/td><td class=\"num\">200<\/td><td class=\"num\">138<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">76<\/td><td>Diphenyl ether<\/td><td class=\"num\">10.803<\/td><td class=\"num\">200<\/td><td class=\"num\">170<\/td><td class=\"num\">15<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">77<\/td><td>1,4-Naphthoquinone<\/td><td class=\"num\">10.927<\/td><td class=\"num\">200<\/td><td class=\"num\">158<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">78<\/td><td>1,4-Dinitrobenzene<\/td><td class=\"num\">11.073<\/td><td class=\"num\">200<\/td><td class=\"num\">168<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">79<\/td><td>Dimethylphthalate<\/td><td class=\"num\">11.223<\/td><td class=\"num\">200<\/td><td class=\"num\">163<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">80<\/td><td>1,3-Dinitrobenzene<\/td><td class=\"num\">11.301<\/td><td class=\"num\">200<\/td><td class=\"num\">76<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n\n      <tr><td class=\"num\">81<\/td><td>2,6-Dinitrotoluene<\/td><td class=\"num\">11.301<\/td><td class=\"num\">200<\/td><td class=\"num\">165<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">82<\/td><td>1,2-Dinitrobenzene<\/td><td class=\"num\">11.363<\/td><td class=\"num\">200<\/td><td class=\"num\">50<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n  <!-- ===== Right table: Peaks 83\u2013165 ===== -->\n  <table class=\"gc-table\">\n    <thead>\n      <tr>\n        <th>Peak<\/th>\n        <th>Compound<\/th>\n        <th>tR (min)<\/th>\n        <th>Conc.<br>(ng\/mL)<\/th>\n        <th>SIM Ion<\/th>\n        <th>Dwell<br>(ms)<\/th>\n        <th>Ion<br>Group<\/th>\n      <\/tr>\n    <\/thead>\n    <tbody>\n      <tr><td class=\"num\">83<\/td><td>Acenaphthylene<\/td><td class=\"num\">11.363<\/td><td class=\"num\">200<\/td><td class=\"num\">152<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">84<\/td><td>3-Nitroaniline<\/td><td class=\"num\">11.591<\/td><td class=\"num\">200<\/td><td class=\"num\">65<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">85<\/td><td>Acenaphthene-d10<\/td><td class=\"num\">11.649<\/td><td class=\"num\">200<\/td><td class=\"num\">162<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">86<\/td><td>Acenaphthene<\/td><td class=\"num\">11.706<\/td><td class=\"num\">200<\/td><td class=\"num\">153<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">87<\/td><td>2,4-Dinitrophenol<\/td><td class=\"num\">11.809<\/td><td class=\"num\">200<\/td><td class=\"num\">184<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">88<\/td><td>4-Nitrophenol<\/td><td class=\"num\">11.996<\/td><td class=\"num\">200<\/td><td class=\"num\">139<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">89<\/td><td>Pentachlorobenzene<\/td><td class=\"num\">11.996<\/td><td class=\"num\">200<\/td><td class=\"num\">250<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">90<\/td><td>Dibenzofuran<\/td><td class=\"num\">12.043<\/td><td class=\"num\">200<\/td><td class=\"num\">84<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n\n      <tr><td class=\"num\">91<\/td><td>2,4-Dinitrotoluene<\/td><td class=\"num\">12.183<\/td><td class=\"num\">200<\/td><td class=\"num\">89<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">92<\/td><td>1-Naphthylamine (1-aminonaphthalene)<\/td><td class=\"num\">12.235<\/td><td class=\"num\">200<\/td><td class=\"num\">143<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">93<\/td><td>2,3,5,6-Tetrachlorophenol<\/td><td class=\"num\">12.339<\/td><td class=\"num\">200<\/td><td class=\"num\">232<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">94<\/td><td>2,3,4,6-Tetrachlorophenol<\/td><td class=\"num\">12.339<\/td><td class=\"num\">200<\/td><td class=\"num\">230<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">95<\/td><td>2-Naphthylamine (2-aminonaphthalene)<\/td><td class=\"num\">12.339<\/td><td class=\"num\">200<\/td><td class=\"num\">115<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">96<\/td><td>Diethylphthalate<\/td><td class=\"num\">12.596<\/td><td class=\"num\">200<\/td><td class=\"num\">149<\/td><td class=\"num\">13<\/td><td class=\"center\">5<\/td><\/tr>\n      <tr><td class=\"num\">97<\/td><td>n-Hexadecane (C16)<\/td><td class=\"num\">12.703<\/td><td class=\"num\">200<\/td><td class=\"num\">57<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n      <tr><td class=\"num\">98<\/td><td>Fluorene<\/td><td class=\"num\">12.703<\/td><td class=\"num\">200<\/td><td class=\"num\">166<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n      <tr><td class=\"num\">99<\/td><td>Zalophus (thionazine)<\/td><td class=\"num\">12.746<\/td><td class=\"num\">200<\/td><td class=\"num\">107<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n      <tr><td class=\"num\">100<\/td><td>4-Chlorophenyl phenyl ether<\/td><td class=\"num\">12.746<\/td><td class=\"num\">200<\/td><td class=\"num\">204<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n\n      <tr><td class=\"num\">101<\/td><td>4-Nitroaniline<\/td><td class=\"num\">12.746<\/td><td class=\"num\">200<\/td><td class=\"num\">65<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n      <tr><td class=\"num\">102<\/td><td>5-Nitro-o-toluidine<\/td><td class=\"num\">12.746<\/td><td class=\"num\">200<\/td><td class=\"num\">152<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n      <tr><td class=\"num\">103<\/td><td>4,6-Dinitro-2-methylphenol (Dinitro-o-cresol)<\/td><td class=\"num\">12.852<\/td><td class=\"num\">200<\/td><td class=\"num\">198<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n      <tr><td class=\"num\">104<\/td><td>Diphenylamine\u2020<\/td><td class=\"num\">12.98<\/td><td class=\"num\">200<\/td><td class=\"num\">169<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n      <tr><td class=\"num\">105<\/td><td>Azobenzene*<\/td><td class=\"num\">13.044<\/td><td class=\"num\">200<\/td><td class=\"num\">77<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n      <tr><td class=\"num\">106<\/td><td>2,4,6-Tribromophenol<\/td><td class=\"num\">13.162<\/td><td class=\"num\">200<\/td><td class=\"num\">330<\/td><td class=\"num\">29<\/td><td class=\"center\">6<\/td><\/tr>\n      <tr><td class=\"num\">107<\/td><td>Sulfotepp<\/td><td class=\"num\">13.385<\/td><td class=\"num\">200<\/td><td class=\"num\">322<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">108<\/td><td>1,3,5-Trinitrobenzene<\/td><td class=\"num\">13.581<\/td><td class=\"num\">200<\/td><td class=\"num\">213<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">109<\/td><td>Phenacetin<\/td><td class=\"num\">13.581<\/td><td class=\"num\">200<\/td><td class=\"num\">108<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">110<\/td><td>Phorate<\/td><td class=\"num\">13.618<\/td><td class=\"num\">200<\/td><td class=\"num\">75<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n\n      <tr><td class=\"num\">111<\/td><td>4-Bromophenyl phenyl ether<\/td><td class=\"num\">13.677<\/td><td class=\"num\">200<\/td><td class=\"num\">248<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">112<\/td><td>Diallate<\/td><td class=\"num\">13.735<\/td><td class=\"num\">200<\/td><td class=\"num\">43<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">113<\/td><td>Hexachlorobenzene<\/td><td class=\"num\">13.788<\/td><td class=\"num\">200<\/td><td class=\"num\">284<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">114<\/td><td>Dimethoate<\/td><td class=\"num\">13.857<\/td><td class=\"num\">200<\/td><td class=\"num\">87<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">115<\/td><td>Atrazine<\/td><td class=\"num\">14.064<\/td><td class=\"num\">200<\/td><td class=\"num\">200<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">116<\/td><td>4-Aminobiphenyl<\/td><td class=\"num\">14.17<\/td><td class=\"num\">200<\/td><td class=\"num\">169<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">117<\/td><td>Pentachlorophenol<\/td><td class=\"num\">14.17<\/td><td class=\"num\">200<\/td><td class=\"num\">266<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">118<\/td><td>Pentachloronitrobenzene (Quintozene)<\/td><td class=\"num\">14.213<\/td><td class=\"num\">200<\/td><td class=\"num\">237<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">119<\/td><td>Propyzamide<\/td><td class=\"num\">14.377<\/td><td class=\"num\">200<\/td><td class=\"num\">173<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">120<\/td><td>Phenanthrene-d10<\/td><td class=\"num\">14.477<\/td><td class=\"num\">200<\/td><td class=\"num\">188<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n\n      <tr><td class=\"num\">121<\/td><td>n-Octadecane (C18)<\/td><td class=\"num\">14.52<\/td><td class=\"num\">200<\/td><td class=\"num\">57<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">122<\/td><td>Phenanthrene<\/td><td class=\"num\">14.52<\/td><td class=\"num\">200<\/td><td class=\"num\">178<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">123<\/td><td>Dinoseb<\/td><td class=\"num\">14.616<\/td><td class=\"num\">200<\/td><td class=\"num\">211<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">124<\/td><td>Disulfoton<\/td><td class=\"num\">14.616<\/td><td class=\"num\">200<\/td><td class=\"num\">88<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">125<\/td><td>Anthracene<\/td><td class=\"num\">14.616<\/td><td class=\"num\">200<\/td><td class=\"num\">179<\/td><td class=\"num\">14<\/td><td class=\"center\">7<\/td><\/tr>\n      <tr><td class=\"num\">126<\/td><td>Carbazole<\/td><td class=\"num\">14.961<\/td><td class=\"num\">200<\/td><td class=\"num\">167<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n      <tr><td class=\"num\">127<\/td><td>Methyl parathion<\/td><td class=\"num\">15.296<\/td><td class=\"num\">200<\/td><td class=\"num\">109<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n      <tr><td class=\"num\">128<\/td><td>Di-n-butyl phthalate<\/td><td class=\"num\">15.779<\/td><td class=\"num\">200<\/td><td class=\"num\">149<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n      <tr><td class=\"num\">129<\/td><td>4-Nitroquinoline-N-oxide<\/td><td class=\"num\">16.026<\/td><td class=\"num\">200<\/td><td class=\"num\">190<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n      <tr><td class=\"num\">130<\/td><td>Parathion (ethyl parathion)<\/td><td class=\"num\">16.075<\/td><td class=\"num\">200<\/td><td class=\"num\">291<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n\n      <tr><td class=\"num\">131<\/td><td>Methapyrilene hydrochloride<\/td><td class=\"num\">16.273<\/td><td class=\"num\">200<\/td><td class=\"num\">58<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n      <tr><td class=\"num\">132<\/td><td>Isodrin<\/td><td class=\"num\">16.52<\/td><td class=\"num\">200<\/td><td class=\"num\">193<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n      <tr><td class=\"num\">133<\/td><td>Fluoranthene<\/td><td class=\"num\">16.806<\/td><td class=\"num\">200<\/td><td class=\"num\">202<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n      <tr><td class=\"num\">134<\/td><td>Benzidine<\/td><td class=\"num\">17.124<\/td><td class=\"num\">200<\/td><td class=\"num\">184<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n      <tr><td class=\"num\">135<\/td><td>Pyrene<\/td><td class=\"num\">17.223<\/td><td class=\"num\">200<\/td><td class=\"num\">203<\/td><td class=\"num\">30<\/td><td class=\"center\">8<\/td><\/tr>\n      \n      <tr><td class=\"num\">136<\/td><td>p-Terphenyl-d14<\/td><td class=\"num\">17.627<\/td><td class=\"num\">200<\/td><td class=\"num\">244<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">137<\/td><td>Aramite isomer 2<\/td><td class=\"num\">17.627<\/td><td class=\"num\">200<\/td><td class=\"num\">175<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">138<\/td><td>Aramite isomer 1<\/td><td class=\"num\">17.818<\/td><td class=\"num\">200<\/td><td class=\"num\">135<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">139<\/td><td>p-Dimethylaminoazobenzene<\/td><td class=\"num\">17.905<\/td><td class=\"num\">200<\/td><td class=\"num\">120<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">140<\/td><td>Chlorobenzilate<\/td><td class=\"num\">18.041<\/td><td class=\"num\">200<\/td><td class=\"num\">251<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n\n      <tr><td class=\"num\">141<\/td><td>Famphur<\/td><td class=\"num\">18.487<\/td><td class=\"num\">200<\/td><td class=\"num\">218<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">142<\/td><td>3,3&#8242;-Dimethylbenzidine (o-tolidine)<\/td><td class=\"num\">18.553<\/td><td class=\"num\">200<\/td><td class=\"num\">254<\/td><td class=\"num\">15<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">143<\/td><td>Kepone<\/td><td class=\"num\">18.553<\/td><td class=\"num\">200<\/td><td class=\"num\">272<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">144<\/td><td>Benzyl butyl phthalate<\/td><td class=\"num\">18.64<\/td><td class=\"num\">200<\/td><td class=\"num\">149<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">145<\/td><td>Bis(2-ethylhexyl)adipate<\/td><td class=\"num\">18.89<\/td><td class=\"num\">200<\/td><td class=\"num\">129<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">146<\/td><td>2-Acetylaminofluorene<\/td><td class=\"num\">19.015<\/td><td class=\"num\">200<\/td><td class=\"num\">181<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">147<\/td><td>4,4&#8242;-Methylene-bis(2-chloroaniline)<\/td><td class=\"num\">19.561<\/td><td class=\"num\">200<\/td><td class=\"num\">231<\/td><td class=\"num\">15<\/td><td class=\"center\">9<\/td><\/tr>\n      <tr><td class=\"num\">148<\/td><td>3,3&#8242;-Dichlorobenzidine<\/td><td class=\"num\">19.561<\/td><td class=\"num\">200<\/td><td class=\"num\">212<\/td><td class=\"num\">27<\/td><td class=\"center\">9<\/td><\/tr>\n\n      <tr><td class=\"num\">149<\/td><td>Benz[a]anthracene<\/td><td class=\"num\">19.561<\/td><td class=\"num\">200<\/td><td class=\"num\">228<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">150<\/td><td>Chrysene-d12<\/td><td class=\"num\">19.561<\/td><td class=\"num\">200<\/td><td class=\"num\">240<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">151<\/td><td>Chrysene<\/td><td class=\"num\">19.61<\/td><td class=\"num\">200<\/td><td class=\"num\">226<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">152<\/td><td>Bis(2-ethylhexyl)phthalate<\/td><td class=\"num\">19.824<\/td><td class=\"num\">200<\/td><td class=\"num\">167<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">153<\/td><td>6-Methylchrysene<\/td><td class=\"num\">20.473<\/td><td class=\"num\">200<\/td><td class=\"num\">242<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">154<\/td><td>Di-n-octyl phthalate<\/td><td class=\"num\">21.031<\/td><td class=\"num\">200<\/td><td class=\"num\">149<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">155<\/td><td>Benzo[b]fluoranthene<\/td><td class=\"num\">21.589<\/td><td class=\"num\">200<\/td><td class=\"num\">57<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">156<\/td><td>7,12-Dimethylbenz[a]anthracene<\/td><td class=\"num\">21.589<\/td><td class=\"num\">200<\/td><td class=\"num\">256<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">157<\/td><td>Benzo[k]fluoranthene<\/td><td class=\"num\">21.637<\/td><td class=\"num\">200<\/td><td class=\"num\">252<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">158<\/td><td>Benzo[a]pyrene<\/td><td class=\"num\">22.249<\/td><td class=\"num\">200<\/td><td class=\"num\">253<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">159<\/td><td>Perylene-d12<\/td><td class=\"num\">22.377<\/td><td class=\"num\">200<\/td><td class=\"num\">264<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">160<\/td><td>3-Methylcholanthrene<\/td><td class=\"num\">23.08<\/td><td class=\"num\">200<\/td><td class=\"num\">268<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n\n      <tr><td class=\"num\">161<\/td><td>Dibenz(a,h)acridine<\/td><td class=\"num\">24.357<\/td><td class=\"num\">200<\/td><td class=\"num\">279<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">162<\/td><td>Dibenz[a,j]acridine<\/td><td class=\"num\">24.48<\/td><td class=\"num\">200<\/td><td class=\"num\">280<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">163<\/td><td>Indeno[1,2,3-cd]pyrene<\/td><td class=\"num\">24.882<\/td><td class=\"num\">200<\/td><td class=\"num\">277<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">164<\/td><td>Dibenz[a,h]anthracene<\/td><td class=\"num\">24.968<\/td><td class=\"num\">200<\/td><td class=\"num\">278<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n      <tr><td class=\"num\">165<\/td><td>Benzo[g,h,i]perylene<\/td><td class=\"num\">25.537<\/td><td class=\"num\">200<\/td><td class=\"num\">276<\/td><td class=\"num\">15<\/td><td class=\"center\">10<\/td><\/tr>\n    <\/tbody>\n  <\/table>\n\n<\/div>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">\u307e\u3068\u3081\uff1a\u4f4e\u6fc3\u5ea6SVOC\u306eGC-MS\u5206\u6790\u3067\u611f\u5ea6\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u4e21\u7acb\u3059\u308b\u305f\u3081\u306b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4f4e\u6fc3\u5ea6\u306e\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u3092GC-MS\u3067\u5206\u6790\u3059\u308b\u969b\u306b\u306f\u3001\u611f\u5ea6\u4f4e\u4e0b\u3084\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u52a3\u5316\u304c\u5927\u304d\u306a\u8ab2\u984c\u3068\u306a\u308a\u307e\u3059\u3002\u672c\u8a18\u4e8b\u3067\u793a\u3057\u305f\u7d50\u679c\u304b\u3089\u3001\u30ab\u30e9\u30e0\u306e\u4e0d\u6d3b\u6027\u5ea6\u3092\u542b\u3080\u30b7\u30b9\u30c6\u30e0\u5168\u4f53\u306e\u6700\u9069\u5316\u306b\u3088\u308a\u3001scan\u304a\u3088\u3073SIM\u306e\u3044\u305a\u308c\u306b\u304a\u3044\u3066\u3082\u9ad8\u54c1\u8cea\u306a\u5206\u6790\u304c\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size wp-block-paragraph\" style=\"margin-top:4px;margin-bottom:4px\"><strong>References \u53c2\u7167\u6587\u732e<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>E. Pack, J. Hoisington, C. English, R. Dhandapani, and C. Myers, <a href=\"https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan4920-ja\/comprehensive-trace-level-gc-ms-ms-semivolatiles-method-ja\">\u5fae\u91cf\u30ec\u30d9\u30eb\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306eGC-MS\/MS\u4e00\u6589\u5206\u6790\u6cd5\uff1a\u30c7\u30fc\u30bf\u54c1\u8cea\u306e\u7dad\u6301\u3068\u691c\u51fa\u4e0b\u9650\u306e\u6539\u5584<\/a>, Application note, EVAN4920-JA, Restek Corporation, 2025.<\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnbr4923-ja\/rmx-gc-columns-unleash-your-performance-ja\">RMX GC\u30ab\u30e9\u30e0\u30ab\u30bf\u30ed\u30b0<\/a>, GNBR4923A-JA, Restek Corporation, 2026.<\/li>\n<\/ol>\n\n\n\n<div style=\"height:39px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image69290_91bd6b-67.kb-image-is-ratio-size, .kb-image69290_91bd6b-67 .kb-image-is-ratio-size{max-width:800px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image69290_91bd6b-67.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image69290_91bd6b-67 .kb-image-is-ratio-size{align-self:unset;}.kb-image69290_91bd6b-67 figure{max-width:800px;}.kb-image69290_91bd6b-67 .image-is-svg, .kb-image69290_91bd6b-67 .image-is-svg img{width:100%;}.kb-image69290_91bd6b-67:not(.kb-image-is-ratio-size) .kb-img, .kb-image69290_91bd6b-67.kb-image-is-ratio-size{padding-right:50px;padding-left:50px;}.kb-image69290_91bd6b-67 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image69290_91bd6b-67\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/discover.restek.com\/ja\/rmx\/\" class=\"kb-advanced-image-link\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1014\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-1024x1014.png\" alt=\"GC\u30ab\u30e9\u30e0, \u4e0d\u6d3b\u6027, \u4f4e\u5438\u7740\" class=\"kb-img wp-image-81470\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-1024x1014.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-300x297.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-768x760.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-1536x1521.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-2048x2027.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>\u30ab\u30e9\u30e0\u5185\u306e\u6d3b\u6027\u70b9\u3092\u6291\u3048\u305f\u3001\u9ad8\u611f\u5ea6\u30fb\u9577\u5bff\u547d\u306a\u30ab\u30e9\u30e0<\/figcaption><\/figure><\/div>\n\n\n<style>.kb-image69290_c2dc75-80.kb-image-is-ratio-size, .kb-image69290_c2dc75-80 .kb-image-is-ratio-size{max-width:800px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image69290_c2dc75-80.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image69290_c2dc75-80 .kb-image-is-ratio-size{align-self:unset;}.kb-image69290_c2dc75-80 figure{max-width:800px;}.kb-image69290_c2dc75-80 .image-is-svg, .kb-image69290_c2dc75-80 .image-is-svg img{width:100%;}.kb-image69290_c2dc75-80:not(.kb-image-is-ratio-size) .kb-img, .kb-image69290_c2dc75-80.kb-image-is-ratio-size{padding-right:100px;padding-left:100px;}.kb-image69290_c2dc75-80 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image69290_c2dc75-80\"><figure class=\"aligncenter size-full\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-sales-JP\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"424\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-scaled.jpg\" alt=\"\u304a\u554f\u3044\u5408\u308f\u305b\uff5cRestek\" class=\"kb-img wp-image-81960\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-scaled.jpg 2560w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-300x50.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-1024x169.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-768x127.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-1536x254.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-2048x339.jpg 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:39px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u95a2\u9023\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">                                \u30ab\u30bf\u30ed\u30b0No. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">                                \u30ab\u30bf\u30ed\u30b0No. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">                                \u30ab\u30bf\u30ed\u30b0No. 31907                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">SVOC MegaMix 150 Kit, 1 mL\/ampul; 6 ampuls\/kit<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31907\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31615\">                                \u30ab\u30bf\u30ed\u30b0No. 31615                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">GC-MS Tuning Mix, 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31615\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">                                \u30ab\u30bf\u30ed\u30b0No. 31025                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Acid Surrogate Mix (4\/89 SOW), 2000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">                                \u30ab\u30bf\u30ed\u30b0No. 31024                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Base Neutral Surrogate Mix (4\/89 SOW), 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">                                \u30ab\u30bf\u30ed\u30b0No. 31886                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Revised SV Internal Standard Mix, 4000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<script>\ndocument.addEventListener(\"DOMContentLoaded\", function() {\n  try {\n    const target = document.querySelector('.chromato-narrow');\n    if (!target) return;\n\n    const resizeInner = () => {\n      const inner = target.querySelector('div');\n      if (inner) {\n        inner.style.width = '100%';\n        inner.style.maxWidth = '600px';\n        inner.style.margin = '0 auto';\n      }\n    };\n\n    resizeInner();\n\n    const observer = new MutationObserver(() => resizeInner());\n    observer.observe(target, { childList: true, subtree: true });\n  } catch(e) {\n    console.log('Chromatogram resize skipped:', e);\n  }\n});\n<\/script>\n","protected":false},"excerpt":{"rendered":"<p>\u4f4e\u6fc3\u5ea6SVOC\u5206\u6790\u306b\u304a\u3051\u308bGC-MS\u306e\u611f\u5ea6\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u8ab2\u984c Key Highlights SVOC\u306eGC-MS\u5206\u6790\u3067\u691c\u51fa\u9650\u754c\u306e\u6539\u5584\u304c\u6c42\u3081\u3089\u308c\u308b\u80cc\u666f \u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u5206\u6790\u3092\u5b9f\u65bd\u3059\u308b\u30e9\u30dc\u3067\u306f\u3001\u9867\u5ba2\u8981\u6c42\u3084\u6eb6\u5a92\u524a\u6e1b\uff08\u898f\u5236\u5bfe\u5fdc\u30fb\u30b3\u30b9\u30c8\u524a\u6e1b\uff09\u306e\u305f\u3081\u3001\u691c\u51fa\u9650\u754c\u306e\u5f15\u304d\u4e0b\u3052\u304c\u5e38\u306b\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002 MS \u30d9\u30fc\u30b9\u306e\u30e1\u30bd\u30c3\u30c9\uff08\u4f8b\uff1aEPA 8270\uff09\u306f\u4e00\u822c\u7684\u306a\u30a2\u30d7\u30ed\u30fc\u30c1\u3067\u3042\u308a\u3001MS \u3092\u6d3b\u7528\u3059\u308b\u3053\u3068\u3067\u3088\u308a\u4f4e\u3044\u691c\u51fa\u9650\u754c\u3092\u5b9f\u73fe\u3067\u304d\u307e\u3059\u3002 EPA Method 8270\u306b\u4ee3\u8868\u3055\u308c\u308bMS\u3092\u7528\u3044\u305fSVOC\u306e\u5206\u6790\u624b\u6cd5\u306f\u5e83\u304f\u6d3b\u7528\u3055\u308c\u3066\u304a\u308a\u3001\u30e9\u30dc\u306f\u76ee\u7684\u306b\u5fdc\u3058\u3066\u30d9\u30b9\u30c8\u306a\u691c\u51fa\u9650\u754c\u3092\u9054\u6210\u3067\u304d\u308b\u88c5\u7f6e\u3092\u67d4\u8edf\u306b\u9078\u629e\u3067\u304d\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001GC-MS\/MS\u306e\u3088\u3046\u306a\u9ad8\u611f\u5ea6\u306a\u88c5\u7f6e\u3092\u63a1\u7528\u3059\u308b\u5834\u5408\u3082\u3042\u308b\u4e00\u65b9\u3067\u3001GC-MS\u3092\u7528\u3044\u3066SIM\u306b\u3088\u308b\u611f\u5ea6\u5411\u4e0a\u3092\u56f3\u308b\u904b\u7528\u3084\u3001\u3088\u308a\u6c4e\u7528\u7684\u306ascan\u30e2\u30fc\u30c9\u306b\u3088\u308b\u5206\u6790\u3092\u9078\u629e\u3059\u308b\u5834\u5408\u3082\u3042\u308a\u307e\u3059\u3002 SVOC\u5206\u6790\u306b\u304a\u3051\u308bGC-MS\u306eScan\u6cd5\u3068SIM\u6cd5\u306e\u4f7f\u3044\u5206\u3051 SIM\u3068scan\u306f\u3069\u3061\u3089\u3082GC-MS\u3067\u5b9f\u65bd\u53ef\u80fd\u3067\u3059\u304c\u3001scan\u304c\u5e45\u5e83\u3044\u8cea\u91cf\u7bc4\u56f2\u306e\u4fe1\u53f7\u3092\u307e\u3068\u3081\u3066\u53d6\u5f97\u3059\u308b\u30b7\u30f3\u30d7\u30eb\u3067\u6c4e\u7528\u7684\u306a\u624b\u6cd5\u3067\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001SIM\u306f\u7279\u5b9a\u30a4\u30aa\u30f3\u3092\u7279\u5b9a\u306e\u4fdd\u6301\u6642\u9593\u306b\u7d5e\u3063\u3066\u6e2c\u5b9a\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u308b\u305f\u3081\u3001\u3088\u308a\u9ad8\u3044\u611f\u5ea6\u304c\u5f97\u3089\u308c\u307e\u3059\u3002SIM\u306f\u30e1\u30bd\u30c3\u30c9\u306e\u8a2d\u5b9a\u3084\u7dad\u6301\u304c\u7169\u96d1\u306b\u306a\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u691c\u51fa\u9650\u754c\u306e\u5f15\u304d\u4e0b\u3052\u3092\u691c\u8a0e\u3059\u308b\u5834\u5408\u3001\u65b0\u305f\u306a\u88c5\u7f6e\u6295\u8cc7\u3092\u884c\u308f\u305a\u306b\u611f\u5ea6\u3092\u9ad8\u3081\u308b\u9078\u629e\u80a2\u3068\u3057\u3066\u3001GC-MS\u306eSIM\u904b\u7528\u304c\u6709\u529b\u5019\u88dc\u306b\u306a\u308a\u307e\u3059\u3002 \u4f4e\u6fc3\u5ea6SVOC\u5206\u6790\u3092\u60f3\u5b9a\u3057\u305fGC-MS\u6e2c\u5b9a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc \u672c\u7814\u7a76\u3067\u306f\u3001\u30b7\u30f3\u30d7\u30eb\u3067\u5805\u7262\u306ascan\u3068\u3001GC-MS\/MS\u306b\u4ee3\u308f\u308a\u5f97\u308b\u9ad8\u611f\u5ea6\u306aSIM\u3068\u3044\u3046\u4e8c\u3064\u306e\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u76ee\u7684\u306b\u5fdc\u3058\u3066\u9078\u629e\u3067\u304d\u308b\u3088\u3046\u3001scan\u3068SIM\u306e\u4e21\u30e2\u30fc\u30c9\u306b\u304a\u3051\u308bGC-MS\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306e\u6761\u4ef6\u3092\u78ba\u7acb\u3057\u307e\u3057\u305f\uff08Figure 1 \uff06 Figure 2\uff09\u3002 RMX-5Sil MS \u30ab\u30e9\u30e0\u306b\u3088\u308bSVOC\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u8a55\u4fa1 \u3044\u305a\u308c\u306e\u30e1\u30bd\u30c3\u30c9\u3082RMX-5Sil MS\u30ab\u30e9\u30e0\u3092\u63a1\u7528\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u30ab\u30e9\u30e0\u306f\u6a19\u6e96\u7684\u306a5sil\u306e\u9078\u629e\u6027\u3092\u5099\u3048\u306a\u304c\u3089\u3082\u3001\u6b21\u4e16\u4ee3\u306eTriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u3001\u6975\u3081\u3066\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u5b9f\u73fe\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059[1,2]\u3002Figure 2\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u30d9\u30f3\u30b8\u30b8\u30f3\u3001\u30da\u30f3\u30bf\u30af\u30ed\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u30012,4-\u30b8\u30cb\u30c8\u30ed\u30d5\u30a7\u30ce\u30fc\u30eb\u3068\u3044\u3063\u305f\u4e3b\u8981\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u3001\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u306f\u4e00\u8cab\u3057\u3066\u54c1\u8cea\u76ee\u6a19\uff08\u22642\uff09\u3092\u6e80\u305f\u3057\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u5206\u96e2\u304c\u96e3\u3057\u3044PAH \u985e\u306b\u3064\u3044\u3066\u306f\u3001EPA 8270\u306e\u30b7\u30b9\u30c6\u30e0\u9069\u5408\u6027\u3067\u6c42\u3081\u3089\u308c\u308bvalley% \u57fa\u6e96\uff08&gt;50%\uff09\u306b\u5bfe\u3057\u3001benzo[b]fluoranthene\u3068 benzo[k]fluoranthene\u306e\u30d4\u30fc\u30af\u9593 valley% \u306f94%\u3001indeno[1,2,3-cd]pyrene \u3068 dibenz[a,h]anthracene\u306evalley%\u306f 95%\u3068\u3001\u6975\u3081\u3066\u826f\u597d\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002 pg\u30ec\u30d9\u30eb\u306b\u304a\u3051\u308bSVOC\u306e\u611f\u5ea6\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u8a55\u4fa1\u7d50\u679c \u307e\u305f\u3001\u672c\u7a3f\u3067\u793a\u3057\u305f\u6761\u4ef6\u4e0b\u3067 RMX-5Sil MS \u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305f\u3068\u3053\u308d\u3001scan \u30e2\u30fc\u30c9\u3067\u306f 1 ng on-column\u3001SIM \u30e2\u30fc\u30c9\u3067\u306f 200 pg on-column\u3068\u3044\u3046\u6975\u3081\u3066\u4f4e\u3044\u30aa\u30f3\u30ab\u30e9\u30e0\u91cf\u306b\u304a\u3044\u3066\u3082\u3001\u5e45\u5e83\u3044\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u5341\u5206\u306a\u5206\u96e2\u6027\u80fd\u304c\u7dad\u6301\u3055\u308c\u3001MS\u306e\u691c\u51fa\u9650\u754c\u8fd1\u508d\u306b\u304a\u3044\u3066\u3082\u611f\u5ea6\u304a\u3088\u3073\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u306e\u4e21\u7acb\u304c\u53ef\u80fd\u3067\u3042\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002 GC-MS\u306b\u3088\u308b\u4f4e\u6fc3\u5ea6SVOC165\u6210\u5206\u5206\u6790\u306e\u5b9f\u6e2c\u30c7\u30fc\u30bf GC-MS\u306b\u3088\u308b\u4f4e\u6fc3\u5ea6SVOC 165\u6210\u5206\u5206\u6790\u306b\u304a\u3051\u308bRMX-5Sil MS\u30ab\u30e9\u30e0\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u6027\u80fd\u8a55\u4fa1\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u4ee5\u4e0b\u306b\u793a\u3057\u307e\u3059\u3002 Figure 1. scan&#8230;<\/p>\n","protected":false},"author":18,"featured_media":61151,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"default","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[2745],"industries-application":[2751,2289,2271,2287],"post-badge":[2752],"resource-type":[],"product-library":[],"resource-technique":[2340,2345],"ppma_author":[438,454,2657,452],"class_list":["post-69290","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-rmx-resources","industries-application-semivolatiles","industries-application-soil-sediment-biota-testing-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja","post-badge-new","resource-technique-gas-chromatography-gc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2745,"label":"RMX \u8d44\u6e90\u5e93"}],"industries-application":[{"value":2751,"label":"Semivolatiles"},{"value":2289,"label":"\u571f\u58cc\uff5c\u5e95\u8cea\uff5c\u751f\u7269\u8a66\u6599 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}],"post-badge":[{"value":2752,"label":"New"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA4921-1024x568.jpg",1024,568,true],"author_info":{"display_name":"Jessi Collier","author_link":"https:\/\/discover.restek.com\/ja\/author\/jessi-collier\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2745,"name":"RMX \u8d44\u6e90\u5e93","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2745,"taxonomy":"post_tag","description":"\u7acb\u5373\u63a2\u7d22 RMX \u8d44\u6e90\u5e93","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":438,"user_id":18,"is_guest":0,"slug":"jessi-collier","display_name":"Jessi Collier","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-collier-jessi.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-collier-jessi.jpg"},"author_category":"1","first_name":"Jessi","last_name":"Collier","user_url":"https:\/\/www.linkedin.com\/in\/jessi-collier\/","job_title":"Advanced Scientist, GC Applied","description":"Jessi is an advanced scientist in the GC applications group where her work focuses on environmental and food contaminants. Prior to joining Restek in 2023, she worked for the Mississippi State Chemical Lab as a pesticide residue analyst, primarily testing regulatory samples, agricultural samples, environmental samples, foods, and other consumer products via GC-MS, GC-MS\/MS, GC-FID, and GC-ECD. Jessi holds a BS in chemistry and a BA in Mandarin Chinese from Mississippi State University."},{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":2657,"user_id":70,"is_guest":0,"slug":"ramkumar-dhandapani-phd","display_name":"Ramkumar Dhandapani, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg"},"author_category":"1","first_name":"Ramkumar","last_name":"Dhandapani","user_url":"https:\/\/www.linkedin.com\/in\/dr-ramkumar-dhandapani-b9012424\/?skipRedirect=true&enhance=null","job_title":"Director of Product Management","description":"Dr. Ramkumar Dhandapani\u00a0is a seasoned analytical chemist with over\u00a023 years of experience\u00a0in the chromatography industry and a Ph.D. in analytical chemistry. During his career, he has specialized in method development, validation, and the troubleshooting of chromatography methods. He has developed numerous regulatory-compliant methods across diverse sectors, including\u00a0environmental analysis, food quality and safety, pharmaceutical, fuels, and chemical industries. Currently, Dr. Dhandapani is the Director of Product Management at Restek, he is keen on innovation in chromatography and scaling breakthrough innovations\u00a0to market as commercial products."},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/69290","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/18"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=69290"}],"version-history":[{"count":113,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/69290\/revisions"}],"predecessor-version":[{"id":86827,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/69290\/revisions\/86827"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/61151"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=69290"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=69290"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=69290"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=69290"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=69290"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=69290"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=69290"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=69290"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=69290"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}