{"id":70855,"date":"2018-05-16T04:00:00","date_gmt":"2018-05-16T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=70855"},"modified":"2026-01-24T04:08:35","modified_gmt":"2026-01-24T04:08:35","slug":"choosing-the-right-quechers-extraction-salt-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav4890-ja\/choosing-the-right-quechers-extraction-salt-japan","title":{"rendered":"\u9069\u5207\u306aQuEChERS\u62bd\u51fa\u5869\u306e\u9078\u3073\u65b9"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-16-9 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Choosing the Right QuEChERS Extraction Salt\" width=\"720\" height=\"405\" src=\"https:\/\/www.youtube.com\/embed\/_3tLlxnjMKk?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"373\" data-id=\"29853\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png\" alt=\"\" class=\"wp-image-29853\" style=\"width:165px;height:auto\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png 512w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1-300x219.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"528\" data-id=\"29859\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png\" alt=\"\" class=\"wp-image-29859\" style=\"width:111px;height:auto\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png 447w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12-254x300.png 254w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure>\n<\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6982\u8981<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">QuEChERS(\u8fc5\u901f(Quick)\u3001\u7c21\u5358(Easy)\u3001\u5b89\u4fa1(Cheap)\u3001\u52b9\u679c\u7684(Effective)\u3001\u9811\u5065(Rugged)\u3001\u5b89\u5168(Safe))\u524d\u51e6\u7406\u6cd5\u306f\u6025\u901f\u306b\u666e\u53ca\u3057\u307e\u3057\u305f\u3002\u3082\u3068\u3082\u3068\u306f\u3001\u98df\u54c1\u4e2d\u306e\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3057\u305f\u304c\u3001\u3053\u306e\u624b\u6cd5\u306f\u305d\u306e\u4ed6\u306e\u591a\u304f\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u3082\u9069\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u9069\u5207\u306a\u62bd\u51fa\u5869\u306e\u9078\u629e\u306f\u3069\u3046\u3059\u308b\u304b\u306a\u3069\u3001\u96e3\u3057\u3044\u554f\u984c\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u3001\u6700\u9069\u306a\u9078\u629e\u3092\u3059\u308b\u305f\u3081\u306e\u60c5\u5831\u3092\u5171\u6709\u3057\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u305d\u306e\u4ed6\u306e\u30ea\u30bd\u30fc\u30b9<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/articles\/quechers-made-even-easier\" target=\"_blank\" rel=\"noopener\"><\/a><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/ffss1183-ja\/japanese-quechers-made-even-easier\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/FFSS1183-JA\/japanese-quechers-made-even-easier\" rel=\"noreferrer noopener\">QuEChERS\u3092\u3055\u3089\u306b\u306b\u7c21\u5358\u306b: \u5305\u62ec\u7684\u306a\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3067\u30b7\u30f3\u30d7\u30eb\u306a\u524d\u51e6\u7406\u3068\u5206\u6790\u3092<\/a><\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Restek\u63a8\u5968\u30c4\u30fc\u30eb\u3068\u90e8\u54c1<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1344\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/ja\/c\/1344\" target=\"_blank\" rel=\"noopener\">Q-sep QuEChERS Extraction Salts<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/www.restek.com\/global\/ja\/c\/1343\" data-type=\"link\" data-id=\"https:\/\/www.restek.com\/global\/ja\/c\/1343\" target=\"_blank\" rel=\"noopener\">Q-Sep QuEChERS dSPE Tubes<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3093\u306b\u3061\u306f\u3001Restek Tip\u3078\u3088\u3046\u3053\u305d\u3002\u3053\u3053\u3067\u306f\u3001QuEChERS\u62bd\u51fa\u5869\u306e\u9078\u3073\u65b9\u306b\u3064\u3044\u3066\u304a\u8a71\u3057\u3057\u307e\u3059\u3002\u3053\u306e\u7d20\u6674\u3089\u3057\u3044QuEChERS\u6cd5\u3092\u8a66\u3059\u3053\u3068\u306b\u306a\u3063\u305f\u5834\u5408\u3001\u4f55\u304c\u5fc5\u8981\u304b\u3092\u63a2\u3059\u3053\u3068\u304b\u3089\u59cb\u3081\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u305d\u3057\u3066\u307e\u305a\u6700\u521d\u306b\u77e5\u308b\u306e\u306f\u3001\u62bd\u51fa\u5869\u3092\u4f7f\u3063\u305f\u30e1\u30bd\u30c3\u30c9\u304c3\u7a2e\u985e\u3042\u308b\u3053\u3068\u3067\u3059\u3002\u307e\u305a\u306f\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u3001\u305d\u3057\u3066\u3053\u306e\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u6539\u5b9a\u7248\u3067\u3042\u308b2\u3064\u306e\u30e1\u30bd\u30c3\u30c9\u3001\u3064\u307e\u308a\u3001EN\u6cd5\u3068AOAC\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e2\u3064\u306f\u3001\u30e1\u30bd\u30c3\u30c9\u3092\u516c\u958b\u3057\u305f\u56e3\u4f53\u306b\u3061\u306a\u3093\u3067\u540d\u4ed8\u3051\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3067\u306f\u3001\u3069\u308c\u3092\u9078\u3093\u3060\u3089\u3088\u3044\u306e\u3067\u3057\u3087\u3046\u304b\uff1f2\u3064\u306e\u9078\u629e\u80a2\u306e\u3069\u3061\u3089\u304b\u3001\u3059\u306a\u308f\u3061\u6539\u5b9a\u7248\u3068\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u7406\u89e3\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u3053\u306e2\u3064\u306e\u9055\u3044\u3092\u7406\u89e3\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u300c\u975e\u7de9\u885d\u6cd5\u300d\u3068\u3082\u547c\u3070\u308c\u3066\u3044\u307e\u3059\u3002\u3069\u3046\u3044\u3046\u610f\u5473\u304b\u3092\u8aac\u660e\u3057\u307e\u3057\u3087\u3046\u3002\u300c\u975e\u7de9\u885d\u300d\u3067\u3042\u308b\u3068\u3044\u3046\u3053\u3068\u306f\u3001\u6700\u7d42\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u306epH\u304c\u307b\u3068\u3093\u3069\u5b8c\u5168\u306b\u8a66\u6599\uff08\u5bfe\u8c61\u7269\uff09\u305d\u306e\u3082\u306e\u306b\u3088\u3063\u3066\u6c7a\u307e\u308b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u3064\u307e\u308a\u300c\u306a\u308b\u3088\u3046\u306b\u3057\u304b\u306a\u3089\u306a\u3044\u300d\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u308c\u3068\u53cd\u5bfe\u306b\u3001\uff12\u3064\u306e\u6539\u5b9a\u7248\u306e\u30e1\u30bd\u30c3\u30c9\u3001EN\u6cd5\u3068AOAC\u6cd5\u306f\u3069\u3061\u3089\u3082\u300c\u7de9\u885d\u6cd5\u300d\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u307b\u3068\u3093\u3069\u306e\u8fb2\u85ac\u306b\u5bfe\u3057\u3066\u6975\u3081\u3066\u5b89\u5b9a\u306apH\u7bc4\u56f2\u306b\u3082\u3063\u3066\u3044\u304f\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u3066\u5869\u304c\u52a0\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u3057\u3066\u305d\u308c\u306f\u3001AOAC\u6cd5\u3067\u306fpH5\u3092\u5c11\u3057\u4e0b\u56de\u308b\u304f\u3089\u3044\u3001EN\u6cd5\u3067\u306fpH5-5.5\u7a0b\u5ea6\u3067\u3059\u3002&nbsp;<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3067\u306f\u3001\u3069\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u9078\u3076\u3079\u304d\u3067\u3057\u3087\u3046\u304b\uff1f\u6700\u7d42\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u306epH\u306b\u95a2\u308f\u3089\u305a\u3001\u5b89\u5b9a\u3057\u3066\u3044\u308b\u8fb2\u85ac\u3092\u6271\u3046\u5834\u5408\u306b\u306f\u3001\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u304c\u6700\u9069\u3067\u3057\u3087\u3046\u3002\u307b\u3068\u3093\u3069\u306e\u8fb2\u85ac\u3068\u307b\u3068\u3093\u3069\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304c\u5f53\u3066\u306f\u307e\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u5b9f\u969b\u306e\u30b5\u30f3\u30d7\u30eb\u81ea\u4f53\u306epH\u304c\u539f\u56e0\u3067\u5316\u5408\u7269\u306e\u5b89\u5b9a\u6027\u304c\u61f8\u5ff5\u3055\u308c\u308b\u5834\u5408\u306b\u306f\u3001\u7de9\u885d\u6cd5\u306e\u3044\u305a\u308c\u304b\u304c\u9069\u3057\u305f\u3082\u306e\u306b\u306a\u308b\u3067\u3057\u3087\u3046\u3057\u3001\u3069\u3061\u3089\u3092\u4f7f\u3063\u3066\u3082\u5206\u6790\u76ee\u7684\u306b\u9069\u3057\u305f\u9078\u629e\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3068\u3044\u3046\u4e8b\u3067\u3001\u3053\u306e\u6b21\u306eQuEChERS\u62bd\u51fa\u304c\u3046\u307e\u304f\u3044\u304f\u3053\u3068\u3092\u7948\u3063\u3066\u3044\u307e\u3059\u3002Restek Tip\u3092\u3054\u89a7\u3044\u305f\u3060\u304d\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002 \u6982\u8981 QuEChERS(\u8fc5\u901f(Quick)\u3001\u7c21\u5358(Easy)\u3001\u5b89\u4fa1(Cheap)\u3001\u52b9\u679c\u7684(Effective)\u3001\u9811\u5065(Rugged)\u3001\u5b89\u5168(Safe))\u524d\u51e6\u7406\u6cd5\u306f\u6025\u901f\u306b\u666e\u53ca\u3057\u307e\u3057\u305f\u3002\u3082\u3068\u3082\u3068\u306f\u3001\u98df\u54c1\u4e2d\u306e\u6b8b\u7559\u8fb2\u85ac\u5206\u6790\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3057\u305f\u304c\u3001\u3053\u306e\u624b\u6cd5\u306f\u305d\u306e\u4ed6\u306e\u591a\u304f\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u306b\u3082\u9069\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u9069\u5207\u306a\u62bd\u51fa\u5869\u306e\u9078\u629e\u306f\u3069\u3046\u3059\u308b\u304b\u306a\u3069\u3001\u96e3\u3057\u3044\u554f\u984c\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u3053\u3067\u306f\u3001\u6700\u9069\u306a\u9078\u629e\u3092\u3059\u308b\u305f\u3081\u306e\u60c5\u5831\u3092\u5171\u6709\u3057\u307e\u3059\u3002&nbsp; \u305d\u306e\u4ed6\u306e\u30ea\u30bd\u30fc\u30b9 Restek\u63a8\u5968\u30c4\u30fc\u30eb\u3068\u90e8\u54c1 \u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8 \u3053\u3093\u306b\u3061\u306f\u3001Restek Tip\u3078\u3088\u3046\u3053\u305d\u3002\u3053\u3053\u3067\u306f\u3001QuEChERS\u62bd\u51fa\u5869\u306e\u9078\u3073\u65b9\u306b\u3064\u3044\u3066\u304a\u8a71\u3057\u3057\u307e\u3059\u3002\u3053\u306e\u7d20\u6674\u3089\u3057\u3044QuEChERS\u6cd5\u3092\u8a66\u3059\u3053\u3068\u306b\u306a\u3063\u305f\u5834\u5408\u3001\u4f55\u304c\u5fc5\u8981\u304b\u3092\u63a2\u3059\u3053\u3068\u304b\u3089\u59cb\u3081\u308b\u3068\u601d\u3044\u307e\u3059\u3002\u305d\u3057\u3066\u307e\u305a\u6700\u521d\u306b\u77e5\u308b\u306e\u306f\u3001\u62bd\u51fa\u5869\u3092\u4f7f\u3063\u305f\u30e1\u30bd\u30c3\u30c9\u304c3\u7a2e\u985e\u3042\u308b\u3053\u3068\u3067\u3059\u3002\u307e\u305a\u306f\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u3001\u305d\u3057\u3066\u3053\u306e\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u6539\u5b9a\u7248\u3067\u3042\u308b2\u3064\u306e\u30e1\u30bd\u30c3\u30c9\u3001\u3064\u307e\u308a\u3001EN\u6cd5\u3068AOAC\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e2\u3064\u306f\u3001\u30e1\u30bd\u30c3\u30c9\u3092\u516c\u958b\u3057\u305f\u56e3\u4f53\u306b\u3061\u306a\u3093\u3067\u540d\u4ed8\u3051\u3089\u308c\u307e\u3057\u305f\u3002 \u3067\u306f\u3001\u3069\u308c\u3092\u9078\u3093\u3060\u3089\u3088\u3044\u306e\u3067\u3057\u3087\u3046\u304b\uff1f2\u3064\u306e\u9078\u629e\u80a2\u306e\u3069\u3061\u3089\u304b\u3001\u3059\u306a\u308f\u3061\u6539\u5b9a\u7248\u3068\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u7406\u89e3\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u3053\u306e2\u3064\u306e\u9055\u3044\u3092\u7406\u89e3\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u300c\u975e\u7de9\u885d\u6cd5\u300d\u3068\u3082\u547c\u3070\u308c\u3066\u3044\u307e\u3059\u3002\u3069\u3046\u3044\u3046\u610f\u5473\u304b\u3092\u8aac\u660e\u3057\u307e\u3057\u3087\u3046\u3002\u300c\u975e\u7de9\u885d\u300d\u3067\u3042\u308b\u3068\u3044\u3046\u3053\u3068\u306f\u3001\u6700\u7d42\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u306epH\u304c\u307b\u3068\u3093\u3069\u5b8c\u5168\u306b\u8a66\u6599\uff08\u5bfe\u8c61\u7269\uff09\u305d\u306e\u3082\u306e\u306b\u3088\u3063\u3066\u6c7a\u307e\u308b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u3064\u307e\u308a\u300c\u306a\u308b\u3088\u3046\u306b\u3057\u304b\u306a\u3089\u306a\u3044\u300d\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002 \u3053\u308c\u3068\u53cd\u5bfe\u306b\u3001\uff12\u3064\u306e\u6539\u5b9a\u7248\u306e\u30e1\u30bd\u30c3\u30c9\u3001EN\u6cd5\u3068AOAC\u6cd5\u306f\u3069\u3061\u3089\u3082\u300c\u7de9\u885d\u6cd5\u300d\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u307b\u3068\u3093\u3069\u306e\u8fb2\u85ac\u306b\u5bfe\u3057\u3066\u6975\u3081\u3066\u5b89\u5b9a\u306apH\u7bc4\u56f2\u306b\u3082\u3063\u3066\u3044\u304f\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u3066\u5869\u304c\u52a0\u3048\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u3057\u3066\u305d\u308c\u306f\u3001AOAC\u6cd5\u3067\u306fpH5\u3092\u5c11\u3057\u4e0b\u56de\u308b\u304f\u3089\u3044\u3001EN\u6cd5\u3067\u306fpH5-5.5\u7a0b\u5ea6\u3067\u3059\u3002&nbsp; \u3067\u306f\u3001\u3069\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u9078\u3076\u3079\u304d\u3067\u3057\u3087\u3046\u304b\uff1f\u6700\u7d42\u7684\u306a\u30b5\u30f3\u30d7\u30eb\u306epH\u306b\u95a2\u308f\u3089\u305a\u3001\u5b89\u5b9a\u3057\u3066\u3044\u308b\u8fb2\u85ac\u3092\u6271\u3046\u5834\u5408\u306b\u306f\u3001\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u30e1\u30bd\u30c3\u30c9\u304c\u6700\u9069\u3067\u3057\u3087\u3046\u3002\u307b\u3068\u3093\u3069\u306e\u8fb2\u85ac\u3068\u307b\u3068\u3093\u3069\u306e\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304c\u5f53\u3066\u306f\u307e\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u5b9f\u969b\u306e\u30b5\u30f3\u30d7\u30eb\u81ea\u4f53\u306epH\u304c\u539f\u56e0\u3067\u5316\u5408\u7269\u306e\u5b89\u5b9a\u6027\u304c\u61f8\u5ff5\u3055\u308c\u308b\u5834\u5408\u306b\u306f\u3001\u7de9\u885d\u6cd5\u306e\u3044\u305a\u308c\u304b\u304c\u9069\u3057\u305f\u3082\u306e\u306b\u306a\u308b\u3067\u3057\u3087\u3046\u3057\u3001\u3069\u3061\u3089\u3092\u4f7f\u3063\u3066\u3082\u5206\u6790\u76ee\u7684\u306b\u9069\u3057\u305f\u9078\u629e\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002 \u3068\u3044\u3046\u4e8b\u3067\u3001\u3053\u306e\u6b21\u306eQuEChERS\u62bd\u51fa\u304c\u3046\u307e\u304f\u3044\u304f\u3053\u3068\u3092\u7948\u3063\u3066\u3044\u307e\u3059\u3002Restek Tip\u3092\u3054\u89a7\u3044\u305f\u3060\u304d\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002<\/p>\n","protected":false},"author":11,"featured_media":41453,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[],"industries-application":[2275,2274],"post-badge":[],"resource-type":[],"product-library":[2580,2555],"resource-technique":[2370],"ppma_author":[414],"class_list":["post-70855","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","industries-application-food-safety-ja","industries-application-food-beverage-ja","product-library-quechers-ja","product-library-sample-preparation-products-ja","resource-technique-quechers-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"industries-application":[{"value":2275,"label":"\u98df\u306e\u5b89\u5168"},{"value":2274,"label":"\u98df\u54c1\uff5c\u98f2\u6599"}],"product-library":[{"value":2580,"label":"QuEChERS"},{"value":2555,"label":"\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406"}],"resource-technique":[{"value":2370,"label":"QuEChERS"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV4890-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":774,"category_count":139,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/70855","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=70855"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/70855\/revisions"}],"predecessor-version":[{"id":84531,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/70855\/revisions\/84531"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41453"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=70855"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=70855"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=70855"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=70855"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=70855"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=70855"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=70855"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=70855"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=70855"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}