{"id":71178,"date":"2018-06-06T04:00:00","date_gmt":"2018-06-06T04:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71178"},"modified":"2026-01-24T03:59:43","modified_gmt":"2026-01-24T03:59:43","slug":"pro-ezgc-chromatogram-modeler-4-refining-your-model-part-2-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3635-ja\/pro-ezgc-chromatogram-modeler-4-refining-your-model-part-2-japan","title":{"rendered":"Pro\u00a0EZGC Chromatogram Modeler\u306e\u6709\u52b9\u6d3b\u7528\u3010\u7b2c5\u56de\u30114\uff0e\u30e2\u30c7\u30eb\u6539\u826f\u65b9\u6cd5 Part 2"},"content":{"rendered":"\n<figure class=\"wp-block-embed is-type-video is-provider-youtube wp-block-embed-youtube wp-embed-aspect-4-3 wp-has-aspect-ratio\"><div class=\"wp-block-embed__wrapper\">\n<iframe loading=\"lazy\" title=\"Pro EZGC\u00ae Chromatogram Modeler: Refining your Model, Part 2 - Intermediate Use, Part 4 of 4\" width=\"720\" height=\"540\" src=\"https:\/\/www.youtube.com\/embed\/Lg-0oftka2g?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe>\n<\/div><\/figure>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-gallery has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"512\" height=\"373\" data-id=\"29853\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png\" alt=\"\" class=\"wp-image-29853\" style=\"width:165px;height:auto\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1.png 512w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-1-300x219.png 300w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"447\" height=\"528\" data-id=\"29859\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png\" alt=\"\" class=\"wp-image-29859\" style=\"width:111px;height:auto\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12.png 447w, https:\/\/discover.restek.com\/wp-content\/uploads\/VIDEO-SUBTITLES-JAPANESE-\uff12-254x300.png 254w\" sizes=\"auto, (max-width: 447px) 100vw, 447px\" \/><\/figure>\n<\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\"><\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size wp-block-paragraph\">YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Pro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler\u306e\u6709\u52b9\u6d3b\u7528<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306ePro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler\uff08\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30b7\u30df\u30e5\u30ec\u30fc\u30bf\u30fc\u3068\u3057\u3066\u3082\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\uff09\u306f\u3001\u30dd\u30ea\u30de\u30fc\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u7528\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u64cd\u4f5c\u304c\u30b7\u30f3\u30d7\u30eb\u3067\u3042\u308a\u306a\u304c\u3089\u3001\u9ad8\u5ea6\u306a\u30aa\u30d7\u30b7\u30e7\u30f3\u3082\u5099\u3048\u3066\u3044\u308b\u305f\u3081\u3001GC\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u5927\u304d\u306a\u52a9\u3051\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n<style>.wp-block-kadence-advancedbtn.kt-btns71178_646805-c9, .site .entry-content .wp-block-kadence-advancedbtn.kt-btns71178_646805-c9, .wp-block-kadence-advancedbtn.kb-btns71178_646805-c9, .site .entry-content .wp-block-kadence-advancedbtn.kb-btns71178_646805-c9{margin-top:var(--global-kb-spacing-sm, 1.5rem);margin-bottom:var(--global-kb-spacing-sm, 1.5rem);}.wp-block-kadence-advancedbtn.kb-btns71178_646805-c9{padding-top:0px;gap:var(--global-kb-gap-xs, 0.5rem );justify-content:flex-start;align-items:center;}.kt-btns71178_646805-c9 .kt-button{font-weight:normal;font-style:normal;}.kt-btns71178_646805-c9 .kt-btn-wrap-0{margin-right:5px;}.wp-block-kadence-advancedbtn.kt-btns71178_646805-c9 .kt-btn-wrap-0 .kt-button{color:#555555;border-color:#555555;}.wp-block-kadence-advancedbtn.kt-btns71178_646805-c9 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns71178_646805-c9 .kt-btn-wrap-0 .kt-button:focus{color:#ffffff;border-color:#444444;}.wp-block-kadence-advancedbtn.kt-btns71178_646805-c9 .kt-btn-wrap-0 .kt-button::before{display:none;}.wp-block-kadence-advancedbtn.kt-btns71178_646805-c9 .kt-btn-wrap-0 .kt-button:hover, .wp-block-kadence-advancedbtn.kt-btns71178_646805-c9 .kt-btn-wrap-0 .kt-button:focus{background:#444444;}<\/style>\n<div class=\"wp-block-kadence-advancedbtn kb-buttons-wrap kb-btns71178_646805-c9\"><style>ul.menu .wp-block-kadence-advancedbtn .kb-btn71178_63f756-c0.kb-button{width:initial;}.wp-block-kadence-advancedbtn .kb-btn71178_63f756-c0.kb-button{background:#23649e;font-size:16px;font-weight:700;border-top-left-radius:4px;border-top-right-radius:4px;border-bottom-right-radius:4px;border-bottom-left-radius:4px;padding:var(--kb-btn-padding);margin:var(--kb-btn-margin);padding-top:var(--global-kb-spacing-xxs, 0.5rem);padding-right:var(--global-kb-spacing-md, 2rem);padding-bottom:var(--global-kb-spacing-xxs, 0.5rem);padding-left:var(--global-kb-spacing-md, 2rem);box-shadow:none;}.wp-block-kadence-advancedbtn .kb-btn71178_63f756-c0.kb-button:hover, .wp-block-kadence-advancedbtn .kb-btn71178_63f756-c0.kb-button:focus{box-shadow:var(--kb-btn-shadow-hover, none);}<\/style><a class=\"kb-button kt-button button kb-btn71178_63f756-c0 kt-btn-size-small kt-btn-width-type-auto kb-btn-global-fill kt-btn-has-text-true kt-btn-has-svg-false wp-block-kadence-singlebtn\" href=\"https:\/\/ez.restek.com\/proezgc\" target=\"_blank\" rel=\"noreferrer noopener\"><span class=\"kt-btn-inner-text\">Get Started<\/span><\/a><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">Pro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler\u64cd\u4f5c\u65b9\u6cd5\u89e3\u8aac\u52d5\u753b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><a href=\"videos\/pro-ezgc-chromatogram-modeler-introduction\"><\/a><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3641-ja\/pro-ezgc-chromatogram-modeler-introduction-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3641-ja\/pro-ezgc-chromatogram-modeler-introduction-japan\" rel=\"noreferrer noopener\">\u3010\u7b2c1\u56de\u3011\u6982\u8981<\/a><\/li>\n\n\n\n<li><a href=\"videos\/pro-ezgc-chromatogram-modeler-1-entering-compound-lists\"><\/a><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3632-ja\/pro-ezgc-chromatogram-modeler-1-entering-compound-lists-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3632-ja\/pro-ezgc-chromatogram-modeler-1-entering-compound-lists-japan\" rel=\"noreferrer noopener\">\u3010\u7b2c2\u56de\u30111. \u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u5165\u529b\u65b9\u6cd5<\/a><\/li>\n\n\n\n<li><a href=\"videos\/pro-ezgc-chromatogram-modeler-2-interface-details\"><\/a><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3633-ja\/pro-ezgc-chromatogram-modeler-2-interface-details-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3633-ja\/pro-ezgc-chromatogram-modeler-2-interface-details-japan\" rel=\"noreferrer noopener\">\u3010\u7b2c3\u56de\u30112. \u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u8a73\u8aac<\/a><\/li>\n\n\n\n<li><a href=\"videos\/pro-ezgc-chromatogram-modeler-3-refining-your-model-part-1\"><\/a><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3634-ja\/pro-ezgc-chromatogram-modeler-3-refining-your-model-part-1-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3634-ja\/pro-ezgc-chromatogram-modeler-3-refining-your-model-part-1-japan\" rel=\"noreferrer noopener\">\u3010\u7b2c4\u56de\u30113. \u30e2\u30c7\u30eb\u6539\u826f\u65b9\u6cd5 Part 1<\/a><\/li>\n\n\n\n<li><a href=\"videos\/pro-ezgc-chromatogram-modeler-4-refining-your-model-part-2\"><\/a>\u3010\u7b2c5\u56de\u30114. \u30e2\u30c7\u30eb\u6539\u826f\u65b9\u6cd5 Part 2\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/li>\n\n\n\n<li><a href=\"videos\/pro-ezgc-chromatogram-modeler-5-using-multiple-libraries\"><\/a><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3636-ja\/pro-ezgc-chromatogram-modeler-5-using-multiple-libraries-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3636-ja\/pro-ezgc-chromatogram-modeler-5-using-multiple-libraries-japan\" rel=\"noreferrer noopener\">\u3010\u7b2c6\u56de\u30115. \u8907\u6570\u306e\u30e9\u30a4\u30d6\u30e9\u30ea\u5229\u7528\u65b9\u6cd5\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"videos\/pro-ezgc-chromatogram-modeler-6-global-resolution-constraints\"><\/a><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3637-ja\/pro-ezgc-chromatogram-modeler-6-global-resolution-constraints-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3637-ja\/pro-ezgc-chromatogram-modeler-6-global-resolution-constraints-japan\" rel=\"noreferrer noopener\">\u3010\u7b2c7\u56de\u30116. \u5168\u4f53\u7684\u5206\u96e2\u5ea6\u8981\u4ef6\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"videos\/pro-ezgc-chromatogram-modeler-7-compound-specific-resolution-constraints\"><\/a><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3638-ja\/pro-ezgc-chromatogram-modeler-7-compound-specific-resolution-constraints-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3638-ja\/pro-ezgc-chromatogram-modeler-7-compound-specific-resolution-constraints-japan\" rel=\"noreferrer noopener\">\u3010\u7b2c8\u56de\u30117. \u5316\u5408\u7269\u3054\u3068\u306e\u5206\u96e2\u5ea6\u8981\u4ef6\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"videos\/pro-ezgc-chromatogram-modeler-8-adding-oven-ramps\"><\/a><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3639-ja\/pro-ezgc-chromatogram-modeler-8-adding-oven-ramps-japan\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3639-ja\/pro-ezgc-chromatogram-modeler-8-adding-oven-ramps-japan\" rel=\"noreferrer noopener\">\u3010\u7b2c9\u56de\u30118. \u6607\u6e29\u30ec\u30fc\u30c8\u306e\u8ffd\u52a0\uff08\u65e5\u672c\u8a9e\u6e96\u5099\u4e2d\uff09<\/a><\/li>\n\n\n\n<li><a href=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3640-ja\/pro-ezgc-chromatogram-modeler-9-injection-considerations-japan\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/videos-ja\/gnav3640-ja\/pro-ezgc-chromatogram-modeler-9-injection-considerations-japan\">\u3010\u7b2c10\u56de\u30119. \u6ce8\u5165\u65b9\u6cd5\u5225\u306e\u691c\u8a0e\u4e8b\u9805<\/a><\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Gas Flow Parameter\u306e\u4e0a\u306b\u3001\u30ab\u30e9\u30e0\u60c5\u5831\u304c\u8868\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eee\u306b\u3001\u5b9f\u969b\u30e9\u30dc\u306b\u3042\u308bRtx-1\u30ab\u30e9\u30e0\u306e\u30b5\u30a4\u30ba\u304c\u3001\u30ab\u30e9\u30e0\u957730\u30e1\u30fc\u30c8\u30eb\u3001\u5185\u5f8432\u30df\u30ea\u30e1\u30fc\u30c8\u30eb\u3001\u819c\u539a5\u30df\u30af\u30ed\u30f3\u3067\u306f\u306a\u3044\u5834\u5408\u3001\u7d50\u679c\u306f\u3069\u3046\u306a\u308b\u3067\u3057\u3087\u3046\uff1f\u7570\u306a\u308b\u30b5\u30a4\u30ba\u306e\u30ab\u30e9\u30e0\u3067\u3082\u3001\u540c\u69d8\u306e\u5206\u96e2\u304c\u53ef\u80fd\u3067\u3057\u3087\u3046\u304b\uff1f\u5b9f\u969b\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u4e00\u90e8\u304c\u30ed\u30c3\u30af\u3055\u308c\u3066\u3044\u3066\u3082\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3084\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306f\u5909\u66f4\u53ef\u80fd\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001\u30e9\u30dc\u306b\u30ab\u30e9\u30e0\u957730\u30e1\u30fc\u30c8\u30eb\u3001\u5185\u5f840.25\u30df\u30ea\u30e1\u30fc\u30c8\u30eb\u3001\u819c\u539a5\u30df\u30af\u30ed\u30f3\u306e\u30ab\u30e9\u30e0\u304c\u3042\u308b\u3068\u3057\u307e\u3059\u3002MS\u30e6\u30fc\u30b6\u30fc\u3068\u3057\u3066\u306f\u3001\u3053\u306e\u819c\u539a\u306f\u63ee\u767a\u6027\u5316\u5408\u7269\u306b\u306f\u3084\u3084\u8584\u3044\u306e\u3067\u3001\u308f\u3056\u308f\u3056MS\u306b\u63a5\u7d9a\u3057\u3066\u8a66\u3059\u3079\u304d\u304b\u8ff7\u3046\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002Modeler\u4e0a\u3067\u306a\u3089\u3001\u4f55\u306e\u30ea\u30b9\u30af\u3082\u306a\u3057\u306b\u8a66\u3059\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3084\u3063\u3066\u307f\u307e\u3057\u3087\u3046\uff01<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u3001\u30c9\u30ed\u30c3\u30d7\u30c0\u30a6\u30f3\u30ea\u30b9\u30c8\u304b\u3089\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u9078\u629e\u3057\u307e\u3059\u300230\u30010.25\u30015\u3092\u63a2\u3057\u307e\u3059\u3002\u3042\u3001\u3053\u3053\u306b\u3042\u308a\u307e\u3057\u305f\uff01\u77e5\u3063\u3066\u304a\u3044\u3066\u9802\u304d\u305f\u3044\u306e\u306f\u3001\u3053\u3053\u306b\u30ea\u30b9\u30c8\u30a2\u30c3\u30d7\u3055\u308c\u3066\u3044\u308b\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306eRtx-1\u306f\u3001\u3059\u3079\u3066\u6a19\u6e96\u54c1\u3068\u3057\u3066\u8cfc\u5165\u53ef\u80fd\u3067\u3042\u308b\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u3053\u306e\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306e\u30e2\u30c7\u30eb\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u5b9f\u969b\u3001\u819c\u539a\u304c\u8584\u3044Rtx-1\u306e\u30e2\u30c7\u30eb\u3067\u3082\u3001\u601d\u3044\u306e\u307b\u304b\u826f\u597d\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u304cPro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler\u306e\u5f37\u307f\u3067\u3042\u308a\u3001\u7121\u6599\u304b\u3064\u8fc5\u901f\u306b\u4eee\u8aac\u691c\u8a3c\u304c\u53ef\u80fd\u306a\u89e3\u6c7a\u7b56\u3067\u3042\u308b\u7406\u7531\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3053\u3067\u8a66\u3057\u305f\u30b1\u30fc\u30b9\u3067\u306f\u3001\u5206\u6790\u6642\u9593\u306e\u5927\u5e45\u306a\u77ed\u7e2e\u3060\u3051\u3067\u306a\u304f\u3001\u3059\u3079\u3066\u306e\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u9593\u3067\u306e\u5341\u5206\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u305d\u306e\u4e0a\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3092\u8cfc\u5165\u3059\u308b\u5fc5\u8981\u3082\u3042\u308a\u307e\u305b\u3093\u3002\u3053\u308c\u3060\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u5909\u66f4\u3059\u308b\u3068\u3001\u30ab\u30e9\u30e0\u5185\u5f840.25\u30df\u30ea\u30e1\u30fc\u30c8\u30eb\u306e\u5834\u5408\u306b\u6700\u9069\u306a\u52b9\u7387\u3068\u306a\u308b\u3088\u3046\u3001\u30ab\u30e9\u30e0\u6d41\u91cf\u306f\u81ea\u52d5\u7684\u306b\u8a2d\u5b9a\u3055\u308c\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u306f\u81ea\u52d5\u7684\u306b\u66f4\u65b0\u3055\u308c\u307e\u305b\u3093\u3002<strong>\u300cRefine Oven Program\uff08\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u8abf\u6574\uff09\u300d<\/strong>\u30dc\u30bf\u30f3\u3092\u4f7f\u3063\u3066\u6700\u9069\u5316\u3092\u9032\u3081\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3069\u3046\u3067\u3057\u3087\u3046\u304b\u3002\u8abf\u6574\u304c\u8907\u6570\u56de\u884c\u308f\u308c\u305f\u306e\u304c\u304a\u5206\u304b\u308a\u3067\u3057\u3087\u3046\u3002\u4f55\u56de\u304b\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u6700\u9069\u5316\u3092\u884c\u3063\u3066\u3001\u5206\u6790\u6642\u9593\u30924\u5206\u4ee5\u4e0b\u306b\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30e2\u30c7\u30eb\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3068\u3066\u3082\u826f\u3055\u305d\u3046\u3067\u3059\u306d\u3002\u6700\u521d\u306e3\u3064\u306e\u30d4\u30fc\u30af\u306f\u4f9d\u7136\u3068\u3057\u3066\u826f\u597d\u306b\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3084\u3001\u30d4\u30fc\u30af\u306e\u5e83\u304c\u308a\u306e\u5f71\u97ff\u3092\u53d7\u3051\u308b\u3053\u3068\u306e\u591a\u3044\u4ed6\u306e\u6ce8\u5165\u6cd5\u3067\u3082\u3001\u30d4\u30fc\u30af\u5206\u96e2\u306e\u7dad\u6301\u304c\u5341\u5206\u306b\u671f\u5f85\u3067\u304d\u307e\u3059\u3002\u4ed6\u306e\u7b87\u6240\u3082\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002\u30d4\u30fc\u30af4\u30015\u30016\u3067\u3059\u3002\u30d4\u30fc\u30af4\u306e\u30a4\u30aa\u30f3\u3092\u30dd\u30c3\u30d7\u30a2\u30c3\u30d7\u753b\u9762\u3067\u898b\u3066\u307f\u307e\u3059\u3002\u4e3b\u8981\u306a\u30a4\u30aa\u30f3\u306f61\u300196\u300198\u3001100\u3067\u3042\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u61f8\u5ff5\u3055\u308c\u308b\u306e\u306f\u3001\u3082\u3057\u30d4\u30fc\u30af\u306e\u5e83\u304c\u308a\u304c\u5927\u304d\u304f\u306a\u3063\u305f\u3089\u3001\u30d4\u30fc\u30af4\u304c\u30d4\u30fc\u30af5\u3084\u30d4\u30fc\u30af6\u306b\u91cd\u306a\u3063\u305f\u308a\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u3057\u305f\u308a\u3059\u308b\u306e\u3067\u306f\uff1f\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u30d4\u30fc\u30af5\u3068\u30d4\u30fc\u30af6\u306e\u30a4\u30aa\u30f3\u3082\u540c\u69d8\u306b\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3053\u308c\u306f\u30d4\u30fc\u30af6\u306e\u30a4\u30aa\u30f3\u3067\u3059\u304c\u3001\u3053\u306e\u4e0a\u306b\u30d4\u30fc\u30af5\u3092\u91cd\u306d\u3066\u8868\u793a\u3057\u3066\u307f\u307e\u3059\u3002\u30d4\u30fc\u30af5\u3068\u30d4\u30fc\u30af6\u306e\u4e3b\u8981\u306a\u30a4\u30aa\u30f3\u306f\u300143\u300157\u300183\u300185\u3067\u3042\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u30d4\u30fc\u30af\u306e\u5e83\u304c\u308a\u304c\u30d4\u30fc\u30af4\u307e\u3067\u5927\u304d\u304f\u306a\u308a\u3001\u30d4\u30fc\u30af5\u3084\u30d4\u30fc\u30af6\u306b\u91cd\u306a\u3063\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u3067\u3082\u3001\u5fc5\u8981\u3067\u3042\u308c\u3070\u3001\u5404\u30d4\u30fc\u30af\u3054\u3068\u306b\u7279\u5fb4\u7684\u306a\u30a4\u30aa\u30f3\u3092\u9078\u3073\u51fa\u3059\u3053\u3068\u306f\u53ef\u80fd\u3060\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u30aa\u30fc\u30d6\u30f3\u6607\u6e29\u30ec\u30fc\u30c8\u306f\u3001\u73fe\u5728\u6bce\u520630\u5ea6\u307e\u3067\u5f15\u304d\u4e0a\u3052\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u6700\u9069\u5316\u3067\u304d\u308b\u6700\u5927\u5024\u3067\u3059\u3002\u5b9f\u969b\u3001\u307b\u3068\u3093\u3069\u306eGC\u88c5\u7f6e\u306f\u6bce\u520630\u5ea6\u306e\u6607\u6e29\u30ec\u30fc\u30c8\u3067\u3082\u3001\u7d04300\u5ea6\u307e\u3067\u5b89\u5b9a\u3057\u3066\u52d5\u4f5c\u3055\u305b\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u88c5\u7f6e\u306e\u8a31\u5bb9\u7bc4\u56f2\u5185\u306b\u3057\u3063\u304b\u308a\u53ce\u307e\u3063\u3066\u3044\u308b\u306e\u3067\u3001\u3059\u3079\u3066\u554f\u984c\u306a\u304f\u9032\u3093\u3067\u3044\u308b\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002\u3053\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u975e\u5e38\u306b\u826f\u597d\u306a\u306e\u3067\u4fdd\u5b58\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002\u65e2\u306b\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u540d\u524d\u304c\u3042\u308b\u306e\u3067\u3001\u5225\u540d\u3092\u4ed8\u3051\u3066\u4fdd\u5b58\u3057\u307e\u3059\u3002\u305d\u3046\u3057\u3066\u304a\u3051\u3070\u3001\u30aa\u30ea\u30b8\u30ca\u30eb\u3068\u306e\u6bd4\u8f03\u3082\u53ef\u80fd\u3067\u3059\u3002\u65b9\u6cd5\u306f\u3001<strong>\u300cSave a Copy\uff08\u540d\u524d\u3092\u4ed8\u3051\u3066\u4fdd\u5b58\uff09\u300d<\/strong>\u3092\u62bc\u3057\u3066\u3001\u540d\u524d\u3092\u5909\u3048\u308b\u3060\u3051\u3067\u3059\u3002\u65b0\u3057\u3044\u540d\u524d\u306f\u3001Really Fast Volatiles\u3092\u8ffd\u52a0\u3059\u308b\u306e\u3067\u3069\u3046\u3067\u3057\u3087\u3046\u304b\u3002\u826f\u3055\u305d\u3046\u306a\u306e\u3067\u3001\u65b0\u3057\u3044\u540d\u524d\u3067OK\u3092\u62bc\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001<strong>\u300cSave\uff08\u4fdd\u5b58\uff09\u300d<\/strong>\u30dc\u30bf\u30f3\u3092\u62bc\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30a4\u30b9\u8868\u793a\u9818\u57df\u306e\u4e00\u756a\u53f3\u3001<strong>\u300cMy&nbsp;<em>EZ<\/em>GC\u300d<\/strong>\u30bf\u30d6\u306b\u306f\u3001\u3053\u308c\u307e\u3067\u306b\u4fdd\u5b58\u3057\u305f\u3059\u3079\u3066\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u8868\u793a\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u6bd4\u8f03\u3059\u308b\u306e\u304c\u7c21\u5358\u3067\u3059\u3002Really Fast Volatiles\u3068less-fast volatile\u3068\u3092\u6bd4\u8f03\u3059\u308c\u3070\u3001\u5206\u6790\u6642\u9593\u304c\u5927\u5e45\u306b\u77ed\u7e2e\u3055\u308c\u3066\u3044\u306a\u304c\u3089\u3082\u3001\u5206\u96e2\u306f\u7dad\u6301\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u4e00\u76ee\u3067\u308f\u304b\u308a\u307e\u3059\u3002\u6570\u5206\u3067\u3067\u304d\u305f\u4ed5\u4e8b\u3068\u3057\u3066\u306f\u3001\u304b\u306a\u308a\u826f\u3044\u3082\u306e\u3060\u3068\u8a00\u3048\u308b\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002Pro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u30e9\u30dc\u3067\u9577\u671f\u9593\u653e\u7f6e\u3055\u308c\u3066\u3044\u305f\u30ab\u30e9\u30e0\u3067\u3082\u3001\u5805\u7262\u3067\u8fc5\u901f\u306a\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u304c\u53ef\u80fd\u3067\u3057\u305f\u3002\u3055\u3089\u306b\u7d20\u6674\u3089\u3057\u3044\u306e\u306f\u3001\u3053\u306e\u958b\u767a\u304c\u3001\u308f\u305a\u304b\u6570\u5206\u3067\u3001GC\u88c5\u7f6e\u306b\u89e6\u308c\u305a\u3001\u6a19\u6e96\u8a66\u6599\u3092\u8abf\u88fd\u305b\u305a\u306b\u3067\u304d\u305f\u3053\u3068\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u3053\u307e\u3067\u306e\u52d5\u753b\u3092\u632f\u308a\u8fd4\u308a\u307e\u3059\u3002\u6700\u521d\u306b\u3001\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u5165\u529b\u65b9\u6cd5\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u30ab\u30e9\u30e0\u8cfc\u5165\u3082\u691c\u8a0e\u53ef\u80fd\u3067\u6700\u9069\u306a\u65b9\u6cd5\u3092\u6c42\u3081\u3066\u3044\u308b\u306a\u3089\u3001<strong>\u300cSearch by Name\uff08\u5316\u5408\u7269\u3067\u691c\u7d22\uff09\u300d<\/strong>\u306e\u4f7f\u7528\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u73fe\u5728\u30e9\u30dc\u306b\u3042\u308b\u30ab\u30e9\u30e0\u3067\u306e\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u8a08\u753b\u3057\u3066\u3044\u308b\u306a\u3089\u3001<strong>\u300cSearch by Phase\uff08\u56fa\u5b9a\u76f8\u3067\u691c\u7d22\uff09\u300d<\/strong>\u306e\u4f7f\u7528\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u306b\u3064\u3044\u3066\u3082\u8a73\u3057\u304f\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u30e2\u30c7\u30eb\u8868\u793a\u9818\u57df\u306e\u60c5\u5831\u306f\u3001\u6642\u9593\u7bc0\u7d04\u306b\u975e\u5e38\u306b\u6709\u7528\u3067\u3059\u3002MS\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u52b9\u7387\u5316\u306b\u969b\u3057\u3001\u3053\u308c\u4ee5\u4e0a\u306e\u50cd\u304d\u3092\u3059\u308b\u3082\u306e\u306f\u4ed6\u306b\u306a\u3044\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002<strong>\u300cCondition\uff08\u5206\u6790\u6761\u4ef6\uff09\u300d<\/strong>\u30bf\u30d6\u306b\u95a2\u3059\u308b\u8aac\u660e\u306b\u306f\u591a\u304f\u306e\u6642\u9593\u3092\u4f7f\u3044\u307e\u3057\u305f\u3002\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u306f2\u3064\u3067\u3059\u3002\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u81ea\u52d5\u3067\u6700\u9069\u5316\u3059\u308b\u306e\u306f\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u307f\u3067\u3001\u4ed6\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u306b\u3064\u3044\u3066\u306f\u3001\u81ea\u7531\u306b\u5909\u66f4\u304c\u53ef\u80fd\u3067\u3059\u3002\u3053\u306e\u5909\u66f4\u306b\u6e96\u3058\u3066\u3001\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u6700\u9069\u5316\u3057\u3066\u304f\u308c\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u3053\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3067\u306f\u7dda\u901f\u5ea6\u3068\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u304c\u9023\u52d5\u3057\u3066\u3044\u306a\u3044\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u7dda\u901f\u5ea6\u304c\u5909\u308f\u308b\u306e\u306f\u3044\u3064\u3067\u3082\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3068\u3001\u6d41\u91cf\u3068\u304c\u5909\u66f4\u3055\u308c\u305f\u3068\u304d\u3067\u3059\u3002\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u3082\u305d\u308c\u306b\u6cbf\u3063\u3066\u6700\u9069\u5316\u3055\u308c\u307e\u3059\u3002\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306e\u8a2d\u5b9a\u5909\u66f4\u304a\u3088\u3073\u6d41\u91cf\u3084\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u8abf\u6574\u5f8c\u306b\u5206\u96e2\u304c\u8457\u3057\u304f\u4f4e\u4e0b\u3057\u305f\u5834\u5408\u3001\u63a8\u5968\u3055\u308c\u308b\u306e\u306f\u3001\u2460<strong>\u300cUndo\uff08\u5143\u306b\u623b\u3059\uff09\u300d<\/strong>\u3067\u76f4\u524d\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306b\u623b\u308a\u3001\u2461<em>EZ<\/em>GC method translator\u3092\u4f7f\u7528\u3057\u3066\u3001\u65b0\u305f\u306a\u6761\u4ef6\u306b\u9069\u3057\u305f\u65b0\u3057\u3044\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u4f5c\u6210\u3057\u3001\u2462\u3053\u308c\u3092\u57fa\u306b\u3057\u305f\u6700\u9069\u5316\u3092\u884c\u3046\u3001\u3068\u3044\u3046\u624b\u9806\u306e\u5b9f\u884c\u3067\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u65b0\u305f\u306b\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u306f\u53ef\u80fd\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u3053\u306e\u624b\u9806\u306e\u5b9f\u884c\u304c\u5fc5\u8981\u306a\u30b1\u30fc\u30b9\u306f\u7a00\u3067\u3059\u30029\u52729\u5206\u3001<strong>\u300cRefine\uff08\u8abf\u6574\uff09\u300d<\/strong>\u30dc\u30bf\u30f3\u3092\u4f7f\u3046\u3060\u3051\u3067\u5341\u5206\u826f\u597d\u306a\u5206\u96e2\u306f\u5f97\u3089\u308c\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d41\u91cf\u3084\u7a2e\u985e\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u5909\u66f4\u3057\u305f\u5834\u5408\u3067\u3042\u3063\u3066\u3082\u540c\u69d8\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Pro&nbsp;<em>EZ<\/em>GC Chromatogram Modeler\u306e\u3055\u3089\u306b\u8a73\u3057\u3044\u60c5\u5831\u306f\u3001\u52d5\u753b\u30b7\u30ea\u30fc\u30ba\u7b2c\u4e09\u5f3e\u3067\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u7b2c\u4e09\u5f3e\u3067\u306f\u5206\u96e2\u5ea6\u8981\u4ef6\u306b\u3064\u3044\u3066\u8a73\u3057\u304f\u89e3\u8aac\u3057\u3066\u3044\u307e\u3059\u3002MS\u5206\u6790\u306b\u969b\u3057\u3066\u3001\u8003\u616e\u3059\u3079\u304d\u70b9\u306b\u3064\u3044\u3066\u3082\u8a73\u8ff0\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u3001\u8a73\u7d30\u306a\u70b9\u306b\u307e\u3067\u8a00\u53ca\u3057\u305f\u30d8\u30eb\u30d7\u30d5\u30a1\u30a4\u30eb\u3082\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u3054\u4e0d\u660e\u70b9\u306b\u3064\u3044\u3066\u306f\u3001\u307e\u305a\u30d8\u30eb\u30d7\u30d5\u30a1\u30a4\u30eb\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u305c\u3072\u3054\u4e00\u8aad\u3044\u305f\u3060\u304d\u305f\u3044\u306e\u306f\u3001<em>EZ<\/em>GC Suite\u30d6\u30ed\u30b0\u3067\u3059\u3002\u3053\u3053\u3067\u304a\u77e5\u3089\u305b\u3059\u308b\u6700\u65b0\u60c5\u5831\u306b\u306f\u3001\u65b0\u3057\u3044\u30e9\u30a4\u30d6\u30e9\u30ea\u3084\u30b7\u30e7\u30fc\u30c8\u30ab\u30c3\u30c8\u3001Pro&nbsp;<em>EZ<\/em>GC Modeler\u306e\u9069\u7528\u4f8b\u306a\u3069\u304c\u3042\u308a\u307e\u3059\u3002\u3082\u3057\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u306b\u76ee\u7684\u306e\u5316\u5408\u7269\u304c\u542b\u307e\u308c\u3066\u3044\u306a\u3051\u308c\u3070\u3001Restek\u306e\u6280\u8853\u30b5\u30fc\u30d3\u30b9\u3078\u304a\u6c17\u8efd\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002\u5206\u6790\u958b\u59cb\u6642\u304b\u3089\u3055\u307e\u3056\u307e\u306a\u30b5\u30dd\u30fc\u30c8\u3092\u3054\u63d0\u4f9b\u3044\u305f\u3057\u307e\u3059\u3002\u3054\u8996\u8074\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002Restek\u304c\u76ee\u6307\u3057\u305f\u306e\u306f\u3001\u30e9\u30dc\u3067\u306e\u4f5c\u696d\u3092\u30b7\u30f3\u30d7\u30eb\u306b\u3057\u3066\u3001\u30b4\u30fc\u30eb\u306b\u4e00\u76f4\u7dda\u306b\u5411\u304b\u3048\u308b\u74b0\u5883\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u3053\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u3001\u305d\u308c\u3092\u5b9f\u73fe\u3067\u304d\u308b\u3068\u601d\u3063\u3066\u3044\u307e\u3059\u3002\u3054\u8cea\u554f\u7b49\u3054\u3056\u3044\u307e\u3057\u305f\u3089\u3001\u3069\u3046\u305e\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>YouTube\u753b\u9762\u53f3\u4e0b\u306b\u3042\u308b\u8a2d\u5b9a\u30dc\u30bf\u30f3\u2699\u304b\u3089Subtitles\/CC\u3092\u9078\u3073\u3001Japanese\u306b\u30c1\u30a7\u30c3\u30af\u3092\u5165\u308c\u308b\u3068\u65e5\u672c\u8a9e\u5b57\u5e55\u3042\u308a\u3067\u52d5\u753b\u3092\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002 Pro&nbsp;EZGC Chromatogram Modeler\u306e\u6709\u52b9\u6d3b\u7528 Restek\u306ePro&nbsp;EZGC Chromatogram Modeler\uff08\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30b7\u30df\u30e5\u30ec\u30fc\u30bf\u30fc\u3068\u3057\u3066\u3082\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\uff09\u306f\u3001\u30dd\u30ea\u30de\u30fc\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u7528\u306b\u8a2d\u8a08\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u64cd\u4f5c\u304c\u30b7\u30f3\u30d7\u30eb\u3067\u3042\u308a\u306a\u304c\u3089\u3001\u9ad8\u5ea6\u306a\u30aa\u30d7\u30b7\u30e7\u30f3\u3082\u5099\u3048\u3066\u3044\u308b\u305f\u3081\u3001GC\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u5927\u304d\u306a\u52a9\u3051\u3068\u306a\u308a\u307e\u3059\u3002 Pro&nbsp;EZGC Chromatogram Modeler\u64cd\u4f5c\u65b9\u6cd5\u89e3\u8aac\u52d5\u753b \u30c8\u30e9\u30f3\u30b9\u30af\u30ea\u30d7\u30c8 Gas Flow Parameter\u306e\u4e0a\u306b\u3001\u30ab\u30e9\u30e0\u60c5\u5831\u304c\u8868\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4eee\u306b\u3001\u5b9f\u969b\u30e9\u30dc\u306b\u3042\u308bRtx-1\u30ab\u30e9\u30e0\u306e\u30b5\u30a4\u30ba\u304c\u3001\u30ab\u30e9\u30e0\u957730\u30e1\u30fc\u30c8\u30eb\u3001\u5185\u5f8432\u30df\u30ea\u30e1\u30fc\u30c8\u30eb\u3001\u819c\u539a5\u30df\u30af\u30ed\u30f3\u3067\u306f\u306a\u3044\u5834\u5408\u3001\u7d50\u679c\u306f\u3069\u3046\u306a\u308b\u3067\u3057\u3087\u3046\uff1f\u7570\u306a\u308b\u30b5\u30a4\u30ba\u306e\u30ab\u30e9\u30e0\u3067\u3082\u3001\u540c\u69d8\u306e\u5206\u96e2\u304c\u53ef\u80fd\u3067\u3057\u3087\u3046\u304b\uff1f\u5b9f\u969b\u3001\u30d1\u30e9\u30e1\u30fc\u30bf\u306e\u4e00\u90e8\u304c\u30ed\u30c3\u30af\u3055\u308c\u3066\u3044\u3066\u3082\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3084\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306f\u5909\u66f4\u53ef\u80fd\u3067\u3059\u3002\u4f8b\u3048\u3070\u3001\u30e9\u30dc\u306b\u30ab\u30e9\u30e0\u957730\u30e1\u30fc\u30c8\u30eb\u3001\u5185\u5f840.25\u30df\u30ea\u30e1\u30fc\u30c8\u30eb\u3001\u819c\u539a5\u30df\u30af\u30ed\u30f3\u306e\u30ab\u30e9\u30e0\u304c\u3042\u308b\u3068\u3057\u307e\u3059\u3002MS\u30e6\u30fc\u30b6\u30fc\u3068\u3057\u3066\u306f\u3001\u3053\u306e\u819c\u539a\u306f\u63ee\u767a\u6027\u5316\u5408\u7269\u306b\u306f\u3084\u3084\u8584\u3044\u306e\u3067\u3001\u308f\u3056\u308f\u3056MS\u306b\u63a5\u7d9a\u3057\u3066\u8a66\u3059\u3079\u304d\u304b\u8ff7\u3046\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002Modeler\u4e0a\u3067\u306a\u3089\u3001\u4f55\u306e\u30ea\u30b9\u30af\u3082\u306a\u3057\u306b\u8a66\u3059\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3084\u3063\u3066\u307f\u307e\u3057\u3087\u3046\uff01 \u307e\u305a\u3001\u30c9\u30ed\u30c3\u30d7\u30c0\u30a6\u30f3\u30ea\u30b9\u30c8\u304b\u3089\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u9078\u629e\u3057\u307e\u3059\u300230\u30010.25\u30015\u3092\u63a2\u3057\u307e\u3059\u3002\u3042\u3001\u3053\u3053\u306b\u3042\u308a\u307e\u3057\u305f\uff01\u77e5\u3063\u3066\u304a\u3044\u3066\u9802\u304d\u305f\u3044\u306e\u306f\u3001\u3053\u3053\u306b\u30ea\u30b9\u30c8\u30a2\u30c3\u30d7\u3055\u308c\u3066\u3044\u308b\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306eRtx-1\u306f\u3001\u3059\u3079\u3066\u6a19\u6e96\u54c1\u3068\u3057\u3066\u8cfc\u5165\u53ef\u80fd\u3067\u3042\u308b\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u3053\u306e\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306e\u30e2\u30c7\u30eb\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u5b9f\u969b\u3001\u819c\u539a\u304c\u8584\u3044Rtx-1\u306e\u30e2\u30c7\u30eb\u3067\u3082\u3001\u601d\u3044\u306e\u307b\u304b\u826f\u597d\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u3053\u308c\u304cPro&nbsp;EZGC Chromatogram Modeler\u306e\u5f37\u307f\u3067\u3042\u308a\u3001\u7121\u6599\u304b\u3064\u8fc5\u901f\u306b\u4eee\u8aac\u691c\u8a3c\u304c\u53ef\u80fd\u306a\u89e3\u6c7a\u7b56\u3067\u3042\u308b\u7406\u7531\u3067\u3059\u3002 \u3053\u3053\u3067\u8a66\u3057\u305f\u30b1\u30fc\u30b9\u3067\u306f\u3001\u5206\u6790\u6642\u9593\u306e\u5927\u5e45\u306a\u77ed\u7e2e\u3060\u3051\u3067\u306a\u304f\u3001\u3059\u3079\u3066\u306e\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u9593\u3067\u306e\u5341\u5206\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u305d\u306e\u4e0a\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u3092\u8cfc\u5165\u3059\u308b\u5fc5\u8981\u3082\u3042\u308a\u307e\u305b\u3093\u3002\u3053\u308c\u3060\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u5909\u66f4\u3059\u308b\u3068\u3001\u30ab\u30e9\u30e0\u5185\u5f840.25\u30df\u30ea\u30e1\u30fc\u30c8\u30eb\u306e\u5834\u5408\u306b\u6700\u9069\u306a\u52b9\u7387\u3068\u306a\u308b\u3088\u3046\u3001\u30ab\u30e9\u30e0\u6d41\u91cf\u306f\u81ea\u52d5\u7684\u306b\u8a2d\u5b9a\u3055\u308c\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u306f\u81ea\u52d5\u7684\u306b\u66f4\u65b0\u3055\u308c\u307e\u305b\u3093\u3002\u300cRefine Oven Program\uff08\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u8abf\u6574\uff09\u300d\u30dc\u30bf\u30f3\u3092\u4f7f\u3063\u3066\u6700\u9069\u5316\u3092\u9032\u3081\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3069\u3046\u3067\u3057\u3087\u3046\u304b\u3002\u8abf\u6574\u304c\u8907\u6570\u56de\u884c\u308f\u308c\u305f\u306e\u304c\u304a\u5206\u304b\u308a\u3067\u3057\u3087\u3046\u3002\u4f55\u56de\u304b\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u6700\u9069\u5316\u3092\u884c\u3063\u3066\u3001\u5206\u6790\u6642\u9593\u30924\u5206\u4ee5\u4e0b\u306b\u77ed\u7e2e\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002 \u30e2\u30c7\u30eb\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3068\u3066\u3082\u826f\u3055\u305d\u3046\u3067\u3059\u306d\u3002\u6700\u521d\u306e3\u3064\u306e\u30d4\u30fc\u30af\u306f\u4f9d\u7136\u3068\u3057\u3066\u826f\u597d\u306b\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u6ce8\u5165\u3084\u3001\u30d4\u30fc\u30af\u306e\u5e83\u304c\u308a\u306e\u5f71\u97ff\u3092\u53d7\u3051\u308b\u3053\u3068\u306e\u591a\u3044\u4ed6\u306e\u6ce8\u5165\u6cd5\u3067\u3082\u3001\u30d4\u30fc\u30af\u5206\u96e2\u306e\u7dad\u6301\u304c\u5341\u5206\u306b\u671f\u5f85\u3067\u304d\u307e\u3059\u3002\u4ed6\u306e\u7b87\u6240\u3082\u898b\u3066\u3044\u304d\u307e\u3057\u3087\u3046\u3002\u30d4\u30fc\u30af4\u30015\u30016\u3067\u3059\u3002\u30d4\u30fc\u30af4\u306e\u30a4\u30aa\u30f3\u3092\u30dd\u30c3\u30d7\u30a2\u30c3\u30d7\u753b\u9762\u3067\u898b\u3066\u307f\u307e\u3059\u3002\u4e3b\u8981\u306a\u30a4\u30aa\u30f3\u306f61\u300196\u300198\u3001100\u3067\u3042\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u61f8\u5ff5\u3055\u308c\u308b\u306e\u306f\u3001\u3082\u3057\u30d4\u30fc\u30af\u306e\u5e83\u304c\u308a\u304c\u5927\u304d\u304f\u306a\u3063\u305f\u3089\u3001\u30d4\u30fc\u30af4\u304c\u30d4\u30fc\u30af5\u3084\u30d4\u30fc\u30af6\u306b\u91cd\u306a\u3063\u305f\u308a\u3001\u30c6\u30fc\u30ea\u30f3\u30b0\u3057\u305f\u308a\u3059\u308b\u306e\u3067\u306f\uff1f\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u30d4\u30fc\u30af5\u3068\u30d4\u30fc\u30af6\u306e\u30a4\u30aa\u30f3\u3082\u540c\u69d8\u306b\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u3087\u3046\u3002\u3053\u308c\u306f\u30d4\u30fc\u30af6\u306e\u30a4\u30aa\u30f3\u3067\u3059\u304c\u3001\u3053\u306e\u4e0a\u306b\u30d4\u30fc\u30af5\u3092\u91cd\u306d\u3066\u8868\u793a\u3057\u3066\u307f\u307e\u3059\u3002\u30d4\u30fc\u30af5\u3068\u30d4\u30fc\u30af6\u306e\u4e3b\u8981\u306a\u30a4\u30aa\u30f3\u306f\u300143\u300157\u300183\u300185\u3067\u3042\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u30d4\u30fc\u30af\u306e\u5e83\u304c\u308a\u304c\u30d4\u30fc\u30af4\u307e\u3067\u5927\u304d\u304f\u306a\u308a\u3001\u30d4\u30fc\u30af5\u3084\u30d4\u30fc\u30af6\u306b\u91cd\u306a\u3063\u3066\u3057\u307e\u3063\u305f\u5834\u5408\u3067\u3082\u3001\u5fc5\u8981\u3067\u3042\u308c\u3070\u3001\u5404\u30d4\u30fc\u30af\u3054\u3068\u306b\u7279\u5fb4\u7684\u306a\u30a4\u30aa\u30f3\u3092\u9078\u3073\u51fa\u3059\u3053\u3068\u306f\u53ef\u80fd\u3060\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u30aa\u30fc\u30d6\u30f3\u6607\u6e29\u30ec\u30fc\u30c8\u306f\u3001\u73fe\u5728\u6bce\u520630\u5ea6\u307e\u3067\u5f15\u304d\u4e0a\u3052\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u6700\u9069\u5316\u3067\u304d\u308b\u6700\u5927\u5024\u3067\u3059\u3002\u5b9f\u969b\u3001\u307b\u3068\u3093\u3069\u306eGC\u88c5\u7f6e\u306f\u6bce\u520630\u5ea6\u306e\u6607\u6e29\u30ec\u30fc\u30c8\u3067\u3082\u3001\u7d04300\u5ea6\u307e\u3067\u5b89\u5b9a\u3057\u3066\u52d5\u4f5c\u3055\u305b\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3064\u307e\u308a\u3001\u88c5\u7f6e\u306e\u8a31\u5bb9\u7bc4\u56f2\u5185\u306b\u3057\u3063\u304b\u308a\u53ce\u307e\u3063\u3066\u3044\u308b\u306e\u3067\u3001\u3059\u3079\u3066\u554f\u984c\u306a\u304f\u9032\u3093\u3067\u3044\u308b\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002\u3053\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u975e\u5e38\u306b\u826f\u597d\u306a\u306e\u3067\u4fdd\u5b58\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002\u65e2\u306b\u30aa\u30ea\u30b8\u30ca\u30eb\u306e\u540d\u524d\u304c\u3042\u308b\u306e\u3067\u3001\u5225\u540d\u3092\u4ed8\u3051\u3066\u4fdd\u5b58\u3057\u307e\u3059\u3002\u305d\u3046\u3057\u3066\u304a\u3051\u3070\u3001\u30aa\u30ea\u30b8\u30ca\u30eb\u3068\u306e\u6bd4\u8f03\u3082\u53ef\u80fd\u3067\u3059\u3002\u65b9\u6cd5\u306f\u3001\u300cSave a Copy\uff08\u540d\u524d\u3092\u4ed8\u3051\u3066\u4fdd\u5b58\uff09\u300d\u3092\u62bc\u3057\u3066\u3001\u540d\u524d\u3092\u5909\u3048\u308b\u3060\u3051\u3067\u3059\u3002\u65b0\u3057\u3044\u540d\u524d\u306f\u3001Really Fast Volatiles\u3092\u8ffd\u52a0\u3059\u308b\u306e\u3067\u3069\u3046\u3067\u3057\u3087\u3046\u304b\u3002\u826f\u3055\u305d\u3046\u306a\u306e\u3067\u3001\u65b0\u3057\u3044\u540d\u524d\u3067OK\u3092\u62bc\u3057\u307e\u3059\u3002\u305d\u306e\u5f8c\u3001\u300cSave\uff08\u4fdd\u5b58\uff09\u300d\u30dc\u30bf\u30f3\u3092\u62bc\u3057\u307e\u3059\u3002 \u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30a4\u30b9\u8868\u793a\u9818\u57df\u306e\u4e00\u756a\u53f3\u3001\u300cMy&nbsp;EZGC\u300d\u30bf\u30d6\u306b\u306f\u3001\u3053\u308c\u307e\u3067\u306b\u4fdd\u5b58\u3057\u305f\u3059\u3079\u3066\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u8868\u793a\u3055\u308c\u3066\u3044\u308b\u306e\u3067\u3001\u6bd4\u8f03\u3059\u308b\u306e\u304c\u7c21\u5358\u3067\u3059\u3002Really Fast Volatiles\u3068less-fast volatile\u3068\u3092\u6bd4\u8f03\u3059\u308c\u3070\u3001\u5206\u6790\u6642\u9593\u304c\u5927\u5e45\u306b\u77ed\u7e2e\u3055\u308c\u3066\u3044\u306a\u304c\u3089\u3082\u3001\u5206\u96e2\u306f\u7dad\u6301\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u4e00\u76ee\u3067\u308f\u304b\u308a\u307e\u3059\u3002\u6570\u5206\u3067\u3067\u304d\u305f\u4ed5\u4e8b\u3068\u3057\u3066\u306f\u3001\u304b\u306a\u308a\u826f\u3044\u3082\u306e\u3060\u3068\u8a00\u3048\u308b\u306e\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002Pro&nbsp;EZGC Chromatogram Modeler\u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u30e9\u30dc\u3067\u9577\u671f\u9593\u653e\u7f6e\u3055\u308c\u3066\u3044\u305f\u30ab\u30e9\u30e0\u3067\u3082\u3001\u5805\u7262\u3067\u8fc5\u901f\u306a\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u304c\u53ef\u80fd\u3067\u3057\u305f\u3002\u3055\u3089\u306b\u7d20\u6674\u3089\u3057\u3044\u306e\u306f\u3001\u3053\u306e\u958b\u767a\u304c\u3001\u308f\u305a\u304b\u6570\u5206\u3067\u3001GC\u88c5\u7f6e\u306b\u89e6\u308c\u305a\u3001\u6a19\u6e96\u8a66\u6599\u3092\u8abf\u88fd\u305b\u305a\u306b\u3067\u304d\u305f\u3053\u3068\u3067\u3059\u3002 \u3053\u3053\u307e\u3067\u306e\u52d5\u753b\u3092\u632f\u308a\u8fd4\u308a\u307e\u3059\u3002\u6700\u521d\u306b\u3001\u5316\u5408\u7269\u30ea\u30b9\u30c8\u306e\u5165\u529b\u65b9\u6cd5\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u30ab\u30e9\u30e0\u8cfc\u5165\u3082\u691c\u8a0e\u53ef\u80fd\u3067\u6700\u9069\u306a\u65b9\u6cd5\u3092\u6c42\u3081\u3066\u3044\u308b\u306a\u3089\u3001\u300cSearch by Name\uff08\u5316\u5408\u7269\u3067\u691c\u7d22\uff09\u300d\u306e\u4f7f\u7528\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002\u73fe\u5728\u30e9\u30dc\u306b\u3042\u308b\u30ab\u30e9\u30e0\u3067\u306e\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u8a08\u753b\u3057\u3066\u3044\u308b\u306a\u3089\u3001\u300cSearch by Phase\uff08\u56fa\u5b9a\u76f8\u3067\u691c\u7d22\uff09\u300d\u306e\u4f7f\u7528\u3092\u304a\u52e7\u3081\u3057\u307e\u3059\u3002 \u30a4\u30f3\u30bf\u30fc\u30d5\u30a7\u30fc\u30b9\u306b\u3064\u3044\u3066\u3082\u8a73\u3057\u304f\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u30e2\u30c7\u30eb\u8868\u793a\u9818\u57df\u306e\u60c5\u5831\u306f\u3001\u6642\u9593\u7bc0\u7d04\u306b\u975e\u5e38\u306b\u6709\u7528\u3067\u3059\u3002MS\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u52b9\u7387\u5316\u306b\u969b\u3057\u3001\u3053\u308c\u4ee5\u4e0a\u306e\u50cd\u304d\u3092\u3059\u308b\u3082\u306e\u306f\u4ed6\u306b\u306a\u3044\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002\u300cCondition\uff08\u5206\u6790\u6761\u4ef6\uff09\u300d\u30bf\u30d6\u306b\u95a2\u3059\u308b\u8aac\u660e\u306b\u306f\u591a\u304f\u306e\u6642\u9593\u3092\u4f7f\u3044\u307e\u3057\u305f\u3002\u91cd\u8981\u306a\u30dd\u30a4\u30f3\u30c8\u306f2\u3064\u3067\u3059\u3002\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u81ea\u52d5\u3067\u6700\u9069\u5316\u3059\u308b\u306e\u306f\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u307f\u3067\u3001\u4ed6\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u306b\u3064\u3044\u3066\u306f\u3001\u81ea\u7531\u306b\u5909\u66f4\u304c\u53ef\u80fd\u3067\u3059\u3002\u3053\u306e\u5909\u66f4\u306b\u6e96\u3058\u3066\u3001\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u304c\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u6700\u9069\u5316\u3057\u3066\u304f\u308c\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u3053\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u3067\u306f\u7dda\u901f\u5ea6\u3068\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u304c\u9023\u52d5\u3057\u3066\u3044\u306a\u3044\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u7dda\u901f\u5ea6\u304c\u5909\u308f\u308b\u306e\u306f\u3044\u3064\u3067\u3082\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3068\u3001\u6d41\u91cf\u3068\u304c\u5909\u66f4\u3055\u308c\u305f\u3068\u304d\u3067\u3059\u3002\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u3082\u305d\u308c\u306b\u6cbf\u3063\u3066\u6700\u9069\u5316\u3055\u308c\u307e\u3059\u3002\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306e\u8a2d\u5b9a\u5909\u66f4\u304a\u3088\u3073\u6d41\u91cf\u3084\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u306e\u8abf\u6574\u5f8c\u306b\u5206\u96e2\u304c\u8457\u3057\u304f\u4f4e\u4e0b\u3057\u305f\u5834\u5408\u3001\u63a8\u5968\u3055\u308c\u308b\u306e\u306f\u3001\u2460\u300cUndo\uff08\u5143\u306b\u623b\u3059\uff09\u300d\u3067\u76f4\u524d\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306b\u623b\u308a\u3001\u2461EZGC method translator\u3092\u4f7f\u7528\u3057\u3066\u3001\u65b0\u305f\u306a\u6761\u4ef6\u306b\u9069\u3057\u305f\u65b0\u3057\u3044\u30aa\u30fc\u30d6\u30f3\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u4f5c\u6210\u3057\u3001\u2462\u3053\u308c\u3092\u57fa\u306b\u3057\u305f\u6700\u9069\u5316\u3092\u884c\u3046\u3001\u3068\u3044\u3046\u624b\u9806\u306e\u5b9f\u884c\u3067\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u30d7\u30ed\u30b0\u30e9\u30e0\u3092\u65b0\u305f\u306b\u6700\u9069\u5316\u3059\u308b\u3053\u3068\u306f\u53ef\u80fd\u3067\u3059\u3002\u305f\u3060\u3057\u3001\u3053\u306e\u624b\u9806\u306e\u5b9f\u884c\u304c\u5fc5\u8981\u306a\u30b1\u30fc\u30b9\u306f\u7a00\u3067\u3059\u30029\u52729\u5206\u3001\u300cRefine\uff08\u8abf\u6574\uff09\u300d\u30dc\u30bf\u30f3\u3092\u4f7f\u3046\u3060\u3051\u3067\u5341\u5206\u826f\u597d\u306a\u5206\u96e2\u306f\u5f97\u3089\u308c\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u6d41\u91cf\u3084\u7a2e\u985e\u3001\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u3092\u5909\u66f4\u3057\u305f\u5834\u5408\u3067\u3042\u3063\u3066\u3082\u540c\u69d8\u3067\u3059\u3002 Pro&nbsp;EZGC Chromatogram Modeler\u306e\u3055\u3089\u306b\u8a73\u3057\u3044\u60c5\u5831\u306f\u3001\u52d5\u753b\u30b7\u30ea\u30fc\u30ba\u7b2c\u4e09\u5f3e\u3067\u3054\u7d39\u4ecb\u3057\u3066\u3044\u307e\u3059\u3002\u7b2c\u4e09\u5f3e\u3067\u306f\u5206\u96e2\u5ea6\u8981\u4ef6\u306b\u3064\u3044\u3066\u8a73\u3057\u304f\u89e3\u8aac\u3057\u3066\u3044\u307e\u3059\u3002MS\u5206\u6790\u306b\u969b\u3057\u3066\u3001\u8003\u616e\u3059\u3079\u304d\u70b9\u306b\u3064\u3044\u3066\u3082\u8a73\u8ff0\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u3001\u8a73\u7d30\u306a\u70b9\u306b\u307e\u3067\u8a00\u53ca\u3057\u305f\u30d8\u30eb\u30d7\u30d5\u30a1\u30a4\u30eb\u3082\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002\u3054\u4e0d\u660e\u70b9\u306b\u3064\u3044\u3066\u306f\u3001\u307e\u305a\u30d8\u30eb\u30d7\u30d5\u30a1\u30a4\u30eb\u3092\u3054\u53c2\u7167\u304f\u3060\u3055\u3044\u3002\u307e\u305f\u3001\u305c\u3072\u3054\u4e00\u8aad\u3044\u305f\u3060\u304d\u305f\u3044\u306e\u306f\u3001EZGC Suite\u30d6\u30ed\u30b0\u3067\u3059\u3002\u3053\u3053\u3067\u304a\u77e5\u3089\u305b\u3059\u308b\u6700\u65b0\u60c5\u5831\u306b\u306f\u3001\u65b0\u3057\u3044\u30e9\u30a4\u30d6\u30e9\u30ea\u3084\u30b7\u30e7\u30fc\u30c8\u30ab\u30c3\u30c8\u3001Pro&nbsp;EZGC Modeler\u306e\u9069\u7528\u4f8b\u306a\u3069\u304c\u3042\u308a\u307e\u3059\u3002\u3082\u3057\u30c7\u30fc\u30bf\u30d9\u30fc\u30b9\u306b\u76ee\u7684\u306e\u5316\u5408\u7269\u304c\u542b\u307e\u308c\u3066\u3044\u306a\u3051\u308c\u3070\u3001Restek\u306e\u6280\u8853\u30b5\u30fc\u30d3\u30b9\u3078\u304a\u6c17\u8efd\u306b\u3054\u76f8\u8ac7\u304f\u3060\u3055\u3044\u3002\u5206\u6790\u958b\u59cb\u6642\u304b\u3089\u3055\u307e\u3056\u307e\u306a\u30b5\u30dd\u30fc\u30c8\u3092\u3054\u63d0\u4f9b\u3044\u305f\u3057\u307e\u3059\u3002\u3054\u8996\u8074\u3042\u308a\u304c\u3068\u3046\u3054\u3056\u3044\u307e\u3057\u305f\u3002Restek\u304c\u76ee\u6307\u3057\u305f\u306e\u306f\u3001\u30e9\u30dc\u3067\u306e\u4f5c\u696d\u3092\u30b7\u30f3\u30d7\u30eb\u306b\u3057\u3066\u3001\u30b4\u30fc\u30eb\u306b\u4e00\u76f4\u7dda\u306b\u5411\u304b\u3048\u308b\u74b0\u5883\u3092\u63d0\u4f9b\u3059\u308b\u3053\u3068\u3067\u3059\u3002\u3053\u306e\u30bd\u30d5\u30c8\u30a6\u30a7\u30a2\u306f\u3001\u305d\u308c\u3092\u5b9f\u73fe\u3067\u304d\u308b\u3068\u601d\u3063\u3066\u3044\u307e\u3059\u3002\u3054\u8cea\u554f\u7b49\u3054\u3056\u3044\u307e\u3057\u305f\u3089\u3001\u3069\u3046\u305e\u304a\u6c17\u8efd\u306b\u304a\u554f\u3044\u5408\u308f\u305b\u304f\u3060\u3055\u3044\u3002<\/p>\n","protected":false},"author":11,"featured_media":41795,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[774],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340],"ppma_author":[414],"class_list":["post-71178","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-videos-ja","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":774,"label":"\u52d5\u753b"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-GNAV3635-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":774,"name":"\u52d5\u753b","slug":"videos-ja","term_group":0,"term_taxonomy_id":774,"taxonomy":"category","description":"","parent":0,"count":139,"filter":"raw","cat_ID":774,"category_count":139,"category_description":"","cat_name":"\u52d5\u753b","category_nicename":"videos-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"avatar_alt":"","avatar_decorative":"","author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71178","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71178"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71178\/revisions"}],"predecessor-version":[{"id":84520,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71178\/revisions\/84520"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/41795"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71178"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71178"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71178"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71178"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71178"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71178"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71178"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71178"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71178"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}