{"id":71332,"date":"2021-09-24T00:00:00","date_gmt":"2021-09-24T00:00:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71332"},"modified":"2026-04-27T19:22:13","modified_gmt":"2026-04-27T19:22:13","slug":"fast-8-minute-method-for-direct-injection-of-pfas-in-non-potable-water-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/evfa3693-ja\/fast-8-minute-method-for-direct-injection-of-pfas-in-non-potable-water-japan","title":{"rendered":"PFAS\u5206\u6790\u306e\u65b0\u6a19\u6e96\uff01Force C18\u30ab\u30e9\u30e0\u3067\u5b9f\u73fe\u3059\u308bPFBA\u5206\u96e2\u3068\u9ad8\u901f\u76f4\u63a5\u6ce8\u5165\u6cd5"},"content":{"rendered":"\n<ul class=\"wp-block-list\">\n<li>EPA Method 8327\u306b\u898f\u5b9a\u3055\u308c\u3066\u3044\u308bPFAS\u3092\u30e1\u30bd\u30c3\u30c9\u6761\u4ef6\u3088\u308a3\u500d\u901f\u304f\u5206\u6790<\/li>\n\n\n\n<li>\u76f4\u63a5\u6ce8\u5165\u6cd5\u306b\u3088\u308a\u3001\u6642\u9593\u306e\u304b\u304b\u308b\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u304c\u4e0d\u8981<\/li>\n\n\n\n<li>Force C18 FPP\u30ab\u30e9\u30e0\u306fPFBA\u306e\u4fdd\u6301\u3092\u9ad8\u3081\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u6539\u5584<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">\u98f2\u6599\u6c34\u4e2d\u306e\u30da\u30eb\u304a\u3088\u3073\u30dd\u30ea\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u5316\u5408\u7269\uff08PFAS\uff09\u306e\u5206\u6790\u3067\u306f\u3001\u901a\u5e38\u3001\u30b9\u30c1\u30ec\u30f3\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\u7cfb\u3084\u5f31\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\uff08WAX\uff09\u578b\u306e\u56fa\u76f8\u62bd\u51fa\uff08SPE\uff09\u3092\u7528\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u304c\u884c\u308f\u308c\u307e\u3059\u3002\u4e00\u65b9\u3001\u975e\u98f2\u6599\u6c34\u306b\u304a\u3051\u308bPFAS\u5206\u6790\u3067\u306f\u3001SPE\u3092\u7701\u7565\u3057\u305f\u76f4\u63a5\u6ce8\u5165\u6cd5\u304c\u4e00\u822c\u7684\u3067\u3059\u3002\u3053\u306e\u624b\u6cd5\u306e\u4ee3\u8868\u4f8b\u304cEPA Method 8327\u3067\u3042\u308a\u3001LC-MS\/MS\u3092\u7528\u3044\u3066\u5730\u4e0b\u6c34\u3001\u8868\u5c64\u6c34\u3001\u6392\u6c34\u3068\u3044\u3063\u305f\u975e\u98f2\u6599\u6c34\u4e2d\u306e24\u7a2e\u985e\u306ePFAS\u5316\u5408\u7269\u3092\u5b9a\u91cf\u3059\u308b\u305f\u3081\u306e\u3001\u30d0\u30ea\u30c7\u30fc\u30b7\u30e7\u30f3\u3055\u308c\u305f\u691c\u67fb\u65b9\u6cd5\u3067\u3059\u3002\u76f4\u63a5\u6ce8\u5165\u6cd5\u306f\u3001\u6642\u9593\u3068\u624b\u9593\u306e\u304b\u304b\u308bSPE\u51e6\u7406\u3092\u4e0d\u8981\u306b\u3059\u308b\u3053\u3068\u3067\u3001\u524d\u51e6\u7406\u306b\u304b\u304b\u308b\u30b3\u30b9\u30c8\u3084\u4f5c\u696d\u306e\u3070\u3089\u3064\u304d\u3092\u56de\u907f\u3067\u304d\u308b\u3068\u3044\u3046\u5927\u304d\u306a\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u306a\u304c\u3089\u3001\u3053\u306e\u65b9\u6cd5\u3067\u306f1\u56de\u3042\u305f\u308a\u306e\u5206\u6790\u6642\u9593\u304c21\u5206\u7a0b\u5ea6\u3068\u9577\u304f\u3001\u30b5\u30f3\u30d7\u30eb\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u306e\u5411\u4e0a\u306b\u306f\u9650\u754c\u304c\u3042\u308a\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u305d\u3053\u3067Restek\u306f\u3001EPA 8327\u306b\u898f\u5b9a\u3055\u308c\u3066\u3044\u308b24\u7a2e\u985e\u306e\u30bf\u30fc\u30b2\u30c3\u30c8PFAS\u306b\u52a0\u3048\u3001\u3055\u3089\u306b19\u7a2e\u985e\u306e\u4ee3\u66ffPFAS\u3082\u5bfe\u8c61\u3068\u3057\u3001\u308f\u305a\u304b8\u5206\u306e\u30b5\u30a4\u30af\u30eb\u30bf\u30a4\u30e0\u3067\u3053\u308c\u3089\u516843\u5316\u5408\u7269\u3092\u4e00\u6589\u5206\u6790\u3059\u308b\u9ad8\u901f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u6cd5\u3092\u958b\u767a\u3057\u307e\u3057\u305f\u3002\u672c\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u3059\u3079\u3066\u306e\u5206\u6790\u5bfe\u8c61\u6210\u5206\u306b\u5bfe\u3057\u3066\u5145\u5206\u306a\u691c\u51fa\u611f\u5ea6\uff08\u5e0c\u91c8\u524d\u6fc3\u5ea6\u306710 ppt\u30ec\u30d9\u30eb\uff09\u3092\u5b9f\u73fe\u3057\u3066\u304a\u308a\u3001\u30b9\u30eb\u30fc\u30d7\u30c3\u30c8\u3068\u611f\u5ea6\u306e\u4e21\u7acb\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4ee5\u4e0b\u306b\u793a\u3059\u5206\u6790\u6761\u4ef6\u3067\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><strong>\u30ab\u30e9\u30e0<\/strong><\/td><td>Force C18 (cat.# 9634352)<\/td><\/tr><tr><td>\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba<\/td><td>50 mm x 2.1 mm ID<\/td><\/tr><tr><td>\u7c92\u5b50\u5f84<\/td><td>3 \u00b5m<\/td><\/tr><tr><td>\u7d30\u5b54\u5f84<\/td><td>100 \u00c5<\/td><\/tr><tr><td>\u30ab\u30e9\u30e0\u6e29\u5ea6<\/td><td>40\u2103<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u6a19\u6e96\u8a66\u6599\uff0f\u30b5\u30f3\u30d7\u30eb<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>\u5e0c\u91c8\u6db2<\/td><td>50:50 \u6c34:\u30e1\u30bf\u30ce\u30fc\u30eb\u30010.1%\u9162\u9178<\/td><\/tr><tr><td>\u6fc3\u5ea6<\/td><td>80 ppt (\u30b5\u30ed\u30b2\u30fc\u30c8\u307e\u305f\u306f\u540c\u4f4d\u4f53\u6a19\u8b58PFAS\u306e\u5834\u5408\u306f40 ppt)<\/td><\/tr><tr><td>\u6ce8\u5165\u91cf<\/td><td>10 \u00b5L<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>\u79fb\u52d5\u76f8<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>A<\/td><td>\u6c34\u30015mM\u9162\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0<\/td><\/tr><tr><td>B<\/td><td>\u30e1\u30bf\u30ce\u30fc\u30eb<\/td><\/tr><tr><td>\u6d41\u901f<\/td><td>0.4 mL\/min.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8 &nbsp; &nbsp;80%A, 20%B\uff080.00\u5206\uff09\u21925%A, 95%B\uff086.00\u5206\uff09\u21925%A, 95%B\uff086.50\u5206\uff09\u219280%A, 20%B\uff086.51\u5206\uff09\u219280%A, 20%B\uff088.50\u5206\uff09<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><strong>\u691c\u51fa\u5668<\/strong><\/td><td>MS\/MS<\/td><\/tr><tr><td>\u30a4\u30aa\u30f3\u5316\u30e2\u30fc\u30c9<\/td><td>ESI negative<\/td><\/tr><tr><td>\u30e2\u30fc\u30c9 &nbsp; &nbsp;<\/td><td>MRM<\/td><\/tr><tr><td><strong>\u88c5\u7f6e<\/strong><\/td><td>UHPLC<\/td><\/tr><tr><td>\u5099\u8003<\/td><td>\u30a4\u30f3\u30b8\u30a7\u30af\u30bf\u30fc\u306e\u524d\u306bPFAS\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0(cat.# 27854)\u3092\u8a2d\u7f6e<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">\u7d50\u679c\u3068\u3057\u3066\u3001\u3059\u3079\u3066\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306f\u52b9\u7387\u3088\u304f\u5206\u96e2\u3055\u308c\u3001\u826f\u597d\u306a\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002FPP\u30ab\u30e9\u30e0\u306f\u3001\u8868\u9762\u7a4d\u304a\u3088\u3073\u30ab\u30fc\u30dc\u30f3\u30ed\u30fc\u30c9\u91cf\u304c\u9ad8\u304f\u3001\u5f93\u6765\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u308b\u8868\u9762\u591a\u5b54\u6027\u7c92\u5b50\uff08SPP\uff09\u30ab\u30e9\u30e0\u306b\u6bd4\u3079\u3066\u826f\u597d\u306a\u4fdd\u6301\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u7279\u306b\u3001PFBA\uff08\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u30d6\u30bf\u30f3\u9178\uff09\u306e\u3088\u3046\u306a\u6eb6\u51fa\u304c\u65e9\u3044\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u306f\u3001\u3053\u306e\u5206\u96e2\u80fd\u306e\u9ad8\u3055\u304c\u5927\u304d\u306a\u5229\u70b9\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">PFBA\u306f\u3001\u5206\u6790\u6761\u4ef6\u306b\u3088\u3063\u3066\u306f\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u6975\u3081\u3066\u60aa\u5316\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u30b5\u30f3\u30d7\u30eb\u5e0c\u91c8\u6db2\u3068\u521d\u671f\u306e\u79fb\u52d5\u76f8\u306e\u7d44\u6210\u304c\u4e00\u81f4\u3057\u306a\u3044\u3053\u3068\u3067\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u4e0d\u5b89\u5b9a\u8981\u7d20\u304c\u751f\u3058\u3001\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0\u3084\u30d4\u30fc\u30af\u5206\u88c2\u3068\u3044\u3063\u305f\u73fe\u8c61\u304c\u767a\u751f\u3057\u3084\u3059\u304f\u306a\u308b\u3001\u306a\u3069\u3067\u3059\u3002\u3053\u3046\u3057\u305f\u8ab2\u984c\u306b\u5bfe\u3057\u3066\u306f\u3001Force C18\u30ab\u30e9\u30e0\u306e\u63a1\u7528\u304c\u6709\u52b9\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308aPFBA\u306e\u4fdd\u6301\u6642\u9593\u3092\u9069\u5ea6\u306b\u5ef6\u9577\u3057\u3001\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306e\u5b89\u5b9a\u6027\u3068\u7cbe\u5ea6\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u5b9f\u969b\u306bPFAS\u306e\u76f4\u63a5\u6ce8\u5165\u6cd5\u3092\u63a1\u7528\u3057\u3066\u3044\u308b\u8907\u6570\u306e\u30e9\u30dc\u306b\u304a\u3044\u3066\u3082\u3001Force C18\u30ab\u30e9\u30e0\u306e\u4f7f\u7528\u306b\u3088\u308a\u3001EPA Method 8327\u306b\u57fa\u3065\u304f\u5316\u5408\u7269\u7fa4\u306b\u5bfe\u3057\u3066\u3001\u5f93\u6765\u306e\u304a\u3088\u305d3\u5206\u306e1\u3068\u3044\u3046\u77ed\u6642\u9593\u3067\u3001\u78ba\u304b\u306a\u5206\u96e2\u6027\u80fd\u304c\u5f97\u3089\u308c\u305f\u3068\u306e\u5831\u544a\u304c\u78ba\u8a8d\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001SPP\u30ab\u30e9\u30e0\u3067PFBA\u306e\u4fdd\u6301\u3084\u30d4\u30fc\u30af\u5f62\u72b6\u306b\u8ab2\u984c\u3092\u62b1\u3048\u3066\u3044\u305f\u30e9\u30dc\u3067\u3082\u3001\u3053\u3053\u3067\u8a2d\u5b9a\u3057\u305f\u6761\u4ef6\u4e0b\u3067Force C18\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u306b\u3088\u308a\u3001\u98db\u8e8d\u7684\u306a\u6539\u5584\u304c\u898b\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image regular-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0578.png\" alt=\"PFAS by Direct Injection on Force C18 (3 \u00b5m) (EPA Method 8327)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> LC_EV0578<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>9634352<\/li><li>27854<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>8327<\/li><li>PFAS<\/li><li>PFAS-library<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/lc_ev0578.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634352\">                                \u30ab\u30bf\u30ed\u30b0No. 9634352                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Force C18, 3 \u00b5m, 50 x 2.1 mm LC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/9634352\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">                                \u30ab\u30bf\u30ed\u30b0No. 27854                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">PFAS\u5206\u6790\uff5c\u30c7\u30a3\u30ec\u30a4\u30ab\u30e9\u30e0, 5 \u00b5m, 50 x 2.1 mm HPLC\u30ab\u30e9\u30e0<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/27854\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>PFAS\u306e\u5206\u6790\u901f\u5ea6\u3068\u7cbe\u5ea6\u3092\u4e21\u7acb\uff01Force C18\u30ab\u30e9\u30e0\u3068\u76f4\u63a5\u6ce8\u5165\u6cd5\u3092\u7528\u3044\u308b\u3053\u3068\u3067\u3001PFBA\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u6539\u5584\u304a\u3088\u3073EPA Method 8327\u7531\u6765\u5316\u5408\u7269\u306e\u9ad8\u901f\u5206\u96e2\u304c\u5b9f\u73fe\u3057\u307e\u3059\u3002\u56fa\u76f8\u62bd\u51fa\u3092\u7701\u7565\u3057\u3001\u30e9\u30dc\u306e\u52b9\u7387\u5411\u4e0a\u3068\u9ad8\u611f\u5ea6\u5206\u6790\u3092\u5b9f\u73fe\u3059\u308b\u30bd\u30ea\u30e5\u30fc\u30b7\u30e7\u30f3\u3067\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":71346,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[2760],"industries-application":[2288,2271],"post-badge":[],"resource-type":[2803],"product-library":[2571,2553],"resource-technique":[2365,2343],"ppma_author":[2814,2814],"class_list":["post-71332","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-environmental-ja","resource-type-featured-application","product-library-lc-columns-ja","product-library-liquid-chromatography-products-ja","resource-technique-ms-ms-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-type":[{"value":2803,"label":"Featured Application"}],"product-library":[{"value":2571,"label":"LC \u30ab\u30e9\u30e0"},{"value":2553,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVFA3693-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":2814,"user_id":0,"is_guest":1,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","author_category":"","first_name":"","last_name":"","user_url":"","job_title":"","description":""},{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71332","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71332"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71332\/revisions"}],"predecessor-version":[{"id":93028,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71332\/revisions\/93028"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/71346"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71332"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71332"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71332"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71332"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71332"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71332"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71332"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71332"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71332"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}