{"id":71496,"date":"2021-09-21T14:30:00","date_gmt":"2021-09-21T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71496"},"modified":"2026-04-27T19:15:54","modified_gmt":"2026-04-27T19:15:54","slug":"pfas-in-air-part-1-otm-45-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4767-ja\/pfas-in-air-part-1-otm-45-japan","title":{"rendered":"PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u7b2c1\u56de\uff1a \u6982\u8981"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6700\u7d42\u66f4\u65b0\u65e5\uff1a2025\u5e7410\u670810\u65e5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">PFAS\u6392\u30ac\u30b9\u3068\u7a7a\u6c17\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u306e\u91cd\u8981\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">PFAS\u306b\u95a2\u5fc3\u304c\u3042\u308b\u306a\u3089\u3001\u305d\u306e\u5b58\u5728\u7bc4\u56f2\u306e\u5e83\u3055\u3082\u3059\u3067\u306b\u3054\u5b58\u3058\u306e\u3053\u3068\u3067\u3057\u3087\u3046\u3002\u6c34\u4e2d\u306b\u591a\u304f\u898b\u3089\u308c\u308b\u3060\u3051\u3067\u306a\u304f\u3001\u79c1\u305f\u3061\u306e\u8863\u670d\u306b\u3082PFAS\u306f\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u3057\u3066\u4eca\u3084\u7a7a\u6c17\u30b5\u30f3\u30d7\u30eb\u3092\u6271\u3046\u30e9\u30dc\u306b\u304a\u3044\u3066\u3082\u3001PFAS\u306e\u5b58\u5728\u306f\u5927\u304d\u304f\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u5b9f\u9a13\u7528\u5668\u5177\u306b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u6c5a\u67d3\u304c\u3042\u308b\u3068\u3044\u3046\u3060\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u30022021\u5e741\u6708\u306bPFAS\u5316\u5408\u7269\u542b\u6709\u6392\u30ac\u30b9\u306e\u63a1\u53d6\u3068\u5206\u6790\u306b\u95a2\u3059\u308b\u30e1\u30bd\u30c3\u30c9\u300cOTM-45\u300d\u3092EPA\u304c\u516c\u8868\u3057\u305f\u3088\u3046\u306b\u3001\u6392\u30ac\u30b9\u306a\u3069\u306e\u7a7a\u6c17\u30b5\u30f3\u30d7\u30eb\u305d\u306e\u3082\u306e\u304cPFAS\u5206\u6790\u306e\u5bfe\u8c61\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">EPA\u304c\u767a\u8868\u3057\u305fOTM-45 \u3068\u306f\uff1f\u30c9\u30e9\u30d5\u30c8\u30e1\u30bd\u30c3\u30c9\u306e\u6982\u8981<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">OTM\uff08Other Test Methods\uff1a\u305d\u306e\u4ed6\u8a66\u9a13\u65b9\u6cd5\uff09\u306b\u3064\u3044\u3066\u307e\u305a\u8aac\u660e\u3057\u307e\u3057\u3087\u3046\u3002OTM\u3068\u306f\u9023\u90a6\u898f\u5247\u5236\u5b9a\u30d7\u30ed\u30bb\u30b9\u3092\u7d4c\u3066\u3044\u306a\u3044\u8a66\u9a13\u65b9\u6cd5\u306e\u3053\u3068\u3067\u3059\u3002EPA\u306e\u4ee5\u4e0b\u306e\u8868\u660e\u304b\u3089\u3082\u5206\u304b\u308b\u3088\u3046\u306b\u3001\u73fe\u72b6\u3067\u30c9\u30e9\u30d5\u30c8\u7248\u3067\u3042\u308bOTM-45\u3092\u6700\u7d42\u7248\u3068\u3057\u3066\u78ba\u5b9a\u3059\u308b\u305f\u3081\u306b\u3001\u56fa\u5b9a\u767a\u751f\u6e90\u304b\u3089\u306ePFAS\u5206\u6790\u3092\u884c\u3046\u30e9\u30dc\u306b\u304a\u3051\u308b\u8a66\u7528\u3068\u305d\u306e\u7d50\u679c\u306e\u30d5\u30a3\u30fc\u30c9\u30d0\u30c3\u30af\u306f\u5fc5\u9808\u3067\u3059\u3002<br><em>\u300cOTM-45\u306f\u30c9\u30e9\u30d5\u30c8\u30e1\u30bd\u30c3\u30c9\u3067\u3042\u308a\u3001\u73fe\u5834\u3084\u7814\u7a76\u6a5f\u95a2\u306a\u3069\u304b\u3089\u6e2c\u5b9a\u30c7\u30fc\u30bf\u3084\u30d5\u30a3\u30fc\u30c9\u30d0\u30c3\u30af\u304c\u3042\u308b\u3068\u66f4\u65b0\u3055\u308c\u308b\u3068\u3044\u3046\u67d4\u8edf\u6027\u3092\u6301\u3061\u307e\u3059\u3002\u3053\u308c\u306b\u4f34\u3044\u3001EPA\u306b\u3088\u308b\u90fd\u5ea6\u306e\u8a55\u4fa1\u304c\u5fc5\u8981\u3068\u306a\u308a\u307e\u3059\u304c\u3001\u30e1\u30bd\u30c3\u30c9\u306e\u4e00\u8cab\u6027\u3092\u4fdd\u3064\u3053\u3068\u3082\u55ab\u7dca\u306b\u5fc5\u8981\u3060\u3068\u8003\u3048\u3066\u3044\u307e\u3059\u3002\u305d\u3053\u3067\u3001\u4e00\u8cab\u6027\u78ba\u4fdd\u3092\u610f\u56f3\u3057\u3066\u3001EPA\u6392\u51fa\u6e2c\u5b9a\u30bb\u30f3\u30bf\u30fc\u306f\u300eOther Test Method\uff08OTM\uff09\u300f\u3092\u516c\u958b\u3057\u3001\u3053\u308c\u3092\u56fa\u5b9a\u767a\u751f\u6e90\u304b\u3089\u6392\u51fa\u3055\u308c\u308b\u30bf\u30fc\u30b2\u30c3\u30c8PFAS\u3092\u63a1\u53d6\u30fb\u5206\u6790\u3059\u308b\u6700\u65b0\u306e\u30d9\u30b9\u30c8\u30d7\u30e9\u30af\u30c6\u30a3\u30b9\u3068\u4f4d\u7f6e\u4ed8\u3051\u307e\u3057\u305f\u3002\u5927\u6c17\u6392\u51fa\u6e90\u304b\u3089\u306ePFAS\u306b\u95a2\u3059\u308b\u53c2\u7167\u6cd5\u7b56\u5b9a\u306e\u305f\u3081\u306b\u3001\u672c\u30e1\u30bd\u30c3\u30c9\u3092\u9069\u7528\u3057\u3066\u5f97\u3089\u308c\u305f\u30d5\u30a3\u30fc\u30c9\u30d0\u30c3\u30af\u3084\u30b3\u30e1\u30f3\u30c8\u3001\u8ffd\u52a0\u30c7\u30fc\u30bf\u3092\u5e45\u5e83\u304f\u52df\u96c6\u3057\u3066\u3044\u307e\u3059\u3002\u300d<\/em><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">OTM-45\u3067\u5f97\u3089\u308c\u308b4\u7a2e\u985e\u306e\u30b5\u30f3\u30d7\u30eb\u753b\u5206\u3068\u62bd\u51fa\u6cd5<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3067\u306f\u3001OTM-45\u306f\u5177\u4f53\u7684\u306b\u3069\u306e\u3088\u3046\u306a\u5185\u5bb9\u3067\u3057\u3087\u3046\u304b\u3002\u30b5\u30f3\u30d7\u30eb\u63a1\u53d6\u65b9\u6cd5\u306b\u3064\u3044\u3066\u306f\u3001SW-846 0010\u306b\u6163\u308c\u3066\u3044\u308b\u65b9\u306a\u3089\u3001\u8a66\u6599\u63a1\u53d6\u7cfb\uff08Sample Train\uff1a\u30b5\u30f3\u30d7\u30eb\u30c8\u30ec\u30a4\u30f3\uff09\u304c\u3088\u304f\u4f3c\u3066\u3044\u308b\u3053\u3068\u306b\u6c17\u3065\u304f\u306f\u305a\u3067\u3059\uff08Fig. 1\u53c2\u7167\uff09\u3002\u8a66\u6599\u63a1\u53d6\u7cfb\u306e\u5404\u30bb\u30af\u30b7\u30e7\u30f3\u3067\u306f\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u62bd\u51fa\u51e6\u7406\u304c\u884c\u308f\u308c\u3001\u6700\u7d42\u7684\u306b\u306f4\u3064\u306e\u30b5\u30f3\u30d7\u30eb\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30d6\u30ec\u30a4\u30af\u30b9\u30eb\u30fc\u78ba\u8a8d\u7528\u306eXAD-2\uff08\u30d4\u30f3\u30af\u306e\u30bb\u30af\u30b7\u30e7\u30f3\uff09\u306f\u5358\u72ec\u3067\u632f\u3068\u3046\u62bd\u51fa<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u524d\u534a\u30ea\u30f3\u30b9\u6db2\u3068\u30d5\u30a3\u30eb\u30bf\u30fc\uff08\u8d64\u3068\u9ec4\u306e\u30bb\u30af\u30b7\u30e7\u30f3\uff09\u306f\u7d44\u307f\u5408\u308f\u3055\u308c\u3066\u632f\u3068\u3046\u62bd\u51fa\uff08\u6eb6\u5a92\u3067\u6d17\u3044\u51fa\u3059\u7c21\u5358\u306a\u62bd\u51fa\u6cd5\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u5f8c\u534a\u30ea\u30f3\u30b9\u6db2\u3068\u6700\u521d\u306eXAD-2\u5438\u7740\u5264\uff08\u7dd1\u3068\u9752\u306e\u30bb\u30af\u30b7\u30e7\u30f3\uff09\u3082\u7d44\u307f\u5408\u308f\u3055\u308c\u3066\u632f\u3068\u3046\u62bd\u51fa<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u51dd\u7e2e\u6c34\u3001\u30a4\u30f3\u30d4\u30f3\u30b8\u30e3\u5185\u306e\u6c34\u3001\u30a4\u30f3\u30d4\u30f3\u30b8\u30e3\u30ea\u30f3\u30b9\u6db2\uff08\u7d2b\u3068\u30b0\u30ec\u30fc\u306e\u30bb\u30af\u30b7\u30e7\u30f3\uff09\u3082\u7d44\u307f\u5408\u308f\u3055\u308c\u3066\u3001<a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2019-12\/documents\/method-533-815b19020.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">EPA method 533<\/a>\u540c\u69d8\u306eWAX SPE\uff08\u5f31\u30a2\u30cb\u30aa\u30f3\u4ea4\u63db\u56fa\u76f8\u62bd\u51fa\uff09\u3067\u62bd\u51fa<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-1-otm-45-01.png\" alt=\"decorative\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig. 1 \u2013 OTM-45\u8a66\u6599\u63a1\u53d6\u7cfb<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">LC-MS\/MS\u5206\u6790\u3068\u540c\u4f4d\u4f53\u5e0c\u91c8\u6821\u6b63\u306e\u9069\u7528<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u62bd\u51fa\u5f8c\u3001\u5404\u30b5\u30f3\u30d7\u30eb\u306f\u3001EPA Method 533\u540c\u69d8\u306e\u540c\u4f4d\u4f53\u5e0c\u91c8\u306b\u3088\u308b\u6821\u6b63\u3092\u7528\u3044\u3066LC-MS\/MS\u3067\u5206\u6790\u3055\u308c\u307e\u3059\u304c\u3001\u5bfe\u8c61\u3068\u306a\u308b\u5316\u5408\u7269\u306e\u7a2e\u985e\u306fEPA Method 533\u3088\u308a\u3082\u306f\u308b\u304b\u306b\u591a\u304f\u306a\u308a\u307e\u3059\u3002\u5b9f\u5728\u78ba\u8a8d\u3055\u308c\u305fPFAS\u5316\u5408\u7269\u306b\u95a2\u3059\u308b\u30c7\u30fc\u30bf\u304c\u9650\u5b9a\u7684\u306a\u305f\u3081\u3001EPA\u306f\u53ef\u80fd\u306a\u9650\u308a\u5e83\u7bc4\u306aPFAS\u3092\u30ab\u30d0\u30fc\u3059\u308b\u3068\u3044\u3046\u30a2\u30d7\u30ed\u30fc\u30c1\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002\u7d50\u679c\u3068\u3057\u3066\u3001\u5bfe\u8c61\u5316\u5408\u7269\u3084\u62bd\u51fa\u524d\u5f8c\u306b\u7528\u3044\u308b\u5185\u90e8\u6a19\u6e96\u7269\u8cea\uff08\u5b89\u5b9a\u540c\u4f4d\u4f53\u306e\u30a2\u30ca\u30ed\u30b0\uff09\u306e\u6570\u306f\u591a\u304f\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001OTM-45\u306b\u57fa\u3065\u3044\u305f\u30b5\u30f3\u30d7\u30eb\u5206\u6790\u306f\u3001\u5358\u306b\u65e2\u5b58\u306eEPA Method 533\u306b\u57fa\u3065\u304fLC-MS\/MS\u5206\u6790\u3092\u5b9f\u884c\u3059\u308b\u3060\u3051\u3067\u3088\u3044\u3001\u3068\u3044\u3046\u3053\u3068\u306b\u306f\u306a\u3089\u306a\u3044\u306e\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30d6\u30ed\u30b0\u306f\u300c\u7b2c1\u56de\u300d\u3067\u3059\u3002\u3054\u60f3\u50cf\u306e\u901a\u308a\u3001OTM-45\u306b\u3064\u3044\u3066\u306fLC-MS\/MS\u5206\u6790\u3001\u6821\u6b63\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3001\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3068\u6e05\u6d44\u5ea6\u306e\u554f\u984c\u3068\u3044\u3063\u305f\u5185\u5bb9\u3092\u51685\u56de\u306e\u30d6\u30ed\u30b0\u30b7\u30ea\u30fc\u30ba\u3067\u8a73\u3057\u304f\u89e3\u8aac\u3057\u3066\u3044\u304f\u4e88\u5b9a\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4768-ja\/pfas-in-air-part-2-otm-45-japan\">\uff1c\u7b2c2\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306b\u57fa\u3065\u3044\u305f\u6700\u9069\u5316<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4769-ja\/pfas-in-air-part-3-otm-45-calibrations-japan\">\uff1c\u7b2c3\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u6821\u6b63<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/press-releases-news-ja\/gnbl4770-ja\/pfas-in-air-part-4-otm-45-resin-cleaning-japan\">\uff1c\u7b2c4\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30ec\u30b8\u30f3\u6d17\u6d44<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4771-ja\/pfas-in-air-part-5-resin-extraction-japan\">\uff1c\u7b2c5\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30ec\u30b8\u30f3\u62bd\u51fa<\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u8003\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>EPA OTM-45 (<a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2021-01\/documents\/otm_45_semivolatile_pfas_1-13-21.pdf<\/a>)<\/li>\n\n\n\n<li>EPA Method 533 (<a href=\"https:\/\/www.epa.gov\/sites\/default\/files\/2019-12\/documents\/method-533-815b19020.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.epa.gov\/sites\/default\/files\/2019-12\/documents\/method-533-815b19020.pdf<\/a>)<\/li>\n<\/ol>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>EPA\u304c\u767a\u8868\u3057\u305fPFAS\u6392\u30ac\u30b9\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3068\u5206\u6790\u306e\u30e1\u30bd\u30c3\u30c9OTM-45\u3092\u89e3\u8aac\u3002\u56fa\u5b9a\u767a\u751f\u6e90PFAS\u691c\u67fb\u306b\u5fc5\u8981\u306a\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u624b\u9806\u3084LC-MS\/MS\u5206\u6790\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u521d\u5fc3\u8005\u306b\u3082\u308f\u304b\u308a\u3084\u3059\u304f\u7d39\u4ecb\u3057\u307e\u3059\u3002\u7b2c1\u56de\u3067\u306fOTM\u201145 \u306e\u8a66\u6599\u63a1\u53d6\u7cfb\u3084\u5206\u6790\u6982\u8981\u3092\u7d39\u4ecb\u3057\u3001\u7a7a\u6c17\u30b5\u30f3\u30d7\u30eb\u4e2d\u306ePFAS\u6e2c\u5b9a\u306e\u6700\u524d\u7dda\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":27,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2760],"industries-application":[2288,2272,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2365,2339,2343],"ppma_author":[447],"class_list":["post-71496","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-air-monitoring-ja","industries-application-environmental-ja","resource-technique-ms-ms-ja","resource-technique-air-sampling-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2272,"label":"\u5927\u6c17 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2339,"label":"\u30a8\u30a2\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jason Hoisington","author_link":"https:\/\/discover.restek.com\/ja\/author\/jason-hoisington\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":447,"user_id":27,"is_guest":0,"slug":"jason-hoisington","display_name":"Jason Hoisington","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg"},"author_category":"1","first_name":"Jason","last_name":"Hoisington","user_url":"https:\/\/www.linkedin.com\/in\/jason-hoisington-73067653\/","job_title":"Principal Scientist, Sample Preparation","description":"Jason Hoisington received his bachelor\u2019s degree in general science with a focus on chemistry from the University of Alaska, Fairbanks. He worked for SGS Environmental for seven years in environmental soil and water testing, developing methods for the analysis of volatiles and semivolatile organics to include pesticides and polychlorinated biphenyls (PCBs). In 2012, Jason moved on to lab and application support for Dow Chemical Company, providing advanced analytical troubleshooting and method development. In 2019, Jason joined Restek and has focused on air applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71496","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71496"}],"version-history":[{"count":5,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71496\/revisions"}],"predecessor-version":[{"id":93962,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71496\/revisions\/93962"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71496"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71496"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71496"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71496"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71496"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71496"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71496"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71496"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71496"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}