{"id":71501,"date":"2021-12-01T13:30:00","date_gmt":"2021-12-01T13:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71501"},"modified":"2026-04-27T19:23:08","modified_gmt":"2026-04-27T19:23:08","slug":"pfas-in-air-part-2-otm-45-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4768-ja\/pfas-in-air-part-2-otm-45-japan","title":{"rendered":"PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u7b2c2\u56de\uff1a \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306b\u57fa\u3065\u3044\u305f\u6700\u9069\u5316"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6700\u7d42\u66f4\u65b0\u65e5\uff1a2025\u5e7410\u670810\u65e5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">OTM-45\u306b\u304a\u3051\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306e\u91cd\u8981\u6027\u3068\u306f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u300c\u7b2c1\u56de\u300d\u3067\u306f\u3001OTM-45\uff08EPA\u63d0\u6848\u306e\u5927\u6c17\u4e2dPFAS\u5206\u6790\u6cd5\uff09\u306b\u95a2\u3059\u308b\u5c0e\u5165\u30ac\u30a4\u30c9\u3067\u3057\u305f\u3002\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306b\u304a\u3051\u308b\u4e2d\u5fc3\u7684\u306a\u6280\u8853\u8981\u7d20\u306f\u3001\u8a66\u6599\u63a1\u53d6\u3068\u62bd\u51fa\u306b\u3042\u308b\u3053\u3068\u306f\u3054\u7406\u89e3\u3044\u305f\u3060\u3051\u305f\u304b\u3068\u601d\u3044\u307e\u3059\u3002\u305d\u3053\u3067\u300c\u7b2c2\u56de\u300d\u3067\u306f\u3001\u524d\u51e6\u7406\u5de5\u7a0b\u306e\u59a5\u5f53\u6027\u3084\u8a66\u6599\u63a1\u53d6\u7cfb\u306e\u6709\u52b9\u6027\u3092\u9069\u5207\u306b\u8a55\u4fa1\u3059\u308b\u305f\u3081\u306b\u3082\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306b\u6ce8\u76ee\u3059\u3079\u304d\u3067\u3042\u308b\u3001\u3068\u3044\u3046\u70b9\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3066\u3044\u304d\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">OTM-45\u306eHPLC\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u3068\u305d\u306e\u80cc\u666f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">OTM-45\u306f\u3001LC-MS\/MS\u30e1\u30bd\u30c3\u30c9\u306b\u95a2\u3057\u3066\u5177\u4f53\u7684\u6307\u91dd\u3092\u307b\u3068\u3093\u3069\u793a\u3057\u3066\u3044\u307e\u305b\u3093\u3002EPA 533\uff08\u98f2\u6599\u6c34\u4e2d\u306ePFAS\u5206\u6790\u30e1\u30bd\u30c3\u30c9\uff09\u3092\u30d9\u30fc\u30b9\u306b\u3057\u3066\u304a\u308a\u3001\u4f7f\u7528\u3059\u308b\u6eb6\u5a92\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u3082EPA533\u3068\u5168\u304f\u540c\u3058\u3067\u3001Table 1\u306b\u8a18\u8f09\u3057\u3066\u3044\u308b\u901a\u308a\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u305d\u308c\u4ee5\u5916\u306e\u90e8\u5206\u306b\u3064\u3044\u3066\u306f\u5206\u96e2\u5ea6\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u6700\u9069\u5316\u3059\u308b\u3088\u3046\u306b\u3001\u3068\u3044\u3046\u6307\u793a\u306e\u307f\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th>\u6642\u9593 (min)<\/th><th>20\u202fmM \u9162\u9178\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u6fc3\u5ea6<\/th><th>\u30e1\u30bf\u30ce\u30fc\u30eb\u6fc3\u5ea6<\/th><\/tr><\/thead><tbody><tr><td>\u958b\u59cb\u6642<\/td><td>95.0<\/td><td>5.0<\/td><\/tr><tr><td>0.5<\/td><td>95.0<\/td><td>5.0<\/td><\/tr><tr><td>3.0<\/td><td>60.0<\/td><td>40.0<\/td><\/tr><tr><td>16.0<\/td><td>20.0<\/td><td>80.0<\/td><\/tr><tr><td>18.0<\/td><td>20.0<\/td><td>80.0<\/td><\/tr><tr><td>20.0<\/td><td>5.0<\/td><td>95.0<\/td><\/tr><tr><td>22.0<\/td><td>5.0<\/td><td>95.0<\/td><\/tr><tr><td>25.0<\/td><td>95.0<\/td><td>5.0<\/td><\/tr><tr><td>35.0<\/td><td>95.0<\/td><td>5.0<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Table 1 \u2013 OTM-45 HPLC\u30b0\u30e9\u30b8\u30a8\u30f3\u30c8\u6761\u4ef6\u4f8b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u300c\u6642\u77ed\u304b\u3064\u7c21\u5358\u300d\u304c\u512a\u5148\u3055\u308c\u308b\u73fe\u4ee3\u306b\u304a\u3044\u3066\u300135\u5206\u306e\u30e9\u30f3\u30bf\u30a4\u30e0\u306f\u9577\u3059\u304e\u308b\u3068\u611f\u3058\u308b\u65b9\u304c\u591a\u3044\u3067\u3057\u3087\u3046\u3002\u6642\u9593\u77ed\u7e2e\u306f\u3001Fig. 1\u306b\u793a\u3057\u305f\u3088\u3046\u306b\u7c21\u5358\u306b\u884c\u3048\u307e\u3059\u3002\u4eca\u56de\u4f7f\u7528\u3057\u305f\u5206\u6790\u6761\u4ef6\u306fSW-846 8327 Method\u306e\u3082\u306e\u3068\u975e\u5e38\u306b\u8fd1\u3044\u8a2d\u5b9a\u3067\u3059\u3002\u7570\u306a\u308b\u70b9\u306f\u3001\u3044\u304f\u3064\u304b\u306e\u5f8c\u671f\u306b\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u3092\u6b63\u78ba\u306b\u691c\u51fa\u3059\u308b\u305f\u3081\u306b\u3001\u79fb\u52d5\u76f8B\u306e95\uff05\u6761\u4ef6\u3092\u308f\u305a\u304b\u306b\u5ef6\u9577\u3057\u3066\u3044\u308b\u70b9\u306e\u307f\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-2-otm-45-chromatography-01.png\" alt=\"blog-OTM-45-blog-2-chromatography-01.png\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig. 1 \u2013 HPLC-MS\/MS\u6761\u4ef6<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3067\u898b\u308bPFAS\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593\u3068\u30d4\u30fc\u30af\u5f62\u72b6<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Fig. 2\u306b\u306f\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3068\u4fdd\u6301\u6642\u9593\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002Force C18\u30ab\u30e9\u30e0\u3092\u4f7f\u3048\u3070\u3001\u65e9\u671f\u306b\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269 PFBA\u3067\u3082\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u5f97\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-2-otm-45-chromatography-02.png\" alt=\"graphical user interface\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig. 2 \u2013 OTM-45\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3068\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6ce8\u5165\u6eb6\u5a92\u3068\u6ce8\u5165\u91cf\u304cPFBA\u30d4\u30fc\u30af\u306b\u4e0e\u3048\u308b\u5f71\u97ff<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u305f\u3060\u3057\u3001PFBA\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306f\u5d29\u308c\u3084\u3059\u3044\u6027\u8cea\u3092\u6301\u3064\u305f\u3081\u3001\u6eb6\u5a92\u306e\u9078\u629e\u3068\u6ce8\u5165\u91cf\u306b\u6ce8\u610f\u304c\u5fc5\u8981\u3067\u3059\u3002\u6eb6\u5a92\u306b\u3064\u3044\u3066OTM-45\u306eSection 10.3\u3067\u306f\u3001\u65e9\u671f\u306b\u6eb6\u51fa\u3059\u308b\u6210\u5206\u3092\u7cbe\u5ea6\u3088\u304f\u5206\u96e2\u3059\u308b\u3053\u3068\u3092\u76ee\u7684\u3068\u3057\u305f\u3001\u62bd\u51fa\u6db2\u306e\u6c34\u6027\u6210\u5206\u5897\u91cf\u3092\u8a31\u53ef\u3057\u3066\u3044\u307e\u305b\u3093\u3002\u307e\u305f\u3001Section 11.2.2\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u3092\u3001DI\u6c34\u307e\u305f\u306f5\uff05\u30a2\u30f3\u30e2\u30cb\u30a2\u6c34\u9178\u5316\u7269\u3092\u30e1\u30bf\u30ce\u30fc\u30eb\u306b\u6eb6\u304b\u3057\u305f\u6eb6\u6db2\u306e\u3044\u305a\u308c\u304b\u3092\u4f7f\u7528\u3057\u3066\u6fc3\u7e2e\u3057\u305f\u5f8c\u30012 mL\u307e\u3067\u8abf\u6574\u3059\u308b\u3053\u3068\u3092\u6307\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u6ce8\u5165\u91cf\u306b\u3064\u3044\u3066\u306f\u3001Fig. 3\u306b\u793a\u3057\u305f\u3088\u3046\u306b\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u6db2\u306e\u307f\u306e\u6ce8\u5165\u3067\u306f\u30d4\u30fc\u30af\u306e\u5206\u88c2\u3092\u5f15\u304d\u8d77\u3053\u3059\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u4ee3\u308f\u308a\u306bEPA 533\u306e\u6700\u7d42\u7684\u306a\u6eb6\u5a92\u7d44\u6210\u3068\u540c\u3058\u3001\u30e1\u30bf\u30ce\u30fc\u30eb:\u6c34\uff0880:20\uff09\u306e\u6df7\u5408\u6eb6\u5a92\u3092\u4f7f\u7528\u3059\u308b\u3068\u30015 \u00b5L\u3067\u306f\u30d4\u30fc\u30af\u306e\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0\u304c\u82e5\u5e72\u751f\u3058\u305f\u305f\u3081\u30013 \u00b5L\u306b\u4e0b\u3052\u305f\u3068\u3053\u308d\u5bfe\u79f0\u7684\u306a\u304d\u308c\u3044\u306a\u30d4\u30fc\u30af\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-2-otm-45-chromatography-03.png\" alt=\"shape, rectangle\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig. 3 \u2013 5 \u00b5L 100 % MeOH\uff08\u5de6\uff09\u30015 \u00b5L 80:20 MeOH:\u6c34\uff08\u4e2d\u592e\uff09\u30013 \u00b5L 80:20 MeOH:\u6c34\uff08\u53f3\uff09\u3067\u306ePFBA\u306e\u30d4\u30fc\u30af\u5f62\u72b6<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">HPLC\u30b7\u30b9\u30c6\u30e0\u5727\u529b\u3078\u306e\u5bfe\u5fdc\uff1a\u30ab\u30e9\u30e0\u7c92\u5f84\u306e\u9055\u3044\u3068\u305d\u306e\u5f71\u97ff<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u306e\u6b20\u70b9\u306f\u3001\u5fc5\u8981\u3068\u3059\u308b\u5727\u529b\u304c\u975e\u5e38\u306b\u9ad8\u3044\u3053\u3068\u3067\u3059\u30021.8 \u00b5m Force\u30ab\u30e9\u30e0\u306e\u30d4\u30fc\u30af\u5727\u306f\u7d047000 psi\u306b\u9054\u3057\u3001\u3053\u308c\u306f\u4e00\u90e8\u306eHPLC\u30b7\u30b9\u30c6\u30e0\u306b\u3068\u3063\u3066\u306f\u9ad8\u3059\u304e\u307e\u3059\u3002\u3053\u308c\u306b\u3064\u3044\u3066\u306f\u30013.0 \u00b5m Force\u306b\u5207\u308a\u66ff\u3048\u3001\u5727\u529b\u3092\u7d043000 psi\u306b\u4e0b\u3052\u308b\u3068\u3044\u3046\u5bfe\u7b56\u3092\u8b1b\u3058\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\uff08Fig. 4\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-2-otm-45-chromatography-04.png\" alt=\"chart\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig. 4 \u2013 3.0 \u00b5m Force \u30ab\u30e9\u30e0\uff08\u4e0a\u3001\u6700\u9ad8\u5727\u529b \uff5e3000 psi\uff09\u3068 1.8 \u00b5m Force \u30ab\u30e9\u30e0\uff08\u4e0b\u3001\u6700\u9ad8\u5727\u529b \uff5e6000 psi\uff09\u306e\u5727\u529b<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ab\u30e9\u30e0\u7c92\u5f84\u30921.8 \u00b5m\u304b\u30893.0 \u00b5m\u3078\u5909\u66f4\u3057\u3066\u3082\u3001\u4fdd\u6301\u6642\u9593\u306b\u307b\u3068\u3093\u3069\u5f71\u97ff\u306f\u3042\u308a\u307e\u305b\u3093\u3002Fig. 5\u306b\u3088\u308b\u3068\u3001\u65e9\u671f\u306b\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593\u306f\u7d046%\u307b\u3069\u9577\u304f\u306a\u308a\u307e\u3059\u304c\u3001\u3053\u306e\u5f71\u97ff\u306f\u305d\u306e\u3046\u3061\u306e\u3044\u304f\u3064\u304b\u306b\u9650\u3089\u308c\u3001\u305d\u308c\u4ee5\u5916\u306e\u5316\u5408\u7269\u306e\u4fdd\u6301\u6642\u9593\u306f\u7c92\u5f84\u304c\u5909\u308f\u3063\u3066\u3082\u307b\u3068\u3093\u3069\u5909\u5316\u3057\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-2-otm-45-chromatography-05.png\" alt=\"chart, bar chart\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig. 5 \u2013 3.0 \u00b5m:1.8 \u00b5m Force \u30ab\u30e9\u30e0\u306e\u4fdd\u6301\u6642\u9593\u6bd4<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u7c92\u5f84\u5909\u66f4\u306b\u3088\u308b\u611f\u5ea6\u5909\u5316\u3068\u5206\u6790\u3078\u306e\u5f71\u97ff<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7c92\u5b50\u5f84\u3092\u5927\u304d\u304f\u3059\u308b\u3053\u3068\u306b\u3088\u3063\u3066\u3001\u5e73\u5747\u30d4\u30fc\u30af\u9ad8\u3055\u306f\u308f\u305a\u304b\u306b\u4f4e\u4e0b\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5206\u6790\u76ee\u7684\u3084\u30c7\u30fc\u30bf\u89e3\u6790\u6761\u4ef6\u306b\u3088\u3063\u3066\u306f\u5f71\u97ff\u304c\u3042\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002Fig. 6\u306b\u306f20 ppb\u6a19\u6e96\u8a66\u6599\u306b\u304a\u3051\u308b\u76f8\u5bfe\u30d4\u30fc\u30af\u9ad8\u3055\u306e\u6bd4\u8f03\u304c\u793a\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u4e00\u90e8\u306e\u5316\u5408\u7269\u306f3 \u00b5m\u30ab\u30e9\u30e0\u306e\u65b9\u304c\u30d4\u30fc\u30af\u306f\u9ad8\u304f\u306a\u308a\u307e\u3059\u304c\u3001\u5927\u534a\u306e\u5316\u5408\u7269\u306f1.8 \u00b5m\u30ab\u30e9\u30e0\u3067\u3088\u308a\u9ad8\u3044\u30d4\u30fc\u30af\u9ad8\u3055\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u305f\u304c\u3063\u30661.8 \u00b5m\u30ab\u30e9\u30e0\u3067\u306fS\/N\u6bd4\u304c\u5411\u4e0a\u3057\u3001\u5fae\u91cf\u5206\u6790\u306b\u304a\u3044\u3066\u3082\u7cbe\u5ea6\u306e\u9ad8\u3044\u5b9a\u91cf\u304c\u5b9f\u73fe\u3055\u308c\u307e\u3059\u3002\u9ad8\u5727\u5bfe\u5fdc\u53ef\u80fd\u306a\u30b7\u30b9\u30c6\u30e0\u3067\u3042\u308c\u3070\u30011.8 \u00b5m\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u691c\u51fa\u611f\u5ea6\u306e\u5411\u4e0a\u304c\u898b\u8fbc\u3081\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-2-otm-45-chromatography-06.png\" alt=\"chart, bar chart\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Fig. 6 \u2013 3.0\u00b5m:1.8\u00b5m Force \u30ab\u30e9\u30e0\u306e\u30d4\u30fc\u30af\u9ad8\u3055\u6bd4<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306e\u30d6\u30ed\u30b0\u30b7\u30ea\u30fc\u30ba\u3067\u306fOTM-45\u306b\u30d5\u30a9\u30fc\u30ab\u30b9\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u3053\u3067\u793a\u3057\u305f\u30e1\u30bd\u30c3\u30c9\u306f\u3001\u5bfe\u8c61\u5316\u5408\u7269\u304c\u591a\u3044\u4ed6\u306ePFAS\u30e1\u30bd\u30c3\u30c9\uff08\u4f8b\u3048\u3070\u30c9\u30e9\u30d5\u30c8\u7248Method 1633&nbsp;\u6ce8\uff1aMethod 1633\u306f2024\u5e74\u306b\u6700\u7d42\u7248\u304c\u516c\u958b\u6e08\u307f\u3067\u3059\uff09\u306b\u9069\u7528\u3067\u304d\u308b\u306f\u305a\u3067\u3059\u3002\u3053\u306e\u30b7\u30ea\u30fc\u30ba\u306e\u7b2c3\u56de\u3067\u306f\u3001\u88c5\u7f6e\u5206\u6790\u306e\u3082\u3046 1 \u3064\u306e\u91cd\u8981\u306a\u90e8\u5206\u3067\u3042\u308b\u6821\u6b63\u3092\u53d6\u308a\u4e0a\u3052\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4767-ja\/pfas-in-air-part-1-otm-45-japan\">\uff1c\u7b2c1\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u6982\u8981<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4769-ja\/pfas-in-air-part-3-otm-45-calibrations-japan\">\uff1c\u7b2c3\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u6821\u6b63<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/press-releases-news-ja\/gnbl4770-ja\/pfas-in-air-part-4-otm-45-resin-cleaning-japan\">\uff1c\u7b2c4\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30ec\u30b8\u30f3\u6d17\u6d44<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4771-ja\/pfas-in-air-part-5-resin-extraction-japan\">\uff1c\u7b2c5\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30ec\u30b8\u30f3\u62bd\u51fa<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>EPA\u304c\u767a\u8868\u3057\u305fPFAS\u6392\u30ac\u30b9\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3068\u5206\u6790\u306e\u30e1\u30bd\u30c3\u30c9OTM-45\u3092\u89e3\u8aac\u3002\u56fa\u5b9a\u767a\u751f\u6e90PFAS\u691c\u67fb\u306b\u5fc5\u8981\u306a\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u624b\u9806\u3084LC-MS\/MS\u5206\u6790\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u521d\u5fc3\u8005\u306b\u3082\u308f\u304b\u308a\u3084\u3059\u304f\u7d39\u4ecb\u3057\u307e\u3059\u3002\u7b2c2\u56de\u3067\u306f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u3092\u8a73\u3057\u304f\u898b\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n","protected":false},"author":27,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2760],"industries-application":[2288,2272,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2365,2339,2343],"ppma_author":[447],"class_list":["post-71501","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-air-monitoring-ja","industries-application-environmental-ja","resource-technique-ms-ms-ja","resource-technique-air-sampling-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2272,"label":"\u5927\u6c17 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2339,"label":"\u30a8\u30a2\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jason Hoisington","author_link":"https:\/\/discover.restek.com\/ja\/author\/jason-hoisington\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":447,"user_id":27,"is_guest":0,"slug":"jason-hoisington","display_name":"Jason Hoisington","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg"},"author_category":"1","first_name":"Jason","last_name":"Hoisington","user_url":"https:\/\/www.linkedin.com\/in\/jason-hoisington-73067653\/","job_title":"Principal Scientist, Sample Preparation","description":"Jason Hoisington received his bachelor\u2019s degree in general science with a focus on chemistry from the University of Alaska, Fairbanks. He worked for SGS Environmental for seven years in environmental soil and water testing, developing methods for the analysis of volatiles and semivolatile organics to include pesticides and polychlorinated biphenyls (PCBs). In 2012, Jason moved on to lab and application support for Dow Chemical Company, providing advanced analytical troubleshooting and method development. In 2019, Jason joined Restek and has focused on air applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71501","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71501"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71501\/revisions"}],"predecessor-version":[{"id":93963,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71501\/revisions\/93963"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71501"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71501"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71501"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71501"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71501"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71501"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71501"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71501"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71501"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}