{"id":71505,"date":"2022-03-22T14:30:00","date_gmt":"2022-03-22T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71505"},"modified":"2026-04-15T19:52:32","modified_gmt":"2026-04-15T19:52:32","slug":"pfas-in-air-part-3-otm-45-calibrations-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4769-ja\/pfas-in-air-part-3-otm-45-calibrations-japan","title":{"rendered":"PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45 \u00a0\u7b2c3\u56de\uff1a \u6821\u6b63"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6700\u7d42\u66f4\u65b0\u65e5\uff1a2025\u5e7410\u670810\u65e5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">OTM-45\u306b\u304a\u3051\u308b\u88c5\u7f6e\u6821\u6b63\u306e\u91cd\u8981\u6027\u3068\u306f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30d6\u30ed\u30b0\u30b7\u30ea\u30fc\u30ba\u7b2c1\u56de\u3001\u7b2c2\u56de\u306f\u304a\u8aad\u307f\u3044\u305f\u3060\u3051\u307e\u3057\u305f\u3067\u3057\u3087\u3046\u304b\uff1f\u7b2c1\u56de\u3067\u306f\u30c9\u30e9\u30d5\u30c8\u7248OTM-45 Method\u306e\u6982\u8981\u3001\u7b2c2\u56de\u3067\u306fLC\u30e1\u30bd\u30c3\u30c9\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u4eca\u56de\u306e\u30d6\u30ed\u30b0\u3067\u306f\u3001OTM-45\u7528\u306e\u88c5\u7f6e\u306e\u6821\u6b63\u65b9\u6cd5\u306b\u3064\u3044\u3066\u89e3\u8aac\u3057\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u306a\u305c\u6c7a\u5b9a\u4fc2\u6570\uff08r\u00b2\uff09\u3084 %RSD \u304c\u4f7f\u308f\u308c\u306a\u304f\u306a\u3063\u305f\u306e\u304b<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">TO-15A\u306e\u6821\u6b63\u306b\u95a2\u3059\u308b\u30d6\u30ed\u30b0\u306b\u3082\u66f8\u304d\u307e\u3057\u305f\u304c\u3001\u691c\u91cf\u7dda\u306f\u79c1\u306b\u3068\u3063\u3066\u975e\u5e38\u306b\u601d\u3044\u5165\u308c\u306e\u3042\u308b\u30c6\u30fc\u30de\u3067\u3059\u3002\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3084\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u3078\u306e\u95a2\u5fc3\u306e\u9ad8\u3055\u3068\u6bd4\u3079\u3066\u3001\u691c\u91cf\u7dda\u3078\u306e\u6ce8\u76ee\u5ea6\u306f\u305d\u308c\u307b\u3069\u9ad8\u304f\u306a\u304f\u3001\u5f62\u5f0f\u7684\u306a\u4f5c\u696d\u3068\u3057\u3066\u51e6\u7406\u3055\u308c\u3066\u3057\u307e\u3063\u3066\u3044\u308b\u611f\u304c\u3042\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u898f\u5b9a\u5024\u3084\u6761\u4ef6\u3068\u3044\u3063\u305f\u30e1\u30bd\u30c3\u30c9\u8981\u4ef6\u304c\u30af\u30ea\u30a2\u3055\u308c\u3066\u3044\u308b\u304b\u3092\u30c1\u30a7\u30c3\u30af\u3059\u308b\u3053\u3068\u306b\u91cd\u70b9\u304c\u7f6e\u304b\u308c\u3001\u6821\u6b63\u306e\u8a2d\u8a08\u304c\u5206\u6790\u7d50\u679c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u304b\u306b\u3064\u3044\u3066\u306f\u307b\u3068\u3093\u3069\u691c\u8a0e\u3055\u308c\u3066\u3044\u306a\u3044\u3001\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u5b9f\u969b\u306e\u3068\u3053\u308d\u30e1\u30bd\u30c3\u30c9\u8981\u4ef6\u3092\u30af\u30ea\u30a2\u3059\u308b\u3053\u3068\u3001\u7279\u306b\u6c7a\u5b9a\u4fc2\u6570\uff08r\u00b2\uff09\u306e\u5024\u3092\u91cd\u8996\u3057\u3059\u304e\u308b\u3053\u3068\u3067\u3001\u304b\u3048\u3063\u3066\u5206\u6790\u7cbe\u5ea6\u3092\u60aa\u5316\u3055\u305b\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u70b9\u306b\u3064\u3044\u3066\u306fTO-15A\u306e\u30d6\u30ed\u30b0\u3067\u3082\u8efd\u304f\u89e6\u308c\u3066\u307e\u3057\u305f\u3002r\u00b2\u5024\u306f\u300c\u7d76\u5bfe\u8aa4\u5dee\u300d\u306b\u57fa\u3065\u3044\u3066\u7b97\u51fa\u3055\u308c\u308b\u305f\u3081\u3001r\u00b2\u3092\u6700\u5927\u5316\u3059\u308b\u3053\u3068\u3060\u3051\u3092\u76ee\u7684\u306b\u691c\u91cf\u7dda\u306e\u30d5\u30a3\u30c3\u30c6\u30a3\u30f3\u30b0\u3092\u884c\u3046\u3068\u3001\u5168\u6fc3\u5ea6\u7bc4\u56f2\u306b\u308f\u305f\u308b\u300c\u7d76\u5bfe\u8aa4\u5dee\u300d\u306e\u6700\u5c0f\u5316\u306b\u504f\u308a\u304c\u751f\u3058\u3084\u3059\u304f\u3001\u7279\u306b\u4f4e\u6fc3\u5ea6\u9818\u57df\u3067\u306f\u300c\u76f8\u5bfe\u8aa4\u5dee\u300d\u304c\u5927\u304d\u304f\u306a\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u554f\u984c\u306b\u3064\u3044\u3066\u306f\u3001Eurofins\u793e\u306eRichard Burrows\u6c0f\u304cNEMC 2020\u3067<a href=\"https:\/\/apps.nelac-institute.org\/nemc\/2020\/docs\/presentations\/pdf\/8-12-20-Collaborative%20Efforts%20to%20Improve%20Environmental%20Monitoring-16.01-Burrows.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u7d20\u6674\u3089\u3057\u3044\u30d7\u30ec\u30bc\u30f3\u30c6\u30fc\u30b7\u30e7\u30f3<\/a>\u3092\u884c\u3063\u3066\u304a\u308a\u3001\u6570\u5b66\u7684\u306a\u80cc\u666f\u307e\u3067\u6398\u308a\u4e0b\u3052\u3066\u89e3\u8aac\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00b110%\u57fa\u6e96\u3068\u306f\uff1f\u4ed6\u306ePFAS\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u3068\u306e\u6bd4\u8f03<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">TO-15A\u306e\u30d6\u30ed\u30b0\u306e\u6642\u70b9\u304b\u3089\u3001\u30ad\u30e3\u30ea\u30d6\u30ec\u30fc\u30b7\u30e7\u30f3\u8a55\u4fa1\u306b\u304a\u3051\u308br\u00b2\u5024\u306e\u6271\u3044\u306b\u5927\u304d\u306a\u5909\u66f4\u304c\u3042\u3063\u305f\u306e\u3067\u3001\u518d\u5ea6\u3053\u306e\u70b9\u306b\u89e6\u308c\u3066\u3044\u307e\u3059\u3002\u5177\u4f53\u7684\u306b\u306f\u3001OTM-45\u306fEPA Method 533\u304a\u3088\u3073537.1\uff08\u98f2\u6599\u6c34\u4e2d\u306ePFAS\u5206\u6790\u65b9\u6cd5\uff09\u306b\u5023\u3044\u3001\u691c\u91cf\u7dda\u306e\u5408\u5426\u5224\u5b9a\u6307\u6a19\u3068\u3057\u3066\u6c7a\u5b9a\u4fc2\u6570\uff08r\u00b2\uff09\u3084\u5e73\u5747\u5fdc\u7b54\u4fc2\u6570\u66f2\u7dda\u306e\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\uff08%RSD\uff09\u306e\u4f7f\u7528\u3092\u3084\u3081\u307e\u3057\u305f\u3002\u552f\u4e00\u306e\u8981\u4ef6\u306f\u3001\u6821\u6b63\u70b9\u306e\u7b97\u51fa\u5024\u304c\u771f\u5024\u306e\u00b110%\u4ee5\u5185\u3067\u3042\u308b\u3053\u3068\uff08\u4ee5\u964d\u00b110%\u3068\u8868\u8a18\uff09\u3067\u3059\u3002\u3053\u308c\u306f\u826f\u3044\u9762\u3082\u3042\u308c\u3070\u3001\u6f5c\u5728\u7684\u306b\u554f\u984c\u3068\u306a\u308b\u9762\u3082\u3042\u308a\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u66f2\u7dda\u306e\u8a55\u4fa1\u304c\u3001r\u00b2\u3084%RSD\u3068\u3044\u3063\u305f\u7d71\u8a08\u7684\u6307\u6a19\u3067\u306f\u306a\u304f\u3001\u6fc3\u5ea6\u3054\u3068\u306e\u6e2c\u5b9a\u7cbe\u5ea6\uff08\u76f8\u5bfe\u8aa4\u5dee\uff09\u306b\u57fa\u3065\u3044\u3066\u3044\u308b\u305f\u3081\u3001\u5168\u6fc3\u5ea6\u7bc4\u56f2\u306b\u304a\u3051\u308b\u5b9a\u91cf\u306e\u4fe1\u983c\u6027\u3092\u3088\u308a\u9069\u5207\u306b\u53cd\u6620\u3057\u3066\u3044\u308b\u3001\u3068\u3044\u3046\u306e\u306f\u5229\u70b9\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002\u4e00\u65b9\u3067\u554f\u984c\u3068\u306a\u308a\u5f97\u308b\u306e\u306f\u3001\u00b110%\u3068\u3044\u3046\u56de\u53ce\u7387\u306e\u8a31\u5bb9\u7bc4\u56f2\u304c\u975e\u5e38\u306b\u53b3\u3057\u304f\u3001\u591a\u304f\u306e\u30e9\u30dc\u304c\u9054\u6210\u306b\u82e6\u52b4\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u70b9\u3067\u3059\u3002EPA Method 533\u304a\u3088\u3073537.1\u3067\u306f\u3001\u8a31\u5bb9\u7bc4\u56f2\u304c\u00b130%\u3001\u3042\u308b\u3044\u306f\u6700\u5c0f\u5831\u544a\u9650\u754c\u4ee5\u4e0b\u306e\u70b9\u3067\u306f\u00b150%\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002TO-15A\u3067\u306fr\u00b2\u3084%RSD\u306e\u8981\u4ef6\u306f\u7dad\u6301\u3055\u308c\u3066\u3044\u307e\u3059\u304c\u3001\u56de\u53ce\u7387\u306e\u8a31\u5bb9\u7bc4\u56f2\u306f\u00b130%\u306b\u8a2d\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002OTM-45\u3067\u884c\u308f\u308c\u305f\u691c\u8a3c\u3067\u306f\u300149\u5316\u5408\u7269\u4e2d\u3001\u00b110%\u4ee5\u5185\u306b\u53ce\u307e\u3063\u305f\u3082\u306e\u306f12\u5316\u5408\u7269\u300110\u301c20%\u306e\u7bc4\u56f2\u306b\u5165\u3063\u305f\u3082\u306e\u304c32\u5316\u5408\u7269\u300120\u301c30%\u304c5\u5316\u5408\u7269\u3001\u305d\u3057\u306630%\u3092\u8d85\u3048\u305f\u3082\u306e\u306f\u3042\u308a\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3064\u307e\u308a\u3001\u00b110%\u57fa\u6e96\u3092\u6e80\u305f\u3055\u306a\u304b\u3063\u305f\u5316\u5408\u7269\u306f37\u7a2e\u306b\u306e\u307c\u308b\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002\u8a73\u3057\u3044\u7d50\u679c\u306fTable 1\u3092\u3054\u53c2\u7167\u4e0b\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">OTM-45\u306e\u6821\u6b63\u7d50\u679c\uff1a\u00b110%\u4ee5\u5185\u306b\u53ce\u307e\u3089\u306a\u304b\u3063\u305f\u5316\u5408\u7269<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td>PFBA<\/td><td>PF4OPeA<\/td><td>3:3 FTCA<\/td><td>PFPeA<\/td><td>PFBS<\/td><td>PF5OHxA<\/td><td>PFEESA<\/td><td>3,6-OPFHpA<\/td><td>&nbsp;<\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 1<\/td><td>112%<\/td><td>114%<\/td><td>89%<\/td><td>101%<\/td><td>114%<\/td><td>97%<\/td><td>94%<\/td><td>92%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 2<\/td><td>113%<\/td><td>104%<\/td><td>120%<\/td><td>100%<\/td><td>110%<\/td><td>93%<\/td><td>99%<\/td><td>111%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 3<\/td><td>96%<\/td><td>98%<\/td><td>113%<\/td><td>98%<\/td><td>108%<\/td><td>97%<\/td><td>100%<\/td><td>105%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 4<\/td><td>94%<\/td><td>105%<\/td><td>89%<\/td><td>96%<\/td><td>102%<\/td><td>92%<\/td><td>90%<\/td><td>102%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 5<\/td><td>103%<\/td><td>107%<\/td><td>82%<\/td><td>94%<\/td><td>106%<\/td><td>94%<\/td><td>91%<\/td><td>108%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 6<\/td><td>88%<\/td><td>94%<\/td><td>90%<\/td><td>101%<\/td><td>101%<\/td><td>98%<\/td><td>95%<\/td><td>107%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 7<\/td><td>91%<\/td><td>101%<\/td><td>117%<\/td><td>110%<\/td><td>99%<\/td><td>101%<\/td><td>102%<\/td><td>98%<\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"10\">&nbsp;<\/td><\/tr><tr><td>&nbsp;<\/td><td>4-2 FTS<\/td><td>PFHxA<\/td><td>PFPeS<\/td><td>HFPD-DA<\/td><td>PFHpA<\/td><td>5:3 FTCA<\/td><td>FHUEA<\/td><td>PFHxS<\/td><td>&nbsp;<\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 1<\/td><td>109%<\/td><td>100%<\/td><td>95%<\/td><td>119%<\/td><td>110%<\/td><td>101%<\/td><td>95%<\/td><td>89%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 2<\/td><td>100%<\/td><td>108%<\/td><td>103%<\/td><td>115%<\/td><td>103%<\/td><td>103%<\/td><td>89%<\/td><td>101%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 3<\/td><td>116%<\/td><td>99%<\/td><td>99%<\/td><td>87%<\/td><td>102%<\/td><td>95%<\/td><td>88%<\/td><td>105%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 4<\/td><td>97%<\/td><td>95%<\/td><td>97%<\/td><td>99%<\/td><td>97%<\/td><td>85%<\/td><td>81%<\/td><td>75%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 5<\/td><td>96%<\/td><td>99%<\/td><td>98%<\/td><td>105%<\/td><td>99%<\/td><td>107%<\/td><td>89%<\/td><td>104%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 6<\/td><td>94%<\/td><td>98%<\/td><td>102%<\/td><td>99%<\/td><td>99%<\/td><td>110%<\/td><td>81%<\/td><td>101%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 7<\/td><td>89%<\/td><td>101%<\/td><td>100%<\/td><td>100%<\/td><td>100%<\/td><td>99%<\/td><td>105%<\/td><td>100%<\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"10\">&nbsp;<\/td><\/tr><tr><td>&nbsp;<\/td><td>FHEA<\/td><td>ADONA<\/td><td>PFeCHS<\/td><td>6-2 FTS<\/td><td>PFHpS<\/td><td>PFOA<\/td><td>PFOS<\/td><td>FOUEA<\/td><td>&nbsp;<\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 1<\/td><td>117%<\/td><td>99%<\/td><td>97%<\/td><td>101%<\/td><td>113%<\/td><td>105%<\/td><td>93%<\/td><td>116%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 2<\/td><td>74%<\/td><td>92%<\/td><td>96%<\/td><td>103%<\/td><td>100%<\/td><td>107%<\/td><td>102%<\/td><td>92%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 3<\/td><td>119%<\/td><td>90%<\/td><td>98%<\/td><td>118%<\/td><td>95%<\/td><td>101%<\/td><td>81%<\/td><td>87%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 4<\/td><td>100%<\/td><td>90%<\/td><td>93%<\/td><td>106%<\/td><td>86%<\/td><td>99%<\/td><td>99%<\/td><td>102%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 5<\/td><td>88%<\/td><td>90%<\/td><td>105%<\/td><td>99%<\/td><td>95%<\/td><td>103%<\/td><td>96%<\/td><td>100%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 6<\/td><td>103%<\/td><td>93%<\/td><td>100%<\/td><td>104%<\/td><td>104%<\/td><td>102%<\/td><td>103%<\/td><td>97%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 7<\/td><td>100%<\/td><td>102%<\/td><td>100%<\/td><td>99%<\/td><td>100%<\/td><td>100%<\/td><td>100%<\/td><td>120%<\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"10\">&nbsp;<\/td><\/tr><tr><td>&nbsp;<\/td><td>PFNA<\/td><td>FHpPA<\/td><td>FOEA<\/td><td>9Cl-PF3ONS<\/td><td>L-PFNS<\/td><td>PFDA<\/td><td>8-2 FTS<\/td><td>L-PFDS<\/td><td>&nbsp;<\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 1<\/td><td>98%<\/td><td>115%<\/td><td>114%<\/td><td>81%<\/td><td>106%<\/td><td>105%<\/td><td>91%<\/td><td>107%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 2<\/td><td>116%<\/td><td>80%<\/td><td>108%<\/td><td>99%<\/td><td>116%<\/td><td>103%<\/td><td>83%<\/td><td>73%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 3<\/td><td>102%<\/td><td>127%<\/td><td>104%<\/td><td>107%<\/td><td>85%<\/td><td>109%<\/td><td>108%<\/td><td>128%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 4<\/td><td>98%<\/td><td>96%<\/td><td>81%<\/td><td>103%<\/td><td>104%<\/td><td>93%<\/td><td>107%<\/td><td>103%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 5<\/td><td>100%<\/td><td>104%<\/td><td>110%<\/td><td>104%<\/td><td>99%<\/td><td>96%<\/td><td>107%<\/td><td>94%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 6<\/td><td>94%<\/td><td>99%<\/td><td>98%<\/td><td>104%<\/td><td>88%<\/td><td>100%<\/td><td>106%<\/td><td>88%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 7<\/td><td>92%<\/td><td>100%<\/td><td>100%<\/td><td>103%<\/td><td>102%<\/td><td>100%<\/td><td>98%<\/td><td>108%<\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"10\">&nbsp;<\/td><\/tr><tr><td>&nbsp;<\/td><td>FDEA<\/td><td>PFUnA<\/td><td>11Cl-PF3OUdS<\/td><td>FOSA-I<\/td><td>10:2 FTS<\/td><td>PFDoA<\/td><td>PFDoS<\/td><td>N-MeFOSA-M<\/td><td>&nbsp;<\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 1<\/td><td>98%<\/td><td>117%<\/td><td>81%<\/td><td>107%<\/td><td>94%<\/td><td>91%<\/td><td>98%<\/td><td>92%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 2<\/td><td>118%<\/td><td>113%<\/td><td>84%<\/td><td>93%<\/td><td>116%<\/td><td>113%<\/td><td>107%<\/td><td>87%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 3<\/td><td>107%<\/td><td>103%<\/td><td>98%<\/td><td>89%<\/td><td>119%<\/td><td>102%<\/td><td>98%<\/td><td>91%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 4<\/td><td>99%<\/td><td>102%<\/td><td>97%<\/td><td>97%<\/td><td>98%<\/td><td>101%<\/td><td>96%<\/td><td>104%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 5<\/td><td>119%<\/td><td>99%<\/td><td>95%<\/td><td>95%<\/td><td>91%<\/td><td>96%<\/td><td>90%<\/td><td>93%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 6<\/td><td>90%<\/td><td>97%<\/td><td>96%<\/td><td>96%<\/td><td>103%<\/td><td>98%<\/td><td>97%<\/td><td>102%<\/td><td>&nbsp;<\/td><\/tr><tr><td>Cal 7<\/td><td>87%<\/td><td>101%<\/td><td>101%<\/td><td>101%<\/td><td>100%<\/td><td>100%<\/td><td>114%<\/td><td>100%<\/td><td>&nbsp;<\/td><\/tr><tr><td colspan=\"10\">&nbsp;<\/td><\/tr><tr><td>&nbsp;<\/td><td>N-Me-FOSE-M<\/td><td>N-MeFOSAA<\/td><td>PFHxDA<\/td><td>N-EtFOSA-M<\/td><td>N-EtFOSE-M<\/td><td>N-EtFOSAA<\/td><td>PFODA<\/td><td>PFTrDA<\/td><td>PFTA<\/td><\/tr><tr><td>\u30b5\u30f3\u30d7\u30eb<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><td>\u7cbe\u5ea6<\/td><\/tr><tr><td>Cal 1<\/td><td>100%<\/td><td>106%<\/td><td>81%<\/td><td>112%<\/td><td>100%<\/td><td>119%<\/td><td>112%<\/td><td>98%<\/td><td>109%<\/td><\/tr><tr><td>Cal 2<\/td><td>100%<\/td><td>94%<\/td><td>103%<\/td><td>97%<\/td><td>104%<\/td><td>114%<\/td><td>115%<\/td><td>101%<\/td><td>88%<\/td><\/tr><tr><td>Cal 3<\/td><td>129%<\/td><td>106%<\/td><td>96%<\/td><td>89%<\/td><td>97%<\/td><td>100%<\/td><td>94%<\/td><td>89%<\/td><td>95%<\/td><\/tr><tr><td>Cal 4<\/td><td>79%<\/td><td>88%<\/td><td>89%<\/td><td>98%<\/td><td>93%<\/td><td>104%<\/td><td>86%<\/td><td>92%<\/td><td>100%<\/td><\/tr><tr><td>Cal 5<\/td><td>92%<\/td><td>111%<\/td><td>95%<\/td><td>105%<\/td><td>95%<\/td><td>110%<\/td><td>84%<\/td><td>101%<\/td><td>95%<\/td><\/tr><tr><td>Cal 6<\/td><td>100%<\/td><td>99%<\/td><td>85%<\/td><td>100%<\/td><td>112%<\/td><td>91%<\/td><td>87%<\/td><td>96%<\/td><td>91%<\/td><\/tr><tr><td>Cal 7<\/td><td>100%<\/td><td>100%<\/td><td>104%<\/td><td>100%<\/td><td>99%<\/td><td>101%<\/td><td>105%<\/td><td>101%<\/td><td>102%<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Table 1: \u6821\u6b63\u7cbe\u5ea6\uff08\u8aa4\u5dee\uff09\u306e\u7d50\u679c<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00b110%\u57fa\u6e96\u3092\u6e80\u305f\u305b\u306a\u3044\u539f\u56e0\u306f\u3069\u3053\u306b\u3042\u308b\u306e\u304b\uff1f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u3088\u3046\u306b\u00b110%\u57fa\u6e96\u3092\u6e80\u305f\u3055\u306a\u3044\u5316\u5408\u7269\u304c\u591a\u304b\u3063\u305f\u3068\u3044\u3046\u7d50\u679c\u306f\u3001\u8907\u6570\u56de\u6821\u6b63\u3092\u8a66\u884c\u3057\u305f\u306a\u304b\u3067\u3082\u4e00\u8cab\u3057\u3066\u3044\u307e\u3057\u305f\u3002\u305d\u3053\u3067\u3001\u8003\u3048\u3089\u308c\u308b\u539f\u56e0\u3092\u4ee5\u4e0b\u306e\u3088\u3046\u306b\u691c\u8a0e\u3057\u3066\u307f\u307e\u3059\u3002<strong>\u7279\u5b9a\u306e\u6a19\u6e96\u54c1\u306e\u554f\u984c\u306a\u306e\u304b\uff1f<\/strong>\u00b110%\u57fa\u6e96\u304c\u6e80\u305f\u3055\u308c\u306a\u3044\u306e\u306f\u7279\u5b9a\u306e\u6821\u6b63\u70b9\u306b\u4e00\u8cab\u3057\u3066\u8d77\u304d\u3066\u3044\u308b\u308f\u3051\u3067\u306f\u306a\u304b\u3063\u305f\u306e\u3067\u3001\u3053\u308c\u306f\u9055\u3046\u3067\u3057\u3087\u3046\u3002\u3067\u306f\u3001<strong>\u5358\u767a\u306e\u30b9\u30d1\u30a4\u30af\u30b5\u30f3\u30d7\u30eb\u306b\u95a2\u9023\u3057\u3066\u3044\u308b\u306e\u304b\uff1f<\/strong>\u6821\u6b63\u7528\u6a19\u6e96\u6eb6\u6db2\u306f\u3059\u3079\u3066\u3001\u540c\u4e00\u6761\u4ef6\u3067\u8abf\u88fd\u3057\u305f\u5358\u4e00\u306e\u30b9\u30c8\u30c3\u30af\u6eb6\u6db2\u304b\u3089\u5e0c\u91c8\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u3053\u308c\u3082\u8003\u3048\u3089\u308c\u307e\u305b\u3093\u3002<strong>\u5185\u90e8\u6a19\u6e96\u306e\u554f\u984c\u306a\u306e\u304b\uff1f<\/strong>\u5185\u90e8\u6a19\u6e96\u306e\u30d4\u30fc\u30af\u9762\u7a4d\u3082\u5b89\u5b9a\u3057\u3066\u304a\u308a\u3001\u540c\u3058\u5185\u90e8\u6a19\u6e96\u3092\u5171\u6709\u3059\u308b\u5316\u5408\u7269\u306e\u4e2d\u3067\u3082\u00b110%\u306e\u57fa\u6e96\u4ee5\u5185\u306e\u3082\u306e\u3068\u8d85\u3048\u305f\u3082\u306e\u304c\u6df7\u5728\u3057\u3066\u3044\u305f\u305f\u3081\u3001\u305d\u3046\u3068\u306f\u8003\u3048\u306b\u304f\u3044\u72b6\u6cc1\u3067\u3057\u305f\u3002\u57fa\u6e96\u3092\u6e80\u305f\u3057\u305f\u5316\u5408\u7269\u306f\u3059\u3079\u3066\u3001\u30da\u30eb\u30d5\u30eb\u30aa\u30ed\u30a2\u30eb\u30ad\u30eb\u30ab\u30eb\u30dc\u30f3\u9178\uff08PFCA\uff09\u304b\u3001OTM-45\u3067\u3042\u3044\u307e\u3044\u306b\u300c\u8ffd\u52a0\u30bf\u30fc\u30b2\u30c3\u30c8\u300d\u3068\u547c\u3070\u308c\u308b\u30b0\u30eb\u30fc\u30d7\u306b\u5c5e\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u3053\u308c\u3089\u306f\u30e1\u30bd\u30c3\u30c9\u3067\u6271\u3046\u4e2d\u3067\u6700\u5927\u306e\u5316\u5408\u7269\u7fa4\u3067\u3042\u308b\u305f\u3081\u3001\u5fc5\u305a\u3057\u3082\u610f\u5473\u306e\u3042\u308b\u50be\u5411\u3068\u306f\u8a00\u3048\u307e\u305b\u3093\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u00b110%\u57fa\u6e96\u306f\u5b9f\u7528\u7684\u304b\uff1f\u4eca\u5f8c\u306e\u30e9\u30dc\u904b\u7528\u3067\u8003\u3048\u308b\u3079\u304d\u3053\u3068<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u7d50\u5c40\u306e\u3068\u3053\u308d\u3001\u00b110%\u57fa\u6e96\u3092\u6e80\u305f\u3055\u306a\u3044\u3053\u3068\u306b\u5171\u901a\u3059\u308b\u539f\u56e0\u306f\u7279\u5b9a\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u3001\u73fe\u72b6\u306e\u7d50\u679c\u3092\u53d7\u3051\u5165\u308c\u308b\u3053\u3068\u306b\u3057\u307e\u3057\u305f\u3002\u306a\u305c\u306a\u3089\u4ed6\u306ePFAS\u5206\u6790\u30e1\u30bd\u30c3\u30c9\u306e\u57fa\u6e96\u306f\u6e80\u305f\u3057\u3066\u3044\u305f\u305f\u3081\u3001OTM-45\u3067\u6c42\u3081\u3089\u308c\u3066\u3044\u308b\u975e\u5e38\u306b\u53b3\u3057\u3044\u00b110%\u57fa\u6e96\u306b\u7121\u7406\u306b\u5408\u308f\u305b\u308b\u5fc5\u8981\u306f\u306a\u3044\u3068\u8003\u3048\u305f\u304b\u3089\u3067\u3059\u3002\u307e\u305f\u3001\u6821\u6b63\u7d50\u679c\u306f\u591a\u304f\u306e\u4ed6\u306e\u30e1\u30bd\u30c3\u30c9\u3067\u306f\u8a31\u5bb9\u7bc4\u56f2\u5185\u3067\u3042\u3063\u305f\u3053\u3068\u3082\u3042\u308a\u3001\u62bd\u51fa\u306a\u3069\u30e1\u30bd\u30c3\u30c9\u306e\u4ed6\u306e\u90e8\u5206\u3092\u6539\u5584\u3059\u308b\u65b9\u304c\u4fa1\u5024\u304c\u3042\u308b\u3068\u3082\u8003\u3048\u307e\u3057\u305f\u3002\u3082\u3057\u00b110%\u57fa\u6e96\u304c\u30c9\u30e9\u30d5\u30c8\u7248\u304b\u3089\u6700\u7d42\u7248\u306b\u5f15\u304d\u7d99\u304c\u308c\u308b\u306a\u3089\u3070\u3001\u3053\u306e\u30e1\u30bd\u30c3\u30c9\u3092\u5b9f\u65bd\u3059\u308b\u30e9\u30dc\u3067\u306f\u3053\u306e\u3088\u3046\u306a\u5224\u65ad\u304c\u5fc5\u8981\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u30b5\u30f3\u30d7\u30eb\u306e\u7279\u6027\u3092\u3088\u304f\u7406\u89e3\u3057\u3066\u3044\u308b\u30e9\u30dc\u3067\u3042\u308c\u3070\u3001\u5bfe\u8c61\u5316\u5408\u7269\u30ea\u30b9\u30c8\u3084\u6821\u6b63\u7bc4\u56f2\u3092\u4e88\u60f3\u3055\u308c\u308b\u6210\u5206\u306b\u9650\u5b9a\u3059\u308b\u3053\u3068\u3067\u3001\u00b110%\u57fa\u6e96\u306e\u9054\u6210\u304c\u5bb9\u6613\u306b\u306a\u308b\u304b\u3082\u3057\u308c\u307e\u305b\u3093\u3002\u3057\u304b\u3057\u3001\u3059\u3079\u3066\u306e\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u00b110%\u57fa\u6e96\u3092\u30af\u30ea\u30a2\u3059\u308b\u306e\u306f\u591a\u304f\u306e\u30e9\u30dc\u306b\u3068\u3063\u3066\u53b3\u3057\u3044\u8ab2\u984c\u306b\u306a\u308b\u3053\u3068\u306f\u9593\u9055\u3044\u306a\u3044\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4767-ja\/pfas-in-air-part-1-otm-45-japan\">\uff1c\u7b2c1\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u6982\u8981<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4768-ja\/pfas-in-air-part-2-otm-45-japan\">\uff1c\u7b2c2\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306b\u57fa\u3065\u3044\u305f\u6700\u9069\u5316<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/press-releases-news-ja\/gnbl4770-ja\/pfas-in-air-part-4-otm-45-resin-cleaning-japan\">\uff1c\u7b2c4\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30ec\u30b8\u30f3\u6d17\u6d44<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4771-ja\/pfas-in-air-part-5-resin-extraction-japan\">\uff1c\u7b2c5\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30ec\u30b8\u30f3\u62bd\u51fa<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>EPA\u304c\u767a\u8868\u3057\u305fPFAS\u6392\u30ac\u30b9\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3068\u5206\u6790\u306e\u30e1\u30bd\u30c3\u30c9OTM-45\u3092\u89e3\u8aac\u3002\u56fa\u5b9a\u767a\u751f\u6e90PFAS\u691c\u67fb\u306b\u5fc5\u8981\u306a\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u624b\u9806\u3084LC-MS\/MS\u5206\u6790\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u521d\u5fc3\u8005\u306b\u3082\u308f\u304b\u308a\u3084\u3059\u304f\u7d39\u4ecb\u3057\u307e\u3059\u3002\u7b2c3\u56de\u306f\u88c5\u7f6e\u6821\u6b63\u306e\u91cd\u8981\u6027\u3068\u8ab2\u984c\u3092\u63a2\u308a\u307e\u3059\u3002r\u00b2 \u3084 %RSD \u306b\u4ee3\u308f\u308b \u00b110% \u57fa\u6e96\u306e\u5c0e\u5165\u7d4c\u7def\u3001\u5b9f\u969b\u306e\u6821\u6b63\u7d50\u679c\u3001\u305d\u3057\u3066\u30e9\u30dc\u904b\u7528\u3067\u6ce8\u610f\u3059\u3079\u304d\u30dd\u30a4\u30f3\u30c8\u3092\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":27,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2760],"industries-application":[2288,2272,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2365,2339,2343],"ppma_author":[447],"class_list":["post-71505","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-air-monitoring-ja","industries-application-environmental-ja","resource-technique-ms-ms-ja","resource-technique-air-sampling-ja","resource-technique-liquid-chromatography-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2272,"label":"\u5927\u6c17 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2365,"label":"MS\/MS"},{"value":2339,"label":"\u30a8\u30a2\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"},{"value":2343,"label":"\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jason Hoisington","author_link":"https:\/\/discover.restek.com\/ja\/author\/jason-hoisington\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":447,"user_id":27,"is_guest":0,"slug":"jason-hoisington","display_name":"Jason Hoisington","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg"},"author_category":"1","first_name":"Jason","last_name":"Hoisington","user_url":"https:\/\/www.linkedin.com\/in\/jason-hoisington-73067653\/","job_title":"Principal Scientist, Sample Preparation","description":"Jason Hoisington received his bachelor\u2019s degree in general science with a focus on chemistry from the University of Alaska, Fairbanks. He worked for SGS Environmental for seven years in environmental soil and water testing, developing methods for the analysis of volatiles and semivolatile organics to include pesticides and polychlorinated biphenyls (PCBs). In 2012, Jason moved on to lab and application support for Dow Chemical Company, providing advanced analytical troubleshooting and method development. In 2019, Jason joined Restek and has focused on air applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71505","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71505"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71505\/revisions"}],"predecessor-version":[{"id":93986,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71505\/revisions\/93986"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71505"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71505"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71505"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71505"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71505"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71505"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71505"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71505"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71505"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}