{"id":71508,"date":"2022-05-02T14:30:00","date_gmt":"2022-05-02T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71508"},"modified":"2026-04-28T19:42:57","modified_gmt":"2026-04-28T19:42:57","slug":"pfas-in-air-part-4-otm-45-resin-cleaning-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/press-releases-news-ja\/gnbl4770-ja\/pfas-in-air-part-4-otm-45-resin-cleaning-japan","title":{"rendered":"PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u7b2c4\u56de\uff1a \u30ec\u30b8\u30f3\u6d17\u6d44"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6700\u7d42\u66f4\u65b0\u65e5\uff1a2025\u5e7410\u670810\u65e5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">OTM-45\u306b\u304a\u3051\u308b\u30ec\u30b8\u30f3\u6d17\u6d44\u306e\u91cd\u8981\u6027\u3068\u306f<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u30d6\u30ed\u30b0\u30b7\u30ea\u30fc\u30ba\u7b2c1\u56de\u3067\u306fOTM-45\u306e\u6982\u8981\u3001\u7b2c2\u56de\u3067\u306f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306b\u57fa\u3065\u3044\u305f\u5206\u6790\u6761\u4ef6\u306e\u8abf\u6574\u306b\u3064\u3044\u3066\u3001\u7b2c3\u56de\u3067\u306f\u30e1\u30bd\u30c3\u30c9\u304c\u898f\u5b9a\u3059\u308b\u6821\u6b63\u8981\u4ef6\u3068\u305d\u308c\u306b\u95a2\u9023\u3059\u308b\u554f\u984c\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u7b2c4\u56de\u306fDionex ASE 350\u30b7\u30b9\u30c6\u30e0\u3092\u4f7f\u7528\u3057\u305f\u30ec\u30b8\u30f3\u6d17\u6d44\u624b\u9806\u306b\u3064\u3044\u3066\u6398\u308a\u4e0b\u3052\u3066\u3044\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">OTM-45\u304c\u793a\u3059\u30ec\u30b8\u30f3\u6d17\u6d44\u306e\u6a19\u6e96\u624b\u9806<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305a\u3001\u30ec\u30b8\u30f3\u6d17\u6d44\u306b\u3064\u3044\u3066\u5c11\u3057\u304a\u8a71\u3057\u3057\u307e\u3057\u3087\u3046\u3002Restek\u306fClean SDVB\u30ec\u30b8\u30f3\uff08\u4ed6\u30e1\u30fc\u30ab\u30fc\u306e\u524d\u6d17\u6d44\u6e08XAD-2\u30ec\u30b8\u30f3\u3068\u540c\u7b49\uff09\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002OTM-45\u306f\u305d\u306e\u4ed8\u9332\u306b\u304a\u3044\u3066\u3001Clean SDVB\u30ec\u30b8\u30f3\u3084\u524d\u6d17\u6d44\u6e08\u30ec\u30b8\u30f3\u3092\u8cfc\u5165\u305b\u305a\u306b\u672a\u52a0\u5de5\u30ec\u30b8\u30f3\u3092\u6d17\u6d44\u3059\u308b\u5834\u5408\u306e\u5fc5\u8981\u306a\u624b\u9806\u6982\u8aac\u3092\u8a18\u8f09\u3057\u3066\u3044\u307e\u3059\u3002\u4ee5\u4e0b\u306f\u3001\u5fae\u751f\u7269\u306e\u5897\u6b96\u3092\u9632\u3050\u305f\u3081\u306bXAD-2\u306b\u6dfb\u52a0\u3055\u308c\u305f\u5869\u3092\u9664\u53bb\u3057\u3001\u4f7f\u7528\u524d\u306b\u5b8c\u5168\u306b\u30af\u30ea\u30fc\u30f3\u306a\u72b6\u614b\u306b\u3059\u308b\u624b\u9806\u3067\u3059\u3002\u307e\u305a\u3001<strong>\u6c34\u306b\u4e00\u6669\u6d78\u6f2c<\/strong>\u3057\u3001\u4ee5\u4e0b<strong>4\u6bb5\u968e\u306e\u62bd\u51fa<\/strong>\u3092\u884c\u3044\u307e\u3059\u3002\u2460\u71b1\u6c34\u306b\u3088\u308b8\u6642\u9593\u306e\u30bd\u30c3\u30af\u30b9\u30ec\u30fc\u62bd\u51fa\u3001\u2461\u30e1\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b22\u6642\u9593\u306e\u30bd\u30c3\u30af\u30b9\u30ec\u30fc\u62bd\u51fa\u3001\u2462\u5869\u5316\u30e1\u30c1\u30ec\u30f3\u306b\u3088\u308b22\u6642\u9593\u306e\u30bd\u30c3\u30af\u30b9\u30ec\u30fc\u62bd\u51fa\u3001\u24635\uff05\u6c34\u9178\u5316\u30a2\u30f3\u30e2\u30cb\u30a6\u30e0\u3092\u542b\u3080\u30e1\u30bf\u30ce\u30fc\u30eb\u306b\u3088\u308b22\u6642\u9593\u306e\u6700\u7d42\u30bd\u30c3\u30af\u30b9\u30ec\u30fc\u62bd\u51fa\u3067\u3059\u3002\u6700\u5f8c\u306b\u3001<strong>\u7a92\u7d20\u3092\u4f7f\u3063\u3066\u6a39\u8102\u3092\u4e7e\u71e5<\/strong>\u3055\u305b\u307e\u3059\u304c\u3001\u3053\u306e\u65b9\u6cd5\u3067\u306f500 g\u306eXAD-2\u3092\u4e7e\u71e5\u3055\u305b\u308b\u306e\u306b\u3001160 L\u30c7\u30e5\u30ef\u30fc\u74f6\u5206\u306e\u6db2\u4f53\u7a92\u7d20\u3092\u4e00\u6669\u4f7f\u3046\u5fc5\u8981\u304c\u3042\u308b\u3068\u8a18\u8f09\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u6eb6\u5a92\u3068\u7a92\u7d20\u306e\u4f7f\u7528\u306b\u52a0\u3048\u3001\u307b\u307c\u4e381\u9031\u9593\u5206\u306e\u4f5c\u696d\u91cf\u304c\u5fc5\u8981\u3067\u3042\u308b\u3053\u3068\u3092\u610f\u5473\u3057\u307e\u3059\u3002\u3053\u308c\u307b\u3069\u306e\u52b4\u529b\u3092\u304b\u3051\u308b\u304f\u3089\u3044\u306a\u3089\u3001\u6700\u521d\u304b\u3089Retek\u306eClean SDVB\u30ec\u30b8\u30f3\u3092\u9078\u3093\u3067\u52b9\u7387\u7684\u306b\u59cb\u3081\u308b\u3079\u304d\u3067\u306f\u306a\u3044\u3067\u3057\u3087\u3046\u304b\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Clean SDVB\u30ec\u30b8\u30f3\u306e\u5229\u70b9\u3068\u8ab2\u984c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3068\u306f\u3044\u3048\u3001Retek\u306eClean SDVB\u30ec\u30b8\u30f3\u3084\u4ed6\u30e1\u30fc\u30ab\u30fc\u306e\u524d\u6d17\u6d44\u6e08XAD-2\u30ec\u30b8\u30f3\u306b\u3082\u3001\u5fae\u91cf\u3067\u3059\u304c\u6b8b\u7559PFAS\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u5b58\u5728\u3057\u306a\u3044\u308f\u3051\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u3001OTM-45\u4ed8\u9332\u306b\u8a18\u8f09\u3055\u308c\u3066\u3044\u308b\u3088\u3046\u306a\u672a\u52a0\u5de5\u30ec\u30b8\u30f3\u306e\u5b8c\u5168\u306a\u6d17\u6d44\u3092\u884c\u3046\u5fc5\u8981\u306f\u306a\u304f\u3001\u6d17\u6d44\u30d7\u30ed\u30bb\u30b9\u306f\u7c21\u6613\u306a\u3082\u306e\u3068\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u7c21\u6613\u306a\u6d17\u6d44\u30d7\u30ed\u30bb\u30b9\u306b\u5bfe\u3057\u3066\u3001Restek\u3067\u306f\u30ec\u30b8\u30f3\u306e\u6d17\u6d44\u3068\u62bd\u51fa\u306e\u4e21\u65b9\u306b\u9ad8\u901f\u6eb6\u5a92\u62bd\u51fa\uff08ASE\uff09\u3092\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u3053\u3068\u306f\u3001<a href=\"https:\/\/apps.nelac-institute.org\/nemc\/2021\/docs\/presentations\/pdf\/8-3-21-Air%20Monitoring,%20Methods,%20and%20Technology-6.01-Hoisington.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">2021\u5e74\u306eNEMC\u3067\u306e\u30d7\u30ec\u30bc\u30f3\u30c6\u30fc\u30b7\u30e7\u30f3<\/a>\u306b\u304a\u3044\u3066\u767a\u8868\u3057\u307e\u3057\u305f\u3002ASE\u306f\u30bd\u30c3\u30af\u30b9\u30ec\u30fc\u62bd\u51fa\u3084\u632f\u3068\u3046\u62bd\u51fa\u306e\u4ee3\u66ff\u3068\u306a\u308b\u3082\u306e\u3067\u3001\u4ed6\u306e\u65b9\u6cd5\u3088\u308a\u3082\u306f\u308b\u304b\u306b\u77ed\u6642\u9593\u3067\u3001\u307b\u3068\u3093\u3069\u624b\u3092\u4f7f\u308f\u305a\u3001\u6eb6\u5a92\u306e\u4f7f\u7528\u91cf\u3082\u5927\u5e45\u306b\u524a\u6e1b\u3067\u304d\u307e\u3059\u3002\u521d\u56deASE\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u3092Table 1\u306b\u793a\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Dionex ASE 350\u30d1\u30e9\u30e1\u30fc\u30bf<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5727\u529b &#8211; 1500 psi<\/li>\n\n\n\n<li>\u6e29\u5ea6 &#8211; 120\u00b0 C<\/li>\n\n\n\n<li>\u52a0\u71b1\u6642\u9593 &#8211; 6\u5206<\/li>\n\n\n\n<li>\u9759\u6b62\u6642\u9593 &#8211; 15\u5206<\/li>\n\n\n\n<li>\u30b5\u30a4\u30af\u30eb &#8211; 2<\/li>\n\n\n\n<li>\u30ea\u30f3\u30b9\u91cf&nbsp;&#8211; 60%<\/li>\n\n\n\n<li>\u6eb6\u5a92 &#8211; 4:1 \u30e1\u30bf\u30ce\u30fc\u30eb:\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Table 1 \u2013\u30ec\u30b8\u30f3\u306e\u6d17\u6d44\u3068\u62bd\u51fa\u306e\u305f\u3081\u306e\u521d\u56deASE<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u521d\u56deASE\u5f8c\u306ePFAS\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306e\u6e2c\u5b9a\u7d50\u679c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Clean SDVB\u30ec\u30b8\u30f3\u3068\u524d\u6d17\u6d44\u6e08XAD-2\u30ec\u30b8\u30f3\u306b\u304a\u3044\u3066ASE\u306b\u3088\u308b\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\/\u62bd\u51fa\u3092\u8a66\u3057\u305f\u3068\u3053\u308d\u3001\u3069\u3061\u3089\u306b\u304a\u3044\u3066\u3082\u4ee5\u4e0b3\u3064\u306ePFAS\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u3001\u304b\u306a\u308a\u9855\u8457\u306a\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u304c\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\uff08Table 2\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table table table-bordered\"><table style=\"border-width:1px\"><tbody><tr><td><strong><strong>\u5316\u5408\u7269\u540d<\/strong><\/strong><\/td><td><strong><strong>ASE\u30d6\u30e9\u30f3\u30af (ng\/g)<\/strong><\/strong><\/td><td><strong>XAD-2 (ng\/g)<\/strong><\/td><td><strong>XAD-2 (ng\/g)<\/strong><\/td><td><strong>XAD-2 (ng\/g)<\/strong><\/td><td><strong>Avg. (ng\/g)<\/strong><\/td><td><strong><strong>Clean SDBV\u30ec\u30b8\u30f3 (ng\/g)<\/strong><\/strong><\/td><td><strong><strong>Clean SDBV\u30ec\u30b8\u30f3 (ng\/g)<\/strong><\/strong><\/td><td><strong><strong>Clean SDBV\u30ec\u30b8\u30f3 (ng\/g)<\/strong><\/strong><\/td><td><strong>Avg. (ng\/g)<\/strong><\/td><\/tr><tr><td>PFBA<\/td><td>0.05<\/td><td>0.54<\/td><td>0.51<\/td><td>0.60<\/td><td><strong>0.55<\/strong><\/td><td>0.43<\/td><td>0.35<\/td><td>0.43<\/td><td><strong>0.40<\/strong><\/td><\/tr><tr><td>PF4OPeA<\/td><td>0.09<\/td><td>0.10<\/td><td>0.11<\/td><td>0.10<\/td><td><strong>0.10<\/strong><\/td><td>0.63<\/td><td>0.45<\/td><td>0.53<\/td><td><strong>0.54<\/strong><\/td><\/tr><tr><td>ADONA<\/td><td>&lt;0.04<\/td><td>0.05<\/td><td>0.05<\/td><td>0.11<\/td><td><strong>0.71<\/strong><\/td><td>0.06<\/td><td>0.04<\/td><td>0.05<\/td><td><strong>0.05<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Table 2 \u2013 ASE\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\/\u62bd\u51fa\u5f8c\u306eXAD-2\u30ec\u30b8\u30f3\u3068Clean SDVB\u30ec\u30b8\u30f3\u306e\u30d6\u30e9\u30f3\u30af\u7d50\u679c\uff08\u300cASE\u30d6\u30e9\u30f3\u30af\u300d\u306f\u3001\u88c5\u7f6e\u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3092\u6e2c\u5b9a\u3059\u308b\u305f\u3081\u306e\u7a7a\u306eASE\u30bb\u30eb\uff09<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u518d\u6d17\u6d44\uff082\u56de\u76ee\u306eASE\uff09\u306b\u3088\u308b\u52b9\u679c\u306e\u691c\u8a3c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u521d\u56deASE\u5f8c\u306b\u691c\u51fa\u3055\u308c\u305f\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306f\u3001\u3053\u308c\u4ee5\u4e0a\u30af\u30ea\u30fc\u30f3\u30a2\u30c3\u30d7\u3067\u304d\u306a\u3044\u3082\u306e\u306a\u306e\u304b\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u306b\u3001\u3069\u3061\u3089\u306e\u30ec\u30b8\u30f3\u3082\u5bfe\u3057\u3066\u30822\u56de\u76ee\u306eASE\u3092\u5b9f\u884c\u3057\u307e\u3057\u305f\u3002\u305d\u306e\u7d50\u679c\u3001Clean SDVB\u30ec\u30b8\u30f3\u3067\u306f\u3001PFBA\u3068PF4OPeA\u306e\u6fc3\u5ea6\u306f\u5927\u5e45\u306b\u4f4e\u4e0b\u3057\u3001ADONA\u306b\u3064\u3044\u3066\u306f\u5909\u5316\u304c\u898b\u3089\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u307e\u305f\u3001XAD-2\u30ec\u30b8\u30f3\u3067\u306f\u3001PFBA\u3068ADONA\u306e\u6fc3\u5ea6\u306b\u3064\u3044\u3066\u306f\u4f4e\u4e0b\u304c\u78ba\u8a8d\u3067\u304d\u305f\u4e00\u65b9\u3067\u3001PF4OPeA\u306e\u6fc3\u5ea6\u306f\u9006\u306b\u4e0a\u6607\u3057\u307e\u3057\u305f\uff08Table 3\u53c2\u7167\uff09\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table table table-bordered\"><table style=\"border-width:1px\"><tbody><tr><td><strong><strong>\u5316\u5408\u7269\u540d<\/strong><\/strong><\/td><td><strong>XAD-2 (ng\/g)<\/strong><\/td><td><strong>XAD-2 (ng\/g)<\/strong><\/td><td><strong>XAD-2 (ng\/g)<\/strong><\/td><td><strong>Avg. (ng\/g)<\/strong><\/td><td><strong><strong>Clean SDBV\u30ec\u30b8\u30f3 (ng\/g)<\/strong><\/strong><\/td><td><strong><strong>Clean SDBV\u30ec\u30b8\u30f3 (ng\/g)<\/strong><\/strong><\/td><td><strong><strong>Clean SDBV\u30ec\u30b8\u30f3 (ng\/g)<\/strong><\/strong><\/td><td><strong>Avg. (ng\/g)<\/strong><\/td><\/tr><tr><td>PFBA<\/td><td>0.29<\/td><td>0.24<\/td><td>0.28<\/td><td><strong>0.27<\/strong><\/td><td>0.12<\/td><td>0.18<\/td><td>0.10<\/td><td><strong>0.13<\/strong><\/td><\/tr><tr><td>PF4OPeA<\/td><td>0.37<\/td><td>0.29<\/td><td>0.24<\/td><td><strong>0.30<\/strong><\/td><td>0.06<\/td><td>0.09<\/td><td>0.10<\/td><td><strong>0.08<\/strong><\/td><\/tr><tr><td>ADONA<\/td><td>0.71<\/td><td>0.25<\/td><td>0.30<\/td><td><strong>0.42<\/strong><\/td><td>0.05<\/td><td>0.08<\/td><td>0.04<\/td><td><strong>0.06<\/strong><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Table 3 \u2013 XAD-2\u30ec\u30b8\u30f3\u3068Clean SDVB\u30ec\u30b8\u30f3\u306e2\u56de\u76ee\u306eASE\u7d50\u679c<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30ec\u30b8\u30f3\u306e\u6027\u72b6\u304c\u6d17\u6d44\u52b9\u7387\u306b\u4e0e\u3048\u308b\u5f71\u97ff<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">2\u56de\u76eeASE\u5f8c\u3067\u3042\u3063\u3066\u3082\u3001\u6bd4\u8f03\u7684\u9ad8\u6fc3\u5ea6\u306aPFAS\u304cXAD-2\u30ec\u30b8\u30f3\u3067\u306f\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u3002\u3057\u305f\u304c\u3063\u3066\u3001ASE\u306b\u3088\u308b\u62bd\u51fa\u52b9\u7387\u306fClean SDVB\u30ec\u30b8\u30f3\u306b\u6bd4\u3079\u3066\u52a3\u3063\u3066\u3044\u305f\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u305d\u306e\u8981\u56e0\u306e\u3072\u3068\u3064\u306f\u3001Clean SDVB\u30ec\u30b8\u30f3\u304c\u4e7e\u71e5\u3057\u3066\u304a\u308a\u30b5\u30e9\u30b5\u30e9\u3068\u6d41\u52d5\u6027\u304c\u9ad8\u304b\u3063\u305f\u306e\u306b\u5bfe\u3057\u3001XAD-2\u306f\u3084\u3084\u6e7f\u3063\u3066\u3044\u3066\u584a\u72b6\u306b\u306a\u3063\u3066\u3044\u305f\u3053\u3068\u3067\u3059\uff08Figure 1\u53c2\u7167\uff09\u3002\u3053\u306e\u300c\u6e7f\u308a\u6c17\u300d\u304cPFAS\u3092\u3088\u308a\u5f37\u304f\u4fdd\u6301\u3059\u308b\u539f\u56e0\u306b\u306a\u3063\u305f\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001\u3053\u306e\u72b6\u614b\u306eXAD-2\u306f\u4f5c\u696d\u6027\u306b\u3082\u5f71\u97ff\u3057\u3001Figure 1\u304b\u3089\u3082\u5206\u304b\u308b\u3088\u3046\u306b\u3001ASE\u30bb\u30eb\u3078\u306e\u5145\u586b\u4f5c\u696d\u3082\u3084\u3084\u7169\u96d1\u306b\u306a\u3063\u3066\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-4-otm-45-resin-cleaning-01.png\" alt=\"blog-PFAS-in-air-part-4-OTM-45-resin-cleaning-01.png\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 1 \u2013 Restek Clean SDVB\u30ec\u30b8\u30f3\u3068\u524d\u6d17\u6d44\u6e08XAD-2\u30ec\u30b8\u30f3\u306e\u6bd4\u8f03<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6539\u826f\u7248ASE\u624b\u6cd5\u306b\u3088\u308b\u6d17\u6d44\u52b9\u7387\u306e\u6700\u9069\u5316<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">NEMC\u3067\u306e\u767a\u8868\u5f8c\u3001Clean SDVB\u30ec\u30b8\u30f3\u304b\u3089PFAS\u3092\u5b8c\u5168\u306b\u9664\u53bb\u3067\u304d\u308b\u3001\u3088\u308a\u30b7\u30f3\u30d7\u30eb\u306aASE\u306b\u3088\u308b\u6d17\u6d44\u5c02\u7528\u624b\u6cd5\u3092\u78ba\u7acb\u3057\u305f\u3044\u3068\u8003\u3048\u308b\u3088\u3046\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u691c\u8a0e\u3092\u91cd\u306d\u305f\u7d50\u679c\u3001\u7d50\u5c40\u5909\u66f4\u3092\u52a0\u3048\u305f\u306e\u306f\u3088\u308a\u5f37\u529b\u306a\u6d17\u6d44\u52b9\u7387\u3092\u671f\u5f85\u3057\u3066\u3001\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3\uff08MeCl<sub>2<\/sub>\uff09\u3068\u30e1\u30bf\u30ce\u30fc\u30eb\u306e\u6df7\u5408\u6eb6\u5a92\u3092\u4f7f\u7528\u3059\u308b\u70b9\u3060\u3051\u3067\u3057\u305f\u3002\u3053\u306e\u6539\u826f\u624b\u6cd5\u306b\u304a\u3051\u308bASE\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u306f\u3001Table 4\u3092\u53c2\u7167\u4e0b\u3055\u3044\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">Dionex ASE 350\u30d1\u30e9\u30e1\u30fc\u30bf<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5727\u529b &#8211; 1500 psi<\/li>\n\n\n\n<li>\u6e29\u5ea6 &#8211; 120\u00b0 C<\/li>\n\n\n\n<li>\u52a0\u71b1\u6642\u9593 &#8211; 6\u5206<\/li>\n\n\n\n<li>\u9759\u6b62\u6642\u9593 &#8211; 15\u5206<\/li>\n\n\n\n<li>\u30b5\u30a4\u30af\u30eb &#8211; 2<\/li>\n\n\n\n<li>\u30ea\u30f3\u30b9\u91cf &#8211; 60%<\/li>\n\n\n\n<li>\u6eb6\u5a92 &#8211; 4:1 \u30e1\u30bf\u30ce\u30fc\u30eb:MeCl<sub>2<\/sub><\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Table 4 \u2013 Clean SDVB\u30ec\u30b8\u30f3\u306e\u6700\u7d42\u7684\u306aASE\u6d17\u6d44\u624b\u6cd5<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u6700\u7d42\u7684\u306aASE\u6d17\u6d44\u624b\u6cd5\u3092\u7528\u3044\u3066\u3082\u3001\u6b8b\u5ff5\u306a\u304c\u3089\u691c\u51fa\u4e0b\u9650\u3092\u308f\u305a\u304b\u306b\u8d85\u3048\u308b\u91cf\u306ePFDA\u304c\u6b8b\u3063\u3066\u3057\u307e\u3044\u307e\u3057\u305f\uff08\u3053\u306e\u9650\u754c\u306b\u81f3\u3063\u305f\u7d4c\u7def\u306b\u3064\u3044\u3066\u306f\u3001\u5f8c\u306e\u30d6\u30ed\u30b0\u3067\u8aac\u660e\u3057\u307e\u3059\uff09\u3002\u6d17\u6d44\u5f8c\u306e\u5168\u7d50\u679c\u306f\u3001Table 5\u306b\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table table table-bordered\"><table style=\"border-width:1px\"><tbody><tr><td>&nbsp;<\/td><td colspan=\"2\">ng PFAS\/g \u30ec\u30b8\u30f3<\/td><\/tr><tr><td><p>\u5316\u5408\u7269\u540d<\/p><\/td><td>\n<p>MDL<\/p>\n<\/td><td><p>\u30d6\u30e9\u30f3\u30afAvg.<\/p><\/td><\/tr><tr><td>\n<p>PFBA<\/p>\n<\/td><td>\n<p>0.06<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PF4OPeA<\/p>\n<\/td><td>\n<p>0.02<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>3:3 FTCA<\/p>\n<\/td><td>\n<p>0.05<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFPeA<\/p>\n<\/td><td>\n<p>0.03<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFBS<\/p>\n<\/td><td>\n<p>0.07<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PF5OHxA<\/p>\n<\/td><td>\n<p>0.01<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFEESA<\/p>\n<\/td><td>\n<p>0.01<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>3,6-OPFHpA<\/p>\n<\/td><td>\n<p>0.02<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>4-2 FTS<\/p>\n<\/td><td>\n<p>0.02<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFHxA<\/p>\n<\/td><td>\n<p>0.02<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFPeS<\/p>\n<\/td><td>\n<p>0.02<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>HFPO-DA<\/p>\n<\/td><td>\n<p>0.22<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFHpA<\/p>\n<\/td><td>\n<p>0.10<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>5:3 FTCA<\/p>\n<\/td><td>\n<p>0.07<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>FHUEA<\/p>\n<\/td><td>\n<p>0.06<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFHxS<\/p>\n<\/td><td>\n<p>0.06<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>FHEA<\/p>\n<\/td><td>\n<p>0.09<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>ADONA<\/p>\n<\/td><td>\n<p>0.02<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFeCHS<\/p>\n<\/td><td>\n<p>0.03<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>6-2 FTS<\/p>\n<\/td><td>\n<p>0.02<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFHpS<\/p>\n<\/td><td>\n<p>0.03<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFOA<\/p>\n<\/td><td>\n<p>0.22<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFOS<\/p>\n<\/td><td>\n<p>0.04<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>FOUEA<\/p>\n<\/td><td>\n<p>0.07<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFNA<\/p>\n<\/td><td>\n<p>0.06<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>FHpPA<\/p>\n<\/td><td>\n<p>0.14<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>FOEA<\/p>\n<\/td><td>\n<p>0.18<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>9Cl-PF3ONS<\/p>\n<\/td><td>\n<p>0.03<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>L-PFNS<\/p>\n<\/td><td>\n<p>0.18<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFDA<\/p>\n<\/td><td>\n<p>0.05<\/p>\n<\/td><td>\n<p>0.07<\/p>\n<\/td><\/tr><tr><td>\n<p>8-2 FTS<\/p>\n<\/td><td>\n<p>0.07<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>L-PFDS<\/p>\n<\/td><td>\n<p>0.32<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>FDEA<\/p>\n<\/td><td>\n<p>0.07<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFUnA<\/p>\n<\/td><td>\n<p>0.08<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>11Cl-PF3OUdS<\/p>\n<\/td><td>\n<p>0.04<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>FOSA-I<\/p>\n<\/td><td>\n<p>0.13<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>10:2 FTS<\/p>\n<\/td><td>\n<p>0.04<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFDoA<\/p>\n<\/td><td>\n<p>0.10<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFDoS<\/p>\n<\/td><td>\n<p>0.06<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>N-MeFOSA-M<\/p>\n<\/td><td>\n<p>0.07<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>N-MeFOSE<\/p>\n<\/td><td>\n<p>0.07<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>N-MeFOSAA<\/p>\n<\/td><td>\n<p>0.05<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFHxDA<\/p>\n<\/td><td>\n<p>0.05<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>N-EtFOSA-M<\/p>\n<\/td><td>\n<p>0.17<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>N-EtFOSE-M<\/p>\n<\/td><td>\n<p>0.05<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>N-EtFOSAA<\/p>\n<\/td><td>\n<p>0.08<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFODA<\/p>\n<\/td><td>\n<p>0.05<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFTrDA<\/p>\n<\/td><td>\n<p>0.08<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><tr><td>\n<p>PFTA<\/p>\n<\/td><td>\n<p>0.05<\/p>\n<\/td><td>\n<p>&lt;MDL<\/p>\n<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Table 5 \u2013 \u6d17\u6d44\u5f8cClean SDVB\u30ec\u30b8\u30f3\u306ePFAS\u30d6\u30e9\u30f3\u30af\u7d50\u679c<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u6700\u7d42\u6d17\u6d44\u7d50\u679c\u3068\u6b8b\u7559PFAS\u306e\u8003\u5bdf<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u521d\u56de\u306e\u6d17\u6d44\u5f8c\u306b\u78ba\u8a8d\u3055\u308c\u306a\u304b\u3063\u305fPFDA\u304c\u306a\u305c\u3053\u3053\u3067\u691c\u51fa\u3055\u308c\u305f\u306e\u3067\u3057\u3087\u3046\u304b\uff1f\u7d4c\u9a13\u4e0a\u3001\u3069\u3093\u306a\u30e9\u30dc\u306b\u304a\u3044\u3066\u3082PFAS\u5206\u6790\u306b\u304a\u3051\u308b\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\uff08\u6c5a\u67d3\uff09\u306f\u975e\u5e38\u306b\u4e88\u6e2c\u304c\u96e3\u3057\u3044\u3067\u3059\u3002\u4ee5\u524d\u306e\u30ed\u30c3\u30c8\u3067\u306fPFAS\u30d5\u30ea\u30fc\u3060\u3063\u305f\u6eb6\u5a92\u3084\u6d88\u8017\u54c1\u304c\u3001\u65b0\u3057\u3044\u30ed\u30c3\u30c8\u3067\u306fPFAS\u3092\u542b\u3093\u3067\u3044\u308b\u3053\u3068\u3082\u3042\u308b\u305f\u3081\u3001\u30d6\u30e9\u30f3\u30af\u30ec\u30d9\u30eb\u3092\u5e38\u306b\u76e3\u8996\u3059\u308b\u3079\u304d\u3067\u3059\u3002PFAS\u30d5\u30ea\u30fc\u306a\u30ef\u30fc\u30af\u30d5\u30ed\u30fc\u3092\u7dad\u6301\u3059\u308b\u306e\u306f\u3001\u307e\u308b\u3067\u5b9f\u9a13\u5ba4\u7248\u300c\u30e2\u30b0\u30e9\u53e9\u304d\u30b2\u30fc\u30e0\u300d\u306e\u3088\u3046\u306a\u3082\u306e\u2026\u3042\u308b\u65e5\u306f\u30dc\u30c8\u30eb\u304b\u3089PFBA\u304c\u51fa\u3066\u304d\u3066\u5bfe\u5fdc\u306b\u8ffd\u308f\u308c\u3001\u5225\u306e\u65e5\u306b\u306f\u6eb6\u5a92\u306b\u542b\u307e\u308c\u3066\u3044\u305fPFBS\u3092\u53e9\u304d\u306b\u884c\u304f\u3002\u3053\u306e\u3088\u3046\u306a\u72b6\u6cc1\u304c\u5e38\u3067\u3059\u304b\u3089\u300149\u7a2e\u985e\u4e2d1\u5316\u5408\u7269\u306e\u307f\u304c\u308f\u305a\u304b\u306b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u3068\u3057\u3066\u691c\u51fa\u3055\u308c\u305f\u3060\u3051\u306a\u3089\u3001\u3082\u3046\u6b21\u306e\u30b9\u30c6\u30c3\u30d7\u3067\u3042\u308b\u62bd\u51fa\u8a66\u9a13\u306b\u9032\u3093\u3067\u3082\u3088\u3044\u3060\u308d\u3046\u3068\u5224\u65ad\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u62bd\u51fa\u8a66\u9a13\u306b\u3064\u3044\u3066\u306f\u6b21\u56de\u306e\u30d6\u30ed\u30b0\u3067\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002OTM-45\u3067\u6307\u5b9a\u3055\u308c\u3066\u3044\u308b\u632f\u3068\u3046\u62bd\u51fa\u3068ASE\u306b\u3088\u308b\u62bd\u51fa\u3068\u306e\u6bd4\u8f03\u3092\u884c\u3046\u4e88\u5b9a\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4767-ja\/pfas-in-air-part-1-otm-45-japan\">\uff1c\u7b2c1\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u6982\u8981<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4768-ja\/pfas-in-air-part-2-otm-45-japan\">\uff1c\u7b2c2\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306b\u57fa\u3065\u3044\u305f\u6700\u9069\u5316<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4769-ja\/pfas-in-air-part-3-otm-45-calibrations-japan\">\uff1c\u7b2c3\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u6821\u6b63<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4771-ja\/pfas-in-air-part-5-resin-extraction-japan\">\uff1c\u7b2c5\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30ec\u30b8\u30f3\u62bd\u51fa<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>EPA\u304c\u767a\u8868\u3057\u305fPFAS\u6392\u30ac\u30b9\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3068\u5206\u6790\u306e\u30e1\u30bd\u30c3\u30c9OTM-45\u3092\u89e3\u8aac\u3002\u56fa\u5b9a\u767a\u751f\u6e90PFAS\u691c\u67fb\u306b\u5fc5\u8981\u306a\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u624b\u9806\u3084LC-MS\/MS\u5206\u6790\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u521d\u5fc3\u8005\u306b\u3082\u308f\u304b\u308a\u3084\u3059\u304f\u7d39\u4ecb\u3057\u307e\u3059\u3002\u7b2c4\u56de\u306fOTM-45\u306b\u6e96\u62e0\u3057\u305f\u30ec\u30b8\u30f3\u6d17\u6d44\u624b\u9806\u3092\u5fb9\u5e95\u89e3\u8aac\u3002Dionex ASE 350\u3092\u7528\u3044\u305fPFAS\u9664\u53bb\u306e\u52b9\u679c\u3084\u3001Clean SDVB\u3068XAD-2\u306e\u6bd4\u8f03\u7d50\u679c\u3001\u52b9\u7387\u7684\u306a\u6d17\u6d44\u30e1\u30bd\u30c3\u30c9\u3092\u7d39\u4ecb\u3002<\/p>\n","protected":false},"author":27,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[819],"tags":[2760],"industries-application":[2288,2272,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2339],"ppma_author":[447],"class_list":["post-71508","post","type-post","status-publish","format-standard","hentry","category-press-releases-news-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-air-monitoring-ja","industries-application-environmental-ja","resource-technique-air-sampling-ja"],"acf":[],"taxonomy_info":{"category":[{"value":819,"label":"\u30cb\u30e5\u30fc\u30b9\u30ea\u30ea\u30fc\u30b9"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2272,"label":"\u5927\u6c17 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2339,"label":"\u30a8\u30a2\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jason Hoisington","author_link":"https:\/\/discover.restek.com\/ja\/author\/jason-hoisington\/"},"comment_info":0,"category_info":[{"term_id":819,"name":"\u30cb\u30e5\u30fc\u30b9\u30ea\u30ea\u30fc\u30b9","slug":"press-releases-news-ja","term_group":0,"term_taxonomy_id":819,"taxonomy":"category","description":"","parent":0,"count":72,"filter":"raw","cat_ID":819,"category_count":72,"category_description":"","cat_name":"\u30cb\u30e5\u30fc\u30b9\u30ea\u30ea\u30fc\u30b9","category_nicename":"press-releases-news-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":447,"user_id":27,"is_guest":0,"slug":"jason-hoisington","display_name":"Jason Hoisington","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg"},"author_category":"1","first_name":"Jason","last_name":"Hoisington","user_url":"https:\/\/www.linkedin.com\/in\/jason-hoisington-73067653\/","job_title":"Principal Scientist, Sample Preparation","description":"Jason Hoisington received his bachelor\u2019s degree in general science with a focus on chemistry from the University of Alaska, Fairbanks. He worked for SGS Environmental for seven years in environmental soil and water testing, developing methods for the analysis of volatiles and semivolatile organics to include pesticides and polychlorinated biphenyls (PCBs). In 2012, Jason moved on to lab and application support for Dow Chemical Company, providing advanced analytical troubleshooting and method development. In 2019, Jason joined Restek and has focused on air applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71508","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71508"}],"version-history":[{"count":4,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71508\/revisions"}],"predecessor-version":[{"id":93984,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71508\/revisions\/93984"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71508"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71508"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71508"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71508"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71508"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71508"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71508"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71508"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71508"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}