{"id":71513,"date":"2022-08-13T14:30:00","date_gmt":"2022-08-13T14:30:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71513"},"modified":"2026-09-25T14:22:54","modified_gmt":"2026-09-25T14:22:54","slug":"pfas-in-air-part-5-resin-extraction-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4771-ja\/pfas-in-air-part-5-resin-extraction-japan","title":{"rendered":"PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u7b2c5\u56de\uff1a\u30ec\u30b8\u30f3\u62bd\u51fa"},"content":{"rendered":"\n<p class=\"wp-block-paragraph\">\u6700\u7d42\u66f4\u65b0\u65e5\uff1a2025\u5e7410\u670810\u65e5<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">OTM-45\u306b\u304a\u3051\u308b\u62bd\u51fa\u5de5\u7a0b\u306e\u307e\u3068\u3081<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4eca\u56de\u306f\u30b7\u30ea\u30fc\u30ba\u306e\u6700\u7d42\u56de\u3067\u3059\u3002\u7b2c1\u56de\u3067\u306f\u30c9\u30e9\u30d5\u30c8\u7248OTM-45 Method\u306e\u6982\u8981\u3001\u7b2c2\u56de\u3067\u306f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306b\u57fa\u3065\u304f\u6700\u9069\u5316\u3001\u7b2c3\u56de\u3067\u306f\u6821\u6b63\u8981\u4ef6\u3068\u7d50\u679c\u3001\u7b2c4\u56de\u3067\u306f\u30ec\u30b8\u30f3\u6d17\u6d44\u624b\u6cd5\u306b\u3064\u3044\u3066\u8aac\u660e\u3057\u307e\u3057\u305f\u3002\u4eca\u56de\u306f\u3001OTM-45\u304c\u30ab\u30d0\u30fc\u3059\u308b\u632f\u3068\u3046\u62bd\u51fa\u306e\u4ee3\u66ff\u3068\u3057\u3066\u4f7f\u7528\u3057\u305f\u9ad8\u901f\u6eb6\u5a92\u62bd\u51fa\uff08ASE\uff09\u306b\u3064\u3044\u3066\u3055\u3089\u306b\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u632f\u3068\u3046\u62bd\u51fa\u306e\u624b\u9806\u3068\u4f7f\u7528\u6eb6\u5a92\u91cf<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30dd\u30ea\u30a6\u30ec\u30bf\u30f3\u30d5\u30a9\u30fc\u30e0\uff08PUF\uff09\u3084XAD-2\u30bf\u30a4\u30d7\u306e\u30b9\u30c1\u30ec\u30f3-\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\uff08SDVB\uff09\u30ec\u30b8\u30f3\u306a\u3069\u306e\u5145\u586b\u5264\u3092\u4f7f\u7528\u3059\u308b\u30a8\u30a2\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u6cd5\u3067\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u306b\u306f<strong>\u30bd\u30c3\u30af\u30b9\u30ec\u30fc\u62bd\u51fa<\/strong>\u304c\u3088\u304f\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u30bd\u30c3\u30af\u30b9\u30ec\u30fc\u62bd\u51fa\u3068\u306f\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3092\u56fa\u5f62\u7269\u304b\u3089\u62bd\u51fa\u3059\u308b\u305f\u3081\u306b\u3001\u52a0\u71b1\u3057\u305f\u6eb6\u5a92\u3092\u9023\u7d9a\u7684\u306b\u9084\u6d41\u3055\u305b\u306a\u304c\u3089\u56fa\u4f53\u3092\u6d17\u3044\u6d41\u3059\u65b9\u6cd5\u3067\u3059\u3002\u4e00\u822c\u7684\u306b\u9577\u6642\u9593\u304b\u3051\u3066\u884c\u308f\u308c\u3001\u4f8b\u3048\u3070\u3001TO-13A\u3067\u306f<strong>18\u6642\u9593<\/strong>\u306e\u62bd\u51fa\u304c\u5fc5\u8981\u3067\u3059\u3002\u4e00\u65b9\u3001OTM-45\u3067\u306f\u3053\u308c\u3088\u308a\u3082\u7c21\u4fbf\u306a\u65b9\u6cd5\u3068\u3057\u3066\u3001\u62bd\u51fa\u6eb6\u5a92\u4e2d\u3067\u8a66\u6599\u3092\u632f\u3068\u3046\u3059\u308b\u3060\u3051\u306e<strong>\u632f\u3068\u3046\u62bd\u51fa<\/strong>\u304c\u63a1\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u65b9\u6cd5\u306f\u3001\u7279\u6b8a\u306a\u30ac\u30e9\u30b9\u5668\u5177\u3084\u52a0\u71b1\u88c5\u7f6e\u3092\u5fc5\u8981\u3068\u305b\u305a\u3001\u3088\u308a\u30b7\u30f3\u30d7\u30eb\u306a\u30bb\u30c3\u30c8\u30a2\u30c3\u30d7\u3067\u5b9f\u65bd\u53ef\u80fd\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u62bd\u51fa\u52b9\u7387\u306f\u30bd\u30c3\u30af\u30b9\u30ec\u30fc\u62bd\u51fa\u3088\u308a\u52a3\u308b\u3068\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3001OTM-45\u3067\u306f\u3053\u306e\u52b9\u7387\u306e\u5dee\u3092\u88dc\u3046\u3079\u304f\u300116\u6642\u9593\u00d72\u56de\uff1d\u5408\u8a08<strong>32\u6642\u9593<\/strong>\u306e\u9577\u6642\u9593\u632f\u3068\u3046\u304c\u5b9f\u884c\u3055\u308c\u307e\u3059\u3002\u5404\u632f\u3068\u3046\u3067\u306f\u30015%\u30a2\u30f3\u30e2\u30cb\u30a2\u6c34\u30e1\u30bf\u30ce\u30fc\u30eb\u6eb6\u6db2\u3092180 mL\u305a\u3064\u3001\u5408\u8a08360 mL\u304c\u4f7f\u7528\u3055\u308c\u307e\u3059\u3002\u6700\u521d\u306eXAD\u30c8\u30e9\u30c3\u30d7\uff08Figure 1\u306e\u5bb9\u5668#3\uff09\u306e\u62bd\u51fa\u306b\u306f\u3001\u7c92\u5b50\u30d5\u30a3\u30eb\u30bf\u30fc\u3068XAD\u30c8\u30e9\u30c3\u30d7\u9593\u306e\u8a66\u6599\u63a1\u53d6\u7cfb\u3092\u6d17\u6d44\u3059\u308b\u305f\u3081\u306e<strong>\u5f8c\u534a\u30ea\u30f3\u30b9\u6db2<\/strong>\uff08Figure 1\u306e\u5bb9\u5668#4\uff09\u3092\u305d\u306e\u307e\u307e\u5229\u7528\u3057\u307e\u3059\u3002\u3082\u3057\u3053\u306e\u5f8c\u534a\u30ea\u30f3\u30b9\u6db2\u306e\u91cf\u304c360 mL\u306b\u6e80\u305f\u306a\u3044\u5834\u5408\u306f\u3001\u4e0d\u8db3\u5206\u3092\u8ffd\u52a0\u306e\u30a2\u30f3\u30e2\u30cb\u30a2\u6c34\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u88dc\u3044\u307e\u3059\u3002\u4e00\u65b9\u3001\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fcXAD\u30c8\u30e9\u30c3\u30d7\uff08Figure 1\u306e\u5bb9\u5668#7\uff09\u306f\u3001\u30a2\u30f3\u30e2\u30cb\u30a2\u6c34\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u62bd\u51fa\u3055\u308c\u308b\u3082\u306e\u306e\u3001\u3053\u3061\u3089\u306b\u306f\u8a66\u6599\u63a1\u53d6\u7cfb\u306e\u6d17\u6d44\u306b\u306f\u4f7f\u7528\u3055\u308c\u307e\u305b\u3093\u3002\u3064\u307e\u308a\u3001\u8a66\u6599\u63a1\u53d6\u7cfb\u3067\u306e\u30ec\u30b8\u30f3\u62bd\u51fa\u306b\u306f\u6700\u4f4e\u3067\u3082360 mL\u306e<strong>\u975e\u30ea\u30f3\u30b9\u6eb6\u5a92<\/strong>\u304c\u4f7f\u7528\u3055\u308c\u3001\u5168\u4f53\u3067<strong>720 mL\u306e\u6eb6\u5a92<\/strong>\u304c\u6d88\u8cbb\u3055\u308c\u308b\u3068\u3044\u3046\u3053\u3068\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"681\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-5-resin-extraction-01-1024x681.png\" alt=\"\" class=\"wp-image-16534\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-5-resin-extraction-01-1024x681.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-5-resin-extraction-01-300x200.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-5-resin-extraction-01-768x511.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-5-resin-extraction-01-1536x1022.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-5-resin-extraction-01.png 1960w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 1 \u2013 OTM-45\u8a66\u6599\u63a1\u53d6\u7cfb\u3068\u5bb9\u5668<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u9ad8\u901f\u6eb6\u5a92\u62bd\u51fa\uff08ASE\uff09\u306e\u5c0e\u5165\u3068\u30e1\u30ea\u30c3\u30c8<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0a\u8a18\u306e\u3088\u3046\u306a\u6642\u9593\u304c\u304b\u304b\u308a\u3001\u591a\u304f\u306e\u6eb6\u5a92\u304c\u5fc5\u8981\u306a\u632f\u3068\u3046\u62bd\u51fa\u3068\u6bd4\u3079\u3001ASE\u306b\u306f\u591a\u304f\u306e\u5229\u70b9\u304c\u3042\u308a\u307e\u3059\u3002ASE\u3067\u306f\u3001\u52a0\u71b1\u3057\u305f\u6eb6\u5a92\u3092\u9ad8\u5727\u4e0b\u3067\u4f7f\u7528\u3057\u307e\u3059\u304c\u3001\u3053\u308c\u306b\u3088\u308a\u77ed\u6642\u9593\u304b\u3064\u9ad8\u52b9\u7387\u306a\u62bd\u51fa\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002ASE\u306b\u3088\u308b\u30b5\u30f3\u30d7\u30eb\u62bd\u51fa\u3067\u5fc5\u8981\u306a\u6240\u8981\u6642\u9593\u306f<strong>45\u5206<\/strong>\u3001\u4f7f\u7528\u3059\u308b\u6eb6\u5a92\u306f<strong>100 mL\u672a\u6e80<\/strong>\u3067\u3059\u3002\u3053\u308c\u306f\u3001\u632f\u3068\u3046\u62bd\u51fa\uff08\u6240\u8981\u6642\u9593<strong>32\u6642\u9593<\/strong>\u3001\u4f7f\u7528\u6eb6\u5a92<strong>360 mL<\/strong>\uff09\u3068\u6bd4\u8f03\u3057\u3066\u5927\u5e45\u306a\u52b9\u7387\u6539\u5584\u3068\u306a\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001ASE\u3067\u306f\u3001\u6eb6\u5a92\u30ea\u30b6\u30fc\u30d0\u30fc\u306f\u3059\u3079\u3066\u306e\u30b5\u30f3\u30d7\u30eb\u306b\u5171\u901a\u3067\u4f7f\u7528\u3055\u308c\u308b\u305f\u3081\u3001\u5f8c\u534a\u30ea\u30f3\u30b9\u6db2\uff08\u5bb9\u5668#4\uff09\u3092\u305d\u306e\u307e\u307e\u62bd\u51fa\u6eb6\u5a92\u3068\u3057\u3066\u4f7f\u3046\u3053\u3068\u306f\u3067\u304d\u307e\u305b\u3093\u3002\u305d\u306e\u305f\u3081\u3001\u5f8c\u534a\u30ea\u30f3\u30b9\u6db2\u306f\u62bd\u51fa\u5f8c\u306e\u30d6\u30ed\u30fc\u30c0\u30a6\u30f3\u5de5\u7a0b\u3067ASE\u62bd\u51fa\u6eb6\u5a92\u3068\u5408\u308f\u305b\u3066\u51e6\u7406\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u4e21\u65b9\u306e\u30ec\u30b8\u30f3\u753b\u5206\uff08\u5bb9\u5668#3\u304a\u3088\u3073#7\uff09\u306b\u5bfe\u3057\u3066ASE\u306b\u304a\u3044\u3066\u4f7f\u7528\u3055\u308c\u308b<strong>\u975e\u30ea\u30f3\u30b9\u6eb6\u5a92<\/strong>\u306f<strong>200 mL<\/strong>\u3067\u3042\u308a\u3001\u632f\u3068\u3046\u62bd\u51fa\u306b\u304a\u3051\u308b<strong>360 mL<\/strong>\u3068\u6bd4\u3079\u3066\u5927\u5e45\u306b\u524a\u6e1b\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u7dcf\u6eb6\u5a92\u4f7f\u7528\u91cf\u306b\u95a2\u3057\u3066\u3082\u3001<strong>ASE<\/strong>\u3067\u306f<strong>560 mL<\/strong>\uff08\u30ea\u30f3\u30b9\u6eb6\u5a92360 mL\uff0b\u62bd\u51fa\u6eb6\u5a92200 mL\uff09\u3067\u6e08\u307f\u307e\u3059\u304c\u3001<strong>\u632f\u3068\u3046\u62bd\u51fa<\/strong>\u3067\u306f\u5408\u8a08<strong>720 mL<\/strong>\u304c\u5fc5\u8981\u3067\u3059\u3002\u4f7f\u7528\u3057\u305fASE\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u306fTable 1\u306b\u793a\u3057\u307e\u3057\u305f\u3002\u30e1\u30bf\u30ce\u30fc\u30eb:\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb\uff08ACN\uff094:1\u306e\u6df7\u5408\u6db2\u3092\u62bd\u51fa\u6eb6\u5a92\u3068\u3057\u3066\u4f7f\u7528\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u5358\u72ec\u3067\u306f\u5168\u4f53\u7684\u306b\u56de\u53ce\u7387\u304c\u4f4e\u304f\uff08\u30c7\u30fc\u30bf\u672a\u63b2\u8f09\uff09\u3001ACN\u3092\u591a\u304f\u3057\u3059\u304e\u308b\u3068\u4e00\u90e8\u5316\u5408\u7269\u3067\u56de\u53ce\u7387\u304c\u60aa\u5316\u3057\u305f\uff08\u30c7\u30fc\u30bf\u672a\u63b2\u8f09\uff09\u305f\u3081\u3067\u3059\u3002<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Dionex ASE 350\u62bd\u51fa\u30d1\u30e9\u30e1\u30fc\u30bf<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u5727\u529b \u2014 1500 psi<\/li>\n\n\n\n<li>\u6e29\u5ea6 \u2014 120\u00b0C<\/li>\n\n\n\n<li>\u52a0\u71b1\u6642\u9593 \u2014 6 minutes<\/li>\n\n\n\n<li>\u9759\u6b62\u6642\u9593\u2014 15 minutes<\/li>\n\n\n\n<li>\u30b5\u30a4\u30af\u30eb \u2014 2<\/li>\n\n\n\n<li>\u30ea\u30f3\u30b9\u91cf \u2014 60%<\/li>\n\n\n\n<li>\u6eb6\u5a92 \u2014 4:1 \u30e1\u30bf\u30ce\u30fc\u30eb:\u30a2\u30bb\u30c8\u30cb\u30c8\u30ea\u30eb<\/li>\n<\/ul>\n\n\n\n<p class=\"wp-block-paragraph\">Table 1 \u2013 ASE\u62bd\u51fa\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">ASE\u3068\u632f\u3068\u3046\u62bd\u51fa\u306e\u62bd\u51fa\u52b9\u7387\u306e\u6bd4\u8f03<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u3053\u306e\u3088\u3046\u306bASE\u3067\u306f\u62bd\u51fa\u6642\u9593\u3084\u6eb6\u5a92\u4f7f\u7528\u91cf\u304c\u6539\u5584\u3055\u308c\u307e\u3057\u305f\u3002\u305f\u3060\u3057\u3001\u62bd\u51fa\u305d\u306e\u3082\u306e\u306e\u6027\u80fd\u304c\u632f\u3068\u3046\u62bd\u51fa\u3068\u540c\u7b49\u307e\u305f\u306f\u305d\u308c\u4ee5\u4e0a\u3067\u306a\u3051\u308c\u3070\u610f\u5473\u304c\u3042\u308a\u307e\u305b\u3093\u3002ASE\u3068\u632f\u3068\u3046\u62bd\u51fa\u3068\u306e\u6027\u80fd\u306b\u304a\u3051\u308b\u6700\u3082\u9855\u8457\u306a\u9055\u3044\u3092\u3001\u300c\u751f\u30c7\u30fc\u30bf\uff08\u30d4\u30fc\u30af\u9762\u7a4d\u5024\uff09\u300d\u3067\u78ba\u8a8d\u3057\u3066\u307f\u307e\u3057\u3087\u3046\uff08Figure 2\u53c2\u7167\uff09\u3002ASE\u3067\u5f97\u3089\u308c\u305f\u30d4\u30fc\u30af\u9762\u7a4d\u306f\u632f\u3068\u3046\u62bd\u51fa\u3067\u5f97\u3089\u308c\u305f\u30d4\u30fc\u30af\u9762\u7a4d\u306e142%\u304b\u3089\u6700\u59275495%\u306b\u307e\u3067\u53ca\u3073\u3001\u307b\u3068\u3093\u3069\u306e\u5316\u5408\u7269\u3067\u306f200\u301c500%\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002\u3064\u307e\u308a\u3001\u30ec\u30b8\u30f3\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u304b\u3089\u62bd\u51fa\u3055\u308c\u305fPFAS\u306e\u307b\u3068\u3093\u3069\u306f\u3001\u632f\u3068\u3046\u62bd\u51fa\u3088\u308a\u3082ASE\u306e\u65b9\u304c2\uff5e5\u500d\u62bd\u51fa\u52b9\u7387\u304c\u9ad8\u304b\u3063\u305f\u3068\u3044\u3046\u3053\u3068\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-5-resin-extraction-02.png\" alt=\"blog-PFAS-in-air-part-5-resin-extraction-02.png\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 2 \u2013 ASE\uff1a\u632f\u3068\u3046\u62bd\u51fa&nbsp;&nbsp;\u62bd\u51fa\u52b9\u7387\uff08\u30d4\u30fc\u30af\u9762\u7a4d\uff09\u306e\u6bd4\u7387<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u30b9\u30d1\u30a4\u30af\u56de\u53ce\u7387\u306b\u898b\u308b\u6027\u80fd\u5dee<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u307b\u3068\u3093\u3069\u306e\u5316\u5408\u7269\u306b\u304a\u3044\u3066\u3001ASE\u306b\u3088\u308b\u62bd\u51fa\u52b9\u7387\u306e\u65b9\u304c\u512a\u308c\u3066\u3044\u307e\u3057\u305f\u304c\u3001\u540c\u4f4d\u4f53\u5e0c\u91c8\u6cd5\u3092\u4f7f\u7528\u3057\u305f\u3053\u3068\u306b\u3088\u308a\u3001\u632f\u3068\u3046\u62bd\u51fa\u3068ASE\u306e\u56de\u53ce\u7387\u306e\u5dee\u306f\u4e00\u898b\u540c\u3058\u3088\u3046\u306b\u3082\u898b\u3048\u3066\u3044\u307e\u3059\u3002\u305d\u308c\u305e\u308c\u306e\u62bd\u51fa\u7d50\u679c\u306fFigure 3\u306b\u793a\u3057\u305f\u901a\u308a\u3067\u3059\uff08\u9752\u304cASE\u3001\u8d64\u304c\u632f\u3068\u3046\u62bd\u51fa\uff09\u3002\u7279\u306b\u56de\u53ce\u7387\u304c\u6975\u7aef\u306b\u9ad8\u3044\u3001\u307e\u305f\u306f\u4f4e\u3044\u5916\u308c\u5024\u3068\u306a\u3063\u305f\u4e00\u90e8\u306e\u5316\u5408\u7269\u306b\u306f\u3001\u540c\u4f4d\u4f53\u6a19\u6e96\u7269\u8cea\u304c\u5b58\u5728\u3057\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3068\u5185\u90e8\u6a19\u6e96\u7269\u8cea\u3068\u306e\u62bd\u51fa\u52b9\u7387\u306e\u5dee\u304c\u88dc\u6b63\u3057\u5207\u308c\u3066\u3044\u307e\u305b\u3093\u3002\u3053\u308c\u304c\u7cbe\u5ea6\u4f4e\u4e0b\u306e\u8981\u56e0\u306b\u306a\u3063\u305f\u3068\u8003\u3048\u3089\u308c\u307e\u3059\u3002\u3068\u306f\u3044\u3048\u3001ASE\u306b\u3088\u308b\u62bd\u51fa\u52b9\u7387\u304c\u9ad8\u3044\u3053\u3068\u3067\u3001\u632f\u3068\u3046\u62bd\u51fa\u3067\u306f\u56de\u53ce\u7387\u304c\u4f4e\u304b\u3063\u305f3:3 FTCA\u3084Me-FOSA\u3001Et-FOSA\u3068\u3044\u3063\u305f\u5316\u5408\u7269\u3082\u3001ASE\u3067\u306f\u56de\u53ce\u7387\u304c\u5927\u5e45\u306b\u6539\u5584\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-5-resin-extraction-03.png\" alt=\"blog-PFAS-in-air-part-5-resin-extraction-03.png\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 3 \u2013 ASE\u3068\u632f\u3068\u3046\u62bd\u51fa\u306e\u30b9\u30d1\u30a4\u30af\u56de\u53ce\u7387<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u518d\u73fe\u6027\u8a55\u4fa1\uff1aASE\u306e\u512a\u4f4d\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u518d\u73fe\u6027\u306b\u95a2\u3057\u3066\u3082\u3001ASE\u306b\u3088\u308b\u62bd\u51fa\u306f\u632f\u3068\u3046\u62bd\u51fa\u3092\u4e0a\u56de\u308b\u7d50\u679c\u3092\u793a\u3057\u307e\u3057\u305f\u300249\u5316\u5408\u7269\u306e\u3046\u306140\u5316\u5408\u7269\u304c\u898f\u5b9a\u306e\u57fa\u6e96\u3092\u6e80\u305f\u3057\u307e\u3057\u305f\u304c\u3001\u57fa\u6e96\u672a\u9054\u3068\u306a\u3063\u305f\u5316\u5408\u7269\u306e\u591a\u304f\u306f\u3001\u5bfe\u5fdc\u3059\u308b\u6b63\u78ba\u306a\u540c\u4f4d\u4f53\u5e0c\u91c8\u6a19\u6e96\u7269\u8cea\u304c\u5b58\u5728\u3057\u306a\u304b\u3063\u305f\u3082\u306e\u3067\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u540c\u4f4d\u4f53\u5e0c\u91c8\u6a19\u6e96\u7269\u8cea\u306e\u9078\u5b9a\u3092\u6539\u5584\u3059\u308c\u3070\u3001\u7d50\u679c\u3082\u3055\u3089\u306b\u6539\u5584\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u307e\u305f\u3001Figure 4\u306b\u793a\u3059\u3088\u3046\u306b\u3001\u5f8c\u671f\u306b\u6eb6\u51fa\u3059\u308b\u5316\u5408\u7269\u307b\u3069\u3001\u632f\u3068\u3046\u62bd\u51fa\u3067\u306e\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\uff08% RSD\uff09\u304cASE\u306b\u6bd4\u3079\u3066\u304b\u306a\u308a\u9ad8\u304f\u306a\u308b\uff08\u3070\u3089\u3064\u304d\u304c\u591a\u304f\u306a\u308b\uff09\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u632f\u3068\u3046\u62bd\u51fa\u304c\u9577\u9396PFAS\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u62bd\u51fa\u306e\u4e00\u8cab\u6027\u3092\u4fdd\u3064\u306e\u304c\u96e3\u3057\u3044\u53ef\u80fd\u6027\u3092\u793a\u5506\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/blog-pfas-in-air-part-5-resin-extraction-04.png\" alt=\"blog-PFAS-in-air-part-5-resin-extraction-04.png\" title=\"-\"><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">Figure 4 &#8211; ASE\u3068\u632f\u3068\u3046\u62bd\u51fa\u306e\u76f8\u5bfe\u6a19\u6e96\u504f\u5dee\uff08%RSD\uff09<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">ASE\u306b\u3088\u308b\u62bd\u51fa\u306f\u3001OTM\u201145\u3067\u898f\u5b9a\u3055\u308c\u3066\u3044\u308b\u632f\u3068\u3046\u62bd\u51fa\u306e\u4ee3\u66ff\u624b\u6cd5\u3068\u3057\u3066\u6975\u3081\u3066\u6709\u52b9\u3067\u3042\u308b\u3053\u3068\u304c\u660e\u3089\u304b\u306b\u306a\u308a\u307e\u3057\u305f\u3002\u6642\u9593\u77ed\u7e2e\u3068\u6eb6\u5a92\u4f7f\u7528\u91cf\u306e\u524a\u6e1b\u3092\u540c\u6642\u306b\u5b9f\u73fe\u3057\u3064\u3064\u3001\u62bd\u51fa\u7d50\u679c\u5168\u4f53\u3067\u3082\u826f\u597d\u306a\u6210\u679c\u3092\u793a\u3059\u624b\u6cd5\u3067\u3042\u308b\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4767-ja\/pfas-in-air-part-1-otm-45-japan\">\uff1c\u7b2c1\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u6982\u8981<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4768-ja\/pfas-in-air-part-2-otm-45-japan\">\uff1c\u7b2c2\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u306b\u57fa\u3065\u3044\u305f\u6700\u9069\u5316<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl4769-ja\/pfas-in-air-part-3-otm-45-calibrations-japan\">\uff1c\u7b2c3\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u6821\u6b63<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/press-releases-news-ja\/gnbl4770-ja\/pfas-in-air-part-4-otm-45-resin-cleaning-japan\">\uff1c\u7b2c4\u56de\uff1e\u3000PFAS\u6392\u30ac\u30b9\u5206\u6790\u306e\u57fa\u6e96 OTM-45\u3000\u30ec\u30b8\u30f3\u6d17\u6d44<\/a><\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u51685\u56de\u30b7\u30ea\u30fc\u30ba\u306e\u30d6\u30ed\u30b0\u3092\u901a\u3057\u3066\u3001OTM-45\u3078\u306e\u7406\u89e3\u306f\u6df1\u307e\u308a\u307e\u3057\u305f\u3067\u3057\u3087\u3046\u304b\uff1f\u30e1\u30bd\u30c3\u30c9\u304c\u5909\u308f\u3063\u3066\u3082\u3001\u5206\u6790\u4e2d\u306e\u8e93\u304d\u306e\u969b\u306b\u30d2\u30f3\u30c8\u306b\u306a\u308b\u3088\u3046\u306a\u30a2\u30a4\u30c7\u30a2\u3082\u3042\u3063\u305f\u306e\u3067\u306f\u306a\u3044\u304b\u3068\u601d\u3044\u307e\u3059\u3002\u3054\u611f\u60f3\u3084\u3054\u8cea\u554f\u3001\u3053\u3093\u306a\u4e8b\u3092\u3082\u3063\u3068\u77e5\u308a\u305f\u3044\uff01\u7b49\u306b\u3064\u3044\u3066\u306f\u662f\u975e<a href=\"https:\/\/www.restek.com\/global\/ja\/contact-us\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089<\/a>\u307e\u3067\u304a\u5bc4\u305b\u304f\u3060\u3055\u3044\u3002Restek\u3067\u306f\u3001\u3088\u308a\u826f\u3044\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u3092\u5f97\u308b\u305f\u3081\u306bRestek\u306e\u6280\u8853\u304c\u30b5\u30dd\u30fc\u30c8\u3067\u304d\u308b\u3053\u3068\u3092\u5e38\u306b\u63a2\u6c42\u3057\u3066\u3044\u307e\u3059\uff01<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>EPA\u304c\u767a\u8868\u3057\u305fPFAS\u6392\u30ac\u30b9\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u3068\u5206\u6790\u306e\u30e1\u30bd\u30c3\u30c9OTM-45\u3092\u89e3\u8aac\u3002\u56fa\u5b9a\u767a\u751f\u6e90PFAS\u691c\u67fb\u306b\u5fc5\u8981\u306a\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u624b\u9806\u3084LC-MS\/MS\u5206\u6790\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u521d\u5fc3\u8005\u306b\u3082\u308f\u304b\u308a\u3084\u3059\u304f\u7d39\u4ecb\u3057\u307e\u3059\u3002\u7b2c5\u56de\u306fOTM-45\u306b\u304a\u3051\u308b\u5f93\u6765\u306e\u632f\u3068\u3046\u62bd\u51fa\u306b\u4ee3\u308f\u308b\u624b\u6cd5\u3068\u3057\u3066\u3001\u9ad8\u901f\u6eb6\u5a92\u62bd\u51fa\uff08ASE\uff09\u306e\u5c0e\u5165\u52b9\u679c\u3092\u89e3\u8aac\u3002\u62bd\u51fa\u52b9\u7387\u30fb\u6642\u9593\u30fb\u6eb6\u5a92\u4f7f\u7528\u91cf\u3092\u5927\u5e45\u306b\u6539\u5584\u3057\u3001PFAS\u5206\u6790\u306b\u304a\u3051\u308b\u524d\u51e6\u7406\u306e\u52b9\u7387\u5316\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":27,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[794],"tags":[2760],"industries-application":[2288,2272,2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2339],"ppma_author":[447],"class_list":["post-71513","post","type-post","status-publish","format-standard","hentry","category-blogs-ja","tag-pfas","industries-application-pfas-testing-ja","industries-application-air-monitoring-ja","industries-application-environmental-ja","resource-technique-air-sampling-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"post_tag":[{"value":2760,"label":"PFAS"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2272,"label":"\u5927\u6c17 \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}],"resource-technique":[{"value":2339,"label":"\u30a8\u30a2\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0"}]},"featured_image_src_large":false,"author_info":{"display_name":"Jason Hoisington","author_link":"https:\/\/discover.restek.com\/ja\/author\/jason-hoisington\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":457,"filter":"raw","cat_ID":794,"category_count":457,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":[{"term_id":2760,"name":"PFAS","slug":"pfas","term_group":0,"term_taxonomy_id":2760,"taxonomy":"post_tag","description":"","parent":0,"count":51,"filter":"raw"}],"authors":[{"term_id":447,"user_id":27,"is_guest":0,"slug":"jason-hoisington","display_name":"Jason Hoisington","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-hoisington-jason-01.jpg"},"author_category":"1","first_name":"Jason","last_name":"Hoisington","user_url":"https:\/\/www.linkedin.com\/in\/jason-hoisington-73067653\/","job_title":"Principal Scientist, Sample Preparation","description":"Jason Hoisington received his bachelor\u2019s degree in general science with a focus on chemistry from the University of Alaska, Fairbanks. He worked for SGS Environmental for seven years in environmental soil and water testing, developing methods for the analysis of volatiles and semivolatile organics to include pesticides and polychlorinated biphenyls (PCBs). In 2012, Jason moved on to lab and application support for Dow Chemical Company, providing advanced analytical troubleshooting and method development. In 2019, Jason joined Restek and has focused on air applications."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71513","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/27"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71513"}],"version-history":[{"count":7,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71513\/revisions"}],"predecessor-version":[{"id":104480,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71513\/revisions\/104480"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71513"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71513"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71513"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71513"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71513"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71513"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71513"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71513"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71513"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}