{"id":71785,"date":"2025-11-05T19:17:00","date_gmt":"2025-11-05T19:17:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71785"},"modified":"2026-01-24T02:59:43","modified_gmt":"2026-01-24T02:59:43","slug":"strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-2-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/jpsa2025-02\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-2-ja","title":{"rendered":"PFOS\u30fbPFOA\u898f\u5236\u5f37\u5316\u5bfe\u7b56\uff5c\u4eca\u3053\u305d\u5099\u3048\u308b\uff01\u6c34\u9053\u6cd5\u6539\u6b63\u5bfe\u5fdc PFAS\u5206\u6790\u5b8c\u5168\u30ac\u30a4\u30c92"},"content":{"rendered":"\n<p><strong>\uff1c\u30b7\u30ea\u30fc\u30ba\u8a73\u7d30\uff1e<\/strong><br><strong><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-01\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now!-restek's-complete-guide-to-pfas-analysis-part-1-ja\/\">\u7b2c1\u56de<strong>\uff1a<\/strong>\u6c34\u9053\u6cd5\u6539\u6b63\u306e\u80cc\u666f\u3068\u6982\u8981<\/a><\/strong><br><strong>\u7b2c2\u56de\uff1a\u5236\u5ea6\u6539\u6b63\u306e\u80cc\u666f\u3068PFOS\u30fbPFOA\u306e\u767a\u751f\u6e90\u30ea\u30b9\u30af\u3092\u6b63\u3057\u304f\u7406\u89e3\u3059\u308b<\/strong><br><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-03\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-3-ja\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-03\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-3-ja\/\" rel=\"noreferrer noopener\"><strong>\u7b2c3\u56de\uff1aPFOS\u30fbPFOA\u304c\u4e0e\u3048\u308b\u5065\u5eb7\u30fb\u74b0\u5883\u5f71\u97ff\u3068\u6c34\u8cea\u57fa\u6e96\u306e\u79d1\u5b66\u7684\u6839\u62e0<\/strong><\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-04\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-4-ja\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-04\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-4-ja\/\" rel=\"noreferrer noopener\"><strong>\u7b2c4\u56de\uff1aPFAS\u5206\u6790\u306b\u6c42\u3081\u3089\u308c\u308b\u6280\u8853\u57fa\u6e96\u3068\u7559\u610f\u70b9<\/strong><\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-05\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-5-ja\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-05\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-5-ja\/\" rel=\"noreferrer noopener\"><strong>\u7b2c5\u56de\uff1aPFAS\u5206\u6790\u3092\u652f\u3048\u308bRestek\u88fd\u54c1\u3068\u6700\u65b0\u30e1\u30bd\u30c3\u30c9\u306e\u5c0e\u5165\u4e8b\u4f8b<\/strong><\/a><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u25a0 \u5236\u5ea6\u6539\u6b63\u306e\u80cc\u666f\uff1aPFAS\u3092\u5de1\u308b\u56fd\u969b\u7684\u52d5\u5411\u3068\u56fd\u5185\u306e\u5bfe\u5fdc\u5f37\u5316<\/h2>\n\n\n\n<p>PFAS\u306f\u3001\u305d\u306e\u9ad8\u5ea6\u306a\u5316\u5b66\u7684\u5b89\u5b9a\u6027\u3068\u64a5\u6c34\u30fb\u64a5\u6cb9\u6027\u304b\u3089\u3001\u6570\u5341\u5e74\u306b\u308f\u305f\u3063\u3066\u69d8\u3005\u306a\u5de5\u696d\u88fd\u54c1\u3084\u6d88\u706b\u5264\u3001\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u6750\u306a\u3069\u306b\u4f7f\u7528\u3055\u308c\u3066\u304d\u307e\u3057\u305f\u3002\u4e00\u65b9\u3067\u3001\u305d\u306e\u74b0\u5883\u4e2d\u3067\u306e\u96e3\u5206\u89e3\u6027\uff08Persistent\uff09\u3001\u751f\u4f53\u84c4\u7a4d\u6027\uff08Bioaccumulative\uff09\u3001\u6709\u5bb3\u6027\uff08Toxic\uff09\u304c\u5f90\u3005\u306b\u660e\u3089\u304b\u3068\u306a\u308a\u3001\u4e16\u754c\u5404\u56fd\u3067\u898f\u5236\u306e\u5f37\u5316\u304c\u9032\u3093\u3067\u3044\u307e\u3059\u3002\u7279\u306bPFOS\u304a\u3088\u3073PFOA\u306b\u95a2\u3057\u3066\u306f\u3001OECD\u3084UNEP\u306e\u4e0b\u3067\u300c<strong>POPs\uff08\u6b8b\u7559\u6027\u6709\u6a5f\u6c5a\u67d3\u7269\u8cea\uff09<\/strong>\u300d\u3068\u3057\u3066\u56fd\u969b\u7684\u306a\u524a\u6e1b\u30fb\u5ec3\u7d76\u306e\u5bfe\u8c61\u3068\u3055\u308c\u3066\u304a\u308a\u3001\u7c73\u56fd\u3001EU\u3001\u97d3\u56fd\u3001\u30aa\u30fc\u30b9\u30c8\u30e9\u30ea\u30a2\u306a\u3069\u3067\u306f\u6c34\u9053\u6c34\u3084\u5730\u4e0b\u6c34\u306b\u5bfe\u3057\u3066\u53b3\u3057\u3044\u57fa\u6e96\u5024\u304c\u5c0e\u5165\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u3046\u3057\u305f\u56fd\u969b\u7684\u306a\u52d5\u5411\u306b\u52a0\u3048\u3001\u65e5\u672c\u56fd\u5185\u3067\u3082\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u4e8b\u6848\u304c\u3001PFAS\u306b\u5bfe\u3059\u308b\u793e\u4f1a\u7684\u95a2\u5fc3\u3068\u898f\u5236\u5f37\u5316\u306e\u80cc\u666f\u3068\u3057\u3066\u6319\u3052\u3089\u308c\u307e\u3059\uff1a<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u81ea\u885b\u968a\u57fa\u5730\u3084\u5de5\u5834\u5468\u8fba\u306b\u304a\u3051\u308b\u5730\u4e0b\u6c34\u30fb\u6cb3\u5ddd\u30fb\u571f\u58cc\u306ePFOS\/PFOA\u9ad8\u6fc3\u5ea6\u6c5a\u67d3\u306e\u5831\u9053\u30fb\u4f4f\u6c11\u8abf\u67fb\u306e\u5897\u52a0<\/li>\n\n\n\n<li>\u5404\u81ea\u6cbb\u4f53\u306b\u3088\u308b\u72ec\u81ea\u306ePFAS\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3068\u5bfe\u7b56\u8981\u6c42\u306e\u9ad8\u307e\u308a<\/li>\n\n\n\n<li>\u98df\u54c1\u5b89\u5168\u59d4\u54e1\u4f1a\u3084\u56fd\u7acb\u74b0\u5883\u7814\u7a76\u6240\u306b\u3088\u308b\u6bd2\u6027\u8a55\u4fa1\u3084\u74b0\u5883\u52d5\u614b\u306b\u95a2\u3059\u308b\u65b0\u305f\u306a\u79d1\u5b66\u7684\u77e5\u898b\u306e\u84c4\u7a4d<\/li>\n<\/ul>\n\n\n\n<p>\u3053\u3046\u3057\u305f\u72b6\u6cc1\u3092\u53d7\u3051\u3066\u3001\u539a\u751f\u52b4\u50cd\u7701\u304a\u3088\u3073\u74b0\u5883\u7701\u306f\u3001PFOS\u304a\u3088\u3073PFOA\u3092\u66ab\u5b9a\u76ee\u6a19\u5024\u304b\u3089\u6b63\u5f0f\u306a\u6c34\u8cea\u57fa\u6e96\u9805\u76ee\u304a\u3088\u3073\u6307\u91dd\u5024\u3078\u683c\u4e0a\u3052\u3059\u308b\u3053\u3068\u3092\u6c7a\u5b9a\u3057\u307e\u3057\u305f\u3002\u6c34\u9053\u6cd5\u65bd\u884c\u898f\u5247\u7b49\u306e\u6539\u6b63\u306b\u3088\u308a\u3001\u4ee4\u548c8\u5e74\uff082026\u5e74\uff094\u67081\u65e5\u304b\u3089\u3001\u6c34\u9053\u6c34\u4e2d\u306e<strong>PFOS\uff0bPFOA\u5408\u7b97\u306750 ng\/L\u4ee5\u4e0b<\/strong>\u3068\u3044\u3046\u65b0\u305f\u306a\u57fa\u6e96\u5024\u304c\u9069\u7528\u3055\u308c\u308b\u3053\u3068\u3068\u306a\u308a\u307e\u3057\u305f\u3002\u3053\u306e\u6539\u6b63\u306f\u3001\u5358\u306a\u308b\u6570\u5024\u57fa\u6e96\u306e\u5909\u66f4\u306b\u3068\u3069\u307e\u3089\u305a\u3001PFAS\u306e\u5206\u6790\u30fb\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u4f53\u5236\u305d\u306e\u3082\u306e\u3092\u898b\u76f4\u3059\u5fc5\u8981\u6027\u3092\u7a81\u304d\u3064\u3051\u308b\u3082\u306e\u3067\u3082\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u307e\u3067\u4e00\u90e8\u306e\u81ea\u6cbb\u4f53\u3084\u7814\u7a76\u6a5f\u95a2\u304c\u72ec\u81ea\u306b\u9032\u3081\u3066\u3044\u305fPFAS\u6e2c\u5b9a\u304c\u3001\u4eca\u5f8c\u306f\u5168\u56fd\u7684\u306a\u300c\u7fa9\u52d9\u5316\u3055\u308c\u305f\u5236\u5ea6\u904b\u7528\u300d\u3068\u3057\u3066\u672c\u683c\u5316\u3059\u308b\u3053\u3068\u306b\u306a\u308a\u3001\u5206\u6790\u7cbe\u5ea6\u3001\u691c\u51fa\u9650\u754c\u3001\u88c5\u7f6e\u69cb\u6210\u3001\u524d\u51e6\u7406\u6280\u8853\u3001\u6a19\u6e96\u7269\u8cea\u306e\u54c1\u8cea\u306a\u3069\u3001\u3042\u3089\u3086\u308b\u5206\u6790\u8981\u7d20\u306e\u518d\u70b9\u691c\u3068\u518d\u69cb\u7bc9\u304c\u6c42\u3081\u3089\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3: PFAS\u306e\u4f7f\u7528\u304c\u78ba\u8a8d\u3055\u308c\u308b\u8eab\u8fd1\u306a\u3082\u306e<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-3-1024x576.jpg\" alt=\"\" class=\"wp-image-71794\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-3-1024x576.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-3-300x169.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-3-768x432.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-3.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\"><span style=\"font-family: inherit;\">\u25a0 &nbsp; &nbsp;PFOS\u30fbPFOA \u306e\u767a\u751f\u53ef\u80fd\u7b87\u6240\u3068\u6c34\u74b0\u5883\u3078\u306e\u6d41\u5165\u7d4c\u8def<\/span><\/h2>\n\n\n\n<p>PFOS\u304a\u3088\u3073PFOA\u306f\u3001\u904e\u53bb\u306b\u5e83\u7bc4\u306a\u7523\u696d\u7528\u9014\u3067\u5229\u7528\u3055\u308c\u3066\u304d\u305f\u80cc\u666f\u304b\u3089\u3001\u65e2\u5b58\u30a4\u30f3\u30d5\u30e9\u3084\u5468\u8fba\u74b0\u5883\u306b\u5e83\u304f\u6b8b\u7559\u3057\u3066\u3044\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u4f7f\u7528\u6642\u3060\u3051\u3067\u306a\u304f\u3001\u8001\u673d\u5316\u30fb\u52a3\u5316\u30fb\u5ec3\u68c4\u51e6\u7406\u30fb\u6d17\u6d44\u30fb\u706b\u707d\u8a13\u7df4\u306a\u3069\u306e\u5834\u9762\u3067\u3082\u74b0\u5883\u4e2d\u3078\u518d\u653e\u51fa\u3055\u308c\u308b\u30ea\u30b9\u30af\u304c\u3042\u308a\u3001\u6c34\u9053\u6c34\u6e90\u306e\u6c5a\u67d3\u7d4c\u8def\u3068\u306a\u308a\u5f97\u307e\u3059\u3002\u4ee5\u4e0b\u306b\u3001\u7279\u306bPFAS\u304c\u6c34\u74b0\u5883\u3078\u6d41\u5165\u3057\u3084\u3059\u3044\u3068\u3055\u308c\u308b\u4e3b\u8981\u306a\u767a\u751f\u6e90\u304a\u3088\u3073\u7d4c\u8def\u3092\u6574\u7406\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><strong>\u767a\u751f\u7b87\u6240<\/strong><\/td><td><strong>\u60f3\u5b9a\u3055\u308c\u308b\u6d41\u5165\u7d4c\u8def\u30fb\u30ea\u30b9\u30af<\/strong><\/td><\/tr><tr><td>\u6d88\u706b\u8a2d\u5099\uff08AFFF\u578b\u6ce1\u6d88\u706b\u5264\uff09<\/td><td>\u8a13\u7df4\u6642\u30fb\u5b9f\u7a3c\u50cd\u6642\u306e\u6ce1\u5264\u6563\u5e03\u3001\u6d88\u706b\u65bd\u8a2d\u304b\u3089\u306e\u6b8b\u7559\u6eb6\u51fa\u3002PFAS \u542b\u6709\u6ce1\u5264\u306f\u8fd1\u5e74\u307e\u3067\u5e83\u304f\u4f7f\u7528\u3055\u308c\u3066\u3044\u305f\u305f\u3081\u3001\u6d88\u9632\u65bd\u8a2d\u5468\u8fba\u306e\u5730\u4e0b\u6c34\u6c5a\u67d3\u3082\u5831\u544a\u3042\u308a\u3002<\/td><\/tr><tr><td>\u5de5\u696d\u7cfb\u6392\u6c34\u30fb\u88fd\u9020\u5de5\u7a0b<\/td><td>\u7279\u5b9a\u306e\u64a5\u6c34\u30fb\u64a5\u6cb9\u88fd\u54c1\u3001\u8868\u9762\u51e6\u7406\u6750\u3001\u30e1\u30c3\u30ad\u3001\u534a\u5c0e\u4f53\u6d17\u6d44\u7b49\u3067PFAS\u304c\u4f7f\u7528\u30fb\u751f\u6210\u3055\u308c\u308b\u5834\u5408\u3001\u6d17\u6d44\u6392\u6c34\u3084\u526f\u751f\u6210\u7269\u304b\u3089\u306e\u6f0f\u51fa\u304c\u61f8\u5ff5\u3055\u308c\u308b\u3002<\/td><\/tr><tr><td>\u571f\u58cc\u30fb\u6c5a\u6ce5\u304b\u3089\u306e\u6d78\u51fa<\/td><td>\u5ec3\u68c4\u7269\u57cb\u7acb\u5730\u3001\u4e0b\u6c34\u6c5a\u6ce5\u65bd\u7528\u5730\u306a\u3069\u3001\u904e\u53bb\u306b\u84c4\u7a4d\u3055\u308c\u305fPFAS\u304c\u9577\u671f\u9593\u306b\u308f\u305f\u308a\u5730\u4e0b\u6c34\u3078\u6d78\u51fa\u3059\u308b\u30b1\u30fc\u30b9\u304c\u3042\u308b\u3002<\/td><\/tr><tr><td>\u64a5\u6c34\u30fb\u64a5\u6cb9\u6027\u6750\u6599\u3001\u30d5\u30c3\u7d20\u6a39\u8102\u52a0\u5de5\u90e8\u54c1\u7b49<\/td><td>\u88fd\u54c1\u8001\u673d\u5316\u3001\u6469\u8017\u3001\u6d17\u6d44\u5de5\u7a0b\u3092\u901a\u3058\u3066\u3001\u88fd\u54c1\u4e2d\u306e\u6b8b\u7559 PFAS \u304c\u6c34\u7cfb\u3078\u6d41\u51fa\u3059\u308b\u53ef\u80fd\u6027\u3042\u308a\u3002\u88fd\u9020\u30fb\u89e3\u4f53\u73fe\u5834\u7b49\u3067\u7279\u306b\u6ce8\u610f\u304c\u5fc5\u8981\u3002<\/td><\/tr><tr><td>\u6d44\u6c34\u51e6\u7406\u65bd\u8a2d\uff08\u6d3b\u6027\u70ad\u306a\u3069\u5438\u7740\u6750\uff09<\/td><td>\u5438\u7740\u6750\u306e\u7a2e\u985e\u3084\u5bff\u547d\u306b\u3088\u3063\u3066\u3001\u5438\u7740\u6027\u80fd\u304c\u52a3\u5316\u3057\u305f\u5834\u5408\u306bPFAS\u304c\u51e6\u7406\u6c34\u4e2d\u3078\u518d\u653e\u51fa\u3055\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u3002\u4ea4\u63db\u7ba1\u7406\u3084\u6750\u8cea\u9078\u5b9a\u304c\u91cd\u8981\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4: \u5e83\u7bc4\u56f2\u306b\u308f\u305f\u308bPFAS\u304c\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u5206\u91ce<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-4-1024x576.jpg\" alt=\"\" class=\"wp-image-71800\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-4-1024x576.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-4-300x169.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-4-768x432.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-02-Figure-4.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>PFOS\u3001PFOA\u306e\u5b9f\u614b\u304c\u5206\u304b\u3063\u305f\u3068\u601d\u3044\u307e\u3059\u3002<br>\u6b21\u306b\u77e5\u3063\u3066\u9802\u304d\u305f\u3044\u306e\u306f\u3001<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-03\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-3-ja\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-03\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-3-ja\/\" rel=\"noreferrer noopener\">\u7b2c3\u56de\uff1aPFOS\u30fbPFOA\u304c\u4e0e\u3048\u308b\u5065\u5eb7\u30fb\u74b0\u5883\u5f71\u97ff\u3068\u6c34\u8cea\u57fa\u6e96\u306e\u79d1\u5b66\u7684\u6839\u62e0<\/a>\u3067\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>2026\u5e74\u65bd\u884c\u306e\u6c34\u9053\u6cd5\u6539\u6b63\u306b\u3088\u308a\u3001PFOS\u30fbPFOA\u306e\u898f\u5236\u304c\u5f37\u5316\u3002PFAS\u5206\u6790\u306b\u5fc5\u8981\u306a\u30ea\u30b9\u30af\u7406\u89e3\u3084\u6c34\u8cea\u57fa\u6e96\u306e\u80cc\u666f\u3092\u74b0\u5883\u7701\u306e\u8cc7\u6599\u3092\u53c2\u7167\u3057\u3064\u3064\u3001\u5c02\u9580\u7684\u8996\u70b9\u304b\u3089\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[789],"tags":[2761],"industries-application":[2288,2271,2287],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-71785","post","type-post","status-publish","format-standard","hentry","category-articles-ja","tag-ja-only","industries-application-pfas-testing-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2761,"label":"JA-Only"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":459,"filter":"raw","cat_ID":789,"category_count":459,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2761,"name":"JA-Only","slug":"ja-only","term_group":0,"term_taxonomy_id":2761,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71785","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71785"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71785\/revisions"}],"predecessor-version":[{"id":84470,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71785\/revisions\/84470"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71785"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71785"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71785"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71785"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71785"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71785"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71785"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71785"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71785"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}