{"id":71818,"date":"2025-11-05T20:03:00","date_gmt":"2025-11-05T20:03:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71818"},"modified":"2026-01-24T03:02:55","modified_gmt":"2026-01-24T03:02:55","slug":"strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-3-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/jpsa2025-03\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-3-ja","title":{"rendered":"PFOS\u30fbPFOA\u898f\u5236\u5f37\u5316\u5bfe\u7b56\uff5c\u4eca\u3053\u305d\u5099\u3048\u308b\uff01\u6c34\u9053\u6cd5\u6539\u6b63\u5bfe\u5fdc PFAS\u5206\u6790\u5b8c\u5168\u30ac\u30a4\u30c93"},"content":{"rendered":"\n<p><strong>\uff1c\u30b7\u30ea\u30fc\u30ba\u8a73\u7d30\uff1e<\/strong><br><strong><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-01\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now!-restek's-complete-guide-to-pfas-analysis-part-1-ja\/\">\u7b2c1\u56de<strong>\uff1a<\/strong>\u6c34\u9053\u6cd5\u6539\u6b63\u306e\u80cc\u666f\u3068\u6982\u8981<\/a><\/strong><br><strong><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-01\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now!-restek's-complete-guide-to-pfas-analysis-part-2-ja\/\">\u7b2c2\u56de\uff1a\u5236\u5ea6\u6539\u6b63\u306e\u80cc\u666f\u3068PFOS\u30fbPFOA\u306e\u767a\u751f\u6e90\u30ea\u30b9\u30af\u3092\u6b63\u3057\u304f\u7406\u89e3\u3059\u308b<\/a><br>\u7b2c3\u56de\uff1aPFOS\u30fbPFOA\u304c\u4e0e\u3048\u308b\u5065\u5eb7\u30fb\u74b0\u5883\u5f71\u97ff\u3068\u6c34\u8cea\u57fa\u6e96\u306e\u79d1\u5b66\u7684\u6839\u62e0<br><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-01\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now!-restek's-complete-guide-to-pfas-analysis-part-4-ja\/\">\u7b2c4\u56de\uff1aPFAS\u5206\u6790\u306b\u6c42\u3081\u3089\u308c\u308b\u6280\u8853\u57fa\u6e96\u3068\u7559\u610f\u70b9<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-01\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now!-restek's-complete-guide-to-pfas-analysis-part-5-ja\/\">\u7b2c5\u56de\uff1aPFAS\u5206\u6790\u3092\u652f\u3048\u308bRestek\u88fd\u54c1\u3068\u6700\u65b0\u30e1\u30bd\u30c3\u30c9\u306e\u5c0e\u5165\u4e8b\u4f8b<\/a><\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u25a0 &nbsp; &nbsp;PFOS\u30fbPFOA \u306e\u5065\u5eb7\u5f71\u97ff\u304a\u3088\u3073\u74b0\u5883\u30ea\u30b9\u30af<\/h2>\n\n\n\n<p>PFOS\u304a\u3088\u3073PFOA\u306f\u3001\u81ea\u7136\u754c\u3067\u306e\u5206\u89e3\u304c\u6975\u3081\u3066\u56f0\u96e3\u3067\u3042\u308a\u3001\u304b\u3064\u751f\u4f53\u5185\u3067\u306e\u84c4\u7a4d\u6027\u304c\u9ad8\u3044\u3053\u3068\u304b\u3089\u3001\u8fd1\u5e74\u306e\u6bd2\u6027\u8a55\u4fa1\u30fb\u75ab\u5b66\u7814\u7a76\u306b\u3088\u308a\u3001\u6b21\u306e\u3088\u3046\u306a\u5f71\u97ff\u304c\u5831\u544a\u30fb\u793a\u5506\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> <strong>PFOS\u3068PFOA\u306e\u69cb\u9020<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"387\" height=\"97\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-3-Figure-5.png\" alt=\"\" class=\"wp-image-71823\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-3-Figure-5.png 387w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-3-Figure-5-300x75.png 300w\" sizes=\"auto, (max-width: 387px) 100vw, 387px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\">\uff1c\u4e3b\u306a\u7279\u6027\u3068\u74b0\u5883\u3078\u306e\u30ea\u30b9\u30af\uff1e<\/h3>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>\u7279\u6027<\/td><td>\u5185\u5bb9<\/td><\/tr><tr><td>\u96e3\u5206\u89e3\u6027\uff08Persistence\uff09<\/td><td>\u4e00\u822c\u7684\u306a\u74b0\u5883\u6761\u4ef6\u4e0b\u3067\u306f\u5316\u5b66\u7684\u306b\u5b89\u5b9a\u3067\u3001\u9577\u671f\u9593\u306b\u308f\u305f\u308a\u6c34\u30fb\u571f\u58cc\u4e2d\u306b\u6b8b\u7559\u3002\u713c\u5374\u51e6\u7406\u3067\u3082\u5206\u89e3\u306b\u9ad8\u6e29\u304c\u5fc5\u8981\u3002<\/td><\/tr><tr><td>\u751f\u4f53\u84c4\u7a4d\u6027\uff08Bioaccumulation\uff09<\/td><td>\u30d2\u30c8\u3092\u542b\u3080\u54fa\u4e73\u985e\u3084\u9b5a\u985e\u306b\u304a\u3044\u3066\u3001\u8840\u4e2d\u30fb\u809d\u81d3\u30fb\u6bcd\u4e73\u7b49\u306b\u84c4\u7a4d\u3002\u534a\u6e1b\u671f\u306f\u6570\u5e74\u306b\u53ca\u3076\u3068\u3055\u308c\u308b\u3002<\/td><\/tr><tr><td>\u9577\u8ddd\u96e2\u79fb\u52d5\u6027\uff08Mobility\uff09<\/td><td>\u6975\u3081\u3066\u9ad8\u3044\u6c34\u6eb6\u6027\u3068\u4f4e\u5438\u7740\u6027\u306b\u3088\u308a\u3001\u5730\u4e0b\u6c34\u30fb\u6cb3\u5ddd\u3092\u4ecb\u3057\u3066\u5e83\u7bc4\u56f2\u306b\u62e1\u6563\u3002\u6cb3\u5ddd\u6d41\u57df\u3092\u8d8a\u3048\u3066\u691c\u51fa\u3055\u308c\u308b\u4f8b\u3082\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><br>\uff1c\u5065\u5eb7\u5f71\u97ff\uff08\u6307\u6458\u3055\u308c\u3066\u3044\u308b\u4e3b\u306a\u9805\u76ee\uff09\uff1e<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u767a\u304c\u3093\u6027\u306e\u53ef\u80fd\u6027\uff08IARC\uff1aPFOA\u3092\u300c2B\uff1d\u30d2\u30c8\u306b\u5bfe\u3059\u308b\u767a\u304c\u3093\u6027\u304c\u3042\u308b\u304b\u3082\u3057\u308c\u306a\u3044\u300d\u306b\u5206\u985e\uff09<\/li>\n\n\n\n<li>\u809d\u6a5f\u80fd\u969c\u5bb3\u3001\u8102\u8cea\u4ee3\u8b1d\u7570\u5e38<\/li>\n\n\n\n<li>\u751f\u6b96\u6bd2\u6027\u30fb\u80ce\u5150\u767a\u80b2\u3078\u306e\u5f71\u97ff<\/li>\n\n\n\n<li>\u514d\u75ab\u6a5f\u80fd\u6291\u5236\u3001\u30ef\u30af\u30c1\u30f3\u5fdc\u7b54\u306e\u4f4e\u4e0b<\/li>\n\n\n\n<li>\u5185\u5206\u6ccc\u304b\u304f\u4e71\u4f5c\u7528\u306e\u53ef\u80fd\u6027<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u25a0 \u6c34\u8cea\u57fa\u6e96\u306e\u79d1\u5b66\u7684\u6839\u62e0\uff1a50 ng\/L\u3092\u8a2d\u5b9a\u3057\u305f\u8907\u6570\u306e\u8981\u7d20<\/h2>\n\n\n\n<p>PFOS\u304a\u3088\u3073PFOA\u306b\u5bfe\u3059\u308b<strong>\u6c34\u8cea\u57fa\u6e96\u5024\u300c\u5408\u7b97\u306750 ng\/L\u300d<\/strong>\u3068\u3044\u3046\u6570\u5024\u306f\u3001\u5358\u306b\u6d77\u5916\u306e\u898f\u5236\u5024\u3092\u6a21\u5023\u3057\u305f\u3082\u306e\u3067\u306f\u306a\u304f\u3001\u98df\u54c1\u5b89\u5168\u59d4\u54e1\u4f1a\u306b\u3088\u308b\u6700\u65b0\u306e\u5065\u5eb7\u30ea\u30b9\u30af\u8a55\u4fa1\u3068\u3001\u5b9f\u969b\u306e\u6c34\u9053\u6c34\u4e2d\u6fc3\u5ea6\u306e\u5206\u5e03\u3001\u5206\u6790\u6280\u8853\u306e\u9650\u754c\u3001\u56fd\u969b\u7684\u6574\u5408\u6027\u306a\u3069\u3001\u8907\u6570\u306e\u8981\u7d20\u3092\u7dcf\u5408\u7684\u306b\u52d8\u6848\u3057\u305f\u3046\u3048\u3067\u8a2d\u5b9a\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6: \u6c34\u8cea\u57fa\u6e96\u5024\u306e\u7b97\u51fa\u65b9\u6cd5<\/strong><\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n\n<p>\uff08<a href=\"https:\/\/www.env.go.jp\/content\/000334172.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u74b0\u5883\u7701\u300c\u6c34\u8cea\u57fa\u6e96\u306b\u95a2\u3059\u308b\u7701\u4ee4\u6539\u6b63\u306e\u6982\u8981\u306b\u3064\u3044\u3066\u300d\uff08\u4ee4\u548c7\u5e748\u67088\u65e5&nbsp; \u6c34\u9053\u6c34\u8cea\u30fb\u885b\u751f\u7ba1\u7406\u5ba4\uff09<\/a>\u3088\u308a\uff09<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-03-Figure-6-1024x576.jpg\" alt=\"\" class=\"wp-image-71829\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-03-Figure-6-1024x576.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-03-Figure-6-300x169.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-03-Figure-6-768x432.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/JPSA2025-03-Figure-6.jpg 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>\u9805\u76ee<\/td><td>\u5185\u5bb9<\/td><\/tr><tr><td>\u6bd2\u6027\u8a55\u4fa1<\/td><td>\u8010\u5bb9\u4e00\u65e5\u6442\u53d6\u91cf\uff1a\u4eba\u304c\u3001\u6c34\u306e\u98f2\u7528\u4ee5\u5916\u306e\u7d4c\u8def\u304b\u3089\u306e\u6442\u53d6\u3092\u542b\u3081\u3001\u4e00\u751f\u6daf\u306b\u6e21\u3063\u3066\u6442\u53d6\u3057\u7d9a\u3051\u3066\u3082\u3001\u5065\u5eb7\u3078\u306e\u60aa\u5f71\u97ff\u304c\u306a\u3044\u3068\u63a8\u5b9a\u3055\u308c\u308b\u3001\u4f53\u91cd1 Kg\u5f53\u305f\u308a\u30011\u65e5\u5f53\u305f\u308a\u306e\u7269\u8cea\u306e\u6442\u53d6\u91cf\u3002<\/td><\/tr><tr><td>TDI<\/td><td>\u4ee4\u548c6\u5e746\u6708\u306b\u5185\u95a3\u5e9c\u98df\u54c1\u5b89\u5168\u59d4\u54e1\u4f1a\u304c\u3001\u8af8\u5916\u56fd\u30fb\u6a5f\u95a2\u304c\u884c\u3063\u305f\u8a55\u4fa1\u306e\u4e2d\u3067\u4f7f\u7528\u3055\u308c\u305f\u6839\u62e0\u8cc7\u6599\u3092\u542b\u3081\u3066\u8a55\u4fa1\u3057\u305f\u4e0a\u3067\u8a55\u4fa1\u66f8\u3092\u53d6\u308a\u307e\u3068\u3081\u3001\u305d\u308c\u305e\u308c\u8010\u5bb9\u4e00\u65e5\u6442\u53d6\u91cf\uff08TDI\uff09\u304c\u793a\u3055\u308c\u305f\u27a1\u2460<strong>PFOS<\/strong>\u306b\u3064\u3044\u3066\u306f\u300120 ng\/kg\/day \uff1a\u5150\u52d5\u7269\u306b\u304a\u3051\u308b\u4f53\u91cd\u5897\u52a0\u6291\u5236\u3000\u2461<strong>PFOA<\/strong>\u306b\u3064\u3044\u3066\u306f\u300120 ng\/kg\/day \uff1a\u80ce\u5150\u306e\u524d\u80a2\u53ca\u3073\u5f8c\u80a2\u306e\u8fd1\u4f4d\u6307\u7bc0\u9aa8\u306e\u9aa8\u5316\u90e8\u4f4d\u6570\u306e\u6e1b\u5c11\u3001\u96c4\u306e\u5150\u52d5\u7269\u306e\u6027\u6210\u719f\u4fc3\u9032<\/td><\/tr><tr><td>\u6c34\u306e\u98f2\u7528\u306b\u4fc2\u308b\u5272\u5f53\u7387<\/td><td>\u6c34\u306e\u98f2\u7528\u4ee5\u5916\u306e\u7d4c\u8def\u304b\u3089<strong>PFOS<\/strong>\u7b49\u304c\u6442\u53d6\u3055\u308c\u308b\u3053\u3068\u3082\u898b\u8d8a\u3057\u3066\u3001\u305d\u306e\u5206\u3001\u6c34\u306e\u98f2\u7528\u304b\u3089\u306e\u6442\u53d6\u91cf\u3092\u3069\u306e\u7a0b\u5ea6\u307e\u3067\u6291\u5236\u3057\u3066\u304a\u304f\u5fc5\u8981\u304c\u3042\u308b\u304b\u3092\u8a2d\u5b9a\u3057\u305f\u6570\u5024\u3002<\/td><\/tr><tr><td>\u57fa\u6e96\u5024<\/td><td>\u2460<strong>PFOS<\/strong>\u3001<strong>PFOA<\/strong>\u305d\u308c\u305e\u308c50 ng\/L\u3000\u2461\u6c34\u8cea\u57fa\u6e96\u5024\u306f\u3088\u308a\u5b89\u5168\u5074\u306b<strong>PFOS<\/strong>\u3068<strong>PFOA<\/strong>\u306e\u5408\u7b97\u306750 ng\/L&nbsp;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u25a0\u300c\u5408\u7b97\u5024\u300d\u8a2d\u5b9a\u306e\u7406\u7531\u3068\u610f\u7fa9<\/h2>\n\n\n\n<p>\u6c34\u8cea\u57fa\u6e96\u3067\u306f\u3001PFOS\u304a\u3088\u3073PFOA\u3092\u500b\u5225\u3067\u306f\u306a\u304f\u300c\u5408\u7b97\u5024\u300d\u3067\u8a55\u4fa1\u3059\u308b\u65b9\u5f0f\u304c\u63a1\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u4ee5\u4e0b\u306e\u79d1\u5b66\u7684\u30fb\u5236\u5ea6\u7684\u80cc\u666f\u3092\u53cd\u6620\u3057\u305f\u3082\u306e\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td>\u89b3\u70b9<\/td><td>\u5185\u5bb9<\/td><\/tr><tr><td>\u6bd2\u6027\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u985e\u4f3c\u6027<\/td><td>PFOS\u3068PFOA\u306f\u5171\u306bPFCs\uff08\u30d1\u30fc\u30d5\u30eb\u30aa\u30ed\u5316\u5408\u7269\uff09\u306b\u5c5e\u3057\u3001\u4f53\u5185\u52d5\u614b\u3084\u6bd2\u6027\u767a\u73fe\u7d4c\u8def\u304c\u985e\u4f3c\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u5408\u7b97\u3067\u30ea\u30b9\u30af\u8a55\u4fa1\u53ef\u80fd\u3068\u5224\u65ad\u3002<\/td><\/tr><tr><td>\u5206\u6790\u306e\u5b9f\u52d9\u6027<\/td><td>\u591a\u304f\u306e\u5206\u6790\u624b\u6cd5\uff08\u4f8b\uff1aEPA Method 533\uff09\u3067\u306f\u3001PFOS\u3068PFOA\u3092\u540c\u6642\u306b\u691c\u51fa\u30fb\u5b9a\u91cf\u3067\u304d\u308b\u305f\u3081\u3001\u5b9f\u52d9\u4e0a\u306e\u691c\u67fb\u5bb9\u6613\u6027\u30fb\u518d\u73fe\u6027\u306b\u3082\u914d\u616e\u3057\u305f\u8a2d\u8a08\u3002<\/td><\/tr><tr><td>\u7d2f\u7a4d\u7684\u3070\u304f\u9732\u306e\u7ba1\u7406<\/td><td>\u5b9f\u74b0\u5883\u4e2d\u3067\u306f\u3001\u4e21\u8005\u304c\u4f75\u5b58\u3057\u3066\u3044\u308b\u30b1\u30fc\u30b9\u304c\u591a\u304f\u3001\u300c\u5408\u7b97\u5024\u300d\u3067\u306e\u7ba1\u7406\u304c\u5b9f\u969b\u7684\u306a\u30ea\u30b9\u30af\u6291\u5236\u306b\u6709\u52b9\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u30ea\u30b9\u30af\u3084\u691c\u67fb\u57fa\u6e96\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u628a\u63e1\u3067\u304d\u305f\u3089\u3001\u6b21\u306b\u62bc\u3055\u3048\u3066\u304a\u304f\u3079\u304d\u306f\u5b9f\u969b\u306e\u5206\u6790\u306b\u4f55\u304c\u5fc5\u8981\u304b\u3001\u306b\u306a\u308b\u3067\u3057\u3087\u3046\u3002\u3053\u3061\u3089\u304b\u3089\u3054\u78ba\u8a8d\u4e0b\u3055\u3044\u3002\u261e<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-04\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-4-ja\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-04\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-4-ja\/\" rel=\"noreferrer noopener\">\u7b2c4\u56de\uff1aPFAS\u5206\u6790\u306b\u6c42\u3081\u3089\u308c\u308b\u6280\u8853\u57fa\u6e96\u30fb\u691c\u67fb\u5236\u5ea6\u3068\u7559\u610f\u70b9<\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>2026\u5e74\u65bd\u884c\u306e\u6c34\u9053\u6cd5\u6539\u6b63\u306b\u3088\u308a\u3001PFOS\u30fbPFOA\u306e\u898f\u5236\u304c\u5f37\u5316\u3002PFAS\u5206\u6790\u306b\u5fc5\u8981\u306a\u30ea\u30b9\u30af\u7406\u89e3\u3084\u6c34\u8cea\u57fa\u6e96\u306e\u80cc\u666f\u3092\u74b0\u5883\u7701\u306e\u8cc7\u6599\u3092\u53c2\u7167\u3057\u3064\u3064\u3001\u5c02\u9580\u7684\u8996\u70b9\u304b\u3089\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[789],"tags":[],"industries-application":[2288,2271,2287],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-71818","post","type-post","status-publish","format-standard","hentry","category-articles-ja","industries-application-pfas-testing-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":459,"filter":"raw","cat_ID":789,"category_count":459,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71818","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71818"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71818\/revisions"}],"predecessor-version":[{"id":84474,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71818\/revisions\/84474"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71818"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71818"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71818"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71818"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71818"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71818"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71818"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71818"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71818"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}