{"id":71851,"date":"2025-11-05T20:31:00","date_gmt":"2025-11-05T20:31:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=71851"},"modified":"2026-06-03T01:47:23","modified_gmt":"2026-06-03T01:47:23","slug":"strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-4-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/jpsa2025-04\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-4-ja","title":{"rendered":"PFOS\u30fbPFOA\u898f\u5236\u5f37\u5316\u5bfe\u7b56\uff5c\u4eca\u3053\u305d\u5099\u3048\u308b\uff01\u6c34\u9053\u6cd5\u6539\u6b63\u5bfe\u5fdc PFAS\u5206\u6790\u5b8c\u5168\u30ac\u30a4\u30c94"},"content":{"rendered":"\n<p><strong>\uff1c\u30b7\u30ea\u30fc\u30ba\u8a73\u7d30\uff1e<\/strong><br><strong><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-01\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now!-restek's-complete-guide-to-pfas-analysis-part-1-ja\/\">\u7b2c1\u56de<strong>\uff1a<\/strong>\u6c34\u9053\u6cd5\u6539\u6b63\u306e\u80cc\u666f\u3068\u6982\u8981<\/a><\/strong><br><strong><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-01\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now!-restek's-complete-guide-to-pfas-analysis-part-2-ja\/\">\u7b2c2\u56de\uff1a\u5236\u5ea6\u6539\u6b63\u306e\u80cc\u666f\u3068PFOS\u30fbPFOA\u306e\u767a\u751f\u6e90\u30ea\u30b9\u30af\u3092\u6b63\u3057\u304f\u7406\u89e3\u3059\u308b<\/a><br><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-01\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now!-restek's-complete-guide-to-pfas-analysis-part-3-ja\/\">\u7b2c3\u56de\uff1aPFOS\u30fbPFOA\u304c\u4e0e\u3048\u308b\u5065\u5eb7\u30fb\u74b0\u5883\u5f71\u97ff\u3068\u6c34\u8cea\u57fa\u6e96\u306e\u79d1\u5b66\u7684\u6839\u62e0<\/a><br>\u7b2c4\u56de\uff1aPFAS\u5206\u6790\u306b\u6c42\u3081\u3089\u308c\u308b\u6280\u8853\u57fa\u6e96\u3068\u7559\u610f\u70b9<br><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-01\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now!-restek's-complete-guide-to-pfas-analysis-part-5-ja\/\">\u7b2c5\u56de\uff1aPFAS\u5206\u6790\u3092\u652f\u3048\u308bRestek\u88fd\u54c1\u3068\u6700\u65b0\u30e1\u30bd\u30c3\u30c9\u306e\u5c0e\u5165\u4e8b\u4f8b<\/a><\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u25a0\u3000\u6280\u8853\u57fa\u6e96\u3068\u3057\u3066\u6c42\u3081\u3089\u308c\u308b\u5206\u6790\u8981\u4ef6<\/h2>\n\n\n\n<p>PFAS\u5206\u6790\u306f\u3001\u5236\u5ea6\u5bfe\u5fdc\u4e0a\u306e\u8981\u4ef6\u3092\u6e80\u305f\u3059\u3060\u3051\u3067\u306a\u304f\u3001\u8aa4\u691c\u51fa\u30fb\u507d\u9670\u6027\u3092\u6392\u9664\u3057\u3046\u308b\u5206\u6790\u7cbe\u5ea6\u3068\u54c1\u8cea\u4fdd\u8a3c\u4f53\u5236\u306e\u69cb\u7bc9\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u4ee5\u4e0b\u306f\u3001\u73fe\u884c\u306e\u56fd\u969b\u7684\u624b\u6cd5\uff08\u4f8b\uff1aEPA Method 533\uff09\u3084\u74b0\u5883\u5206\u6790\u306e\u5b9f\u52d9\u4e0a\u306e\u30d9\u30b9\u30c8\u30d7\u30e9\u30af\u30c6\u30a3\u30b9\u3092\u8e0f\u307e\u3048\u305f\u3001\u5fc5\u8981\u306a\u6280\u8853\u57fa\u6e96\u306e\u8981\u70b9\u3067\u3059\u3002<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u25b8 \u5b9a\u91cf\u4e0b\u9650\uff08LOQ\uff09\u306f10 ng\/L\u4ee5\u4e0b\u304c\u671b\u307e\u3057\u3044<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u73fe\u884c\u306e\u6c34\u9053\u6c34\u8cea\u57fa\u6e96\u5024\u306f PFOS\u30fbPFOA \u5408\u7b97\u3067 50 ng\/L \u306b\u8a2d\u5b9a\u3055\u308c\u3066\u3044\u308b\u304c\u3001\u5236\u5ea6\u4e0a\u306f\u3053\u306e 1\/5 \u306b\u3042\u305f\u308b 10 ng\/L \u3092\u95be\u5024\u3068\u3057\u3066\u691c\u67fb\u983b\u5ea6\u3092\u6c7a\u3081\u308b\u65b9\u5411\u6027\uff08\u306a\u304a\u3001\u56fd\u969b\u7684\u306a\u5206\u6790\u624b\u6cd5\uff08\u4f8b\uff1aEPA Method 533\uff09\u3067\u306f\u3001\u5404 PFAS \u6210\u5206\u3054\u3068\u306b 2\u301c5 ng\/L \u7a0b\u5ea6\u306e MRL \u304c\u8a2d\u5b9a\u3055\u308c\u3066\u3044\u308b\uff09<\/li>\n\n\n\n<li>\u74b0\u5883\u7701\u306e\u6280\u8853\u57fa\u6e96\u3068\u3057\u3066\u300cLOQ=10 ng\/L\u300d\u3068\u306e\u660e\u8a18\u306f\u306a\u3044\u304c\u3001\u56fd\u5185\u306e\u5236\u5ea6\u80cc\u666f\u3068\u56fd\u969b\u7684\u30d9\u30b9\u30c8\u30d7\u30e9\u30af\u30c6\u30a3\u30b9\u3092\u8e0f\u307e\u3048\u308b\u3068\u3001\u76ee\u7684\u306b\u5fdc\u3058\u30665\u301c10 ng\/L \u7a0b\u5ea6\u3092\u76ee\u6a19\u3068\u3059\u308b\u306e\u304c\u73fe\u5b9f\u7684\u306a\u30e9\u30a4\u30f3<\/li>\n<\/ul>\n\n\n\n<p>\u3010\u53c2\u7167\u8cc7\u6599\u3011<\/p>\n\n\n\n<p>\u3000\u3000\u3000\u3000\u3000\u25ce\u6c34\u8cea\u57fa\u6e96\u306b\u95a2\u3059\u308b\u7701\u4ee4\u306e\u4e00\u90e8\u6539\u6b63\u53ca\u3073\u6c34\u9053\u6cd5\u65bd\u884c\u898f\u5247\u306e\u4e00\u90e8\u6539\u6b63\u7b49\u306b\u304a\u3051\u308b \u7559\u610f\u4e8b\u9805\u306b\u3064\u3044\u3066<br>\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u7b2c\uff11\u6c34\u8cea\u57fa\u6e96\u306b\u95a2\u3059\u308b\u7701\u4ee4\u53ca\u3073\u6c34\u9053\u6cd5\u65bd\u884c\u898f\u5247\u306e\u4e00\u90e8\u6539\u6b63\u306b\u4fc2\u308b\u7559\u610f\u4e8b\u9805&nbsp;<br>\u3000\u3000\u3000\u3000\u3000\u3000\u3000\uff12\uff0e\u6539\u6b63\u5185\u5bb9<br>\u3000\u3000\u3000\u3000\u3000\u3000\u3000\uff08\uff12\uff09\u6c34\u9053\u6cd5\u65bd\u884c\u898f\u5247\u306e\u4e00\u90e8\u3092\u6539\u6b63\u3059\u308b\u7701\u4ee4<br>\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\uff08\u74b0\u6c34\u5927\u7ba1\u767a\u7b2c2506305\u53f7 \u4ee4\u548c7\u5e746\u670830\u65e5 <a href=\"https:\/\/www.env.go.jp\/content\/000325801.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.env.go.jp\/content\/000325801.pdf<\/a>\uff09<\/p>\n\n\n\n<p>\u3000\u3000\u3000\u3000\u3000\u25cePFOS\u53ca\u3073PFOA\u3000\u56fa\u76f8\u62bd\u51fa\u2015\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u2015\u8cea\u91cf\u5206\u6790\u6cd5\u3000\u8cea\u7591\u5fdc\u7b54\u96c6 (Q&amp;A)<br>\u3000\u3000\u3000\u3000\u3000\u3000\u30005\uff0e\u691c\u91cf\u7dda\u306e\u4f5c\u6210<br>\u3000\u3000\u3000\u3000\u3000\u3000\u3000Q5-2\uff09PFOS\u53ca\u3073PFOA\u306e\u5b9a\u91cf\u4e0b\u9650\u306f\u3001\u3069\u306e\u7a0b\u5ea6\u306e\u6fc3\u5ea6\u307e\u3067\u78ba\u8a8d\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u304b\u3002<br>\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\u3000\uff08\u751f\u6d3b\u885b\u751f\u5316\u5b66\u90e8 | \u7b2c3\u5ba4 <a href=\"https:\/\/www.nihs.go.jp\/dec\/section3\/qa\/pfas.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/www.nihs.go.jp\/dec\/section3\/qa\/pfas.html<\/a>\uff09<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u25b8 \u56de\u53ce\u7387\u30fb\u518d\u73fe\u6027\u306e\u62c5\u4fdd<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6a19\u6e96\u6dfb\u52a0\u8a66\u9a13\u3084\u540c\u4f4d\u4f53\u5e0c\u91c8\u6cd5\u306b\u3088\u3063\u3066\u300170\u301c130%\u306e\u56de\u53ce\u7387\u3001\u00b120%\u4ee5\u5185\u306e\u518d\u73fe\u6027\u304c\u56fd\u969b\u7684\u306a\u8a31\u5bb9\u7bc4\u56f2<\/li>\n\n\n\n<li>\u4f7f\u7528\u3059\u308b\u56fa\u76f8\u62bd\u51fa\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\uff08SPE\uff09\u3001\u308d\u904e\u6750\u3001\u4fdd\u5b58\u5bb9\u5668\u306a\u3069\u3082PFAS\u30d5\u30ea\u30fc\u3067\u3042\u308b\u3053\u3068\u304c\u5fc5\u9808<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u25b8 \u4f7f\u7528\u3059\u3079\u304d\u5206\u6790\u624b\u6cd5\u306e\u4f8b<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u524d\u51e6\u7406\uff1a<\/strong>WAX\uff08\u5f31\u9670\u30a4\u30aa\u30f3\u4ea4\u63db\uff09SPE\u304c\u4e00\u822c\u7684\u3002\u5e02\u8ca9\u306e\u5c02\u7528\u30ab\u30fc\u30c8\u30ea\u30c3\u30b8\uff08\u4f8b\uff1aResprep WAX\uff09\u4f7f\u7528<\/li>\n\n\n\n<li><strong>\u5206\u6790\u88c5\u7f6e\uff1a<\/strong>LC-MS\/MS\uff08\u30c8\u30ea\u30d7\u30eb\u56db\u91cd\u6975\u578b\uff09\u306b\u3088\u308b\u9ad8\u9078\u629e\u6027\u691c\u51fa<\/li>\n\n\n\n<li><strong>\u5206\u6790\u30e1\u30bd\u30c3\u30c9\uff1a<\/strong>\u7c73\u56fdEPA Method 533\uff08\u77ed\u9396\uff5e\u9577\u9396PFAS\u5bfe\u5fdc\uff09\u304c\u3001\u65e5\u672c\u306e\u6c34\u9053\u57fa\u6e96\u306b\u3082\u6574\u5408\u6027\u3042\u308a<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">\u25b8 \u30b3\u30f3\u30bf\u30df\u5bfe\u7b56\u30fb\u5206\u6790\u74b0\u5883\u306e\u7ba1\u7406<\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u88c5\u7f6e\u69cb\u6210\uff08Delay Column\u306e\u4f7f\u7528\u306a\u3069\uff09\u306b\u3088\u308bPFAS\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u306e\u6291\u5236<\/li>\n\n\n\n<li>\u5bb9\u5668\u30fb\u30c1\u30e5\u30fc\u30d6\u30fb\u30dd\u30f3\u30d7\u985e\u3059\u3079\u3066\u306b\u304a\u3044\u3066\u3001PTFE\u3001PVDF\u306a\u3069PFAS\u542b\u6709\u7d20\u6750\u306e\u4e0d\u4f7f\u7528\u3092\u5fb9\u5e95<\/li>\n\n\n\n<li>\u5206\u6790\u74b0\u5883\uff08\u8a66\u85ac\u68da\u3001\u524d\u51e6\u7406\u53f0\u306a\u3069\uff09\u306e\u6e05\u6d44\u5ea6\u7ba1\u7406\u3068\u5b9a\u671f\u7684\u306a\u7a7a\u30d6\u30e9\u30f3\u30af\u6e2c\u5b9a\u306e\u5b9f\u65bd<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">\u25a0\u3000\u5206\u6790\u5bfe\u5fdc\u306b\u5411\u3051\u305f\u5b9f\u52d9\u4e0a\u306e\u7559\u610f\u70b9<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><thead><tr><th>\u9805\u76ee<\/th><th>\u5185\u5bb9<\/th><\/tr><\/thead><tbody><tr><td>\u5b9a\u91cf\u4e0b\u9650\u306e\u78ba\u4fdd<\/td><td>\u57fa\u6e96\u5024\u304c\u6975\u3081\u3066\u4f4e\u6fc3\u5ea6\uff0850 ng\/L\uff09\u3067\u3042\u308b\u305f\u3081\u3001\u5206\u6790\u6a5f\u5668\u306e\u6027\u80fd\u3060\u3051\u3067\u306a\u304f\u3001\u524d\u51e6\u7406\u65b9\u6cd5\u3001\u6fc3\u7e2e\u52b9\u7387\u3001\u30ed\u30b9\u524a\u6e1b\u306a\u3069\u306e\u5de5\u592b\u304c\u4e0d\u53ef\u6b20<\/td><\/tr><tr><td>\u30d6\u30e9\u30f3\u30af\u6c5a\u67d3\u5bfe\u7b56<\/td><td>PFAS \u306f\u591a\u304f\u306e\u5206\u6790\u6a5f\u6750\u30fb\u6d88\u8017\u54c1\u30fb\u30b5\u30f3\u30d7\u30ea\u30f3\u30b0\u6a5f\u6750\u306b\u542b\u307e\u308c\u5f97\u308b\u305f\u3081\u3001\u975e\u542b\u6709\u6750\u306e\u9078\u5b9a\u3084\u5fb9\u5e95\u3057\u305f\u6d17\u6d44\u30fb\u30b3\u30f3\u30bf\u30df\u5bfe\u7b56\u304c\u5fc5\u9808<\/td><\/tr><tr><td>\u6a19\u6e96\u7269\u8cea\u306e\u9078\u5b9a<\/td><td>\u5b9a\u91cf\u7cbe\u5ea6\u306e\u78ba\u4fdd\u306b\u306f\u3001\u5b89\u5b9a\u540c\u4f4d\u4f53\u6a19\u8b58\u5316\u5408\u7269\uff08IS\uff09\u3001\u8a8d\u8a3c\u6a19\u6e96\u7269\u8cea\uff08CRM\uff09\u306e\u4f7f\u7528\u304c\u5f37\u304f\u63a8\u5968\u3055\u308c\u308b<\/td><\/tr><tr><td>\u4eca\u5f8c\u306e\u898f\u5236\u62e1\u5927\u306b\u5099\u3048\u305f\u5206\u6790\u5bfe\u8c61\u306e\u62e1\u5145<\/td><td>PFHxS\u3084GenX\u306a\u3069\u3001\u4ed6\u306ePFAS\u5316\u5408\u7269\u3078\u306e\u898f\u5236\u304c\u5c06\u6765\u7684\u306b\u62e1\u5927\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u5305\u62ec\u7684\u306aPFAS\u5206\u6790\u624b\u6cd5\uff08\u4f8b\uff1aEPA Method 533\u5bfe\u5fdc\uff09\u306e\u6574\u5099\u304c\u671b\u307e\u3057\u3044<\/td><\/tr><tr><td>\u5bfe\u7b56\u6280\u8853\u30fb\u30b3\u30b9\u30c8\u8a55\u4fa1<\/td><td>\u8d85\u904e\u6642\u306e\u662f\u6b63\u63aa\u7f6e\uff08\u9664\u53bb\u6280\u8853\u5c0e\u5165\u30fb\u6e90\u8abf\u67fb\u7b49\uff09\u306e\u6280\u8853\u7684\u3001\u7d4c\u6e08\u7684\u30a4\u30f3\u30d1\u30af\u30c8\u3092\u4e8b\u524d\u306b\u8a55\u4fa1\u3057\u3066\u304a\u304f\u5fc5\u8981\u3042\u308a<\/td><\/tr><tr><td>\u56fd\u969b\u7684\u5206\u6790\u6cd5\u3068\u306e\u6574\u5408<\/td><td>\u7c73\u56fdEPA\u3001\u6b27\u5ddeECHA\u306a\u3069\u304c\u5b9a\u3081\u308bPFAS\u5206\u6790\u624b\u6cd5\u3068\u306e\u6574\u5408\u6027\u3092\u6301\u3063\u305f\u30e1\u30bd\u30c3\u30c9\uff08\u4f8b\uff1aEPA 533\uff09\u3092\u5c0e\u5165\u3059\u308b\u3053\u3068\u3067\u3001\u30b0\u30ed\u30fc\u30d0\u30eb\u4fe1\u983c\u6027\u3092\u78ba\u4fdd\u53ef\u80fd<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u25a0\u3000\u5206\u6790\u4e0a\u306e\u554f\u984c\u70b9\uff08\u30b3\u30f3\u30bf\u30df\u30cd\u30fc\u30b7\u30e7\u30f3\uff09\u3078\u306e\u5bfe\u5fdc\u4f8b\u3000<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table style=\"border-width:1px\"><tbody><tr><td><a href=\"https:\/\/cfpub.epa.gov\/si\/si_public_file_download.cfm?p_download_id=537290&amp;Lab=NERL\" target=\"_blank\" rel=\"noreferrer noopener\">EPA METHOD 537.1<\/a><\/td><td>\u6d17\u5264\u3068\u6c34\u9053\u6c34\u3067\u30ac\u30e9\u30b9\u5668\u5177\u3092\u6d17\u3044\u3001\u6c34\u9053\u6c34\u3067\u3059\u3059\u304e\u3001\u305d\u306e\u5f8c\u8a66\u85ac\u6c34\u3067\u3059\u3059\u3050\u3002\u6e05\u6f54\u306a\u30ac\u30e9\u30b9\u5668\u5177\u306f\u3001\u9006\u3055\u307e\u306b\u3059\u308b\u304b\u3001\u84cb\u3092\u3057\u3066\u4fdd\u7ba1\u3059\u308b\u3002\u30a2\u30eb\u30df\u30db\u30a4\u30eb\u3067\u8986\u308f\u306a\u3044\u3088\u3046\u306b\u3059\u308b\u3002PFAS\u304c\u30a2\u30eb\u30df\u30db\u30a4\u30eb\u304b\u3089\u30ac\u30e9\u30b9\u5668\u5177\u306b\u79fb\u884c\u3059\u308b\u53ef\u80fd\u6027\u3042\u308a\u3002<\/td><\/tr><tr><td><a href=\"https:\/\/www.env.go.jp\/content\/000378233.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u6c34\u8cea\u57fa\u6e96\u306b\u95a2\u3059\u308b\u7701\u4ee4\u306e\u898f\u5b9a\u306b\u57fa\u3065\u304d\u74b0\u5883\u5927\u81e3\u304c\u5b9a\u3081\u308b\u65b9\u6cd5\uff08\u5e73\u621015\u5e74\u539a\u751f\u52b4\u50cd\u7701\u544a\u793a \u7b2c261\u53f7\uff09\u3000\u5225\u8868\u7b2c45<\/a><\/td><td><strong>\u8a66\u9a13\u64cd\u4f5c\u4e2d\u306bPFOS\u3001PFOA\u53ca\u3073PFHxS\u304c\u6eb6\u51fa\u3057\u3001\u6a19\u6e96\u6db2\u53ca\u3073\u8a66\u6599\u306b\u6df7\u5165\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u4e8b\u524d\u306b\u4ee5\u4e0b\u306e\u51e6\u7406\u3092\u884c\u3044\u3001\u4f7f\u7528\u3059\u308b\u5668\u5177\u3084\u88c5\u7f6e\u304c\u691c\u67fb\u7d50\u679c\u306b\u5f71\u97ff\u3092\u53ca\u307c\u3055\u306a\u3044\u3053\u3068\u3092\u5341\u5206\u306b\u78ba\u8a8d\u3059\u308b\u3053\u3068\u304c\u5fc5\u8981\u3002<\/strong><br><br><strong>\uff16 \u7a7a\u8a66\u9a13<\/strong>\u3000\u7cbe\u88fd\u6c34\u3092\u4e00\u5b9a\u91cf\u63a1\u308a\u3001\u4ee5\u4e0b\u4e0a\u8a18\uff14(1)\u53ca\u3073(2)\u540c\u69d8\u306b\u64cd\u4f5c\u3057\u3066\u8a66\u9a13\u6eb6\u6db2\u4e2d\u306e\uff30\uff26\uff2f\uff33\u53ca\u3073\uff30\uff26\uff2f\uff21\u306e\u6fc3\u5ea6\u3092\u6c42\u3081\u3001\u691c\u91cf\u7dda\u306e\u6fc3\u5ea6\u7bc4\u56f2\u306e\u4e0b\u9650\u5024\u3092\u4e0b\u56de\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3059\u308b\u3002<br>\u6c42\u3081\u3089\u308c\u305f\u6fc3\u5ea6\u304c\u5f53\u8a72\u6fc3\u5ea6\u7bc4\u56f2\u306e\u4e0b\u9650\u5024\u4ee5\u4e0a\u306e\u5834\u5408\u306f\u3001\u662f\u6b63\u51e6\u7f6e\u3092\u8b1b\u3058\u305f\u4e0a\u3067\u4e0a\u8a18\uff14\u2474\u53ca\u3073\u2475\u3068\u540c\u69d8\u306e\u64cd\u4f5c\u3092\u518d\u3073\u884c\u3044\u3001\u6c42\u3081\u3089\u308c\u305f\u6fc3\u5ea6\u304c\u5f53\u8a72\u6fc3\u5ea6\u7bc4\u56f2\u306e\u4e0b\u9650\u5024\u3092\u4e0b\u56de\u308b\u307e\u3067\u64cd\u4f5c\u3092\u7e70\u308a\u8fd4\u3059\u3002<br><strong>\u5099\u8003\uff11<\/strong>\u3000\u5168\u3066\u306e\u64cd\u4f5c\u306b\u304a\u3044\u3066\u3001\u6a19\u6e96\u6db2\u53ca\u3073\u8a66\u6599\u3068\u89e6\u308c\u308b\u90e8\u5206\u306b\u30dd\u30ea\u30c6\u30c8\u30e9\u30d5\u30eb\u30aa\u30ed\u30a8\u30c1\u30ec\u30f3\u304c\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u5bb9\u5668\u3092\u7528\u3044\u306a\u3044\u3053\u3068\u3002<\/td><\/tr><tr><td><a href=\"https:\/\/www.nihs.go.jp\/dec\/section3\/manual\/pfas.html\" target=\"_blank\" rel=\"noopener\">\u56fa\u76f8\u62bd\u51fa\u30fc\u6db2\u4f53\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30fc\u8cea\u91cf\u5206\u6790\u6cd5\u30007\uff0e\u7559\u610f\u70b9\uff08\u539a\u751f\u52b4\u50cd\u7701 PFOS\u30fbPFOA\u30fbPFHxS\u691c\u67fb\u30de\u30cb\u30e5\u30a2\u30eb\uff09<\/a><\/td><td>\u5168\u3066\u306e\u64cd\u4f5c\u306b\u304a\u3044\u3066\u3001\u6a19\u6e96\u6db2\u53ca\u3073\u8a66\u6599\u3068\u89e6\u308c\u308b\u90e8\u5206\u306b\u30dd\u30ea\u30c6\u30c8\u30e9\u30d5\u30eb\u30aa\u30ed\u30a8\u30c1\u30ec\u30f3\u304c\u4f7f\u7528\u3055\u308c\u3066\u3044\u308b\u5bb9\u5668\u3092\u7528\u3044\u306a\u3044\u3053\u3068\u3002<\/td><\/tr><tr><td><a href=\"https:\/\/www.env.go.jp\/content\/900515658.pdf\" target=\"_blank\" rel=\"noreferrer noopener\">\u6c34\u8cea\u6c5a\u6fc1\u306b\u4fc2\u308b\u4eba\u306e\u5065\u5eb7\u306e\u4fdd\u8b77\u306b\u95a2\u3059\u308b\u74b0\u5883\u57fa\u6e96\u7b49\u306e\u65bd\u884c\u7b49\u306b\u3064\u3044\u3066\uff08\u901a\u77e5\uff09<\/a><\/td><td>PFOS\u53ca\u3073PFOA\u306f\u30d5\u30c3\u7d20\u6a39\u8102\u52a0\u5de5\u3055\u308c\u305f\u5668\u5177\u7b49\u304b\u3089\u6eb6\u51fa\u3059\u308b\u53ef\u80fd\u6027\u304c\u3042\u308b\u305f\u3081\u3001\u3053\u308c\u3089\u306e\u5668\u5177\u306f\u53ef\u80fd\u306a\u9650\u308a\u4f7f\u7528\u3057\u306a\u3044\u3002\u307e\u305f\u3001\u4f7f\u7528\u3059\u308b\u5668\u5177\u7b49\u306f\u30e1\u30bf\u30ce\u30fc\u30eb\u3067\u5145\u5206\u6d17\u6d44\u3057\u3001\u5bfe\u8c61\u7269\u8cea\u306e\u30d4\u30fc\u30af\u304c\u51fa\u306a\u3044\u3053\u3068\u3092\u78ba\u8a8d\u3057\u3066\u4f7f\u7528\u3059\u308b\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u3067\u306f\u3001\u79c1\u305f\u3061Restek\u304c\u3067\u304d\u308b\u3053\u3068\u3092\u6700\u7d42\u56de\u306e<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-05\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-5-ja\/\" target=\"_blank\" data-type=\"link\" data-id=\"https:\/\/discover.restek.com\/ja\/articles-ja\/JPSA2025-05\/strengthened-pfos-and-pfoa-regulations-prepare-for-the-water-supply-act-revision-now-resteks-complete-guide-to-pfas-analysis-part-5-ja\/\" rel=\"noreferrer noopener\">\u7b2c5\u56de\uff1aPFAS\u5206\u6790\u3092\u652f\u3048\u308bRestek\u88fd\u54c1\u3068\u6700\u65b0\u30e1\u30bd\u30c3\u30c9\u306e\u5c0e\u5165\u4e8b\u4f8b<\/a>\u3067\u3054\u7d39\u4ecb\u3057\u305f\u3044\u3068\u601d\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>2026\u5e74\u65bd\u884c\u306e\u6c34\u9053\u6cd5\u6539\u6b63\u306b\u3088\u308a\u3001PFOS\u30fbPFOA\u306e\u898f\u5236\u304c\u5f37\u5316\u3002PFAS\u5206\u6790\u306b\u5fc5\u8981\u306a\u30ea\u30b9\u30af\u7406\u89e3\u3084\u6c34\u8cea\u57fa\u6e96\u306e\u80cc\u666f\u3092\u74b0\u5883\u7701\u306e\u8cc7\u6599\u3092\u53c2\u7167\u3057\u3064\u3064\u3001\u5c02\u9580\u7684\u8996\u70b9\u304b\u3089\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":0,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[789],"tags":[2761],"industries-application":[2288,2271,2287],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-71851","post","type-post","status-publish","format-standard","hentry","category-articles-ja","tag-ja-only","industries-application-pfas-testing-ja","industries-application-environmental-ja","industries-application-drinking-water-wastewater-testing-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2761,"label":"JA-Only"}],"industries-application":[{"value":2288,"label":"PFAS \u5206\u6790"},{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"},{"value":2287,"label":"\u98f2\u6599\u6c34\uff5c\u975e\u98f2\u6599\u6c34\uff5c\u6392\u6c34 \u5206\u6790"}]},"featured_image_src_large":false,"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":459,"filter":"raw","cat_ID":789,"category_count":459,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2761,"name":"JA-Only","slug":"ja-only","term_group":0,"term_taxonomy_id":2761,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw"}],"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71851","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=71851"}],"version-history":[{"count":8,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71851\/revisions"}],"predecessor-version":[{"id":96008,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/71851\/revisions\/96008"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=71851"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=71851"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=71851"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=71851"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=71851"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=71851"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=71851"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=71851"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=71851"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}