{"id":72510,"date":"2025-11-18T16:29:58","date_gmt":"2025-11-18T16:29:58","guid":{"rendered":"https:\/\/discover.restek.com\/?p=72510"},"modified":"2026-02-20T06:54:05","modified_gmt":"2026-02-20T06:54:05","slug":"alcoholic-beverage-analysis-by-gc-increase-accuracy-with-rtx-1301-column-selectivity","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/ffar4494-ja\/alcoholic-beverage-analysis-by-gc-increase-accuracy-with-rtx-1301-column-selectivity","title":{"rendered":"\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306e\u63ee\u767a\u6027\u6210\u5206\u3092\u89e3\u6790\u3059\u308b\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},"content":{"rendered":"\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306e\u63ee\u767a\u6027\u6210\u5206\u3068GC\u5206\u6790\u306e\u91cd\u8981\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306b\u542b\u307e\u308c\u308b\u63ee\u767a\u6027\u6210\u5206\u306e\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306f\u3001\u9178\u985e\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u985e\u3001\u30a2\u30eb\u30c7\u30d2\u30c9\u985e\u3001\u305d\u3057\u3066\u5fae\u91cf\u306a\u304c\u3089\u9999\u308a\u3084\u5473\u308f\u3044\u306b\u5927\u304d\u304f\u5f71\u97ff\u3059\u308b\u305d\u306e\u4ed6\u306e\u30d5\u30ec\u30fc\u30d0\u30fc\u5316\u5408\u7269\u306a\u3069\u3001\u591a\u69d8\u306a\u6210\u5206\u304b\u3089\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u84b8\u7559\u9152\u3001\u30ef\u30a4\u30f3\u3001\u30d3\u30fc\u30eb\u306e\u5b98\u80fd\u8a55\u4fa1\u306b\u7cbe\u901a\u3057\u305f\u5c02\u9580\u5bb6\u306f\u3001\u540c\u3058\u88fd\u54c1\u304c\u4e8c\u3064\u3068\u3057\u3066\u5b58\u5728\u3057\u306a\u3044\u3068\u3088\u304f\u6307\u6458\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u305d\u308c\u305e\u308c\u306e\u98f2\u6599\u306b\u542b\u307e\u308c\u308b\u63ee\u767a\u6027\u6210\u5206\u306e\u308f\u305a\u304b\u306a\u5dee\u7570\u304c\u3001\u500b\u3005\u306e\u72ec\u81ea\u6027\u3092\u751f\u307f\u51fa\u3057\u3066\u3044\u308b\u305f\u3081\u3067\u3059\u3002<br>\u3053\u308c\u3089\u306e\u9055\u3044\u3092\u7406\u89e3\u3059\u308b\u306b\u306f\u3001\u5b98\u80fd\u8a55\u4fa1\u306b\u52a0\u3048\u3066\u3001\u6a5f\u5668\u5206\u6790\u306b\u3088\u308b\u5b9a\u6027\u7684\u30fb\u5b9a\u91cf\u7684\u8a55\u4fa1\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u54c1\u8cea\u4fdd\u8a3c\uff08QA\uff09\u306e\u62c5\u5f53\u8005\u306f\u3001\u4e21\u8005\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u88fd\u54c1\u306e\u7279\u6027\u306b\u3064\u3044\u3066\u3088\u308a\u5305\u62ec\u7684\u306a\u60c5\u5831\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0;line-height:1.5\">\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u306f\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u975e\u5e38\u306b\u5f37\u529b\u306a\u30c4\u30fc\u30eb\u3067\u3059\u304c\u3001\u540c\u6642\u306b\u6271\u3044\u3084\u3059\u3044\u5206\u6790\u624b\u6cd5\u3067\u3082\u3042\u308a\u307e\u3059\u3002\u7406\u7531\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001\u3053\u3046\u3057\u305fGC\u306e\u7279\u6027\u3092\u8e0f\u307e\u3048\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u4e2d\u306b\u542b\u307e\u308c\u308b\u63ee\u767a\u6027\u6210\u5206\u3092\u3069\u306e\u3088\u3046\u306b\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3067\u304d\u308b\u304b\u306b\u3064\u3044\u3066\u3001\u305d\u306e\u5206\u6790\u624b\u6cd5\u3068\u5fdc\u7528\u4f8b\u3092\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ul style=\"margin-right:var(--wp--preset--spacing--60);margin-left:var(--wp--preset--spacing--60)\" class=\"wp-block-list\">\n<li style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\">\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u304c\u307b\u3068\u3093\u3069\u4e0d\u8981\uff1a \u30a2\u30eb\u30b3\u30fc\u30eb\u307e\u305f\u306f\u30a2\u30eb\u30b3\u30fc\u30eb\uff0f\u6c34\u6df7\u5408\u6db2\u3092\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3068\u3057\u3066\u3001\u305d\u306e\u307e\u307e\u6db2\u4f53\u306e\u72b6\u614b\u3067\u5206\u6790\u53ef\u80fd<\/li>\n\n\n\n<li style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\">\u30d5\u30ec\u30fc\u30d0\u30fc\u6210\u5206\u306f\u63ee\u767a\u6027\u304c\u9ad8\u3044\uff1aGC\u5206\u6790\u306b\u9069\u3057\u3066\u304a\u308a\u3001\u5927\u304d\u306a\u5229\u70b9<\/li>\n\n\n\n<li style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\">\u4e00\u822c\u7684\u306a\u691c\u51fa\u5668\uff08\u6c34\u7d20\u708e\u30a4\u30aa\u30f3\u5316\u691c\u51fa\u5668\u3001FID\uff09\u304b\u3089\u3001\u3088\u308a\u60c5\u5831\u91cf\u306e\u591a\u3044\u8cea\u91cf\u9078\u629e\u6027\u691c\u51fa\u5668\uff08MSD\uff09\u307e\u3067\u5229\u7528\u53ef\u80fd<\/li>\n\n\n\n<li style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\">\u81ea\u52d5\u5316\u304c\u5bb9\u6613\u3067\u3001QA\/\u54c1\u8cea\u7ba1\u7406\uff08QC\uff09\u306e\u73fe\u5834\u3067\u7279\u306b\u6709\u7528<\/li>\n<\/ul>\n<\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u4e2d\u306e\u30a2\u30eb\u30b3\u30fc\u30eb\u304a\u3088\u3073\u30a2\u30eb\u30c7\u30d2\u30c9\u306e\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306b\u306f\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u985e\u3084\u77ed\u9396\u30a2\u30eb\u30c7\u30d2\u30c9\u3092\u306f\u3058\u3081\u3068\u3059\u308b\u591a\u69d8\u306a\u63ee\u767a\u6027\u5316\u5408\u7269\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002GC\u306f\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u3092\u3001\u30b5\u30f3\u30d7\u30eb\u62bd\u51fa\u3092\u884c\u308f\u305a\u306b\u76f4\u63a5\u5206\u6790\u3067\u304d\u308b\u70b9\u3067\u975e\u5e38\u306b\u6709\u52b9\u3067\u3059\u3002AOAC International\u3067\u3082\u3001\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\uff08\u30d5\u30fc\u30bc\u30eb\u6cb9\u3068\u3082\u547c\u3070\u308c\u308b\uff09\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3001\u3055\u3089\u306b\u306f\u9ad8\u6b21\u30a2\u30eb\u30b3\u30fc\u30eb\u306e\u5206\u6790\u6cd5\u304cGC\u3092\u7528\u3044\u305f\u624b\u6cd5\u3068\u3057\u3066\u516c\u8868\u3055\u308c\u3066\u3044\u307e\u3059\uff3b1\uff3d\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306f\u9ad8\u3044\u5206\u96e2\u52b9\u7387\u3092\u5099\u3048\u3066\u304a\u308a\u3001\u7279\u306b\u69cb\u9020\u304c\u985e\u4f3c\u3057\u305f\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u985e\u306e\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5e45\u5e83\u3044\u30a2\u30eb\u30b3\u30fc\u30eb\u306b\u3064\u3044\u3066\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u9069\u5207\u306a\u5206\u96e2\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u5206\u6790\u5bfe\u8c61\u306b\u5408\u3063\u305f\u9078\u629e\u6027\u3092\u3082\u3064\u56fa\u5b9a\u76f8\u3092\u9078\u3076\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u4e3b\u8981\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u3067\u3042\u308b 2-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\uff08\u30a4\u30bd\u30a2\u30df\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\uff09\u3068 3-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\uff08\u6d3b\u6027\u30a2\u30df\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\uff09\u306e\u5206\u96e2\u306f\u3001\u6b63\u78ba\u306a\u5206\u6790\u306e\u305f\u3081\u306b\u5fc5\u9808\u306e\u30dd\u30a4\u30f3\u30c8\u3067\u3059\u3002<br>\u307e\u305f\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306f\u6c34\u3068\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u4e3b\u4f53\u3068\u3059\u308b\u305f\u3081\u3001\u6c34\u3001\u30a2\u30bb\u30c8\u30a2\u30eb\u30c7\u30d2\u30c9\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3068\u3044\u3063\u305f\u6210\u5206\u3092\u3057\u3063\u304b\u308a\u3068\u5206\u96e2\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u304c\u5171\u6eb6\u51fa\u3059\u308b\u3068\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c\u3084\u5fae\u91cf\u6210\u5206\u306e\u30d4\u30fc\u30af\u304c\u4e3b\u8981\u30d4\u30fc\u30af\u306b\u57cb\u3082\u308c\u308b\u3053\u3068\u3067\u3001\u6b63\u78ba\u306a\u5b9a\u91cf\u304c\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002\u52a0\u3048\u3066\u3001\u9162\u9178\u306f\u56fa\u5b9a\u76f8\u3068\u306e\u76f8\u6027\u306b\u3088\u3063\u3066\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u4e71\u308c\u3084\u3059\u304f\u3001\u5206\u6790\u4e0a\u306e\u6ce8\u610f\u70b9\u3068\u3057\u3066\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table class=\"has-theme-palette-8-background-color has-background has-fixed-layout\"><tbody><tr><td><strong>Tech Tip\uff08\u6280\u8853\u7684\u306a\u30d2\u30f3\u30c8\uff09<\/strong><br>\u30a8\u30bf\u30ce\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u3092\u6271\u3046\u969b\u306f\u3001\u30b7\u30ea\u30f3\u30b8\u306e\u5bff\u547d\u3092\u6700\u5927\u9650\u306b\u5ef6\u3070\u3059\u305f\u3081\u306b\u3001\u6c17\u5bc6\u6027\u306e\u9ad8\u3044\u30ac\u30b9\u30b7\u30ea\u30f3\u30b8\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u9069\u5207\u306a\u9078\u629e\u6027\u3092\u6301\u3064GC\u30ab\u30e9\u30e0\u306e\u9078\u629e<\/h2>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<p class=\"wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306eGC\u5206\u6790\u306b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3092\u9078\u5b9a\u3059\u308b\u305f\u3081\u3001\u6975\u6027\u306e\u7570\u306a\u308b3\u7a2e\u985e\u306e\u56fa\u5b9a\u76f8\u304c\u6bd4\u8f03\u8a55\u4fa1\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<ul style=\"margin-top:0;margin-bottom:0\" class=\"wp-block-list\">\n<li class=\"has-theme-palette-2-color has-text-color has-link-color wp-elements-1\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\">Rtx-VMS\uff08\u6eb6\u5a92\u304a\u3088\u3073\u63ee\u767a\u6027\u5316\u5408\u7269\u306b\u5bfe\u3059\u308b\u72ec\u81ea\u306e\u6975\u6027\uff09<\/li>\n\n\n\n<li class=\"has-theme-palette-2-color has-text-color has-link-color wp-elements-2\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\">Rtx-502.2\uff08\u4f4e\u6975\u6027\uff09<\/li>\n\n\n\n<li class=\"has-theme-palette-2-color has-text-color has-link-color wp-elements-3\" style=\"margin-top:0;margin-right:0;margin-bottom:0;margin-left:0\">Rtx-1301\uff08\u4e2d\u6975\u6027\uff09<\/li>\n<\/ul>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u8a55\u4fa1\u306b\u3042\u305f\u3063\u3066\u306f\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u826f\u5426\u3068\u4e3b\u8981\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306e\u5206\u96e2\u5ea6\u3092\u4e3b\u8981\u306a\u8a55\u4fa1\u6307\u6a19\u3068\u3057\u307e\u3057\u305f\u3002\u307e\u305a\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u5206\u6790\u3067\u4e00\u822c\u7684\u306b\u30c6\u30b9\u30c8\u3055\u308c\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3092\u542b\u3080\u6a19\u6e96\u8a66\u6599\u3092\u30a8\u30bf\u30ce\u30fc\u30eb\u4e2d 100 \u00b5g\/mL\u3067\u8abf\u88fd\u3057\u3001\u521d\u671f\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3092FID\u3067\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u306e\u5f8c\u3001\u30d5\u30eb\u30b9\u30ad\u30e3\u30f3\u6cd5\uff0810\u2013400 m\/z\uff09\u3092\u7528\u3044\u3066MSD\u5206\u6790\u3092\u5b9f\u65bd\u3057\u3001\u6c34\u304c\u5341\u5206\u306b\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"margin-top:-10px;margin-bottom:-10px\">\u3044\u305a\u308c\u306e\u56fa\u5b9a\u76f8\u3082\u3001\u6c34\u3001\u30a2\u30bb\u30c8\u30a2\u30eb\u30c7\u30d2\u30c9\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u3064\u3044\u3066\u306f\u826f\u597d\u306a\u5206\u96e2\u3092\u793a\u3057\u307e\u3057\u305f\u3002<strong>Figure 1<\/strong>\u306eRtx-1301\u30ab\u30e9\u30e0\u306b\u3088\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u3001\u3053\u308c\u3089\u5316\u5408\u7269\u306e\u5178\u578b\u7684\u306a\u5206\u96e2\u4f8b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 1:<\/strong> GC-MS\u3092\u4f7f\u7528\u3057\u305fRtx-1301\u30ab\u30e9\u30e0\u3067\u306e\u6c34\/\u30a2\u30bb\u30c8\u30a2\u30eb\u30c7\u30d2\u30c9\u306e\u5178\u578b\u7684\u306a\u5206\u96e2\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1389.png\" alt=\"Rtx-1301 Water, Acetaldehyde, and Methanol Separation\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1389<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16056<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1389.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<figure class=\"wp-block-table\">\n<table style=\"background-color:#E6DEDB; border: none;\">\n<tbody>\n<tr style=\"border: none;\">\n<td style=\"width=75%; border: none;\"><strong>\u3054\u5b58\u77e5\u3067\u3057\u305f\u304b&nbsp;?<\/strong><br>\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u306f\u9ad8\u6b21\uff08\u3059\u306a\u308f\u3061\u4e8c\u7d1a\u307e\u305f\u306f\u4e09\u7d1a\uff09\u30a2\u30eb\u30b3\u30fc\u30eb\u3067\u3042\u308a\u3001\u30d3\u30fc\u30eb\u306b\u306f\u901a\u5e38\u5fae\u91cf\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u306f\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3068\u985e\u4f3c\u306e\u751f\u6210\u7d4c\u8def\u3092\u7d4c\u3066\u751f\u6210\u3055\u308c\u3001\u8f9b\u5473\u3084\u30b9\u30d1\u30a4\u30b7\u30fc\u3055\u3001\u6eb6\u5a92\u81ed\u306e\u3088\u3046\u306a\u98a8\u5473\u3001\u3044\u308f\u3086\u308b\u30a2\u30eb\u30b3\u30fc\u30eb\u306e\u300c\u523a\u6fc0\u611f\u300d\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002\u30b9\u30c8\u30ed\u30f3\u30b0\u30a8\u30fc\u30eb\u3084\u30d0\u30fc\u30ec\u30a4\u30ef\u30a4\u30f3\u306a\u3069\u3001\u30b9\u30bf\u30a4\u30eb\u306b\u3088\u3063\u3066\u306f\u5c11\u91cf\u306a\u3089\u597d\u307e\u3057\u3044\u98a8\u5473\u3068\u306a\u308a\u307e\u3059\u304c\u3001\u30d4\u30eb\u30b9\u30ca\u30fc\u306a\u3069\u306e\u30e9\u30ac\u30fc\u3067\u306f\u4e0d\u5feb\u306a\u5473\u306b\u3064\u306a\u304c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u306f\u9175\u6bcd\u306b\u3068\u3063\u3066\u306f\u6709\u5bb3\u3067\u3042\u308b\u305f\u3081\u3001\u30dc\u30c8\u30eb\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30f3\u306e\u30d3\u30fc\u30eb\u3067\u306f\u70ad\u9178\u4fdd\u6301\u6027\u3084\u6ce1\u306e\u4fdd\u6301\u529b\u306e\u4f4e\u4e0b\u3092\u62db\u304f\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u767a\u9175\u6e29\u5ea6\u304c\u9ad8\u3044\u3068\u3001\u9175\u6bcd\u306e\u6210\u9577\u304c\u904e\u5270\u306b\u65e9\u307e\u308a\u3001\u7a81\u7136\u5909\u7570\u304c\u8d77\u3053\u308a\u3084\u3059\u304f\u306a\u308b\u305f\u3081\u3001\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u306e\u751f\u6210\u304c\u4fc3\u9032\u3055\u308c\u307e\u3059\u3002<\/td>\n<td style=\"width:25%; border: none;\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/teaser-article-FFAR4494-01.jpg\" alt=\"picture of beer bottles\" width=\"250\" height=\"165\" title=\"-\"><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\">\u56fa\u5b9a\u76f8\u306e\u8a73\u7d30\u691c\u8a0e\u3067\u306f\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<ul style=\"margin-top:-10px;margin-bottom:-10px\" class=\"wp-block-list\">\n<li class=\"has-theme-palette-5-color has-text-color has-link-color wp-elements-4\" style=\"margin-top:-20px;margin-bottom:-20px\"><strong>Rtx-VMS\u3000\u30ab\u30e9\u30e0\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1a30 m\u00d70.25 mm ID\u00d71.40 \u00b5m\uff08cat.# <a href=\"https:\/\/restek.com\/p\/19915\" data-type=\"link\" data-id=\"https:\/\/restek.com\/p\/19915\" target=\"_blank\" rel=\"noopener\">19915<\/a>\uff09<\/strong>\uff1a\u6c34\u3001\u30a2\u30bb\u30c8\u30a2\u30eb\u30c7\u30d2\u30c9\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u306e\u5206\u96e2\u306f\u826f\u597d\uff08Rtx-1301\u30ab\u30e9\u30e0\u3068\u540c\u69d8\uff09\u3067\u3057\u305f\u304c\u3001\u91cd\u8981\u306a\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u3067\u3042\u308b2-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb \uff08\u30a4\u30bd\u30a2\u30df\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\uff09\u30683-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\uff08\u6d3b\u6027\u30a2\u30df\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\uff09\uff08<strong>Figure 2<\/strong>\u53c2\u7167\uff09\u306f\u5206\u96e2\u3067\u304d\u307e\u305b\u3093\u3067\u3057\u305f\u3002\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u3092 35\u2103 \u3067\u7b49\u6e29\u4fdd\u6301\u3057\u3066\u3082\u3001\u3053\u308c\u3089\u306e\u30a2\u30df\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u306f\u3001\u30ab\u30e9\u30e0\u5bf8\u6cd5\u306b\u95a2\u4fc2\u306a\u304f\u5171\u6eb6\u51fa\u304c\u6539\u5584\u3055\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u3002<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 2:<\/strong> \u4e00\u822c\u7684\u306a\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3067\u3042\u308b2-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\u30683-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\u306f\u3001Rtx-VMS\u30ab\u30e9\u30e0\u3067\u306f\u5206\u96e2\u3055\u308c\u306a\u304b\u3063\u305f\uff08\u30d4\u30fc\u30af12\u304a\u3088\u307313\uff09\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1385.png\" alt=\"Custom Beverage Analysis Mix on Rtx-VMS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1385<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>19915<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1385.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<ul style=\"margin-top:-10px;margin-bottom:-10px\" class=\"wp-block-list\">\n<li class=\"has-theme-palette-5-color has-text-color has-link-color wp-elements-5\" style=\"margin-top:-20px;margin-bottom:-20px\"><strong>Rtx-502.2\u3000\u30ab\u30e9\u30e0\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1a60 m \u00d7 0.25 mm ID \u00d7 1.40 \u00b5m\u3001\uff08cat.# <a href=\"https:\/\/restek.com\/p\/10916\" target=\"_blank\" rel=\"noopener\">10916<\/a>\uff09<\/strong>\uff1a\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306b\u95a2\u3057\u3066\u306f\u512a\u308c\u305f\u5206\u96e2\u3092\u793a\u3057\u3001\u5206\u6790\u6642\u9593\u3082\u8a31\u5bb9\u7bc4\u56f2\u3067\u3057\u305f\u3002\u305f\u3060\u3057\u3001\u9162\u9178\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306b\u30d5\u30ed\u30f3\u30c6\u30a3\u30f3\u30b0\u304c\u898b\u3089\u308c\u3001\u4f4e\u6975\u6027\u56fa\u5b9a\u76f8\u306b\u3088\u308b\u6eb6\u89e3\u6027\u306e\u4f4e\u3055\u304c\u793a\u5506\u3055\u308c\u307e\u3057\u305f\uff08<strong>Figure 3<\/strong>\u53c2\u7167\uff09\u3002<\/li>\n<\/ul>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 3:<\/strong> Rtx-502.2\u30ab\u30e9\u30e0\u3067\u306e\u9162\u9178\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306f\u826f\u597d\u3068\u306f\u8a00\u3048\u305a\u3001\u56fa\u5b9a\u76f8\u3078\u306e\u6eb6\u89e3\u6027\u304c\u4f4e\u3044\u3053\u3068\u3092\u793a\u3057\u305f\uff08\u30d4\u30fc\u30af7\uff09\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1387.png\" alt=\"Custom Beverage Analysis Mix on Rtx-502.2\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1387<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>10916<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1387.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:150px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-4fc3f8e1 wp-block-group-is-layout-flex\">\n<ul class=\"wp-block-list has-theme-palette-2-color has-text-color has-link-color wp-elements-6\">\n<li class=\"has-theme-palette-5-color has-text-color has-link-color wp-elements-7\" style=\"margin-top:-30px;margin-bottom:-30px\"><strong>Rtx-1301\u3000\u30ab\u30e9\u30e0\u30d5\u30a9\u30fc\u30de\u30c3\u30c8\uff1a60 m \u00d7 0.25 mm ID \u00d7 1.00 \u00b5m\u3001\uff08cat.# <a href=\"https:\/\/restek.com\/p\/16056\" target=\"_blank\" rel=\"noopener\">16056<\/a>\uff09<\/strong>\uff1a\u6700\u3082\u30d0\u30e9\u30f3\u30b9\u306e\u826f\u3044\u7d50\u679c\u3092\u793a\u3057\u305f\u306e\u304cRtx-1301\u3067\u3001\u7279\u306b\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u306e\u5206\u96e2\u3068\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u512a\u308c\u3066\u3044\u307e\u3057\u305f\u3002\u7279\u7b46\u3059\u3079\u304d\u306f\u3001Rtx-VMS\u3067\u306f\u5171\u6eb6\u51fa\u3057\u3066\u3044\u305f2-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30683-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\u304c\u826f\u597d\u306b\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u70b9\u3067\u3059\u3002\u3055\u3089\u306b\u4f4e\u6975\u6027\u306eRtx-502.2\uff08\u30d5\u30a7\u30cb\u30eb\u30e1\u30c1\u30eb\u578b\u30dd\u30ea\u30b7\u30ed\u30ad\u30b5\u30f3\u76f8\uff09\u3068\u6bd4\u8f03\u3057\u3066\u3001\u6975\u6027\u306e\u9ad8\u3044\u30b7\u30a2\u30ce\u30d7\u30ed\u30d4\u30eb\u30d5\u30a7\u30cb\u30eb\u578b\u56fa\u5b9a\u76f8\u3092\u6301\u3064\u3053\u306e\u30ab\u30e9\u30e0\u3067\u306f\u3001\u9162\u9178\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3082\u5927\u5e45\u306b\u6539\u5584\u3055\u308c\u307e\u3057\u305f\uff08<strong>Figure 4<\/strong>\u53c2\u7167\uff09\u3002\u3053\u308c\u306f\u3001\u9162\u9178\u304cRtx-1301\u76f8\u3068\u89aa\u548c\u6027\u304c\u9ad8\u304f\u3001\u3088\u308a\u6eb6\u89e3\u3057\u3084\u3059\u3044\u305f\u3081\u3067\u3059\u3002\u3053\u306e\u3088\u3046\u306b\u3001Rtx-1301\u30ab\u30e9\u30e0\u306f20\u5206\u672a\u6e80\u306e\u5206\u6790\u6642\u9593\u3067\u3042\u308a\u306a\u304c\u3089\u3001\u5168\u4f53\u7684\u306b\u512a\u308c\u305f\u5206\u96e2\u3092\u793a\u3057\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306eGC\u5206\u6790\u306b\u304a\u3051\u308b\u63a8\u5968\u30ab\u30e9\u30e0\u3068\u8a00\u3048\u308b\u3067\u3057\u3087\u3046\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 4:<\/strong> Rtx-1301\u30ab\u30e9\u30e0\u306f\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u5168\u4f53\u3068\u3057\u3066\u6700\u3082\u512a\u308c\u305f\u5206\u96e2\u3092\u793a\u3057\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1388.png\" alt=\"Custom Beverage Analysis Mix on Rtx-1301\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1388<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16056<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1388.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3059\u308b\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u6210\u5206\u306b\u5bfe\u3059\u308bRtx-1301\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u3001\u5b9f\u969b\u306e\u30a2\u30eb\u30b3\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u3092\u7528\u3044\u3066\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u307e\u305aGC-FID\u3067\u30e1\u30bd\u30c3\u30c9\u3092\u69cb\u7bc9\u3057\u3001\u305d\u306e\u5f8cGC-MS\u306b\u79fb\u884c\u3057\u3066\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u307e\u3057\u305f\u3002\u30e1\u30bd\u30c3\u30c9\u79fb\u884c\u306b\u306fRestek\u306e<a href=\"https:\/\/ez.restek.com\/ezgc-mtfc\/ja\" data-type=\"link\" data-id=\"https:\/\/ez.restek.com\/ezgc-mtfc\/ja\" target=\"_blank\" rel=\"noopener\"><em>EZ<\/em>GC Method Translator<\/a>\u3092\u4f7f\u7528\u3057\u305f\u305f\u3081\u3001MS\u6761\u4ef6\u304c\u6570\u79d2\u3067\u4f5c\u6210\u3067\u304d\u307e\u3057\u305f\u3002\u6700\u7d42\u7684\u306a\u8abf\u6574\u306f\u3001\u30a4\u30bd\u30d6\u30bf\u30ce\u30fc\u30eb\u3068\u9162\u9178\u304c\u5341\u5206\u306b\u5206\u96e2\u3055\u308c\u308b\u3088\u3046\u3001\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u6700\u9069\u5316\u306e\u307f\u3067\u7d42\u4e86\u3057\u307e\u3057\u305f\u3002<strong>Figure 5<\/strong>\u3068<strong>Figure 6<\/strong>\u306b\u793a\u3059\u30e9\u30a4\u30a6\u30a4\u30b9\u30ad\u30fc\u306e\u5206\u6790\u3067\u306f\u3001GC-FID\u3068GC-MS\u306e\u3069\u3061\u3089\u306b\u304a\u3044\u3066\u3082\u3001\u30a4\u30bd\u30d6\u30bf\u30ce\u30fc\u30eb\u3068\u9162\u9178\u3001\u3055\u3089\u306b2-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\u30683-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\u306e\u826f\u597d\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u9162\u9178\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3082\u826f\u597d\u3067\u3042\u308a\u3001\u5206\u6790\u6642\u9593\u306f15 \u5206\u672a\u6e80\u3067\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 5:<\/strong> Rtx-1301\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3057\u305fGC-FID\u306b\u3088\u308b\u30e9\u30a4\u30a6\u30a4\u30b9\u30ad\u30fc\u306e\u5206\u6790\u3067\u306f\u3001\u512a\u308c\u305f\u5206\u96e2\u3001\u826f\u597d\u306a\u9162\u9178\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u300115\u5206\u672a\u6e80\u306e\u5206\u6790\u6642\u9593\u3067\u9054\u6210\u3055\u308c\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1395.png\" alt=\"Rye Whiskey on Rtx-1301\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1395<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16056<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1395.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 6:<\/strong> GC-MS\u306b\u3088\u308b\u30e9\u30a4\u30a6\u30a4\u30b9\u30ad\u30fc\u5206\u6790\u3067\u306f\u3001Figure 5\u306eGC-FID\u5206\u6790\u3068\u540c\u3058\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u304c\u5f97\u3089\u308c\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1396.png\" alt=\"Rye Whiskey on Rtx-1301\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1396<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16056<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1396.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">\u6dfb\u52a0\u7269\u306e\u5206\u6790<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u307e\u305f\u3001\u84b8\u7559\u9152\u306e\u5206\u6790\u3067\u306f\u3001\u672a\u8a18\u8f09\u306e\u6dfb\u52a0\u7269\u306b\u906d\u9047\u3059\u308b\u3053\u3068\u304c\u73cd\u3057\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u591a\u304f\u306e\u30b9\u30d4\u30ea\u30c3\u30c4\u3067\u306f\u3001\u30e9\u30d9\u30eb\u306b\u8868\u793a\u3055\u308c\u3066\u3044\u306a\u3044\u6210\u5206\u304c\u6700\u59272%\u7a0b\u5ea6\u542b\u307e\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u5b9f\u969b\u306b\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3084\u30b0\u30ea\u30bb\u30ea\u30f3\u306a\u3069\u304c\u6dfb\u52a0\u3055\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u30e9\u30e0\u9152\u3067\u306f\u719f\u6210\u54c1\u306b\u8fd1\u3044\u4e38\u307f\u306e\u3042\u308b\u53e3\u5f53\u305f\u308a\u3092\u5f97\u308b\u305f\u3081\u306b\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u304c\u7528\u3044\u3089\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u3001\u30b0\u30ea\u30bb\u30ea\u30f3\u306f\u307e\u308d\u3084\u304b\u3067\u6ed1\u3089\u304b\u306a\u98f2\u307f\u53e3\u3092\u4e0e\u3048\u308b\u76ee\u7684\u3067\u6dfb\u52a0\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<strong>Figure 7 <\/strong>\u301c <strong>Figure 11<\/strong>\u306b\u793a\u3055\u308c\u308b\u5b9f\u969b\u306e\u30a2\u30eb\u30b3\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790\u7d50\u679c\u3067\u3082\u3001\u3053\u3046\u3057\u305f\u5316\u5408\u7269\uff08\u6dfb\u52a0\u7269\uff09\u304c\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u3002Rtx-1301\u30ab\u30e9\u30e0\u306f\u3001\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u3067\u3042\u308b\u63ee\u767a\u6027\u6210\u5206\u306e\u5206\u96e2\u3001\u9162\u9178\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3001\u5206\u6790\u6642\u9593\u306e\u70b9\u3067\u512a\u308c\u305f\u7d50\u679c\u3092\u793a\u3057\u3066\u304a\u308a\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306eGC \u5206\u6790\u306b\u304a\u3044\u3066\u9ad8\u3044\u4fe1\u983c\u6027\u3068\u6c4e\u7528\u6027\u3092\u5099\u3048\u305f\u30ab\u30e9\u30e0\u3067\u3042\u308b\u3053\u3068\u304c\u6539\u3081\u3066\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 7:<\/strong> Rtx-1301\u30ab\u30e9\u30e0\u3068GC-FID\u3092\u7528\u3044\u305f\u30d6\u30e9\u30f3\u30c7\u30fc\u306e\u5206\u6790\u3067\u306f\u3001\u512a\u308c\u305f\u5206\u96e2\u304c\u5f97\u3089\u308c\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1391.png\" alt=\"Brandy on Rtx-1301\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1391<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16056<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1391.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 8:<\/strong> Rtx-1301\u30ab\u30e9\u30e0\u3068GC-FID\u3092\u7528\u3044\u305f\u30d6\u30e9\u30f3\u30c7\u30fc\u306e\u5206\u6790\u3067\u306f\u3001\u512a\u308c\u305f\u5206\u96e2\u304c\u5f97\u3089\u308c\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1392.png\" alt=\"Sherry on Rtx-1301\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1392<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16056<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1392.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 9:<\/strong> Rtx-1301\u30ab\u30e9\u30e0\u3068GC-FID\u3092\u7528\u3044\u305f\u30a2\u30a4\u30ea\u30c3\u30b7\u30e5\u30a6\u30a4\u30b9\u30ad\u30fc\u306e\u5206\u6790\u3067\u306f\u3001\u826f\u597d\u306a\u5206\u96e2\u306815\u5206\u672a\u6e80\u306e\u8fc5\u901f\u306a\u5206\u6790\u6642\u9593\u304c\u5f97\u3089\u308c\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1393.png\" alt=\"Irish Whiskey on Rtx-1301\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1393<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16056<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1393.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 10:<\/strong> Rtx-1301\u30ab\u30e9\u30e0\u3068GC-FID\u3092\u7528\u3044\u305f\u30de\u30eb\u30b5\u30e9\u306e\u5206\u6790\u3067\u306f\u3001\u826f\u597d\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1394.png\" alt=\"Marsala on Rtx-1301\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1394<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16056<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1394.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n<div class=\"wp-block-custom-chromatogram-article-top\"><div class=\"chromatogram-article-placeholder\"><div class=\"figure-heading\"><strong>Figure 11:<\/strong> Rtx-1301\u30ab\u30e9\u30e0\u3068GC-FID\u3092\u7528\u3044\u305f\u30e9\u30e0\u9152\u306e\u5206\u6790\u3067\u306f\u3001\u826f\u597d\u306a\u5206\u96e2\u3068\u6dfb\u52a0\u7269\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5f97\u3089\u308c\u305f\uff08\u30d4\u30fc\u30af\u30ea\u30b9\u30c8\u3068\u5206\u6790\u6761\u4ef6\u3092\u542b\u3080\u5b8c\u5168\u7248\u306fPDF\u3067\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u53ef\uff09\u3002<\/div><div class='chromatogram-article-inner-full'><div class=\"chromatogram-article-inner\">\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1390.png\" alt=\"Rum on Rtx-1301\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_FF1390<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>16056<\/li><li>23305<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_ff1390.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div>\n<\/div><\/div><\/div>\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u8457\u8005\u7d39\u4ecb<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/people-Hilliard-Corby.jpg\" alt=\"photo of corby\" width=\"350\" height=\"350\" title=\"-\"><\/td><td><strong>Corby Hilliard<\/strong><br>As an advanced scientist in Restek\u2019s GC lab with over 20 years of experience, Corby\u2019s focus is on generating methodology and application data predominately for the food, petrochemical, and environmental industries. He is also involved with R&amp;D and new product development.<\/td><\/tr><tr><td><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/people-King-Carolyn.jpg\" alt=\"photo of carolyn\" width=\"350\" height=\"350\" title=\"-\"><\/td><td><strong>Carolyn King<\/strong><br>Carolyn is currently a technical service specialist at Restek. She began her career in 2012 in the QC lab conducting testing to ensure product quality before joining the technical service group in 2015. Carolyn holds a BS in animal sciences and nutritional sciences from The Pennsylvania State University.<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">\u53c2\u7167\u6587\u732e<\/h2>\n\n\n\n<ol class=\"wp-block-list\">\n<li>AOAC International, AOAC Official methods of analysis, 22nd edition, Edited by George W. Latimer, Jr., 3 vols., Oxford University Press, Oxford, UK, 2023.<\/li>\n<\/ol>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/16056\">                                \u30ab\u30bf\u30ed\u30b0No. 16056                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rtx-1301 GC Capillary Column, 60 m, 0.25 mm ID, 1.00 \u00b5m\uff5cUSP G43 \u4e2d\u6975\u6027<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/16056\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">                                \u30ab\u30bf\u30ed\u30b0No. 23305                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23305\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22656\">                                \u30ab\u30bf\u30ed\u30b0No. 22656                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek ProFLOW 6000 \u6d41\u91cf\u8a08<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22656\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/19915\">                                \u30ab\u30bf\u30ed\u30b0No. 19915                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rtx-VMS GC Capillary Column, 30 m, 0.25 mm ID, 1.40 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/19915\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/10916\">                                \u30ab\u30bf\u30ed\u30b0No. 10916                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Rtx-502.2 GC Capillary Column, 60 m, 0.25 mm ID, 1.40 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/10916\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306e\u63ee\u767a\u6027\u6210\u5206\u3068GC\u5206\u6790\u306e\u91cd\u8981\u6027 \u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306b\u542b\u307e\u308c\u308b\u63ee\u767a\u6027\u6210\u5206\u306e\u30d7\u30ed\u30d5\u30a1\u30a4\u30eb\u306f\u3001\u9178\u985e\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u985e\u3001\u30a2\u30eb\u30c7\u30d2\u30c9\u985e\u3001\u305d\u3057\u3066\u5fae\u91cf\u306a\u304c\u3089\u9999\u308a\u3084\u5473\u308f\u3044\u306b\u5927\u304d\u304f\u5f71\u97ff\u3059\u308b\u305d\u306e\u4ed6\u306e\u30d5\u30ec\u30fc\u30d0\u30fc\u5316\u5408\u7269\u306a\u3069\u3001\u591a\u69d8\u306a\u6210\u5206\u304b\u3089\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u84b8\u7559\u9152\u3001\u30ef\u30a4\u30f3\u3001\u30d3\u30fc\u30eb\u306e\u5b98\u80fd\u8a55\u4fa1\u306b\u7cbe\u901a\u3057\u305f\u5c02\u9580\u5bb6\u306f\u3001\u540c\u3058\u88fd\u54c1\u304c\u4e8c\u3064\u3068\u3057\u3066\u5b58\u5728\u3057\u306a\u3044\u3068\u3088\u304f\u6307\u6458\u3057\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u305d\u308c\u305e\u308c\u306e\u98f2\u6599\u306b\u542b\u307e\u308c\u308b\u63ee\u767a\u6027\u6210\u5206\u306e\u308f\u305a\u304b\u306a\u5dee\u7570\u304c\u3001\u500b\u3005\u306e\u72ec\u81ea\u6027\u3092\u751f\u307f\u51fa\u3057\u3066\u3044\u308b\u305f\u3081\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u9055\u3044\u3092\u7406\u89e3\u3059\u308b\u306b\u306f\u3001\u5b98\u80fd\u8a55\u4fa1\u306b\u52a0\u3048\u3066\u3001\u6a5f\u5668\u5206\u6790\u306b\u3088\u308b\u5b9a\u6027\u7684\u30fb\u5b9a\u91cf\u7684\u8a55\u4fa1\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u54c1\u8cea\u4fdd\u8a3c\uff08QA\uff09\u306e\u62c5\u5f53\u8005\u306f\u3001\u4e21\u8005\u3092\u7d44\u307f\u5408\u308f\u305b\u308b\u3053\u3068\u3067\u3001\u88fd\u54c1\u306e\u7279\u6027\u306b\u3064\u3044\u3066\u3088\u308a\u5305\u62ec\u7684\u306a\u60c5\u5831\u3092\u5f97\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 \u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u306f\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u975e\u5e38\u306b\u5f37\u529b\u306a\u30c4\u30fc\u30eb\u3067\u3059\u304c\u3001\u540c\u6642\u306b\u6271\u3044\u3084\u3059\u3044\u5206\u6790\u624b\u6cd5\u3067\u3082\u3042\u308a\u307e\u3059\u3002\u7406\u7531\u306f\u4ee5\u4e0b\u306e\u901a\u308a\u3067\u3059\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001\u3053\u3046\u3057\u305fGC\u306e\u7279\u6027\u3092\u8e0f\u307e\u3048\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u4e2d\u306b\u542b\u307e\u308c\u308b\u63ee\u767a\u6027\u6210\u5206\u3092\u3069\u306e\u3088\u3046\u306b\u30e2\u30cb\u30bf\u30ea\u30f3\u30b0\u3067\u304d\u308b\u304b\u306b\u3064\u3044\u3066\u3001\u305d\u306e\u5206\u6790\u624b\u6cd5\u3068\u5fdc\u7528\u4f8b\u3092\u8a73\u3057\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002 \u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u4e2d\u306e\u30a2\u30eb\u30b3\u30fc\u30eb\u304a\u3088\u3073\u30a2\u30eb\u30c7\u30d2\u30c9\u306e\u5206\u6790 \u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306b\u306f\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u985e\u3084\u77ed\u9396\u30a2\u30eb\u30c7\u30d2\u30c9\u3092\u306f\u3058\u3081\u3068\u3059\u308b\u591a\u69d8\u306a\u63ee\u767a\u6027\u5316\u5408\u7269\u304c\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002GC\u306f\u3001\u3053\u308c\u3089\u306e\u5316\u5408\u7269\u3092\u3001\u30b5\u30f3\u30d7\u30eb\u62bd\u51fa\u3092\u884c\u308f\u305a\u306b\u76f4\u63a5\u5206\u6790\u3067\u304d\u308b\u70b9\u3067\u975e\u5e38\u306b\u6709\u52b9\u3067\u3059\u3002AOAC International\u3067\u3082\u3001\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\uff08\u30d5\u30fc\u30bc\u30eb\u6cb9\u3068\u3082\u547c\u3070\u308c\u308b\uff09\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3001\u3055\u3089\u306b\u306f\u9ad8\u6b21\u30a2\u30eb\u30b3\u30fc\u30eb\u306e\u5206\u6790\u6cd5\u304cGC\u3092\u7528\u3044\u305f\u624b\u6cd5\u3068\u3057\u3066\u516c\u8868\u3055\u308c\u3066\u3044\u307e\u3059\uff3b1\uff3d\u3002 \u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306f\u9ad8\u3044\u5206\u96e2\u52b9\u7387\u3092\u5099\u3048\u3066\u304a\u308a\u3001\u7279\u306b\u69cb\u9020\u304c\u985e\u4f3c\u3057\u305f\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u985e\u306e\u5206\u6790\u306b\u9069\u3057\u3066\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5e45\u5e83\u3044\u30a2\u30eb\u30b3\u30fc\u30eb\u306b\u3064\u3044\u3066\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u9069\u5207\u306a\u5206\u96e2\u3092\u5f97\u308b\u305f\u3081\u306b\u306f\u3001\u5206\u6790\u5bfe\u8c61\u306b\u5408\u3063\u305f\u9078\u629e\u6027\u3092\u3082\u3064\u56fa\u5b9a\u76f8\u3092\u9078\u3076\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u4e3b\u8981\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u3067\u3042\u308b 2-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\uff08\u30a4\u30bd\u30a2\u30df\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\uff09\u3068 3-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\uff08\u6d3b\u6027\u30a2\u30df\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\uff09\u306e\u5206\u96e2\u306f\u3001\u6b63\u78ba\u306a\u5206\u6790\u306e\u305f\u3081\u306b\u5fc5\u9808\u306e\u30dd\u30a4\u30f3\u30c8\u3067\u3059\u3002\u307e\u305f\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306f\u6c34\u3068\u30a8\u30bf\u30ce\u30fc\u30eb\u3092\u4e3b\u4f53\u3068\u3059\u308b\u305f\u3081\u3001\u6c34\u3001\u30a2\u30bb\u30c8\u30a2\u30eb\u30c7\u30d2\u30c9\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3068\u3044\u3063\u305f\u6210\u5206\u3092\u3057\u3063\u304b\u308a\u3068\u5206\u96e2\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u3089\u304c\u5171\u6eb6\u51fa\u3059\u308b\u3068\u3001\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c\u3084\u5fae\u91cf\u6210\u5206\u306e\u30d4\u30fc\u30af\u304c\u4e3b\u8981\u30d4\u30fc\u30af\u306b\u57cb\u3082\u308c\u308b\u3053\u3068\u3067\u3001\u6b63\u78ba\u306a\u5b9a\u91cf\u304c\u96e3\u3057\u304f\u306a\u308a\u307e\u3059\u3002\u52a0\u3048\u3066\u3001\u9162\u9178\u306f\u56fa\u5b9a\u76f8\u3068\u306e\u76f8\u6027\u306b\u3088\u3063\u3066\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u4e71\u308c\u3084\u3059\u304f\u3001\u5206\u6790\u4e0a\u306e\u6ce8\u610f\u70b9\u3068\u3057\u3066\u8003\u616e\u3059\u308b\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002 Tech Tip\uff08\u6280\u8853\u7684\u306a\u30d2\u30f3\u30c8\uff09\u30a8\u30bf\u30ce\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u3092\u6271\u3046\u969b\u306f\u3001\u30b7\u30ea\u30f3\u30b8\u306e\u5bff\u547d\u3092\u6700\u5927\u9650\u306b\u5ef6\u3070\u3059\u305f\u3081\u306b\u3001\u6c17\u5bc6\u6027\u306e\u9ad8\u3044\u30ac\u30b9\u30b7\u30ea\u30f3\u30b8\u3092\u4f7f\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002 \u9069\u5207\u306a\u9078\u629e\u6027\u3092\u6301\u3064GC\u30ab\u30e9\u30e0\u306e\u9078\u629e \u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306eGC\u5206\u6790\u306b\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3092\u9078\u5b9a\u3059\u308b\u305f\u3081\u3001\u6975\u6027\u306e\u7570\u306a\u308b3\u7a2e\u985e\u306e\u56fa\u5b9a\u76f8\u304c\u6bd4\u8f03\u8a55\u4fa1\u3055\u308c\u307e\u3057\u305f\u3002 \u8a55\u4fa1\u306b\u3042\u305f\u3063\u3066\u306f\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u826f\u5426\u3068\u4e3b\u8981\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306e\u5206\u96e2\u5ea6\u3092\u4e3b\u8981\u306a\u8a55\u4fa1\u6307\u6a19\u3068\u3057\u307e\u3057\u305f\u3002\u307e\u305a\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u5206\u6790\u3067\u4e00\u822c\u7684\u306b\u30c6\u30b9\u30c8\u3055\u308c\u308b\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3092\u542b\u3080\u6a19\u6e96\u8a66\u6599\u3092\u30a8\u30bf\u30ce\u30fc\u30eb\u4e2d 100 \u00b5g\/mL\u3067\u8abf\u88fd\u3057\u3001\u521d\u671f\u30b9\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u3092FID\u3067\u884c\u3044\u307e\u3057\u305f\u3002\u305d\u306e\u5f8c\u3001\u30d5\u30eb\u30b9\u30ad\u30e3\u30f3\u6cd5\uff0810\u2013400 m\/z\uff09\u3092\u7528\u3044\u3066MSD\u5206\u6790\u3092\u5b9f\u65bd\u3057\u3001\u6c34\u304c\u5341\u5206\u306b\u5206\u96e2\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3057\u305f\u3002 \u3044\u305a\u308c\u306e\u56fa\u5b9a\u76f8\u3082\u3001\u6c34\u3001\u30a2\u30bb\u30c8\u30a2\u30eb\u30c7\u30d2\u30c9\u3001\u30e1\u30bf\u30ce\u30fc\u30eb\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u306b\u3064\u3044\u3066\u306f\u826f\u597d\u306a\u5206\u96e2\u3092\u793a\u3057\u307e\u3057\u305f\u3002Figure 1\u306eRtx-1301\u30ab\u30e9\u30e0\u306b\u3088\u308b\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u306f\u3001\u3053\u308c\u3089\u5316\u5408\u7269\u306e\u5178\u578b\u7684\u306a\u5206\u96e2\u4f8b\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002 \u3054\u5b58\u77e5\u3067\u3057\u305f\u304b&nbsp;?\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u306f\u9ad8\u6b21\uff08\u3059\u306a\u308f\u3061\u4e8c\u7d1a\u307e\u305f\u306f\u4e09\u7d1a\uff09\u30a2\u30eb\u30b3\u30fc\u30eb\u3067\u3042\u308a\u3001\u30d3\u30fc\u30eb\u306b\u306f\u901a\u5e38\u5fae\u91cf\u542b\u307e\u308c\u3066\u3044\u307e\u3059\u3002\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u306f\u3001\u30a8\u30bf\u30ce\u30fc\u30eb\u3068\u985e\u4f3c\u306e\u751f\u6210\u7d4c\u8def\u3092\u7d4c\u3066\u751f\u6210\u3055\u308c\u3001\u8f9b\u5473\u3084\u30b9\u30d1\u30a4\u30b7\u30fc\u3055\u3001\u6eb6\u5a92\u81ed\u306e\u3088\u3046\u306a\u98a8\u5473\u3001\u3044\u308f\u3086\u308b\u30a2\u30eb\u30b3\u30fc\u30eb\u306e\u300c\u523a\u6fc0\u611f\u300d\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002\u30b9\u30c8\u30ed\u30f3\u30b0\u30a8\u30fc\u30eb\u3084\u30d0\u30fc\u30ec\u30a4\u30ef\u30a4\u30f3\u306a\u3069\u3001\u30b9\u30bf\u30a4\u30eb\u306b\u3088\u3063\u3066\u306f\u5c11\u91cf\u306a\u3089\u597d\u307e\u3057\u3044\u98a8\u5473\u3068\u306a\u308a\u307e\u3059\u304c\u3001\u30d4\u30eb\u30b9\u30ca\u30fc\u306a\u3069\u306e\u30e9\u30ac\u30fc\u3067\u306f\u4e0d\u5feb\u306a\u5473\u306b\u3064\u306a\u304c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u3055\u3089\u306b\u3001\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u306f\u9175\u6bcd\u306b\u3068\u3063\u3066\u306f\u6709\u5bb3\u3067\u3042\u308b\u305f\u3081\u3001\u30dc\u30c8\u30eb\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30f3\u306e\u30d3\u30fc\u30eb\u3067\u306f\u70ad\u9178\u4fdd\u6301\u6027\u3084\u6ce1\u306e\u4fdd\u6301\u529b\u306e\u4f4e\u4e0b\u3092\u62db\u304f\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u767a\u9175\u6e29\u5ea6\u304c\u9ad8\u3044\u3068\u3001\u9175\u6bcd\u306e\u6210\u9577\u304c\u904e\u5270\u306b\u65e9\u307e\u308a\u3001\u7a81\u7136\u5909\u7570\u304c\u8d77\u3053\u308a\u3084\u3059\u304f\u306a\u308b\u305f\u3081\u3001\u30d5\u30fc\u30bc\u30eb\u30a2\u30eb\u30b3\u30fc\u30eb\u306e\u751f\u6210\u304c\u4fc3\u9032\u3055\u308c\u307e\u3059\u3002 \u56fa\u5b9a\u76f8\u306e\u8a73\u7d30\u691c\u8a0e\u3067\u306f\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u7d50\u679c\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002 \u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790 \u30bf\u30fc\u30b2\u30c3\u30c8\u3068\u3059\u308b\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u6210\u5206\u306b\u5bfe\u3059\u308bRtx-1301\u30ab\u30e9\u30e0\u306e\u6027\u80fd\u3092\u78ba\u8a8d\u3059\u308b\u305f\u3081\u3001\u5b9f\u969b\u306e\u30a2\u30eb\u30b3\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u3092\u7528\u3044\u3066\u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002\u307e\u305aGC-FID\u3067\u30e1\u30bd\u30c3\u30c9\u3092\u69cb\u7bc9\u3057\u3001\u305d\u306e\u5f8cGC-MS\u306b\u79fb\u884c\u3057\u3066\u30c7\u30fc\u30bf\u3092\u53d6\u5f97\u3057\u307e\u3057\u305f\u3002\u30e1\u30bd\u30c3\u30c9\u79fb\u884c\u306b\u306fRestek\u306eEZGC Method Translator\u3092\u4f7f\u7528\u3057\u305f\u305f\u3081\u3001MS\u6761\u4ef6\u304c\u6570\u79d2\u3067\u4f5c\u6210\u3067\u304d\u307e\u3057\u305f\u3002\u6700\u7d42\u7684\u306a\u8abf\u6574\u306f\u3001\u30a4\u30bd\u30d6\u30bf\u30ce\u30fc\u30eb\u3068\u9162\u9178\u304c\u5341\u5206\u306b\u5206\u96e2\u3055\u308c\u308b\u3088\u3046\u3001\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u6700\u9069\u5316\u306e\u307f\u3067\u7d42\u4e86\u3057\u307e\u3057\u305f\u3002Figure 5\u3068Figure 6\u306b\u793a\u3059\u30e9\u30a4\u30a6\u30a4\u30b9\u30ad\u30fc\u306e\u5206\u6790\u3067\u306f\u3001GC-FID\u3068GC-MS\u306e\u3069\u3061\u3089\u306b\u304a\u3044\u3066\u3082\u3001\u30a4\u30bd\u30d6\u30bf\u30ce\u30fc\u30eb\u3068\u9162\u9178\u3001\u3055\u3089\u306b2-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\u30683-\u30e1\u30c1\u30eb-1-\u30d6\u30bf\u30ce\u30fc\u30eb\u306e\u826f\u597d\u306a\u5206\u96e2\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\u3002\u9162\u9178\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3082\u826f\u597d\u3067\u3042\u308a\u3001\u5206\u6790\u6642\u9593\u306f15 \u5206\u672a\u6e80\u3067\u3057\u305f\u3002 \u6dfb\u52a0\u7269\u306e\u5206\u6790 \u307e\u305f\u3001\u84b8\u7559\u9152\u306e\u5206\u6790\u3067\u306f\u3001\u672a\u8a18\u8f09\u306e\u6dfb\u52a0\u7269\u306b\u906d\u9047\u3059\u308b\u3053\u3068\u304c\u73cd\u3057\u304f\u3042\u308a\u307e\u305b\u3093\u3002\u591a\u304f\u306e\u30b9\u30d4\u30ea\u30c3\u30c4\u3067\u306f\u3001\u30e9\u30d9\u30eb\u306b\u8868\u793a\u3055\u308c\u3066\u3044\u306a\u3044\u6210\u5206\u304c\u6700\u59272%\u7a0b\u5ea6\u542b\u307e\u308c\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u3001\u5b9f\u969b\u306b\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3084\u30b0\u30ea\u30bb\u30ea\u30f3\u306a\u3069\u304c\u6dfb\u52a0\u3055\u308c\u308b\u5834\u5408\u304c\u3042\u308a\u307e\u3059\u3002\u4f8b\u3048\u3070\u3001\u30e9\u30e0\u9152\u3067\u306f\u719f\u6210\u54c1\u306b\u8fd1\u3044\u4e38\u307f\u306e\u3042\u308b\u53e3\u5f53\u305f\u308a\u3092\u5f97\u308b\u305f\u3081\u306b\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u304c\u7528\u3044\u3089\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u3001\u30b0\u30ea\u30bb\u30ea\u30f3\u306f\u307e\u308d\u3084\u304b\u3067\u6ed1\u3089\u304b\u306a\u98f2\u307f\u53e3\u3092\u4e0e\u3048\u308b\u76ee\u7684\u3067\u6dfb\u52a0\u3055\u308c\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002Figure 7 \u301c Figure 11\u306b\u793a\u3055\u308c\u308b\u5b9f\u969b\u306e\u30a2\u30eb\u30b3\u30fc\u30eb\u30b5\u30f3\u30d7\u30eb\u306e\u5206\u6790\u7d50\u679c\u3067\u3082\u3001\u3053\u3046\u3057\u305f\u5316\u5408\u7269\uff08\u6dfb\u52a0\u7269\uff09\u304c\u691c\u51fa\u3055\u308c\u307e\u3057\u305f\u3002Rtx-1301\u30ab\u30e9\u30e0\u306f\u3001\u30af\u30ea\u30c6\u30a3\u30ab\u30eb\u30da\u30a2\u3067\u3042\u308b\u63ee\u767a\u6027\u6210\u5206\u306e\u5206\u96e2\u3001\u9162\u9178\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3001\u5206\u6790\u6642\u9593\u306e\u70b9\u3067\u512a\u308c\u305f\u7d50\u679c\u3092\u793a\u3057\u3066\u304a\u308a\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u98f2\u6599\u306eGC \u5206\u6790\u306b\u304a\u3044\u3066\u9ad8\u3044\u4fe1\u983c\u6027\u3068\u6c4e\u7528\u6027\u3092\u5099\u3048\u305f\u30ab\u30e9\u30e0\u3067\u3042\u308b\u3053\u3068\u304c\u6539\u3081\u3066\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002 \u8457\u8005\u7d39\u4ecb Corby HilliardAs an advanced scientist in Restek\u2019s GC lab with over 20 years of experience, Corby\u2019s focus is on&#8230;<\/p>\n","protected":false},"author":11,"featured_media":6894,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[414],"class_list":["post-72510","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-FFAR4494-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"author_category":"1","first_name":"Restek","last_name":"Corporation","user_url":"https:\/\/www.linkedin.com\/company\/restek-corporation\/posts\/?feedView=all","job_title":"Chromatography Products and Solutions","description":"Restek is a leading provider of chromatography columns, accessories, and certified reference materials. Trust Restek for reliable, high-quality analytical solutions."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/72510","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=72510"}],"version-history":[{"count":42,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/72510\/revisions"}],"predecessor-version":[{"id":88048,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/72510\/revisions\/88048"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/6894"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=72510"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=72510"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=72510"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=72510"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=72510"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=72510"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=72510"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=72510"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=72510"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}