{"id":72741,"date":"2023-12-11T15:37:00","date_gmt":"2023-12-11T15:37:00","guid":{"rendered":"https:\/\/discover.restek.com\/?p=72741"},"modified":"2025-12-09T16:40:55","modified_gmt":"2025-12-09T16:40:55","slug":"restarting-your-gc-after-its-christmas-holiday-japan","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/gnbl5436-ja\/restarting-your-gc-after-its-christmas-holiday-japan","title":{"rendered":"\u3010GC\u518d\u7a3c\u50cd\u30c8\u30e9\u30d6\u30eb\u56de\u907f \u864e\u306e\u5dfb\u3011\u4f11\u6687\u660e\u3051GC\u3092\u30c8\u30e9\u30d6\u30eb\u306a\u304f\u52d5\u304b\u3059\u79d8\u8a23"},"content":{"rendered":"\n<p><strong>\u6700\u7d42\u66f4\u65b0\u65e5:2025\u5e7412\u67084\u65e5<\/strong><\/p>\n\n\n\n<p>\u5e74\u672b\u5e74\u59cb\u3084\u5927\u578b\u9023\u4f11\u306a\u3069\u3001\u7814\u7a76\u5ba4\u304c\u6570\u65e5\uff5e\u6570\u9031\u9593\u306b\u308f\u305f\u3063\u3066\u7121\u4eba\u306b\u306a\u308b\u671f\u9593\u3001GC\uff08\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff09\u88c5\u7f6e\u3092\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u3059\u308b\u3053\u3068\u306f\u3001\u96fb\u529b\u3084\u9ad8\u4fa1\u306a\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u7bc0\u7d04\u3059\u308b\u4e0a\u3067\u975e\u5e38\u306b\u6709\u52b9\u306a\u6226\u7565\u3067\u3059\u3002\u3057\u304b\u3057\u3001\u9069\u5207\u306a\u624b\u9806\u3092\u8e0f\u307e\u305a\u306b\u518d\u7a3c\u50cd\u3057\u3066\u3057\u307e\u3046\u3068\u3001\u601d\u308f\u306c\u30c8\u30e9\u30d6\u30eb\u306b\u76f4\u9762\u3057\u3001\u8cb4\u91cd\u306a\u7814\u7a76\u6642\u9593\u3092\u6d6a\u8cbb\u3057\u3066\u3057\u307e\u3046\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p>\u3053\u306e\u8a18\u4e8b\u3067\u306f\u3001\u4f11\u65e5\u671f\u9593\u4e2d\u306bGC\u5185\u3067\u4f55\u304c\u8d77\u3053\u3063\u3066\u3044\u308b\u306e\u304b\u3092\u89e3\u8aac\u3057\u3001<strong>\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c<\/strong>\u3001<strong>\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af<\/strong>\u3001<strong>\u30ab\u30e9\u30e0\u306e\u640d\u50b7<\/strong>\u3068\u3044\u3063\u305f\u554f\u984c\u3092\u9632\u3050\u305f\u3081\u306e\u5177\u4f53\u7684\u306a\u5bfe\u7b56\u3092\u3054\u7d39\u4ecb\u3057\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udd0d \u3010GC\u505c\u6b62\u4e2d\u306b\u8d77\u3053\u308b \u201c\u898b\u3048\u306a\u3044\u5909\u5316\u201d \u3011<\/h2>\n\n\n\n<p>GC\u88c5\u7f6e\u3092\u505c\u6b62\u3059\u308b\u3068\u3001\u5185\u90e8\u3067\u306f\u6b21\u306e2\u3064\u306e\u73fe\u8c61\u304c\u9032\u884c\u3057\u307e\u3059\u3002&nbsp;<br>\u9577\u671f\u4f11\u6687\u5f8c\u306eGC\u518d\u8d77\u52d5\u6642\u306b\u30c8\u30e9\u30d6\u30eb\u304c\u767a\u751f\u3057\u3084\u3059\u3044\u306e\u306f\u3001\u88c5\u7f6e\u505c\u6b62\u4e2d\u306b\u5185\u90e8\u3067\u6b21\u306e2\u3064\u306e\u73fe\u8c61\u304c\u9032\u884c\u3059\u308b\u305f\u3081\u3067\u3059\u3002\u3069\u3061\u3089\u3082\u3001\u4f11\u6687\u660e\u3051\u306e\u30c8\u30e9\u30d6\u30eb\u306e\u201c\u6839\u672c\u7684\u306a\u539f\u56e0\u201d\u306b\u306a\u308a\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u2460 \u30bb\u30d7\u30bf\u30e0\u30fb\u6ce8\u5165\u53e3\u7531\u6765\u306e\u6c5a\u67d3\u7269\u8cea\u306e\u84c4\u7a4d<\/h3>\n\n\n\n<p>\u30b7\u30ea\u30b3\u30f3\u88fd\u306e\u6ce8\u5165\u53e3\u7528\u30bb\u30d7\u30bf\u30e0\u306f\u3001WCOT\u30b7\u30ed\u30ad\u30b5\u30f3\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u3068\u540c\u3058\u6750\u8cea\u3067\u3059\u3002\u3053\u306e\u30bb\u30d7\u30bf\u30e0\u306f\u3001\u88c5\u7f6e\u505c\u6b62\u4e2d\u3082\u5fae\u91cf\u306e\u52a3\u5316\u751f\u6210\u7269\u3092\u653e\u51fa\u3057\u307e\u3059\u3002\u901a\u5e38\u904b\u8ee2\u6642\u306b\u306f\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3068\u5171\u306b\u30bb\u30d7\u30bf\u30e0\u30d1\u30fc\u30b8\u3068\u3057\u3066\u6392\u51fa\u3055\u308c\u307e\u3059\u304c\u3001\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u3084\u30b9\u30bf\u30f3\u30d0\u30a4\u4e2d\u3067\u30ab\u30e9\u30e0\u304c\u51b7\u5374\u3055\u308c\u3066\u3044\u308b\u3068\u3001\u3053\u306e\u5fae\u91cf\u306e\u52a3\u5316\u751f\u6210\u7269\u304c\u30ab\u30e9\u30e0\u5148\u7aef\u306b\u9759\u304b\u306b\u84c4\u7a4d\u3057\u3066\u3044\u304d\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p>\u3055\u3089\u306b\u3001\u6ce8\u5165\u53e3\u5185\u306b\u306f\u6ce8\u5165\u53e3\u58c1\u9762\u306e\u6c5a\u308c\u306e\u307b\u304b\u3001\u8a66\u6599\u6b8b\u6e23\u3084\u30bb\u30d7\u30bf\u30e0\u306e\u5fae\u7d30\u306a\u7834\u7247\u306a\u3069\u3082\u610f\u5916\u3068\u6b8b\u3063\u3066\u3044\u308b\u3053\u3068\u304c\u591a\u304f\u3001\u3053\u308c\u3089\u304c\u6642\u9593\u3068\u3068\u3082\u306b\u84b8\u767a\u3057\u3001\u51b7\u305f\u3044\u30ab\u30e9\u30e0\u306b\u3058\u308f\u3058\u308f\u5438\u7740\u3057\u307e\u3059\u3002\u4f11\u6687\u306e\u9577\u3055\u306b\u6bd4\u4f8b\u3057\u3066\u3053\u306e\u201c\u9759\u304b\u306a\u6c5a\u67d3\u201d\u306f\u9032\u884c\u3057\u3001\u518d\u8d77\u52d5\u5f8c\u306e\u6700\u521d\u306e\u6607\u6e29\u30d7\u30ed\u30b0\u30e9\u30e0\u3067\u4e00\u6c17\u306b\u6eb6\u51fa\u3001\u4e88\u671f\u305b\u306c\u30d4\u30fc\u30af\u3084\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c\u3068\u3057\u3066\u73fe\u308c\u308b\u306e\u3067\u3059\u3002&nbsp;<\/p>\n\n\n\n<p>\u3053\u3046\u3057\u305f\u6c5a\u67d3\u306f\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u4e2d\u306b\u30b9\u30d7\u30ea\u30c3\u30c8\u30d0\u30eb\u30d6\u3092\u9589\u3058\u3066\u3044\u308b\u3001\u3042\u308b\u3044\u306f\u30b9\u30d7\u30ea\u30c3\u30c8\u30d5\u30ed\u30fc\u3092\u5927\u304d\u304f\u7d5e\u3063\u3066\u3044\u308b\u3068\u60aa\u5316\u3059\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u30ac\u30b9\u7bc0\u7d04\u306b\u306f\u6709\u52b9\u3067\u3059\u304c\u3001\u9006\u306b\u30ab\u30e9\u30e0\u6c5a\u67d3\u3092\u5897\u3084\u3059\u7d50\u679c\u306b\u3082\u306a\u308b\u3053\u3068\u3082\u3002\u5bfe\u7b56\u3068\u3057\u3066\u306f\u300c\u30b9\u30d7\u30ea\u30c3\u30c8\u3092\u958b\u653e\u3057\u3001\u9ad8\u3081\u306e\u30b9\u30d7\u30ea\u30c3\u30c8\u30d5\u30ed\u30fc\u3092\u7dad\u6301\u3059\u308b\u300d\u65b9\u6cd5\u304c\u3042\u308a\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p>\u307e\u305f\u3001<strong>\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u30c8\u30e9\u30c3\u30d7\u5185\u306b\u5438\u7740\u3057\u3066\u3044\u308b\u6210\u5206\u304c\u505c\u6b62\u4e2d\u306b\u30b9\u30d7\u30ea\u30c3\u30c8\u30e9\u30a4\u30f3\u5074\u3078\u9006\u6d41\u3059\u308b<\/strong>\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p>\u3053\u308c\u304c\u30e9\u30a4\u30ca\u30fc\u3084\u30ab\u30e9\u30e0\u5165\u53e3\u306b\u623b\u308b\u3068\u3001\u6c5a\u67d3\u3084\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u306e\u539f\u56e0\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p>\uff08\u203b\u3053\u306e\u73fe\u8c61\u306f\u30d8\u30ea\u30a6\u30e0\u306b\u9650\u5b9a\u3055\u308c\u307e\u305b\u3093\u3002\u4e00\u822c\u7684\u306a\u30d0\u30c3\u30af\u30d5\u30ed\u30fc\u554f\u984c\u3068\u3057\u3066\u8d77\u3053\u308a\u5f97\u307e\u3059\u3002\uff09&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\u2461 \u30d8\u30ea\u30a6\u30e0\u62e1\u6563\u306b\u3088\u308b\u7a7a\u6c17\uff08\u9178\u7d20\u30fb\u6c34\u5206\uff09\u6df7\u5165&nbsp;<\/h3>\n\n\n\n<p>\u30d8\u30ea\u30a6\u30e0\u3092\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u3068\u3057\u3066\u4f7f\u7528\u3057\u3066\u3044\u308bGC\u3067\u306f\u3001\u505c\u6b62\u4e2d\u306b\u8208\u5473\u6df1\u3044\u73fe\u8c61\u304c\u8d77\u3053\u308a\u307e\u3059\u3002 \u30d8\u30ea\u30a6\u30e0\u306f\u975e\u5e38\u306b\u8efd\u304f\u62e1\u6563\u3057\u3084\u3059\u3044\u305f\u3081\u3001\u610f\u5916\u3068\u7c21\u5358\u306b\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u5916\u3078\u629c\u3051\u51fa\u3057\u3066\u3057\u307e\u3046\u306e\u3067\u3059\u3002&nbsp;<\/p>\n\n\n\n<p>\u305d\u306e\u7d50\u679c\u3001GC\u5185\u90e8\u306b\u306f<strong>\u3054\u304f\u5fae\u5f31\u306a\u201c\u9670\u5727\u201d <\/strong>\u304c\u767a\u751f\u3057\u3001\u5468\u56f2\u306e\u7a7a\u6c17\u304c\u9759\u304b\u306b\u88c5\u7f6e\u5185\u90e8\u3078\u5f15\u304d\u8fbc\u307e\u308c\u3066\u3044\u304d\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p>\u3053\u306e\u9006\u6d41\u3057\u305f\u7a7a\u6c17\u306b\u306f\u6c34\u5206\u304c\u591a\u304f\u542b\u307e\u308c\u3001\u51b7\u3048\u305f\u88c5\u7f6e\u5185\u90e8\u3067\u6c34\u5206\u306f\u7c21\u5358\u306b\u518d\u51dd\u7e2e\u3057\u3066\u3057\u307e\u3044\u307e\u3059\u3002 \u3053\u308c\u304c\u30ab\u30e9\u30e0\u3084\u6ce8\u5165\u53e3\u306a\u3069\u306b\u4ed8\u7740\u3057\u3001\u305d\u3053\u3092\u4ecb\u3057\u3066\u4e0d\u7d14\u7269\u304c\u6eb6\u3051\u8fbc\u307f\u3001\u4f11\u6687\u660e\u3051\u306e\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u3084\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u5b89\u5b9a\u6027\u4f4e\u4e0b\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u00a0<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83d\udeab \u3010\u4f11\u6687\u524d\u306e\u88c5\u7f6e\u6e96\u5099\u3067\u907f\u3051\u308b\u3079\u304d NG\u884c\u52d5\u307e\u3068\u3081\u3011&nbsp;<\/h2>\n\n\n\n<p>GC\u3092\u5b88\u308b\u305f\u3081\u306b\u907f\u3051\u308b\u3079\u304d\u884c\u52d5\u3092\u3001<strong>\u5b8c\u5168\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3<\/strong>\uff0f<strong>\u9577\u671f\u30b9\u30bf\u30f3\u30d0\u30a4<\/strong>\uff0f<strong>\u77ed\u671f\u30b9\u30bf\u30f3\u30d0\u30a4<\/strong>\u306e3\u3064\u306b\u5206\u3051\u3066\u6574\u7406\u3057\u307e\u3057\u305f\u3002&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\ud83d\udfe5 \u5b8c\u5168\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\uff08\u30ab\u30e9\u30e0\u3092\u5916\u3059\uff09\u306eNG\u884c\u52d5&nbsp;<\/h3>\n\n\n\n<p>\u274c \u30ab\u30e9\u30e0\u3092\u88c5\u7740\u3057\u305f\u307e\u307e\u5168\u505c\u6b62\u3057\u3066\u653e\u7f6e&nbsp;<\/p>\n\n\n\n<p>\u274c \u30ab\u30e9\u30e0\u7aef\u3092\u5bc6\u9589\u305b\u305a\u306b\u4fdd\u7ba1&nbsp;<\/p>\n\n\n\n<p>\u274c \u9ad8\u6e29\u72b6\u614b\u306e\u307e\u307e\u96fb\u6e90\u3092\u5207\u308b&nbsp;<\/p>\n\n\n\n<p>\u274c \u30ac\u30b9\u505c\u6b62\u5f8c\u3059\u3050\u306b\u30ab\u30e9\u30e0\u3092\u5916\u3059\uff08\u5ba4\u6e29\u307e\u3067\u51b7\u5374\u3057\u3066\u3044\u306a\u3044\uff09&nbsp;<\/p>\n\n\n\n<p>\u274c \u505c\u6b62\u524d\u306e\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u7701\u7565&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\ud83d\udfe9 \u9577\u671f\u30b9\u30bf\u30f3\u30d0\u30a4\uff08\u6570\u9031\u9593\uff09\u306eNG\u884c\u52d5&nbsp;<\/h3>\n\n\n\n<p>\u274c \u30aa\u30fc\u30d6\u30f3\u3092\u5b8c\u5168\u5ba4\u6e29\u306b\u3059\u308b\uff08\u9577\u671f\u505c\u6b62\u4e2d\u306e\u6c34\u5206\u84c4\u7a4d\u306b\u3088\u308a\u30c8\u30e9\u30d6\u30eb\u6df1\u523b\u5316\uff09&nbsp;<\/p>\n\n\n\n<p>\u274c \u30b9\u30d7\u30ea\u30c3\u30c8\u3092\u9589\u3058\u308b\uff0f\u6975\u7aef\u306b\u7d5e\u308b&nbsp;<\/p>\n\n\n\n<p>\u274c \u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u305b\u305a\u306b\u505c\u6b62&nbsp;<\/p>\n\n\n\n<p>\u274c \u6ce8\u5165\u53e3\u30fb\u691c\u51fa\u5668\u3092\u63a8\u5968\u30b9\u30bf\u30f3\u30d0\u30a4\u6e29\u5ea6\u7bc4\u56f2\u5916\u3067\u904b\u8ee2\u3059\u308b&nbsp;<\/p>\n\n\n\n<p>\u274c \u30ac\u30b9\u30c8\u30e9\u30c3\u30d7\u306a\u3057\u3067\u30ac\u30b9\u3092\u6d41\u3057\u3066\u9577\u671f\u30b9\u30bf\u30f3\u30d0\u30a4\u3059\u308b<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\ud83d\udfe6 \u77ed\u671f\u30b9\u30bf\u30f3\u30d0\u30a4\uff08\u9031\u672b\u301c\u6570\u65e5\uff09\u306eNG\u884c\u52d5&nbsp;<\/h3>\n\n\n\n<p>\u274c FID\u306e\u708e\u3092\u6d88\u3057\u3066\u653e\u7f6e&nbsp;<\/p>\n\n\n\n<p>\u274c \u30b9\u30d7\u30ea\u30c3\u30c8\u30d0\u30eb\u30d6\u3092\u5b8c\u5168\u306b\u9589\u3058\u308b&nbsp;<\/p>\n\n\n\n<p>\u274c \u30b9\u30d7\u30ea\u30c3\u30c8\u6d41\u91cf\u3092\u6975\u7aef\u306b\u4e0b\u3052\u308b\uff08\u7bc0\u30ac\u30b9\u3057\u3059\u304e\uff09&nbsp;<\/p>\n\n\n\n<p>\u274c \u30aa\u30fc\u30d6\u30f3\u3092\u5e38\u6e29\u307e\u3067\u4e0b\u3052\u308b\uff08\u6c34\u5206\u304c\u51dd\u7e2e\u3057\u3084\u3059\u3044\uff09&nbsp;<\/p>\n\n\n\n<p>\u274c \u6ce8\u5165\u53e3\u6e29\u5ea6\u3092\u4f4e\u304f\u3057\u3059\u304e\u308b\uff08\u52a3\u5316\u751f\u6210\u7269\u304c\u6b8b\u7559\uff09&nbsp;<\/p>\n\n\n\n<p>\u3053\u308c\u3089\u306eNG\u884c\u52d5\u3092\u907f\u3051\u308b\u3060\u3051\u3067\u3001<strong>\u4f11\u6687\u660e\u3051\u306eGC\u30c8\u30e9\u30d6\u30eb\u306f\u5927\u5e45\u306b\u6e1b\u5c11\u3057\u307e\u3059<\/strong>\u3002&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\u3010\u671f\u9593\u5225\u306e\u5bfe\u51e6\u65b9\u6cd5\u3011<\/h2>\n\n\n\n<p>\u4e0a\u8a18\u306eGC\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u4e2d\u306b\u767a\u751f\u3059\u308b\u554f\u984c\u3092\u9632\u304e\u3001\u30b9\u30e0\u30fc\u30ba\u306a\u518d\u7a3c\u50cd\u3092\u5b9f\u73fe\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u4f11\u6687\u671f\u9593\u306e\u9577\u3055\u306b\u5fdc\u3058\u305f\u9069\u5207\u306a\u5bfe\u51e6\u6cd5\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c\u91cd\u8981\u3067\u3059\u3002\u3053\u3053\u3067\u306f\u3001\u5177\u4f53\u7684\u306a\u5bfe\u7b56\u3092\u671f\u9593\u5225\u306b\u89e3\u8aac\u3057\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\ud83d\udfe5 \u5b8c\u5168\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\uff08\u30ab\u30e9\u30e0\u3092\u5916\u3059\uff09\u306e\u5834\u5408<\/h3>\n\n\n\n<p>\u9577\u671f\u306b\u308f\u305f\u308b\u4f11\u6b62\u3084\u3001\u88c5\u7f6e\u30e1\u30f3\u30c6\u30ca\u30f3\u30b9\u3092\u517c\u306d\u308b\u5834\u5408\u306b\u63a8\u5968\u3055\u308c\u308b\u65b9\u6cd5\u3067\u3059\u3002&nbsp;<\/p>\n\n\n\n<p><strong><em>\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u624b\u9806&nbsp;<\/em><\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u6ce8\u5165\u53e3\u3001GC\u30aa\u30fc\u30d6\u30f3\u3001\u691c\u51fa\u5668\u3092\u5b8c\u5168\u306b\u5ba4\u6e29\u307e\u3067\u51b7\u5374\u3057\u307e\u3059\u3002\u00a0<\/li>\n\n\n\n<li>\u5168\u3066\u306e\u30ac\u30b9\u306e\u4f9b\u7d66\u3092\u505c\u6b62\u3057\u307e\u3059\u3002\u00a0<\/li>\n\n\n\n<li><strong>\u30ab\u30e9\u30e0\u306e\u4fdd\u8b77\u304c\u6700\u91cd\u8981\u3067\u3059\u3002<\/strong>\u30ab\u30e9\u30e0\u3092\u614e\u91cd\u306b\u53d6\u308a\u5916\u3057\u3001\u4e21\u7aef\u3092\u30ab\u30e9\u30e0\u30ad\u30e3\u30c3\u30d7\uff08cat#22858, 21044\uff09\u3084\u30bb\u30d7\u30bf\u30e0\u7247\u3067\u78ba\u5b9f\u306b\u5bc6\u9589\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5916\u90e8\u304b\u3089\u306e\u6c5a\u67d3\u3084\u7a7a\u6c17\u30fb\u6c34\u5206\u306e\u4fb5\u5165\u3092\u9632\u304e\u307e\u3059\u3002\u5bc6\u9589\u3057\u305f\u30ab\u30e9\u30e0\u306f\u3001\u5c02\u7528\u306e\u7bb1\u3084\u30ad\u30e3\u30d3\u30cd\u30c3\u30c8\u3067\u5b89\u5168\u306b\u4fdd\u7ba1\u3057\u307e\u3057\u3087\u3046\u3002<\/li>\n<\/ol>\n\n\n\n<p><em><strong>\u518d\u7a3c\u50cd\u624b\u9806<\/strong><\/em><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>\u30e9\u30a4\u30ca\u30fc\u3068\u30bb\u30d7\u30bf\u30e0\u3092\u70b9\u691c\u3057\u3001\u5fc5\u8981\u3067\u3042\u308c\u3070\u65b0\u54c1\u306b\u4ea4\u63db\u3057\u307e\u3059\u3002\u3053\u308c\u3089\u306f\u6c5a\u67d3\u306e\u4e3b\u8981\u306a\u767a\u751f\u6e90\u3068\u306a\u308a\u5f97\u307e\u3059\u3002\u00a0<\/li>\n\n\n\n<li>\u53d6\u308a\u5916\u3057\u3066\u4fdd\u7ba1\u3057\u3066\u3044\u305f\u30ab\u30e9\u30e0\u3092\u518d\u88c5\u7740\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9\u3092\u3086\u3063\u304f\u308a\u3068\u4f9b\u7d66\u3057\u3001\u901a\u5e38\u6d41\u91cf\u306b\u623b\u3057\u306a\u304c\u3089\u3001<strong>\u5ba4\u6e29\u306730\u5206\u9593\u30b7\u30b9\u30c6\u30e0\u3092\u30d1\u30fc\u30b8<\/strong>\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30b7\u30b9\u30c6\u30e0\u5185\u306b\u6b8b\u5b58\u3059\u308b\u4e0d\u7d14\u7269\u3084\u7a7a\u6c17\u3092\u6392\u51fa\u3057\u307e\u3059\u3002\u00a0<\/li>\n\n\n\n<li>\u71c3\u713c\u30ac\u30b9\u306e\u6d41\u91cf\u3092\u8abf\u6574\u3057\u3001\u6ce8\u5165\u53e3\u3068\u691c\u51fa\u5668\u3092\u901a\u5e38\u6e29\u5ea6\u307e\u3067\u6607\u6e29\u3057\u307e\u3059\u3002FID\u3092\u4f7f\u7528\u3057\u3066\u3044\u308b\u5834\u5408\u306f\u3001\u708e\u304c\u70b9\u706b\u3057\u305f\u5f8c\u306b\u30e1\u30a4\u30af\u30a2\u30c3\u30d7\u30ac\u30b9\u3092\u30aa\u30f3\u306b\u3057\u307e\u3059\u3002FID\u306e\u6b63\u5e38\u306a\u70b9\u706b\u306f\u3001\u51b7\u305f\u3044\u30d3\u30fc\u30ab\u30fc\u3084\u6642\u8a08\u76bf\u3092\u8fd1\u3065\u3051\u3066\u6c34\u84b8\u6c17\u3067\u304f\u3082\u308b\u304b\u3069\u3046\u304b\u3067\u78ba\u8a8d\u3067\u304d\u307e\u3059\u3002\u00a0<\/li>\n\n\n\n<li>\u30ab\u30e9\u30e0\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\uff08\u30af\u30ea\u30fc\u30cb\u30f3\u30b0\u6607\u6e29\uff09\u3092\u5b9f\u884c\u3057\u307e\u3059\u3002\u4f8b\u3068\u3057\u3066\u300140\u00b0C\uff0810\u5206\u4fdd\u6301\uff09\u2192 10\u00b0C\/min \u3067\u30ab\u30e9\u30e0\u306eTmax\u307e\u3067\u6607\u6e29\u3057\u300130\u5206\u4fdd\u6301\u3059\u308b\u3053\u3068\u3067\u3001\u4f11\u65e5\u671f\u9593\u4e2d\u30ab\u30e9\u30e0\u306b\u84c4\u7a4d\u3057\u305f\u4e0d\u7d14\u7269\u3092\u53d6\u308a\u9664\u3051\u307e\u3059\u3002\u00a0<\/li>\n\n\n\n<li>\u6700\u5f8c\u306b\u3001\u7d14\u6eb6\u5a92\uff08\u5206\u6790\u306b\u9069\u3057\u305f\u3082\u306e\u3001\u307e\u305f\u306f\u30ab\u30e9\u30e0\u306e\u30c6\u30b9\u30c8\u30df\u30c3\u30af\u30b9\uff09\u3092\u6ce8\u5165\u3057\u3001\u3059\u3079\u3066\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u304c\u6b63\u5e38\u3067\u3042\u308b\u3053\u3068\u3092\u78ba\u8a8d\u3057\u307e\u3059\u3002<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\">\ud83d\udfe9 \u9577\u671f\u30b9\u30bf\u30f3\u30d0\u30a4\uff08\u6570\u9031\u9593\uff09\u306e\u5834\u5408<\/h3>\n\n\n\n<p>\u5b8c\u5168\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u3068\u77ed\u671f\u30b9\u30bf\u30f3\u30d0\u30a4\u306e\u4e2d\u9593\u7684\u306a\u5bfe\u7b56\u3067\u3059\u3002\u6d88\u8cbb\u96fb\u529b\u306f\u6291\u3048\u3064\u3064\u3001\u518d\u7a3c\u50cd\u6642\u306e\u554f\u984c\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th><strong>\u30d1\u30e9\u30e1\u30fc\u30bf<\/strong><\/th><th><strong>\u8a2d\u5b9a\u5024<\/strong><\/th><th><strong>\u5099\u8003<\/strong><\/th><\/tr><\/thead><tbody><tr><td>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9<\/td><td>0.5 \u2013 1 mL\/min<\/td><td>\u4f4e\u6d41\u91cf\u3092\u7dad\u6301\u3057\u3001\u30b7\u30b9\u30c6\u30e0\u3092\u4fdd\u8b77\u00a0<\/td><\/tr><tr><td>\u30b9\u30d7\u30ea\u30c3\u30c8\u6d41\u91cf<\/td><td>5 \u2013 10 mL\/min\u00a0<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\u30e9\u30a4\u30f3\u3078\u306e\u6c5a\u67d3\u3092\u9632\u3050<\/td><\/tr><tr><td>GC\u30aa\u30fc\u30d6\u30f3<\/td><td>40\u00b0C\u00a0<\/td><td>\u5b8c\u5168\u51b7\u5374\u305b\u305a\u3001\u6c34\u5206\u51dd\u7e2e\u30ea\u30b9\u30af\u3092\u4f4e\u6e1b<\/td><\/tr><tr><td>\u6ce8\u5165\u53e3<\/td><td>\u505c\u6b62<\/td><td>\u52a3\u5316\u7269\u8cea\u306e\u767a\u751f\u3092\u6291\u5236<\/td><\/tr><tr><td>\u691c\u51fa\u5668<\/td><td>\u505c\u6b62<\/td><td>\u691c\u51fa\u5668\u306e\u5bff\u547d\u3092\u4fdd\u8b77\u00a0<\/td><\/tr><tr><td>\u71c3\u713c\u30ac\u30b9\u30fb\u30e1\u30a4\u30af\u30a2\u30c3\u30d7\u30ac\u30b9<\/td><td>\u505c\u6b62<\/td><td>\u5b89\u5168\u3068\u30b3\u30b9\u30c8\u524a\u6e1b\u306e\u305f\u3081\u00a0<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u3053\u306e\u671f\u9593\u306e\u30b9\u30bf\u30f3\u30d0\u30a4\u3067\u306f\u3001\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u7528\u30c8\u30e9\u30c3\u30d7\u304c\u975e\u5e38\u306b\u6709\u52b9\u3067\u3059\u3002\u307e\u305f\u3001\u30b9\u30bf\u30f3\u30d0\u30a4\u524d\u306b\u306f\u5fc5\u305a\u30ea\u30fc\u30af\u30c1\u30a7\u30c3\u30af\u3092\u884c\u3044\u3001\u30b7\u30b9\u30c6\u30e0\u5185\u3078\u306e\u7a7a\u6c17\u6df7\u5165\u306e\u30ea\u30b9\u30af\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u91cd\u8981\u306a\u5b89\u5168\u7b56\u3068\u306a\u308a\u307e\u3059\u3002\u00a0<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">\ud83d\udfe6 \u77ed\u671f\u30b9\u30bf\u30f3\u30d0\u30a4\uff08\u9031\u672b\u301c\u6570\u65e5\uff09\u306e\u5834\u5408<\/h3>\n\n\n\n<p>\u6bd4\u8f03\u7684\u77ed\u671f\u9593\u306e\u4f11\u6b62\u3067\u3042\u308c\u3070\u3001\u88c5\u7f6e\u3092\u5b8c\u5168\u306b\u505c\u6b62\u305b\u305a\u3001\u4f4e\u96fb\u529b\u30e2\u30fc\u30c9\u3067\u30b9\u30bf\u30f3\u30d0\u30a4\u3055\u305b\u308b\u3053\u3068\u3067\u3001\u518d\u7a3c\u50cd\u6642\u306e\u624b\u9593\u3068\u6642\u9593\u3092\u5927\u5e45\u306b\u524a\u6e1b\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><thead><tr><th><strong>\u30d1\u30e9\u30e1\u30fc\u30bf<\/strong><\/th><th><strong>\u8a2d\u5b9a\u5024<\/strong><\/th><th><strong>\u5099\u8003<\/strong><\/th><\/tr><\/thead><tbody><tr><td>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9<\/td><td>0.5 \u2013 1 mL\/min<\/td><td>\u4f4e\u6d41\u91cf\u3067\u6c5a\u67d3\u7269\u8cea\u306e\u84c4\u7a4d\u3092\u6291\u5236\u00a0<\/td><\/tr><tr><td>\u30b9\u30d7\u30ea\u30c3\u30c8\u6d41\u91cf<\/td><td>5 \u2013 10 mL\/min\u00a0<\/td><td>\u30b9\u30d7\u30ea\u30c3\u30c8\u30d9\u30f3\u30c8\u304b\u3089\u306e\u7a7a\u6c17\u9006\u6d41\u9632\u6b62<\/td><\/tr><tr><td>GC\u30aa\u30fc\u30d6\u30f3<\/td><td>60 \u2013 70\u00b0C\u00a0\u00a0<\/td><td>\u30ab\u30e9\u30e0\u306e\u6c5a\u67d3\u30fb\u6c34\u5206\u51dd\u7e2e\u9632\u6b62\u306e\u305f\u3081\u306e\u6700\u4f4e\u6e29\u5ea6\u00a0<\/td><\/tr><tr><td>\u6ce8\u5165\u53e3<\/td><td>100\u00b0C\u00a0<\/td><td>\u4f4e\u6e29\u8a2d\u5b9a\u3067\u52a3\u5316\u7269\u8cea\u306e\u767a\u751f\u3092\u6291\u5236\u00a0<\/td><\/tr><tr><td>\u691c\u51fa\u5668<\/td><td>150\u00b0C\u00a0<\/td><td>\u4f4e\u6e29\u8a2d\u5b9a\u3067\u52a3\u5316\u3092\u6291\u5236\u3057\u3064\u3064\u3001\u518d\u8d77\u52d5\u3092\u5bb9\u6613\u306b\u00a0<\/td><\/tr><tr><td>FID\u306e\u708e<\/td><td><strong>\u6d88\u3055\u305a\u306b\u7dad\u6301<\/strong><\/td><td>\u518d\u70b9\u706b\u306e\u624b\u9593\u3092\u7701\u304d\u3001\u5b89\u5b9a\u7a3c\u50cd\u3092\u7dad\u6301\u00a0<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<p>\u3053\u306e\u65b9\u6cd5\u306f\u3001\u4f11\u6687\u660e\u3051\u306b\u8fc5\u901f\u306a\u5206\u6790\u518d\u958b\u304c\u6c42\u3081\u3089\u308c\u308b\u5834\u5408\u306b\u7279\u306b\u6709\u52b9\u3067\u3059\u3002&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">\ud83c\udfaf \u307e\u3068\u3081&nbsp;<\/h2>\n\n\n\n<p>GC\u88c5\u7f6e\u306e\u30b9\u30bf\u30f3\u30d0\u30a4\u3068\u518d\u7a3c\u50cd\u306b\u95a2\u3059\u308b\u6226\u7565\u306f\u3001\u4f11\u6687\u660e\u3051\u306b\u3069\u308c\u3060\u3051\u8fc5\u901f\u306b\u88c5\u7f6e\u3092\u7acb\u3061\u4e0a\u3052\u305f\u3044\u304b\u3001\u307e\u305f\u306f\u30e9\u30dc\u306e\u4e88\u7b97\u306b\u3088\u3063\u3066\u7570\u306a\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u3069\u306e\u65b9\u6cd5\u3092\u9078\u629e\u3059\u308b\u306b\u3057\u3066\u3082\u3001\u6700\u3082\u91cd\u8981\u306a\u306e\u306f\u300c<strong>\u8a08\u753b\u6027<\/strong>\u300d\u3067\u3059\u3002&nbsp;<\/p>\n\n\n\n<p>\u9069\u5207\u306a\u5bfe\u7b56\u3092\u8b1b\u3058\u308b\u3053\u3068\u3067\u3001\u6c5a\u67d3\u7269\u8cea\u306e\u84c4\u7a4d\u3001\u7a7a\u6c17\u3084\u6c34\u5206\u306e\u6df7\u5165\u3068\u3044\u3063\u305f\u554f\u984c\u3092\u9632\u304e\u3001<strong>\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c<\/strong>\u3084<strong>\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af<\/strong>\u3001<strong>\u30ab\u30e9\u30e0\u640d\u50b7<\/strong>\u306e\u30ea\u30b9\u30af\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002&nbsp;<\/p>\n\n\n\n<p>\u9577\u671f\u4f11\u6687\u306f\u30ea\u30d5\u30ec\u30c3\u30b7\u30e5\u306e\u671f\u9593\u3067\u3059\u304c\u3001\u88c5\u7f6e\u3082\u9069\u5207\u306b\u30b1\u30a2\u3059\u308b\u3053\u3068\u3067\u3001\u4f11\u6687\u660e\u3051\u306e\u7814\u7a76\u3092\u30b9\u30e0\u30fc\u30ba\u304b\u3064\u9ad8\u52b9\u7387\u3067\u30b9\u30bf\u30fc\u30c8\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u305c\u3072\u3053\u306e\u8a18\u4e8b\u3067\u7d39\u4ecb\u3057\u305f\u30dd\u30a4\u30f3\u30c8\u3092\u53c2\u8003\u306b\u3001\u7686\u3055\u3093\u306eGC\u88c5\u7f6e\u304c\u5e38\u306b\u6700\u9ad8\u306e\u30d1\u30d5\u30a9\u30fc\u30de\u30f3\u30b9\u3092\u767a\u63ee\u3067\u304d\u308b\u3088\u3046\u3001\u4e07\u5168\u306e\u6e96\u5099\u3092\u6574\u3048\u3066\u304f\u3060\u3055\u3044\u3002&nbsp;<\/p>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">Products Mentioned<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22181\">                                Catalog No. 22181                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Inlet Maintenance Kit, for Agilent GCs<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22181\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                Catalog No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22858\">                                Catalog No. 22858                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Silicone Capillary Column Caps, 10-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/22858\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21044\">                                Catalog No. 21044                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Universal Color-Coded Capillary Column Caps, glass, 10-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/21044\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>\u9577\u671f\u4f11\u6687\u660e\u3051\u306e\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u518d\u7a3c\u50cd\u3067\u8d77\u3053\u308a\u304c\u3061\u306a\u30d9\u30fc\u30b9\u30e9\u30a4\u30f3\u306e\u4e71\u308c\u3084\u30b4\u30fc\u30b9\u30c8\u30d4\u30fc\u30af\u3001\u30ab\u30e9\u30e0\u640d\u50b7\u306e\u30ea\u30b9\u30af\u3092\u56de\u907f\u3059\u308b\u79d8\u8a23\u3092\u89e3\u8aac\u3002\u77ed\u671f\u30fb\u9577\u671f\u30b9\u30bf\u30f3\u30d0\u30a4\u3084\u30b7\u30e3\u30c3\u30c8\u30c0\u30a6\u30f3\u624b\u9806\u306a\u3069\u3001\u30b9\u30e0\u30fc\u30ba\u306a\u518d\u7a3c\u50cd\u306e\u30dd\u30a4\u30f3\u30c8\u3092\u8a73\u3057\u304f\u7d39\u4ecb\u3057\u307e\u3059\u3002<\/p>\n","protected":false},"author":2,"featured_media":72684,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[2724],"class_list":["post-72741","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/blog-restarting-your-gc-after-its-christmas-holiday-01-1024x385.jpg",1024,385,true],"author_info":{"display_name":"Patrick Gallagher","author_link":"https:\/\/discover.restek.com\/ja\/author\/patrick-gallagherrestek-com\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":444,"filter":"raw","cat_ID":794,"category_count":444,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":2724,"user_id":0,"is_guest":1,"slug":"Petra M\u00fchlbach","display_name":"Petra M\u00fchlbach","avatar_url":"https:\/\/secure.gravatar.com\/avatar\/?s=96&d=mm&r=g","0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/72741","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=72741"}],"version-history":[{"count":2,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/72741\/revisions"}],"predecessor-version":[{"id":72758,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/72741\/revisions\/72758"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/72684"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=72741"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=72741"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=72741"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=72741"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=72741"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=72741"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=72741"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=72741"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=72741"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}