{"id":74586,"date":"2026-01-19T19:41:14","date_gmt":"2026-01-19T19:41:14","guid":{"rendered":"https:\/\/discover.restek.com\/?p=74586"},"modified":"2026-10-02T14:37:31","modified_gmt":"2026-10-02T14:37:31","slug":"achieving-lower-detection-limits-for-semivolatiles-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/application-notes-ja\/evan5255-ja\/achieving-lower-detection-limits-for-semivolatiles-ja","title":{"rendered":"\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff5c\u5fae\u91cf\u5206\u6790\u30fb\u611f\u5ea6\u6539\u5584"},"content":{"rendered":"\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:1.5rem\"><strong>\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306eGC-MS\u5fae\u91cf\u5206\u6790\u306b\u304a\u3051\u308b\u691c\u51fa\u9650\u754c\u30fb\u5b9a\u91cf\u4e0b\u9650\u6539\u5584\u306e\u30dd\u30a4\u30f3\u30c8<\/strong><\/p>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:1.8rem\"><strong>Key Highlights<\/strong><\/h2>\n\n\n<style>.wp-block-kadence-iconlist.kt-svg-icon-list-items74586_a94cc8-11:not(.this-stops-third-party-issues){margin-top:0px;margin-bottom:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items74586_a94cc8-11 ul.kt-svg-icon-list:not(.this-prevents-issues):not(.this-stops-third-party-issues):not(.tijsloc){margin-top:0px;margin-right:0px;margin-bottom:var(--global-kb-spacing-sm, 1.5rem);margin-left:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items74586_a94cc8-11 ul.kt-svg-icon-list{grid-row-gap:5px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items74586_a94cc8-11 ul.kt-svg-icon-list .kt-svg-icon-list-item-wrap .kt-svg-icon-list-single{margin-right:10px;}.kt-svg-icon-list-items74586_a94cc8-11 ul.kt-svg-icon-list .kt-svg-icon-list-item-wrap, .kt-svg-icon-list-items74586_a94cc8-11 ul.kt-svg-icon-list .kt-svg-icon-list-item-wrap a{font-size:1.2rem;}.kt-svg-icon-list-items74586_a94cc8-11 ul.kt-svg-icon-list .kt-svg-icon-list-level-0 .kt-svg-icon-list-single svg{font-size:20px;}<\/style>\n<div class=\"wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items74586_a94cc8-11 kt-svg-icon-list-columns-1 alignleft\"><ul class=\"kt-svg-icon-list\"><style>.kt-svg-icon-list-item-74586_334f52-c0 .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-74586_334f52-c0\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_checkCircle kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M22 11.08V12a10 10 0 1 1-5.93-9.14\"\/><polyline points=\"22 4 12 14.01 9 11.01\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\">TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u304c\u3001\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u3092\u542b\u3080\u5e45\u5e83\u3044\u5316\u5408\u7269\u3068\u30ab\u30e9\u30e0\u8868\u9762\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u3092\u5927\u5e45\u306b\u6291\u5236<br><\/span><\/li>\n\n\n<style>.kt-svg-icon-list-item-74586_5fcb22-91 .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-74586_5fcb22-91\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_checkCircle kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M22 11.08V12a10 10 0 1 1-5.93-9.14\"\/><polyline points=\"22 4 12 14.01 9 11.01\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\">\u6975\u3081\u3066\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u306b\u3088\u308a\u3001\u5206\u6790\u306e\u96e3\u3057\u3044\u591a\u69d8\u306a\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u306e\u5b9a\u91cf\u4e0b\u9650\u30fb\u691c\u51fa\u9650\u754c\u3092\u6539\u5584<br><\/span><\/li>\n\n\n<style>.kt-svg-icon-list-item-74586_7999a1-a0 .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-74586_7999a1-a0\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_checkCircle kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M22 11.08V12a10 10 0 1 1-5.93-9.14\"\/><polyline points=\"22 4 12 14.01 9 11.01\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\">RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u3068\u306e\u6bd4\u8f03\u8a66\u9a13\u306b\u304a\u3044\u3066\u300152\u5316\u5408\u7269\u4e2d\u3001 MDL\u3067\u306f60%\u3001LLOQ\u3067\u306f63%\u306e\u5316\u5408\u7269\u3067\u512a\u308c\u305f\u6027\u80fd\u3092\u9054\u6210<\/span><\/li>\n<\/ul><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">Abstract\uff5c\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u691c\u51fa\u9650\u754c\u3068TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306e\u5f71\u97ff<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u672c\u7814\u7a76\u3067\u306f\u3001GC \u30ab\u30e9\u30e0\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u304c GC-MS\/MS \u306b\u3088\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306e\u691c\u51fa\u9650\u754c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u304b\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002RMX-5Sil MS\u30ab\u30e9\u30e0\u3068\u7af6\u5408\u3059\u308b\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u3092\u6bd4\u8f03\u3057\u305f\u3068\u3053\u308d\u3001RMX-5Sil MS \u30ab\u30e9\u30e0\u306f\u8a55\u4fa1\u3057\u305f\u5316\u5408\u7269\u306e\u304a\u3088\u305d 3 \u5206\u306e 2 \u3067\u3001\u3088\u308a\u512a\u308c\u305f MDL\u304a\u3088\u3073 LLOQ\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u8868\u9762\u306e\u6d3b\u6027\u90e8\u4f4d\u304c\u52b9\u679c\u7684\u306b\u6291\u5236\u3055\u308c\u3001\u5e83\u7bc4\u306a\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u3067\u9ad8\u3044\u5fdc\u7b54\u3068\u5b89\u5b9a\u3057\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5f97\u3089\u308c\u305f\u305f\u3081\u3067\u3059\u3002\u672c\u8a66\u9a13\u3067\u306f\u6eb6\u5a92\u30d9\u30fc\u30b9\u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u7528\u3044\u3066\u304a\u308a\u3001\u524d\u51e6\u7406\u3084\u62bd\u51fa\u306e\u5f71\u97ff\u3092\u6392\u9664\u3057\u305f\u3046\u3048\u3067\u30ab\u30e9\u30e0\u672c\u6765\u306e\u6027\u80fd\u5dee\u3092\u660e\u78ba\u306b\u8a55\u4fa1\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">Introduction\uff5cSVOC\u306eGC-MS\/MS\u5206\u6790\u3068\u691c\u51fa\u611f\u5ea6\uff08MDL\u30fbLLOQ\uff09<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u74b0\u5883\u4e2d\u306b\u5fae\u91cf\u3067\u5b58\u5728\u3059\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u306e\u6b63\u78ba\u306a\u5b9a\u91cf\u306f\u3001\u6c5a\u67d3\u306e\u628a\u63e1\u3084\u898f\u5236\u9075\u5b88\u3001\u3055\u3089\u306b\u306f\u4eba\u3068\u751f\u614b\u7cfb\u306e\u30ea\u30b9\u30af\u8a55\u4fa1\u306b\u304a\u3044\u3066\u91cd\u8981\u3067\u3059\u3002GC-MS\/MS \u306f\u9ad8\u3044\u9078\u629e\u6027\u3068\u611f\u5ea6\u3092\u5099\u3048\u3066\u304a\u308a\u3001SVOC \u5206\u6790\u306e\u30e1\u30bd\u30c3\u30c9\u691c\u51fa\u9650\u754c\uff08MDL\uff09\u304a\u3088\u3073\u5b9a\u91cf\u4e0b\u9650\uff08LLOQ\uff09\u3092\u6539\u5584\u3059\u308b\u305f\u3081\u306e\u4e3b\u8981\u306a\u5206\u6790\u6280\u8853\u3068\u3057\u3066\u5e83\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u9ad8\u611f\u5ea6\u306a\u30e1\u30bd\u30c3\u30c9\u306b\u3088\u308a\u3001\u8a66\u9a13\u5ba4\u306f\u62bd\u51fa\u91cf\u3092\u5c11\u306a\u304f\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u3092\u63a1\u7528\u3057\u3001\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3\u306a\u3069\u5869\u7d20\u7cfb\u6eb6\u5a92\u306e\u4f7f\u7528\u91cf\u524a\u6e1b\u3092\u56f3\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u62bd\u51fa\u91cf\u3092\u6e1b\u3089\u3059\u4f4e\u5bb9\u91cf\u62bd\u51fa\u6cd5\u306f\u3001\u64cd\u4f5c\u304c\u7c21\u4fbf\u3067\u6eb6\u5a92\u4f7f\u7528\u91cf\u3092\u6291\u3048\u3089\u308c\u308b\u4e00\u65b9\u3001\u51e6\u7406\u3059\u308b\u8a66\u6599\u91cf\u304c\u5c11\u306a\u3044\u305f\u3081\u3001\u62bd\u51fa\u6db2\u306b\u542b\u307e\u308c\u308b\u5206\u6790\u5bfe\u8c61\u7269\u8cea\u306e\u7dcf\u91cf\u304c\u5f93\u6765\u6cd5\u3088\u308a\u5c11\u306a\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u62bd\u51fa\u6db2\u4e2d\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6fc3\u5ea6\u306f\u4f4e\u304f\u306a\u308a\u3001\u5206\u6790\u5074\u306b\u306f\u3088\u308a\u9ad8\u3044\u611f\u5ea6\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u80cc\u666f\u304b\u3089\u3001GC-MS\/MS \u306b\u3088\u308b\u9ad8\u611f\u5ea6\u691c\u51fa\u306e\u9700\u8981\u304c\u9ad8\u307e\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306f\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u306a\u3069\u591a\u69d8\u306a\u5316\u5b66\u7279\u6027\u3092\u6301\u3061\u3001\u305d\u306e\u4e00\u90e8\u306f\u5206\u6790\u4e2d\u306b\u30ab\u30e9\u30e0\u8868\u9762\u306e\u6d3b\u6027\u90e8\u4f4d\uff08\u4f8b\uff1a\u30b7\u30e9\u30ce\u30fc\u30eb\uff09\u3068\u76f8\u4e92\u4f5c\u7528\u3057\u3001\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u3084\u5fdc\u7b54\u4f4e\u4e0b\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u3053\u3046\u3057\u305f\u8ab2\u984c\u3092\u514b\u670d\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6d41\u8def\uff08sample flow path\uff09\u5168\u4f53\u3067\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u304c\u78ba\u4fdd\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002GC \u30ab\u30e9\u30e0\u30e1\u30fc\u30ab\u30fc\u5404\u793e\u306f\u3001\u30ab\u30e9\u30e0\u8868\u9762\u3092\u4e2d\u6027\u5316\u3057\u3066\u30d4\u30fc\u30af\u5f62\u72b6\u60aa\u5316\u3084\u611f\u5ea6\u4f4e\u4e0b\u306e\u539f\u56e0\u3068\u306a\u308b\u76f8\u4e92\u4f5c\u7528\u3092\u6291\u5236\u3059\u308b\u305f\u3081\u3001\u3055\u307e\u3056\u307e\u306a\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u5f93\u6765\u306e\u51e6\u7406\u3067\u306f\u7279\u5b9a\u306e\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u306e\u307f\u5341\u5206\u306a\u52b9\u679c\u304c\u5f97\u3089\u308c\u305f\u3068\u3057\u3066\u3082\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u4e07\u904d\u306a\u304f\u52b9\u679c\u3092\u5f97\u308b\u3053\u3068\u306f\u6975\u3081\u3066\u96e3\u3057\u3044\u8ab2\u984c\u3068\u3057\u3066\u6b8b\u3063\u3066\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">Restek\u306fRMX \u30ab\u30e9\u30e0\u30b7\u30ea\u30fc\u30ba\u306b\u6b21\u4e16\u4ee3TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3092\u63a1\u7528\u3057\u3001\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u306e\u3044\u305a\u308c\u306e\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3082\u5e83\u304f\u6709\u52b9\u306a\u4e0d\u6d3b\u6027\u8868\u9762\u3092\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002\u672c\u7814\u7a76\u3067\u306f\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u3068\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066\u3001MDL \u304a\u3088\u3073 LLOQ \u3092\u8a55\u4fa1\u3057\u3001\u9054\u6210\u3067\u304d\u308b\u691c\u51fa\u9650\u754c\u304a\u3088\u3073\u5b9a\u91cf\u4e0b\u9650\u306e\u5dee\u3092\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u30b5\u30f3\u30d7\u30eb\u30de\u30c8\u30ea\u30af\u30b9\u306e\u5f71\u97ff\u3092\u6392\u9664\u3057\u3066\u30ab\u30e9\u30e0\u6027\u80fd\u305d\u306e\u3082\u306e\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u3001\u5b9f\u9a13\u306b\u306f\u6eb6\u5a92\u30d9\u30fc\u30b9\u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u7528\u3044\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image74586_54d98e-f8:not(.kb-image-is-ratio-size) .kb-img, .kb-image74586_54d98e-f8.kb-image-is-ratio-size{padding-right:100px;padding-left:100px;}.kb-image74586_54d98e-f8 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image74586_54d98e-f8\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-technical-service-JP\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"170\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-1024x170.png\" alt=\"\u304a\u554f\u3044\u5408\u308f\u305b\uff5cRestek\" class=\"kb-img wp-image-82127\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-1024x170.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-300x50.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-768x127.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">Experimental\uff5cRMX-5Sil MS \u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f GC-MS\/MS \u5206\u6790\u6761\u4ef6<\/h2>\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size: 1.1rem; font-weight: bold; color: #555; margin-bottom: -0.5rem;\">Standard and Sample Preparation\uff5c \u6a19\u6e96\u6eb6\u6db2\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd<\/h3>\n\n\n<p class=\"wp-block-paragraph\">\u691c\u91cf\u7dda\u6a19\u6e96\u6eb6\u6db2\u306f\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3\u3067 0.5\u30011\u30012\u30015\u300110\u300120\u300150\u3001100\u3001200\u3001500\u30011000\u30012000\u30015000 ppb \u306e\u6fc3\u5ea6\u3067\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002\u4e21\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066 Day1 \u306b\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3057\u30010.5\u301c100 ppb \u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u5404\u6fc3\u5ea6 3 \u56de\u305a\u3064\u6ce8\u5165\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5404\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306b\u304a\u3051\u308b\u76f4\u7dda\u7684\u306a\u691c\u91cf\u7bc4\u56f2\u3092\u5fdc\u7b54\u304b\u3089\u6c7a\u5b9a\u3057\u307e\u3057\u305f\u3002Day2 \u304a\u3088\u3073 Day3 \u306b\u306f\u3001\u65b0\u305f\u306b 0.5\u301c100 ppb \u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u8abf\u88fd\u3057\u3001\u540c\u69d8\u306b\u5404\u6fc3\u5ea6 3 \u56de\u306e\u6ce8\u5165\u3092\u884c\u3044\u3001\u5404\u30ab\u30e9\u30e0\u30fb\u5404\u5316\u5408\u7269\u306e MDL \u304a\u3088\u3073 LLOQ \u306e\u7b97\u51fa\u306b\u7528\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size: 1.1rem; font-weight: bold; color: #555; margin-bottom: -0.5rem;\">Instrument Conditions\uff5cGC-MS\/MS \u6e2c\u5b9a\u6761\u4ef6<\/h3>\n\n\n<p class=\"wp-block-paragraph\">\u5206\u6790\u306f\u3001RMX-5Sil MS \u30ab\u30e9\u30e0\u304a\u3088\u3073\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\uff08\u3044\u305a\u308c\u3082\u30ab\u30e9\u30e0\u30b5\u30a4\u30ba\u306f 30 m \u00d7 0.25 mm ID \u00d7 0.25 \u03bcm\uff09\u3092\u7528\u3044\u3066\u5b9f\u65bd\u3057\u307e\u3057\u305f\u3002\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u6e2c\u5b9a\u306b\u306f Thermo TRACE 1310 GC \u3068 TSQ 8000 \u8cea\u91cf\u5206\u6790\u8a08\u3092\u7528\u3044\u3001\u4e0b\u8a18\u6761\u4ef6\u3067 GC-MS\/MS \u5206\u6790\u3092\u884c\u3044\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u6ce8\u5165\u91cf : 1 \u00b5L<\/li>\n\n\n\n<li>Liner: Topaz 4 mm Precision inlet liner \u30a6\u30fc\u30eb\u5165\u308a (cat.# <a href=\"https:\/\/www.restek.com\/global\/ja\/p\/23267\" target=\"_blank\" rel=\"noopener\">23267<\/a>)<\/li>\n\n\n\n<li>\u6ce8\u5165\u53e3 : 280 \u00b0C; 10:1 split; 1.2 mL\/min<\/li>\n\n\n\n<li>\u30ad\u30e3\u30ea\u30e4\u30fc\u30ac\u30b9 : \u30d8\u30ea\u30a6\u30e0<\/li>\n\n\n\n<li>\u30aa\u30fc\u30d6\u30f3 : 40 \u00b0C (1 min) \u2013  280 \u00b0C (12 \u00b0C\/min) \u2013 310 \u00b0C (3 \u00b0C\/min)<\/li>\n\n\n\n<li>\u691c\u51fa\u5668 : MS\/MS\uff08SRM \u30e2\u30fc\u30c9\uff09\u3001\u30c8\u30e9\u30f3\u30b9\u30d5\u30a1\u30fc\u30e9\u30a4\u30f3 280 \u00b0C\u3001\u30a4\u30aa\u30f3\u6e90 330 \u00b0C\uff08SRM \u30c8\u30e9\u30f3\u30b8\u30b7\u30e7\u30f3\u306f\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3092\u53c2\u7167\uff09<\/li>\n<\/ul>\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size: 1.1rem; font-weight: bold; color: #555; margin-bottom: -0.5rem;\">Data Analysis\uff5c\u691c\u51fa\u9650\u754c\u304a\u3088\u3073\u5b9a\u91cf\u4e0b\u9650\u306e\u7b97\u51fa\u65b9\u6cd5<\/h3>\n\n\n<p class=\"wp-block-paragraph\">MDL \u306f\u3001\u5404\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u3001\u6700\u3082\u4f4e\u3044\u691c\u91cf\u6fc3\u5ea6\u306b\u304a\u3051\u308b\u300c\u518d\u8a08\u7b97\u3055\u308c\u305f\u6fc3\u5ea6\u5024\uff08back-calculated concentration\uff09\u300d\u306e\u6a19\u6e96\u504f\u5dee\u306b\u3001\u81ea\u7531\u5ea6 8 \u306b\u5bfe\u5fdc\u3059\u308b t \u5024\uff08t = 2.896\u3001n = 9\uff09\u3092\u4e57\u3058\u3066\u7b97\u51fa\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001\u691c\u91cf\u7dda\u4e0b\u9650\u6fc3\u5ea6\u4ed8\u8fd1\u3067\u306e\u6e2c\u5b9a\u3070\u3089\u3064\u304d\u3092\u7d71\u8a08\u7684\u306b\u8a55\u4fa1\u3059\u308b\u6a19\u6e96\u7684\u624b\u6cd5\u3067\u3059\u3002LLOQ \u306f\u540c\u3058\u30c7\u30fc\u30bf\u30bb\u30c3\u30c8\u304b\u3089\u6c42\u3081\u3001\u5404\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306b\u3064\u3044\u3066\u56de\u53ce\u7387\u304c 80\u301c120%\uff08\u307e\u305f\u306f\u305d\u308c\u306b\u6700\u3082\u8fd1\u3044\u5024\uff09\u3068\u306a\u308b\u3001\u6700\u3082\u4f4e\u3044\u691c\u91cf\u70b9\u3068\u3057\u3066\u5b9a\u7fa9\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image74586_d706ed-44.kb-image-is-ratio-size, .kb-image74586_d706ed-44 .kb-image-is-ratio-size{max-width:700px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image74586_d706ed-44.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image74586_d706ed-44 .kb-image-is-ratio-size{align-self:unset;}.kb-image74586_d706ed-44 figure{max-width:700px;}.kb-image74586_d706ed-44 .image-is-svg, .kb-image74586_d706ed-44 .image-is-svg img{width:100%;}.kb-image74586_d706ed-44 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image74586_d706ed-44\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3445-ja\/ezgc-online-tools-japan\" class=\"kb-advanced-image-link\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"238\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-1024x238.png\" alt=\"GC\u5206\u6790\u6761\u4ef6, \u30e1\u30bd\u30c3\u30c9\u958b\u767a, \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\uff5cRestek\" class=\"kb-img wp-image-81949\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-1024x238.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-300x70.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-768x179.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\">Results and Discussion\uff5cRMX-5Sil MS \u30ab\u30e9\u30e0\u306b\u3088\u308b\u691c\u51fa\u9650\u754c\u6539\u5584\u52b9\u679c<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">RMX-5Sil MS \u30ab\u30e9\u30e0\u3067\u306f\u3001\u8a55\u4fa1\u3057\u305f 52 \u5316\u5408\u7269\u306e\u3046\u3061 MDL \u306b\u304a\u3044\u3066 60%\uff0852\u6210\u5206\u4e2d31\u6210\u5206\uff09\u3001LLOQ \u306b\u304a\u3044\u3066 63%\uff0852\u6210\u5206\u4e2d33\u6210\u5206\uff09\u306e\u5316\u5408\u7269\u3067\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u3088\u308a\u4f4e\u3044\u5024\u304c\u5f97\u3089\u308c\u307e\u3057\u305f\uff08Table I, Figure 1, Figure 2\uff09\u3002\u3053\u308c\u306f\u3001TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u30ab\u30e9\u30e0\u8868\u9762\u306e\u6d3b\u6027\u90e8\u4f4d\u304c\u52b9\u679c\u7684\u306b\u6291\u5236\u3055\u308c\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3068\u5fdc\u7b54\u6027\u304c\u6539\u5584\u3057\u305f\u7d50\u679c\u3068\u3057\u3066\u3001\u3088\u308a\u9ad8\u3044\u611f\u5ea6\u304c\u5f97\u3089\u308c\u305f\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">\u7279\u306b\u3001\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u3068\u3044\u3063\u305f\u5316\u5b66\u7279\u6027\u306e\u7570\u306a\u308b\u5e45\u5e83\u3044\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u30af\u30e9\u30b9\u3067\u691c\u51fa\u9650\u754c\u304a\u3088\u3073\u5b9a\u91cf\u4e0b\u9650\u306e\u6539\u5584\u304c\u78ba\u8a8d\u3055\u308c\u307e\u3057\u305f\u3002\u5f93\u6765\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3067\u306f\u6027\u80fd\u304c\u4e0d\u5341\u5206\u3067\u3042\u3063\u305f\u96e3\u5206\u6790\u6027\u5316\u5408\u7269\u3092\u542b\u3081\u3001\u591a\u304f\u306e\u5e45\u5e83\u3044\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3067 RMX-5Sil MS\u30ab\u30e9\u30e0\u304c\u691c\u51fa\u611f\u5ea6\u306b\u304a\u3044\u3066\u512a\u4f4d\u306a\u7d50\u679c\u3092\u793a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"margin-top:4px;margin-bottom:4px\"><strong>Table I: <\/strong>\u4e0d\u6d3b\u6027\u5ea6\u306e\u9ad8\u3044RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u3088\u308a\u3082\u591a\u304f\u306e\u5316\u5408\u7269\u3067LLOQ \u304a\u3088\u3073 MDL \u304c\u6539\u5584\u3001<br>\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306e\u691c\u51fa\u9650\u754c\u306b\u304a\u3044\u3066\u512a\u4f4d\u306a\u7d50\u679c\u3092\u793a\u3057\u305f\u3002<\/p>\n\n\n<div style=\"overflow-x: auto; -webkit-overflow-scrolling: touch; margin: 16px 0;\">\n<table style=\"border-collapse: collapse; width: 100%; min-width: 860px; font-size: clamp(12px, 1.1vw, 14px); line-height: 1.25;\">\n<thead>\n<tr>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: left; background: #eef2f7; font-weight: bold;\" rowspan=\"2\">\u30ab\u30e9\u30e0<\/th>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #0b2a57; color: #fff; font-weight: bold;\" colspan=\"4\">LLOQ (ppb)<\/th>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #0b2a57; color: #fff; font-weight: bold;\" colspan=\"4\">MDL (ppb)<\/th>\n<\/tr>\n<tr>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #dfe7f3; font-weight: bold;\">\u5e73\u5747<\/th>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #dfe7f3; font-weight: bold;\">Min<\/th>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #dfe7f3; font-weight: bold;\">Max<\/th>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #dfe7f3; font-weight: bold;\">RMX-5Sil\u3067\u4e0b\u9650\u5024\u304c\u512a\u308c\u3066\u3044\u305f\u5316\u5408\u7269\u306e\u5272\u5408<\/th>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #dfe7f3; font-weight: bold;\">\u5e73\u5747<\/th>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #dfe7f3; font-weight: bold;\">Min<\/th>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #dfe7f3; font-weight: bold;\">Max<\/th>\n<th style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center; background: #dfe7f3; font-weight: bold;\">RMX-5Sil\u3067\u4e0b\u9650\u5024\u304c\u512a\u308c\u3066\u3044\u305f\u5316\u5408\u7269\u306e\u5272\u5408<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: left; font-weight: bold;\">RMX-5Sil MS<\/td>\n<p><!-- LLOQ --><\/p>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">14<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">1<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">100<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">52\u6210\u5206\u4e2d33\u6210\u5206 (63%)<\/td>\n<p><!-- MDL --><\/p>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">1<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">0.1<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">14<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">52\u6210\u5206\u4e2d31\u6210\u5206 (60%)<\/td>\n<\/tr>\n<tr>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: left;\">\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0<\/td>\n<p><!-- LLOQ --><\/p>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">19<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">1<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">100<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">\u30fc<\/td>\n<p><!-- MDL --><\/p>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">2<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">0.1<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">51<\/td>\n<td style=\"border: 1px solid #c9cdd3; padding: 10px 12px; text-align: center;\">\u30fc<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<\/div>\n\n\n<div style=\"height:62px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"margin-top:4px;margin-bottom:4px\"><strong>Table II: <\/strong>\u5404\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306b\u304a\u3051\u308b LOD \u304a\u3088\u3073 MDL \u306e\u7d50\u679c\uff08\u6fc3\u5ea6\u5358\u4f4d\uff1appb\uff09<br>\uff08\u9ec4\u8272\u30cf\u30a4\u30e9\u30a4\u30c8\u306fRMX-5Sil MS\u306e\u6027\u80fd\u304c\u512a\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u308b\uff09<\/p>\n\n\n\n<style>\n.rmx2-wrap{display:flex;flex-wrap:nowrap;gap:18px;align-items:flex-start;}\n@media (max-width: 900px){.rmx2-wrap{flex-wrap:wrap;}}\n.rmx2-panel{flex:1 1 0;min-width:0;}\ntable.rmx2{width:100%;border-collapse:collapse;table-layout:fixed;border:0 !important;outline:0 !important;font-family:inherit;}\ntable.rmx2 th, table.rmx2 td{border:1px solid #b9c3d1;padding:8px 10px;vertical-align:middle;}\ntable.rmx2 thead tr.top th{background:#0b2a55;color:#fff;font-weight:700;text-align:center;padding:6px 8px;line-height:1.15;font-size:15px;}\ntable.rmx2 thead tr.top th.spacer{background:transparent !important;border:0 !important;padding:0 !important;}\ntable.rmx2 thead tr.sub th{background:#dfe7f3;color:#0b2a55;font-weight:700;text-align:center;}\ntable.rmx2 thead tr.sub th.compound{text-align:left;border-top:0 !important;}\ntable.rmx2 tbody td{text-align:center;}\ntable.rmx2 tbody td.num{font-size:13px;}\ntable.rmx2 tbody td.compound{text-align:left;font-size:14px;line-height:1.2;word-break:normal;overflow-wrap:normal;hyphens:auto;}\ntable.rmx2 td.rmxhl{background:#f3dc9a;}\ntable.rmx2 col.c-comp{width:42%;}\ntable.rmx2 col.c-num{width:14.5%;}\n<\/style>\n\n<div class=\"rmx2-wrap\">\n\n  <!-- ===== LEFT TABLE ===== -->\n  <div class=\"rmx2-panel\">\n    <figure class=\"wp-block-table\">\n      <table class=\"rmx2\" aria-label=\"Table II (Left)\">\n        <colgroup>\n          <col class=\"c-comp\" \/>\n          <col class=\"c-num\" \/>\n          <col class=\"c-num\" \/>\n          <col class=\"c-num\" \/>\n          <col class=\"c-num\" \/>\n        <\/colgroup>\n        <thead>\n          <tr class=\"top\">\n            <th class=\"spacer\" aria-hidden=\"true\">&nbsp;<\/th>\n            <th colspan=\"2\">RMX-5Sil MS<\/th>\n            <th colspan=\"2\">Premium Competitor<br \/>Column<\/th>\n          <\/tr>\n          <tr class=\"sub\">\n            <th class=\"compound\">Compound<\/th>\n            <th>LLOQ<\/th><th>MDL<\/th><th>LLOQ<\/th><th>MDL<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td class=\"compound\">Acenaphthylene<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num rmxhl\">0.42<\/td><td class=\"num\">100<\/td><td class=\"num\">0.60<\/td><\/tr>\n          <tr><td class=\"compound\">Phenol<\/td><td class=\"num rmxhl\">2<\/td><td class=\"num\">0.45<\/td><td class=\"num\">20<\/td><td class=\"num\">0.27<\/td><\/tr>\n          <tr><td class=\"compound\">4-Nitroaniline<\/td><td class=\"num rmxhl\">2<\/td><td class=\"num rmxhl\">0.22<\/td><td class=\"num\">20<\/td><td class=\"num\">0.43<\/td><\/tr>\n          <tr><td class=\"compound\">2,4-Dimethylphenol<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">0.33<\/td><td class=\"num\">20<\/td><td class=\"num\">0.30<\/td><\/tr>\n          <tr><td class=\"compound\">2-Nitrophenol<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">0.84<\/td><td class=\"num\">20<\/td><td class=\"num\">0.51<\/td><\/tr>\n          <tr><td class=\"compound\">2-Methylphenol<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num rmxhl\">0.84<\/td><td class=\"num\">20<\/td><td class=\"num\">2.37<\/td><\/tr>\n          <tr><td class=\"compound\">Aniline<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">0.67<\/td><td class=\"num\">20<\/td><td class=\"num\">0.43<\/td><\/tr>\n          <tr><td class=\"compound\">Diphenylamine<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num rmxhl\">0.74<\/td><td class=\"num\">20<\/td><td class=\"num\">0.85<\/td><\/tr>\n          <tr><td class=\"compound\">Benz[a]anthracene<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num rmxhl\">0.29<\/td><td class=\"num\">20<\/td><td class=\"num\">0.49<\/td><\/tr>\n          <tr><td class=\"compound\">2-Fluorobiphenyl<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num rmxhl\">0.20<\/td><td class=\"num\">20<\/td><td class=\"num\">0.30<\/td><\/tr>\n          <tr><td class=\"compound\">2-Methylnaphthalene<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num rmxhl\">0.15<\/td><td class=\"num\">20<\/td><td class=\"num\">0.32<\/td><\/tr>\n          <tr><td class=\"compound\">Benzo[ghi]perylene<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">0.39<\/td><td class=\"num\">20<\/td><td class=\"num\">0.08<\/td><\/tr>\n          <tr><td class=\"compound\">Phenanthrene<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">0.19<\/td><td class=\"num\">20<\/td><td class=\"num\">0.15<\/td><\/tr>\n          <tr><td class=\"compound\">4-Nitrophenol<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num\">1.38<\/td><td class=\"num\">20<\/td><td class=\"num\">1.31<\/td><\/tr>\n          <tr><td class=\"compound\">3-Nitroaniline<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num\">1.40<\/td><td class=\"num\">20<\/td><td class=\"num\">1.33<\/td><\/tr>\n          <tr><td class=\"compound\">3,3&#39;-Dichlorobenzidine<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num rmxhl\">1.37<\/td><td class=\"num\">20<\/td><td class=\"num\">1.76<\/td><\/tr>\n          <tr><td class=\"compound\">N-Nitrosodimethylamine<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num\">0.63<\/td><td class=\"num\">20<\/td><td class=\"num\">0.53<\/td><\/tr>\n          <tr><td class=\"compound\">Nitrobenzene-d5<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num rmxhl\">0.13<\/td><td class=\"num\">20<\/td><td class=\"num\">0.74<\/td><\/tr>\n          <tr><td class=\"compound\">Acenaphthene<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num rmxhl\">0.93<\/td><td class=\"num\">20<\/td><td class=\"num\">1.53<\/td><\/tr>\n          <tr><td class=\"compound\">Benzo[b]fluoranthene<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num rmxhl\">0.71<\/td><td class=\"num\">20<\/td><td class=\"num\">1.31<\/td><\/tr>\n          <tr><td class=\"compound\">Benzo[k]fluoranthene<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num rmxhl\">0.67<\/td><td class=\"num\">20<\/td><td class=\"num\">2.65<\/td><\/tr>\n          <tr><td class=\"compound\">Benzo[a]pyrene<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num rmxhl\">1.08<\/td><td class=\"num\">20<\/td><td class=\"num\">2.63<\/td><\/tr>\n          <tr><td class=\"compound\">Fluorene<\/td><td class=\"num rmxhl\">10<\/td><td class=\"num rmxhl\">0.48<\/td><td class=\"num\">20<\/td><td class=\"num\">1.54<\/td><\/tr>\n          <tr><td class=\"compound\">2,4,6-Trichlorophenol<\/td><td class=\"num rmxhl\">1<\/td><td class=\"num\">0.40<\/td><td class=\"num\">10<\/td><td class=\"num\">0.16<\/td><\/tr>\n          <tr><td class=\"compound\">2,6-Dichlorophenol<\/td><td class=\"num rmxhl\">2<\/td><td class=\"num\">0.30<\/td><td class=\"num\">10<\/td><td class=\"num\">0.21<\/td><\/tr>\n          <tr><td class=\"compound\">p-Terphenyl-d14<\/td><td class=\"num rmxhl\">2<\/td><td class=\"num rmxhl\">0.30<\/td><td class=\"num\">10<\/td><td class=\"num\">0.36<\/td><\/tr>\n          <tr><td class=\"compound\">2,4,5-Trichlorophenol<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">0.92<\/td><td class=\"num\">10<\/td><td class=\"num\">0.33<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/figure>\n  <\/div>\n\n  <!-- ===== RIGHT TABLE ===== -->\n  <div class=\"rmx2-panel\">\n    <figure class=\"wp-block-table\">\n      <table class=\"rmx2\" aria-label=\"Table II (Right)\">\n        <colgroup>\n          <col class=\"c-comp\" \/>\n          <col class=\"c-num\" \/>\n          <col class=\"c-num\" \/>\n          <col class=\"c-num\" \/>\n          <col class=\"c-num\" \/>\n        <\/colgroup>\n        <thead>\n          <tr class=\"top\">\n            <th class=\"spacer\" aria-hidden=\"true\">&nbsp;<\/th>\n            <th colspan=\"2\">RMX-5Sil MS<\/th>\n            <th colspan=\"2\">Premium Competitor<br \/>Column<\/th>\n          <\/tr>\n          <tr class=\"sub\">\n            <th class=\"compound\">Compound<\/th>\n            <th>LLOQ<\/th><th>MDL<\/th><th>LLOQ<\/th><th>MDL<\/th>\n          <\/tr>\n        <\/thead>\n        <tbody>\n          <tr><td class=\"compound\">2,3,4,6-Tetrachlorophenol<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">1.52<\/td><td class=\"num\">10<\/td><td class=\"num\">1.48<\/td><\/tr>\n          <tr><td class=\"compound\">4-Chloro-3-methylphenol<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num rmxhl\">0.06<\/td><td class=\"num\">10<\/td><td class=\"num\">0.21<\/td><\/tr>\n          <tr><td class=\"compound\">Pentachlorophenol<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num rmxhl\">0.18<\/td><td class=\"num\">10<\/td><td class=\"num\">0.93<\/td><\/tr>\n          <tr><td class=\"compound\">4-Chloroaniline<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">0.55<\/td><td class=\"num\">10<\/td><td class=\"num\">0.32<\/td><\/tr>\n          <tr><td class=\"compound\">o-Nitroaniline<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">0.49<\/td><td class=\"num\">10<\/td><td class=\"num\">0.36<\/td><\/tr>\n          <tr><td class=\"compound\">1-Methylnaphthalene<\/td><td class=\"num rmxhl\">1<\/td><td class=\"num\">0.13<\/td><td class=\"num\">2<\/td><td class=\"num\">0.05<\/td><\/tr>\n          <tr><td class=\"compound\">2-Chlorophenol<\/td><td class=\"num\">1<\/td><td class=\"num\">0.55<\/td><td class=\"num\">1<\/td><td class=\"num\">0.47<\/td><\/tr>\n          <tr><td class=\"compound\">2,4,6-Tribromophenol<\/td><td class=\"num\">20<\/td><td class=\"num rmxhl\">1.79<\/td><td class=\"num\">20<\/td><td class=\"num\">3.79<\/td><\/tr>\n          <tr><td class=\"compound\">2,4-Dichlorophenol<\/td><td class=\"num\">1<\/td><td class=\"num rmxhl\">0.32<\/td><td class=\"num\">1<\/td><td class=\"num\">0.41<\/td><\/tr>\n          <tr><td class=\"compound\">2,4-Dinitrophenol<\/td><td class=\"num\">20<\/td><td class=\"num rmxhl\">1.94<\/td><td class=\"num\">20<\/td><td class=\"num\">2.34<\/td><\/tr>\n          <tr><td class=\"compound\">2-Fluorophenol<\/td><td class=\"num\">1<\/td><td class=\"num\">0.20<\/td><td class=\"num\">1<\/td><td class=\"num\">0.20<\/td><\/tr>\n          <tr><td class=\"compound\">3- and 4-Methylphenol<\/td><td class=\"num\">20<\/td><td class=\"num rmxhl\">0.59<\/td><td class=\"num\">20<\/td><td class=\"num\">0.69<\/td><\/tr>\n          <tr><td class=\"compound\">Benzoic acid<\/td><td class=\"num\">100<\/td><td class=\"num rmxhl\">14.47<\/td><td class=\"num\">100<\/td><td class=\"num\">50.54<\/td><\/tr>\n          <tr><td class=\"compound\">Phenol-d6<\/td><td class=\"num\">1<\/td><td class=\"num rmxhl\">0.29<\/td><td class=\"num\">1<\/td><td class=\"num\">0.32<\/td><\/tr>\n          <tr><td class=\"compound\">Benzidine<\/td><td class=\"num\">100<\/td><td class=\"num rmxhl\">0.89<\/td><td class=\"num\">100<\/td><td class=\"num\">0.97<\/td><\/tr>\n          <tr><td class=\"compound\">Chrysene<\/td><td class=\"num\">5<\/td><td class=\"num\">0.30<\/td><td class=\"num\">5<\/td><td class=\"num\">0.23<\/td><\/tr>\n          <tr><td class=\"compound\">Pyrene<\/td><td class=\"num\">5<\/td><td class=\"num\">1.03<\/td><td class=\"num\">5<\/td><td class=\"num\">0.10<\/td><\/tr>\n          <tr><td class=\"compound\">Dibenz[a,h]anthracene<\/td><td class=\"num\">20<\/td><td class=\"num rmxhl\">1.06<\/td><td class=\"num\">20<\/td><td class=\"num\">2.58<\/td><\/tr>\n          <tr><td class=\"compound\">Indeno[1,2,3-cd]pyrene<\/td><td class=\"num\">20<\/td><td class=\"num rmxhl\">0.59<\/td><td class=\"num\">20<\/td><td class=\"num\">1.81<\/td><\/tr>\n          <tr><td class=\"compound\">Naphthalene<\/td><td class=\"num\">1<\/td><td class=\"num rmxhl\">0.18<\/td><td class=\"num\">1<\/td><td class=\"num\">0.35<\/td><\/tr>\n          <tr><td class=\"compound\">Fluoranthene<\/td><td class=\"num\">20<\/td><td class=\"num rmxhl\">0.16<\/td><td class=\"num\">20<\/td><td class=\"num\">0.80<\/td><\/tr>\n        <tr><td class=\"compound\">Anthracene<\/td><td class=\"num rmxhl\">5<\/td><td class=\"num\">0.86<\/td><td class=\"num\">1<\/td><td class=\"num\">0.45<\/td><\/tr>\n\n<tr><td class=\"compound\">4,6-Dinitro-2-methylphenol<\/td><td class=\"num rmxhl\">50<\/td><td class=\"num rmxhl\">1.59<\/td><td class=\"num\">10<\/td><td class=\"num\">1.80<\/td><\/tr>\n\n<tr><td class=\"compound\">Dinoseb<\/td><td class=\"num rmxhl\">50<\/td><td class=\"num rmxhl\">2.23<\/td><td class=\"num\">10<\/td><td class=\"num\">3.39<\/td><\/tr>\n\n<tr><td class=\"compound\">Pyridine<\/td><td class=\"num rmxhl\">100<\/td><td class=\"num rmxhl\">7.73<\/td><td class=\"num\">20<\/td><td class=\"num\">11.33<\/td><\/tr>\n        <\/tbody>\n      <\/table>\n    <\/figure>\n  <\/div>\n\n<\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 1:<\/strong> RMX-5Sil MS \u30ab\u30e9\u30e0\u3068\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u306b\u304a\u3051\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e MDL \u6bd4\u8f03\uff08\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u5316\u5408\u7269\u306b\u30b0\u30eb\u30fc\u30d7\u5206\u3051\uff09<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"701\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-01.jpg\" alt=\"RMX-5Sil MS \u30ab\u30e9\u30e0\u3068\u7af6\u5408\u30ab\u30e9\u30e0\u306e MDL \u6bd4\u8f03\u30b0\u30e9\u30d5\" class=\"wp-image-63795\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-01.jpg 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-01-300x157.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-01-1024x536.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-01-768x402.jpg 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/figure>\n<\/div>\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Figure 2:<\/strong> RMX-5Sil MS \u30ab\u30e9\u30e0\u3068\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u306b\u304a\u3051\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e LLOQ \u6bd4\u8f03\uff08\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u5316\u5408\u7269\u306b\u30b0\u30eb\u30fc\u30d7\u5206\u3051\uff09<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1340\" height=\"701\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-02.jpg\" alt=\"RMX-5Sil MS \u30ab\u30e9\u30e0\u3068\u7af6\u5408\u30ab\u30e9\u30e0\u306e LLOQ \u6bd4\u8f03\u30b0\u30e9\u30d5\" class=\"wp-image-63802\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-02.jpg 1340w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-02-300x157.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-02-1024x536.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/figure-EVAN5255-02-768x402.jpg 768w\" sizes=\"auto, (max-width: 1340px) 100vw, 1340px\" \/><\/figure>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-medium-font-size\"><strong>Conclusion\uff5cRMX-5Sil MS\u30ab\u30e9\u30e0\u306b\u3088\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306e\u307e\u3068\u3081<\/strong><\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">\u4e0d\u6d3b\u6027\u306a\u30b5\u30f3\u30d7\u30eb\u6d41\u8def\u306f\u3001\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u691c\u51fa\u611f\u5ea6\u3092\u6539\u5584\u3057\u3001\u5fae\u91cf\u5206\u6790\u3092\u53ef\u80fd\u3068\u3057\u307e\u3059\u3002\u307e\u305f\u3001GC-MS\/MS \u304c\u672c\u6765\u6301\u3064\u9ad8\u611f\u5ea6\u6027\u80fd\u3092\u6700\u5927\u9650\u306b\u5f15\u304d\u51fa\u3059\u305f\u3081\u306b\u6975\u3081\u3066\u91cd\u8981\u306a\u8981\u7d20\u3068\u306a\u308a\u307e\u3059\u3002\u672c\u691c\u8a0e\u7d50\u679c\u304b\u3089\u3001\u975e\u5e38\u306b\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u6301\u3064 RMX-5Sil MS \u30ab\u30e9\u30e0\u306f\u3001\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u512a\u308c\u305f\u611f\u5ea6\u3092\u63d0\u4f9b\u3059\u308b\u3060\u3051\u3067\u306a\u304f\u3001MDL \u304a\u3088\u3073 LLOQ \u306e\u53cc\u65b9\u306b\u304a\u3044\u3066\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u304a\u3044\u3066\u691c\u51fa\u9650\u754c\u5024\u30fb\u5b9a\u91cf\u4e0b\u9650\u5024\u3092\u6539\u5584\u3059\u308b\u3053\u3068\u304c\u793a\u3055\u308c\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image74586_8330c2-81:not(.kb-image-is-ratio-size) .kb-img, .kb-image74586_8330c2-81.kb-image-is-ratio-size{padding-right:50px;padding-left:50px;}.kb-image74586_8330c2-81 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image74586_8330c2-81\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/discover.restek.com\/ja\/rmx\/\" class=\"kb-advanced-image-link\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1014\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-1024x1014.png\" alt=\"GC\u30ab\u30e9\u30e0, \u4e0d\u6d3b\u6027, \u4f4e\u5438\u7740\" class=\"kb-img wp-image-81470\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-1024x1014.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-300x297.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-150x150.png 150w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-768x760.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-1536x1521.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-2048x2027.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><figcaption>\u30ab\u30e9\u30e0\u5185\u306e\u6d3b\u6027\u70b9\u3092\u6291\u3048\u305f\u3001\u9ad8\u611f\u5ea6\u30fb\u9577\u5bff\u547d\u306a\u30ab\u30e9\u30e0<\/figcaption><\/figure><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u95a2\u9023\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">                                \u30ab\u30bf\u30ed\u30b0No. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23267\">                                \u30ab\u30bf\u30ed\u30b0No. 23267                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Precision Inlet Liner, 4.0 mm x 6.3 x 78.5, for Thermo TRACE 1300\/1310, 1600\/1610 GCs w\/SSL Inlets, Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23267\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31618\">                                \u30ab\u30bf\u30ed\u30b0No. 31618                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">8270 Calibration Mix #1, 2000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31618\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31619\">                                \u30ab\u30bf\u30ed\u30b0No. 31619                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">8270 Calibration Mix #2, 2000 \u00b5g\/mL, Methylene Chloride:Methanol (85:15), 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31619\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31995\">                                \u30ab\u30bf\u30ed\u30b0No. 31995                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">8270 Calibration Mix #5, Revised, 2000 \u00b5g\/mL ea. in Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31995\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">                                \u30ab\u30bf\u30ed\u30b0No. 31025                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Acid Surrogate Mix (4\/89 SOW), 2000 \u00b5g\/mL, Methanol, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31025\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">                                \u30ab\u30bf\u30ed\u30b0No. 31024                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Base Neutral Surrogate Mix (4\/89 SOW), 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31024\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">                                \u30ab\u30bf\u30ed\u30b0No. 31886                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Revised SV Internal Standard Mix, 4000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31886\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31615\">                                \u30ab\u30bf\u30ed\u30b0No. 31615                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">GC-MS Tuning Mix, 1000 \u00b5g\/mL, Methylene Chloride, 1 mL\/ampul<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/31615\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image74586_b451dd-9a:not(.kb-image-is-ratio-size) .kb-img, .kb-image74586_b451dd-9a.kb-image-is-ratio-size{padding-right:100px;padding-left:100px;}.kb-image74586_b451dd-9a .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image74586_b451dd-9a\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-sales-JP\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"169\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-1024x169.jpg\" alt=\"\u304a\u554f\u3044\u5408\u308f\u305b\uff5cRestek\" class=\"kb-img wp-image-81960\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-1024x169.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-300x50.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-768x127.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-1536x254.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-2048x339.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<p class=\"wp-block-paragraph\"><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306eGC-MS\u5fae\u91cf\u5206\u6790\u306b\u304a\u3051\u308b\u691c\u51fa\u9650\u754c\u30fb\u5b9a\u91cf\u4e0b\u9650\u6539\u5584\u306e\u30dd\u30a4\u30f3\u30c8 Key Highlights Abstract\uff5c\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306e\u691c\u51fa\u9650\u754c\u3068TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306e\u5f71\u97ff \u672c\u7814\u7a76\u3067\u306f\u3001GC \u30ab\u30e9\u30e0\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u304c GC-MS\/MS \u306b\u3088\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u5206\u6790\u306e\u691c\u51fa\u9650\u754c\u306b\u3069\u306e\u3088\u3046\u306a\u5f71\u97ff\u3092\u4e0e\u3048\u308b\u304b\u3092\u8a55\u4fa1\u3057\u307e\u3057\u305f\u3002RMX-5Sil MS\u30ab\u30e9\u30e0\u3068\u7af6\u5408\u3059\u308b\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u3092\u6bd4\u8f03\u3057\u305f\u3068\u3053\u308d\u3001RMX-5Sil MS \u30ab\u30e9\u30e0\u306f\u8a55\u4fa1\u3057\u305f\u5316\u5408\u7269\u306e\u304a\u3088\u305d 3 \u5206\u306e 2 \u3067\u3001\u3088\u308a\u512a\u308c\u305f MDL\u304a\u3088\u3073 LLOQ\u3092\u793a\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306f\u3001TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u8868\u9762\u306e\u6d3b\u6027\u90e8\u4f4d\u304c\u52b9\u679c\u7684\u306b\u6291\u5236\u3055\u308c\u3001\u5e83\u7bc4\u306a\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u3067\u9ad8\u3044\u5fdc\u7b54\u3068\u5b89\u5b9a\u3057\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5f97\u3089\u308c\u305f\u305f\u3081\u3067\u3059\u3002\u672c\u8a66\u9a13\u3067\u306f\u6eb6\u5a92\u30d9\u30fc\u30b9\u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u7528\u3044\u3066\u304a\u308a\u3001\u524d\u51e6\u7406\u3084\u62bd\u51fa\u306e\u5f71\u97ff\u3092\u6392\u9664\u3057\u305f\u3046\u3048\u3067\u30ab\u30e9\u30e0\u672c\u6765\u306e\u6027\u80fd\u5dee\u3092\u660e\u78ba\u306b\u8a55\u4fa1\u3057\u3066\u3044\u307e\u3059\u3002 Introduction\uff5cSVOC\u306eGC-MS\/MS\u5206\u6790\u3068\u691c\u51fa\u611f\u5ea6\uff08MDL\u30fbLLOQ\uff09 \u74b0\u5883\u4e2d\u306b\u5fae\u91cf\u3067\u5b58\u5728\u3059\u308b\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\uff08SVOC\uff09\u306e\u6b63\u78ba\u306a\u5b9a\u91cf\u306f\u3001\u6c5a\u67d3\u306e\u628a\u63e1\u3084\u898f\u5236\u9075\u5b88\u3001\u3055\u3089\u306b\u306f\u4eba\u3068\u751f\u614b\u7cfb\u306e\u30ea\u30b9\u30af\u8a55\u4fa1\u306b\u304a\u3044\u3066\u91cd\u8981\u3067\u3059\u3002GC-MS\/MS \u306f\u9ad8\u3044\u9078\u629e\u6027\u3068\u611f\u5ea6\u3092\u5099\u3048\u3066\u304a\u308a\u3001SVOC \u5206\u6790\u306e\u30e1\u30bd\u30c3\u30c9\u691c\u51fa\u9650\u754c\uff08MDL\uff09\u304a\u3088\u3073\u5b9a\u91cf\u4e0b\u9650\uff08LLOQ\uff09\u3092\u6539\u5584\u3059\u308b\u305f\u3081\u306e\u4e3b\u8981\u306a\u5206\u6790\u6280\u8853\u3068\u3057\u3066\u5e83\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u9ad8\u611f\u5ea6\u306a\u30e1\u30bd\u30c3\u30c9\u306b\u3088\u308a\u3001\u8a66\u9a13\u5ba4\u306f\u62bd\u51fa\u91cf\u3092\u5c11\u306a\u304f\u3057\u305f\u30b5\u30f3\u30d7\u30eb\u524d\u51e6\u7406\u6cd5\u3092\u63a1\u7528\u3057\u3001\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3\u306a\u3069\u5869\u7d20\u7cfb\u6eb6\u5a92\u306e\u4f7f\u7528\u91cf\u524a\u6e1b\u3092\u56f3\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002 \u62bd\u51fa\u91cf\u3092\u6e1b\u3089\u3059\u4f4e\u5bb9\u91cf\u62bd\u51fa\u6cd5\u306f\u3001\u64cd\u4f5c\u304c\u7c21\u4fbf\u3067\u6eb6\u5a92\u4f7f\u7528\u91cf\u3092\u6291\u3048\u3089\u308c\u308b\u4e00\u65b9\u3001\u51e6\u7406\u3059\u308b\u8a66\u6599\u91cf\u304c\u5c11\u306a\u3044\u305f\u3081\u3001\u62bd\u51fa\u6db2\u306b\u542b\u307e\u308c\u308b\u5206\u6790\u5bfe\u8c61\u7269\u8cea\u306e\u7dcf\u91cf\u304c\u5f93\u6765\u6cd5\u3088\u308a\u5c11\u306a\u304f\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u62bd\u51fa\u6db2\u4e2d\u306e\u30bf\u30fc\u30b2\u30c3\u30c8\u6fc3\u5ea6\u306f\u4f4e\u304f\u306a\u308a\u3001\u5206\u6790\u5074\u306b\u306f\u3088\u308a\u9ad8\u3044\u611f\u5ea6\u304c\u6c42\u3081\u3089\u308c\u307e\u3059\u3002\u3053\u306e\u80cc\u666f\u304b\u3089\u3001GC-MS\/MS \u306b\u3088\u308b\u9ad8\u611f\u5ea6\u691c\u51fa\u306e\u9700\u8981\u304c\u9ad8\u307e\u3063\u3066\u3044\u307e\u3059\u3002 \u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306f\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u306a\u3069\u591a\u69d8\u306a\u5316\u5b66\u7279\u6027\u3092\u6301\u3061\u3001\u305d\u306e\u4e00\u90e8\u306f\u5206\u6790\u4e2d\u306b\u30ab\u30e9\u30e0\u8868\u9762\u306e\u6d3b\u6027\u90e8\u4f4d\uff08\u4f8b\uff1a\u30b7\u30e9\u30ce\u30fc\u30eb\uff09\u3068\u76f8\u4e92\u4f5c\u7528\u3057\u3001\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u3084\u5fdc\u7b54\u4f4e\u4e0b\u3092\u5f15\u304d\u8d77\u3053\u3057\u307e\u3059\u3002\u3053\u3046\u3057\u305f\u8ab2\u984c\u3092\u514b\u670d\u3059\u308b\u305f\u3081\u306b\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306e\u6d41\u8def\uff08sample flow path\uff09\u5168\u4f53\u3067\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u304c\u78ba\u4fdd\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002GC \u30ab\u30e9\u30e0\u30e1\u30fc\u30ab\u30fc\u5404\u793e\u306f\u3001\u30ab\u30e9\u30e0\u8868\u9762\u3092\u4e2d\u6027\u5316\u3057\u3066\u30d4\u30fc\u30af\u5f62\u72b6\u60aa\u5316\u3084\u611f\u5ea6\u4f4e\u4e0b\u306e\u539f\u56e0\u3068\u306a\u308b\u76f8\u4e92\u4f5c\u7528\u3092\u6291\u5236\u3059\u308b\u305f\u3081\u3001\u3055\u307e\u3056\u307e\u306a\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u5f93\u6765\u306e\u51e6\u7406\u3067\u306f\u7279\u5b9a\u306e\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u306e\u307f\u5341\u5206\u306a\u52b9\u679c\u304c\u5f97\u3089\u308c\u305f\u3068\u3057\u3066\u3082\u3001\u5e45\u5e83\u3044\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u4e07\u904d\u306a\u304f\u52b9\u679c\u3092\u5f97\u308b\u3053\u3068\u306f\u6975\u3081\u3066\u96e3\u3057\u3044\u8ab2\u984c\u3068\u3057\u3066\u6b8b\u3063\u3066\u3044\u307e\u3057\u305f\u3002 Restek\u306fRMX \u30ab\u30e9\u30e0\u30b7\u30ea\u30fc\u30ba\u306b\u6b21\u4e16\u4ee3TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3092\u63a1\u7528\u3057\u3001\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u306e\u3044\u305a\u308c\u306e\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u3082\u5e83\u304f\u6709\u52b9\u306a\u4e0d\u6d3b\u6027\u8868\u9762\u3092\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002\u672c\u7814\u7a76\u3067\u306f\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u3068\u7af6\u5408\u30d7\u30ec\u30df\u30a2\u30e0\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066\u3001MDL \u304a\u3088\u3073 LLOQ \u3092\u8a55\u4fa1\u3057\u3001\u9054\u6210\u3067\u304d\u308b\u691c\u51fa\u9650\u754c\u304a\u3088\u3073\u5b9a\u91cf\u4e0b\u9650\u306e\u5dee\u3092\u6bd4\u8f03\u3057\u307e\u3057\u305f\u3002\u30b5\u30f3\u30d7\u30eb\u30de\u30c8\u30ea\u30af\u30b9\u306e\u5f71\u97ff\u3092\u6392\u9664\u3057\u3066\u30ab\u30e9\u30e0\u6027\u80fd\u305d\u306e\u3082\u306e\u3092\u8a55\u4fa1\u3059\u308b\u305f\u3081\u3001\u5b9f\u9a13\u306b\u306f\u6eb6\u5a92\u30d9\u30fc\u30b9\u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u7528\u3044\u3066\u3044\u307e\u3059\u3002 Experimental\uff5cRMX-5Sil MS \u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f GC-MS\/MS \u5206\u6790\u6761\u4ef6 Standard and Sample Preparation\uff5c \u6a19\u6e96\u6eb6\u6db2\u304a\u3088\u3073\u30b5\u30f3\u30d7\u30eb\u8abf\u88fd \u691c\u91cf\u7dda\u6a19\u6e96\u6eb6\u6db2\u306f\u30b8\u30af\u30ed\u30ed\u30e1\u30bf\u30f3\u3067 0.5\u30011\u30012\u30015\u300110\u300120\u300150\u3001100\u3001200\u3001500\u30011000\u30012000\u30015000 ppb \u306e\u6fc3\u5ea6\u3067\u8abf\u88fd\u3057\u307e\u3057\u305f\u3002\u4e21\u30ab\u30e9\u30e0\u306b\u3064\u3044\u3066 Day1 \u306b\u691c\u91cf\u7dda\u3092\u4f5c\u6210\u3057\u30010.5\u301c100 ppb \u306e\u6a19\u6e96\u6eb6\u6db2\u3092\u5404\u6fc3\u5ea6 3 \u56de\u305a\u3064\u6ce8\u5165\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5404\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269\u306b\u304a\u3051\u308b\u76f4\u7dda\u7684\u306a\u691c\u91cf\u7bc4\u56f2\u3092\u5fdc\u7b54\u304b\u3089\u6c7a\u5b9a\u3057\u307e\u3057\u305f\u3002Day2 \u304a\u3088\u3073 Day3&#8230;<\/p>\n","protected":false},"author":34,"featured_media":62686,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"default","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"[]","_ppma_block_editor_authors":""},"categories":[785],"tags":[2727,2728,2726,2729,2730],"industries-application":[2271],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[],"ppma_author":[454,441,2657,452],"class_list":["post-74586","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes-ja","tag-gc-ms","tag-2728","tag-2726","tag-2729","tag-2730","industries-application-environmental-ja"],"acf":[],"taxonomy_info":{"category":[{"value":785,"label":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3"}],"post_tag":[{"value":2727,"label":"GC-MS"},{"value":2728,"label":"\u5206\u6790\u6761\u4ef6"},{"value":2726,"label":"\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269"},{"value":2729,"label":"\u5fae\u91cf\u5206\u6790"},{"value":2730,"label":"\u9ad8\u611f\u5ea6\u5206\u6790"}],"industries-application":[{"value":2271,"label":"\u74b0\u5883 \u5206\u6790"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-EVAN5255-1024x536.jpg",1024,536,true],"author_info":{"display_name":"Erica Pack, PhD","author_link":"https:\/\/discover.restek.com\/ja\/author\/erica-pack-phd\/"},"comment_info":0,"category_info":[{"term_id":785,"name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","slug":"application-notes-ja","term_group":0,"term_taxonomy_id":785,"taxonomy":"category","description":"","parent":0,"count":88,"filter":"raw","cat_ID":785,"category_count":88,"category_description":"","cat_name":"\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3","category_nicename":"application-notes-ja","category_parent":0}],"tag_info":[{"term_id":2727,"name":"GC-MS","slug":"gc-ms","term_group":0,"term_taxonomy_id":2727,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2728,"name":"\u5206\u6790\u6761\u4ef6","slug":"%e5%88%86%e6%9e%90%e6%9d%a1%e4%bb%b6","term_group":0,"term_taxonomy_id":2728,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2726,"name":"\u534a\u63ee\u767a\u6027\u6709\u6a5f\u5316\u5408\u7269","slug":"%e5%8d%8a%e6%8f%ae%e7%99%ba%e6%80%a7%e6%9c%89%e6%a9%9f%e5%8c%96%e5%90%88%e7%89%a9","term_group":0,"term_taxonomy_id":2726,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2729,"name":"\u5fae\u91cf\u5206\u6790","slug":"%e5%be%ae%e9%87%8f%e5%88%86%e6%9e%90","term_group":0,"term_taxonomy_id":2729,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2730,"name":"\u9ad8\u611f\u5ea6\u5206\u6790","slug":"%e9%ab%98%e6%84%9f%e5%ba%a6%e5%88%86%e6%9e%90","term_group":0,"term_taxonomy_id":2730,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"authors":[{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":441,"user_id":21,"is_guest":0,"slug":"chris-english","display_name":"Chris English","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-english-chris.png"},"author_category":"1","first_name":"Chris","last_name":"English","user_url":"https:\/\/www.linkedin.com\/in\/chris-english-28214912\/","job_title":"Sr. R&D Manager","description":"Since 2004, Chris has managed a team of chemists in Restek's innovations laboratory who perform new product testing, method development, and applications work. Before taking the reins of our lab, he spent seven years as an environmental chemist and was critical to the development of Restek\u2019s current line of volatile GC columns. Prior to joining Restek, he operated a variety of gas chromatographic detectors conducting method development and sample analysis. Chris holds a BS in environmental science from Saint Michael's College."},{"term_id":2657,"user_id":70,"is_guest":0,"slug":"ramkumar-dhandapani-phd","display_name":"Ramkumar Dhandapani, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg"},"author_category":"1","first_name":"Ramkumar","last_name":"Dhandapani","user_url":"https:\/\/www.linkedin.com\/in\/dr-ramkumar-dhandapani-b9012424\/?skipRedirect=true&enhance=null","job_title":"Director of Product Management","description":"Dr. Ramkumar Dhandapani\u00a0is a seasoned analytical chemist with over\u00a023 years of experience\u00a0in the chromatography industry and a Ph.D. in analytical chemistry. During his career, he has specialized in method development, validation, and the troubleshooting of chromatography methods. He has developed numerous regulatory-compliant methods across diverse sectors, including\u00a0environmental analysis, food quality and safety, pharmaceutical, fuels, and chemical industries. Currently, Dr. Dhandapani is the Director of Product Management at Restek, he is keen on innovation in chromatography and scaling breakthrough innovations\u00a0to market as commercial products."},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/74586","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/34"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=74586"}],"version-history":[{"count":145,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/74586\/revisions"}],"predecessor-version":[{"id":104980,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/74586\/revisions\/104980"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/62686"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=74586"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=74586"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=74586"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=74586"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=74586"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=74586"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=74586"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=74586"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=74586"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}