{"id":79652,"date":"2026-01-26T12:37:22","date_gmt":"2026-01-26T12:37:22","guid":{"rendered":"https:\/\/discover.restek.com\/?p=79652"},"modified":"2026-05-17T23:51:22","modified_gmt":"2026-05-17T23:51:22","slug":"seized-drug-identification-by-gc-ms-ja","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/articles-ja\/cffa4918-ja\/seized-drug-identification-by-gc-ms-ja","title":{"rendered":"GC-MS\u3092\u6d3b\u7528\u3057\u305f\u62bc\u53ce\u85ac\u7269\u306e\u540c\u5b9a\u7cbe\u5ea6\u3068\u4fe1\u983c\u6027\u306e\u5411\u4e0a"},"content":{"rendered":"\n<div style=\"height:98px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:1.5rem\">Key Higlights<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"font-size:1.2rem\">\u6b21\u4e16\u4ee3\u306eTriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306f\u3001\u5b89\u5b9a\u3057\u305f\u4e2d\u6027\u8868\u9762\u3092\u5f62\u6210\u3057\u3001\u5e45\u5e83\u3044\u85ac\u7269\u30af\u30e9\u30b9\u306b\u5bfe\u3057\u3066\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u5b9f\u73fe<\/li>\n\n\n\n<li style=\"font-size:1.2rem\">\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u306b\u3088\u308a\u3001\u5206\u6790\u304c\u96e3\u3057\u3044\u85ac\u7269\u3067\u3082\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u304c\u6539\u5584<\/li>\n\n\n\n<li style=\"font-size:1.2rem\">\u5b89\u5b9a\u3057\u305f\u5bfe\u79f0\u30d4\u30fc\u30af\u306b\u3088\u308a\u3001\u554f\u984c\u3068\u306a\u308a\u3084\u3059\u3044\u85ac\u7269\u306b\u304a\u3044\u3066\u3082\u3001\u3088\u308a\u6b63\u78ba\u306a\u540c\u5b9a\u304c\u53ef\u80fd\u306b<\/li>\n<\/ul>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:1.2rem\">Introduction\uff5c\u62bc\u53ce\u85ac\u7269\u5206\u6790\u306b\u304a\u3051\u308bGC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u91cd\u8981\u6027<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:1rem\">\u62bc\u53ce\u85ac\u7269\u3092\u6271\u3046\u5206\u6790\u6a5f\u95a2\u3067\u306f\u3001\u672a\u77e5\u306e\u8a66\u6599\u304c\u9055\u6cd5\u85ac\u7269\u3067\u3042\u308b\u304b\u3092\u5224\u5b9a\u3059\u308b\u305f\u3081\u306b\u3001GC-MS\u5206\u6790\u304c\u65e5\u5e38\u7684\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u969b\u3001GC\u30ab\u30e9\u30e0\u306e\u9078\u629e\u306f\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u304a\u3088\u3073\u5206\u6790\u6cd5\u306e\u4fe1\u983c\u6027\u3092\u5de6\u53f3\u3059\u308b\u91cd\u8981\u306a\u8981\u7d20\u3068\u306a\u308a\u307e\u3059\u3002\u85ac\u7269\u5206\u6790\u3067\u306f\u3001\u975e\u5e38\u306b\u591a\u69d8\u306a\u5316\u5b66\u69cb\u9020\u3092\u3082\u3064\u5316\u5408\u7269\u3092\u540c\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u305f\u3081\u3001\u300c5 \u7cfb\u300d\u30ab\u30e9\u30e0\u306b\u4ee3\u8868\u3055\u308c\u308b\u5fae\u6975\u6027\u30ab\u30e9\u30e0\u304c\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002<br>\u30b7\u30e9\u30ea\u30ec\u30f3\u30dd\u30ea\u30de\u30fc\u3092\u7528\u3044\u305f\u300c5Sil \u7cfb\u300d\u56fa\u5b9a\u76f8\u306f\u3001\u5f93\u6765\u306e5 \u7cfb\u30ab\u30e9\u30e0\u3092\u69cb\u9020\u7684\u306b\u6539\u826f\u3057\u305f\u3082\u306e\u3067\u3042\u308a\u3001\u3088\u308a\u9ad8\u3044\u8010\u71b1\u6027\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u8cea\u91cf\u5206\u6790\u8a08\u3068\u7d44\u307f\u5408\u308f\u305b\u305f\u969b\u306b\u3082\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u9577\u671f\u9593\u7dad\u6301\u3067\u304d\u308b\u3053\u3068\u304b\u3089\u3001\u85ac\u7269\u5206\u6790\u7528\u9014\u306b\u9069\u3057\u305f\u9078\u629e\u80a2\u3068\u3044\u3048\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5e45\u5e83\u3044\u85ac\u7269\u3092\u4e00\u6589\u306b\u5206\u6790\u3059\u308b\u5834\u5408\u3001\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u3088\u3063\u3066\u6319\u52d5\u306b\u5dee\u304c\u751f\u3058\u3001\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u3084\u4fdd\u6301\u6642\u9593\u306e\u305a\u308c\u306b\u3088\u3063\u3066\u3001\u85ac\u7269\u540c\u5b9a\u304c\u8907\u96d1\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:1.2rem\">\u306a\u305c\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5d29\u308c\u308b\u306e\u304b\uff5c\u30b7\u30e9\u30ce\u30fc\u30eb\u76f8\u4e92\u4f5c\u7528\u3068\u5438\u7740<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:1rem\">\u9178\u6027\u5316\u5408\u7269\u306e\u4e00\u90e8\u3001\u4f8b\u3048\u3070\u30d0\u30eb\u30d3\u30c4\u30fc\u30eb\u9178\u7cfb\u5316\u5408\u7269\u3067\u306f\u3001\u5f31\u9178\u6027\u306eN\u2013H\u57fa\u3068 GC\u30ab\u30e9\u30e0\u8868\u9762\u306b\u5b58\u5728\u3059\u308b\u30b7\u30e9\u30ce\u30fc\u30eb\u3068\u306e\u9593\u306b\u767a\u751f\u3059\u308b\u5f37\u3044\u76f8\u4e92\u4f5c\u7528\u306b\u3088\u308a\u3001\u56fa\u5b9a\u76f8\u3078\u306e\u5206\u914d\u304c\u4e0d\u5747\u4e00\u306b\u306a\u308a\u3084\u3059\u3044\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u30a2\u30df\u30f3\u985e\u306e\u3088\u3046\u306a\u5869\u57fa\u6027\u5b98\u80fd\u57fa\u3092\u3082\u3064\u85ac\u7269\u3067\u306f\u3001\u30ab\u30e9\u30e0\u8868\u9762\u3068\u306e\u6c34\u7d20\u7d50\u5408\u306b\u3088\u308a\u3001\u56fa\u5b9a\u76f8\u304b\u3089\u6eb6\u51fa\u304c\u9045\u308c\u305f\u308a\u3001\u5834\u5408\u306b\u3088\u3063\u3066\u306f\u5316\u5408\u7269\u304c\u8868\u9762\u306b\u5b8c\u5168\u306b\u5438\u7740\u3055\u308c\u3066\u3057\u307e\u3046\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001GC\u30ab\u30e9\u30e0\u8868\u9762\u306b\u5b58\u5728\u3059\u308b\u30b7\u30e9\u30ce\u30fc\u30eb\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u3092\u6291\u5236\u3067\u304d\u308c\u3070\u3001\u5b98\u80fd\u57fa\u306e\u7570\u306a\u308b\u5e45\u5e83\u3044\u85ac\u7269\u306b\u304a\u3044\u3066\u3001\u7279\u306b\u5206\u6790\u304c\u96e3\u3057\u3044\u5316\u5408\u7269\u3067\u3082\u3001\u5b89\u5b9a\u3057\u305f\u5206\u6790\u6027\u80fd\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:1.2rem\">TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\uff5c\u5e45\u5e83\u3044\u85ac\u7269\u30af\u30e9\u30b9\u3067\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u3092\u5b89\u5b9a\u5316<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:1rem\">\u305d\u3053\u3067Restek\u3067\u306f\u3001\u30b7\u30e9\u30ce\u30fc\u30eb\u306e\u5f71\u97ff\u3092\u6291\u3048\u308b\u6b21\u4e16\u4ee3\u306eTriMax\u4e0d\u6d3b\u6027\u51e6\u7406\u3092\u958b\u767a\u3057\u3001RMX\u30ab\u30e9\u30e0\u30b7\u30ea\u30fc\u30ba\u306b\u63a1\u7528\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u51e6\u7406\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u5168\u4f53\u306b\u308f\u305f\u3063\u3066\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u6709\u3059\u308b\u8868\u9762\u304c\u5f62\u6210\u3055\u308c\u3001\u3055\u307e\u3056\u307e\u306a\u85ac\u7269\u30af\u30e9\u30b9\u306b\u304a\u3044\u3066\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u6539\u5584\u304c\u5f97\u3089\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading\" style=\"font-size:1.2rem\">\u54c1\u8cea\u7ba1\u7406\uff5c\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u5316\u5408\u7269\u306b\u3088\u308b\u500b\u5225QC\u8a66\u9a13<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:1rem\">\u3055\u3089\u306b\u3001\u3059\u3079\u3066\u306eRMX\u30ab\u30e9\u30e0\u306f\u3001\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u5316\u5408\u7269\u3092\u7528\u3044\u305f\u500b\u5225\u306e\u54c1\u8cea\u7ba1\u7406\u8a66\u9a13\u3092\u5b9f\u65bd\u3057\u3066\u304a\u308a\u3001\u4e0d\u6d3b\u6027\u51e6\u7406\u306e\u6709\u52b9\u6027\u3068\u88fd\u9020\u30d7\u30ed\u30bb\u30b9\u304c\u53b3\u683c\u306b\u7ba1\u7406\u3055\u308c\u304a\u308a\u3001\u5206\u6790\u8005\u306f\u30ab\u30e9\u30e0\u6027\u80fd\u306b\u5bfe\u3057\u3066\u9ad8\u3044\u4fe1\u983c\u3092\u6301\u3063\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<br>\u3053\u308c\u306b\u3088\u308a\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u30015Sil\u7cfb\u3068\u3057\u3066\u306e\u6975\u6027\u3001\u512a\u308c\u305f\u8010\u71b1\u6027\u306b\u52a0\u3048\u3001\u6700\u5927\u9650\u306b\u9ad8\u3081\u3089\u308c\u305f\u8868\u9762\u4e0d\u6d3b\u6027\u5ea6\u3092\u517c\u306d\u5099\u3048\u3066\u304a\u308a\u3001GC-MS\u306b\u3088\u308b\u62bc\u53ce\u85ac\u7269\u306e\u540c\u5b9a\u7cbe\u5ea6\u5411\u4e0a\u306b\u9069\u3057\u305f\u30ab\u30e9\u30e0\u3068\u3044\u3048\u307e\u3059\uff08<strong>Figure 1<\/strong>\uff09\u3002\u7279\u306b\u3001\u5206\u6790\u304c\u56f0\u96e3\u306a\u5869\u57fa\u6027\u5316\u5408\u7269\uff08\u30c9\u30ad\u30b7\u30e9\u30df\u30f3\u3001\u30b7\u30af\u30ed\u30d9\u30f3\u30b6\u30d7\u30ea\u30f3\u3001\u30b3\u30c7\u30a4\u30f3\uff09\u304a\u3088\u3073\u5f31\u9178\u6027\u5316\u5408\u7269\uff08\u30a2\u30eb\u30d7\u30e9\u30be\u30e9\u30e0\uff09\u306e\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u60aa\u5316\u3092\u6291\u5236\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\uff08<strong>Figure 2<\/strong>\uff09\u3002<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:1rem\"><\/p>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image79652_9dc69d-9f:not(.kb-image-is-ratio-size) .kb-img, .kb-image79652_9dc69d-9f.kb-image-is-ratio-size{padding-right:100px;padding-left:100px;}.kb-image79652_9dc69d-9f .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image79652_9dc69d-9f\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-sales-JP\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"169\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-1024x169.jpg\" alt=\"\u304a\u554f\u3044\u5408\u308f\u305b\uff5cRestek\" class=\"kb-img wp-image-81960\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-1024x169.jpg 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-300x50.jpg 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-768x127.jpg 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-1536x254.jpg 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-SALES-JP-2048x339.jpg 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" style=\"font-size:1.2rem\">Results\uff5c\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3067\u898b\u308bRMX-5Sil MS\u306e\u52b9\u679c<\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-0bd16b36 wp-block-columns-is-layout-flex\" style=\"padding-right:100px;padding-left:100px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-theme-palette-7-background-color has-background wp-block-paragraph\" style=\"border-radius:10px;margin-top:0px;margin-bottom:0px;padding-right:5px;padding-left:5px;font-size:1.2rem\"><strong>Figure 1: <\/strong>RMX-5Sil MS\u30ab\u30e9\u30e0\u306b\u3088\u308b\u62bc\u53ce\u85ac\u7269\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30fc34\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u309221\u5206\u4ee5\u5185\u3067\u5206\u6790<br>\u2605PDF\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3044\u305f\u3060\u304f\u3068\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb\u3068\u5206\u6790\u6761\u4ef6\u3092\u4e00\u7dd2\u306b\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_cf1185.png\" alt=\"Acid, Base, and Neutral Drugs and Metabolites on RMX-5Sil MS\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_CF1185<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>17323<\/li><li>23303<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>RMX-library<\/li><li>drugs<\/li><li>drugs of abuse<\/li><li>forensic<\/li><li>seized drugs<\/li><li>toxicology<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_cf1185.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div><\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\" style=\"margin-top:0;margin-bottom:0\">\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb<\/p>\n\n\n<style>.kb-image79652_e2dcc9-c7:not(.kb-image-is-ratio-size) .kb-img, .kb-image79652_e2dcc9-c7.kb-image-is-ratio-size{padding-right:100px;padding-left:100px;}.kb-image79652_e2dcc9-c7 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image79652_e2dcc9-c7\"><figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"305\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/GC_CF1185-Peak-Table-1024x305.png\" alt=\"\u62bc\u53ce\u85ac\u7269, \u9055\u6cd5\u85ac\u7269, \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\" class=\"kb-img wp-image-82419\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/GC_CF1185-Peak-Table-1024x305.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/GC_CF1185-Peak-Table-300x89.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/GC_CF1185-Peak-Table-768x229.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/GC_CF1185-Peak-Table-1536x457.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/GC_CF1185-Peak-Table.png 1652w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure><\/div>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-0bd16b36 wp-block-columns-is-layout-flex\" style=\"padding-right:100px;padding-left:100px\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-theme-palette-7-background-color has-background wp-block-paragraph\" style=\"border-radius:10px;margin-top:0px;margin-bottom:0px;padding-right:5px;padding-left:5px;font-size:1.2rem\"><strong>Figure 2: <\/strong>\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u5099\u3048\u305fRMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u5206\u6790\u304c\u96e3\u3057\u3044\u9178\u6027\u30fb\u5869\u57fa\u6027\u85ac\u7269\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u6539\u5584<br>\u2605PDF\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3044\u305f\u3060\u304f\u3068\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb\u3068\u5206\u6790\u6761\u4ef6\u3092\u4e00\u7dd2\u306b\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-custom-chromatogram-article\"><div class=\"wp-block-custom-chromatogram-article\"><div class=\"chromatogram-image wide-image\"><img decoding=\"async\" src=\"https:\/\/ez.restek.com\/images\/cgram\/gc_cf1186.png\" alt=\"Comparison of Seized Drugs on RMX-5Sil MS and a Premium Competitor Column (Zooms)\" title=\"-\"><\/div><p class=\"article-id\" style=\"text-align:center\"> GC_CF1186<\/p><div class=\"chromatogram-related-skus\"><h4>Related SKUs<\/h4><ul><li>23303<\/li><li>17323<\/li><\/ul><\/div><div class=\"chromatogram-related-searches\"><h4>Related Searches<\/h4><ul><li>RMX-library<\/li><li>drugs<\/li><li>drugs of abuse<\/li><li>forensic<\/li><li>seized drugs<\/li><li>toxicology<\/li><\/ul><\/div><div class=\"chromatogram-pdf-link\"><a href=\"https:\/\/ez.restek.com\/images\/cgram\/gc_cf1186.pdf\" target=\"_blank\" rel=\"noopener noreferrer\"><svg xmlns=\"http:\/\/www.w3.org\/2000\/svg\" width=\"18\" height=\"18\" viewBox=\"0 0 18 18\"><g data-name=\"Group 2996\"><path data-name=\"Rectangle 1246\" d=\"M0 0h18v18H0z\" style=\"fill: none;\"><\/path><\/g><g data-name=\"Group 2997\"><path data-name=\"Path 729\" d=\"M13.412 11.4v2.017H5.345V11.4H4v2.017a1.349 1.349 0 0 0 1.345 1.345h8.068a1.349 1.349 0 0 0 1.345-1.345V11.4zm-.672-2.694-.948-.948-1.741 1.735V4H8.706v5.493L6.965 7.758l-.948.948 3.361 3.361z\" transform=\"translate(-.437 -.414)\" style=\"fill: rgb(13, 123, 196);\"><\/path><\/g><\/svg>Download PDF<\/a><\/div><\/div><\/div><\/div>\n<\/div>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">Tools\uff5cPro EZGC\u3067\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306b\u5408\u308f\u305b\u305f\u6761\u4ef6\u6700\u9069\u5316<\/h2>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image79652_6fb57b-2c.kb-image-is-ratio-size, .kb-image79652_6fb57b-2c .kb-image-is-ratio-size{max-width:700px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image79652_6fb57b-2c.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image79652_6fb57b-2c .kb-image-is-ratio-size{align-self:unset;}.kb-image79652_6fb57b-2c figure{max-width:700px;}.kb-image79652_6fb57b-2c .image-is-svg, .kb-image79652_6fb57b-2c .image-is-svg img{width:100%;}.kb-image79652_6fb57b-2c .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image79652_6fb57b-2c\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3445-ja\/ezgc-online-tools-japan\" class=\"kb-advanced-image-link\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"238\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-1024x238.png\" alt=\"GC\u5206\u6790\u6761\u4ef6, \u30e1\u30bd\u30c3\u30c9\u958b\u767a, \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\uff5cRestek\" class=\"kb-img wp-image-81949\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-1024x238.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-300x70.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4-768x179.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-EZGC-HTML-Block-Mock-Up\u30fcJP-4.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\">What Makes RMX Better ?\uff5cRMX\u30b7\u30ea\u30fc\u30ba\u306e\u8a2d\u8a08\u601d\u60f3<\/h2>\n\n\n\n<div style=\"height:40px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image79652_c49b17-d8.kb-image-is-ratio-size, .kb-image79652_c49b17-d8 .kb-image-is-ratio-size{max-width:678px;width:100%;}.wp-block-kadence-column > .kt-inside-inner-col > .kb-image79652_c49b17-d8.kb-image-is-ratio-size, .wp-block-kadence-column > .kt-inside-inner-col > .kb-image79652_c49b17-d8 .kb-image-is-ratio-size{align-self:unset;}.kb-image79652_c49b17-d8 figure{max-width:678px;}.kb-image79652_c49b17-d8 .image-is-svg, .kb-image79652_c49b17-d8 .image-is-svg img{width:100%;}.kb-image79652_c49b17-d8:not(.kb-image-is-ratio-size) .kb-img, .kb-image79652_c49b17-d8.kb-image-is-ratio-size{padding-right:10px;padding-left:10px;}.kb-image79652_c49b17-d8 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image79652_c49b17-d8\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/discover.restek.com\/ja\/rmx\/\" class=\"kb-advanced-image-link\"><img decoding=\"async\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-What-Makes-RMX-Better-WEB-JP_v3-5-scaled.png\" alt=\"GC\u30ab\u30e9\u30e0, \u4f4e\u5438\u7740, \u30c6\u30fc\u30ea\u30f3\u30b0, \u5869\u57fa\u6027\u5316\u5408\u7269, \u9178\u6027\u5316\u5408\u7269, 5\u7cfb\u30ab\u30e9\u30e0, 5%\u30d5\u30a7\u30cb\u30eb\u30ab\u30e9\u30e0\" class=\"kb-img\" title=\"-\"><\/a><\/figure><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n        <div class=\"cpb\">\n            <h3 class=\"cpb-heading\">\u95a2\u9023\u88fd\u54c1<\/h3>\n            <hr class=\"cpb-heading-underline\" \/>\n            <div class=\"cpb-list\">\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">                                \u30ab\u30bf\u30ed\u30b0No. 17323                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">RMX-5Sil MS GC\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u30ab\u30e9\u30e0, 30 m, 0.25 mm ID, 0.25 \u00b5m<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/17323\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">                                \u30ab\u30bf\u30ed\u30b0No. 23303                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Topaz, Single Taper Inlet Liner, 4.0 mm x 6.5 x 78.5, for Agilent GCs, w\/Quartz Wool, Premium Deactivation, 5-pk.<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/23303\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                                    <div class=\"cpb-item\">\n                        <div class=\"cpb-col cpb-col--left\">\n                            <a class=\"cpb-catalog\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">                                \u30ab\u30bf\u30ed\u30b0No. 28500                            <\/a>                        <\/div>\n                        <div class=\"cpb-col cpb-col--middle\">\n                            <div class=\"cpb-title\">Restek \u30ea\u30fc\u30af\u30c7\u30a3\u30c6\u30af\u30bf<\/div>\n                        <\/div>\n                        <div class=\"cpb-col cpb-col--right\">\n                                                            <a class=\"cpb-view-btn\" target=\"_blank\" rel=\"noopener noreferrer\" href=\"https:\/\/www.restek.com\/p\/28500\">\u88fd\u54c1\u60c5\u5831\u3092\u898b\u308b<\/a>\n                                                    <\/div>\n                    <\/div>\n                            <\/div>\n        <\/div>\n        \n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-image79652_ad5669-82:not(.kb-image-is-ratio-size) .kb-img, .kb-image79652_ad5669-82.kb-image-is-ratio-size{padding-right:100px;padding-left:100px;}.kb-image79652_ad5669-82 .kb-image-has-overlay:after{opacity:0.3;}<\/style>\n<div class=\"wp-block-kadence-image kb-image79652_ad5669-82\"><figure class=\"aligncenter size-large\"><a href=\"https:\/\/explore.restek.com\/RMX-contact-technical-service-JP\" class=\"kb-advanced-image-link\" target=\"_blank\" rel=\"noopener\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"170\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-1024x170.png\" alt=\"\u304a\u554f\u3044\u5408\u308f\u305b\uff5cRestek\" class=\"kb-img wp-image-82127\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-1024x170.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-300x50.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1-768x127.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/RMX-Graphic-Ad-Contact-us-HTML-Block-TECHNICAL-SERVICE-JA-1.png 1340w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/a><\/figure><\/div>\n\n\n\n<style>\n\/* JS\u304c\u4ed8\u3051\u308b\u30af\u30e9\u30b9\u3067\u975e\u8868\u793a\u306b\u3059\u308b *\/\n.rmx-hide-related {\n  display: none !important;\n}\n<\/style>\n\n<script>\n(function () {\n  function hideRelatedSections(root) {\n    if (!root) return;\n\n    \/\/ \u898b\u51fa\u3057\u5019\u88dc\uff08h2\/h3\u7b49\uff09\u3092\u5e83\u3081\u306b\u63a2\u7d22\n    const headings = root.querySelectorAll('h1,h2,h3,h4,h5,h6');\n\n    headings.forEach(h => {\n      const title = (h.textContent || '').trim().toLowerCase();\n\n      \/\/ \"Related SKUs\" \/ \"Related Searches\" \u3092\u5224\u5b9a\n      const isRelatedSkus = title === 'related skus' || title === 'related sku';\n      const isRelatedSearches = title === 'related searches' || title === 'related search';\n\n      if (isRelatedSkus || isRelatedSearches) {\n        \/\/ \u898b\u51fa\u3057\u81ea\u8eab\u3092\u96a0\u3059\n        h.classList.add('rmx-hide-related');\n\n        \/\/ \u76f4\u5f8c\u306e\u30ea\u30b9\u30c8\uff08ul\/ol\u7b49\uff09\u3084\u3001\u95a2\u9023\u30b3\u30f3\u30c6\u30ca\u3092\u96a0\u3059\n        \/\/ \u307e\u305a nextElementSibling \u3092\u96a0\u3059\uff08\u591a\u304f\u306e\u30c6\u30f3\u30d7\u30ec\u304c\u3053\u308c\u3067OK\uff09\n        let next = h.nextElementSibling;\n        if (next) next.classList.add('rmx-hide-related');\n\n        \/\/ \u5ff5\u306e\u305f\u3081\u3001\u6b21\u304c\u30b3\u30f3\u30c6\u30ca\u3067\u305d\u306e\u4e2d\u306b\u30ea\u30b9\u30c8\u304c\u3042\u308b\u5834\u5408\u3082\u96a0\u3059\n        \/\/ \uff08next \u304c div \u306e\u3053\u3068\u3082\u3042\u308b\u305f\u3081\uff09\n        if (next && next.querySelectorAll) {\n          const lists = next.querySelectorAll('ul,ol');\n          lists.forEach(li => li.classList.add('rmx-hide-related'));\n        }\n      }\n    });\n  }\n\n  function run() {\n    \/\/ Chromatogram Block\u306e\u5916\u307e\u3067\u5dfb\u304d\u8fbc\u307e\u306a\u3044\u3088\u3046\u3001\u53ef\u80fd\u306a\u3089\u30d6\u30ed\u30c3\u30af\u7bc4\u56f2\u3092\u7d5e\u308b\n    \/\/ 1) \u307e\u305a \"Chromatogram Block\" \u306e\u8fd1\u508d\u3092\u63a2\u3059\uff08\u30af\u30e9\u30b9\u304c\u3042\u308c\u3070\u305d\u3053\u306b\u7f6e\u63db\u63a8\u5968\uff09\n    const candidate =\n      document.querySelector('.chromatogram-block') ||\n      document.querySelector('[data-block-name*=\"chromatogram\" i]') ||\n      document;\n\n    hideRelatedSections(candidate);\n  }\n\n  \/\/ \u521d\u56de\n  if (document.readyState === 'loading') {\n    document.addEventListener('DOMContentLoaded', run);\n  } else {\n    run();\n  }\n\n  \/\/ \u30d7\u30ec\u30d3\u30e5\u30fc\u304c\u5f8c\u304b\u3089\u63cf\u753b\u3055\u308c\u308b\u30b1\u30fc\u30b9\u306b\u5099\u3048\u3066\u3001\u5c11\u3057\u3060\u3051\u518d\u5b9f\u884c\n  setTimeout(run, 500);\n  setTimeout(run, 1500);\n})();\n<\/script>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Key Higlights Introduction\uff5c\u62bc\u53ce\u85ac\u7269\u5206\u6790\u306b\u304a\u3051\u308bGC\u30ab\u30e9\u30e0\u9078\u629e\u306e\u91cd\u8981\u6027 \u62bc\u53ce\u85ac\u7269\u3092\u6271\u3046\u5206\u6790\u6a5f\u95a2\u3067\u306f\u3001\u672a\u77e5\u306e\u8a66\u6599\u304c\u9055\u6cd5\u85ac\u7269\u3067\u3042\u308b\u304b\u3092\u5224\u5b9a\u3059\u308b\u305f\u3081\u306b\u3001GC-MS\u5206\u6790\u304c\u65e5\u5e38\u7684\u306b\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u969b\u3001GC\u30ab\u30e9\u30e0\u306e\u9078\u629e\u306f\u3001\u30c7\u30fc\u30bf\u54c1\u8cea\u304a\u3088\u3073\u5206\u6790\u6cd5\u306e\u4fe1\u983c\u6027\u3092\u5de6\u53f3\u3059\u308b\u91cd\u8981\u306a\u8981\u7d20\u3068\u306a\u308a\u307e\u3059\u3002\u85ac\u7269\u5206\u6790\u3067\u306f\u3001\u975e\u5e38\u306b\u591a\u69d8\u306a\u5316\u5b66\u69cb\u9020\u3092\u3082\u3064\u5316\u5408\u7269\u3092\u540c\u5b9a\u3059\u308b\u5fc5\u8981\u304c\u3042\u308b\u305f\u3081\u3001\u300c5 \u7cfb\u300d\u30ab\u30e9\u30e0\u306b\u4ee3\u8868\u3055\u308c\u308b\u5fae\u6975\u6027\u30ab\u30e9\u30e0\u304c\u4e00\u822c\u7684\u306b\u4f7f\u7528\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u30b7\u30e9\u30ea\u30ec\u30f3\u30dd\u30ea\u30de\u30fc\u3092\u7528\u3044\u305f\u300c5Sil \u7cfb\u300d\u56fa\u5b9a\u76f8\u306f\u3001\u5f93\u6765\u306e5 \u7cfb\u30ab\u30e9\u30e0\u3092\u69cb\u9020\u7684\u306b\u6539\u826f\u3057\u305f\u3082\u306e\u3067\u3042\u308a\u3001\u3088\u308a\u9ad8\u3044\u8010\u71b1\u6027\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u8cea\u91cf\u5206\u6790\u8a08\u3068\u7d44\u307f\u5408\u308f\u305b\u305f\u969b\u306b\u3082\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u9577\u671f\u9593\u7dad\u6301\u3067\u304d\u308b\u3053\u3068\u304b\u3089\u3001\u85ac\u7269\u5206\u6790\u7528\u9014\u306b\u9069\u3057\u305f\u9078\u629e\u80a2\u3068\u3044\u3048\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u5e45\u5e83\u3044\u85ac\u7269\u3092\u4e00\u6589\u306b\u5206\u6790\u3059\u308b\u5834\u5408\u3001\u5316\u5408\u7269\u30af\u30e9\u30b9\u306b\u3088\u3063\u3066\u6319\u52d5\u306b\u5dee\u304c\u751f\u3058\u3001\u30d4\u30fc\u30af\u30c6\u30fc\u30ea\u30f3\u30b0\u3084\u4fdd\u6301\u6642\u9593\u306e\u305a\u308c\u306b\u3088\u3063\u3066\u3001\u85ac\u7269\u540c\u5b9a\u304c\u8907\u96d1\u306b\u306a\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u3059\u3002 \u306a\u305c\u30d4\u30fc\u30af\u5f62\u72b6\u304c\u5d29\u308c\u308b\u306e\u304b\uff5c\u30b7\u30e9\u30ce\u30fc\u30eb\u76f8\u4e92\u4f5c\u7528\u3068\u5438\u7740 \u9178\u6027\u5316\u5408\u7269\u306e\u4e00\u90e8\u3001\u4f8b\u3048\u3070\u30d0\u30eb\u30d3\u30c4\u30fc\u30eb\u9178\u7cfb\u5316\u5408\u7269\u3067\u306f\u3001\u5f31\u9178\u6027\u306eN\u2013H\u57fa\u3068 GC\u30ab\u30e9\u30e0\u8868\u9762\u306b\u5b58\u5728\u3059\u308b\u30b7\u30e9\u30ce\u30fc\u30eb\u3068\u306e\u9593\u306b\u767a\u751f\u3059\u308b\u5f37\u3044\u76f8\u4e92\u4f5c\u7528\u306b\u3088\u308a\u3001\u56fa\u5b9a\u76f8\u3078\u306e\u5206\u914d\u304c\u4e0d\u5747\u4e00\u306b\u306a\u308a\u3084\u3059\u3044\u3053\u3068\u304c\u77e5\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u307e\u305f\u3001\u30a2\u30df\u30f3\u985e\u306e\u3088\u3046\u306a\u5869\u57fa\u6027\u5b98\u80fd\u57fa\u3092\u3082\u3064\u85ac\u7269\u3067\u306f\u3001\u30ab\u30e9\u30e0\u8868\u9762\u3068\u306e\u6c34\u7d20\u7d50\u5408\u306b\u3088\u308a\u3001\u56fa\u5b9a\u76f8\u304b\u3089\u6eb6\u51fa\u304c\u9045\u308c\u305f\u308a\u3001\u5834\u5408\u306b\u3088\u3063\u3066\u306f\u5316\u5408\u7269\u304c\u8868\u9762\u306b\u5b8c\u5168\u306b\u5438\u7740\u3055\u308c\u3066\u3057\u307e\u3046\u3053\u3068\u3082\u3042\u308a\u307e\u3059\u3002\u3057\u304b\u3057\u3001GC\u30ab\u30e9\u30e0\u8868\u9762\u306b\u5b58\u5728\u3059\u308b\u30b7\u30e9\u30ce\u30fc\u30eb\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u3092\u6291\u5236\u3067\u304d\u308c\u3070\u3001\u5b98\u80fd\u57fa\u306e\u7570\u306a\u308b\u5e45\u5e83\u3044\u85ac\u7269\u306b\u304a\u3044\u3066\u3001\u7279\u306b\u5206\u6790\u304c\u96e3\u3057\u3044\u5316\u5408\u7269\u3067\u3082\u3001\u5b89\u5b9a\u3057\u305f\u5206\u6790\u6027\u80fd\u304c\u5f97\u3089\u308c\u307e\u3059\u3002 TriMax\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\uff5c\u5e45\u5e83\u3044\u85ac\u7269\u30af\u30e9\u30b9\u3067\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u3092\u5b89\u5b9a\u5316 \u305d\u3053\u3067Restek\u3067\u306f\u3001\u30b7\u30e9\u30ce\u30fc\u30eb\u306e\u5f71\u97ff\u3092\u6291\u3048\u308b\u6b21\u4e16\u4ee3\u306eTriMax\u4e0d\u6d3b\u6027\u51e6\u7406\u3092\u958b\u767a\u3057\u3001RMX\u30ab\u30e9\u30e0\u30b7\u30ea\u30fc\u30ba\u306b\u63a1\u7528\u3057\u307e\u3057\u305f\u3002\u3053\u306e\u51e6\u7406\u306b\u3088\u308a\u3001\u30ab\u30e9\u30e0\u5168\u4f53\u306b\u308f\u305f\u3063\u3066\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u6709\u3059\u308b\u8868\u9762\u304c\u5f62\u6210\u3055\u308c\u3001\u3055\u307e\u3056\u307e\u306a\u85ac\u7269\u30af\u30e9\u30b9\u306b\u304a\u3044\u3066\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u6539\u5584\u304c\u5f97\u3089\u308c\u307e\u3059\u3002 \u54c1\u8cea\u7ba1\u7406\uff5c\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u5316\u5408\u7269\u306b\u3088\u308b\u500b\u5225QC\u8a66\u9a13 \u3055\u3089\u306b\u3001\u3059\u3079\u3066\u306eRMX\u30ab\u30e9\u30e0\u306f\u3001\u9178\u6027\u30fb\u5869\u57fa\u6027\u30fb\u4e2d\u6027\u5316\u5408\u7269\u3092\u7528\u3044\u305f\u500b\u5225\u306e\u54c1\u8cea\u7ba1\u7406\u8a66\u9a13\u3092\u5b9f\u65bd\u3057\u3066\u304a\u308a\u3001\u4e0d\u6d3b\u6027\u51e6\u7406\u306e\u6709\u52b9\u6027\u3068\u88fd\u9020\u30d7\u30ed\u30bb\u30b9\u304c\u53b3\u683c\u306b\u7ba1\u7406\u3055\u308c\u304a\u308a\u3001\u5206\u6790\u8005\u306f\u30ab\u30e9\u30e0\u6027\u80fd\u306b\u5bfe\u3057\u3066\u9ad8\u3044\u4fe1\u983c\u3092\u6301\u3063\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001RMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u30015Sil\u7cfb\u3068\u3057\u3066\u306e\u6975\u6027\u3001\u512a\u308c\u305f\u8010\u71b1\u6027\u306b\u52a0\u3048\u3001\u6700\u5927\u9650\u306b\u9ad8\u3081\u3089\u308c\u305f\u8868\u9762\u4e0d\u6d3b\u6027\u5ea6\u3092\u517c\u306d\u5099\u3048\u3066\u304a\u308a\u3001GC-MS\u306b\u3088\u308b\u62bc\u53ce\u85ac\u7269\u306e\u540c\u5b9a\u7cbe\u5ea6\u5411\u4e0a\u306b\u9069\u3057\u305f\u30ab\u30e9\u30e0\u3068\u3044\u3048\u307e\u3059\uff08Figure 1\uff09\u3002\u7279\u306b\u3001\u5206\u6790\u304c\u56f0\u96e3\u306a\u5869\u57fa\u6027\u5316\u5408\u7269\uff08\u30c9\u30ad\u30b7\u30e9\u30df\u30f3\u3001\u30b7\u30af\u30ed\u30d9\u30f3\u30b6\u30d7\u30ea\u30f3\u3001\u30b3\u30c7\u30a4\u30f3\uff09\u304a\u3088\u3073\u5f31\u9178\u6027\u5316\u5408\u7269\uff08\u30a2\u30eb\u30d7\u30e9\u30be\u30e9\u30e0\uff09\u306e\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u60aa\u5316\u3092\u6291\u5236\u3057\u3066\u3044\u308b\u3053\u3068\u304c\u5206\u304b\u308a\u307e\u3059\uff08Figure 2\uff09\u3002 Results\uff5c\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u3067\u898b\u308bRMX-5Sil MS\u306e\u52b9\u679c Figure 1: RMX-5Sil MS\u30ab\u30e9\u30e0\u306b\u3088\u308b\u62bc\u53ce\u85ac\u7269\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30fc34\u7a2e\u985e\u306e\u4e71\u7528\u85ac\u7269\u309221\u5206\u4ee5\u5185\u3067\u5206\u6790\u2605PDF\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3044\u305f\u3060\u304f\u3068\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb\u3068\u5206\u6790\u6761\u4ef6\u3092\u4e00\u7dd2\u306b\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002 \u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb Figure 2: \u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u5099\u3048\u305fRMX-5Sil MS\u30ab\u30e9\u30e0\u306f\u3001\u5206\u6790\u304c\u96e3\u3057\u3044\u9178\u6027\u30fb\u5869\u57fa\u6027\u85ac\u7269\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u6539\u5584\u2605PDF\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u3044\u305f\u3060\u304f\u3068\u30d4\u30fc\u30af\u30c6\u30fc\u30d6\u30eb\u3068\u5206\u6790\u6761\u4ef6\u3092\u4e00\u7dd2\u306b\u3054\u89a7\u3044\u305f\u3060\u3051\u307e\u3059\u3002 Tools\uff5cPro EZGC\u3067\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u306b\u5408\u308f\u305b\u305f\u6761\u4ef6\u6700\u9069\u5316 What Makes RMX Better ?\uff5cRMX\u30b7\u30ea\u30fc\u30ba\u306e\u8a2d\u8a08\u601d\u60f3<\/p>\n","protected":false},"author":26,"featured_media":61164,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":"","_ppma_block_editor_authors":""},"categories":[789],"tags":[2745],"industries-application":[2277,2276,2266,2269],"post-badge":[2752],"resource-type":[],"product-library":[2564,2552],"resource-technique":[2340,2345],"ppma_author":[446,454,2657,452],"class_list":["post-79652","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles-ja","tag-rmx-resources","industries-application-forensics-toxicology-ja","industries-application-forensics-ja","industries-application-clinical-ja","industries-application-clinical-toxicology-ja","post-badge-new","product-library-gc-columns-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja","resource-technique-mass-spectrometry-ms-ja"],"acf":[],"taxonomy_info":{"category":[{"value":789,"label":"\u6280\u8853\u8cc7\u6599"}],"post_tag":[{"value":2745,"label":"RMX \u8d44\u6e90\u5e93"}],"industries-application":[{"value":2277,"label":"\u6cd5\u4e2d\u6bd2\u5b66"},{"value":2276,"label":"\u6cd5\u533b\u5b66"},{"value":2266,"label":"\u81e8\u5e8a"},{"value":2269,"label":"\u81e8\u5e8a\u6bd2\u6027\u5b66"}],"post-badge":[{"value":2752,"label":"New"}],"product-library":[{"value":2564,"label":"GC \u30ab\u30e9\u30e0"},{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"},{"value":2345,"label":"\u8cea\u91cf\u5206\u6790 (MS)"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/feature-CFFA4918-1024x568.jpg",1024,568,true],"author_info":{"display_name":"Corby Hilliard","author_link":"https:\/\/discover.restek.com\/ja\/author\/corby-hilliard\/"},"comment_info":0,"category_info":[{"term_id":789,"name":"\u6280\u8853\u8cc7\u6599","slug":"articles-ja","term_group":0,"term_taxonomy_id":789,"taxonomy":"category","description":"","parent":0,"count":510,"filter":"raw","cat_ID":789,"category_count":510,"category_description":"","cat_name":"\u6280\u8853\u8cc7\u6599","category_nicename":"articles-ja","category_parent":0}],"tag_info":[{"term_id":2745,"name":"RMX \u8d44\u6e90\u5e93","slug":"rmx-resources","term_group":0,"term_taxonomy_id":2745,"taxonomy":"post_tag","description":"\u7acb\u5373\u63a2\u7d22 RMX \u8d44\u6e90\u5e93","parent":0,"count":23,"filter":"raw"}],"authors":[{"term_id":446,"user_id":26,"is_guest":0,"slug":"corby-hilliard","display_name":"Corby Hilliard","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-Hilliard-Corby.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-Hilliard-Corby.jpg"},"author_category":"1","first_name":"Corby","last_name":"Hilliard","user_url":"https:\/\/www.linkedin.com\/in\/corby-hilliard-69b1ba275\/","job_title":"Advanced Scientist, GC Applied","description":"Corby Hilliard started his Restek career in the Quality Assurance department where he spent his first seven years as a QA analyst and worked his way up to a senior QA analyst. He then moved on to the Innovations department in 2009 as a GC Solutions Advanced Scientist. His experience is predominately in gas chromatography (GC) using various detectors and mass spectrometry as well as troubleshooting and method development. His primary work for Restek is generating product application data, using new and existing products in food safety, petrochemical, environmental, and the GC accessories line. He also is involved with quality and R&amp;D as well as new product development."},{"term_id":454,"user_id":34,"is_guest":0,"slug":"erica-pack-phd","display_name":"Erica Pack, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-pack-erica.jpg"},"author_category":"1","first_name":"Erica","last_name":"Pack","user_url":"https:\/\/www.linkedin.com\/in\/ericapack\/","job_title":"Senior Scientist, GC Applied","description":"Erica is an interdisciplinary GC applications and technologies scientist at Restek. She obtained her bachelor's degree in forensic biology from The Pennsylvania State University, and her doctorate from Virginia Tech in plant pathology, physiology, and weed science. Since joining Restek in 2021, she has worked with a wide variety of GC columns, including fused silica, MXT, PLOT, and packed columns as well as accessories, such as liners, valves, and methanizers."},{"term_id":2657,"user_id":70,"is_guest":0,"slug":"ramkumar-dhandapani-phd","display_name":"Ramkumar Dhandapani, PhD","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Dhandapani_Ramkumar_Profile.jpg"},"author_category":"1","first_name":"Ramkumar","last_name":"Dhandapani","user_url":"https:\/\/www.linkedin.com\/in\/dr-ramkumar-dhandapani-b9012424\/?skipRedirect=true&enhance=null","job_title":"Director of Product Management","description":"Dr. Ramkumar Dhandapani\u00a0is a seasoned analytical chemist with over\u00a023 years of experience\u00a0in the chromatography industry and a Ph.D. in analytical chemistry. During his career, he has specialized in method development, validation, and the troubleshooting of chromatography methods. He has developed numerous regulatory-compliant methods across diverse sectors, including\u00a0environmental analysis, food quality and safety, pharmaceutical, fuels, and chemical industries. Currently, Dr. Dhandapani is the Director of Product Management at Restek, he is keen on innovation in chromatography and scaling breakthrough innovations\u00a0to market as commercial products."},{"term_id":452,"user_id":32,"is_guest":0,"slug":"colton-myers","display_name":"Colton Myers","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/people-myers-colton.jpg"},"author_category":"1","first_name":"Colton","last_name":"Myers","user_url":"https:\/\/www.linkedin.com\/in\/myerscolton\/","job_title":"Product Manager - New Product Development","description":"Colton Myers is a Product Manager for GC columns at Restek Corporation with over 10 years of experience in research and development. He specializes in driving new GC column technologies from concept to market, combining deep technical expertise with a strong focus on innovation and commercialization. Colton holds a BS in chemistry from Juniata College and a Master of Management in Corporate Innovation and Entrepreneurship from Penn State University."}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/79652","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/26"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=79652"}],"version-history":[{"count":101,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/79652\/revisions"}],"predecessor-version":[{"id":95105,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/79652\/revisions\/95105"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/61164"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=79652"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=79652"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=79652"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=79652"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=79652"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=79652"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=79652"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=79652"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=79652"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}