{"id":88320,"date":"2026-02-26T06:42:02","date_gmt":"2026-02-26T06:42:02","guid":{"rendered":"https:\/\/discover.restek.com\/?p=88320"},"modified":"2026-05-29T04:07:29","modified_gmt":"2026-05-29T04:07:29","slug":"kiwami-2026-wax-column-introduction","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kw202601\/kiwami-2026-wax-column-introduction","title":{"rendered":"\u6975\u6027\u5316\u5408\u7269\u306eGC\u5206\u6790\u3067WAX\u30ab\u30e9\u30e0\u304c\u6709\u52b9\u306a\u7406\u7531\uff5c\u5206\u96e2\u306e\u8003\u3048\u65b9\u3068\u7528\u9014\u5225WAX\u56fa\u5b9a\u76f8\u306e\u6574\u7406"},"content":{"rendered":"\n<p class=\"has-text-align-right has-theme-palette-1-color has-text-color has-link-color has-small-font-size wp-elements-08ab486f7d015185ad4e24dadbc490b9\">\u203b\u6c17\u306b\u306a\u3063\u305f\u30ad\u30fc\u30ef\u30fc\u30c9\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u3055\u3089\u306b\u6df1\u5800\u3057\u305f\u8a18\u4e8b<strong><em><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kw202602\/kiwami-2026-wax-column-expert\" target=\"_blank\" rel=\"noreferrer noopener\">\uff08\u89e3\u8aac\u7de8\uff09<\/a><\/em><\/strong>\u3082\u305c\u3072\u3054\u89a7\u304f\u3060\u3055\u3044\uff01<\/p>\n\n\n<style>.kadence-column88320_d3e163-c4 > .kt-inside-inner-col,.kadence-column88320_d3e163-c4 > .kt-inside-inner-col:before{border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-right-radius:0px;border-bottom-left-radius:0px;}.kadence-column88320_d3e163-c4 > .kt-inside-inner-col{column-gap:var(--global-kb-gap-sm, 1rem);}.kadence-column88320_d3e163-c4 > .kt-inside-inner-col{flex-direction:column;}.kadence-column88320_d3e163-c4 > .kt-inside-inner-col > .aligncenter{width:100%;}.kadence-column88320_d3e163-c4 > .kt-inside-inner-col:before{opacity:0.3;}.kadence-column88320_d3e163-c4{position:relative;}@media all and (max-width: 1024px){.kadence-column88320_d3e163-c4 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}@media all and (max-width: 767px){.kadence-column88320_d3e163-c4 > .kt-inside-inner-col{flex-direction:column;justify-content:center;}}<\/style>\n<div class=\"wp-block-kadence-column kadence-column88320_d3e163-c4\"><div class=\"kt-inside-inner-col\"><style>.wp-block-kadence-iconlist.kt-svg-icon-list-items88320_8ab024-2a:not(.this-stops-third-party-issues){margin-top:0px;margin-bottom:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items88320_8ab024-2a ul.kt-svg-icon-list:not(.this-prevents-issues):not(.this-stops-third-party-issues):not(.tijsloc){margin-top:0px;margin-right:0px;margin-bottom:var(--global-kb-spacing-sm, 1.5rem);margin-left:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items88320_8ab024-2a ul.kt-svg-icon-list{grid-row-gap:5px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items88320_8ab024-2a ul.kt-svg-icon-list .kt-svg-icon-list-item-wrap .kt-svg-icon-list-single{margin-right:10px;}.kt-svg-icon-list-items88320_8ab024-2a ul.kt-svg-icon-list .kt-svg-icon-list-item-wrap, .kt-svg-icon-list-items88320_8ab024-2a ul.kt-svg-icon-list .kt-svg-icon-list-item-wrap a{font-size:var(--global-kb-font-size-sm, 0.9rem);line-height:1px;}.kt-svg-icon-list-items88320_8ab024-2a ul.kt-svg-icon-list .kt-svg-icon-list-level-0 .kt-svg-icon-list-single svg{font-size:20px;}<\/style>\n<div class=\"wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items88320_8ab024-2a kt-svg-icon-list-columns-1 alignnone\"><ul class=\"kt-svg-icon-list\"><style>.kt-svg-icon-list-item-88320_1b5999-8e .kt-svg-icon-list-single{font-size:30px !important;color:#ec0606 !important;}.kt-svg-icon-list-item-88320_1b5999-8e .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-size:var(--global-kb-font-size-md, 1.25rem);font-weight:100;font-style:normal;color:#0b73df;background:var(--global-palette1, #3182CE);-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-88320_1b5999-8e\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fas_splotch kt-svg-icon-list-single\"><svg viewBox=\"0 0 512 512\"  fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M472.29 195.89l-67.06-22.95c-19.28-6.6-33.54-20.92-38.14-38.3L351.1 74.19c-11.58-43.77-76.57-57.13-109.98-22.62l-46.14 47.67c-13.26 13.71-33.54 20.93-54.2 19.31l-71.88-5.62c-52.05-4.07-86.93 44.88-59.03 82.83l38.54 52.42c11.08 15.07 12.82 33.86 4.64 50.24L24.62 355.4c-20.59 41.25 22.84 84.87 73.49 73.81l69.96-15.28c20.11-4.39 41.45 0 57.07 11.73l54.32 40.83c39.32 29.56 101.04 7.57 104.45-37.22l4.7-61.86c1.35-17.79 12.8-33.86 30.63-42.99l62-31.74c44.88-22.96 39.59-80.17-8.95-96.79z\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\"><strong>\u3053\u306e\u8a18\u4e8b\u306b\u306f\u3053\u3093\u306a\u3053\u3068\u304c\u66f8\u3044\u3066\u3042\u308a\u307e\u3059\uff01<\/strong><\/span><\/li>\n<\/ul><\/div>\n<\/div><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"571\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Head\u90e8\u5206\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-1024x571.png\" alt=\"\" class=\"wp-image-93444\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Head\u90e8\u5206\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-1024x571.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Head\u90e8\u5206\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-300x167.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Head\u90e8\u5206\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/Head\u90e8\u5206\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-1536x857.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/Head\u90e8\u5206\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-2048x1143.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p>\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u306b\u304a\u3044\u3066\u3001\u30a2\u30eb\u30b3\u30fc\u30eb\u3001\u6709\u6a5f\u9178\u3001\u30d5\u30a7\u30ce\u30fc\u30eb\u985e\u306a\u3069\u306e\u9ad8\u6975\u6027\u5316\u5408\u7269\u306e\u5206\u96e2\u306f\u3001\u4e00\u822c\u7684\u306a\u30b7\u30ed\u30ad\u30b5\u30f3\u7cfb\u30ab\u30e9\u30e0\u3067\u306f\u4fdd\u6301\u4e0d\u8db3\u3084\u8457\u3057\u3044\u30d4\u30fc\u30af\u5f62\u72b6\u306e\u60aa\u5316\u304c\u751f\u3058\u3084\u3059\u3044\u50be\u5411\u306b\u3042\u308a\u307e\u3059\u3002\u3053\u3046\u3057\u305f\u6975\u6027\u5316\u5408\u7269\u306eGC\u5206\u6790\u306b\u6709\u52b9\u306a\u306e\u304c\u3001<strong>\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08PEG\uff09<\/strong>\u3092\u56fa\u5b9a\u76f8\u3068\u3059\u308b\u6975\u6027GC\u30ab\u30e9\u30e0\u3001\u3044\u308f\u3086\u308b<strong>WAX\u30ab\u30e9\u30e0<\/strong>\u3067\u3059\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001WAX\u30ab\u30e9\u30e0\u306e\u5206\u96e2\u539f\u7406\u3068\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u3092\u6574\u7406\u3057\u3001\u7528\u9014\u5225\u56fa\u5b9a\u76f8\u306e\u9078\u629e\u30dd\u30a4\u30f3\u30c8\u306a\u3069\u3092\u521d\u5fc3\u8005\u3067\u3082\u308f\u304b\u308a\u3084\u3059\u304f\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group has-theme-palette-8-background-color has-background is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-theme-palette-1-color has-text-color has-link-color has-medium-font-size wp-elements-595241f5c21206d88967f5ca09aad0b7\" id=\"mokuji\"><strong>\u25ce\u76ee\u6b21\u25ce<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><a href=\"#mokuji1\" data-type=\"internal\" data-id=\"#mokuji1\">\u306a\u305c\u6975\u6027\u5316\u5408\u7269\u306eGC\u5206\u96e2\u306f\u96e3\u3057\u3044\u306e\u304b<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji2\" data-type=\"internal\" data-id=\"#mokuji2\">WAX\u30ab\u30e9\u30e0\u306e\u57fa\u672c\u7684\u306a\u4fdd\u6301\u306e\u8003\u3048\u65b9\uff1aPEG\u306e\u5206\u5b50\u69cb\u9020\u3068\u5206\u96e2\u306e\u3057\u304f\u307f<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji3\" data-type=\"internal\" data-id=\"#mokuji3\">\u76ee\u7684\u5225\u30fb\u30ab\u30e9\u30e0\u306e\u9078\u3073\u65b9\uff1a\u6975\u6027\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3051\u308b\u7528\u9014\u5225GC WAX\u56fa\u5b9a\u76f8<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji4\" data-type=\"internal\" data-id=\"#mokuji4\">\u5805\u7262\u6027\uff1a\u6c34\u6ce8\u5165\u30fbGC-MS\u5206\u6790\u306b\u5bfe\u5fdc\u3059\u308bWAX\u30ab\u30e9\u30e0\u306e\u6027\u80fd<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji5\" data-type=\"internal\" data-id=\"#mokuji5\">\u3055\u3044\u3054\u306b\uff1a\u6975\u6027\u5316\u5408\u7269\u306eGC\u5206\u6790\u3092\u5b89\u5b9a\u3055\u305b\u308b\u305f\u3081\u306e\u30d7\u30e9\u30b9\u30ef\u30f3\u30dd\u30a4\u30f3\u30c8<\/a><\/li>\n<\/ol>\n<\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji1\" style=\"font-size:38px;line-height:1.4\">1. <strong>\u306a\u305c\u6975\u6027\u5316\u5408\u7269\u306eGC\u5206\u96e2\u306f\u96e3\u3057\u3044\u306e\u304b<\/strong><\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-62ebb68a6bb29ee6b22eab2feeca1f2a\" style=\"font-size:18px\"><strong>\u30b7\u30ed\u30ad\u30b5\u30f3\u7cfb\u30ab\u30e9\u30e0\u306e\u9650\u754c<\/strong><\/h3>\n\n\n\n<p style=\"font-size:18px\">GC\u3067\u6700\u3082\u666e\u53ca\u3057\u3066\u3044\u308b\u306e\u306f\u7121\u6975\u6027\u56fa\u5b9a\u76f8\u3067\u3042\u308b<strong>\u30dd\u30ea\u30b8\u30e1\u30c1\u30eb\u30b7\u30ed\u30ad\u30b5\u30f3\uff081\u7cfb\uff09<\/strong>\u3084<strong>5\uff05\u30d5\u30a7\u30cb\u30eb\u7cfb\uff085\u7cfb\uff09<\/strong>\u3067\u3059\u304c\u3001\u3053\u308c\u3089\u306f\u4e3b\u306b\u30ed\u30f3\u30c9\u30f3\u5206\u6563\u529b\uff08\u30d5\u30a1\u30f3\u30c7\u30eb\u30ef\u30fc\u30eb\u30b9\u529b\u306e\u4e00\u7a2e\uff09\u306b\u57fa\u3065\u3044\u3066\u5206\u96e2\u3092\u884c\u3044\u307e\u3059\u3002\u3057\u304b\u3057\u3001\u6c34\u7d20\u7d50\u5408\u30c9\u30ca\u30fc\u3092\u6301\u3064\u4f4e\u5206\u5b50\u6975\u6027\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u306f\u4fdd\u6301\u304c\u4e0d\u5341\u5206\u3067\u3042\u308a\u3001\u30d4\u30fc\u30af\u5f62\u72b6\u3082\u60aa\u5316\u3057\u3084\u3059\u3044\u3068\u3044\u3046\u8ab2\u984c\u304c\u3042\u308a\u307e\u3059\uff08\u56fa\u5b9a\u76f8\u3054\u3068\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u9055\u3044\u306b\u3064\u3044\u3066\u306f<em><strong><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kw202602\/kiwami-2026-wax-column-expert#mokuji22\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089<\/a><\/strong><\/em>\u306b\u8a73\u7d30\u3092\u8a18\u8f09\u3057\u3066\u3044\u307e\u3059\uff09\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-d453b6e798a0fdb48d565a0f81981017\" style=\"font-size:18px\"><strong>\u5206\u914d\u3068\u306f\u7570\u306a\u308b\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0<\/strong><\/h3>\n\n\n\n<p style=\"font-size:18px\"><strong><em>WAX\u30ab\u30e9\u30e0\u306b\u7528\u3044\u3089\u308c\u308b\u56fa\u5b9a\u76f8<\/em><\/strong>\u306f\u3001\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff08PEG\uff09\u3092\u30d9\u30fc\u30b9\u3068\u3057\u305f\u6975\u6027\u30dd\u30ea\u30de\u30fc\u3067\u3059\u3002PEG\u306f\u3001\u305d\u306e\u4e3b\u9396\u306b\u5f37\u3044\u53cc\u6975\u5b50\u30e2\u30fc\u30e1\u30f3\u30c8\u3092\u6301\u3064\u30a8\u30fc\u30c6\u30eb\u9178\u7d20\u3092\u542b\u3093\u3067\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30bf\u30fc\u30b2\u30c3\u30c8\u5316\u5408\u7269\u3068\u306e\u9593\u306b<strong>\u5f37\u529b\u306a\u76f8\u4e92\u4f5c\u7528<\/strong>\uff08\u6b21\u9805\u3067\u8a73\u8aac\uff09\u3092\u751f\u307f\u51fa\u3057\u3001\u975e\u6975\u6027\u30ab\u30e9\u30e0\u3067\u306f\u4e0d\u53ef\u80fd\u306a\u9078\u629e\u7684\u5206\u96e2\u3092\u53ef\u80fd\u306b\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<figure class=\"wp-block-gallery aligncenter has-nested-images columns-default is-cropped wp-block-gallery-1 is-layout-flex wp-block-gallery-is-layout-flex\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" data-id=\"88392\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u56fa\u5b9a\u76f8\u306f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb-2.png\" alt=\"\" class=\"wp-image-88392\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u56fa\u5b9a\u76f8\u306f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb-2.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u56fa\u5b9a\u76f8\u306f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb-2-300x169.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u56fa\u5b9a\u76f8\u306f\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb-2-768x432.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" data-id=\"88398\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30dd\u30ea\u30de\u30fc\u306e\u7d14\u5ea6-2.png\" alt=\"\" class=\"wp-image-88398\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30dd\u30ea\u30de\u30fc\u306e\u7d14\u5ea6-2.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30dd\u30ea\u30de\u30fc\u306e\u7d14\u5ea6-2-300x169.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30dd\u30ea\u30de\u30fc\u306e\u7d14\u5ea6-2-768x432.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/figure>\n<\/div><\/div>\n\n\n\n<p class=\"has-small-font-size\"><a href=\"#mokuji\" data-type=\"internal\" data-id=\"#mokuji\"><strong>\u261d\u76ee\u6b21\u306b\u623b\u308b<\/strong><\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji2\" style=\"font-size:38px;line-height:1.4\"><strong>2.WAX\u30ab\u30e9\u30e0\u306e\u57fa\u672c\u7684\u306a\u4fdd\u6301\u306e\u8003\u3048\u65b9\uff1aPEG\u306e\u5206\u5b50\u69cb\u9020\u3068\u5206\u96e2\u306e\u3057\u304f\u307f<\/strong><\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-e7610bd5273ba7298c840974446cf454\" style=\"font-size:18px\"><strong>PEG\u56fa\u5b9a\u76f8\u3068\u306f\uff1f<\/strong><\/h3>\n\n\n\n<p style=\"font-size:18px\">PEG\u56fa\u5b9a\u76f8\u306f\u30a8\u30c1\u30ec\u30f3\u30aa\u30ad\u30b7\u30c9\uff08\u2013CH\u2082\u2013CH\u2082\u2013O\u2013\uff09\u306e\u7e70\u308a\u8fd4\u3057\u69cb\u9020\u304b\u3089\u306a\u308b\u7dda\u72b6\u9ad8\u5206\u5b50\u3092\u57fa\u76e4\u3068\u3057\u305f\u6975\u6027\u56fa\u5b9a\u76f8\u3067\u3059\u3002\u4e3b\u9396\u4e2d\u306b\u898f\u5247\u7684\u306b\u914d\u7f6e\u3055\u308c\u305f\u30a8\u30fc\u30c6\u30eb\u9178\u7d20\u306f\u5c40\u6240\u7684\u306b\u5f37\u3044\u53cc\u6975\u5b50\u7279\u6027\u3092\u6301\u3061\u3001\u6c34\u7d20\u7d50\u5408\u30a2\u30af\u30bb\u30d7\u30bf\u30fc\u3068\u3057\u3066\u6a5f\u80fd\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-a2df84ecbd83222190ade3a009bbfa78\" style=\"font-size:18px\"><strong>PEG\u56fa\u5b9a\u76f8\u306b\u304a\u3051\u308b\u5206\u96e2\u306e\u3057\u304f\u307f\uff1a\u6c34\u7d20\u7d50\u5408\u30fb\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\u306e\u201d\u6982\u5ff5\u201c<\/strong><\/h3>\n\n\n\n<p style=\"font-size:18px\">WAX\u30ab\u30e9\u30e0\u306e\u5206\u96e2\u306f\u3001\u5358\u306a\u308b\u300c\u6975\u6027\u306e\u9ad8\u3055\u300d\u3060\u3051\u3067\u6c7a\u307e\u308b\u3082\u306e\u3067\u306f\u3042\u308a\u307e\u305b\u3093\u3002PEG\u56fa\u5b9a\u76f8\u3092\u4e00\u7a2e\u306e\u6975\u6027\u6eb6\u5a92\u76f8\u3068\u3057\u3066\u6349\u3048\u305f\u3068\u304d\u3001\u5206\u6790\u5bfe\u8c61\u5316\u5408\u7269\u304c\u305d\u306e\u76f8\u306b\u3069\u306e\u7a0b\u5ea6\u6eb6\u3051\u8fbc\u307f\u3001\u51fa\u5165\u308a\u3059\u308b\u304b\u3068\u3044\u3046\u5206\u914d\u6319\u52d5\u306e\u7d50\u679c\u3068\u3057\u3066\u4fdd\u6301\u304c\u6c7a\u307e\u308a\u307e\u3059\u3002\u305d\u306e\u969b\u3001\u4e3b\u306b\u4ee5\u4e0b\u306e3\u3064\u306e\u5206\u5b50\u9593\u76f8\u4e92\u4f5c\u7528\u304c\u8907\u5408\u7684\u306b\u50cd\u3044\u3066\u3044\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:66.66%\">\n<ul class=\"wp-block-list\">\n<li class=\"has-medium-font-size\" style=\"margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40)\">\u6c34\u7d20\u7d50\u5408\uff08Hydrogen bonding\uff09\uff1a PEG\u4e2d\u306e\u30a8\u30fc\u30c6\u30eb\u9178\u7d20\u304c\u30d7\u30ed\u30c8\u30f3\u4f9b\u4e0e\u6027\u5b98\u80fd\u57fa\uff08\u2013OH, \u2013COOH\u306a\u3069\uff09\u3068\u6c34\u7d20\u7d50\u5408\u3092\u5f62\u6210\u3002<\/li>\n\n\n\n<li class=\"has-medium-font-size\" style=\"margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40)\">\u53cc\u6975\u5b50\u2013\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\uff1a \u6975\u6027\u5b98\u80fd\u57fa\uff08\u2013C=O, \u2013NO\u2082\u306a\u3069\uff09\u3092\u6709\u3059\u308b\u5206\u6790\u5bfe\u8c61\u3068\u3001PEG\u5074\u306e\u9178\u7d20\u539f\u5b50\u3068\u306e\u9593\u3067\u9759\u96fb\u7684\u306b\u5b89\u5b9a\u5316\u3059\u308b\u76f8\u4e92\u4f5c\u7528\u3002<\/li>\n\n\n\n<li class=\"has-medium-font-size\" style=\"margin-top:var(--wp--preset--spacing--40);margin-bottom:var(--wp--preset--spacing--40)\">\u6eb6\u5a92\u548c\u69d8\u5206\u914d\uff08Solvation-based partitioning\uff09\uff1a \u6975\u6027\u56fa\u5b9a\u76f8\u4e2d\u3078\u306e\u9078\u629e\u7684\u6eb6\u89e3\uff08partitioning\uff09\u306b\u3088\u308a\u3001\u56fa\u5b9a\u76f8\u2013\u79fb\u52d5\u76f8\u9593\u306e\u5206\u914d\u4fc2\u6570\u304c\u5897\u5927\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:33.33%\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"571\" height=\"1024\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u5206\u96e2\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\uff08\u4fee\u6b63\u6e08\uff09-571x1024.png\" alt=\"\" class=\"wp-image-89797\" style=\"aspect-ratio:0.5586142398243402\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u5206\u96e2\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\uff08\u4fee\u6b63\u6e08\uff09-571x1024.png 571w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u5206\u96e2\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\uff08\u4fee\u6b63\u6e08\uff09-167x300.png 167w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u5206\u96e2\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\uff08\u4fee\u6b63\u6e08\uff09-768x1376.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u5206\u96e2\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\uff08\u4fee\u6b63\u6e08\uff09-857x1536.png 857w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u5206\u96e2\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\uff08\u4fee\u6b63\u6e08\uff09-1143x2048.png 1143w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u5206\u96e2\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\uff08\u4fee\u6b63\u6e08\uff09-scaled.png 1429w\" sizes=\"auto, (max-width: 571px) 100vw, 571px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-c8222eedd6401c1d17e66b0e865981cb\" style=\"font-size:18px\"><strong>\u6e29\u5ea6\u3068\u4fdd\u6301\u306e\u95a2\u4fc2<\/strong><\/h3>\n\n\n\n<p>GC\u5206\u6790\u306b\u304a\u3044\u3066<strong><em><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kw202602\/kiwami-2026-wax-column-expert#mokuji24\" target=\"_blank\" rel=\"noreferrer noopener\">\u300c\u6e29\u5ea6\u300d\u306f\u3001\u5206\u96e2\u3092\u5de6\u53f3\u3059\u308b\u6700\u5927\u306e\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc<\/a><\/em><\/strong>\u3067\u3059\u3002\u7279\u306b\u3001WAX\u30ab\u30e9\u30e0\u306e\u3088\u3046\u306a\u6975\u6027\u56fa\u5b9a\u76f8\u3067\u306f\u3001\u305d\u306e\u50be\u5411\u304c\u3055\u3089\u306b\u9855\u8457\u306b\u306a\u308a\u307e\u3059\u3002\u3053\u306e\u7406\u7531\u3092\u7406\u89e3\u3059\u308b\u306b\u306f\u3001\u307e\u305aGC\u306e\u4fdd\u6301\u4fc2\u6570 k&#8217;\u304c\u3069\u306e\u3088\u3046\u306b\u6e29\u5ea6\u306b\u4f9d\u5b58\u3057\u3066\u3044\u308b\u304b\u3092\u898b\u3066\u307f\u307e\u3057\u3087\u3046\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"185\" height=\"65\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/image.gif\" alt=\"\" class=\"wp-image-88442\" style=\"aspect-ratio:2.8463102656608723;width:259px;height:auto\" title=\"-\"><\/figure>\n<\/div>\n\n\n<p>\u3053\u306e\u5f0f\u306fGC\u306e\u4fdd\u6301\u4fc2\u6570 k&#8217; \u306f\u3001\u5438\u7740\u30fb\u5206\u914d\u306b\u95a2\u308f\u308b\u30a8\u30f3\u30bf\u30eb\u30d4\u30fc\u5909\u5316\u0394<em>H<\/em>\u306b\u652f\u914d\u3055\u308c\u3066\u3044\u308b\u3053\u3068\u3092\u793a\u3057\u3066\u3044\u307e\u3059\u3002PEG\u306f\u5206\u6790\u7a2e\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u5f37\u3044\u305f\u3081\u0394<em>H<\/em>\u304c\u5927\u304d\u304f\u306a\u308b\u50be\u5411\u304c\u3042\u308a\u3001\u300c\u6e29\u5ea6\u306e\u308f\u305a\u304b\u306a\u5909\u5316\u3067\u4fdd\u6301\u6642\u9593\u304c\u5927\u304d\u304f\u52d5\u304f\u300d\u3068\u3044\u3046\u7279\u6027\u3092\u6301\u3061\u307e\u3059\u3002\u3053\u306e\u611f\u5ea6\u306e\u9ad8\u3055\u3092\u5229\u7528\u3057\u3001\u7cbe\u5bc6\u306a\u6e29\u5ea6\u5236\u5fa1\u3092\u884c\u3046\u3053\u3068\u3067\u3001\u9078\u629e\u6027\uff08\u96a3\u63a5\u3057\u305f\u6210\u5206\u306e\u5206\u96e2\u5ea6\uff09\u3092\u5411\u4e0a\u3055\u305b\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002\u3057\u305f\u304c\u3063\u3066\u3001\u6e29\u5ea6\u6761\u4ef6\u306f\u300c\u4fdd\u6301\u6642\u9593\u3092\u5408\u308f\u305b\u308b\u305f\u3081\u306e\u64cd\u4f5c\u300d\u3067\u306f\u306a\u304f\u3001\u300c\u9078\u629e\u6027\u3092\u8a2d\u8a08\u3059\u308b\u305f\u3081\u306e\u64cd\u4f5c\u300d\u3068\u3057\u3066\u6271\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\uff08\u4fdd\u6301\u6319\u52d5\u306e\u691c\u8a0e\u306b\u6e29\u5ea6\u5236\u5fa1\u304c\u91cd\u8981\u306a\u7406\u7531\u306f<strong><em><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kw202602\/kiwami-2026-wax-column-expert#mokuji23\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089<\/a><\/em><\/strong>\u304b\u3089\u3054\u78ba\u8a8d\u304f\u3060\u3055\u3044\uff01\uff09\u3002<\/p>\n\n\n\n<p class=\"has-small-font-size\"><a href=\"#mokuji\" data-type=\"internal\" data-id=\"#mokuji\"><strong>\u261d\u76ee\u6b21\u306b\u623b\u308b<\/strong><\/a><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji3\" style=\"font-size:38px;line-height:1.4\">3. <strong><strong>\u76ee\u7684\u5225\u30fb\u30ab\u30e9\u30e0\u306e\u9078\u3073\u65b9\uff1a\u6975\u6027\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3051\u308b\u7528\u9014\u5225GC WAX\u56fa\u5b9a\u76f8<\/strong><\/strong><\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p><strong><em><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kw202602\/kiwami-2026-wax-column-expert#mokuji31\" target=\"_blank\" rel=\"noreferrer noopener\">Carbowax\u304b\u3089\u5316\u5b66\u7d50\u5408\u578b\u3078\u9032\u5316\u3057\u305fWAX\u30ab\u30e9\u30e0<\/a><\/em><\/strong>\u3002\u30b5\u30f3\u30d7\u30eb\u306e\u5316\u5b66\u7684\u6027\u8cea\uff08\u9178\u30fb\u5869\u57fa\uff09\u3084\u6c34\u5206\u542b\u6709\u91cf\u306b\u5fdc\u3058\u3066\u6700\u9069\u5316\u3055\u308c\u305f\u300c\u5c02\u7528\u76f8\u300d\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u304c<strong><em><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kw202602\/kiwami-2026-wax-column-expert#mokuji32\" target=\"_blank\" rel=\"noreferrer noopener\">\u5e45\u5e83\u3044\u5206\u91ce\u306b\u304a\u3051\u308b\u5206\u6790<\/a><\/em><\/strong>\u6210\u529f\u306e\u9375\u3068\u306a\u308a\u307e\u3059\u3002<br>\u53c2\u7167\u60c5\u5831\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/wax-chromatogram-library\" target=\"_blank\" rel=\"noreferrer noopener\">WAX\u30ab\u30e9\u30e0\u306e\u5206\u6790\u4e8b\u4f8b\u96c6<\/a>\u3001<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnot3472b-ja\/guides-and-cross-references-japan\" target=\"_blank\" rel=\"noreferrer noopener\">GC\u30ab\u30e9\u30e0\u306e\u76f8\u4e92\u53c2\u7167\u8868<\/a>\u3001<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/GNAR1724-JA\/japan-guide-to-gc-column-selection-and-optimizing-separations\" target=\"_blank\" rel=\"noreferrer noopener\">GC\u30ab\u30e9\u30e0\u9078\u629e\u3068\u5206\u96e2\u306e\u6700\u9069\u5316\u30ac\u30a4\u30c9<\/a><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n<style>.kb-table-container88320_c7641a-6b{overflow-x:auto;}.kb-table88320_c7641a-6b td:nth-of-type(1), .kb-table88320_c7641a-6b th:nth-of-type(1){width:25%;}.kb-table88320_c7641a-6b td:nth-of-type(2), .kb-table88320_c7641a-6b th:nth-of-type(2){width:50%;}.kb-table88320_c7641a-6b td:nth-of-type(3), .kb-table88320_c7641a-6b th:nth-of-type(3){width:25%;}.kb-table88320_c7641a-6b{table-layout:fixed;width:100%;}.kb-table-container .kb-table88320_c7641a-6b th{padding-top:var(--global-kb-spacing-xxs, 0.5rem);padding-right:var(--global-kb-spacing-xxs, 0.5rem);padding-bottom:var(--global-kb-spacing-xxs, 0.5rem);padding-left:var(--global-kb-spacing-xxs, 0.5rem);text-align:center;}.kb-table-container .kb-table88320_c7641a-6b caption{text-align:center;}.kb-table-container .kb-table88320_c7641a-6b td{padding-top:var(--global-kb-spacing-xxs, 0.5rem);padding-right:var(--global-kb-spacing-xxs, 0.5rem);padding-bottom:var(--global-kb-spacing-xxs, 0.5rem);padding-left:var(--global-kb-spacing-xxs, 0.5rem);text-align:left;}<\/style><div class=\"kb-table-container kb-table-container88320_c7641a-6b wp-block-kadence-table\"><table class=\"kb-table kb-table88320_c7641a-6b\">\n<style>.kb-table-container .kb-table tr.kb-table-row88320_551a26-b6{background-color:var(--global-palette6, #718096);}<\/style><tr class=\"kb-table-row kb-table-row88320_551a26-b6\">\n<th class=\"kb-table-data kb-table-data88320_9ded85-68\">\n\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-c755570b89d526bf7a761f3cca0216b1\">\u30ab\u30e9\u30e0\u30bf\u30a4\u30d7<\/p>\n\n<\/th>\n\n<th class=\"kb-table-data kb-table-data88320_917000-c6\">\n\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-a74afc4e1aa2e7aa82cab14a8979f5bd\">\u7279\u9577<\/p>\n\n<\/th>\n\n<th class=\"kb-table-data kb-table-data88320_53f962-b9\">\n\n<p class=\"has-theme-palette-9-color has-text-color has-link-color wp-elements-9f7541d61674604762834ef8b38f88ce\">\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8\u3078\u306e\u30ea\u30f3\u30af<\/p>\n\n<\/th>\n<\/tr>\n\n<style>.kb-table-container .kb-table tr.kb-table-row88320_c89e8b-09{background-color:var(--global-palette7, #EDF2F7);}<\/style><tr class=\"kb-table-row kb-table-row88320_c89e8b-09\">\n<td class=\"kb-table-data kb-table-data88320_5d08cf-d6\">\n\n<p><strong><em>\u6c4e\u7528WAX<\/em>\u203b\u63a8\u5968<\/strong><\/p>\n\n\n\n<p><strong>\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10623\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax<\/a>\uff09<\/strong><\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_eaf341-8c\">\n\n<p>\u88fd\u9020\u5de5\u7a0b\u306e\u5168\u30b9\u30c6\u30c3\u30d7\u3092\u6700\u9069\u5316\u3057\u305f\u6b21\u4e16\u4ee3WAX\u3067\u3059\u3002\u6975\u3081\u3066\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9\u3068\u9ad8\u3044\u518d\u73fe\u6027\u3092\u8a87\u308a\u3001\u82b3\u9999\u65cf\u3001\u6eb6\u5a92\u3001\u9999\u6599\u306a\u3069\u306e\u5206\u6790\u306b\u304a\u3051\u308b\u30d5\u30a1\u30fc\u30b9\u30c8\u30c1\u30e7\u30a4\u30b9\u3067\u3059\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_35ccb4-d5\">\n\n<p><strong><em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Stabilwax.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">Stabiliwax\u4f7f\u7528<\/a><\/em><\/strong><\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row88320_00c054-ec\">\n<td class=\"kb-table-data kb-table-data88320_12f401-39\">\n\n<p><strong><em>\u6c4e\u7528WAX<\/em><\/strong><\/p>\n\n\n\n<p><strong>\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/12423\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-Wax<\/a>\uff09<\/strong><\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_cbdcda-3c\">\n\n<p>\u7279\u6b8a\u306a\u67b6\u6a4b\u5264\u3092\u63a1\u7528\u3057\u3066\u304a\u308a\u3001\u6c34\u6ce8\u5165\u306b\u5bfe\u3059\u308b\u8010\u4e45\u6027\u304c\u975e\u5e38\u306b\u9ad8\u3044\u306e\u304c\u7279\u5fb4\u3067\u3059\u3002\u30a2\u30eb\u30c7\u30d2\u30c9\u3084\u4e00\u90e8\u306e\u9999\u6c17\u6210\u5206\u3067\u512a\u308c\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u793a\u3057\u307e\u3059\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_6b9648-13\">\n\n<p><strong><em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/RtxWax.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-Wax\u4f7f\u7528<\/a><\/em><\/strong><\/p>\n\n<\/td>\n<\/tr>\n\n<style>.kb-table-container .kb-table tr.kb-table-row88320_5f749c-05{background-color:var(--global-palette7, #EDF2F7);}<\/style><tr class=\"kb-table-row kb-table-row88320_5f749c-05\">\n<td class=\"kb-table-data kb-table-data88320_ba4563-84\">\n\n<p><strong><em>\u9178\u6027\u5316\u5408\u7269\u7528<\/em><\/strong><\/p>\n\n\n\n<p><strong>\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/11023\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax-DA<\/a>\uff09<\/strong><\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_9b8657-05\">\n\n<p>\u9178\u6027\u5b98\u80fd\u57fa\u3092\u5c0e\u5165\uff08\u30a8\u30b9\u30c6\u30eb\u5316\u51e6\u7406\uff09\u3057\u3066\u304a\u308a\u3001\u6709\u6a5f\u9178\u3084\u8102\u80aa\u9178\u3092\u8a98\u5c0e\u4f53\u5316\u306a\u3057\u3067\u5206\u6790\u3067\u304d\u307e\u3059\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_319d90-b4\">\n\n<p><strong><em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/StabilwaxDA.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax-DA\u4f7f\u7528<\/a><\/em><\/strong><\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row88320_2def0d-a1\">\n<td class=\"kb-table-data kb-table-data88320_877b1a-01\">\n\n<p><strong><em>\u5869\u57fa\u6027\u5316\u5408\u7269\u7528<\/em><\/strong><\/p>\n\n\n\n<p><strong>\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10823\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax-DB<\/a>\uff09<\/strong><\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_620864-0e\">\n\n<p>\u5185\u58c1\u3092\u30a2\u30eb\u30ab\u30ea\u51e6\u7406\u3059\u308b\u3053\u3068\u3067\u3001\u30a2\u30df\u30f3\u306a\u3069\u306e\u5438\u7740\u3092\u6291\u5236\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u7169\u96d1\u306a\u30ab\u30e9\u30e0\u30d7\u30e9\u30a4\u30df\u30f3\u30b0\uff08\u5438\u7740\u70b9\u306e\u6d88\u5931\u64cd\u4f5c\uff09\u304c\u4e0d\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_e65492-bf\">\n\n<p><strong><em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/StabilwaxDB.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax-DB\u4f7f\u7528<\/a><\/em><\/strong><\/p>\n\n<\/td>\n<\/tr>\n\n<style>.kb-table-container .kb-table tr.kb-table-row88320_0e70e8-6d{background-color:var(--global-palette7, #EDF2F7);}<\/style><tr class=\"kb-table-row kb-table-row88320_0e70e8-6d\">\n<td class=\"kb-table-data kb-table-data88320_786417-49\">\n\n<p><strong><em>GC-MS\u5c02\u7528<\/em><\/strong><\/p>\n\n\n\n<p><strong>\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10673\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax-MS<\/a>\uff09<\/strong><\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_bb32df-77\">\n\n<p>WAX\u7cfb\u306e\u4e2d\u3067\u6700\u3082\u4f4e\u30d6\u30ea\u30fc\u30c9\u306a\u4ed5\u69d8\u3067\u3059\u3002MS\u5206\u6790\u3067\u7279\u5fb4\u7684\u306a m\/z 45 \u306e\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\u30ce\u30a4\u30ba\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u540c\u5b9a\u7cbe\u5ea6\u3092\u9ad8\u3081\u307e\u3059\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_2f94a6-15\">\n\n<p><strong><em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/StabilwaxMS.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax-MS\u4f7f\u7528<\/a><\/em><\/strong><\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row88320_d31dc5-fb\">\n<td class=\"kb-table-data kb-table-data88320_3d0106-18\">\n\n<p><strong><em>\u8102\u80aa\u9178\u30e1\u30c1\u30eb\u30a8\u30b9\u30c6\u30eb\u7528<\/em><\/strong><\/p>\n\n\n\n<p><strong>\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/12497\" target=\"_blank\" rel=\"noreferrer noopener\">FAMEWAX<\/a>\uff09<\/strong><\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_668981-c3\">\n\n<p>FAMEWAX\u306f\u8102\u80aa\u9178\u30e1\u30c1\u30eb\u30a8\u30b9\u30c6\u30eb\u5c02\u7528\u306b\u8a2d\u8a08\u3055\u308c\u305f\u9ad8\u6975\u6027WAX\u30ab\u30e9\u30e0\u3067\u3059\u3002\u70ad\u7d20\u6570\u3084\u4e0d\u98fd\u548c\u5ea6\u3001\u30b7\u30b9\uff0f\u30c8\u30e9\u30f3\u30b9\u7570\u6027\u4f53\u306e\u5206\u96e2\u306b\u512a\u308c\u3001\u7279\u306bEPA\u30fbDHA\u306a\u3069\u591a\u4fa1\u4e0d\u98fd\u548c\u8102\u80aa\u9178\u306e\u5206\u6790\u3067\u9ad8\u3044\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3059\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data88320_3fd99b-37\">\n\n<p><strong><em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/FAMEWAX.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">FAMEWAX\u4f7f\u7528<\/a><\/em><\/strong><\/p>\n\n<\/td>\n<\/tr>\n<\/table><\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"571\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u9078\u629e\u30ac\u30a4\u30c9\uff08\u4fee\u6b63\u6e08\uff09-1024x571.png\" alt=\"\" class=\"wp-image-89790\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u9078\u629e\u30ac\u30a4\u30c9\uff08\u4fee\u6b63\u6e08\uff09-1024x571.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u9078\u629e\u30ac\u30a4\u30c9\uff08\u4fee\u6b63\u6e08\uff09-300x167.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u9078\u629e\u30ac\u30a4\u30c9\uff08\u4fee\u6b63\u6e08\uff09-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u9078\u629e\u30ac\u30a4\u30c9\uff08\u4fee\u6b63\u6e08\uff09-1536x857.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/WAX\u30ab\u30e9\u30e0\u9078\u629e\u30ac\u30a4\u30c9\uff08\u4fee\u6b63\u6e08\uff09-2048x1143.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-small-font-size\"><a href=\"#mokuji\" data-type=\"internal\" data-id=\"#mokuji\"><strong>\u261d\u76ee\u6b21\u306b\u623b\u308b<\/strong><\/a><\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji4\" style=\"font-size:38px;line-height:1.4\"><strong>4. \u5805\u7262\u6027\uff1a\u6c34\u6ce8\u5165\u30fbGC-MS\u5206\u6790\u306b\u5bfe\u5fdc\u3059\u308bWAX\u30ab\u30e9\u30e0\u306e\u6027\u80fd<\/strong><\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>WAX\u30ab\u30e9\u30e0\u3067\u306f\u3001\u6c34\u6eb6\u6db2\u306e\u76f4\u63a5\u6ce8\u5165\u3068\u3044\u3063\u305f\u904e\u9177\u306a\u6761\u4ef6\u4e0b\u3067\u306e\u8010\u4e45\u6027\u3068\u3001\u8cea\u91cf\u5206\u6790\uff08MS\uff09\u306b\u9069\u3057\u305f\u4f4e\u30d6\u30ea\u30fc\u30c9\u7279\u6027\u304c\u91cd\u8981\u306a\u8a2d\u8a08\u8981\u7d20\u3068\u306a\u3063\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-aa3a89da5667df0abef6658bf185b084\" style=\"font-size:18px\"><strong>\u6c34\u6ce8\u5165\u306b\u5bfe\u3059\u308b\u9ad8\u3044\u8010\u4e45\u6027\uff08Rtx-Wax\uff09<\/strong><\/h3>\n\n\n\n<p style=\"font-size:18px\">\u74b0\u5883\u5206\u6790\u3084\u5316\u5b66\u5206\u6790\u306b\u304a\u3044\u3066\u983b\u7e41\u306b\u884c\u308f\u308c\u308b\u6c34\u6eb6\u6db2\u306e\u76f4\u63a5\u6ce8\u5165\u306f\u3001\u56fa\u5b9a\u76f8\u3084\u6ce8\u5165\u53e3\u30e9\u30a4\u30ca\u30fc\u306b\u5927\u304d\u306a\u8ca0\u62c5\u3092\u304b\u3051\u307e\u3059\u3002\u3057\u304b\u3057\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/12423\" target=\"_blank\" rel=\"noreferrer noopener\">Rtx-Wax<\/a>\u306f\u6c34\u6eb6\u5a92\u3068\u306e\u89aa\u548c\u6027\u304c\u9ad8\u3044PEG\u56fa\u5b9a\u76f8\u3092\u9ad8\u5ea6\u306b\u5b89\u5b9a\u5316\u3055\u305b\u3066\u304a\u308a\u3001600\u56de\u4ee5\u4e0a\u306e\u6c34\u6ce8\u5165\u5f8c\u3082\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3084\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306e\u5bfe\u79f0\u306a\u30d4\u30fc\u30af\u5f62\u72b6\uff08\u5bfe\u79f0\u60270.9\u4ee5\u4e0a\uff09\u3092\u7dad\u6301\u3057\u307e\u3059\u3002\u3053\u306e\u8010\u4e45\u6027\u306f\u3001\u7e70\u308a\u8fd4\u3057\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3082\u4fe1\u983c\u6027\u306e\u9ad8\u3044\u691c\u91cf\u7dda\u306e\u76f4\u7dda\u6027\u3092\u4fdd\u8a3c\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-c65948925a7a509332670f7ea0fa4b08\" style=\"font-size:18px\"><strong>MS\u5206\u6790\u306b\u304a\u3051\u308b\u611f\u5ea6\u5411\u4e0a\uff08Stabilwax-MS\uff09<\/strong><\/h3>\n\n\n\n<p style=\"font-size:18px\">\u8cea\u91cf\u5206\u6790\u8a08\uff08MS\uff09\u3092\u691c\u51fa\u5668\u3068\u3057\u3066\u4f7f\u7528\u3059\u308b\u5834\u5408\u3001\u30ab\u30e9\u30e0\u30d6\u30ea\u30fc\u30c9\u306b\u3088\u308b\u30d0\u30c3\u30af\u30b0\u30e9\u30a6\u30f3\u30c9\uff08m\/z 45\u7b49\uff09\u306e\u6291\u5236\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10673\" target=\"_blank\" rel=\"noreferrer noopener\">Stabilwax-MS<\/a>\u306e\u3088\u3046\u306aRxi\u30c6\u30af\u30ce\u30ed\u30b8\u30fc\u3092\u9069\u7528\u3057\u305f\u4f4e\u30d6\u30ea\u30fc\u30c9\u30ab\u30e9\u30e0\u306f\u3001\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u4ed8\u8fd1\u3067\u3082\u6975\u3081\u3066\u4f4e\u3044\u30d6\u30ea\u30fc\u30c9\u3092\u793a\u3057\u3001\u4f4e\u6fc3\u5ea6\u6210\u5206\u306e\u691c\u51fa\u9650\u754c\uff08LOD\uff09\u306e\u6539\u5584\u3068\u540c\u5b9a\u7cbe\u5ea6\u306e\u5411\u4e0a\u306b\u5bc4\u4e0e\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u6c34\u6ce8\u5165\u306b\u5bfe\u3059\u308b\u8010\u4e45\u6027.png\" alt=\"\" class=\"wp-image-88459\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u6c34\u6ce8\u5165\u306b\u5bfe\u3059\u308b\u8010\u4e45\u6027.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u6c34\u6ce8\u5165\u306b\u5bfe\u3059\u308b\u8010\u4e45\u6027-300x169.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u6c34\u6ce8\u5165\u306b\u5bfe\u3059\u308b\u8010\u4e45\u6027-768x432.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u4ed8\u8fd1\u306b\u304a\u3051\u308b\u8010\u4e45\u6027.png\" alt=\"\" class=\"wp-image-88465\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u4ed8\u8fd1\u306b\u304a\u3051\u308b\u8010\u4e45\u6027.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u4ed8\u8fd1\u306b\u304a\u3051\u308b\u8010\u4e45\u6027-300x169.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u4ed8\u8fd1\u306b\u304a\u3051\u308b\u8010\u4e45\u6027-768x432.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\"><a href=\"#mokuji\" data-type=\"internal\" data-id=\"#mokuji\"><strong>\u261d\u76ee\u6b21\u306b\u623b\u308b<\/strong><\/a><\/p>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji5\" style=\"font-size:38px;line-height:1.4\">5. <strong><strong>\u3055\u3044\u3054\u306b\uff1a\u6975\u6027\u5316\u5408\u7269\u306eGC\u5206\u6790\u3092\u5b89\u5b9a\u3055\u305b\u308b\u305f\u3081\u306e\u30d7\u30e9\u30b9\u30ef\u30f3\u30dd\u30a4\u30f3\u30c8<\/strong><\/strong><\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>WAX\u30ab\u30e9\u30e0\u306f\u3001\u305d\u306e\u30e6\u30cb\u30fc\u30af\u306a\u300c\u5438\u7740\u30fb\u5206\u914d\u300d\u306e\u529b\u3092\u6d3b\u304b\u3057\u3001\u9999\u6599\u306e\u30d7\u30ed\u30d5\u30a1\u30a4\u30ea\u30f3\u30b0\u304b\u3089\u98df\u54c1\u4e2d\u306e\u8102\u80aa\u9178\u5206\u6790\u3001\u5de5\u696d\u7528\u6eb6\u5a92\u306e\u54c1\u8cea\u7ba1\u7406\u307e\u3067\u3001GC\u5206\u6790\u306b\u4e0d\u53ef\u6b20\u306a\u5f79\u5272\u3092\u62c5\u3044\u7d9a\u3051\u3066\u3044\u307e\u3059\u3002<br>\u30d4\u30fc\u30af\u306e\u30c6\u30fc\u30ea\u30f3\u30b0\u3092\u9632\u3050\u306b\u306f\u3001\u30ab\u30e9\u30e0\u3060\u3051\u3067\u306a\u304f\u3001\u9069\u5207\u306b\u4e0d\u6d3b\u6027\u5316\u3055\u308c\u305f<a href=\"https:\/\/discover.restek.com\/ja\/articles-ja\/gnbr2638-ja\/japanese-topaz-gc-inlet-liners\" target=\"_blank\" rel=\"noreferrer noopener\">Topaz\u30e9\u30a4\u30ca\u30fc<\/a>\u3084<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10623-124\" target=\"_blank\" rel=\"noreferrer noopener\">\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\uff08Integra-Guard\uff08\u4e00\u4f53\u578b\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\uff09<\/a>\u542b\u3080\uff09\u3001\u3068<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/10293\" target=\"_blank\" rel=\"noreferrer noopener\">\u30ea\u30c6\u30f3\u30b7\u30e7\u30f3\u30ae\u30e3\u30c3\u30d7<\/a>\u306e\u4f7f\u7528\u304c\u91cd\u8981\u3067\u3059\u3002\u3053\u308c\u3089\u306e\u30cf\u30fc\u30c9\u30a6\u30a7\u30a2\u306e\u6700\u9069\u5316\u306b\u52a0\u3048\u3001\u5206\u6790\u6761\u4ef6\u3092\u77ac\u6642\u306b\u30b7\u30df\u30e5\u30ec\u30fc\u30c8\u3067\u304d\u308b<a href=\"https:\/\/ez.restek.com\/proezgc\/ja\" target=\"_blank\" rel=\"noreferrer noopener\">Pro <em>EZ<\/em>GC Chromatogram Modeler<\/a> \u3092\u6d3b\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u6975\u6027\u5316\u5408\u7269\u306e\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u3092\u7c21\u5358\u306b\u884c\u3048\u307e\u3059\u3002\u305c\u3072\u3001\u3053\u3046\u3057\u305f\u30c4\u30fc\u30eb\u3082\u6d3b\u7528\u3057\u306a\u304c\u3089\u3001WAX\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u3092\u691c\u8a0e\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"has-theme-palette-2-color has-text-color has-link-color wp-elements-ce173bb42769775fa6b4e92bf2bb44eb\"><strong>\u672c\u7a3f\u3067\u89e6\u308c\u305f\u5185\u5bb9\u306b\u52a0\u3048\u3066\u3001\u30e9\u30a4\u30ca\u30fc\u3001\u30ac\u30fc\u30c9\u30ab\u30e9\u30e0\u3001\u30ea\u30c6\u30f3\u30b7\u30e7\u30f3\u30ae\u30e3\u30c3\u30d7\u306e\u8a2d\u5b9a\u306a\u3069\u3001\u6975\u6027\u5316\u5408\u7269\u306eGC\u5206\u6790\u3067\u62bc\u3055\u3048\u3066\u304a\u304d\u305f\u3044\u8981\u70b9\u3092\u6574\u7406\u3057\u305f\u8cc7\u6599\u3092\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u3002\u5185\u5bb9\u306e\u78ba\u8a8d\u3084\u30c1\u30fc\u30e0\u5185\u5171\u6709\u7528\u306e\u8cc7\u6599\u3068\u3057\u3066\u6d3b\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/strong>\u261e<strong>\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\u306b\u306f\u7c21\u5358\u306a\u30d5\u30a9\u30fc\u30e0\u5165\u529b\u304c\u5fc5\u8981\u3067\u3059\u3002<em>\u3053\u3061\u3089<\/em>\u304b\u3089\u30a2\u30af\u30bb\u30b9\u3057\u3066\u304f\u3060\u3055\u3044\uff01<\/strong>\u261c<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-align-center has-theme-palette-9-color has-text-color has-background has-link-color wp-elements-314db5c0c2aa95954c2a69fbd1d2aa67\" style=\"background-color:#1586ed;margin-top:10px;margin-bottom:10px;font-size:30px\"><strong>\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09<\/strong><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-8f8baae60faac2ef9cc6beb42cc3ef25\" style=\"font-size:18px\">Q1. WAX\u30ab\u30e9\u30e0\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u3001\u306a\u305c\u4ed6\u306e\u30ab\u30e9\u30e0\u3088\u308a\u3082\u300c\u6e29\u5ea6\u5236\u5fa1\u300d\u304c\u91cd\u8981\u8996\u3055\u308c\u308b\u306e\u3067\u3059\u304b\uff1f<\/h3>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>A1. WAX\u30ab\u30e9\u30e0\u306e\u4fdd\u6301\u6319\u52d5\u306f\u3001\u5438\u7740\u30fb\u5206\u914d\u306b\u95a2\u308f\u308b\u30a8\u30f3\u30bf\u30eb\u30d4\u30fc\u5909\u5316\uff08\u0394H\uff09\u306b\u5f37\u304f\u652f\u914d\u3055\u308c\u3066\u3044\u308b\u305f\u3081\u3067\u3059\u3002PEG\uff08\u30dd\u30ea\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff09\u306f\u5206\u6790\u5bfe\u8c61\u7269\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u975e\u5e38\u306b\u5f37\u304f\u3001 \u0394H\u304c\u5927\u304d\u304f\u306a\u308b\u50be\u5411\u304c\u3042\u308a\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u300c\u6e29\u5ea6\u306e\u308f\u305a\u304b\u306a\u5909\u5316\u304c\u4fdd\u6301\u6642\u9593\u3092\u5927\u304d\u304f\u5909\u52d5\u3055\u305b\u308b\u300d\u3068\u3044\u3046\u7279\u6027\u3092\u6301\u3064\u305f\u3081\u3001\u6e29\u5ea6\u6761\u4ef6\u306f\u5358\u306b\u6642\u9593\u3092\u8abf\u6574\u3059\u308b\u305f\u3081\u3060\u3051\u3067\u306a\u304f\u3001\u8fd1\u63a5\u6210\u5206\u306e\u5206\u96e2\uff08\u9078\u629e\u6027\uff09\u3092\u7cbe\u5bc6\u306b\u8a2d\u8a08\u3059\u308b\u305f\u3081\u306e\u91cd\u8981\u306a\u30d1\u30e9\u30e1\u30fc\u30bf\u30fc\u3068\u3057\u3066\u6271\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-e1b8c78a3b8aed4c9ede28611929e3e0\" style=\"font-size:18px\">Q2. \u300cWAX\u30ab\u30e9\u30e0\u306f\u6c34\u306b\u5f31\u3044\u300d\u3068\u3044\u3046\u30a4\u30e1\u30fc\u30b8\u304c\u3042\u308a\u307e\u3059\u304c\u3001\u6c34\u6eb6\u6db2\u8a66\u6599\u3092\u76f4\u63a5\u6ce8\u5165\u3057\u3066\u3082\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u304b\uff1f<\/h3>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>A2. \u73fe\u4ee3\u306e\u5316\u5b66\u7d50\u5408\u578bWAX\u30ab\u30e9\u30e0\u3001\u7279\u306b Rtx-Wax \u3067\u3042\u308c\u3070\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u3002Rtx-Wax\u306f\u7279\u6b8a\u306a\u67b6\u6a4b\u5264\u3092\u63a1\u7528\u3057\u3066\u304a\u308a\u3001\u6c34\u6eb6\u6db2\u3092\u30b9\u30d7\u30ea\u30c3\u30c8\u30ec\u30b9\u3067600\u56de\u4ee5\u4e0a\u76f4\u63a5\u6ce8\u5165\u3057\u3066\u3082\u3001\u4fdd\u6301\u6642\u9593\u3084\u30d4\u30fc\u30af\u5f62\u72b6\uff08\u30d7\u30ed\u30d4\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u3084\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\u306a\u3069\uff09\u306b\u5909\u5316\u304c\u306a\u3044\u3053\u3068\u304c\u5b9f\u8a3c\u3055\u308c\u3066\u3044\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u6c34\u5206\u91cf\u304c\u591a\u3044\u30b5\u30f3\u30d7\u30eb\u306f\u5bff\u547d\u3092\u7e2e\u3081\u308b\u8981\u56e0\u306b\u306f\u306a\u308b\u305f\u3081\u3001\u53ef\u80fd\u306a\u9650\u308a\u8131\u6c34\u64cd\u4f5c\u3092\u884c\u3046\u3053\u3068\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u304c\u3001Rtx-Wax\u306f\u6c34\u6ce8\u5165\u306b\u5bfe\u3057\u3066\u6975\u3081\u3066\u9ad8\u3044\u5805\u7262\u6027\u3092\u5099\u3048\u3066\u3044\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-8b61f18a796b686b9ed79d07e9497acf\" style=\"font-size:18px\">Q3. \u6709\u6a5f\u9178\u3084\u30a2\u30df\u30f3\u3092\u5206\u6790\u3059\u308b\u969b\u3001\u5e38\u306b\u300c\u8a98\u5c0e\u4f53\u5316\u300d\u3084\u300c\u30ab\u30e9\u30e0\u30d7\u30e9\u30a4\u30df\u30f3\u30b0\u300d\u3092\u884c\u3046\u5fc5\u8981\u304c\u3042\u308a\u307e\u3059\u304b\uff1f<\/h3>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>A3. \u5c02\u7528\u8a2d\u8a08\u306eWAX\u30ab\u30e9\u30e0\u3092\u4f7f\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u305d\u308c\u3089\u306e\u624b\u9593\u3092\u7701\u304f\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li>\u9178\u6027\u5316\u5408\u7269\uff08\u6709\u6a5f\u9178\u30fb\u8102\u80aa\u9178\u306a\u3069\uff09\uff1a Stabilwax-DA \u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u9178\u6027\u5b98\u80fd\u57fa\u306e\u5c0e\u5165\u306b\u3088\u308a\u5438\u7740\u304c\u6291\u5236\u3055\u308c\u308b\u305f\u3081\u3001\u8a98\u5c0e\u4f53\u5316\u306a\u3057\u3067\u5206\u6790\u3067\u304d\u307e\u3059\u3002<\/li>\n\n\n\n<li>\u5869\u57fa\u6027\u5316\u5408\u7269\uff08\u30a2\u30df\u30f3\u985e\u306a\u3069\uff09\uff1a Stabilwax-DB \u3092\u4f7f\u7528\u3059\u308c\u3070\u3001\u5185\u58c1\u306e\u30a2\u30eb\u30ab\u30ea\u8868\u9762\u51e6\u7406\u306b\u3088\u308a\u5438\u7740\u304c\u6291\u3048\u3089\u308c\u308b\u305f\u3081\u3001\u5206\u6790\u524d\u306b\u30b5\u30f3\u30d7\u30eb\u3092\u4f55\u5ea6\u3082\u6ce8\u5165\u3057\u3066\u5438\u7740\u70b9\u3092\u6f70\u3059\u300c\u30ab\u30e9\u30e0\u30d7\u30e9\u30a4\u30df\u30f3\u30b0\u300d\u3068\u3044\u3046\u7169\u96d1\u306a\u64cd\u4f5c\u304c\u4e0d\u8981\u306b\u306a\u308a\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-right has-text-color has-link-color has-small-font-size wp-elements-6cd339aa5787dd9e0f7f9809735c9f5a\" style=\"color:#ea0ad8\"><strong>\u3053\u306e\u3088\u3046\u306a\u7591\u554f\u306b\u3064\u3044\u3066\u3055\u3089\u306b\u8a73\u3057\u304f\u8aac\u660e\u3057\u3066\u3044\u308b\u3001<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kw202602\/kiwami-2026-wax-column-expert\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u3061\u3089\u306e\u8a18\u4e8b\uff08\u89e3\u8aac\u7de8\uff09<\/a>\u3082\u662f\u975e\u3054\u89a7\u304f\u3060\u3055\u3044\uff01<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size\"><a href=\"https:\/\/discover.restek.com\/wp-admin\/post.php?post=88320&amp;action=edit#mokuji\"><strong>\u261d\u76ee\u6b21\u306b\u623b\u308b<\/strong><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>GC\u3067\u306e\u6975\u6027\u5316\u5408\u7269\uff08\u30a2\u30eb\u30b3\u30fc\u30eb\u3001\u6709\u6a5f\u9178\u7b49\uff09\u5206\u6790\u306b\u4e0d\u53ef\u6b20\u306aWAX\u30ab\u30e9\u30e0\u3092\u5fb9\u5e95\u89e3\u8aac\u3002PEG\u56fa\u5b9a\u76f8\u306e\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\uff08\u6c34\u7d20\u7d50\u5408\u30fb\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\uff09\u3084\u6e29\u5ea6\u5236\u5fa1\u306b\u3088\u308b\u9078\u629e\u6027\u8a2d\u8a08\u3092\u8a73\u3057\u304f\u7d39\u4ecb\u3057\u307e\u3059\u3002\u6c34\u6ce8\u5165\u306b\u5f37\u3044Rtx-Wax\u3084\u4f4e\u30d6\u30ea\u30fc\u30c9\u306aStabilwax-MS\u306a\u3069\u7528\u9014\u5225\u306e\u9078\u3073\u65b9\u3082\u6e80\u8f09\u3002\u5206\u6790\u7cbe\u5ea6\u3092\u9ad8\u3081\u305f\u3044\u65b9\u5fc5\u898b\u3067\u3059\u3002<\/p>\n","protected":false},"author":11,"featured_media":88777,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[2552],"resource-technique":[2340],"ppma_author":[414],"class_list":["post-88320","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs-ja","product-library-gas-chromatography-products-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"product-library":[{"value":2552,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/kiwami_base_v1-1024x535.png",1024,535,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":441,"filter":"raw","cat_ID":794,"category_count":441,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/88320","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=88320"}],"version-history":[{"count":40,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/88320\/revisions"}],"predecessor-version":[{"id":93451,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/88320\/revisions\/93451"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/88777"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=88320"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=88320"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=88320"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=88320"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=88320"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=88320"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=88320"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=88320"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=88320"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}