{"id":90764,"date":"2026-03-24T07:01:42","date_gmt":"2026-03-24T07:01:42","guid":{"rendered":"https:\/\/discover.restek.com\/?p=90764"},"modified":"2026-05-29T01:20:10","modified_gmt":"2026-05-29T01:20:10","slug":"kiwami-2026-plot-column-introduction","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202603\/kiwami-2026-plot-column-introduction","title":{"rendered":"PLOT\u30ab\u30e9\u30e0\u3068\u306f\uff1f \uff5cGC\u30ac\u30b9\u5206\u6790\u306b\u5fc5\u9808\u306e\u5438\u7740\u578b\u30ab\u30e9\u30e0\u306e\u57fa\u790e\u30fb\u9078\u3073\u65b9\u30fb\u4f7f\u3044\u65b9"},"content":{"rendered":"\n<p class=\"has-text-align-right has-theme-palette-1-color has-text-color has-link-color has-small-font-size wp-elements-796144eecfeddfc940047d8c7fbfc16c\">\u203b\u6c17\u306b\u306a\u3063\u305f\u30ad\u30fc\u30ef\u30fc\u30c9\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u3055\u3089\u306b\u6df1\u5800\u308a\u3057\u305f\u8a18\u4e8b<strong><em>\uff08<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert\" target=\"_blank\" rel=\"noreferrer noopener\">\u89e3\u8aac\u7de8<\/a>\uff09<\/em><\/strong>\u3082\u305c\u3072\u3054\u89a7\u304f\u3060\u3055\u3044\uff01<\/p>\n\n\n<style>.wp-block-kadence-iconlist.kt-svg-icon-list-items90764_ef7755-10:not(.this-stops-third-party-issues){margin-top:0px;margin-bottom:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items90764_ef7755-10 ul.kt-svg-icon-list:not(.this-prevents-issues):not(.this-stops-third-party-issues):not(.tijsloc){margin-top:0px;margin-right:0px;margin-bottom:var(--global-kb-spacing-sm, 1.5rem);margin-left:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items90764_ef7755-10 ul.kt-svg-icon-list{grid-row-gap:5px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items90764_ef7755-10 ul.kt-svg-icon-list .kt-svg-icon-list-item-wrap .kt-svg-icon-list-single{margin-right:10px;}.kt-svg-icon-list-items90764_ef7755-10 ul.kt-svg-icon-list .kt-svg-icon-list-level-0 .kt-svg-icon-list-single svg{font-size:20px;}<\/style>\n<div class=\"wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items90764_ef7755-10 kt-svg-icon-list-columns-1 alignnone\"><ul class=\"kt-svg-icon-list\"><style>.kt-svg-icon-list-item-90764_d5ce9a-9e .kt-svg-icon-list-single{font-size:30px !important;color:#f60909 !important;}.kt-svg-icon-list-item-90764_d5ce9a-9e .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-90764_d5ce9a-9e\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fas_star kt-svg-icon-list-single\"><svg viewBox=\"0 0 576 512\"  fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M259.3 17.8L194 150.2 47.9 171.5c-26.2 3.8-36.7 36.1-17.7 54.6l105.7 103-25 145.5c-4.5 26.3 23.2 46 46.4 33.7L288 439.6l130.7 68.7c23.2 12.2 50.9-7.4 46.4-33.7l-25-145.5 105.7-103c19-18.5 8.5-50.8-17.7-54.6L382 150.2 316.7 17.8c-11.7-23.6-45.6-23.9-57.4 0z\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\"><strong>\u3053\u306e\u8a18\u4e8b\u306b\u306f\u3053\u3093\u306a\u3053\u3068\u304c\u66f8\u3044\u3066\u3042\u308a\u307e\u3059\uff01<\/strong><\/span><\/li>\n<\/ul><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1429\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u9ad8\u63ee\u767a\u6027\u6210\u5206\u5206\u6790\u306e\u6975\u81f4-scaled.png\" alt=\"\" class=\"wp-image-90765\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u9ad8\u63ee\u767a\u6027\u6210\u5206\u5206\u6790\u306e\u6975\u81f4-scaled.png 2560w, https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u9ad8\u63ee\u767a\u6027\u6210\u5206\u5206\u6790\u306e\u6975\u81f4-300x167.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u9ad8\u63ee\u767a\u6027\u6210\u5206\u5206\u6790\u306e\u6975\u81f4-1024x571.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u9ad8\u63ee\u767a\u6027\u6210\u5206\u5206\u6790\u306e\u6975\u81f4-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u9ad8\u63ee\u767a\u6027\u6210\u5206\u5206\u6790\u306e\u6975\u81f4-1536x857.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u9ad8\u63ee\u767a\u6027\u6210\u5206\u5206\u6790\u306e\u6975\u81f4-2048x1143.png 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n\n\n<p>PLOT\u30ab\u30e9\u30e0\u306f\u3001WCOT\u30ab\u30e9\u30e0\u3067\u306f\u4fdd\u6301\u304c\u4e0d\u5341\u5206\u306a<strong>\u6c38\u4e45\u30ac\u30b9\u3084\u9ad8\u63ee\u767a\u6027\u6210\u5206<\/strong>\u3092\u3001\u591a\u5b54\u8cea\u5438\u7740\u5264\u3078\u306e\u300c\u5438\u7740\u300d\u306b\u3088\u3063\u3066\u9ad8\u52b9\u7387\u306b\u5206\u96e2\u3059\u308bGC\u30ab\u30e9\u30e0\u3067\u3059\u3002\u7279\u306b<strong>H\u2082\u3001O\u2082\u3001N\u2082\u3001CO\u3001C1\u301cC6\u70ad\u5316\u6c34\u7d20\u306a\u3069\u306e\u30ac\u30b9\u5206\u6790<\/strong>\u3067\u4e0d\u53ef\u6b20\u306a\u9078\u629e\u80a2\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"has-theme-palette-3-color has-text-color has-link-color wp-elements-1594009ebc49eb57996f0c52b6263ca0\">\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u306b\u304a\u3044\u3066\u3001\u4e00\u822c\u7684\u306aWCOT\u30ab\u30e9\u30e0\uff08\u6db2\u76f8\u5206\u914d\u30ab\u30e9\u30e0\uff09\u3067\u306f\u6c38\u4e45\u30ac\u30b9\u3084\u4f4e\u7d1a\u70ad\u5316\u6c34\u7d20\u306e\u4fdd\u6301\u304c\u4e0d\u5341\u5206\u306b\u306a\u308b\u3053\u3068\u304c\u591a\u304f\u3001\u3053\u308c\u3089\u306e\u5206\u96e2\u3092\u5f97\u610f\u3068\u3059\u308bPLOT\u30ab\u30e9\u30e0\uff08\u591a\u5b54\u8cea\u5c64\u30aa\u30fc\u30d7\u30f3\u30c1\u30e5\u30d6\u30e9\u30ab\u30e9\u30e0\uff09\u304c\u30ac\u30b9\u5206\u6790\u5206\u91ce\u3067\u5e83\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002<a>\u672c\u8a18\u4e8b\u3067\u306f\u3001PLOT\u30ab\u30e9\u30e0\u306e\u69cb\u9020\u3068\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u57fa\u790e\u304b\u3089\u3001\u5438\u7740\u5264\u306e\u9078\u5b9a\u3084\u904b\u7528\u4e0a\u306e\u6ce8\u610f\u70b9\u307e\u3067\u3092\u6574\u7406\u3057\u307e\u3059\u3002<\/a><\/p>\n\n\n\n<div class=\"wp-block-group has-theme-palette-8-background-color has-background is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-theme-palette-1-color has-text-color has-link-color has-medium-font-size wp-elements-595241f5c21206d88967f5ca09aad0b7\" id=\"mokuji\"><strong>\u25ce\u76ee\u6b21\u25ce<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><a href=\"#mokuji1\" data-type=\"internal\" data-id=\"#mokuji1\">\u306a\u305cPLOT\u30ab\u30e9\u30e0\u304c\u30ac\u30b9\u30fb\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u3067\u5fc5\u8981\u306a\u306e\u304b<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji2\" data-type=\"internal\" data-id=\"#mokuji2\">PLOT\u30ab\u30e9\u30e0\u306e\u57fa\u790e<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji3\">\u76ee\u7684\u5225\u30fb\u5438\u7740\u5264\u306e\u9078\u3073\u65b9<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji4\" data-type=\"internal\" data-id=\"#mokuji4\">PLOT\u30ab\u30e9\u30e0\u3092\u4f7f\u3046\u4e0a\u3067\u306e\u57fa\u672c\u7684\u306a\u6ce8\u610f\u70b9<\/a><\/li>\n\n\n\n<li><a href=\"#mokuji5\" data-type=\"internal\" data-id=\"#mokuji5\">\u3055\u3044\u3054\u306b\uff1aPLOT\u30ab\u30e9\u30e0\u3092\u5b89\u5b9a\u3057\u3066\u6d3b\u7528\u3059\u308b\u305f\u3081\u306e\u8003\u3048\u65b9<\/a><\/li>\n<\/ol>\n<\/div>\n\n\n\n<hr class=\"wp-block-separator has-text-color has-theme-palette-9-color has-alpha-channel-opacity has-theme-palette-9-background-color has-background\"\/>\n\n\n\n<div style=\"height:70px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji1\" style=\"font-size:38px;line-height:1.4\">1. \u306a\u305cPLOT\u30ab\u30e9\u30e0\u304c\u30ac\u30b9\u30fb\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u3067\u5fc5\u8981\u306a\u306e\u304b<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-c7ee5e2a69e4d6c213ef39dc162dc32f\" style=\"font-size:18px\">\u4f1d\u7d71\u7684\u306a\u5145\u586b\u30ab\u30e9\u30e0\u304b\u3089\u306e\u9032\u5316<\/h3>\n\n\n\n<p>PLOT\u30ab\u30e9\u30e0\u306f\u30011950\u5e74\u4ee3\u5f8c\u534a\u306bGolay\u306b\u3088\u3063\u3066\u63d0\u6848\u3055\u308c\u3001\u5f93\u6765\u306e\u5145\u586b\u30ab\u30e9\u30e0\uff08Packed Column\uff09\u306b\u4ee3\u308f\u308b\u5f37\u529b\u306a\u30c4\u30fc\u30eb\u3068\u3057\u3066\u767a\u5c55\u3057\u307e\u3057\u305f\u3002\u5145\u586b\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u3001<strong>\u5206\u96e2\u52b9\u7387\u306e\u5411\u4e0a<\/strong>\u3001<strong>\u5206\u6790\u6642\u9593\u77ed\u7e2e<\/strong>\u3001\u305d\u3057\u3066<strong>\u30ab\u30e9\u30e0\u306e\u8fc5\u901f\u306a\u518d\u751f\u304c\u53ef\u80fd<\/strong>\u3068\u3044\u3046<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert#mokuji11\" target=\"_blank\" rel=\"noreferrer noopener\">\u5927\u304d\u306a\u30e1\u30ea\u30c3\u30c8<\/a>\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-8b2421d239ca75612d0f2e50671ef55d\" style=\"font-size:18px\">WCOT\u30ab\u30e9\u30e0\u306e\u9650\u754c\u3068\u300c\u4fdd\u6301\u529b\u300d\u306e\u5b9a\u7fa9<\/h3>\n\n\n\n<p>\u6cb8\u70b9\u304c50\u2103\u4ee5\u4e0b\u306e\u8efd\u8cea\u6210\u5206\uff08\u6c38\u4e45\u30ac\u30b9\u3001\u4f4e\u7d1a\u70ad\u5316\u6c34\u7d20\u306a\u3069\uff09\u306b\u304a\u3044\u3066\u3001\u4e00\u822c\u7684\u306aWCOT\u30ab\u30e9\u30e0\u3067\u306f\u4fdd\u6301\u529b\u304c\u4e0d\u8db3\u3057\u307e\u3059\u3002\u4fdd\u6301\u3092\u5f37\u3081\u308b\u305f\u3081\u306b\u6db2\u76f8\u306e\u819c\u539a\u30921\u00b5m\u4ee5\u4e0a\u306b\u539a\u304f\u3059\u308b\u30a2\u30d7\u30ed\u30fc\u30c1\u3082\u3042\u308a\u307e\u3059\u304c\u3001\u819c\u539a\u304c\u5897\u3059\u3068\u7406\u8ad6\u6bb5\u6570\uff08N\uff09\u304c\u6025\u6fc0\u306b\u4f4e\u4e0b\u3057\u3001\u5206\u96e2\u52b9\u7387\u304c\u640d\u306a\u308f\u308c\u308b\u3068\u3044\u3046\u91cd\u5927\u306a\u6b20\u70b9\u304c\u3042\u308a\u307e\u3059\u3002<br>PLOT\u30ab\u30e9\u30e0\u306f\u3001<strong>\u591a\u5b54\u8cea\u5438\u7740\u5264\u306e\u8868\u9762\u76f8\u4e92\u4f5c\u7528\u3092\u5229\u7528<\/strong>\u3059\u308b\u3053\u3068\u3067\u3001WCOT\u30ab\u30e9\u30e0\u306e<strong>\u6570\u5341\u500d\u7a0b\u5ea6\u306e\u4fdd\u6301\u529b<\/strong>\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5ba4\u6e29\u4ee5\u4e0a\u306e\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u8a2d\u5b9a\u3067\u3082\u3001\u9ad8\u63ee\u767a\u6027\u6210\u5206\u3092\u30b7\u30e3\u30fc\u30d7\u306b\u3001\u304b\u3064\u9ad8\u52b9\u7387\u306b\u5206\u96e2\u30fb\u4fdd\u6301\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji2\" style=\"font-size:38px;line-height:1.4\">2. PLOT\u30ab\u30e9\u30e0\u306e\u57fa\u790e<\/h2>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-4ec1a391a89d256313eff0ac405d9a26\" style=\"font-size:18px\">WCOT\u30ab\u30e9\u30e0\u3068\u306e\u9055\u3044\u3068\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u8003\u3048\u65b9<\/h3>\n\n\n\n<p><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert#mokuji12\" target=\"_blank\" rel=\"noreferrer noopener\">PLOT\u30ab\u30e9\u30e0<\/a>\u306f\u3001Porous (thin) Layer Open Tubular\u306e\u7565\u79f0\u306b\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0\u306f\u3001\u5358\u306a\u308b\u300c\u5206\u914d\u300d\u3067\u306f\u306a\u304f\u3001\u591a\u5b54\u8cea\u5438\u7740\u5264\u3078\u306e\u300c\u5438\u7740\u3068\u8131\u7740\u300d\u306e\u7e70\u308a\u8fd4\u3057\u306b\u57fa\u3065\u3044\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1434\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/2-GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\u3068\u7269\u7406\u5316\u5b66\u7684\u69cb\u9020\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-scaled.png\" alt=\"\" class=\"wp-image-93463\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/2-GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\u3068\u7269\u7406\u5316\u5b66\u7684\u69cb\u9020\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-scaled.png 2560w, https:\/\/discover.restek.com\/wp-content\/uploads\/2-GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\u3068\u7269\u7406\u5316\u5b66\u7684\u69cb\u9020\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-300x168.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/2-GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\u3068\u7269\u7406\u5316\u5b66\u7684\u69cb\u9020\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-1024x573.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/2-GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\u3068\u7269\u7406\u5316\u5b66\u7684\u69cb\u9020\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-768x430.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/2-GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\u3068\u7269\u7406\u5316\u5b66\u7684\u69cb\u9020\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-1536x860.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/2-GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\u3068\u7269\u7406\u5316\u5b66\u7684\u69cb\u9020\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-2048x1147.png 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-ae3cf66c3f6fb6b4599b1756daff6362\" style=\"font-size:18px\">3\u3064\u306e\u4e3b\u8981\u306a\u76f8\u4e92\u4f5c\u7528<\/h3>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>\u5438\u7740\u5264\u306e\u7a2e\u985e\u306b\u3088\u308a\u3001\u4ee5\u4e0b\u306e<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert#mokuji21\" target=\"_blank\" rel=\"noreferrer noopener\">3\u3064\u306e\u30e1\u30ab\u30cb\u30ba\u30e0<\/a>\u304c\u5358\u72ec\u3001\u3042\u308b\u3044\u306f\u8907\u5408\u7684\u306b\u50cd\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<ul style=\"margin-right:10px;margin-left:10px\" class=\"wp-block-list\">\n<li><strong>\u30b5\u30a4\u30ba\u6392\u9664\uff08\u5206\u5b50\u3075\u308b\u3044\uff09<\/strong>\uff1a \u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\u7b49\u3067\u898b\u3089\u308c\u3001\u7d30\u5b54\u5f84\u3088\u308a\u3082\u5c0f\u3055\u306a\u5206\u5b50\u3092\u9078\u629e\u7684\u306b\u53d6\u308a\u8fbc\u307f\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u5f37\u3044\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\uff08\u6975\u6027\uff09<\/strong>\uff1a \u30a2\u30eb\u30df\u30ca\u7b49\u306e\u8868\u9762\u304c\u3001\u5206\u6790\u7a2e\u306e\u6975\u6027\u3068\u5f37\u304f\u76f8\u4e92\u4f5c\u7528\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u8a98\u5c0e\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\uff08\u5206\u6975\u6027\uff09<\/strong>\uff1a \u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc\u3067\u898b\u3089\u308c\u3001\u30d5\u30a7\u30cb\u30eb\u57fa\u306a\u3069\u306e\u5b98\u80fd\u57fa\u304c\u5206\u6790\u7a2e\u3068\u306e\u5206\u6975\u306b\u3088\u308b\u76f8\u4e92\u4f5c\u7528\u3067\u4fdd\u6301\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-98d587356261ec855fcb758cef98903d\" style=\"font-size:18px\">\u69cb\u9020\u306e\u7279\u7570\u6027<\/h3>\n\n\n\n<p>PLOT\u30ab\u30e9\u30e0\u306e<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert#mokuji22\" target=\"_blank\" rel=\"noreferrer noopener\">\u6700\u5927\u306e\u7279\u5fb4<\/a>\u306f\u3001\u30c1\u30e5\u30fc\u30d6\u5185\u58c1\u306b\u5f62\u6210\u3055\u308c\u305f<strong>5\uff5e50 \u00b5m\u3068\u3044\u3046\u539a\u3055\u306e\u7c92\u5b50\u5c64<\/strong>\u306b\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u4e00\u822c\u7684\u306a\u6db2\u76f8\u30ab\u30e9\u30e0\u306e\u819c\u539a\uff08\u901a\u5e380.25 \u00b5m\uff5e1 \u00b5m\u7a0b\u5ea6\uff09\u3068\u6bd4\u8f03\u3059\u308b\u3068\u3001<strong>\u6570\u5341\u500d\u304b\u3089\u767e\u500d\u8fd1\u3044\u539a\u307f<\/strong>\u3067\u3059\u3002<br>\u3053\u306e\u300c\u539a\u819c\u304b\u3064\u591a\u5b54\u8cea\u300d\u306a\u69cb\u9020\u306b\u306f\u3001\u300c<strong>WCOT\u30ab\u30e9\u30e0\u306e\u6570\u5341\u500d\u3068\u3044\u3046\u5f37\u529b\u306a\u4fdd\u6301\u529b<\/strong>\u300d\u3001\u300c<strong>\u9ad8\u3044\u5206\u96e2\u52b9\u7387\u3092\u7dad\u6301\u3057\u305f\u307e\u307e\u306e\u3001\u81a8\u5927\u306a\u8868\u9762\u7a4d\u3092\u6d3b\u304b\u3057\u305f\u5927\u304d\u306a\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf\u306e\u78ba\u4fdd<\/strong>\u300d\u3068\u3044\u3046\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u300c\u539a\u819c\u306a\u306e\u306b\u5206\u5b50\u79fb\u52d5\u304c\u30b9\u30e0\u30fc\u30ba\u300d\u3068\u3044\u3046\u7279\u7570\u306a\u69cb\u9020\u3053\u305d\u304c\u3001\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3044\u3066PLOT\u30ab\u30e9\u30e0\u304c\u552f\u4e00\u7121\u4e8c\u3067\u3042\u308b\u7406\u7531\u3067\u3059\u3002<\/p>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji3\" style=\"font-size:38px;line-height:1.4\">3. \u76ee\u7684\u5225\u30fb\u5438\u7740\u5264\u306e<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert#mokuji35\">\u9078\u3073\u65b9<\/a><\/h2>\n\n\n\n<h3 class=\"wp-block-heading has-theme-palette-1-color has-text-color has-link-color wp-elements-3387d2a61f0e529142259cfa24bf2797\" style=\"font-size:18px\">Restek\u306e\u72ec\u81ea\u6280\u8853\uff1aPLOT\u5206\u6790\u306b\u304a\u3051\u308b\u5805\u7262\u6027\u3068\u518d\u73fe\u6027\u306e\u9769\u65b0<\/h3>\n\n\n\n<p>Restek\u306f\u72ec\u81ea\u6280\u8853\u306b\u3088\u308a\u3001<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert#mokuji31\" target=\"_blank\" rel=\"noreferrer noopener\">PLOT\u30ab\u30e9\u30e0\u306e\u5bbf\u547d\u7684\u306a\u8ab2\u984c<\/a>\u3092\u514b\u670d\u3057\u307e\u3057\u305f\u3002<br>\u307e\u305a\u3001\u72ec\u81ea\u306e\u5b89\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9\u306b\u3088\u308a\u3001\u5f93\u6765\u306e\u8ab2\u984c\u3067\u3042\u3063\u305f\u7c92\u5b50\u5265\u96e2\u3092\u5b9f\u8cea\u7684\u306b\u6392\u9664\u3057\u3001\u30ce\u30a4\u30ba\u3084\u88c5\u7f6e\u6c5a\u67d3\u3092\u9632\u3050\u9a5a\u7570\u7684\u306a\u5805\u7262\u6027\u3092\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u696d\u754c\u552f\u4e00\u306e\u54c1\u8cea\u7ba1\u7406\u6307\u6a19\u300c<strong><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert#mokuji32\" target=\"_blank\" rel=\"noreferrer noopener\">\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\u5024\uff09<\/a><\/strong>\u300d\u3092\u5c0e\u5165\u3057\u3001\u30ab\u30e9\u30e0\u9593\u306e\u6d41\u91cf\u7279\u6027\u3092\u4e00\u5b9a\u306b\u5236\u5fa1\u3059\u308b\u3053\u3068\u306b\u6210\u529f\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/3-PLOT\u56fa\u5b9a\u76f8\u306e\u9032\u5316-1024x572.png\" alt=\"\" class=\"wp-image-90782\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/3-PLOT\u56fa\u5b9a\u76f8\u306e\u9032\u5316-1024x572.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/3-PLOT\u56fa\u5b9a\u76f8\u306e\u9032\u5316-300x168.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/3-PLOT\u56fa\u5b9a\u76f8\u306e\u9032\u5316-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/3-PLOT\u56fa\u5b9a\u76f8\u306e\u9032\u5316-1536x858.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/3-PLOT\u56fa\u5b9a\u76f8\u306e\u9032\u5316-2048x1144.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<p>\u3053\u308c\u306b\u3088\u308a\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u4ea4\u63db\u3057\u3066\u3082\u300c\u6d41\u91cf\u8a2d\u5b9a\u3092\u5909\u3048\u305a\u306b\u540c\u3058\u4fdd\u6301\u6642\u9593\u304c\u5f97\u3089\u308c\u308b\u300d\u9ad8\u3044\u518d\u73fe\u6027\u3092\u4fdd\u8a3c\u3057\u307e\u3059\u3002F\u5024\u306f\u5168\u3066\u306e\u5206\u6790\u8a3c\u660e\u66f8\uff08COA\uff09\u306b\u660e\u8a18\u3055\u308c\u3066\u304a\u308a\u3001\u30e1\u30bd\u30c3\u30c9\u518d\u691c\u8a0e\u306e\u624b\u9593\u3068\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3092\u5287\u7684\u306b\u524a\u6e1b\u3059\u308b\u300c\u4fe1\u983c\u306e\u7cbe\u5bc6\u30c7\u30d0\u30a4\u30b9\u300d\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/4-\u518d\u73fe\u6027\u6539\u9769F\u5024\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\uff09-1-1024x572.png\" alt=\"\" class=\"wp-image-93489\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/4-\u518d\u73fe\u6027\u6539\u9769F\u5024\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\uff09-1-1024x572.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/4-\u518d\u73fe\u6027\u6539\u9769F\u5024\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\uff09-1-300x168.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/4-\u518d\u73fe\u6027\u6539\u9769F\u5024\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\uff09-1-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/4-\u518d\u73fe\u6027\u6539\u9769F\u5024\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\uff09-1-1536x858.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/4-\u518d\u73fe\u6027\u6539\u9769F\u5024\uff08\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\uff09-1-2048x1144.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>\u5206\u6790\u6210\u529f\u306e\u9375\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306b\u542b\u307e\u308c\u308b<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert#mokuji33\" target=\"_blank\" rel=\"noreferrer noopener\">\u6c34\u5206\u306e\u7279\u6027<\/a>\u3092\u7406\u89e3\u3057\u3001\u6700\u9069\u306a\u300c\u76f8\u300d\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u306b\u3042\u308a\u307e\u3059\u3002\u3055\u307e\u3056\u307e\u306a\u5206\u6790\u5bfe\u8c61\u306e\u4e8b\u4f8b\u3092\u4ee5\u4e0b\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30e9\u30a4\u30d6\u30e9\u30ea\u3067\u78ba\u8a8d\u3057\u3001\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u969b\u306e\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01<\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong>\u53c2\u8003\u60c5\u5831\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/plot-chromatogram-library\" target=\"_blank\" rel=\"noreferrer noopener\">PLOT\u30ab\u30e9\u30e0\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30e9\u30a4\u30d6\u30e9\u30ea<\/a><\/strong><\/p>\n<\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1430\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/5-\u6c4e\u7528\u30ab\u30e9\u30e0\u57fa\u672c\u306e3\u9078-scaled.png\" alt=\"\" class=\"wp-image-90794\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/5-\u6c4e\u7528\u30ab\u30e9\u30e0\u57fa\u672c\u306e3\u9078-scaled.png 2560w, https:\/\/discover.restek.com\/wp-content\/uploads\/5-\u6c4e\u7528\u30ab\u30e9\u30e0\u57fa\u672c\u306e3\u9078-300x168.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/5-\u6c4e\u7528\u30ab\u30e9\u30e0\u57fa\u672c\u306e3\u9078-1024x572.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/5-\u6c4e\u7528\u30ab\u30e9\u30e0\u57fa\u672c\u306e3\u9078-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/5-\u6c4e\u7528\u30ab\u30e9\u30e0\u57fa\u672c\u306e3\u9078-1536x858.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/5-\u6c4e\u7528\u30ab\u30e9\u30e0\u57fa\u672c\u306e3\u9078-2048x1144.png 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-theme-palette-9-color has-theme-palette-6-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-c41b5af994a6ff97b4d80a15a146d179\"><strong>\u57fa\u672c\u2460 \u3000\u5e0c\u30ac\u30b9\u5206\u96e2\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19723\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Msieve 5A<\/a>\uff09<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Msieve-5A-6.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Msieve 5A \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/strong><\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"margin-right:10px;margin-left:10px\">\u7528\u9014\uff1a H\u2082\u3001O\u2082\u3001N\u2082\u3001CO\u3001CH\u2084\u306a\u3069\u306e\u6c38\u4e45\u30ac\u30b9\u3001\u304a\u3088\u3073\u5e0c\u30ac\u30b9\u306e\u5206\u96e2<\/li>\n\n\n\n<li style=\"margin-right:10px;margin-left:10px\">\u7279\u9577\uff1a\u4e00\u9178\u5316\u70ad\u7d20\uff08CO\uff09\u306b\u304a\u3044\u3066\u3001\u4ed6\u793e\u88fd\u3067\u767a\u751f\u3057\u3084\u3059\u3044\u30c6\u30fc\u30ea\u30f3\u30b0\u3092\u6291\u3048\u305f\u975e\u5e38\u306b\u826f\u597d\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-theme-palette-9-color has-theme-palette-6-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-27ee38451ee978aec3b1bac1cedd5486\"><strong>\u57fa\u672c\u2461\u3000\u70ad\u5316\u6c34\u7d20\u5206\u96e2\u30a2\u30eb\u30df\u30ca\uff08Rt-Alumina BOND\u30b7\u30ea\u30fc\u30ba\uff09<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><strong><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-KCI-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\"><strong>Rt-Alumina BOND<\/strong> KCI \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/a><\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\">                                     <a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-Na2SO4-3.xlsx\"> <strong><strong>Rt-Alumina BOND<\/strong> Na<sub>2<\/sub>SO<sub>4<\/sub> \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/strong><\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"margin-right:10px;margin-left:10px\">\u7528\u9014\uff1a C1\uff5eC6\u70ad\u5316\u6c34\u7d20\u304a\u3088\u3073\u305d\u306e\u7570\u6027\u4f53\u5206\u6790\u306e\u6c7a\u5b9a\u7248<\/li>\n\n\n\n<li style=\"margin-right:10px;margin-left:10px\">\u7279\u9577\uff1a \u30a2\u30eb\u30df\u30ca\u306f\u975e\u5e38\u306b\u6d3b\u6027\u304c\u9ad8\u3044\u305f\u3081\u3001<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19776\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND KCl<\/a>\uff08\u4f4e\u6975\u6027\uff09\u3084<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19775\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND Na\u2082SO\u2084<\/a>\uff08\u6975\u6027\uff09\u306a\u3069\u306e\u7121\u6a5f\u5869\u3067\u51e6\u7406\u3057\u3001\u9078\u629e\u6027\u3092\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3057\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-theme-palette-9-color has-theme-palette-6-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-db58572ce2a20ab024db5b34ddfb3509\"><strong>\u57fa\u672c\u2462\u3000\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc\uff08<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19744\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Q-BOND<\/a>\uff09<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Q-BOND-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><strong>Rt-Q-BOND<\/strong> \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/strong><\/a><\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"margin-right:10px;margin-left:10px\">\u7528\u9014\uff1a \u6eb6\u5a92\u3001CO\u2082\u3001\u6975\u6027\u63ee\u767a\u6027\u7269\u8cea\u306e\u5206\u6790\u3002<\/li>\n\n\n\n<li style=\"margin-right:10px;margin-left:10px\">\u7279\u9577\uff1a 100%\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\uff08DVB\uff09\u76f8\u3002\u6c34\u306e\u5f71\u97ff\u3092\u53d7\u3051\u305a\u3001\u4e8c\u9178\u5316\u70ad\u7d20\uff08CO2\uff09\u3084\u6eb6\u5a92\u3092\u30b7\u30e3\u30fc\u30d7\u306b\u6eb6\u51fa\u3055\u305b\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p>\u3055\u3089\u306b\u3001PLOT\u30ab\u30e9\u30e0\u306f\u3001\u72ec\u81ea\u306e\u9078\u629e\u6027\u3068\u56fa\u5b9a\u76f8\u306e\u5438\u7740\u6a5f\u69cb\u306b\u3088\u308a\u3001\u5e38\u6e29\u3067\u6c38\u4e45\u30ac\u30b9\u3084\u8efd\u8cea\u70ad\u5316\u6c34\u7d20\u3092\u5206\u96e2\u3067\u304d\u308b\u70b9\u304c\u6700\u5927\u306e\u30e1\u30ea\u30c3\u30c8\u3067\u3059\u304c\u3001\u305d\u306e\u5fdc\u7528\u7bc4\u56f2\u306f\u5358\u306a\u308b\u30ac\u30b9\u5206\u6790\u306b\u7559\u307e\u308a\u307e\u305b\u3093\u3002Restek\u306e\u72ec\u81ea\u6280\u8853\u306f\u3001\u5f93\u6765\u306e\u9650\u754c\u3092\u8d85\u3048\u305f<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert#mokuji34\" target=\"_blank\" rel=\"noreferrer noopener\">\u6e29\u5ea6\u5b89\u5b9a\u6027<\/a>\u3084\u5805\u7262\u6027\u3092\u63d0\u4f9b\u3057\u3001<strong>\u5e45\u5e83\u3044\u5206\u6790\u30cb\u30fc\u30ba<\/strong>\u306b\u5fdc\u3048\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1430\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/6-\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\u5c02\u9580\u306e3\u9078-scaled.png\" alt=\"\" class=\"wp-image-90803\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/6-\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\u5c02\u9580\u306e3\u9078-scaled.png 2560w, https:\/\/discover.restek.com\/wp-content\/uploads\/6-\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\u5c02\u9580\u306e3\u9078-300x168.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/6-\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\u5c02\u9580\u306e3\u9078-1024x572.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/6-\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\u5c02\u9580\u306e3\u9078-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/6-\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\u5c02\u9580\u306e3\u9078-1536x858.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/6-\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\u5c02\u9580\u306e3\u9078-2048x1144.png 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-theme-palette-8-color has-theme-palette-5-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-24953d99896b1065fbe28f3e11ac4cb5\"><strong>\u7279\u5b9a\u7528\u9014\u2460\u3000\u9ad8\u5206\u5b50\u91cf\u70ad\u5316\u6c34\u7d20\u3078\u306e\u5bfe\u5fdc\u3068\u8fc5\u901f\u306a\u30ab\u30e9\u30e0\u518d\u751f <\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center has-medium-font-size\"><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-MAPD-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><strong>Rt-Alumina BOND\/MAPD<\/strong> \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/strong><\/a><\/p>\n\n\n\n<p class=\"has-text-align-left\"><br><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19781\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/MAPD<\/a><\/strong>\u30ab\u30e9\u30e0\u306f\u3001\u6700\u9ad8\u4f7f\u7528\u6e29\u5ea6\u3092250\u2103\u307e\u3067\u62e1\u5f35\u3057\u305f\u72ec\u81ea\u8a2d\u8a08\u3068\u306a\u3063\u3066\u304a\u308a\u3001\u30c9\u30c7\u30ab\u30f3\uff08C12\uff09\u307e\u3067\u306e<strong>\u70ad\u5316\u6c34\u7d20\u3092\u8fc5\u901f\u306b\u6eb6\u51fa<\/strong>\u3055\u305b\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002\u307e\u305f\u3001\u3053\u306e\u9ad8\u6e29\u5bfe\u5fdc\u306b\u3088\u308a\u3001\u6c34\u5206\u306b\u66dd\u9732\u3055\u308c\u305f\u5f8c\u306e\u30ab\u30e9\u30e0\u518d\u751f\u6642\u9593\u3092\u5927\u5e45\u306b\u77ed\u7e2e\u3067\u304d\u308b\u70b9\u3082\u5b9f\u52d9\u4e0a\u306e\u5927\u304d\u306a\u5229\u70b9\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-theme-palette-8-color has-theme-palette-5-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-79ede5ad673301961fc6de8a19915a5e\"><strong>\u7279\u5b9a\u7528\u9014\u2461\u3000\u4e0d\u7d14\u7269\u5206\u6790\u306b\u304a\u3051\u308b\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3068\u30ec\u30b9\u30dd\u30f3\u30b9 <\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-U-BOND-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><strong>Rt-U-BOND<\/strong> \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/strong><\/a><\/p>\n\n\n\n<p><br><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19772\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-U-BOND<\/a><\/strong>\u30ab\u30e9\u30e0\u306f\u6975\u3081\u3066\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u6301\u3061\u3001H\u2082S\u3084COS\u3001\u30e1\u30eb\u30ab\u30d7\u30bf\u30f3\u306a\u3069\u306e\u8150\u98df\u6027\u786b\u9ec4\u5316\u5408\u7269\u3084\u30db\u30eb\u30e0\u30a2\u30eb\u30c7\u30d2\u30c9\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u512a\u308c\u305f\u30d4\u30fc\u30af\u5f62\u72b6\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-theme-palette-8-color has-theme-palette-5-background-color has-text-color has-background has-link-color has-medium-font-size wp-elements-2d323bbe22c018325b21a44bb9870196\"><strong>\u7279\u5b9a\u7528\u9014\u2462\u3000\u7279\u5b9a\u7528\u9014\u306b\u7279\u5316\u3057\u305f\u9078\u629e\u6027\uff08CFC\u30fb\u30d5\u30ed\u30f3\u985e\uff09<\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\"><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-CFC-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><strong>Rt-Alumina BOND\/CFC<\/strong> \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/strong><\/a><\/p>\n\n\n\n<p><br><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19763\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/CFC<\/a><\/strong>\u30ab\u30e9\u30e0\u306f\u3001\u63ee\u767a\u6027\u30cf\u30ed\u30b2\u30f3\u5316\u5408\u7269\u3001\u7279\u306bCFC\uff08\u30af\u30ed\u30ed\u30d5\u30eb\u30aa\u30ed\u30ab\u30fc\u30dc\u30f3\uff09\u306e\u4fdd\u6301\u306b\u6700\u9069\u5316\u3055\u308c\u305f\u72ec\u81ea\u306e\u88fd\u54c1\u3067\u3059\u3002\u5fb9\u5e95\u3057\u305f\u4e0d\u6d3b\u6027\u5316\u306b\u3088\u308a\u3001\u5e83\u7bc4\u56f2\u306eCFC\u7570\u6027\u4f53\u3092\u5e38\u6e29\u4ee5\u4e0a\u3067\u9ad8\u7cbe\u5ea6\u306b\u5206\u96e2\u30fb\u5b9a\u91cf\u3059\u308b\u3053\u3068\u3092\u53ef\u80fd\u306b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji4\" style=\"font-size:38px;line-height:1.4\">4. <strong>PLOT\u30ab\u30e9\u30e0\u3092\u4f7f\u3046\u4e0a\u3067\u306e\u57fa\u672c\u7684\u306a\u6ce8\u610f\u70b9<\/strong><\/h2>\n\n\n\n<p>\u8cea\u91cf\u5206\u6790\u8a08\uff08MS\uff09\u7b49\u306e\u30c7\u30ea\u30b1\u30fc\u30c8\u306a\u88c5\u7f6e\u3092\u4fdd\u8b77\u3059\u308b\u305f\u3081\u3001Restek\u306f\u4ee5\u4e0b\u306e\u904b\u7528\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n<style>.wp-block-kadence-iconlist.kt-svg-icon-list-items90764_6ad5d2-f2:not(.this-stops-third-party-issues){margin-top:0px;margin-bottom:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items90764_6ad5d2-f2 ul.kt-svg-icon-list:not(.this-prevents-issues):not(.this-stops-third-party-issues):not(.tijsloc){margin-top:0px;margin-right:0px;margin-bottom:var(--global-kb-spacing-sm, 1.5rem);margin-left:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items90764_6ad5d2-f2 ul.kt-svg-icon-list{grid-row-gap:5px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items90764_6ad5d2-f2 ul.kt-svg-icon-list .kt-svg-icon-list-item-wrap .kt-svg-icon-list-single{margin-right:10px;}.kt-svg-icon-list-items90764_6ad5d2-f2 ul.kt-svg-icon-list .kt-svg-icon-list-level-0 .kt-svg-icon-list-single svg{font-size:20px;}<\/style>\n<div class=\"wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items90764_6ad5d2-f2 kt-svg-icon-list-columns-1 alignnone\"><ul class=\"kt-svg-icon-list\"><style>.kt-svg-icon-list-item-90764_b9acc2-2b .kt-svg-icon-list-single{font-size:58px !important;}.kt-svg-icon-list-item-90764_b9acc2-2b .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-90764_b9acc2-2b\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_alertOctagon kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><polygon points=\"7.86 2 16.14 2 22 7.86 22 16.14 16.14 22 7.86 22 2 16.14 2 7.86 7.86 2\"\/><line x1=\"12\" y1=\"8\" x2=\"12\" y2=\"12\"\/><line x1=\"12\" y1=\"16\" x2=\"12\" y2=\"16\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\"><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19774\" target=\"_blank\" rel=\"noreferrer noopener\">\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7<\/a>\u306e\u63a5\u7d9a<\/strong>\uff1a \u5265\u96e2\u7c92\u5b50\u3092\u7269\u7406\u7684\u306b\u30c8\u30e9\u30c3\u30d7\u3059\u308b\u305f\u3081\u306b\u3001MS\u63a5\u7d9a\u6642\u306a\u3089\u30ab\u30e9\u30e0\u5f8c\u6bb5\u306b5\u301c15 m\u306e\u6db2\u76f8\u30ab\u30e9\u30e0\uff08Rxi-1ms\u7b49\uff09\u3092\u63a5\u7d9a\u3059\u308b\u3053\u3068\u3092\u63a8\u5968\u3057\u307e\u3059\u3002\u691c\u51fa\u5668\u304cMS\u3067\u306f\u306a\u3044\u5834\u5408\u306b\u306f\u30012.5 m\u9577\u306e\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u304c\u78ba\u5b9f\u3067\u3059\u3002<\/span><\/li>\n\n\n<style>.kt-svg-icon-list-item-90764_33a73b-f1 .kt-svg-icon-list-single{font-size:58px !important;}.kt-svg-icon-list-item-90764_33a73b-f1 .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-90764_33a73b-f1\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_alertOctagon kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><polygon points=\"7.86 2 16.14 2 22 7.86 22 16.14 16.14 22 7.86 22 2 16.14 2 7.86 7.86 2\"\/><line x1=\"12\" y1=\"8\" x2=\"12\" y2=\"12\"\/><line x1=\"12\" y1=\"16\" x2=\"12\" y2=\"16\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\"><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20402\" target=\"_blank\" rel=\"noreferrer noopener\">\u30d7\u30ec\u30b9\u30bf\u30a4\u30c8\u30b3\u30cd\u30af\u30bf<\/a>\u306e\u4f7f\u7528<\/strong>\uff1a\u30ac\u30e9\u30b9\u88fd\u306e\u30d7\u30ec\u30b9\u30bf\u30a4\u30c8\u30b3\u30cd\u30af\u30bf\u306a\u3089\u3001\u30d4\u30fc\u30af\u3092\u5e83\u3052\u305a\u7dba\u9e97\u306b\u4fdd\u3063\u305f\u307e\u307e\u3001\u5265\u96e2\u7c92\u5b50\u306e\u6d41\u51fa\u3092\u9632\u3052\u307e\u3059\u3002\u4e0d\u6d3b\u6027\u306a\u63a5\u7d9a\u3068\u88c5\u7f6e\u4fdd\u8b77\u306b\u6700\u9069\u3067\u3059\u3002<\/span><\/li>\n\n\n<style>.kt-svg-icon-list-item-90764_5da3a4-44 .kt-svg-icon-list-single{font-size:58px !important;}.kt-svg-icon-list-item-90764_5da3a4-44 .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-90764_5da3a4-44\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fe_alertOctagon kt-svg-icon-list-single\"><svg viewBox=\"0 0 24 24\"  fill=\"none\" stroke=\"currentColor\" stroke-width=\"2\" stroke-linecap=\"round\" stroke-linejoin=\"round\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><polygon points=\"7.86 2 16.14 2 22 7.86 22 16.14 16.14 22 7.86 22 2 16.14 2 7.86 7.86 2\"\/><line x1=\"12\" y1=\"8\" x2=\"12\" y2=\"12\"\/><line x1=\"12\" y1=\"16\" x2=\"12\" y2=\"16\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\"><strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/79728-273\" target=\"_blank\" rel=\"noreferrer noopener\">\u91d1\u5c5e\u88fdMXT\u30ab\u30e9\u30e0<\/a><\/strong>\uff1a \u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u3068\u540c\u7b49\u306e\u6027\u80fd\u3092\u6301\u3064\u91d1\u5c5e\u88fdMXT PLOT\u30ab\u30e9\u30e0\u306fSiltek\u51e6\u7406\u3092\u65bd\u3057\u305f\u30b9\u30c6\u30f3\u30ec\u30b9\u88fd\u3002\u885d\u6483\u306b\u5f37\u3044\u305f\u3081\u3001\u30d7\u30ed\u30bb\u30b9GC\u3084\u30dd\u30fc\u30bf\u30d6\u30ebGC\u3067\u306e\u904e\u9177\u306a\u904b\u7528\u3001\u5c0f\u5f84\u5dfb\u304d\uff083.5\u30a4\u30f3\u30c1\uff09\u306e\u72ed\u3044\u30b9\u30da\u30fc\u30b9\u306b\u6700\u9069\u3067\u3059\u3002<\/span><\/li>\n<\/ul><\/div>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"2560\" height=\"1430\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/7-\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3068\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\uff08\u672c\u793e\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-scaled.png\" alt=\"\" class=\"wp-image-94991\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/7-\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3068\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\uff08\u672c\u793e\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-scaled.png 2560w, https:\/\/discover.restek.com\/wp-content\/uploads\/7-\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3068\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\uff08\u672c\u793e\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-300x168.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/7-\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3068\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\uff08\u672c\u793e\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-1024x572.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/7-\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3068\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\uff08\u672c\u793e\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/7-\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3068\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\uff08\u672c\u793e\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-1536x858.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/7-\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3068\u30b9\u30c6\u30f3\u30ec\u30b9\u30ab\u30e9\u30e0\uff08\u672c\u793e\u30ec\u30d3\u30e5\u30fc\u5f8c\u4fee\u6b63\u6e08\uff09-2048x1144.png 2048w\" sizes=\"auto, (max-width: 2560px) 100vw, 2560px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji5\" style=\"font-size:38px;line-height:1.4\">5. <strong>\u3055\u3044\u3054\u306b\uff1aPLOT\u30ab\u30e9\u30e0\u3092\u5b89\u5b9a\u3057\u3066\u6d3b\u7528\u3059\u308b\u305f\u3081\u306e\u8003\u3048\u65b9<\/strong><\/h2>\n\n\n\n<p>Restek\u3067\u306f\u3001\u72ec\u81ea\u6280\u8853\u306b\u3088\u308b\u5b89\u5b9a\u3057\u305f\u56fa\u5b9a\u76f8\u8a2d\u8a08\u306b\u52a0\u3048\u3001\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\u5024\uff09\u3092\u7528\u3044\u305f\u54c1\u8cea\u7ba1\u7406\u3092\u884c\u3046\u3053\u3068\u3067\u3001PLOT\u30ab\u30e9\u30e0\u306e\u4fdd\u6301\u7279\u6027\u3084\u518d\u73fe\u6027\u3092\u7ba1\u7406\u3057\u3066\u3044\u307e\u3059\u3002<br>PLOT\u30ab\u30e9\u30e0\u306f\u3001\u305d\u306e\u69cb\u9020\u7684\u7279\u6027\u3092\u7406\u89e3\u3057\u305f\u3046\u3048\u3067\u9069\u5207\u306b\u9078\u629e\u30fb\u904b\u7528\u3059\u308b\u3053\u3068\u3067\u3001\u6c38\u4e45\u30ac\u30b9\u3084\u8efd\u8cea\u6210\u5206\u306e\u5206\u6790\u306b\u304a\u3044\u3066\u5b89\u5b9a\u3057\u305f\u6027\u80fd\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u672c\u7a3f\u3067\u306f\u3001\u305d\u306e\u57fa\u672c\u7684\u306a\u8003\u3048\u65b9\u3068\u4f4d\u7f6e\u3065\u3051\u3092\u6574\u7406\u3057\u307e\u3057\u305f\u3002<br>\u672c\u7a3f\u3067\u306f\u89e6\u308c\u307e\u305b\u3093\u3067\u3057\u305f\u304c\u3001PLOT\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u6761\u4ef6\u3092\u8ab0\u3067\u3082\u7c21\u5358\u306b\u30b7\u30df\u30e5\u30ec\u30fc\u30c8\u3067\u304d\u308b<strong><a href=\"https:\/\/ez.restek.com\/proezgc\/ja\" target=\"_blank\" rel=\"noreferrer noopener\">Pro <em>EZ<\/em>GC Chromatogram Modeler<\/a><\/strong>\u3092\u6d3b\u7528\u3059\u308c\u3070\u3001\u30e1\u30bd\u30c3\u30c9\u958b\u767a\u306e\u6642\u77ed\u306b\u3082\u306a\u308a\u307e\u3059\u3002\u305c\u3072\u3001\u3053\u3046\u3057\u305f\u30c4\u30fc\u30eb\u3082\u6d3b\u7528\u3057\u306a\u304c\u3089\u3001PLOT\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u3092\u691c\u8a0e\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p>\u672c\u7a3f\u306e\u5185\u5bb9\u3067\u3042\u308b\u3001PLOT\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u3067\u62bc\u3055\u3048\u3066\u304a\u304d\u305f\u3044\u8981\u70b9\u3092\u7c21\u6f54\u306b\u6574\u7406\u3057\u305f\u8cc7\u6599\u3092\u7528\u610f\u3057\u3066\u3044\u307e\u3059\u3002\u8a18\u4e8b\u5185\u5bb9\u3092\u78ba\u8a8d\u7528\u306b\u307e\u3068\u3081\u305f\u3082\u306e\u3067\u3059\u306e\u3067\u3001\u793e\u5185\u5171\u6709\u3084\u4fdd\u5b58\u7528\u3068\u3057\u3066\u6d3b\u7528\u3057\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p class=\"has-text-align-center has-theme-palette-9-color has-text-color has-background has-link-color has-medium-font-size wp-elements-66446459e79923a8aee027e01344061c\" style=\"background-color:#1510e3\"><strong>\uff3b\u8cc7\u6599\u3092\u30c0\u30a6\u30f3\u30ed\u30fc\u30c9\uff08\u30d5\u30a9\u30fc\u30e0\u5165\u529b\u3042\u308a\uff09\uff3d<\/strong><\/p>\n\n\n\n<p><em>\u672c\u8a18\u4e8b\u306f\u3001Restek\u30a6\u30a7\u30d3\u30ca\u30fc\u3001Journal of Chromatography A\u63b2\u8f09\u306e\u30ec\u30d3\u30e5\u30fc\u8ad6\u6587\u3001\u304a\u3088\u3073LCGC International\u63b2\u8f09\u306e\u6700\u65b0\u6280\u8853\u8cc7\u6599\u306b\u57fa\u3065\u304d\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/em><\/p>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<p class=\"has-text-align-center has-theme-palette-9-color has-text-color has-background has-link-color wp-elements-62ef3f38f646444b03318101452ee1d2\" style=\"background-color:#1586ed;margin-top:10px;margin-bottom:10px;font-size:30px\"><strong>\u3088\u304f\u3042\u308b\u8cea\u554f\uff08FAQ\uff09<\/strong><\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-428a01d2784a83ee93c7095ed7a1cd6d\" style=\"font-size:18px\">Q1. PLOT\u30ab\u30e9\u30e0\u3068WCOT\u30ab\u30e9\u30e0\u306e\u9055\u3044\u306f\uff1f<\/h3>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>A1. WCOT\u306f\u6db2\u76f8\u3078\u306e\u5206\u914d\u306b\u57fa\u3065\u304f\u5206\u96e2\u3001PLOT\u306f\u591a\u5b54\u8cea\u5438\u7740\u5264\u3078\u306e\u5438\u7740\u306b\u57fa\u3065\u304f\u5206\u96e2\u3067\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-d492c6e071ee34785350afc8e728d803\" style=\"font-size:18px\">Q2. \u6c34\u5206\u306fPLOT\u30ab\u30e9\u30e0\u306b\u5f71\u97ff\u3057\u307e\u3059\u304b\uff1f<\/h3>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>A2. \u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\u304a\u3088\u3073\u30a2\u30eb\u30df\u30ca\u30b7\u30b9\u30c6\u30e0\u306f\u6c34\u3092\u5f37\u304f\u5438\u7740\u3059\u308b\u305f\u3081\u3001\u518d\u751f\u304c\u5fc5\u8981\u3067\u3059\u3002 \u305f\u3060\u3057\u3001\u5341\u5206\u306a\u91cf\u306e\u6c34\u304c\u30ab\u30e9\u30e0\u306b\u5c0e\u5165\u3055\u308c\u308b\u3068\u3001\u56de\u5fa9\u4e0d\u53ef\u80fd\u306a\u30c0\u30e1\u30fc\u30b8\u3092\u53d7\u3051\u3001\u518d\u751f\u3067\u304d\u306a\u304f\u306a\u308a\u307e\u3059\u3002<br>\u4e00\u65b9\u3001\u975e\u6975\u6027\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u30b7\u30b9\u30c6\u30e0\u306fRt-Q-BOND\u306a\u3069\u3001\u6c34\u3092\u5438\u7740\u305b\u305a\u3001\u30b7\u30e3\u30fc\u30d7\u306b\u6eb6\u51fa\u3057\u307e\u3059\u3002\u305f\u3060\u3057\u3001\u591a\u5b54\u6027\u30dd\u30ea\u30de\u30fc\u306e\u6975\u6027\u304c\u9ad8\u304f\u306a\u308b\u306b\u3064\u308c\uff08Q&lt;QS&lt;S&lt;U\u3001Rt-U-BOND\u304c\u6700\u3082\u6975\u6027\u304c\u9ad8\u3044\uff09\u3001\u6c34\u3068\u306e\u76f8\u4e92\u4f5c\u7528\u304c\u751f\u3058\u308b\u53ef\u80fd\u6027\u304c\u3042\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h3 class=\"wp-block-heading has-theme-palette-2-color has-text-color has-link-color wp-elements-20bc69caa191051541e19b225a048a11\" style=\"font-size:18px\">Q3. MS\u306b\u63a5\u7d9a\u3057\u3066\u3082\u554f\u984c\u3042\u308a\u307e\u305b\u3093\u304b\uff1f<\/h3>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p>A3. PLOT\u30ab\u30e9\u30e0\u3092MS\u691c\u51fa\u5668\u3068\u7d44\u307f\u5408\u308f\u305b\u3066\u4f7f\u7528\u3059\u308b\u3053\u3068\u306f\u63a8\u5968\u3055\u308c\u307e\u305b\u3093\u3002\u305f\u3060\u3057\u3001\u4f7f\u7528\u3059\u308b\u5834\u5408\u306f\u3001\u7c92\u5b50\u5265\u96e2\u5bfe\u7b56\u3068\u3057\u3066\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u3092\u63a5\u7d9a\u3057\u3066\u304f\u3060\u3055\u3044\uff084\uff0e\u3092\u53c2\u7167\u3057\u3066\u304f\u3060\u3055\u3044\uff09\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-text-align-right has-text-color has-link-color has-small-font-size wp-elements-35c4b4f6ffe155876486b149e3643c01\" style=\"color:#ea0ad8\"><strong>\u3053\u306e\u3088\u3046\u306a\u7591\u554f\u306b\u3064\u3044\u3066\u3055\u3089\u306b\u8a73\u3057\u304f\u8aac\u660e\u3057\u3066\u3044\u308b\u3001\u3053\u3061\u3089\u306e\u8a18\u4e8b\uff08<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert\" target=\"_blank\" rel=\"noreferrer noopener\">\u89e3\u8aac\u7de8<\/a>\uff09\u3082\u662f\u975e\u3054\u89a7\u304f\u3060\u3055\u3044\uff01<\/strong><\/p>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>\u203b\u6c17\u306b\u306a\u3063\u305f\u30ad\u30fc\u30ef\u30fc\u30c9\u3092\u30af\u30ea\u30c3\u30af\u3057\u3066\u3055\u3089\u306b\u6df1\u5800\u308a\u3057\u305f\u8a18\u4e8b\uff08\u89e3\u8aac\u7de8\uff09\u3082\u305c\u3072\u3054\u89a7\u304f\u3060\u3055\u3044\uff01 PLOT\u30ab\u30e9\u30e0\u306f\u3001WCOT\u30ab\u30e9\u30e0\u3067\u306f\u4fdd\u6301\u304c\u4e0d\u5341\u5206\u306a\u6c38\u4e45\u30ac\u30b9\u3084\u9ad8\u63ee\u767a\u6027\u6210\u5206\u3092\u3001\u591a\u5b54\u8cea\u5438\u7740\u5264\u3078\u306e\u300c\u5438\u7740\u300d\u306b\u3088\u3063\u3066\u9ad8\u52b9\u7387\u306b\u5206\u96e2\u3059\u308bGC\u30ab\u30e9\u30e0\u3067\u3059\u3002\u7279\u306bH\u2082\u3001O\u2082\u3001N\u2082\u3001CO\u3001C1\u301cC6\u70ad\u5316\u6c34\u7d20\u306a\u3069\u306e\u30ac\u30b9\u5206\u6790\u3067\u4e0d\u53ef\u6b20\u306a\u9078\u629e\u80a2\u3068\u306a\u308a\u307e\u3059\u3002 \u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\uff08GC\uff09\u306b\u304a\u3044\u3066\u3001\u4e00\u822c\u7684\u306aWCOT\u30ab\u30e9\u30e0\uff08\u6db2\u76f8\u5206\u914d\u30ab\u30e9\u30e0\uff09\u3067\u306f\u6c38\u4e45\u30ac\u30b9\u3084\u4f4e\u7d1a\u70ad\u5316\u6c34\u7d20\u306e\u4fdd\u6301\u304c\u4e0d\u5341\u5206\u306b\u306a\u308b\u3053\u3068\u304c\u591a\u304f\u3001\u3053\u308c\u3089\u306e\u5206\u96e2\u3092\u5f97\u610f\u3068\u3059\u308bPLOT\u30ab\u30e9\u30e0\uff08\u591a\u5b54\u8cea\u5c64\u30aa\u30fc\u30d7\u30f3\u30c1\u30e5\u30d6\u30e9\u30ab\u30e9\u30e0\uff09\u304c\u30ac\u30b9\u5206\u6790\u5206\u91ce\u3067\u5e83\u304f\u7528\u3044\u3089\u308c\u3066\u3044\u307e\u3059\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001PLOT\u30ab\u30e9\u30e0\u306e\u69cb\u9020\u3068\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u57fa\u790e\u304b\u3089\u3001\u5438\u7740\u5264\u306e\u9078\u5b9a\u3084\u904b\u7528\u4e0a\u306e\u6ce8\u610f\u70b9\u307e\u3067\u3092\u6574\u7406\u3057\u307e\u3059\u3002 \u25ce\u76ee\u6b21\u25ce 1. \u306a\u305cPLOT\u30ab\u30e9\u30e0\u304c\u30ac\u30b9\u30fb\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u3067\u5fc5\u8981\u306a\u306e\u304b \u4f1d\u7d71\u7684\u306a\u5145\u586b\u30ab\u30e9\u30e0\u304b\u3089\u306e\u9032\u5316 PLOT\u30ab\u30e9\u30e0\u306f\u30011950\u5e74\u4ee3\u5f8c\u534a\u306bGolay\u306b\u3088\u3063\u3066\u63d0\u6848\u3055\u308c\u3001\u5f93\u6765\u306e\u5145\u586b\u30ab\u30e9\u30e0\uff08Packed Column\uff09\u306b\u4ee3\u308f\u308b\u5f37\u529b\u306a\u30c4\u30fc\u30eb\u3068\u3057\u3066\u767a\u5c55\u3057\u307e\u3057\u305f\u3002\u5145\u586b\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u3001\u5206\u96e2\u52b9\u7387\u306e\u5411\u4e0a\u3001\u5206\u6790\u6642\u9593\u77ed\u7e2e\u3001\u305d\u3057\u3066\u30ab\u30e9\u30e0\u306e\u8fc5\u901f\u306a\u518d\u751f\u304c\u53ef\u80fd\u3068\u3044\u3046\u5927\u304d\u306a\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002 WCOT\u30ab\u30e9\u30e0\u306e\u9650\u754c\u3068\u300c\u4fdd\u6301\u529b\u300d\u306e\u5b9a\u7fa9 \u6cb8\u70b9\u304c50\u2103\u4ee5\u4e0b\u306e\u8efd\u8cea\u6210\u5206\uff08\u6c38\u4e45\u30ac\u30b9\u3001\u4f4e\u7d1a\u70ad\u5316\u6c34\u7d20\u306a\u3069\uff09\u306b\u304a\u3044\u3066\u3001\u4e00\u822c\u7684\u306aWCOT\u30ab\u30e9\u30e0\u3067\u306f\u4fdd\u6301\u529b\u304c\u4e0d\u8db3\u3057\u307e\u3059\u3002\u4fdd\u6301\u3092\u5f37\u3081\u308b\u305f\u3081\u306b\u6db2\u76f8\u306e\u819c\u539a\u30921\u00b5m\u4ee5\u4e0a\u306b\u539a\u304f\u3059\u308b\u30a2\u30d7\u30ed\u30fc\u30c1\u3082\u3042\u308a\u307e\u3059\u304c\u3001\u819c\u539a\u304c\u5897\u3059\u3068\u7406\u8ad6\u6bb5\u6570\uff08N\uff09\u304c\u6025\u6fc0\u306b\u4f4e\u4e0b\u3057\u3001\u5206\u96e2\u52b9\u7387\u304c\u640d\u306a\u308f\u308c\u308b\u3068\u3044\u3046\u91cd\u5927\u306a\u6b20\u70b9\u304c\u3042\u308a\u307e\u3059\u3002PLOT\u30ab\u30e9\u30e0\u306f\u3001\u591a\u5b54\u8cea\u5438\u7740\u5264\u306e\u8868\u9762\u76f8\u4e92\u4f5c\u7528\u3092\u5229\u7528\u3059\u308b\u3053\u3068\u3067\u3001WCOT\u30ab\u30e9\u30e0\u306e\u6570\u5341\u500d\u7a0b\u5ea6\u306e\u4fdd\u6301\u529b\u3092\u767a\u63ee\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5ba4\u6e29\u4ee5\u4e0a\u306e\u30aa\u30fc\u30d6\u30f3\u6e29\u5ea6\u8a2d\u5b9a\u3067\u3082\u3001\u9ad8\u63ee\u767a\u6027\u6210\u5206\u3092\u30b7\u30e3\u30fc\u30d7\u306b\u3001\u304b\u3064\u9ad8\u52b9\u7387\u306b\u5206\u96e2\u30fb\u4fdd\u6301\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002 \u261d\u76ee\u6b21\u306b\u623b\u308b 2. PLOT\u30ab\u30e9\u30e0\u306e\u57fa\u790e WCOT\u30ab\u30e9\u30e0\u3068\u306e\u9055\u3044\u3068\u4fdd\u6301\u30e1\u30ab\u30cb\u30ba\u30e0\u306e\u8003\u3048\u65b9 PLOT\u30ab\u30e9\u30e0\u306f\u3001Porous (thin) Layer Open Tubular\u306e\u7565\u79f0\u306b\u306a\u308a\u307e\u3059\u3002\u305d\u306e\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0\u306f\u3001\u5358\u306a\u308b\u300c\u5206\u914d\u300d\u3067\u306f\u306a\u304f\u3001\u591a\u5b54\u8cea\u5438\u7740\u5264\u3078\u306e\u300c\u5438\u7740\u3068\u8131\u7740\u300d\u306e\u7e70\u308a\u8fd4\u3057\u306b\u57fa\u3065\u3044\u3066\u3044\u307e\u3059\u3002 3\u3064\u306e\u4e3b\u8981\u306a\u76f8\u4e92\u4f5c\u7528 \u5438\u7740\u5264\u306e\u7a2e\u985e\u306b\u3088\u308a\u3001\u4ee5\u4e0b\u306e3\u3064\u306e\u30e1\u30ab\u30cb\u30ba\u30e0\u304c\u5358\u72ec\u3001\u3042\u308b\u3044\u306f\u8907\u5408\u7684\u306b\u50cd\u304d\u307e\u3059\u3002 \u69cb\u9020\u306e\u7279\u7570\u6027 PLOT\u30ab\u30e9\u30e0\u306e\u6700\u5927\u306e\u7279\u5fb4\u306f\u3001\u30c1\u30e5\u30fc\u30d6\u5185\u58c1\u306b\u5f62\u6210\u3055\u308c\u305f5\uff5e50 \u00b5m\u3068\u3044\u3046\u539a\u3055\u306e\u7c92\u5b50\u5c64\u306b\u3042\u308a\u307e\u3059\u3002\u3053\u308c\u306f\u3001\u4e00\u822c\u7684\u306a\u6db2\u76f8\u30ab\u30e9\u30e0\u306e\u819c\u539a\uff08\u901a\u5e380.25 \u00b5m\uff5e1 \u00b5m\u7a0b\u5ea6\uff09\u3068\u6bd4\u8f03\u3059\u308b\u3068\u3001\u6570\u5341\u500d\u304b\u3089\u767e\u500d\u8fd1\u3044\u539a\u307f\u3067\u3059\u3002\u3053\u306e\u300c\u539a\u819c\u304b\u3064\u591a\u5b54\u8cea\u300d\u306a\u69cb\u9020\u306b\u306f\u3001\u300cWCOT\u30ab\u30e9\u30e0\u306e\u6570\u5341\u500d\u3068\u3044\u3046\u5f37\u529b\u306a\u4fdd\u6301\u529b\u300d\u3001\u300c\u9ad8\u3044\u5206\u96e2\u52b9\u7387\u3092\u7dad\u6301\u3057\u305f\u307e\u307e\u306e\u3001\u81a8\u5927\u306a\u8868\u9762\u7a4d\u3092\u6d3b\u304b\u3057\u305f\u5927\u304d\u306a\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf\u306e\u78ba\u4fdd\u300d\u3068\u3044\u3046\u30e1\u30ea\u30c3\u30c8\u304c\u3042\u308a\u307e\u3059\u3002\u3053\u306e\u300c\u539a\u819c\u306a\u306e\u306b\u5206\u5b50\u79fb\u52d5\u304c\u30b9\u30e0\u30fc\u30ba\u300d\u3068\u3044\u3046\u7279\u7570\u306a\u69cb\u9020\u3053\u305d\u304c\u3001\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3044\u3066PLOT\u30ab\u30e9\u30e0\u304c\u552f\u4e00\u7121\u4e8c\u3067\u3042\u308b\u7406\u7531\u3067\u3059\u3002 \u261d\u76ee\u6b21\u306b\u623b\u308b 3. \u76ee\u7684\u5225\u30fb\u5438\u7740\u5264\u306e\u9078\u3073\u65b9 Restek\u306e\u72ec\u81ea\u6280\u8853\uff1aPLOT\u5206\u6790\u306b\u304a\u3051\u308b\u5805\u7262\u6027\u3068\u518d\u73fe\u6027\u306e\u9769\u65b0 Restek\u306f\u72ec\u81ea\u6280\u8853\u306b\u3088\u308a\u3001PLOT\u30ab\u30e9\u30e0\u306e\u5bbf\u547d\u7684\u306a\u8ab2\u984c\u3092\u514b\u670d\u3057\u307e\u3057\u305f\u3002\u307e\u305a\u3001\u72ec\u81ea\u306e\u5b89\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9\u306b\u3088\u308a\u3001\u5f93\u6765\u306e\u8ab2\u984c\u3067\u3042\u3063\u305f\u7c92\u5b50\u5265\u96e2\u3092\u5b9f\u8cea\u7684\u306b\u6392\u9664\u3057\u3001\u30ce\u30a4\u30ba\u3084\u88c5\u7f6e\u6c5a\u67d3\u3092\u9632\u3050\u9a5a\u7570\u7684\u306a\u5805\u7262\u6027\u3092\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002\u3055\u3089\u306b\u3001\u696d\u754c\u552f\u4e00\u306e\u54c1\u8cea\u7ba1\u7406\u6307\u6a19\u300c\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\u5024\uff09\u300d\u3092\u5c0e\u5165\u3057\u3001\u30ab\u30e9\u30e0\u9593\u306e\u6d41\u91cf\u7279\u6027\u3092\u4e00\u5b9a\u306b\u5236\u5fa1\u3059\u308b\u3053\u3068\u306b\u6210\u529f\u3057\u3066\u3044\u307e\u3059\u3002 \u3053\u308c\u306b\u3088\u308a\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u4ea4\u63db\u3057\u3066\u3082\u300c\u6d41\u91cf\u8a2d\u5b9a\u3092\u5909\u3048\u305a\u306b\u540c\u3058\u4fdd\u6301\u6642\u9593\u304c\u5f97\u3089\u308c\u308b\u300d\u9ad8\u3044\u518d\u73fe\u6027\u3092\u4fdd\u8a3c\u3057\u307e\u3059\u3002F\u5024\u306f\u5168\u3066\u306e\u5206\u6790\u8a3c\u660e\u66f8\uff08COA\uff09\u306b\u660e\u8a18\u3055\u308c\u3066\u304a\u308a\u3001\u30e1\u30bd\u30c3\u30c9\u518d\u691c\u8a0e\u306e\u624b\u9593\u3068\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u3092\u5287\u7684\u306b\u524a\u6e1b\u3059\u308b\u300c\u4fe1\u983c\u306e\u7cbe\u5bc6\u30c7\u30d0\u30a4\u30b9\u300d\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002 \u5206\u6790\u6210\u529f\u306e\u9375\u306f\u3001\u30b5\u30f3\u30d7\u30eb\u306b\u542b\u307e\u308c\u308b\u6c34\u5206\u306e\u7279\u6027\u3092\u7406\u89e3\u3057\u3001\u6700\u9069\u306a\u300c\u76f8\u300d\u3092\u9078\u629e\u3059\u308b\u3053\u3068\u306b\u3042\u308a\u307e\u3059\u3002\u3055\u307e\u3056\u307e\u306a\u5206\u6790\u5bfe\u8c61\u306e\u4e8b\u4f8b\u3092\u4ee5\u4e0b\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30e9\u30a4\u30d6\u30e9\u30ea\u3067\u78ba\u8a8d\u3057\u3001\u6700\u9069\u306a\u30ab\u30e9\u30e0\u3092\u9078\u629e\u3059\u308b\u969b\u306e\u53c2\u8003\u306b\u3057\u3066\u304f\u3060\u3055\u3044\uff01 \u53c2\u8003\u60c5\u5831\uff1aPLOT\u30ab\u30e9\u30e0\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30e9\u30a4\u30d6\u30e9\u30ea \u57fa\u672c\u2460 \u3000\u5e0c\u30ac\u30b9\u5206\u96e2\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\uff08Rt-Msieve 5A\uff09 Rt-Msieve 5A \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8 \u57fa\u672c\u2461\u3000\u70ad\u5316\u6c34\u7d20\u5206\u96e2\u30a2\u30eb\u30df\u30ca\uff08Rt-Alumina BOND\u30b7\u30ea\u30fc\u30ba\uff09 Rt-Alumina BOND KCI \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8 Rt-Alumina BOND Na2SO4 \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8 \u57fa\u672c\u2462\u3000\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc\uff08Rt-Q-BOND\uff09 Rt-Q-BOND \u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8 \u3055\u3089\u306b\u3001PLOT\u30ab\u30e9\u30e0\u306f\u3001\u72ec\u81ea\u306e\u9078\u629e\u6027\u3068\u56fa\u5b9a\u76f8\u306e\u5438\u7740\u6a5f\u69cb\u306b\u3088\u308a\u3001\u5e38\u6e29\u3067\u6c38\u4e45\u30ac\u30b9\u3084\u8efd\u8cea\u70ad\u5316\u6c34\u7d20\u3092\u5206\u96e2\u3067\u304d\u308b\u70b9\u304c\u6700\u5927\u306e\u30e1\u30ea\u30c3\u30c8\u3067\u3059\u304c\u3001\u305d\u306e\u5fdc\u7528\u7bc4\u56f2\u306f\u5358\u306a\u308b\u30ac\u30b9\u5206\u6790\u306b\u7559\u307e\u308a\u307e\u305b\u3093\u3002Restek\u306e\u72ec\u81ea\u6280\u8853\u306f\u3001\u5f93\u6765\u306e\u9650\u754c\u3092\u8d85\u3048\u305f\u6e29\u5ea6\u5b89\u5b9a\u6027\u3084\u5805\u7262\u6027\u3092\u63d0\u4f9b\u3057\u3001\u5e45\u5e83\u3044\u5206\u6790\u30cb\u30fc\u30ba\u306b\u5fdc\u3048\u3066\u3044\u307e\u3059\u3002&#8230;<\/p>\n","protected":false},"author":11,"featured_media":88777,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[414],"class_list":["post-90764","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/kiwami_base_v1-1024x535.png",1024,535,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":441,"filter":"raw","cat_ID":794,"category_count":441,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/90764","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=90764"}],"version-history":[{"count":19,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/90764\/revisions"}],"predecessor-version":[{"id":94995,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/90764\/revisions\/94995"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/88777"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=90764"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=90764"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=90764"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=90764"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=90764"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=90764"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=90764"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=90764"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=90764"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}