{"id":91070,"date":"2026-03-25T07:43:52","date_gmt":"2026-03-25T07:43:52","guid":{"rendered":"https:\/\/discover.restek.com\/?p=91070"},"modified":"2026-05-29T04:04:16","modified_gmt":"2026-05-29T04:04:16","slug":"kiwami-2026-plot-column-expert","status":"publish","type":"post","link":"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202604\/kiwami-2026-plot-column-expert","title":{"rendered":"PLOT\u30ab\u30e9\u30e0\u306e\u5206\u96e2\u539f\u7406\uff5c\u5438\u7740\u30e1\u30ab\u30cb\u30ba\u30e0\u30fb\u4fdd\u6301\u7279\u6027\u3092\u7406\u8ad6\u304b\u3089\u89e3\u8aac"},"content":{"rendered":"\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>PLOT\u30ab\u30e9\u30e0\u306f\u300c\u306a\u305c\u6c38\u4e45\u30ac\u30b9\u3092\u4fdd\u6301\u3067\u304d\u308b\u306e\u304b\uff1f\u300d<br>\u3053\u306e\u554f\u3044\u306b\u5bfe\u3059\u308b\u7b54\u3048\u306f\u3001\u5358\u306a\u308b\u69cb\u9020\u8aac\u660e\u3067\u306f\u306a\u304f\u3001\u5438\u7740\u30e1\u30ab\u30cb\u30ba\u30e0\u30fb\u5206\u96e2\u901f\u5ea6\u8ad6\u30fb\u71b1\u529b\u5b66\u7684\u76f8\u4e92\u4f5c\u7528\u306e\u7406\u89e3\u306b\u3042\u308a\u307e\u3059\u3002<br>\u672c\u8a18\u4e8b\u3067\u306f\u3001<strong>Abraham\u6eb6\u5a92\u548c\u30d1\u30e9\u30e1\u30fc\u30bf\u30e2\u30c7\u30eb<\/strong>\u3001<strong>\u76f8\u6bd4\uff08\u03b2\uff09\u3068\u4fdd\u6301\u6642\u9593\u306e\u95a2\u4fc2<\/strong>\u3001<strong>\u6e29\u5ea6\u4f9d\u5b58\u6027<\/strong>\u3001<strong>\u6c34\u5206\u306e\u71b1\u529b\u5b66\u7684\u5f71\u97ff<\/strong>\u3001\u305d\u3057\u3066Restek\u304c\u5c0e\u5165\u3057\u305f<strong>\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\u5024\uff09\u306b\u3088\u308b\u518d\u73fe\u6027\u7ba1\u7406<\/strong>\u307e\u3067\u3001\u7406\u8ad6\u7684\u80cc\u666f\u304b\u3089\u4f53\u7cfb\u7684\u306b\u89e3\u8aac\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<p><a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202603\/kiwami-2026-plot-column-introduction\" target=\"_blank\" rel=\"noreferrer noopener\">\u5165\u9580\u7de8<\/a>\u304c\u300c\u9078\u3073\u65b9\u30fb\u4f7f\u3044\u65b9\u300d\u3067\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001\u672c\u7a3f\u306f\u300c\u306a\u305c\u305d\u3046\u306a\u308b\u306e\u304b\u300d\u3092\u7406\u89e3\u3059\u308b\u305f\u3081\u306e\u3088\u308a\u5c02\u9580\u7684\u306a\u89e3\u8aac\u7de8\u3067\u3059\u3002<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-group has-theme-palette-8-background-color has-background is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-theme-palette-2-color has-text-color has-link-color has-medium-font-size wp-elements-193c2ed3c388f0fa07530fad60cfb992\" id=\"mokuji\"><strong>\u25ce\u76ee\u6b21<\/strong><\/p>\n\n\n\n<p class=\"has-theme-palette-2-color has-text-color has-link-color wp-elements-cae0760167d00dbd81cadfc47f646f3a\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\"><a href=\"#mokuji11\">1-1. GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\uff1aPacked Column\u304b\u3089Open Tubular Column\u3078<\/a><br><a href=\"#mokuji12\">1-2. Open Tubular Column\u306e3\u3064\u306e\u57fa\u672c\u69cb\u9020\u3068\u7269\u7406\u6a5f\u69cb<\/a><\/p>\n\n\n\n<p class=\"has-theme-palette-2-color has-text-color has-link-color wp-elements-6a7ff496dcd9b003b65775056ba94251\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\"><a href=\"#mokuji21\">2-1. PLOT\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\uff1a\u591a\u5b54\u8cea\u5438\u7740\u5264\u3068\u5206\u96e2\u539f\u7406<\/a><br><a href=\"#mokuji22\">2-2. PLOT\u30ab\u30e9\u30e0\u306e\u69cb\u9020\u7684\u7279\u7570\u6027\u3068\u5206\u96e2\u901f\u5ea6\u8ad6<\/a><\/p>\n\n\n\n<p class=\"has-theme-palette-2-color has-text-color has-link-color wp-elements-a6fe13de4e5ce511028b21415b5a9b32\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\"><a href=\"#mokuji31\">3-1. PLOT\u56fa\u5b9a\u76f8\u306e\u5b89\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9<\/a><br><a href=\"#mokuji32\">3-2. \u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\u5024\uff09\u3068\u518d\u73fe\u6027\u306e\u7ba1\u7406<\/a><br><a href=\"#mokuji33\">3-3. PLOT\u30ab\u30e9\u30e0\u5206\u96e2\u306b\u304a\u3051\u308b\u300c\u6c34\u300d\u306e\u5f71\u97ff<\/a><br><a href=\"#mokuji34\">3-4. \u4fdd\u6301\u4fc2\u6570\u3068\u6e29\u5ea6\u306e\u95a2\u4fc2\uff1a\u9078\u629e\u6027\u3078\u306e\u5f71\u97ff<\/a><br><a href=\"#mokuji35\">3-5. \u6c4e\u7528\u30ab\u30e9\u30e0\uff3b\u57fa\u672c\u306e3\u9078\uff3d\u3068\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\uff3b\u5c02\u9580\u306e3\u9078\uff3d<\/a><\/p>\n\n\n\n<p class=\"has-theme-palette-2-color has-text-color has-link-color wp-elements-405656927908c513ea92181575df675f\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\"><a href=\"#mokuji4\">4. \u5805\u7262\u6027\u306e\u8ffd\u6c42\uff1a\u7c92\u5b50\u5265\u96e2\u5bfe\u7b56\u3068MS\u5206\u6790\u306e\u6700\u9069\u5316<\/a><\/p>\n\n\n\n<p class=\"has-theme-palette-2-color has-text-color has-link-color wp-elements-197e02772628ff60e928072471ce42f5\" style=\"padding-top:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20)\"><a href=\"#mokuji5\">5. \u3055\u3044\u3054\u306b\uff1aPLOT\u30ab\u30e9\u30e0\u3092\u300c\u7406\u89e3\u3057\u3066\u4f7f\u3046\u300d\u305f\u3081\u306b<\/a><\/p>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji11\" style=\"font-size:38px;line-height:1.4\">1-1. GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\uff1aPacked Column\u304b\u3089Open Tubular Column\u3078<\/h2>\n\n\n\n<p>GC\u5206\u96e2\u306e\u6b74\u53f2\u306f\u3001\u7c89\u672b\u72b6\u306e\u56fa\u5b9a\u76f8\u3092\u30c1\u30e5\u30fc\u30d6\u5185\u306b\u8a70\u3081\u8fbc\u3093\u3060\u5145\u586b\u30ab\u30e9\u30e0\uff08Packed Column\uff09\u304b\u3089\u59cb\u307e\u308a\u307e\u3057\u305f\u304c\u3001\u305d\u306e\u5f8c\u306e\u30aa\u30fc\u30d7\u30f3\u30c1\u30e5\u30d6\u30e9\uff08Open Tubular: OT\uff09\u30ab\u30e9\u30e0\u306e\u767b\u5834\u306f\u3001\u5206\u96e2\u79d1\u5b66\u306b\u5927\u304d\u306a\u5909\u5316\u3092\u3082\u305f\u3089\u3057\u307e\u3057\u305f\u3002OT\u30ab\u30e9\u30e0\u306f\u3001\u30c1\u30e5\u30fc\u30d6\u4e2d\u592e\u306b\u969c\u5bb3\u7269\u306e\u306a\u3044\u300c\u958b\u53e3\u6d41\u8def\u300d\u3092\u6301\u3064\u69cb\u9020\u304c\u6700\u5927\u306e\u7279\u5fb4\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5f93\u6765\u306e\u5145\u586b\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u30e1\u30ea\u30c3\u30c8\u3092\u4eab\u53d7\u3067\u304d\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u9ad8\u5206\u96e2\u52b9\u7387<\/strong>\uff1a \u7406\u8ad6\u6bb5\u6570\u9ad8\u3055\uff08HETP\uff09\u304c\u7d040.1mm\u3068\u975e\u5e38\u306b\u4f4e\u304f\u3001\u9ad8\u3044\u7406\u8ad6\u6bb5\u6570\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u9ad8\u901f\u5206\u6790<\/strong>\uff1a \u30ab\u30e9\u30e0\u5185\u306e\u5727\u640d\u304c\u6975\u3081\u3066\u4f4e\u3044\u305f\u3081\u3001\u30ab\u30e9\u30e0\u9577\u3092\u9577\u304f\u3057\u3066\u5206\u96e2\u80fd\u3092\u9ad8\u3081\u3064\u3064\u3001\u6570\u79d2\u5358\u4f4d\u306e\u9ad8\u901f\u5206\u96e2\u304c\u53ef\u80fd\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong>\u8fc5\u901f\u306a\u518d\u751f<\/strong>\uff1a \u30ab\u30e9\u30e0\u306e\u71b1\u5bb9\u91cf\u304c\u5c0f\u3055\u304f\u3001\u6d17\u6d44\u3084\u713c\u304d\u51fa\u3057\u306b\u3088\u308b\u518d\u751f\u304c\u5bb9\u6613\u3067\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji12\" style=\"font-size:38px;line-height:1.4\">1-2. Open Tubular Column\u306e3\u3064\u306e\u57fa\u672c\u69cb\u9020\u3068\u5206\u96e2\u6a5f\u69cb<\/h2>\n\n\n\n<p>\u73fe\u5728\u3001OT\u30ab\u30e9\u30e0\u306f\u305d\u306e\u69cb\u9020\u306b\u3088\u308a\u4e3b\u306b\u4ee5\u4e0b\u306e3\u3064\u306b\u5927\u5225\u3055\u308c\u307e\u3059\u3002<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><strong>WCOT\uff08Wall-Coated Open-Tubular\uff09<\/strong>\uff1a \u5185\u58c1\u306b\u6db2\u76f8\u30dd\u30ea\u30de\u30fc\u3092\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u307e\u305f\u306f\u5316\u5b66\u7d50\u5408\u3057\u305f\u3001\u73fe\u5728\u306eGC\u5206\u6790\u306e\u4e3b\u6d41\u3068\u306a\u308b\u5206\u914d\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong>PLOT\uff08Porous-Layer Open-Tubular\uff09<\/strong>\uff1a \u5185\u58c1\u306b\u591a\u5b54\u8cea\u7c92\u5b50\u3092\u7a4d\u5c64\u3055\u305b\u305f\u3082\u306e\u3067\u3001\u3088\u308a\u6b63\u78ba\u306b\u306fASPOT\uff08Adsorptive Solid-Phase Open-Tubular\uff09\u30ab\u30e9\u30e0\u3068\u547c\u3070\u308c\u307e\u3059\u3002\u672c\u8a18\u4e8b\u306e\u4e3b\u5f79\u3067\u3042\u308a\u3001\u5438\u7740\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc\u3068\u3057\u3066\u6a5f\u80fd\u3057\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>SCOT\uff08Support-Coated Open-Tubular\uff09<\/strong>\uff1a \u5185\u58c1\u306e\u591a\u5b54\u8cea\u7c92\u5b50\u3092\u300c\u62c5\u4f53\u300d\u3068\u3057\u3066\u4f7f\u3044\u3001\u305d\u306e\u4e0a\u306b\u6db2\u76f8\u3092\u4fdd\u6301\u3055\u305b\u305f\u5206\u914d\u3068\u5438\u7740\u306e\u4e2d\u9593\u7684\u306a\u6027\u8cea\u3092\u6301\u3064\u30ab\u30e9\u30e0\u3067\u3059\u3002WCOT\u30bf\u30a4\u30d7\u3078\u306e\u904e\u6e21\u671f\u306b\u4f7f\u308f\u308c\u3001\u73fe\u5728\u3067\u306f\u307b\u3068\u3093\u3069\u898b\u308b\u3053\u3068\u304c\u3042\u308a\u307e\u305b\u3093\u3002<\/li>\n<\/ol>\n\n\n\n<p class=\"has-medium-font-size\"><strong>WCOT\u30ab\u30e9\u30e0\u3068PLOT\u30ab\u30e9\u30e0\u306e\u6bd4\u8f03<\/strong><\/p>\n\n\n<style>.kb-table-container91070_0ef94c-0c{overflow-x:auto;}.kb-table91070_0ef94c-0c td:nth-of-type(1), .kb-table91070_0ef94c-0c th:nth-of-type(1){width:20%;}.kb-table91070_0ef94c-0c td:nth-of-type(2), .kb-table91070_0ef94c-0c th:nth-of-type(2){width:40%;}.kb-table91070_0ef94c-0c td:nth-of-type(3), .kb-table91070_0ef94c-0c th:nth-of-type(3){width:40%;}.kb-table91070_0ef94c-0c{table-layout:fixed;width:100%;}.kb-table-container .kb-table91070_0ef94c-0c th{padding-top:var(--global-kb-spacing-xxs, 0.5rem);padding-right:var(--global-kb-spacing-xxs, 0.5rem);padding-bottom:var(--global-kb-spacing-xxs, 0.5rem);padding-left:var(--global-kb-spacing-xxs, 0.5rem);text-align:center;}.kb-table-container .kb-table91070_0ef94c-0c caption{text-align:center;}.kb-table-container .kb-table91070_0ef94c-0c td{padding-top:var(--global-kb-spacing-xxs, 0.5rem);padding-right:var(--global-kb-spacing-xxs, 0.5rem);padding-bottom:var(--global-kb-spacing-xxs, 0.5rem);padding-left:var(--global-kb-spacing-xxs, 0.5rem);text-align:left;}.kb-table-container .kb-table91070_0ef94c-0c td, .kb-table91070_0ef94c-0c th{border-top:2px solid var(--global-palette3, #1A202C);border-right:2px solid var(--global-palette3, #1A202C);border-bottom:2px solid var(--global-palette3, #1A202C);border-left:2px solid var(--global-palette3, #1A202C);}@media all and (max-width: 1024px){.kb-table-container .kb-table91070_0ef94c-0c td, .kb-table91070_0ef94c-0c th{border-top:2px solid var(--global-palette3, #1A202C);border-right:2px solid var(--global-palette3, #1A202C);border-bottom:2px solid var(--global-palette3, #1A202C);border-left:2px solid var(--global-palette3, #1A202C);}}@media all and (max-width: 767px){.kb-table-container .kb-table91070_0ef94c-0c td, .kb-table91070_0ef94c-0c th{border-top:2px solid var(--global-palette3, #1A202C);border-right:2px solid var(--global-palette3, #1A202C);border-bottom:2px solid var(--global-palette3, #1A202C);border-left:2px solid var(--global-palette3, #1A202C);}}<\/style><div class=\"kb-table-container kb-table-container91070_0ef94c-0c wp-block-kadence-table\"><table class=\"kb-table kb-table91070_0ef94c-0c\">\n<tr class=\"kb-table-row kb-table-row91070_578aef-a3\">\n<th class=\"kb-table-data kb-table-data91070_d54f15-50\">\n\n<p class=\"has-theme-palette-3-color has-text-color has-link-color has-medium-font-size wp-elements-43efe35ca629b95600505d747263b69c\"><\/p>\n\n<\/th>\n\n<th class=\"kb-table-data kb-table-data91070_055edb-28\">\n\n<p class=\"has-text-color has-link-color has-medium-font-size wp-elements-204e11953ecf21d8f0afa91329fc3fa7\" style=\"color:#d02d87\">WCOT\u30ab\u30e9\u30e0<\/p>\n\n<\/th>\n\n<th class=\"kb-table-data kb-table-data91070_ae8eef-be\">\n\n<p class=\"has-theme-palette-1-color has-text-color has-link-color has-medium-font-size wp-elements-5bcb0180d1b085e699493adf0be864cc\">PLOT\u30ab\u30e9\u30e0<\/p>\n\n<\/th>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_d7d171-be\">\n<th class=\"kb-table-data kb-table-data91070_06dce2-50\">\n\n<p>\u6b63\u5f0f\u540d\u79f0<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_e7a1a6-78\">\n\n<p>Wall-Coated Open-Tubular<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_6914f4-6d\">\n\n<p>Porous-Layer Open-Tubular<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_ca1336-c0\">\n<th class=\"kb-table-data kb-table-data91070_82defc-9f\">\n\n<p>\u5206\u96e2\u30e1\u30ab\u30cb\u30ba\u30e0<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_3742b0-8b\">\n\n<p>\u6db2\u76f8\u3078\u306e \u300c<strong>\u5206\u914d<\/strong>\u300d<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_e27d7c-d8\">\n\n<p>\u591a\u5b54\u8cea\u8868\u9762\u3078\u306e \u300c<strong>\u5438\u7740<\/strong>\u300d<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_c234fc-10\">\n<th class=\"kb-table-data kb-table-data91070_47119d-c8\">\n\n<p>\u4fdd\u6301\u529b\u306e\u6307\u6a19<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_c5bbf8-21\">\n\n<p>\u76f8\u6bd4\uff08\u03b2\uff09\u3068\u819c\u539a\u306b\u4f9d\u5b58<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_7eb592-fa\">\n\n<p>\u5438\u7740\u5264\u306e\u8868\u9762\u76f8\u4e92\u4f5c\u7528\uff08WCOT\u306e\u7d04\u5341\u500d\uff09<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_d483ce-3c\">\n<th class=\"kb-table-data kb-table-data91070_d86aa1-65\">\n\n<p>\u5f97\u610f\u306a\u5206\u6790\u7a2e<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_821d02-c4\">\n\n<p>\u6cb8\u70b950\u2103\u301c450\u2103\u306e\u5316\u5408\u7269<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_43d513-8b\">\n\n<p>\u6cb8\u70b950\u2103\u672a\u6e80\u306e\u30ac\u30b9\u30fb\u63ee\u767a\u6027\u6210\u5206<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_ad807b-0c\">\n<th class=\"kb-table-data kb-table-data91070_6834f4-39\">\n\n<p>\u7269\u7406\u7684\u69cb\u9020<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_c2899d-dc\">\n\n<p>\u5e73\u6ed1\u306a\u5185\u58c1\u306b\u6db2\u76f8\u3092\u5857\u5e03<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_7e0514-3f\">\n\n<p>5\u301c50\u00b5m\u306e\u539a\u3044\u5438\u7740\u5264\u7c92\u5b50\u5c64\u3092\u56fa\u5b9a<\/p>\n\n<\/td>\n<\/tr>\n<\/table><\/div>\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji21\" style=\"font-size:38px;line-height:1.4\">2-1\uff0ePLOT\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\uff1a\u591a\u5b54\u8cea\u5438\u7740\u5264\u3068\u5206\u96e2\u539f\u7406<\/h2>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>\u8fd1\u5e74\u3001\u30ab\u30e9\u30e0\u306e\u9078\u629e\u6027\u306f\u3001Abraham\u3089\u306b\u3088\u3063\u3066\u63d0\u5531\u3055\u308c\u305f\u6eb6\u5a92\u548c\u30d1\u30e9\u30e1\u30fc\u30bf\u30e2\u30c7\u30eb\u306b\u57fa\u3065\u304f\u30b7\u30b9\u30c6\u30e0\u5b9a\u6570\uff08e,s,a,b,l\uff09\u306b\u3088\u3063\u3066\u8a73\u7d30\u306b\u7279\u6027\u8a55\u4fa1\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ul style=\"border-top-left-radius:20px;border-top-right-radius:20px;border-bottom-left-radius:20px;border-bottom-right-radius:20px\" class=\"wp-block-list\">\n<li style=\"margin-top:0;margin-right:var(--wp--preset--spacing--40);margin-bottom:0;margin-left:var(--wp--preset--spacing--40);padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">e\uff1a \u96fb\u5b50\u5b64\u7acb\u5bfe\uff08\u96fb\u5b50\uff09\u3068\u306e\u76f8\u4e92\u4f5c\u7528<\/li>\n\n\n\n<li style=\"margin-top:0;margin-right:var(--wp--preset--spacing--40);margin-bottom:0;margin-left:var(--wp--preset--spacing--40);padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">s\uff1a \u53cc\u6975\u5b50\uff0f\u5206\u6975\u6027\u76f8\u4e92\u4f5c\u7528<\/li>\n\n\n\n<li style=\"margin-top:0;margin-right:var(--wp--preset--spacing--40);margin-bottom:0;margin-left:var(--wp--preset--spacing--40);padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">a,b\uff1a \u6c34\u7d20\u7d50\u5408\u30c9\u30ca\u30fc\uff0f\u30a2\u30af\u30bb\u30d7\u30bf\u30fc\u6027<\/li>\n\n\n\n<li style=\"margin-top:0;margin-right:var(--wp--preset--spacing--40);margin-bottom:0;margin-left:var(--wp--preset--spacing--40);padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">l\uff1a \u5206\u6563\u76f8\u4e92\u4f5c\u7528\uff08\u7a7a\u6d1e\u5f62\u6210\u3068\u5206\u6563\u529b\u306e\u548c\uff09<\/li>\n<\/ul>\n\n\n\n<p>\u3053\u308c\u3089\u306e\u5b9a\u6570\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001PLOT\u30ab\u30e9\u30e0\u7279\u6709\u306e\u300c<strong>\u30b5\u30a4\u30ba\u6392\u9664<\/strong>\u300d\u300c<strong>\u5f37\u3044\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528<\/strong>\u300d\u300c<strong>\u8a98\u5c0e\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528<\/strong>\u300d\u3068\u3044\u3063\u305f\u8907\u96d1\u306a\u5438\u7740\u6319\u52d5\u3092\u7406\u8ad6\u7684\u306b\u4e88\u6e2c\u3057\u3001\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u629e\u3092\u884c\u3046\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/3-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u9078\u629e\u6027\u306e\u5b9a\u91cf\u7684\u8a55\u4fa1-1024x572.png\" alt=\"\" class=\"wp-image-91274\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/3-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u9078\u629e\u6027\u306e\u5b9a\u91cf\u7684\u8a55\u4fa1-1024x572.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/3-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u9078\u629e\u6027\u306e\u5b9a\u91cf\u7684\u8a55\u4fa1-300x168.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/3-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u9078\u629e\u6027\u306e\u5b9a\u91cf\u7684\u8a55\u4fa1-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/3-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u9078\u629e\u6027\u306e\u5b9a\u91cf\u7684\u8a55\u4fa1-1536x858.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/3-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u9078\u629e\u6027\u306e\u5b9a\u91cf\u7684\u8a55\u4fa1-2048x1144.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-medium-font-size\"><strong>\u4e3b\u8981\u306a\u76f8\u4e92\u4f5c\u7528\uff1a<\/strong><\/p>\n\n\n<style>.wp-block-kadence-iconlist.kt-svg-icon-list-items91070_8fe854-e2:not(.this-stops-third-party-issues){margin-top:0px;margin-bottom:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items91070_8fe854-e2 ul.kt-svg-icon-list:not(.this-prevents-issues):not(.this-stops-third-party-issues):not(.tijsloc){margin-top:0px;margin-right:0px;margin-bottom:var(--global-kb-spacing-sm, 1.5rem);margin-left:0px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items91070_8fe854-e2 ul.kt-svg-icon-list{grid-row-gap:30px;}.wp-block-kadence-iconlist.kt-svg-icon-list-items91070_8fe854-e2 ul.kt-svg-icon-list .kt-svg-icon-list-item-wrap .kt-svg-icon-list-single{margin-right:10px;}.kt-svg-icon-list-items91070_8fe854-e2 ul.kt-svg-icon-list .kt-svg-icon-list-level-0 .kt-svg-icon-list-single svg{font-size:20px;}<\/style>\n<div class=\"wp-block-kadence-iconlist kt-svg-icon-list-items kt-svg-icon-list-items91070_8fe854-e2 kt-svg-icon-list-columns-1 alignnone\"><ul class=\"kt-svg-icon-list\"><style>.kt-svg-icon-list-item-91070_c87eb5-3d .kt-svg-icon-list-single{font-size:50px !important;color:var(--global-palette2, #2B6CB0) !important;}.kt-svg-icon-list-item-91070_c87eb5-3d .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-91070_c87eb5-3d\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fas_thumbs-up kt-svg-icon-list-single\"><svg viewBox=\"0 0 512 512\"  fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M104 224H24c-13.255 0-24 10.745-24 24v240c0 13.255 10.745 24 24 24h80c13.255 0 24-10.745 24-24V248c0-13.255-10.745-24-24-24zM64 472c-13.255 0-24-10.745-24-24s10.745-24 24-24 24 10.745 24 24-10.745 24-24 24zM384 81.452c0 42.416-25.97 66.208-33.277 94.548h101.723c33.397 0 59.397 27.746 59.553 58.098.084 17.938-7.546 37.249-19.439 49.197l-.11.11c9.836 23.337 8.237 56.037-9.308 79.469 8.681 25.895-.069 57.704-16.382 74.757 4.298 17.598 2.244 32.575-6.148 44.632C440.202 511.587 389.616 512 346.839 512l-2.845-.001c-48.287-.017-87.806-17.598-119.56-31.725-15.957-7.099-36.821-15.887-52.651-16.178-6.54-.12-11.783-5.457-11.783-11.998v-213.77c0-3.2 1.282-6.271 3.558-8.521 39.614-39.144 56.648-80.587 89.117-113.111 14.804-14.832 20.188-37.236 25.393-58.902C282.515 39.293 291.817 0 312 0c24 0 72 8 72 81.452z\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\"><strong>\u30b5\u30a4\u30ba\u6392\u9664\uff08\u5206\u5b50\u3075\u308b\u3044\u52b9\u679c\uff09<\/strong>\uff1a \u4e3b\u306b\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6\uff08\u5408\u6210\u30bc\u30aa\u30e9\u30a4\u30c8\uff09\u306b\u898b\u3089\u308c\u308b\u6a5f\u69cb\u3067\u3059\u3002\u5438\u7740\u5264\u304c\u6301\u3064\u6570\u30aa\u30f3\u30b0\u30b9\u30c8\u30ed\u30fc\u30e0\u5358\u4f4d\u306e\u7d50\u6676\u5b66\u7684\u6709\u52b9\u7d30\u5b54\u5f84\u306b\u5bfe\u3057\u3001\u5206\u6790\u7a2e\u306e\u901f\u5ea6\u8ad6\u7684\u76f4\u5f84\uff08Kinetic Diameter\uff09\u304c\u5c0f\u3055\u3044\u5834\u5408\u3001\u5206\u5b50\u306f\u7d30\u5b54\u5185\u90e8\u3078\u9078\u629e\u7684\u306b\u6d78\u900f\u3057\u307e\u3059\u3002\u4e00\u65b9\u3001\u7d30\u5b54\u5f84\u3092\u4e0a\u56de\u308b\u30d0\u30eb\u30ad\u30fc\u306a\u5206\u5b50\uff08SF6\u3084\u30a4\u30bd\u30d6\u30bf\u30f3\u7b49\uff09\u306f\u6d78\u900f\u304c\u5236\u9650\u3055\u308c\u308b\u305f\u3081\u3001\u30b5\u30a4\u30ba\u6392\u9664\u306b\u3088\u3063\u3066\u65e9\u671f\u306b\u6eb6\u51fa\u3057\u307e\u3059\u3002\u3053\u306e\u7279\u6027\u306f\u3001\u6c38\u4e45\u30ac\u30b9\u7b49\u306e\u6975\u3081\u3066\u5fae\u5c0f\u306a\u5206\u5b50\u306e\u7cbe\u5bc6\u5206\u96e2\u306b\u304a\u3044\u3066\u652f\u914d\u7684\u306a\u5f79\u5272\u3092\u679c\u305f\u3057\u307e\u3059\u3002<\/span><\/li>\n\n\n<style>.kt-svg-icon-list-item-91070_4b6014-52 .kt-svg-icon-list-single{font-size:50px !important;color:var(--global-palette2, #2B6CB0) !important;}.kt-svg-icon-list-item-91070_4b6014-52 .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-91070_4b6014-52\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fas_thumbs-up kt-svg-icon-list-single\"><svg viewBox=\"0 0 512 512\"  fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M104 224H24c-13.255 0-24 10.745-24 24v240c0 13.255 10.745 24 24 24h80c13.255 0 24-10.745 24-24V248c0-13.255-10.745-24-24-24zM64 472c-13.255 0-24-10.745-24-24s10.745-24 24-24 24 10.745 24 24-10.745 24-24 24zM384 81.452c0 42.416-25.97 66.208-33.277 94.548h101.723c33.397 0 59.397 27.746 59.553 58.098.084 17.938-7.546 37.249-19.439 49.197l-.11.11c9.836 23.337 8.237 56.037-9.308 79.469 8.681 25.895-.069 57.704-16.382 74.757 4.298 17.598 2.244 32.575-6.148 44.632C440.202 511.587 389.616 512 346.839 512l-2.845-.001c-48.287-.017-87.806-17.598-119.56-31.725-15.957-7.099-36.821-15.887-52.651-16.178-6.54-.12-11.783-5.457-11.783-11.998v-213.77c0-3.2 1.282-6.271 3.558-8.521 39.614-39.144 56.648-80.587 89.117-113.111 14.804-14.832 20.188-37.236 25.393-58.902C282.515 39.293 291.817 0 312 0c24 0 72 8 72 81.452z\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\"><strong>\u6c38\u4e45\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\uff08\u9759\u96fb\u7684\u76f8\u4e92\u4f5c\u7528\uff09<\/strong>\uff1a \u30a2\u30eb\u30df\u30ca\uff08\u9178\u5316\u30a2\u30eb\u30df\u30cb\u30a6\u30e0\uff09\u7b49\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u3055\u308c\u305f\u7121\u6a5f\u5438\u7740\u5264\u3067\u898b\u3089\u308c\u308b\u6a5f\u69cb\u3067\u3059\u3002\u5438\u7740\u5264\u8868\u9762\u306e\u6d3b\u6027\u8868\u9762\u3068\u3001\u5206\u6790\u7a2e\u306e\u6975\u6027\u5b98\u80fd\u57fa\u3068\u306e\u9593\u3067\u751f\u3058\u308b\u9759\u96fb\u7684\u306a\u5f15\u529b\u3092\u5229\u7528\u3057\u307e\u3059\u3002\u3053\u306e\u76f8\u4e92\u4f5c\u7528\u306f\u6975\u3081\u3066\u5f37\u529b\u3067\u3042\u308a\u3001\u7279\u306b\u4e0d\u98fd\u548c\u70ad\u5316\u6c34\u7d20\uff08\u30a2\u30eb\u30b1\u30f3\u3001\u30a2\u30eb\u30ad\u30f3\uff09\u306e\u3088\u3046\u306a\u5206\u6975\u7387\u306e\u9ad8\u3044\u6210\u5206\u306b\u5bfe\u3057\u3001\u6cb8\u70b9\u9806\u306b\u4f9d\u5b58\u3057\u306a\u3044\u7279\u7570\u7684\u306a\u4fdd\u6301\u9078\u629e\u6027\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002Abraham\u30e2\u30c7\u30eb\u306b\u304a\u3051\u308b\u53cc\u6975\u5b50\u6027\uff0f\u5206\u6975\u6027\uff08s\uff09\u304a\u3088\u3073\u96fb\u5b50\u5b64\u7acb\u5bfe\u76f8\u4e92\u4f5c\u7528\uff08e\uff09\u306e\u5bc4\u4e0e\u304c\u5927\u304d\u304f\u53cd\u6620\u3055\u308c\u308b\u9818\u57df\u3067\u3059\u3002<\/span><\/li>\n\n\n<style>.kt-svg-icon-list-item-91070_d5e219-00 .kt-svg-icon-list-single{font-size:50px !important;color:var(--global-palette2, #2B6CB0) !important;}.kt-svg-icon-list-item-91070_d5e219-00 .kt-svg-icon-list-text mark.kt-highlight{background-color:unset;font-style:normal;color:#f76a0c;-webkit-box-decoration-break:clone;box-decoration-break:clone;padding-top:0px;padding-right:0px;padding-bottom:0px;padding-left:0px;}<\/style>\n<li class=\"wp-block-kadence-listitem kt-svg-icon-list-item-wrap kt-svg-icon-list-item-91070_d5e219-00\"><span class=\"kb-svg-icon-wrap kb-svg-icon-fas_thumbs-up kt-svg-icon-list-single\"><svg viewBox=\"0 0 512 512\"  fill=\"currentColor\" xmlns=\"http:\/\/www.w3.org\/2000\/svg\"  aria-hidden=\"true\"><path d=\"M104 224H24c-13.255 0-24 10.745-24 24v240c0 13.255 10.745 24 24 24h80c13.255 0 24-10.745 24-24V248c0-13.255-10.745-24-24-24zM64 472c-13.255 0-24-10.745-24-24s10.745-24 24-24 24 10.745 24 24-10.745 24-24 24zM384 81.452c0 42.416-25.97 66.208-33.277 94.548h101.723c33.397 0 59.397 27.746 59.553 58.098.084 17.938-7.546 37.249-19.439 49.197l-.11.11c9.836 23.337 8.237 56.037-9.308 79.469 8.681 25.895-.069 57.704-16.382 74.757 4.298 17.598 2.244 32.575-6.148 44.632C440.202 511.587 389.616 512 346.839 512l-2.845-.001c-48.287-.017-87.806-17.598-119.56-31.725-15.957-7.099-36.821-15.887-52.651-16.178-6.54-.12-11.783-5.457-11.783-11.998v-213.77c0-3.2 1.282-6.271 3.558-8.521 39.614-39.144 56.648-80.587 89.117-113.111 14.804-14.832 20.188-37.236 25.393-58.902C282.515 39.293 291.817 0 312 0c24 0 72 8 72 81.452z\"\/><\/svg><\/span><span class=\"kt-svg-icon-list-text\"><strong>\u8a98\u5c0e\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\uff08\u5206\u6975\u6027\u9078\u629e\u6027\uff09<\/strong>\uff1a \u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc\u7cfb\u5438\u7740\u5264\uff08\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\u9aa8\u683c\u7b49\uff09\u3067\u652f\u914d\u7684\u306a\u6a5f\u69cb\u3067\u3059\u3002\u30dd\u30ea\u30de\u30fc\u5185\u306e\u82b3\u9999\u65cf\u5b98\u80fd\u57fa\uff08\u30d5\u30a7\u30cb\u30eb\u57fa\u7b49\uff09\u304c\u5206\u6790\u7a2e\u3092\u4e00\u6642\u7684\u306b\u96fb\u5b50\u7684\u306b\u5206\u6975\u3055\u305b\u308b\u3053\u3068\u3067\u3001\u8a98\u5c0e\u53cc\u6975\u5b50\u3092\u5f62\u6210\u3057\u3001\u4fdd\u6301\u304c\u751f\u3058\u307e\u3059\u3002\u30a2\u30eb\u30df\u30ca\u7b49\u306e\u6c38\u4e45\u53cc\u6975\u5b50\u3068\u6bd4\u8f03\u3059\u308b\u3068\u76f8\u4e92\u4f5c\u7528\u529b\u81ea\u4f53\u306f\u7a4f\u3084\u304b\uff08Weaker interaction\uff09\u3067\u3059\u304c\u3001\u3053\u308c\u306b\u3088\u308a\u30a2\u30eb\u30b3\u30fc\u30eb\u3001\u30b1\u30c8\u30f3\u3001\u30a8\u30b9\u30c6\u30eb\u3068\u3044\u3063\u305f\u6975\u6027\u63ee\u767a\u6027\u5316\u5408\u7269\u3092\u30b7\u30e3\u30fc\u30d7\u306a\u30d4\u30fc\u30af\u5f62\u72b6\u3067\u5206\u96e2\u30fb\u6eb6\u51fa\u3055\u305b\u308b\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002<\/span><\/li>\n<\/ul><\/div>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji22\" style=\"font-size:38px;line-height:1.4\">2-2\uff0ePLOT\u30ab\u30e9\u30e0\u306e\u69cb\u9020\u7684\u7279\u7570\u6027\u3068\u5206\u96e2\u901f\u5ea6\u8ad6<\/h2>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>PLOT\u30ab\u30e9\u30e0\u306e\u7269\u7406\u7684\u672c\u8cea\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u5185\u58c1\u306b\u5f62\u6210\u3055\u308c\u305f5\uff5e50 \u00b5m\u306b\u53ca\u3076\u9ad8\u591a\u5b54\u8cea\u306a\u56fa\u4f53\u7c92\u5b50\u5c64\u306b\u96c6\u7d04\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u819c\u539a\u306f\u3001\u6a19\u6e96\u7684\u306a\u5206\u914d\u578b\uff08WCOT\uff09\u30ab\u30e9\u30e0\u306e\u6db2\u76f8\u819c\u539a\uff080.25 \u00b5m\uff5e1 \u00b5m\uff09\u3068\u6bd4\u8f03\u3057\u3066\u6570\u5341\u500d\u304b\u3089\u767e\u500d\u306e\u30b9\u30b1\u30fc\u30eb\u306b\u9054\u3057\u3001\u3053\u308c\u304c\u30ac\u30b9\u5206\u6790\u306b\u304a\u3044\u3066\u4ee5\u4e0b\u306e2\u3064\u306e\u901f\u5ea6\u8ad6\u7684\u30fb\u71b1\u529b\u5b66\u7684\u306a\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li style=\"padding-top:var(--wp--preset--spacing--20);padding-right:0;padding-bottom:var(--wp--preset--spacing--20);padding-left:0\"><strong>\u76f8\u6bd4\uff08\u03b2\uff09\u306e\u4f4e\u6e1b\u306b\u3088\u308b\u71b1\u529b\u5b66\u7684\u4fdd\u6301\u80fd\u306e\u5411\u4e0a<\/strong>\uff1a\u5185\u58c1\u306b\u6577\u304d\u8a70\u3081\u3089\u308c\u305f0.1\uff5e2 \u00b5m\u306e\u5fae\u7d30\u7c92\u5b50\uff08\u305d\u306e\u6570\u306f1 m\u3042\u305f\u308a1\u5146\u500b\u4ee5\u4e0a\uff09\u306f\u3001\u81a8\u5927\u306a\u6709\u52b9\u8868\u9762\u7a4d\u3092\u5275\u51fa\u3057\u307e\u3059\u3002\u3053\u306e\u69cb\u9020\u306f\u3001\u5438\u7740\u5264\u306e\u7a2e\u985e\u3084\u7d30\u5b54\u5f84\u3001\u6e29\u5ea6\u6761\u4ef6\u306b\u4f9d\u5b58\u3059\u308b\u3082\u306e\u306e\u3001\u5b9f\u7528\u7684\u306a\u30ac\u30b9\u5206\u6790\u6761\u4ef6\u4e0b\u3067\u306f\u3001\u79fb\u52d5\u76f8\u4f53\u7a4d\u3068\u56fa\u5b9a\u76f8\u4f53\u7a4d\u306e\u6bd4\u3067\u3042\u308b\u76f8\u6bd4\uff08\u03b2\uff09\u6570\u5341\u500d\u3068\u3044\u3046\u5727\u5012\u7684\u306a\u4fdd\u6301\u529b\u3092\u5b9f\u73fe\u3057\u307e\u3059\u3002\u3053\u306e\u5f37\u529b\u306a\u5438\u7740\u76f8\u4e92\u4f5c\u7528\u306b\u3088\u308a\u3001WCOT\u3067\u306f\u4fdd\u6301\u304c\u56f0\u96e3\u306a\u6c38\u4e45\u30ac\u30b9\u3084\u4f4e\u7d1a\u70ad\u5316\u6c34\u7d20\u306b\u5bfe\u3057\u3066\u3082\u3001\u5e38\u6e29\u3042\u308b\u3044\u306f\u5ba4\u6e29\u4ee5\u4e0a\u306e\u5236\u5fa1\u3057\u3084\u3059\u3044\u6e29\u5ea6\u9818\u57df\u3067\u3001\u5341\u5206\u306a\u5206\u96e2\u80fd\uff08Rs\uff09\u3092\u78ba\u4fdd\u3059\u308b\u3053\u3068\u304c\u53ef\u80fd\u3068\u306a\u308a\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u901f\u5ea6\u8ad6\u7684\u5236\u7d04\u3092\u53d7\u3051\u306b\u304f\u3044\u69cb\u9020<\/strong>\uff1a\u9ad8\u52b9\u7387\u3068\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u5bb9\u91cf\u306e\u4e21\u7acb\uff1aWCOT\u30ab\u30e9\u30e0\u306b\u304a\u3044\u3066\u3001\u9ad8\u63ee\u767a\u6027\u6210\u5206\u306e\u4fdd\u6301\u3092\u5f37\u3081\u308b\u305f\u3081\u306b\u6db2\u76f8\u819c\u539a\uff08df\uff09\u3092\u539a\u819c\u5316\uff081 \u00b5m\u4ee5\u4e0a\uff09\u3057\u305f\u5834\u5408\u3001\u56fa\u5b9a\u76f8\u5185\u3067\u306e\u5206\u6790\u7a2e\u306e\u62e1\u6563\u901f\u5ea6\u304c\u4f4e\u4e0b\u3057\u3066\u7269\u8cea\u79fb\u52d5\u62b5\u6297\uff08\uff23\u9805\uff09\u304c\u5897\u5927\u3057\u3001\u7406\u8ad6\u6bb5\u6570\uff08\uff2e\uff09\u306e\u6025\u6fc0\u306a\u4f4e\u4e0b\u3068\u3044\u3046\u30c8\u30ec\u30fc\u30c9\u30aa\u30d5\u304c\u751f\u3058\u307e\u3059\u3002 \u5bfe\u7167\u7684\u306b\u3001PLOT\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\u306f\u300c\u539a\u819c\u300d\u3067\u3042\u308a\u306a\u304c\u3089\u9ad8\u5ea6\u306b\u300c\u591a\u5b54\u8cea\u300d\u306a\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u3092\u5f62\u6210\u3057\u3066\u3044\u307e\u3059\u3002Giddings\u306e\u7406\u8ad6\u304c\u793a\u3059\u901a\u308a\u3001\u56fa\u5b9a\u76f8\u304c\u9ad8\u5ea6\u306b\u591a\u5b54\u8cea\u3067\u3042\u308c\u3070\u3001\u5c64\u5185\u3067\u306e\u5206\u5b50\u62e1\u6563\u306f\u79fb\u52d5\u76f8\u4e2d\u306b\u8fd1\u3044\u901f\u5ea6\u3067\u9032\u884c\u3057\u307e\u3059\u3002\u305d\u306e\u7d50\u679c\u3001\u7269\u8cea\u79fb\u52d5\u62b5\u6297\u3092\u6700\u5c0f\u9650\u306b\u6291\u5236\u3057\u3066\u9ad8\u3044\u7406\u8ad6\u6bb5\u6570\uff08\u5206\u96e2\u52b9\u7387\uff09\u3092\u7dad\u6301\u3057\u305f\u307e\u307e\u3001\u81a8\u5927\u306a\u8868\u9762\u7a4d\u306b\u7531\u6765\u3059\u308b\u5de8\u5927\u306a\u4fdd\u6301\u5bb9\u91cf\uff08\u30b5\u30f3\u30d7\u30eb\u8ca0\u8377\u91cf\uff09\u3092\u78ba\u4fdd\u3067\u304d\u308b\u306e\u3067\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u89e3\u8aac\u7de8\u7528-\u5727\u5012\u7684\u306a\u4fdd\u6301\u529b\u306e\u6e90\u6cc9-2-1024x572.png\" alt=\"\" class=\"wp-image-91300\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u89e3\u8aac\u7de8\u7528-\u5727\u5012\u7684\u306a\u4fdd\u6301\u529b\u306e\u6e90\u6cc9-2-1024x572.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u89e3\u8aac\u7de8\u7528-\u5727\u5012\u7684\u306a\u4fdd\u6301\u529b\u306e\u6e90\u6cc9-2-300x168.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u89e3\u8aac\u7de8\u7528-\u5727\u5012\u7684\u306a\u4fdd\u6301\u529b\u306e\u6e90\u6cc9-2-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u89e3\u8aac\u7de8\u7528-\u5727\u5012\u7684\u306a\u4fdd\u6301\u529b\u306e\u6e90\u6cc9-2-1536x858.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/1-\u89e3\u8aac\u7de8\u7528-\u5727\u5012\u7684\u306a\u4fdd\u6301\u529b\u306e\u6e90\u6cc9-2-2048x1144.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p>\u3053\u306e\u3088\u3046\u306b\u3001\u300c<strong>\u539a\u819c\u306b\u3088\u308b\u9ad8\u3044\u4fdd\u6301\u80fd<\/strong>\u300d\u3068\u300c<strong>\u591a\u5b54\u8cea\u69cb\u9020\u306b\u3088\u308b\u8fc5\u901f\u306a\u5206\u5b50\u79fb\u52d5<\/strong>\u300d\u3092\u9ad8\u5ea6\u306b\u4e21\u7acb\u3055\u305b\u305f\u7279\u7570\u306a\u30a2\u30fc\u30ad\u30c6\u30af\u30c1\u30e3\u3053\u305d\u304c\u3001PLOT\u30ab\u30e9\u30e0\u3092\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3051\u308b\u552f\u4e00\u7121\u4e8c\u306e\u7cbe\u5bc6\u30c7\u30d0\u30a4\u30b9\u3078\u3068\u62bc\u3057\u4e0a\u3052\u3066\u3044\u307e\u3059\u3002<\/p>\n<\/div>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji31\" style=\"font-size:38px;line-height:1.4\">3-1\uff0ePLOT\u56fa\u5b9a\u76f8\u306e\u5b89\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9<\/h2>\n\n\n\n<p>\u304b\u3064\u3066\u306ePLOT\u30ab\u30e9\u30e0\u306f\u3001\u7c92\u5b50\u304c\u5265\u304c\u308c\u3084\u3059\u3044\u300c<strong>\u4e0d\u5b89\u5b9a\u306a\u7c92\u5b50\u5c64<\/strong>\u300d\u304c\u8ab2\u984c\u3067\u3057\u305f\u3002 Restek\u306f\u72ec\u81ea\u306e\u56fa\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9\u3092\u958b\u767a\u3057\u3001\u300c<strong>\u7c92\u5b50\u5265\u96e2\uff08Particle shedding\uff09<\/strong>\u300d\u3092\u5b9f\u8cea\u7684\u306b\u6392\u9664\u3057\u305f\u6975\u3081\u3066\u5f37\u56fa\u306a\u56fa\u5b9a\u76f8\u3092\u5b9f\u73fe\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u30d0\u30eb\u30d6\u5207\u66ff\u6642\u306e\u6025\u6fc0\u306a\u5727\u529b\u5909\u52d5\u306b\u3082\u8010\u3048\u3001\u30b9\u30d1\u30a4\u30af\u30ce\u30a4\u30ba\u3084\u691c\u51fa\u5668\u306e\u6c5a\u67d3\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u308b\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji32\" style=\"font-size:38px;line-height:1.4\">3-2\uff0e\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\u5024\uff09\u3068\u518d\u73fe\u6027\u306e\u7ba1\u7406<\/h2>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>PLOT\u30ab\u30e9\u30e0\u306f\u56fa\u5b9a\u76f8\u304c\u539a\u3044\u305f\u3081\u3001\u5fae\u7d30\u306a\u4e0d\u5747\u4e00\u6027\u304c\u6d41\u91cf\u62b5\u6297\u306b\u76f4\u7d50\u3057\u3001\u5f93\u6765\u306f\u30ab\u30e9\u30e0\u4ea4\u63db\u6642\u306e\u4fdd\u6301\u6642\u9593\u306e\u30ba\u30ec\u304c\u5927\u304d\u306a\u8ab2\u984c\u3067\u3057\u305f\u3002Restek\u306f\u696d\u754c\u3067\u552f\u4e00\u3001\u54c1\u8cea\u7ba1\u7406\u6307\u6a19\u3068\u3057\u3066\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\u5024\uff09\u3092\u5c0e\u5165\u3057\u3001\u3053\u306e\u554f\u984c\u3092\u89e3\u6c7a\u3057\u307e\u3057\u305f\u3002<\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<ul class=\"wp-block-list\">\n<li><strong>F\u5024\u306e\u5b9a\u7fa9\u3068\u7b97\u51fa<\/strong>\uff1aF\u5024\u306f\u3001\u30ab\u30e9\u30e0\u5185\u90e8\u306e\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u5c64\u304c\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u306e\u6d41\u308c\u306b\u4e0e\u3048\u308b\u62b5\u6297\u3092\u6570\u5024\u5316\u3057\u305f\u3082\u306e\u3067\u3059\u3002\u4ee5\u4e0b\u306e\u5f0f\u3067\u7b97\u51fa\u3055\u308c\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p class=\"has-text-align-center has-larger-font-size\">\u3000\u3000\u3000        <strong>F \uff1d tR<sub>1<\/sub>\/tR<sub>2<\/sub><\/strong><\/p>\n\n\n\n<p class=\"has-medium-font-size\">\uff1c<strong>tR<sub>1<\/sub><\/strong>: \u975e\u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u30c1\u30e5\u30fc\u30d6\u306e\u4fdd\u6301\u6642\u9593, <strong>tR<sub>2<\/sub><\/strong>: \u30b3\u30fc\u30c6\u30a3\u30f3\u30b0\u5f8c\u306e\u30ab\u30e9\u30e0\u306e\u4fdd\u6301\u6642\u9593\uff1e<\/p>\n\n\n\n<p>\u7406\u60f3\u7684\u306a\u30aa\u30fc\u30d7\u30f3\u30c1\u30e5\u30fc\u30d6\uff08\u62b5\u6297\u30bc\u30ed\uff09\u3067\u306fF\u5024\u306f1\u3068\u306a\u308a\u307e\u3059\u304c\u3001\u539a\u3044\u591a\u5b54\u8cea\u5c64\u3092\u6301\u3064PLOT\u30ab\u30e9\u30e0\u3067\u306f\u901a\u5e380.2\u301c0.8\u7a0b\u5ea6\u306b\u306a\u308a\u307e\u3059\u3002<\/p>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u30ab\u30e9\u30e0\u4ea4\u63db\u6642\u306e\u518d\u73fe\u6027\u3078\u306e\u8ca2\u732e<\/strong>\uff1a\u5f93\u6765\u306e\u88fd\u9020\u65b9\u6cd5\u3067\u306fF\u5024\u306e\u30d0\u30e9\u30c4\u30ad\u304c\u5927\u304d\u304f\u3001\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u4ea4\u63db\u3059\u308b\u305f\u3073\u306b\u30e1\u30bd\u30c3\u30c9\u306e\u518d\u691c\u8a0e\u3084\u5207\u66ff\u30d0\u30eb\u30d6\u306e\u30bf\u30a4\u30df\u30f3\u30b0\u8abf\u6574\uff08Deans\u30b9\u30a4\u30c3\u30c1\u30f3\u30b0\u306a\u3069\uff09\u304c\u5fc5\u8981\u3067\u3057\u305f\u3002Restek\u306fF\u5024\u3092\u30ab\u30e9\u30e0\u6bce\u306b\u4e00\u5b9a\u306b\u5236\u5fa1\u3059\u308b\u72ec\u81ea\u6280\u8853\u3092\u78ba\u7acb\u3057\u3001\u300c\u65b0\u3057\u3044\u30ab\u30e9\u30e0\u306b\u4ea4\u63db\u3057\u3066\u3082\u3001\u6d41\u91cf\u8a2d\u5b9a\u3092\u5909\u3048\u305a\u306b\u540c\u3058\u4fdd\u6301\u6642\u9593\u304c\u5f97\u3089\u308c\u308b\u300d\u518d\u73fe\u6027\u3092\u5b9f\u73fe\u3057\u3066\u3044\u307e\u3059\u3002\u5168\u3066\u306ePLOT\u30ab\u30e9\u30e0\u306b\u306fF\u5024\u304c\u691c\u67fb\u30fb\u660e\u8a18\u3055\u308c\u305f\u5206\u6790\u8a3c\u660e\u66f8\uff08CoA\uff09\u304c\u6dfb\u4ed8\u3055\u308c\u3066\u304a\u308a\u3001\u30e6\u30fc\u30b6\u30fc\u306f\u6d41\u91cf\u5909\u52d5\u304c\u8a31\u3055\u308c\u306a\u3044\u7cbe\u5bc6\u306a\u5206\u6790\u73fe\u5834\u306b\u304a\u3044\u3066\u3082\u7d76\u5bfe\u7684\u306a\u5b89\u5fc3\u611f\u3092\u6301\u3063\u3066\u30ab\u30e9\u30e0\u4ea4\u63db\u3092\u884c\u3048\u307e\u3059\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u54c1\u8cea\u7ba1\u7406\u306e\u53d6\u308a\u7d44\u307f.png\" alt=\"\" class=\"wp-image-91313\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u54c1\u8cea\u7ba1\u7406\u306e\u53d6\u308a\u7d44\u307f.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u54c1\u8cea\u7ba1\u7406\u306e\u53d6\u308a\u7d44\u307f-300x169.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u54c1\u8cea\u7ba1\u7406\u306e\u53d6\u308a\u7d44\u307f-768x432.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji33\" style=\"font-size:38px;line-height:1.4\">3-3\uff0ePLOT\u30ab\u30e9\u30e0\u5206\u96e2\u306b\u304a\u3051\u308b\u300c\u6c34\u300d\u306e\u5f71\u97ff<\/h2>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p>\u5438\u7740\u5264\u306f\u6c34\u5206\u306b\u5bfe\u3057\u3066\u6975\u3081\u3066\u654f\u611f\u3067\u3042\u308a\u3001\u305d\u306e\u7ba1\u7406\u304c\u5206\u6790\u306e\u518d\u73fe\u6027\u3092\u5de6\u53f3\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u30e2\u30ec\u30ad\u30e5\u30e9\u30fc\u30b7\u30fc\u30d6 \/ \u30a2\u30eb\u30df\u30ca<\/strong>\uff1a \u5f37\u529b\u306a\u4e7e\u71e5\u5264\u3068\u3057\u3066\u6a5f\u80fd\u3059\u308b\u305f\u3081\u6c34\u5206\u3092\u5f37\u304f\u5438\u7740\u3057\u3001\u4fdd\u6301\u6642\u9593\u306e\u77ed\u7e2e\u3084\u611f\u5ea6\u4f4e\u4e0b\u3092\u62db\u304d\u307e\u3059\u3002\u5b89\u5b9a\u3057\u305f\u5206\u6790\u306b\u306f<strong>\u5b9a\u671f\u7684\u306a\u713c\u304d\u51fa\u3057<\/strong>\uff08\u30a2\u30eb\u30df\u30ca\uff1a200\u2103\u3001Msieve\uff1a300\u2103\uff09\u306b\u3088\u308b\u518d\u751f\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong>\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc<\/strong>\uff1a \u758e\u6c34\u6027\u304c\u9ad8\u304f\u3001\u6c34\u5206\u5b50\u306f\u5438\u7740\u3055\u308c\u305a\u306b\u30b7\u30e3\u30fc\u30d7\u306a\u30d4\u30fc\u30af\u3068\u3057\u3066\u8fc5\u901f\u306b\u6eb6\u51fa\u3059\u308b\u305f\u3081\u3001\u542b\u6c34\u8a66\u6599\u3067\u3082<strong>\u9023\u7d9a\u5206\u6790\u304c\u53ef\u80fd<\/strong>\u3067\u3059\u3002<\/li>\n<\/ul>\n<\/div>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"572\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/2-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u306e\u6700\u9069\u5316-1-1024x572.png\" alt=\"\" class=\"wp-image-91319\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/2-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u306e\u6700\u9069\u5316-1-1024x572.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/2-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u306e\u6700\u9069\u5316-1-300x168.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/2-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u306e\u6700\u9069\u5316-1-768x429.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/2-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u306e\u6700\u9069\u5316-1-1536x858.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/2-\u89e3\u8aac\u7de8\u7528-\u5206\u96e2\u306e\u6700\u9069\u5316-1-2048x1144.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji34\" style=\"font-size:38px;line-height:1.4\">3-4\uff0e\u4fdd\u6301\u4fc2\u6570\u3068\u6e29\u5ea6\u306e\u95a2\u4fc2\uff1a\u9078\u629e\u6027\u3078\u306e\u5f71\u97ff<\/h2>\n\n\n\n<p>\u30a2\u30eb\u30df\u30ca\u30ab\u30e9\u30e0\u7b49\u306e\u8868\u9762\u6975\u6027\u306f\u52d5\u4f5c\u6e29\u5ea6\u306b\u5f37\u304f\u4f9d\u5b58\u3057\u307e\u3059\u3002\u4f4e\u6e29\u307b\u3069\u8868\u9762\u6975\u6027\u304c\u5f37\u307e\u308b\u305f\u3081\u3001\u30a2\u30bb\u30c1\u30ec\u30f3\u3084\u30d7\u30ed\u30d1\u30b8\u30a8\u30f3\u306a\u3069\u306e\u4e0d\u98fd\u548c\u70ad\u5316\u6c34\u7d20\u306e\u4fdd\u6301\u304c\u98fd\u548c\u70ad\u5316\u6c34\u7d20\u306b\u6bd4\u3079\u3066\u76f8\u5bfe\u7684\u306b\u5f37\u307e\u308a\u307e\u3059\u3002\u6e29\u5ea6\u30d7\u30ed\u30b0\u30e9\u30e0\u306e\u8a2d\u8a08\u306f\u3001\u5358\u306a\u308b\u6642\u9593\u8abf\u6574\u3067\u306f\u306a\u304f\u3001\u6210\u5206\u9593\u306e\u9078\u629e\u6027\u3092\u5fae\u8abf\u6574\u3059\u308b\u305f\u3081\u306e\u6226\u7565\u7684\u624b\u6bb5\u3068\u306a\u308a\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji35\" style=\"font-size:38px;line-height:1.4\">3-5\uff0e\u6c4e\u7528\u30ab\u30e9\u30e0\uff3b\u57fa\u672c\u306e3\u9078\uff3d\u3068\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\uff3b\u5c02\u9580\u306e3\u9078\uff3d<\/h2>\n\n\n\n<p class=\"has-medium-font-size\"><strong>\u53c2\u7167\u60c5\u5831\uff1a<a href=\"https:\/\/www.restek.com\/global\/ja\/plot-chromatogram-library\" target=\"_blank\" rel=\"noreferrer noopener\">PLOT\u30ab\u30e9\u30e0\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30e9\u30a4\u30d6\u30e9\u30ea<\/a><\/strong><\/p>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-3d56b17b2a647da98a960fd2355015a9\" style=\"color:#2831eb;font-size:25px\"><strong>\u3010\u6c4e\u7528\u30ab\u30e9\u30e0\uff1a\u57fa\u672c\u306e3\u9078\u3011<\/strong><\/p>\n\n\n\n<p class=\"has-theme-palette-2-color has-pale-ocean-gradient-background has-text-color has-background has-link-color has-medium-font-size wp-elements-3cdbec44d2dfdb1360235310a5da3cd7\"><strong>\u30b1\u30fc\u30b91\uff5c\u6c38\u4e45\u30ac\u30b9\uff08H<sub>2<\/sub>, O<sub>2<\/sub>, N<sub>2<\/sub>, CO\uff09\u3084\u5e0c\u30ac\u30b9\u3092\u78ba\u5b9f\u306b\u5206\u96e2\u3057\u305f\u3044<\/strong><\/p>\n\n\n\n<p>\u25cf \u63a8\u5968\uff1a<strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19723\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Msieve 5A<\/a><\/strong>\uff08<a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Msieve-5A-6.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\"><em>\u3053\u306e\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/em><\/a>\uff09<br>\u25cf \u7279\u9577\uff1a \u30b5\u30a4\u30ba\u6392\u9664\u3068\u9759\u96fb\u5f15\u529b\u306b\u3088\u308a\u3001\u9178\u7d20\uff08O\u2082\uff09\u306f\u7a92\u7d20\uff08N\u2082\uff09\u3088\u308a\u5148\u306b\u6eb6\u51fa\u3057\u307e\u3059\u3002\u307e\u305f\u3001\u30a2\u30eb\u30b4\u30f3\u3068\u9178\u7d20\u306e\u5206\u96e2\u306f\u3001\u30ab\u30e9\u30e0\u6e29\u5ea6\u3092\u4f4e\u6e29\uff0827\u2103\u4ed8\u8fd1\uff09\u306b\u3059\u308b\u307b\u3069\u5411\u4e0a\u3057\u307e\u3059\u3002 \u5f37\u529b\u306a\u4e7e\u71e5\u5264\u3067\u3042\u308b\u305f\u3081\u6c34\u5206\u3092\u5f37\u304f\u5438\u7740\u3057\u3001\u4fdd\u6301\u6642\u9593\u306e\u77ed\u7e2e\u3092\u62db\u304d\u307e\u3059\u3002\u3057\u304b\u3057\u3001300\u2103\u30672\u6642\u9593\u306e\u713c\u304d\u51fa\u3057\u3092\u884c\u3046\u3053\u3068\u3067\u3001\u5b8c\u5168\u306b\u521d\u671f\u6027\u80fd\u3078\u518d\u751f\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1504\" height=\"835\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Msieve5A-\u4fee\u6b63\u6e08.png\" alt=\"\" class=\"wp-image-93454\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Msieve5A-\u4fee\u6b63\u6e08.png 1504w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Msieve5A-\u4fee\u6b63\u6e08-300x167.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Msieve5A-\u4fee\u6b63\u6e08-1024x569.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Msieve5A-\u4fee\u6b63\u6e08-768x426.png 768w\" sizes=\"auto, (max-width: 1504px) 100vw, 1504px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-theme-palette-2-color has-pale-ocean-gradient-background has-text-color has-background has-link-color has-medium-font-size wp-elements-50eb54e0d478e8efea90902888f5370e\"><strong>\u30b1\u30fc\u30b92\uff5c\u70ad\u5316\u6c34\u7d20\uff08C1\u301cC6\uff09\u306e\u7570\u6027\u4f53\u3092\u7cbe\u5bc6\u306b\u5206\u96e2\u3057\u305f\u3044<\/strong><\/p>\n\n\n\n<p>\u25cf \u63a8\u5968\uff1a<strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19775\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/a><\/strong>\uff08<em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-Na2SO4-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/a><\/em>\uff09\u307e\u305f\u306f<strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19776\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/KCl<\/a><\/strong>\uff08<em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-KCI-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/a><\/em>\uff09<br>\u25cf \u7279\u9577\uff1a \u6d3b\u6027\u3092\u7121\u6a5f\u5869\u3067\u30b3\u30f3\u30c8\u30ed\u30fc\u30eb\u3002Na2SO4\u306f\u6975\u6027\u4e0d\u98fd\u548c\u6210\u5206\u306b\u3001KCl\u306f\u4f4e\u6975\u6027\u98fd\u548c\u6210\u5206\u306e\u5206\u96e2\u306b\u6700\u9069\u3067\u3059\u3002\u6c34\u304c\u5438\u7740\u3059\u308b\u3068\u8868\u9762\u6975\u6027\u304c\u4f4e\u4e0b\u3057\u3001\u30a2\u30bb\u30c1\u30ec\u30f3\u3084\u30d7\u30ed\u30d1\u30b8\u30a8\u30f3\u306a\u3069\u306e\u4e0d\u98fd\u548c\u70ad\u5316\u6c34\u7d20\u306e\u4fdd\u6301\u304c\u8457\u3057\u304f\u65e9\u307e\u308a\u307e\u3059\u3002\u5b89\u5b9a\u3057\u305f\u5206\u6790\u306b\u306f\u5b9a\u671f\u7684\u306a200\u2103\u3067\u306e\u30b3\u30f3\u30c7\u30a3\u30b7\u30e7\u30cb\u30f3\u30b0\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u5206\u96e2.png\" alt=\"\" class=\"wp-image-91343\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u5206\u96e2.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u5206\u96e2-300x169.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u306e\u5206\u96e2-768x432.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-theme-palette-2-color has-pale-ocean-gradient-background has-text-color has-background has-link-color has-medium-font-size wp-elements-44ea3210ef6daaf57857343c07ba77c8\"><strong>\u30b1\u30fc\u30b93\uff5c\u6eb6\u5a92\u3084\u6c34\u5206\u3092\u542b\u3080\u30b5\u30f3\u30d7\u30eb\u3092\u6c4e\u7528\u7684\u306b\u5206\u6790\u3057\u305f\u3044<\/strong><\/p>\n\n\n\n<p>\u25cf \u63a8\u5968\uff1a<strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19744\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Q-BOND<\/a><\/strong>\uff08<em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Q-BOND-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/a><\/em>\uff09<br>\u25cf \u7279\u9577\uff1a \u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\uff08DVB\uff09\u3092\u9aa8\u683c\u3068\u3057\u3001\u5b98\u80fd\u57fa\uff08\u30d3\u30cb\u30eb\u30d4\u30ea\u30b8\u30f3\u7b49\uff09\u306e\u7a2e\u985e\u3067\u6975\u6027\u304c\u6c7a\u307e\u308a\u307e\u3059\uff08Q &lt; QS &lt; S &lt; U\u306e\u9806\u306b\u9ad8\u6975\u6027\uff09\u3002\u307e\u305f\u3001\u6700\u5927\u306e\u5229\u70b9\u306f\u300c\u758e\u6c34\u6027\u300d\u3067\u3059\u3002 \u6c34\u3092\u5438\u7740\u305b\u305a\u3001\u6c34\u81ea\u4f53\u3092\u30b7\u30e3\u30fc\u30d7\u306a\u30d4\u30fc\u30af\u3068\u3057\u3066\u6eb6\u51fa\u3055\u305b\u307e\u3059\u3002\u305d\u306e\u305f\u3081\u3001\u542b\u6c34\u30b5\u30f3\u30d7\u30eb\u3067\u3082\u30c0\u30a6\u30f3\u30bf\u30a4\u30e0\u306a\u3057\u3067\u9023\u7d9a\u5206\u6790\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Q-BOND-\u4e0d\u6d3b\u6027.png\" alt=\"\" class=\"wp-image-91349\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Q-BOND-\u4e0d\u6d3b\u6027.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Q-BOND-\u4e0d\u6d3b\u6027-300x169.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Q-BOND-\u4e0d\u6d3b\u6027-768x432.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-text-color has-link-color wp-elements-2817dba4d05883659db1832bbacf67df\" style=\"color:#2831eb;font-size:30px\"><strong>\u3010\u7279\u5b9a\u7528\u9014\uff1a\u5c02\u9580\u306e3\u9078\u3011<\/strong><\/p>\n\n\n\n<p class=\"has-theme-palette-9-color has-luminous-dusk-gradient-background has-text-color has-background has-link-color has-medium-font-size wp-elements-c081f5372a0f63abb9bcaecd4eba761c\"><strong>\u30b1\u30fc\u30b94\uff5c\u30d7\u30ed\u30d4\u30ec\u30f3\u4e2d\u306e\u5fae\u91cf\u4e0d\u7d14\u7269\uff08MAPD\uff09\u3092\u5b89\u5b9a\u3057\u3066\u6e2c\u308a\u305f\u3044<\/strong><\/p>\n\n\n\n<p>\u25cf \u63a8\u5968\uff1a<strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19781\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/MAPD<\/a><\/strong>\uff08<em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-MAPD-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/a><\/em>\uff09<br>\u25cf \u7279\u9577\uff1a \u901a\u5e38\u3001PLOT\u30ab\u30e9\u30e0\u306f\u4f4e\u6cb8\u70b9\u6210\u5206\u7528\u3068\u3055\u308c\u307e\u3059\u304c\u3001\u6e29\u5ea6\u3092\u4e0a\u6607\u3055\u305b\u308b\u3053\u3068\u3067\u9ad8\u6cb8\u70b9\u5316\u5408\u7269\u3092\u6eb6\u51fa\u3055\u305b\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002250\u2103\u307e\u3067\u306e\u9ad8\u6e29\u5bfe\u5fdc\u53ef\u80fd\u3068\u3057\u305f\u3053\u3068\u3068\u72ec\u81ea\u306e\u4e0d\u6d3b\u6027\u5316\u306b\u3088\u308a\u3001\u5f93\u6765\u306e\u8ab2\u984c\u3067\u3042\u3063\u305f\u4e0d\u98fd\u548c\u5316\u5408\u7269\u306e\u5fdc\u7b54\u5024\u5909\u52d5\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-MAPD.png\" alt=\"\" class=\"wp-image-91355\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-MAPD.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-MAPD-300x169.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-MAPD-768x432.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-theme-palette-9-color has-luminous-dusk-gradient-background has-text-color has-background has-link-color wp-elements-68e58dd73eee8799d135792a1e0abdc3\"><strong>\u30b1\u30fc\u30b95\uff5c\u70ad\u5316\u6c34\u7d20\u4e2d\u306e\u5fae\u91cf\u306aH<sub>2<\/sub>S\u3084COS\u3001\u30e1\u30eb\u30ab\u30d7\u30bf\u30f3\u3092\u691c\u51fa\u3057\u305f\u3044<\/strong><\/p>\n\n\n\n<p>\u25cf \u63a8\u5968\uff1a<strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19772\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-U-BOND<\/a><\/strong>\uff08<em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-U-BOND-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/a><\/em>\uff09<br>\u25cf \u7279\u9577\uff1a \u70ad\u5316\u6c34\u7d20\u30b9\u30c8\u30ea\u30fc\u30e0\u4e2d\u306e\u5fae\u91cf\u306a\u6975\u6027\u4e0d\u7d14\u7269\uff08\u30a2\u30bb\u30c1\u30ec\u30f3\u3001\u30e1\u30c1\u30eb\u30a2\u30bb\u30c1\u30ec\u30f3\u3001\u30d7\u30ed\u30d1\u30b8\u30a8\u30f3\u306a\u3069\uff09\u306e\u5206\u6790\u306b\u306f\u3001\u6700\u9069\u5316\u3055\u308c\u305f\u4e0d\u6d3b\u6027\u5316\u6280\u8853\u304c\u4e0d\u53ef\u6b20\u3067\u3059\u3002\u3053\u306e\u30ab\u30e9\u30e0\u306f\u3001\u9ad8\u3044\u4e0d\u6d3b\u6027\u5ea6\u3092\u6709\u3059\u308b\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc\uff08DVB\u9aa8\u683c\uff09\u306b\u30b8\u30d3\u30cb\u30eb\u30d9\u30f3\u30bc\u30f3\u30fb\u30a8\u30c1\u30ec\u30f3\u30b0\u30ea\u30b3\u30fc\u30eb\uff0f\u30b8\u30e1\u30c1\u30eb\u30a2\u30af\u30ea\u30ec\u30fc\u30c8\u3092\u7d44\u307f\u8fbc\u3093\u3060\u6700\u3082\u9ad8\u3044\u6975\u6027\u3092\u5b9f\u73fe\u3057\u3066\u3044\u308b\u305f\u3081\u3001\u8150\u98df\u6027\u786b\u9ec4\u5316\u5408\u7269\u3092\u30a8\u30bf\u30f3\u3084\u30d7\u30ed\u30d1\u30f3\u306e\u5927\u304d\u306a\u30d4\u30fc\u30af\u304b\u3089\u5b8c\u5168\u306b\u5206\u96e2\u3057\u307e\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc\u30ab\u30e9\u30e0\u306e\u7279\u9577.png\" alt=\"\" class=\"wp-image-91361\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc\u30ab\u30e9\u30e0\u306e\u7279\u9577.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc\u30ab\u30e9\u30e0\u306e\u7279\u9577-300x169.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/\u30dd\u30fc\u30e9\u30b9\u30dd\u30ea\u30de\u30fc\u30ab\u30e9\u30e0\u306e\u7279\u9577-768x432.png 768w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-theme-palette-9-color has-luminous-dusk-gradient-background has-text-color has-background has-link-color has-medium-font-size wp-elements-89c71773ee315d754f87159fdec22273\"><strong>\u30b1\u30fc\u30b96\uff5c\u30d5\u30ed\u30f3\u985e\uff08CFC\uff09\u306e\u9ad8\u7cbe\u5ea6\u306a\u54c1\u8cea\u7ba1\u7406\u304c\u5fc5\u8981<\/strong><\/p>\n\n\n\n<p>\u25cf \u63a8\u5968\uff1a<strong><a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19763\" target=\"_blank\" rel=\"noreferrer noopener\">Rt-Alumina BOND\/CFC<\/a><\/strong>\uff08<em><a href=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-CFC-3.xlsx\" target=\"_blank\" rel=\"noreferrer noopener\">\u3053\u306e\u30ab\u30e9\u30e0\u3092\u7528\u3044\u305f\u5206\u6790\u306e\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30e0\u30ea\u30b9\u30c8<\/a><\/em>\uff09<br>\u25cf \u7279\u9577\uff1a Restek\u72ec\u81ea\u306e\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\u306b\u3088\u308a\u30a2\u30eb\u30df\u30ca\u8868\u9762\u306e\u53cd\u5fdc\u6027\u3092\u6291\u3048\u3066\u304a\u308a\u3001\u591a\u304f\u306eCFC\u5316\u5408\u7269\u306b\u5bfe\u3057\u3066\u9ad8\u3044\u30d4\u30fc\u30af\u5bfe\u79f0\u6027\u3068\u512a\u308c\u305f\u518d\u73fe\u6027\u3092\u63d0\u4f9b\u3057\u307e\u3059\u3002CFC\u306b\u5bfe\u3059\u308b\u5f37\u529b\u306a\u4fdd\u6301\u529b\u3068\u9ad8\u3044\u8ca0\u8377\u5bb9\u91cf\u3092\u5099\u3048\u3001\u5e83\u7bc4\u56f2\u306e\u7570\u6027\u4f53\u3092\u5ba4\u6e29\u4ee5\u4e0a\u3067\u8fc5\u901f\u306b\u5206\u96e2\u304c\u53ef\u80fd\u3067\u3059\u3002<\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"582\" src=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-CFC-1-1024x582.png\" alt=\"\" class=\"wp-image-91379\" title=\"-\" srcset=\"https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-CFC-1-1024x582.png 1024w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-CFC-1-300x171.png 300w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-CFC-1-768x437.png 768w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-CFC-1-1536x873.png 1536w, https:\/\/discover.restek.com\/wp-content\/uploads\/Rt-Alumina-BOND-CFC-1-2048x1164.png 2048w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-medium-font-size\"><strong>PLOT\u30ab\u30e9\u30e0\u30fb\u30ea\u30d5\u30a1\u30ec\u30f3\u30b9\u30ac\u30a4\u30c9<\/strong><\/p>\n\n\n<style>.kb-table-container91070_70179e-41{overflow-x:auto;}.kb-table91070_70179e-41 td:nth-of-type(1), .kb-table91070_70179e-41 th:nth-of-type(1){width:40%;}.kb-table91070_70179e-41 td:nth-of-type(2), .kb-table91070_70179e-41 th:nth-of-type(2){width:40%;}.kb-table91070_70179e-41 td:nth-of-type(3), .kb-table91070_70179e-41 th:nth-of-type(3){width:20%;}.kb-table91070_70179e-41{table-layout:fixed;width:100%;}.kb-table-container .kb-table91070_70179e-41 th{padding-top:var(--global-kb-spacing-xxs, 0.5rem);padding-right:var(--global-kb-spacing-xxs, 0.5rem);padding-bottom:var(--global-kb-spacing-xxs, 0.5rem);padding-left:var(--global-kb-spacing-xxs, 0.5rem);text-align:center;}.kb-table-container .kb-table91070_70179e-41 caption{text-align:center;}.kb-table-container .kb-table91070_70179e-41 td{padding-top:var(--global-kb-spacing-xxs, 0.5rem);padding-right:var(--global-kb-spacing-xxs, 0.5rem);padding-bottom:var(--global-kb-spacing-xxs, 0.5rem);padding-left:var(--global-kb-spacing-xxs, 0.5rem);text-align:left;}.kb-table-container .kb-table91070_70179e-41 td, .kb-table91070_70179e-41 th{border-top:2px solid var(--global-palette4, #2D3748);border-right:2px solid var(--global-palette4, #2D3748);border-bottom:2px solid var(--global-palette4, #2D3748);border-left:2px solid var(--global-palette4, #2D3748);}@media all and (max-width: 1024px){.kb-table-container .kb-table91070_70179e-41 td, .kb-table91070_70179e-41 th{border-top:2px solid var(--global-palette4, #2D3748);border-right:2px solid var(--global-palette4, #2D3748);border-bottom:2px solid var(--global-palette4, #2D3748);border-left:2px solid var(--global-palette4, #2D3748);}}@media all and (max-width: 767px){.kb-table-container .kb-table91070_70179e-41 td, .kb-table91070_70179e-41 th{border-top:2px solid var(--global-palette4, #2D3748);border-right:2px solid var(--global-palette4, #2D3748);border-bottom:2px solid var(--global-palette4, #2D3748);border-left:2px solid var(--global-palette4, #2D3748);}}<\/style><div class=\"kb-table-container kb-table-container91070_70179e-41 wp-block-kadence-table\"><table class=\"kb-table kb-table91070_70179e-41\">\n<tr class=\"kb-table-row kb-table-row91070_b504ac-3a\">\n<th class=\"kb-table-data kb-table-data91070_b77542-14\">\n\n<p>Restek\u88fd\u54c1\u540d<\/p>\n\n<\/th>\n\n<th class=\"kb-table-data kb-table-data91070_638676-64\">\n\n<p>\u4e3b\u306a\u30a2\u30d7\u30ea\u30b1\u30fc\u30b7\u30e7\u30f3<\/p>\n\n<\/th>\n\n<th class=\"kb-table-data kb-table-data91070_231543-3f\">\n\n<p>\u4ed6\u793e\u76f8\u5f53\u54c1<\/p>\n\n<\/th>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_913115-d6\">\n<th class=\"kb-table-data kb-table-data91070_d567a3-4c\">\n\n<p>Rt-Msieve 5A<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_402b9c-3b\">\n\n<p>\u6c38\u4e45\u30ac\u30b9\uff08H<sub>2<\/sub>, O<sub>2<\/sub>, N<sub>2<\/sub>, CO\uff09\u3002\u7279\u306bCO\u306e\u30d4\u30fc\u30af\u5f62\u72b6\u306b\u512a\u308c\u308b\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_2e5e0c-41\">\n\n<p style=\"font-size:15px\">HP-PLOT Molesieve, CP-Molsieve 5A<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_48d8e0-07\">\n<th class=\"kb-table-data kb-table-data91070_99e031-ab\">\n\n<p>Rt-Alumina BOND\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_d9d8bf-22\">\n\n<p>C1\u301cC5\u70ad\u5316\u6c34\u7d20\u3001\u30a8\u30c1\u30ec\u30f3\u3001\u30d7\u30ed\u30d4\u30ec\u30f3\u7b49\u306e\u7d14\u5ea6\u5206\u6790\u3002\u6975\u6027\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_f16a2d-c0\">\n\n<p style=\"font-size:15px\">GS-Alumina, CP-Al<sub>2<\/sub>O<sub>3<\/sub>\/Na<sub>2<\/sub>SO<sub>4<\/sub><\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_acd507-5d\">\n<th class=\"kb-table-data kb-table-data91070_36c36d-3f\">\n\n<p>Rt-Alumina BOND\/KCl<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_e0b73e-22\">\n\n<p>C1\u301cC8\u70ad\u5316\u6c34\u7d20\u3002KCl\u4e0d\u6d3b\u6027\u5316\u306b\u3088\u308a\u4f4e\u6975\u6027\u3002\u6c34\u306e\u518d\u751f\u983b\u5ea6\u3092\u524a\u6e1b\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_e41654-f8\">\n\n<p style=\"font-size:15px\">HP-PLOT Al<sub>2<\/sub>O<sub>3<\/sub>, CP-Al<sub>2<\/sub>O<sub>3<\/sub>\/KCl<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_16a912-70\">\n<th class=\"kb-table-data kb-table-data91070_e3e52a-bf\">\n\n<p>Rt-Alumina BOND\/MAPD<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_735f67-ff\">\n\n<p>\u5fae\u91cf\u30e1\u30c1\u30eb\u30a2\u30bb\u30c1\u30ec\u30f3\u30fb\u30d7\u30ed\u30d1\u30b8\u30a8\u30f3\u306e\u5b89\u5b9a\u5206\u6790\u3002250\u2103\u5bfe\u5fdc\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_64578c-21\">\n\n<p style=\"font-size:15px\">Select Al<sub>2<\/sub>O<sub>3<\/sub> MAPD<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_d9a90d-ed\">\n<th class=\"kb-table-data kb-table-data91070_5b3243-23\">\n\n<p>Rt-Q-BOND<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_a3cbe1-68\">\n\n<p>100%DVB\u3002\u6eb6\u5a92\u3001CO<sub>2<\/sub>\u3001ppm\u30ec\u30d9\u30eb\u306e\u6c34\u3092\u542b\u3080\u8a66\u6599\u306e\u6c4e\u7528\u5206\u6790\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_9ab49b-50\">\n\n<p style=\"font-size:15px\">HP-PLOT Q, PoraBOND Q<\/p>\n\n<\/td>\n<\/tr>\n\n<tr class=\"kb-table-row kb-table-row91070_879e7d-5a\">\n<th class=\"kb-table-data kb-table-data91070_a48b7e-8d\">\n\n<p>Rt-U-BOND<\/p>\n\n<\/th>\n\n<td class=\"kb-table-data kb-table-data91070_511b99-db\">\n\n<p>\u6700\u9ad8\u6975\u6027\u3002\u70ad\u5316\u6c34\u7d20\u4e2d\u306e\u5fae\u91cf H<sub>2<\/sub>S, COS, \u30e1\u30eb\u30ab\u30d7\u30bf\u30f3 \u5206\u96e2\u3002<\/p>\n\n<\/td>\n\n<td class=\"kb-table-data kb-table-data91070_b452d6-37\">\n\n<p style=\"font-size:15px\">HP-PLOT U, CP-PoraBOND U<\/p>\n\n<\/td>\n<\/tr>\n<\/table><\/div>\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji4\" style=\"font-size:38px;line-height:1.4\">4\uff0e\u5805\u7262\u6027\u306e\u78ba\u4fdd\uff1a\u7c92\u5b50\u5265\u96e2\u5bfe\u7b56\u3068MS\u5206\u6790\u3078\u306e\u914d\u616e<\/h2>\n\n\n\n<p>Restek\u306f\u3001\u7c92\u5b50\u3092\u5185\u58c1\u306b\u5f37\u56fa\u306b\u7d50\u5408\u3055\u305b\u308b\u72ec\u81ea\u306e\u5b89\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9\u306b\u3088\u308a\u5265\u96e2\u3092\u5b9f\u8cea\u7684\u306b\u6392\u9664\u3057\u3066\u3044\u307e\u3059\u304c\u3001\u30d0\u30eb\u30d6\u5207\u66ff\u6642\u306e\u6025\u6fc0\u306a\u5727\u529b\u30d1\u30eb\u30b9\u3084\u6d41\u901f\u5909\u52d5\u306f\u3001\u5438\u7740\u5c64\u306b\u6d41\u4f53\u529b\u5b66\u7684\u306a\u885d\u6483\u3092\u4e0e\u3048\u3001\u5fae\u7d30\u7c92\u5b50\u306e\u8131\u843d\u3092\u62db\u304f\u6f5c\u5728\u7684\u30ea\u30b9\u30af\u3092\u6709\u3057\u307e\u3059\u3002\u3053\u308c\u306b\u5bfe\u3057\u3066Restek\u306f\u3001\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u5bfe\u7b56\u3092\u63d0\u4f9b\u3057\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<ul class=\"wp-block-list\">\n<li><strong>\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u306b\u3088\u308b\u7269\u7406\u7684\u6355\u6349\u3068\u88c5\u7f6e\u4fdd\u8b77<\/strong>\uff1a \u7279\u306b\u8cea\u91cf\u5206\u6790\u8a08\uff08MS\uff09\u306a\u3069\u306e\u9ad8\u771f\u7a7a\u4e0b\u3067\u4f5c\u52d5\u3059\u308b\u691c\u51fa\u5668\u3067\u306f\u3001\u30ab\u30e9\u30e0\u51fa\u53e3\u5074\u306e\u5727\u529b\u964d\u4e0b\uff08\u771f\u7a7a\u5f15\u304d\uff09\u306b\u3088\u308a\u7c92\u5b50\u304c\u5f15\u304d\u8fbc\u307e\u308c\u308b\u30ea\u30b9\u30af\u304c\u5897\u5927\u3057\u3001\u30b9\u30d1\u30a4\u30af\u30ce\u30a4\u30ba\u306e\u767a\u751f\u3084\u30a4\u30aa\u30f3\u6e90\u306e\u6c5a\u67d3\u3092\u62db\u304d\u307e\u3059\u3002Restek\u306f\u3001\u76f8\u88dc\u7684\u306a\u4fdd\u8b77\u30c7\u30d0\u30a4\u30b9\u3068\u3057\u3066\u3001\u30ab\u30e9\u30e0\u5f8c\u6bb5\u306b5\u301c15m\u306e\u6db2\u76f8\u5206\u914d\u578b\uff08WCOT\uff09\u30ab\u30e9\u30e0\uff08Rxi-1ms\u7b49\uff09\u3092\u63a5\u7d9a\u3059\u308b\u300c\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7\u300d\u306e\u904b\u7528\u3092\u63a8\u5968\u3057\u3066\u3044\u307e\u3059\u3002\u3053\u306e\u30c8\u30e9\u30c3\u30d7\u30ab\u30e9\u30e0\u5185\u306e\u8584\u3044\u6db2\u76f8\u819c\uff08PDMS\u7b49\uff09\u304c\u3001\u5265\u96e2\u3057\u305f\u7c92\u5b50\u3092\u30de\u30c8\u30ea\u30c3\u30af\u30b9\u5185\u306b\u7269\u7406\u7684\u306b\u30ad\u30e3\u30c3\u30c1\u3057\u3001\u691c\u51fa\u5668\u3078\u306e\u5230\u9054\u3092\u78ba\u5b9f\u306b\u963b\u6b62\u3057\u307e\u3059\u3002MS\u63a5\u7d9a\u6642\u306b\u306f\u3001\u3088\u308a\u78ba\u5b9f\u306a\u6355\u6349\u80fd\u529b\u3092\u78ba\u4fdd\u3059\u308b\u305f\u3081\u300115m\u4ee5\u4e0a\u306e\u9577\u5c3a\u306a\u30c8\u30e9\u30c3\u30d7\u306e\u4f7f\u7528\u304c\u63a8\u5968\u3055\u308c\u307e\u3059\u3002<\/li>\n\n\n\n<li><strong>\u4f4e\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u63a5\u7d9a\u6280\u8853\u306e\u91cd\u8981\u6027<\/strong>\uff1a PLOT\u30ab\u30e9\u30e0\u3068<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/19753\" target=\"_blank\" rel=\"noreferrer noopener\">\u30d1\u30fc\u30c6\u30a3\u30af\u30eb\u30c8\u30e9\u30c3\u30d7<\/a>\u306e\u63a5\u7d9a\u306b\u306f\u3001\u30c7\u30c3\u30c9\u30dc\u30ea\u30e5\u30fc\u30e0\u3092\u6700\u5c0f\u9650\u306b\u6291\u3048\u3001\u6d41\u8def\u306e\u4e0d\u6d3b\u6027\u3092\u7dad\u6301\u3059\u308b\u305f\u3081\u306b\u3001\u30ac\u30e9\u30b9\u88fd\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/20405\" target=\"_blank\" rel=\"noreferrer noopener\">Press-Tight\uff08\u30d7\u30ec\u30b9\u30bf\u30a4\u30c8\uff09\u30b3\u30cd\u30af\u30bf<\/a>\u306e\u4f7f\u7528\u304c\u6700\u9069\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u9ad8\u63ee\u767a\u6027\u6210\u5206\u306e\u30d4\u30fc\u30af\u62e1\u6563\u3092\u6291\u5236\u3057\u306a\u304c\u3089\u3001\u7c92\u5b50\u5265\u96e2\u5bfe\u7b56\u3092\u8b1b\u3058\u308b\u3053\u3068\u304c\u53ef\u80fd\u3067\u3059\u3002<\/li>\n\n\n\n<li><strong>\u91d1\u5c5e\u88fdMXT\u30ab\u30e9\u30e0<\/strong>\uff1a\u30d7\u30ed\u30bb\u30b9GC\u3084\u30d5\u30a3\u30fc\u30eb\u30c9\u88c5\u7f6e\u306a\u3069\u3001\u5c0f\u5f84\u5dfb\u304d\u306e\u5236\u9650\u3084\u885d\u6483\u3001\u6fc0\u3057\u3044\u6e29\u5ea6\u5909\u5316\u3092\u4f34\u3046\u904e\u9177\u306a\u904b\u7528\u74b0\u5883\u4e0b\u3067\u306f\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u306e\u8106\u6027\u304c\u30dc\u30c8\u30eb\u30cd\u30c3\u30af\u3068\u306a\u308a\u307e\u3059\u3002\u3053\u308c\u306b\u5bfe\u3057Restek\u306e<a href=\"https:\/\/www.restek.com\/global\/ja\/p\/70066\" target=\"_blank\" rel=\"noreferrer noopener\">\u91d1\u5c5e\u88fdMXT PLOT\u30ab\u30e9\u30e0<\/a>\u306f\u3001\u30b9\u30c6\u30f3\u30ec\u30b9\u92fc\u306e\u8868\u9762\u306b\u9ad8\u5ea6\u306a\u4e0d\u6d3b\u6027\u5316\u51e6\u7406\uff08Siltek\u51e6\u7406\uff09\u3092\u65bd\u3057\u305f\u57fa\u6750\u3092\u63a1\u7528\u3057\u3066\u3044\u307e\u3059\u3002 \u3053\u306e\u6280\u8853\u306b\u3088\u308a\u3001\u30d5\u30e5\u30fc\u30ba\u30c9\u30b7\u30ea\u30ab\u3068\u540c\u7b49\u306e\u512a\u308c\u305f\u4e0d\u6d3b\u6027\u5ea6\u3092\u7dad\u6301\u3057\u3064\u3064\u3001\u91d1\u5c5e\u7279\u6709\u306e\u5ef6\u6027\u3068\u6a5f\u68b0\u7684\u5805\u7262\u6027\u3092\u517c\u306d\u5099\u3048\u308b\u3053\u3068\u306b\u6210\u529f\u3057\u307e\u3057\u305f\u3002\u6700\u5c0f3.5\u30a4\u30f3\u30c1\u5f84\u306e\u72ed\u5c0f\u30b9\u30da\u30fc\u30b9\u3078\u306e\u8a2d\u7f6e\u3084\u3001\u9ad8\u5727\u30ad\u30e3\u30ea\u30a2\u30ac\u30b9\u306e\u5909\u52d5\u4e0b\u3067\u3082\u69cb\u9020\u7684\u5b8c\u5168\u6027\u3092\u7dad\u6301\u3067\u304d\u308b\u305f\u3081\u3001\u30dd\u30fc\u30bf\u30d6\u30eb\u88c5\u7f6e\u3084\u30aa\u30f3\u30b5\u30a4\u30c8\u5206\u6790\u306b\u304a\u3051\u308b\u4fe1\u983c\u6027\u3092\u5927\u5e45\u306b\u5411\u4e0a\u3055\u305b\u3066\u3044\u307e\u3059\u3002<\/li>\n<\/ul>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"mokuji5\" style=\"font-size:38px;line-height:1.4\">5\uff0e \u3055\u3044\u3054\u306b\uff1aPLOT\u30ab\u30e9\u30e0\u3092\u300c\u7406\u89e3\u3057\u3066\u4f7f\u3046\u300d\u305f\u3081\u306b<\/h2>\n\n\n\n<p>Restek\u3067\u306f\u3001\u56fa\u5b9a\u76f8\u306e\u5b89\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9\u3084\u518d\u73fe\u6027\u7ba1\u7406\u306b\u95a2\u3059\u308b\u53d6\u308a\u7d44\u307f\u3092\u901a\u3058\u3066\u3001PLOT\u30ab\u30e9\u30e0\u3092\u5f93\u6765\u306e\u300c\u6271\u3044\u306b\u6ce8\u610f\u3092\u8981\u3059\u308b\u7279\u6b8a\u306a\u30ab\u30e9\u30e0\u300d\u304b\u3089\u3001\u5b89\u5b9a\u3057\u305f\u6761\u4ef6\u3067\u904b\u7528\u53ef\u80fd\u306a\u5206\u96e2\u30ab\u30e9\u30e0\u3068\u3057\u3066\u6574\u5099\u3057\u3066\u304d\u307e\u3057\u305f\u3002<br>\u672c\u8a18\u4e8b\u3067\u306f\u3001\u5438\u7740\u30e1\u30ab\u30cb\u30ba\u30e0\u3084\u5206\u96e2\u901f\u5ea6\u8ad6\u3001\u56fa\u5b9a\u76f8\u306e\u5b89\u5b9a\u5316\u3001\u6c34\u5206\u3084\u6e29\u5ea6\u306e\u5f71\u97ff\u3068\u3044\u3063\u305f\u89b3\u70b9\u304b\u3089\u3001PLOT\u30ab\u30e9\u30e0\u5206\u96e2\u304c\u6210\u7acb\u3059\u308b\u80cc\u666f\u3092\u6574\u7406\u3057\u307e\u3057\u305f\u3002\u3053\u308c\u3089\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001PLOT\u30ab\u30e9\u30e0\u306f\u7d4c\u9a13\u7684\u306b\u6271\u3046\u5bfe\u8c61\u3067\u306f\u306a\u304f\u3001\u4fdd\u6301\u6319\u52d5\u3084\u9078\u629e\u6027\u3092\u8ad6\u7406\u7684\u306b\u6349\u3048\u3089\u308c\u308b\u5206\u6790\u30c4\u30fc\u30eb\u3068\u3057\u3066\u4f4d\u7f6e\u3065\u3051\u308b\u3053\u3068\u304c\u3067\u304d\u307e\u3059\u3002<br>\u3053\u306e\u3088\u3046\u306a\u5206\u96e2\u539f\u7406\u3084\u4fdd\u6301\u6319\u52d5\u306e\u7406\u89e3\u306b\u52a0\u3048\u3001\u5b9f\u969b\u306e\u30ab\u30e9\u30e0\u9078\u5b9a\u3084\u904b\u7528\u4e0a\u306e\u57fa\u672c\u7684\u306a\u78ba\u8a8d\u30dd\u30a4\u30f3\u30c8\u3092\u542b\u3081\u3066\u5168\u4f53\u50cf\u3092\u7c21\u6f54\u306b\u6574\u7406\u3057\u305f\u3044\u5834\u5408\u306f\u3001\u305c\u3072<a href=\"https:\/\/discover.restek.com\/ja\/blogs-ja\/jpsa-kp202603\/kiwami-2026-plot-column-introduction\" target=\"_blank\" rel=\"noreferrer noopener\">\u5165\u9580\u7de8<\/a>\u3082\u53c2\u7167\u3057\u3066\u307f\u3066\u304f\u3060\u3055\u3044\u3002<\/p>\n\n\n\n<p>\u672c\u7a3f\u306f\u3001Restek\u30a6\u30a7\u30d3\u30ca\u30fc\u3001Journal of Chromatography A\u3001\u304a\u3088\u3073LCGC International\u63b2\u8f09\u306e\u8ad6\u6587\u306b\u57fa\u3065\u304d\u69cb\u6210\u3055\u308c\u3066\u3044\u307e\u3059\u3002<\/p>\n\n\n\n<p class=\"has-small-font-size\"><strong><a href=\"#mokuji\">\u261d\u76ee\u6b21\u306b\u623b\u308b<\/a><\/strong><\/p>\n\n\n\n<div class=\"wp-block-group is-vertical is-layout-flex wp-container-core-group-is-layout-8cf370e7 wp-block-group-is-layout-flex\">\n<p> \u3010<strong>\u53c2\u7167\u6587\u732e\u3011<\/strong><\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li><em>Snyder, L. R., Kirkland, J. J., &amp; Dolan, J. W.<\/em>, &#8220;Introduction to Modern Liquid Chromatography&#8221;, 3rd ed., Wiley, 2010.<\/li>\n\n\n\n<li><em>Colin F. Poole<\/em>, &#8220;Update and expansion of a system constant database for open-tubular columns used in gas chromatography&#8221;, Journal of Chromatography A 1766 (2026) 466595.<\/li>\n\n\n\n<li><em>Zhenghua Ji , Ronald E. Majors, Edward J. Guthrie<\/em>, &#8220;Porous layer open-tubular capillary columns: preparations, applications and future directions&#8221;, Journal of Chromatography A, 842 (1999) 115\u2013142.<\/li>\n\n\n\n<li><em>David S. Bell<\/em>,&nbsp;<em>Robert E. Synovec<\/em>,&nbsp;<em>Lina Mikaliunaite<\/em>, &#8220;Application of Porous Layer Open Tubular Columns \u2013 Beyond Permanent Gases&#8221;, The State of The Art in Life Science | The Future of Mass Spectrometry | Advances in Gas Chromatography, Advertisement | Articles | October 1, 2022.<\/li>\n\n\n\n<li><em>Katarina Oden<\/em>,&nbsp;<em>Jaap de Zeeuw<\/em>, &#8220;Effects of Water on Adsorbents in Porous Layer Open Tubular (PLOT) Column Gas Chromatography&#8221;, The State of The Art in Life Science | The Future of Mass Spectrometry | Advances in Gas Chromatography, Advertisement | Articles | June 1, 2021.<\/li>\n<\/ol>\n<\/div>\n","protected":false},"excerpt":{"rendered":"<p>PLOT\u30ab\u30e9\u30e0\u306f\u300c\u306a\u305c\u6c38\u4e45\u30ac\u30b9\u3092\u4fdd\u6301\u3067\u304d\u308b\u306e\u304b\uff1f\u300d\u3053\u306e\u554f\u3044\u306b\u5bfe\u3059\u308b\u7b54\u3048\u306f\u3001\u5358\u306a\u308b\u69cb\u9020\u8aac\u660e\u3067\u306f\u306a\u304f\u3001\u5438\u7740\u30e1\u30ab\u30cb\u30ba\u30e0\u30fb\u5206\u96e2\u901f\u5ea6\u8ad6\u30fb\u71b1\u529b\u5b66\u7684\u76f8\u4e92\u4f5c\u7528\u306e\u7406\u89e3\u306b\u3042\u308a\u307e\u3059\u3002\u672c\u8a18\u4e8b\u3067\u306f\u3001Abraham\u6eb6\u5a92\u548c\u30d1\u30e9\u30e1\u30fc\u30bf\u30e2\u30c7\u30eb\u3001\u76f8\u6bd4\uff08\u03b2\uff09\u3068\u4fdd\u6301\u6642\u9593\u306e\u95a2\u4fc2\u3001\u6e29\u5ea6\u4f9d\u5b58\u6027\u3001\u6c34\u5206\u306e\u71b1\u529b\u5b66\u7684\u5f71\u97ff\u3001\u305d\u3057\u3066Restek\u304c\u5c0e\u5165\u3057\u305f\u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\u5024\uff09\u306b\u3088\u308b\u518d\u73fe\u6027\u7ba1\u7406\u307e\u3067\u3001\u7406\u8ad6\u7684\u80cc\u666f\u304b\u3089\u4f53\u7cfb\u7684\u306b\u89e3\u8aac\u3057\u307e\u3059\u3002 \u5165\u9580\u7de8\u304c\u300c\u9078\u3073\u65b9\u30fb\u4f7f\u3044\u65b9\u300d\u3067\u3042\u308b\u306e\u306b\u5bfe\u3057\u3001\u672c\u7a3f\u306f\u300c\u306a\u305c\u305d\u3046\u306a\u308b\u306e\u304b\u300d\u3092\u7406\u89e3\u3059\u308b\u305f\u3081\u306e\u3088\u308a\u5c02\u9580\u7684\u306a\u89e3\u8aac\u7de8\u3067\u3059\u3002 \u25ce\u76ee\u6b21 1-1. GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\uff1aPacked Column\u304b\u3089Open Tubular Column\u30781-2. Open Tubular Column\u306e3\u3064\u306e\u57fa\u672c\u69cb\u9020\u3068\u7269\u7406\u6a5f\u69cb 2-1. PLOT\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\uff1a\u591a\u5b54\u8cea\u5438\u7740\u5264\u3068\u5206\u96e2\u539f\u74062-2. PLOT\u30ab\u30e9\u30e0\u306e\u69cb\u9020\u7684\u7279\u7570\u6027\u3068\u5206\u96e2\u901f\u5ea6\u8ad6 3-1. PLOT\u56fa\u5b9a\u76f8\u306e\u5b89\u5b9a\u5316\u30d7\u30ed\u30bb\u30b93-2. \u6d41\u91cf\u62b5\u6297\u4fc2\u6570\uff08F\u5024\uff09\u3068\u518d\u73fe\u6027\u306e\u7ba1\u74063-3. PLOT\u30ab\u30e9\u30e0\u5206\u96e2\u306b\u304a\u3051\u308b\u300c\u6c34\u300d\u306e\u5f71\u97ff3-4. \u4fdd\u6301\u4fc2\u6570\u3068\u6e29\u5ea6\u306e\u95a2\u4fc2\uff1a\u9078\u629e\u6027\u3078\u306e\u5f71\u97ff3-5. \u6c4e\u7528\u30ab\u30e9\u30e0\uff3b\u57fa\u672c\u306e3\u9078\uff3d\u3068\u7279\u5b9a\u7528\u9014\u30ab\u30e9\u30e0\uff3b\u5c02\u9580\u306e3\u9078\uff3d 4. \u5805\u7262\u6027\u306e\u8ffd\u6c42\uff1a\u7c92\u5b50\u5265\u96e2\u5bfe\u7b56\u3068MS\u5206\u6790\u306e\u6700\u9069\u5316 5. \u3055\u3044\u3054\u306b\uff1aPLOT\u30ab\u30e9\u30e0\u3092\u300c\u7406\u89e3\u3057\u3066\u4f7f\u3046\u300d\u305f\u3081\u306b 1-1. GC\u30ab\u30e9\u30e0\u306e\u9032\u5316\uff1aPacked Column\u304b\u3089Open Tubular Column\u3078 GC\u5206\u96e2\u306e\u6b74\u53f2\u306f\u3001\u7c89\u672b\u72b6\u306e\u56fa\u5b9a\u76f8\u3092\u30c1\u30e5\u30fc\u30d6\u5185\u306b\u8a70\u3081\u8fbc\u3093\u3060\u5145\u586b\u30ab\u30e9\u30e0\uff08Packed Column\uff09\u304b\u3089\u59cb\u307e\u308a\u307e\u3057\u305f\u304c\u3001\u305d\u306e\u5f8c\u306e\u30aa\u30fc\u30d7\u30f3\u30c1\u30e5\u30d6\u30e9\uff08Open Tubular: OT\uff09\u30ab\u30e9\u30e0\u306e\u767b\u5834\u306f\u3001\u5206\u96e2\u79d1\u5b66\u306b\u5927\u304d\u306a\u5909\u5316\u3092\u3082\u305f\u3089\u3057\u307e\u3057\u305f\u3002OT\u30ab\u30e9\u30e0\u306f\u3001\u30c1\u30e5\u30fc\u30d6\u4e2d\u592e\u306b\u969c\u5bb3\u7269\u306e\u306a\u3044\u300c\u958b\u53e3\u6d41\u8def\u300d\u3092\u6301\u3064\u69cb\u9020\u304c\u6700\u5927\u306e\u7279\u5fb4\u3067\u3059\u3002\u3053\u308c\u306b\u3088\u308a\u3001\u5f93\u6765\u306e\u5145\u586b\u30ab\u30e9\u30e0\u3068\u6bd4\u8f03\u3057\u3066\u4ee5\u4e0b\u306e\u3088\u3046\u306a\u30e1\u30ea\u30c3\u30c8\u3092\u4eab\u53d7\u3067\u304d\u307e\u3059\u3002 \u261d\u76ee\u6b21\u306b\u623b\u308b 1-2. Open Tubular Column\u306e3\u3064\u306e\u57fa\u672c\u69cb\u9020\u3068\u5206\u96e2\u6a5f\u69cb \u73fe\u5728\u3001OT\u30ab\u30e9\u30e0\u306f\u305d\u306e\u69cb\u9020\u306b\u3088\u308a\u4e3b\u306b\u4ee5\u4e0b\u306e3\u3064\u306b\u5927\u5225\u3055\u308c\u307e\u3059\u3002 WCOT\u30ab\u30e9\u30e0\u3068PLOT\u30ab\u30e9\u30e0\u306e\u6bd4\u8f03 \u261d\u76ee\u6b21\u306b\u623b\u308b 2-1\uff0ePLOT\u30ab\u30e9\u30e0\u306e\u56fa\u5b9a\u76f8\uff1a\u591a\u5b54\u8cea\u5438\u7740\u5264\u3068\u5206\u96e2\u539f\u7406 \u8fd1\u5e74\u3001\u30ab\u30e9\u30e0\u306e\u9078\u629e\u6027\u306f\u3001Abraham\u3089\u306b\u3088\u3063\u3066\u63d0\u5531\u3055\u308c\u305f\u6eb6\u5a92\u548c\u30d1\u30e9\u30e1\u30fc\u30bf\u30e2\u30c7\u30eb\u306b\u57fa\u3065\u304f\u30b7\u30b9\u30c6\u30e0\u5b9a\u6570\uff08e,s,a,b,l\uff09\u306b\u3088\u3063\u3066\u8a73\u7d30\u306b\u7279\u6027\u8a55\u4fa1\u3055\u308c\u3066\u3044\u307e\u3059\u3002 \u3053\u308c\u3089\u306e\u5b9a\u6570\u3092\u7406\u89e3\u3059\u308b\u3053\u3068\u3067\u3001PLOT\u30ab\u30e9\u30e0\u7279\u6709\u306e\u300c\u30b5\u30a4\u30ba\u6392\u9664\u300d\u300c\u5f37\u3044\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\u300d\u300c\u8a98\u5c0e\u53cc\u6975\u5b50\u76f8\u4e92\u4f5c\u7528\u300d\u3068\u3044\u3063\u305f\u8907\u96d1\u306a\u5438\u7740\u6319\u52d5\u3092\u7406\u8ad6\u7684\u306b\u4e88\u6e2c\u3057\u3001\u6700\u9069\u306a\u30ab\u30e9\u30e0\u9078\u629e\u3092\u884c\u3046\u3053\u3068\u304c\u53ef\u80fd\u306b\u306a\u308a\u307e\u3059\u3002 \u4e3b\u8981\u306a\u76f8\u4e92\u4f5c\u7528\uff1a \u261d\u76ee\u6b21\u306b\u623b\u308b 2-2\uff0ePLOT\u30ab\u30e9\u30e0\u306e\u69cb\u9020\u7684\u7279\u7570\u6027\u3068\u5206\u96e2\u901f\u5ea6\u8ad6 PLOT\u30ab\u30e9\u30e0\u306e\u7269\u7406\u7684\u672c\u8cea\u306f\u3001\u30ad\u30e3\u30d4\u30e9\u30ea\u30fc\u5185\u58c1\u306b\u5f62\u6210\u3055\u308c\u305f5\uff5e50 \u00b5m\u306b\u53ca\u3076\u9ad8\u591a\u5b54\u8cea\u306a\u56fa\u4f53\u7c92\u5b50\u5c64\u306b\u96c6\u7d04\u3055\u308c\u307e\u3059\u3002\u3053\u306e\u819c\u539a\u306f\u3001\u6a19\u6e96\u7684\u306a\u5206\u914d\u578b\uff08WCOT\uff09\u30ab\u30e9\u30e0\u306e\u6db2\u76f8\u819c\u539a\uff080.25 \u00b5m\uff5e1 \u00b5m\uff09\u3068\u6bd4\u8f03\u3057\u3066\u6570\u5341\u500d\u304b\u3089\u767e\u500d\u306e\u30b9\u30b1\u30fc\u30eb\u306b\u9054\u3057\u3001\u3053\u308c\u304c\u30ac\u30b9\u5206\u6790\u306b\u304a\u3044\u3066\u4ee5\u4e0b\u306e2\u3064\u306e\u901f\u5ea6\u8ad6\u7684\u30fb\u71b1\u529b\u5b66\u7684\u306a\u30d6\u30ec\u30fc\u30af\u30b9\u30eb\u30fc\u3092\u3082\u305f\u3089\u3057\u307e\u3059\u3002 \u3053\u306e\u3088\u3046\u306b\u3001\u300c\u539a\u819c\u306b\u3088\u308b\u9ad8\u3044\u4fdd\u6301\u80fd\u300d\u3068\u300c\u591a\u5b54\u8cea\u69cb\u9020\u306b\u3088\u308b\u8fc5\u901f\u306a\u5206\u5b50\u79fb\u52d5\u300d\u3092\u9ad8\u5ea6\u306b\u4e21\u7acb\u3055\u305b\u305f\u7279\u7570\u306a\u30a2\u30fc\u30ad\u30c6\u30af\u30c1\u30e3\u3053\u305d\u304c\u3001PLOT\u30ab\u30e9\u30e0\u3092\u9ad8\u63ee\u767a\u6027\u5316\u5408\u7269\u5206\u6790\u306b\u304a\u3051\u308b\u552f\u4e00\u7121\u4e8c\u306e\u7cbe\u5bc6\u30c7\u30d0\u30a4\u30b9\u3078\u3068\u62bc\u3057\u4e0a\u3052\u3066\u3044\u307e\u3059\u3002 \u261d\u76ee\u6b21\u306b\u623b\u308b 3-1\uff0ePLOT\u56fa\u5b9a\u76f8\u306e\u5b89\u5b9a\u5316\u30d7\u30ed\u30bb\u30b9 \u304b\u3064\u3066\u306ePLOT\u30ab\u30e9\u30e0\u306f\u3001\u7c92\u5b50\u304c\u5265\u304c\u308c\u3084\u3059\u3044\u300c\u4e0d\u5b89\u5b9a\u306a\u7c92\u5b50\u5c64\u300d\u304c\u8ab2\u984c\u3067\u3057\u305f\u3002&#8230;<\/p>\n","protected":false},"author":11,"featured_media":88777,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_kad_blocks_custom_css":"","_kad_blocks_head_custom_js":"","_kad_blocks_body_custom_js":"","_kad_blocks_footer_custom_js":"","_kadence_starter_templates_imported_post":false,"_kad_post_transparent":"","_kad_post_title":"","_kad_post_layout":"","_kad_post_sidebar_id":"","_kad_post_content_style":"","_kad_post_vertical_padding":"","_kad_post_feature":"","_kad_post_feature_position":"","_kad_post_header":false,"_kad_post_footer":false,"footnotes":""},"categories":[794],"tags":[],"industries-application":[],"post-badge":[],"resource-type":[],"product-library":[],"resource-technique":[2340],"ppma_author":[414],"class_list":["post-91070","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blogs-ja","resource-technique-gas-chromatography-gc-ja"],"acf":[],"taxonomy_info":{"category":[{"value":794,"label":"Blogs"}],"resource-technique":[{"value":2340,"label":"\u30ac\u30b9\u30af\u30ed\u30de\u30c8\u30b0\u30e9\u30d5\u30a3\u30fc"}]},"featured_image_src_large":["https:\/\/discover.restek.com\/wp-content\/uploads\/kiwami_base_v1-1024x535.png",1024,535,true],"author_info":{"display_name":"Restek Corporation","author_link":"https:\/\/discover.restek.com\/ja\/author\/restek-corporation\/"},"comment_info":0,"category_info":[{"term_id":794,"name":"Blogs","slug":"blogs-ja","term_group":0,"term_taxonomy_id":794,"taxonomy":"category","description":"","parent":0,"count":441,"filter":"raw","cat_ID":794,"category_count":441,"category_description":"","cat_name":"Blogs","category_nicename":"blogs-ja","category_parent":0}],"tag_info":false,"authors":[{"term_id":414,"user_id":11,"is_guest":0,"slug":"restek-corporation","display_name":"Restek Corporation","avatar_url":{"url":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg","url2x":"https:\/\/discover.restek.com\/wp-content\/uploads\/Restek_Favicon_300x300.jpg"},"0":null,"1":"","2":"","3":"","4":"","5":"","6":"","7":"","8":""}],"_links":{"self":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/91070","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/users\/11"}],"replies":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/comments?post=91070"}],"version-history":[{"count":14,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/91070\/revisions"}],"predecessor-version":[{"id":93461,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/posts\/91070\/revisions\/93461"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media\/88777"}],"wp:attachment":[{"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/media?parent=91070"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/categories?post=91070"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/tags?post=91070"},{"taxonomy":"industries-application","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/industries-application?post=91070"},{"taxonomy":"post-badge","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/post-badge?post=91070"},{"taxonomy":"resource-type","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-type?post=91070"},{"taxonomy":"product-library","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/product-library?post=91070"},{"taxonomy":"resource-technique","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/resource-technique?post=91070"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/discover.restek.com\/ja\/wp-json\/wp\/v2\/ppma_author?post=91070"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}